0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
EC2B-B21B011N2-U

EC2B-B21B011N2-U

  • 厂商:

    IDEC

  • 封装:

  • 描述:

    IDEC - EC2B-B21B011N2-U - HAZARDOUS LOCATION CTRL BOX/1HOLE X 1COL

  • 数据手册
  • 价格&库存
EC2B-B21B011N2-U 数据手册
EU2B Series: 30mm Hazardous Location Switches EC2B Series: Hazardous Location Control Stations PRODUCT DESCRIPTION Complying with UL, IECEX, and ATEX Directives for hazardous environments, new 30mm EU2B Hazardous Location Switches and EC2B Hazardous Location Control Stations provide increased safety for your applications. Control Unit Options: • Pushbuttons • Pilot Lights • Selector Switches • Key Selector Switches STANDARDS COMPLIANCE Switches Pilot Lights Class I, Zone 1, Ex de IIC T6 Gb Class I, Div 2, Groups A, B, C and D Class I, Zone 1 AEx d e IIC T6 Gb Class I Div 2, Groups A, B, C and D Class I, Zone 1, Ex de IIB T6 Gb Class I, Zone 1, Ex de IIC T6 Gb Class I, Div 2, Groups C and D Class I, Div 2, Groups A, B, C and D UL c-UL II2G Ex de IIC ATEX II2D tD A21 IP65 ECEx PTB 15.0006U IECEx PTB 15.0007U IECEX Meters Control Boxes II2G Ex de IIC Gb Ex d e IIC T6 Gb II2D Ex tb IIIC Db Ex tb IIIC T80ºC Db (dust) IP65 Ex de IIC T6 Gb Ex tb IIIC T80ºC Db (dust) ATEX PTB 08 ATEX 1053 U PTB 08 ATEX 1003 U PTB 08 ATEX 1048 Standards • Custom-configured stations • Open control boxes • Mounting holes for up to 18 control units • UL Type 4X rated • Up to 3 contact blocks Mark • Selector switches available with lever or key • Selector switches available with overlapping contacts UL60079-0 UL60079-1 UL60079-7 • Exposed and finger-safe (IP20) screw terminals available CAN/CSA C22.2 No. 60079-0 CAN/CSA C22.2 No. 60079-1 CAN/CSA C22.2 No. 60079-7 EN60079-0 EN60079-1 EN60079-7 EN60079-31 • Corrosion resistant stainless steel enclosure (SUS304) • Melamine coating • NPT and Metric reducer options IEC60079-0 IEC60079-1 IEC60079-7 IEC60079-31 Emergency Stop Switches • Pre-configured stations • Applicable in explosive gas atmospheres (AEx de IIC T6 Gb) EN60947-5-1 Pushbuttons Selector Switches Key Selector Switches Pilot Lights Meters (EU2B-YM) Control Station Options: • Class I, Zone 1/Division 2 IECEx IECEx PTB 15.0006U IECEx PTB 15.0007U IECEx PTB 15.0032 APPLICABLE STANDARDS Control Units • Meters KEY FEATURES CERTIFICATE NUMBERS UL/c-UL E347230 • Emergency Stop Switches EN60947-5-5 1 Pilot Lights SPECIFICATIONS Rated Insulation Voltage (Ui) General Specifications Rated Operating Voltage (Ue) IP65 (IEC60529), Type 4X 100 MΩ minimum (500V DC megger) −20 to +50°C (no freezing) 45 to 85% (no condensation) 2,000m Maximum 3 100-m/s² Operating Extremes Emergency Stop Switch: 150-m/s² (without Meter) Damage Limits 1000-m/s² 5 to 55-Hz, amplitude 0.5 mm Emergency Stop Switch: Operating Extremes 5 to 500-Hz, amplitude 0.35-mm, acceleration 50-m/s² (without Meter) 30Hz, amplitude 1.5-mm Emergency Stop Switch: Damage Limits 5 to 500-Hz, amplitude 0.35-mm, acceleration 50-m/s² Insulation Resistance Operating Temperature Operating Humidity Altitude Pollution Degree Shock Resistance Vibration Resistance Insulation Resistance Frequency Impulse Withstand Voltage (Uimp) Insulation Resistance Short-Circuit Protection Conditional Short-Circuit Current Pushbutton Selector Switch Mechanical Life Key Selector Switch Emergency Stop Switch Pushbutton Selector Switch Electrical Life Key Selector Switch Emergency Stop Switch Minimum Operator Stroke Required for Emergency Stop Switch Direct Opening Action Meters Insulation Resistance Rated Operating Voltage (Ue) Resistive Load (AC12) Inductive Load (AC15) Resistive Load (DC12) 120V 10A* 6A 2.2A 1.1A 240V 6A 3A 1.1A 0.55A Inductive Load (DC13) Note: Up to 2 contacts (per control unit): 10A 3 contacts (per control unit): 9A Minimum applicable load: 3V AC/DC, 5mA Applicable operating locations may vary according to operating conditions and load types. A600 10 6.00 240 Volt 30 Operation Impulse Withstand Voltage (Uimp) Input Power Consumption Degree of protection IP65 (IEC60529), Type 4X Housing Material Stainless steel (SUS304) Insulation Resistance Melamine 1-column: Outside coating 2-, 3-, 4-column: Inside and outside coating 600V (with pilot light or ET2A-8PE screw terminal block: 500V) Meter AC input: 300V Meter DC input: 150V 100 MΩ minimum (500V DC megger) Operating Temperature −20 to +50°C (no freezing) Operating Humidity 45 to 85% (no condensation) Altitude 2000m maximum Standard Coating Rated Insulation Voltage 500V 2.8A 1.4A — — 480 Volt 600 Volt 3.00 15 1.5 12 1.2 Agency Approvals UL/c-UL, IECEx/ATEX certified Applicable Enclosure All enclosures expect for 6 Control Units x 4 Column Wall Mount Mounting Style Pilot Light Yes1 Pushbutton Yes Emergency Pushbutton Yes Selector Switch Yes Key Selector Switch Yes Meter Yes Reducer Screw 600 Volt NPT Thread (standard) Metric Thread Make Break Make Break Make Break Make Break Make Break 60 Measurement Control Boxes Maximum Volt-Amperes Maximum current, Amperes 120 Volt Power Consumption Consumption Current Note: Use a commercially available CT (current transformer) for all AC ammeters, and install the CT in a non-hazardous location. 7200 720 Degree of Protection IP65, TYPE4X (UL) Grounding Terminal Screw Material Stainless Steel Applicable Wire Contact Rating Code Designation Thermal Continuous Test Current Amperes Moving core 4kV 1VA 5A, 10A, 30A, 50A, etc 1A, 5A 3 times, etc 150V Moving coil 2.5kV 0 to10V DC, 4 to 20mA, etc. 0.15W 1mA Impulse Withstand Voltage (Uimp) Rated Insulation Voltage (Ui) Control Unit Rated Thermal Current (Ith) DC Operation Extended Memory Contact Rating (Switches) Rated Operating Current (Ie) 300V Input (CT Ratio) Maximum Operator Emergency Stop Switch 9.0mm Stroke Note: Contacts will bounce during operation of pushbuttons and selector switches (reference value: 20ms). Be sure to take contact bounce time into consideration when designing a control circuit. AC 50/60Hz Rated Insulation Voltage (Ui) 7.0mm 600V 10A* 24V 10A* 10A* 8A 4A 2.5 100 MΩ minimum (500V DC megger) Accuracy Class 600V 50mΩ maximum (initial value) 6kV 100MΩ minimum (500V DC megger) 250V/10A fuse (Type aM IEC60269-1/IEC60269-2) 1,000A 1,000,000 operations minimum 500,000 operations minimum 500,000 operations minimum 50,000 operations minimum 250,000 (switching frequency 1800 operations/hr) 250,000 (switching frequency 900 operations/hr) 250,000 (switching frequency 900 operations/hr) 50,000 (switching frequency 900 operations/hr) Rated Insulation Voltage (Ui) Transformer 500V 6V, 12V, 24V AC/DC 120V, 230V, 240V, 380V, 480V AC 4kV 100 MΩ minimum (500V DC) 50/60Hz 0.3W 1.5VA Approx. 40,000 hours Life (reference value) Note: Because the built-in LED lamp is a high-brightness version, the lamp may light dimly due to induction even when power is off. DC ammeter Contact Resistance Full Voltage Power Consumption (approx.) Switches Rated Insulation Voltage Transformer Impulse Withstand Voltage (Uimp) AC ammeter Degree of Protection Voltage Stranded Wire (mm2) 1.5 to 2.5 Solid Wire (mm2) 1.2 to 1.6 Solid/Stranded Wire (AWG) 16-14 1: c-UL explosion protection is different when pilot light is installed. 2 SWITCHES (CONTROL UNITS) Pushbuttons Emergency Stop Switches Pilot Lights Selector Switches Pushbuttons Key Selector Switches Meters EU2B - YM 5 3 A 10 F R EU2B - YB1 11 F S D Operator (style / function) Button color Contact arrangement B1 : Flush pushbutton / Momentary Blank: Red, Green, Black, 10 : 1NO 01 : 1NC B2 : Extended pushbutton / Momentary and White included 20 : 2NO 02 : 2NC Y : Yellow S : Blue B3 : Mushroom pushbutton / Momentary 30 : 3NO 03 : 3NC Terminals 11 : 1NO-1NC 12 : 1NO-2NC F : Finger-safe terminal (IP20) C : Exposed screw terminal 21 : 2NO-1NC Part Number EU2B-YB110➃➀–D EU2B-YB101➃➀–D EU2B-YB111➃➀–D EU2B-YB120➃➀–D EU2B-YB102➃➀–D EU2B-YB121➃➀–D EU2B-YB112➃➀–D EU2B-YB130➃➀–D EU2B-YB103➃➀–D EU2B-YB210➃➀–D EU2B-YB201➃➀–D EU2B-YB211➃➀–D EU2B-YB220➃➀–D EU2B-YB202➃➀–D EU2B-YB221➃➀–D EU2B-YB212➃➀–D EU2B-YB230➃➀–D EU2B-YB203➃➀–D EU2B-YB310➃➀–D EU2B-YB301➃➀–D EU2B-YB311➃➀–D EU2B-YB320➃➀–D EU2B-YB302➃➀–D EU2B-YB321➃➀–D EU2B-YB312➃➀–D EU2B-YB330➃➀–D EU2B-YB303➃➀–D Style and Function Flush Momentary Extended Momentary Mushroom Momentary Contact Arrangement 1NO 1NC 1NO-1NC 2NO 2NC 2NO-1NC 1NO-2NC 3NO 3NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-1NC 1NO-2NC 3NO 3NC 1NO 1NC 1NO-1NC 2NO 2NC 2NO-1NC 1NO-2NC 3NO 3NC Weight (Approx.) Function Set pointer M : Meter blank : non -R : with set pointer Input current 1 : 1A 5 : 5A Terminals Specification of overload scale F : Finger-safe terminal (IP20) 3: 3 times 2 : 2 times 5 : 5 times N:Non C : Exposed screw terminal Type of meter A : AC ammeter Measuring range Direct measuring  1 : 1A    5 : 5A For current transformers: 10 : 10A  15 : 15A  20 : 20A   30:30A   50:50A   60 : 60A  75 : 75A 100:100A 150:150A   ➀ Button Color 68g 92g ➀ Blank - supplied with red, green, black, and white buttons 116g For yellow or blue buttons, specify Y (yellow) or S (blue). EU2B - YM 010 VD F-PER-R Input 70g 94g 118g 76g 101g Specify a button color code in place of ➀ in the part number B : black G : green R : red S : blue W : white Y : yellow AC input meter (ammeter) 125g Emergency Stop Switches EU2B - YBV3 11 F R Operator (style / function) BV3 : 40mm mushroom/push, pull or twist release Contact arrangement 01 : 1NC 11 : 1NO-1NC 02 : 2NC 03 : 3NC 12 : 1NO-2NC Operator Contact Arrangement EU2B-YBV301➃R 1NC EU2B-YBV311➃R 1NO-1NC EU2B-YBV302➃R ø40 Mushroom 2NC EU2B-YBV312➃R 1NO-2NC EU2B-YBV303➃R 3NC DC input meter Button color R : Red Terminals F : Finger-safe terminal (IP20) C : Exposed screw terminal Weight (Approx.) Description Part Number EU2B-YM53A5➃ Capacity: 5A Expansion scale: x3 EU2B-YM53A10➃ Capacity:10/5A Expansion scale: x3 EU2B-YM13A10➃ Capacity:10/1A Expansion scale: x3 EU2B-YM53A15➃ Capacity:15/5A Expansion scale: x3 EU2B-YM13A15➃ Capacity:15/1A Expansion scale: x3 EU2B-YM13A20➃ Capacity:20/1A Expansion scale: x3 EU2B-YM53A30➃ Capacity:30/5A Expansion scale: x3 EU2B-YM13A30➃ Capacity:30/1A Expansion scale: x3 EU2B-YM53A50➃ Capacity:50/5A Expansion scale: x3 EU2B-YM53A60➃ Capacity:60/5A Expansion scale: x3 EU2B-YM53A75➃ Capacity:75/5A Expansion scale: x3 EU2B-YM53A100➃ Capacity:100/5A Expansion scale: x3 EU2B-YM53A150➃ Capacity:150/5A Expansion scale: x3 EU2B-YM010VD➃-PER 0-10V DC Input Scale: 0 to 100% EU2B-YM010VD➃-60HZ 0-10V DC Input Scale: 0 to 60Hz EU2B-YM001MD➃-PER 0-1mA DC Input Scale: 0 to 100% EU2B-YM001MD➃-60HZ 0-1mA DC Input Scale: 0 to 60Hz EU2B-YM001MD➃-80HZ 0-1mA DC Input Scale: 0 to 80Hz EU2B-YM420MD➃-PER 4-20mA DC Input Scale: 0 to 100% EU2B-YM420MD➃-60HZ 4-20mA DC Input Scale: 0 to 60Hz Weight (approx.) 270g Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal) Button Color 96g 120g Set pointer blank : non -R : with set pointer Specification of scale -PER : 0~100% -60HZ : 0~60Hz -80HZ : 0~80Hz Function M : Meter Input voltage or current Type of meter 010 : 0-10V 001 : 0-1mA VD : DC voltmeter 420 : 4-20mA etc. MD : DC ammeter Terminals F : Finger-safe terminal (IP20) C : Exposed screw terminal Note: ➀ Button Color. Specify a contact terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal) Part Number Meters R : Red 144g Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal) 3 Pilot Lights Part Number Operating Voltage Type EU2B-YL1126➃D➀ 120V AC EU2B-YL1236➃D➀ 230V AC Transformer EU2B-YL1246➃D➀ 380V AC EU2B-YL1486➃D➀ 480V AC EU2B-YL166➃D➀ 6V AC/DC Full Voltage ➀ Illumination Color Code EU2B - YL1 22 F D R R : red G : green A : amber Y : yellow PW : white S : blue 150g 240V AC EU2B-YL1386➃D➀ EU2B-YL111➃D➀ Weight (Approx.) 12V AC/DC Lens/LED Colors R : Red G : Green A : Amber Y : Yellow PW : White S : Blue Operator (style / function) L1 : Pilot Light / dome Operating voltage 126 : AC 120V (Transformer type) 246 : AC 240V (Transformer type) 386 : AC 380V (Transformer type) 486 : AC 480V (Transformer type) 108g 66 : AC/DC 6V (Full voltage type) 11 : AC/DC 12V (Full voltage type) 22 : AC/DC 24V (Full voltage type) Terminals F : Finger-safe terminal (IP20) C : Exposed screw terminal 24V AC/DC EU2B-YL122➃D➀ Note: ➀ Illumination Color. Specify a contact terminal style in place of ➃ in the part number: F (Fingersafe terminal), C (Exposed screw terminal) 2 Position Selector Switches EU2B - YS 2 11 N1 F A Operator (style / function) S : Selector (Knob operator) SK: Key selector (Key operator) Number of Positions / Spring Return Action 2 : 2-position / Maintained 3 : 3-position / Maintained 2R : 2-position / Maintained (Overlap) 31 : 3-position / Spring return from right 2J : 2-position / Maintained (Special function) 32 : 3-position / Spring return from left 21 : 2-position / Spring return from right 33 : 3-position / Spring return two-way Selector Switches Operator Position Contact Mounting NO L 1 R ● NC NO 3 1 NO NC 3 1 NC NO 3 1 ● NC NO NO NO NC NC NC NO NO NC NO NC NC NO 3 1 2 3 1 2 3 1 2 3 1 2 3 1 ● NC 2 ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Maintained L R R Maintained L R Spring Return from Right L Operator Position R L Mounting L NO 1 ● EU2BYS2110 ➃ EU2BYSK210➃➂ EU2BYSK2110➃➂ EU2BYS201➃ EU2BYS2101➃ EU2BYSK201➃➂ EU2BYSK2101➃➂ EU2BYS220 ➃ EU2BYS2120 ➃ EU2BYSK220➃➂ EU2BYSK2120➃➂ NC NO 3 1 EU2BYS202➃ EU2BYS2102➃ EU2BYSK202➃➂ EU2BYSK2102➃➂ NO NC 3 1 EU2BYS211➃ EU2BYS2111➃ EU2BYSK211➃➂ EU2BYSK2111➃➂ NC NO 3 1 EU2BYS230 ➃ EU2BYS2130 ➃ EU2BYSK230➃➂ EU2BYSK2130➃➂ EU2BYS203 ➃ EU2BYS2103 ➃ EU2BYSK203➃➂ EU2BYSK2103➃➂ EU2BYS221➃ EU2BYS2121➃ EU2BYSK221➃➂ EU2BYSK2121➃➂ EU2BYS212➃ EU2BYS2112➃ EU2BYSK212➃➂ EU2BYSK2112➃➂ NC NO NO NO NC NC NC NO NO NC NO NC NC 3 1 2 3 1 2 3 1 2 3 1 2 3 EU2BYS2R11➃ R Contact EU2BYS210 ➃ N/A EU2BYSK2R11➃➂ N/A Key is removable in all maintained positions. Specify key removal position in place of ➂ in the part number. See table. Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal). 2-position Terminals F : Finger-safe terminal (IP20) C : Exposed screw terminal Circuit Number Blank : No Designation N* : See charts Key Selector Switches Spring Return from Right L Key Removable Position See option codes below Contact arrangement 10 : 1NO 03 : 3NC 11 : 1NO-1NC 02 : 2NC 01 : 1NC 21 : 2NO-1NC 30 : 3NO 12 : 1NO20 : 2NO 2NC R ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● Selector Switches Key Selector Switches Maintained Maintained L R L EU2BYS2J10 ➃ EU2BYSK2J10➃➂ EU2BYS2J01➃ EU2BYSK2J01➃➂ EU2BYS2J20 ➃ EU2BYSK2J20➃➂ EU2BYS2J02➃ EU2BYSK2J02➃➂ EU2BYS2J11➃ EU2BYSK2J11➃➂ EU2BYS2J30 ➃ EU2BYSK2J30➃➂ EU2BYS2J03 ➃ EU2BYSK2J03➃➂ EU2BYS2J21➃ EU2BYSK2J21➃➂ EU2BYS2J12➃ EU2BYSK2J12➃➂ ➂ Key Removable Option Codes (2-position) 2-position/inverse cam Contact Block 1 Contact Block 2 Contact Block 3 4 R 3 Position Selector Switches Selector Switches Operator Position Contact Mounting L NO 1 ● NO 3 NO 2 NO 3 NC 1 NC 3 NC 2 NC 3 NO 1 NC 3 NC 1 C R Maintained L C R Spring Return from Right L C R Key Selector Switches Spring Return from Left L C Spring Return Two Way R L C R Maintained L C R Spring Return from Right L C R Spring Return from Left L C R Spring Return Two Way L C R EU2BYS320➃ EU2B-YS3120➃ EU2B-YS3220➃ EU2B-YS3320➃ EU2B-YSK320➃➂ EU2B-YSK3120➃➂ EU2B-YSK3220➃➂ EU2BYSK3320➃➂ EU2BYS320N1➃ EU2B-YS3120N1➃ EU2BYS3220N1➃ EU2BYS3320N1➃ EU2BYSK320N1➃➂ EU2BYSK3120N1➃➂ EU2BYSK3220N1➃➂ EU2BYSK3320N1➃➂ EU2BYS302➃ EU2B-YS302➃ EU2B-YS3202➃ EU2B-YS3302➃ EU2B-YSK302➃➂ EU2B-YSK302➃➂ EU2B-YSK3202➃➂ EU2BYSK3302➃➂ EU2BYS302N1➃ EU2BYS3102N1➃➂ EU2BYS3202N1➃➂ EU2BYS3302N1➃ EU2BYSK302N1➃➂ EU2BYSK3102N1➃➂ EU2BYSK3202N1➃➂ EU2BYSK3302N1➃➂ EU2BYS311➃ EU2B-YS311➃ EU2B-YS3211➃ EU2B-YS3311➃ EU2B-YSK311➃➂ EU2B-YSK311➃➂ EU2B-YSK3211➃➂ EU2BYSK3311➃➂ EU2BYS311N1➃ EU2B-YS3111N1➃ EU2BYS3211N1➃ EU2BYS3311N1➃ EU2BYSK311N1➃➂ EU2BYSK3111N1➃➂ EU2BYSK3211N1➃➂ EU2BYSK3311N1➃➂ ● ● ● ● ● ● NO 3 NO 1 NC 2 ● EU2BYS311N2➃ EU2B-YS3111N2➃ EU2BYS3211N2➃ EU2BYS3311N2➃ EU2BYSK311N2➃➂ EU2BYSK3111N2➃➂ EU2BYSK3211N2➃➂ EU2BYSK3311N2➃➂ NC 2 ● EU2B-YS3111N3➀ NO 3 EU2BYS311N3➃ EU2BYS3211N3➀ EU2BYS3311N3➀ EU2BYSK311N3➃➂ EU2BYSK3111N3➃➂ EU2BYSK3211N3➃➂ EU2BYSK3311N3➃➂ NO 2 ● EU2BYS311N4➃ EU2B-YS3111N4➃ EU2BYS3211N4➃ EU2BYS3311N4➃ EU2BYSK311N4➃➂ EU2BYSK3111N4➃➂ EU2BYSK3211N4➃➂ EU2BYSK3311N4➃➂ ● EU2BYS330➃ EU2B-YS3130➃ EU2B-YS3230➃ EU2B-YS3330➃ EU2B-YSK330➃➂ EU2B-YSK3130➃➂ EU2B-YSK3230➃➂ EU2BYSK3330➃➂ ● EU2BYS303➃ EU2B-YS3103➃ EU2B-YS3203➃ EU2B-YS3303➃ EU2B-YSK303➃➂ EU2B-YSK3103➃➂ EU2B-YSK3203➃➂ EU2BYSK3303➃➂ ● EU2B-YS3 21N1➃ EU2B-YS3121N1➃ EU2BYS3221N1➃ EU2BYS3321N1➃ EU2BYSK321N1➃➂ EU2BYSK3121N1➃➂ EU2BYSK3221N1➃➂ EU2BYSK3321N1➃➂ EU2B-YS3 12N1➃ EU2B-YS3112N1➃ EU2BYS3212N1➃ EU2BYS3312N1➃ EU2BYSK312N1➃➂ EU2BYSK3112N1➃➂ EU2BYSK3212N1➃➂ EU2BYSK3312N1➃➂ ● ● ● ● NC 3 NO 1 ● NO 2 ● NO 3 NC 1 NC 2 NC 3 NO 1 NC 2 NO 3 NC 1 NO 2 NC 3 ● ● ● ● ● Specify a terminal style in place of ➃ in the part number: F (Finger-safe terminal), C (Exposed screw terminal). L Operator Position C Key is removable in all maintained positions. Specify key removal position in place of ➂ in the part number. See table. ➂ Key Removable Option Codes (3-Position) R Code A B C D E G H Contact Block Position  Contact Block 1  Contact Block 2  Contact Block 3 The key can be released in any maintained position. 5 Description Key removable in any position Key removable in left and center positions Key removable in center and right positions Key removable in center position Key removable in left and right positions Key removable in left position Key removable in right position) CONTROL BOXES 1 control unit 2 control units 5 control units 4 control units EC2BB51B051➀➁-U EC2BB32B042➀➁-U 4 control units EC2BB31B031➀➁-U EC2BB51B041➀➁-U 6 control units 8 control units EC2BB32B062➀➁-U EC2BB52B082➀➁-U 10 control units EC2B-B52B102➀➁-U 2 columns 1 column EC2BEC2BB21B011➀➁-U B21B021➀➁-U 3 control units 6 control units 9 control units 15 control units EC2BEC2BB33B093➀➁-U B53B123➀➁-U EC2BB53B153➀➁-U 18 control units EC2BB63B183➀➁-U 3 columns EC2BB33B063➀➁-U 12 control units ➀ Thread Size Code Description ➁ Terminal Block Style Code Description M1 M2 M3 M4 M5 N1 N2 N3 N4 blank C F M16 M20 M25 M32 M40 NPT1/2 NPT3/4 NPT1 NPT1 1/4 no terminal block Exposed screw terminals Finger-safe terminals Specify thread size in place of ➀ in part number. Specify terminal block style in place of ➁ in part number (standard versions do not contain a terminal block). STANDARD CONTROL STATIONS 1 Control Unit × 1 Column 1 pushbutton 31 j ➀ 42 1 pilot light X1 X2 j EC2B-1102BN2N 1-U EC2B-1102BN2N  2-U Flush momentary 1NO contact Nameplate ON Button color: black, green, red, and white 1NO-1NC contact Flush momentary 1NC contact Nameplate OFF Button color: black, green, red, and white Flush momentary 1NO-1NC contact Nameplate OFF Button color: black, green, red, and white EC2B-1101BN2  3-U EC2B-1101BN2 13-U EC2B-1101BN2 14-U EC2B-1101BN2  6-U ➀ 120V AC Illumination color: red 240V AC Illumination color: red 24V AC/DC Illumination color: red 120V AC Illumination color: green 240V AC Illumination color: green 24V AC/DC Illumination color: green 3 j 2 Flush momentary 1NO-1NC contact Nameplate ON Button color: black, green, red, and white EC2B-1101BN2 12-U EC2B-1106BN2N 1-U 1 EC2B-1102BN2N  4-U EC2B-1101BN2 11-U 1 selector switch OFF ON EC2B-1102BN2N  3-U 4 Knob selector 2-position main➀ tained 1NO-1NC contact Name plate OFF-ON 1 key selector switch 1 OFF ON 3 OFF ON j 2 1 emergency stop switch EC2B-1106BN2N  4-U 4 Key selector 2-position maintained (removable at all ➀ positions) 1NO-1NC contact Nameplate OFF-ON OFF ON EC2B-1102BN2N 7-U 1 1 Emergency stop switch 2NC contact j ➀ Nameplate EMERGENCY STOP Button color (red) 2 2 2 Control Units × 1 Column 2 flush pushbuttons 2 Mushroom Pushbuttons EC2B-2102BN2N 1-U 3 4 1 Button color (black, green, red, and white buttons) k 2 Flush momentary ➁ 1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) 1 pilot light/1 pushbutton X1 3 Flush momentary j ➀ 1NO contact, Nameplate ON X2 3 1 4 2 j 1 4 3 2 1 4 2 j k EC2B-2102BN2N  4-U Mushroom momentary ➀ 1NO-1NC contact, Nameplate ON Button color (black) Mushroom momentary  1NO-1NC contact, Nameplate OFF Button color (red) EC2B-2110BN2N  5-U EC2B-2110BN2N  6-U EC2B-2110BN2N  3-U ➀ 120V AC Illumination color: red 240V AC Illumination color: red 24V AC/DC Illumination color: red ➁ Flush momentary 1NO-1NC contact Name plate STOP Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact Name plate STOP Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact Name plate STOP Button color (black, green, red, and white buttons) k Specify terminal style code in place of  in part no. C (standard screw terminal), F (finger-safe screw terminal) 6 2 Control Units × 1 Column 1 pilot light / 1 selector switch X1 EC2B-2117BN2N  3-U EC2B-2117BN2N  4-U X2 j 120V AC ➀ Illumination color: red 3 1 OFF ON k 2 4 240V AC Illumination color: red OFF ON Knob, 2-position, ➁ 1NO-1NC contact Maintained, Name plate OFF-ON Knob, 2-position, 1NO-1NC contact Maintained, Name plate OFF-ON OFF ON 3 Control Units × 1 Column 1 pilot light / 2 pushbuttons X1 EC2B-3110BN2N  6-U EC2B-3110BN2N  3-U 120V AC ➀ Illumination color: red EC2B-3110BN2N  5-U 240V AC Illumination color: red 24V AC/DC Illumination color: red k Flush momentary ➁ 1NO contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO contact, Nameplate ON Button color (black, green, red, and white buttons) l Flush momentary ➂ 1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) X2 j 4 3 2 1 3 pushbuttons 1 meter / 2 pushbuttons EC2B-3102BN2N 1-U 3 1 4 3 2 1 4 3 2 1 4 2 A j ➀ k Flush momentary 1NO-1NC contact, ➁ Blank nameplate Button color (black, green, red, and white buttons) l ➂ 3 EC2B-3152BN2N 1-U ➀ Specify input, capacity, and scale k ➁ Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) l ➂ Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) j 1 4 3 2 1 4 2 Specify the meter's capacity and scale in place of  in the part number 4 Control Units × 1 Column 2 pilot lights / 2 pushbuttons X1 X1 EC2B-4110BN3N  5-U EC2B-4110BN3N  6-U EC2B-4110BN3N  3-U 240V AC, Illumination color: red 24V AC/DC, Illumination color: red X2 j ➀ 120V AC, Illumination color: red X2 ➁ 120V AC, Illumination color: green 240V AC, Illumination color: green 24V AC/DC, Illumination color: green Flush momentary ➂ 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary ➃ 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) 3 1 4 3 2 1 4 2 k l m 1 pilot light / 2 pushbuttons / 1 selector switch EC2B-4113BN3N  5-U EC2B-4113BN3N  6-U EC2B-4113BN3N  3-U X2 j ➀ 120V AC, Illumination color: red 240V AC, Illumination color: red 24V AC/DC, Illumination color: red 3 1 4 3 2 1 Flush momentary ➁ 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) 4 2 Flush momentary ➂ 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) 1 3 Knob, 2-position, maintained ➃ 1NO-1NC contact Nameplate HAND-AUTO Knob, 2-position, maintained 1NO-1NC contact Nameplate HAND-AUTO Knob, 2-position, maintained 1NO-1NC contact Nameplate HAND-AUTO X1 k l m HAND AUTO HAND AUTO HAND AUTO HAND AUTO 5 Control Units × 1 Column 2 pilot lights / 2 pushbuttons / 1 selector switch X1 X1 3 OFF ON X2 j X2 k 1 4 3 2 1 4 2 2 4 l m n 1 3 EC2B-5113BN3N  5-U EC2B-5113BN3N  6-U EC2B-5113BN3N  3-U ➀ 120V AC, Illumination color: red ➁ 120V AC, Illumination color: green 240V AC, Illumination color: red 24V AC/DC, Illumination color: red 240V AC, Illumination color: green 24V AC/DC, Illumination color: green Flush momentary ➂ 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate ON Button color (black, green, red, and white buttons) Flush momentary ➃ 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color (black, green, red, and white buttons) Flush momentary 1NO-1NC contact, Nameplate OFF Button color black, green, red, and white buttons) Knob, 2-position, Maintained, ➄ 1NO-1NC contact, Name plate HAND-AUTO Knob, 2-position, Maintained, 1NO-1NC contact Name plate HAND-AUTO Knob, 2-position, Maintained, 1NO-1NC contact Name plate HAND-AUTO HAND AUTO Specify terminal style code in place of  in part no. C (standard screw terminal), F (finger-safe screw terminal) 7 HAND AUTO HAND AUTO DIMENSIONS All dimensions in mm Pilot Lights Control Units Shown with finger-safe contacts Pushbuttons 61.4 67.7 24.5 1.0 to 4.5 (panel thickness) 67.7 62.0 ø 40.0 ø40 39.0 ø40 Extended ø 24.0 Mushroom Flush 19.3 20.3 Emergency Stop Switches 67.7 Meters Shown with finger-safe contacts 32.2 35.0 1.0 to 4.5 (Panel thickness) 1.0 to 4.5 (panel thickness) 67.7 ø 64.0 47.4 8.0 38.4 ø 40.0 Shown with finger-safe contacts ø 28.0 13.3 1.0 to 4.5 (panel thickness) 67.7 20.3 32.2 13.3 32.0 32.5 48.0 ø 40.0 33.0 ø 40.0 Shown with finger-safe contacts Selector Switches Shown with finger-safe contacts 50 min (*note) +0.2 4.8 0 +0.5 1.0 to 4.5 (panel thickness) 67.7 Panel thickness: 1.0 to 4.5 mm. *Note: The meter can be mounted on the top mounting holes of a standard 50mm mounting centers. The meter can be mounted on any mounting hole with a 70mm or larger mounting center. Key Selector Switch 32.2 38.4 ø 40.0 Shown with finger-safe contacts 47.4 70 min 33 0 37.3 .5 +0 0 0.5 ø3 32.2 47.4 62.1 Mounting Hole Dimensions 38.4 ø 40.0 33.5 27.3 1.0 to 4.5 (panel thickness) 67.7 8 1, 2 control units x 1 column 2, 3, 4, 5 control units x 2 columns weight: 1.2kg/1.4kg weight: 3.8/4.2/4.6/5.0 kg 4-ø7 (mounting hole) 110 95 10 6 1.5 Mounting tab 4 control units 70 70 230 220 210 3 control units 70 5 control units A (mounting hole) Hinge 70 2×50P 100 142 (mountin g hole ) 170 4-ø10 Reducer M4 grounding terminal M5 lid mounting screw Hinge 2 Mounting tab 4×50P 36.5 36 50 2 control units 106 3×50P 50 (mounting hole) 2 control units R 1 control unit (mounting hole) 115 Reducer M4 grounding terminal M5 lid mounting screw 70 3 control units x 1 column Dimensions 2, 3, 4, 5 control units x 3 columns weight: 1.8kg No. of Control Units A R 2 or 3 250 180 4 or 5 350 280 weight: 4.8/5.2/6.5/7.1 kg 3 control units 4-ø7 (mounting hole) 106 (mounting hole) 1.5 Mounting tab 320 310 300 3×50P 110 95 140 140 50 2×50P 4 control units 2 control units 115 106 2 Mounting tab R Hinge 4×50P Reducer M4 grounding terminal M5 lid mounting screw Hinge A 5 control units 140 (mounting hole) 2×50P 140 36.5 192 150 220 (mounting hole) 4-ø10 (mounting hole) 3 control units 70 36 70 Reducer M4 grounding terminal M5 lid mounting screw Dimensions 4, 5 control units x 1 column 2 or 3 250 180 4 or 5 350 280 weight: 8.1kg 115 110 95 5 control units 320 310 300 4-ø7 (mounting hole) 106 1.5 (mounting hole) Mounting tab Control Unit Mounting Holes 140 106 2 Mounting tab 4-ø10 70 9 70 330 (mounting hole) Hinge 36.5 Reducer M4 grounding terminal M5 lid mounting screw Hinge 400 5×50P 322 250 (mounting hole) 350 (mounting hole) 36 4x40P 3x50P A 6 control units x 3 columns weight: 2.4kg 4 control units No. of Control Units Reducer M4 grounding terminal M5 lid mounting screw R Terminal Blocks Fittings and Reducers Terminal blocks are not supplied with the standard control boxes (without wiring). When wiring inside the control box is required, specify the wiring circuit. The terminal block type used on the control boxes with wiring depends on the terminal style of the control unit. Reducers installed at the bottom of the control box are as follows: 1 column: 1 reducer, 2 columns: 2 reducers, 3 columns: 3 reducers, 4 columns: 4 reducers. Material is nickel-plated brass. Use cable lead-in fittings that are commercially available. See the following table for optional reducers. Control Box Style Part No. Thread Size Symbol UL c-UL C terminal style exposed screw terminal ET2A-8PE polyamide IECEx TUR 15.0043U, TÜV 15 ATEX 7799U 34 22 1 column (1 to 3 control units) 2, 3 columns (2, 3 control units) 101 123 F terminal style 1, 2, 3 columns (4, 5 control units) 3, 4 columns (6 control units) 32 22 finger-safe screw terminal IP20 clamp terminal: 264-238 (WAGO) polyamide ECEx PTB 04.0003U, PTB 98 ATEX 3129U 84 96 1-column 1, 2 units 1-column 3 units 1-column 4, 5 units (1 2-column 2, 3 units (2 (1 terminal block/8 poles) (1 terminal block/ 8 poles) terminal block/ 8 poles) terminal blocks/16 poles) 3-column 2, 3 units (3 terminal blocks/ 24 poles) 3-column 4, 5, 6 units (6 terminal blocks/ 8 poles) M16 M20 M25 M32 NPT 1/2 NPT 3/4 NPT 1 M25 M32 M40 NPT 3/4 NPT 1 NPT 1 1/4 M1 M2 M3 M4 N1 N2 N3 M3 M4 M5 N2 N3 N4 ™ ™ ™ ™ ™ ˜ ™ ™ ™ ™ ™ ˜ ™ ˜: Standard reducer ™: non-standard reducer The number of terminal blocks, poles, and the installation direction that can be installed on the control box are as follows: 2-column 4,5 units (4 terminal blocks/ 32 poles) EC9E-H3M16E-UL EC9E-H3M20-UL EC9E-H3M25-UL EC9E-H3M32-UL EC9E-H3NPT1-UL EC9E-H3NPT2-UL EC9E-H3NPT3-UL EC9E-H4M25-UL EC9E-H4M32-UL EC9E-H4M40-UL EC9E-H4NPT2-UL EC9E-H4NPT3-UL EC9E-H4NPT4-UL The reducers in the table above are for replacement use only. All EC2B boxes are supplied with a reducer that has been secured to the housing per UL regulations. If it is necessary to replace a reducer, the user should follow appropriate UL standards for securing to EC2B housing. 4-column 6 units (8 terminal blocks/ 64 6 units poles)(84-column terminal blocks/ 64 poles) ACCESSORIES All dimensions in mm Nameplates Used for pilot light, pushbutton, selector switch, and key selector switch. EU9Z-NM Nameplate Inserts Dimensions 40 (35) Appearance Marking Plate 4.5 28.5 Part Number (6.5) Appearance 0 ø4 1.5 Legend Part Number Blank ON EU9Z-NP0 EU9Z-NP1 OFF EU9Z-NP2 START EU9Z-NP3 STOP EU9Z-NP4 OFF-ON EU9Z-NP31 HAND-AUTO EU9Z-NP35 HAND-OFF-AUTO EU9Z-NP53 Material: Aluminum Installing the Insert to the Nameplate Removing the Insert from the Nameplate Insert ➁ Flat screwdriver Insert ➀ 10 Nameplate To remove the Insert, insert a flat screwdriver between the Insert and Nameplate. Emergency Stop Switch Padlock Cover Rubber Boots Used with EU2B-YBV emergency stop switch to maintain the switch in the latched status. Appearance Description/Usage Appearance Part Number Part Number Dimensions For Flush Pushbuttons Base EU9Z-DB1 46 Not for use with name plate EU9Z-PCE For Flush Pushbuttons For use with name plate EU9Z-DB1N 8 32.2 50 55.4 For Extended Pushbuttons Coating: yellow Material: Stainless Steel Not for use with name plate EU9Z-DB2 Mounting Hole Plug Used to plug unused mounting holes (ø30.5) on the mounting panel. Appearance Part Number Dimensions / Usage For Extended Pushbuttons 23.2 EU9Z-DB2N ø40 For use with name plate EU9Z-BP 13.3 Emergency Stop Switch Nameplate Stickers Appearance Legend Buttons Part Number Appearance Dimensions 8 ø5 ø5 Blank 8 Style Part Number Flush HW1A-B1➀ Button Color Code EU9Z-NVS0 ø4 ø4 0.5 0.5 8 8 ø5 ø5 Emergency Stop EU9Z-NVS27 ø4 Extended HW1A-B2➀ ø40 Mushroom HW1A-B4➀ ø4 0.5 0.5 Specify a color code in place of ➀ in the Ordering Number. R : red G : green B : black Y : yellow W : white S : blue Material: yellow vinyl Legend: black Padlock Cover Material: Polyacetal EU2B-YB2 extended pushbutton: to maintain latched status EU2B-YB1 flush pushbutton/EU2B-YSK key selector switch: to prevent operation Appearance Part Number 1.0 to 10.5 (panel thickness) Lenses Appearance Dimensions 46 32.1 EU9Z-PC Material: AS resin (gasket supplied) 44 8 24.5 Note: mounted to outside of enclosure with screws, not provided by IDEC Material: Stainless Steel 11 Lens Color Part Number Red Green Amber Yellow White Blue EU9Z-LR EU9Z-LG EU9Z-LA EU9Z-LY EU9Z-LW EU9Z-LS Control Box Shade LED Lamps Shape Part No. D Operating Voltage 6V AC/ DC±10% Current Draw AC DC 8mA 7mA (A, R, W) 5.5mA (G, PW, S) Part Number LSTD-6➀ 12V AC/ DC±10% 11mA 10mA LSTD-1➀ 24V AC/ DC±10% 11mA 10mA LSTD-2➀ Illumination Color Code Specify a color code in place of ➀ in the part number R : red G : green A : amber PW : white S : blue Use a white (PW) LED with yellow (Y) lens. Base W EC9Z-F2A21M EC9Z-F2A31M H EC9Z-F2A51 EC9Z-F2A32 BA9S/13 Material: stainless steel Thickness: 1mm Photo: Part No. EC9Z-F2A52 EC9Z-F2A52 EC9Z-F2A33 EC9Z-F2A53 EC9Z-F2A63 EC9Z-F2A64 Applicable Control Box EC2B-11*B EC2B-21*B EC2B-31*B EC2B-41*B EC2B-51*B EC2B-22*B EC2B-32*B EC2B-42*B EC2B-52*B EC2B-23*B EC2B-33*B EC2B-43*B EC2B-53*B EC2B-63*B EC2B-64*B Dimensions (mm) H W D 180 160 160 230 160 160 360 160 160 260 420 160 360 420 160 260 510 160 360 510 160 410 410 510 580 160 160 Protects control units from direct sunlight and rain. The surface of the control box shade is uncoated. Can be installed by tightening to the mounting tabs on the control box. Control box shade cannot be installed later. Specify shade at time of order. OPERATING INSTRUCTIONS Installation Area Determine the operating current so that the total heat value of 1 wire bundle is below 300 [A2 × wires]. Also, when calculating the heat value, take the current fluctuation (10%) into consideration. [calculation example: EC2B-41**B (8 circuit)] ➀ Apply 10A to 1 circuit, 1A to the remaining 7 circuits: {(10A × 1.1)2 × 2 wires} + {(1A ×1.1)2 × 14 wires} ≈ 259 (can be used because < 300) ➁ Apply 10A to 1 circuit, 2A to the remaining 7 circuits: {(10A × 1.1)2 × 2 wires} + {(2A × 1.1)2× 14 wires} ≈ 310 (cannot be used because > 300) See the table below for the allowable operating current when applying current evenly to each control box. Do not install the EC2B control box in an environment where more than IP65 protection degree (more than Type 4X in North America) is required. Use the EC2B control box under ambient temperature of –20 to +50°C. If the control box is exposed to direct sunlight and the surface temperature may rise above 50°C, provide a shade to keep the surface temperature below 50°C. Installation Use four M6 bolts for 1-column, four M8 bolts for 2- and 3-column, or other methods with equivalent strength to install the control box. Mounting tab thickness is 1.5mm for 1 column and 2mm for 2, 3, and 4 columns. • If bolts become may loose due to vibration, use spring washers. • If bolt corrosion is anticipated, use anti-corrosion bolts or other countermeasures. Allowable Operating Current Notes on Emergency Stop Switches When using the emergency stop switches on safety-related parts of the control system, observe safety standards and regulations of the relevant country or region. Also be sure to perform a risk assessment before operation. Opening/Closing the Lid Use a Philips screwdriver to loosen lid mounting screws. While holding the unhinged side, open the lid slowly without exerting excessive force on the hinge. Before closing the lid, make sure of the following: • No foreign substances are on the packing or joint surfaces. • No displacement of the waterproof packing. • Wires are not caught between the joint surfaces. • Next, close the lid slowly and tighten the screws to a proper torque of 1.6 to 2.4 N·m. Limitation of the Operating Current Major heat sources comes from the wiring which is connected to the control box. Therefore, not only the operating current but wiring conditions (size, no. of wires, no. of wire bundles) may cause temperature rise. When wiring, observe the following conditions. Stranded wire: 1.5 to 2.5 mm2 (UL-c-UL certified) / Solid wire: ø1.2 to ø1.6 mm (16 to 14 AWG) • Maximum no. of wires per bundle: 16 • Maximum operating current: 10A When using the control box under an operating environment of 40°C minimum, use a heat resistant cable of 70°C minimum. Control Box Part No. Max. No. of Circuits EC2B-11 EC2B-21 EC2B-31 EC2B-41 EC2B-51 EC2B-22 EC2B-32 EC2B-42 EC2B-52 EC2B-23 EC2B-33 EC2B-43 EC2B-53 EC2B-63 EC2B-64 3 6 9 12 15 12 18 24 30 18 27 36 45 54 72 Max No. of Wires per Bundle (*1) [wires] ([wires]×[bundle]) Without terminalWith terminal blocks blocks 16 (16×1) 8 (8×1) 16 (16×1) 8 (8×1) 16 (16×1) 8 (8×1) 16 (16×1) 16 (16×1) 16 (16×1) 16 (16×1) 32 (16×2) 16 (8×2) 32 (16×2) 16 (8×2) 32 (16×2) 32 (16×2) 32 (16×2) 32 (16×2) 48 (16×3) 24 (8×3) 48 (16×3) 24 (8×3) 48 (16×3) 48 (16×3) 48 (16×3) 48 (16×3) 48 (16x3) 48 (16x3) 64 (16x4) 64 (16x4) Allowable Operating Current (reference) (*2) 7A 5A 4A 3A 3A 5A 4A 3A 3A 5A 4A 3A 3A 3A 3A *1: Make sure that the number of wires per bundle is a maximum of 16 by reducing the wiring or by jumper wiring. The maximum number of wires per bundle may need to be further reduced depending on the wire size, lead-in fitting, or conduit size. *2: The allowable current value (reference) when applying current evenly to all circuits of the maximum number of circuits. 12 Wiring Removing and Installing the Contact Unit / Lamp Unit Wiring Construction To remove the contact unit or the lamp unit from the operator, pull the protruding yellow part of the locking lever outwards as shown in the figure below using a screwdriver, and turn it to the left. The contact unit or lamp unit can be removed. Observe the laws and regulations in each country concerning wiring construction.Use cable wiring or metal conduit wiring for installation in hazardous locations. If foreign objects or water may enter the box, install a sealing fitting near the cable entry of the box and seal the control box using a compound. Standard type control boxes do not contain a terminal block. Wire the control units directly. EU2B-YB/ YBV EU2B-YS/ YSK 8.0 max. ∗£1.8 max. ∗£1.8 max. mi n. 6.9 max. 6.9 max. 3.6 min ø3 .6 5.5 min. Without insulating sheath With insulating sheath Insulation sheath Wire locking lever indicator (red) 8.0 max. Panel mounting for the operator, lens unit and meter For IP20 clamp terminal (WAGO: 264-238) Remove the locking ring from the operator and check that the rubber gasket is in place. Insert the operator from the panel front into the panel hole. Place the projection on the operator with TOP .2 m Insulation sheath ø4 8.5 max. in. .2 m ø4 Insulation sheath in. (Ring terminal) (Ring terminal) 8.5 max. ➂ (Pull) (Ferrule) ∗ Dimensions after crimping For screw terminal ET2A-8PE locking lever TOP When the contact unit is removed from the emergency stop switch operator, the NO contact closes and the NC contact opens. Do not turn the locking lever when the contact unit is removed from the operator (the red indicator protruding out, see the figure below) or the switch can be damaged. Ring and spade terminals cannot be used for EU2B control units with IP20 finger-safe terminals. Ring and spade terminals cannot be used for IP20 clamp type terminal blocks. When connecting two ferrules to an EU2B control unit, use ferrules without insulating sheath. 5.5 min. (Pull) locking lever Applicable crimping terminal 3.4 max. (Turn) ➂ (Ring terminal) (Lift) ➁ ➁ Stranded wire: 1.25 to 2.5 mm2, solid wire: ø1.2 to ø1.6 mm (AWG16 to 14). Do not connect more than 2 wires to the same terminal. ➀ EU2B-YL (Turn) Applicable Wires (Spade terminal) ➀ (Lift) 5 to 6.6 5 to 6.6 Recommended crimping terminal (WAGO) Ferrule with insulating sheath: 216-204 Ferrule without insulating sheath: 216-104 Crimping plier: 206-204 marking upward and the recess on the mounting panel in the same direction. Meters have no projection. Tighten the locking ring using ring wrench XN9Z-T1 to a torque of 2.5 Nm. When using a nameplate or padlocking cover, install it between the operator and panel. Make sure that the groove of the namplate or padlocking cover and the projection on the TOP marking of the operator are in the same direction. Note: The locking ring for emergency stop switches and meter Insulation Sheath is metallic. The meter can’t mount the nameplate or podlocking cover. Recommended Tightening Torque EU2B control units (M3.5) and ET2A-8PE terminal block (M4): 1.0 to 1.3 N·m Warning Incorrect wiring may cause fire hazard. Observe the following conditions. Be sure to install an insulating sheath on the crimping terminal or the crimping terminal with insulation. Installing the contact unit and lamp unit 5.5 to 6.0 Wire All dimensions in mm. To install the contact unit, place the TOP marking on the operator and the TOP marking on the contact block adapter in the same direction, and then attach the contact unit to the operator. Then turn the locking lever to the right. Follow the same procedure when installing the lamp unit. When installing the lamp unit, check that the inner lens is not loose. The contact block adapters for emergency stop switches cannot be used for pushbuttons, selector, or key selector switches. When connecting solid wires or stranded wires directly, strip the insulation as mentioned below, and insert the wire all the way in. EU2B Control units: 8.6 mm maximum IP20 crimping terminal: 8 to 9 mm When using stranded wires, make sure that there are no wire whiskers. Make sure that the spade crimping terminals and ferrules are inserted all the way in. Use insulated ring terminals for the ET2A-8PE terminal block. Use only applicable crimping terminals and do not directly connect stranded wires or solid wires. TOP marking Projection Nameplate or Padlocking cover Recess on the panel Rubber gasket Locking ring Recess on the Nameplate Nameplate gasket EU2B-YL EU2B-YB EU2B-YS TOP marking TOP marking ➀ ➀ ➁ ➁ TOP inner lens 13 Removing the Contact Block Installing EU9Z-PC Padlock Cover To remove the contact block, insert a flat screwdriver under the latch of the contact block adaptor and disengage the latch as shown in the figure below. (Flush/extended pushbtton/key selector switch) EU9Z-PC can be installed in the following two ways. Remove the cover in the reverse step of installing the cover. Do not install or remove the cover forcefully, or it will cause failure. [Installation A] Cover   Flat Screwdriver Installing the Contact block [Installation B] This method is effective when the neighboring control unit interferes when installing in method A. When installing the contact block after maintenance or wiring, make sure that the contact configuration is correct. Installing the contact block in the incorrect position or incomplete installation may cause malfunction of the switch. Remove the contact block from the operator before installing the contact block to the contact block adaptor. Also make sure that the contact block is correctly installed to the contact block adaptor before attaching the operator. Do not install the contact block adaptor with the operator attached. Otherwise, malfunction may result.   Cover  Protective Grounding Protective grounding must be performed according to the installation environment and rating requirements. Observe laws and regulations set by each country. • Connect the M4 grounding terminal of the EC2B control box to a proper ground (grounding resistance 10Ω maximum). When operating the EC2B control box by connecting to circuits of 300V or below, the grounding resistance must be 100Ω maximum. • When using cables, connect one of the cable cores to the grounding terminal in the enclosure. • If the grounding terminal in the enclosure cannot be used, use the M4 grounding terminal on the outside of the enclosure. Recommended tightening torque: M4: 1.0 to 1.3 Nm M6: 3.9 to 5.4 Nm • For grounding, use appropriate wires (size, material, insulation) that can tolerate the expected maximum grounding current. Be sure to protect the grounding wire with protection, such as metal conduit, from external damage. Accessories Padlock Cover The following padlocks and hasps can be used. (Padlock Size) a Flush/extended pushbutton/key selector switch Emergency Stop Switch b ø3.5 to 7.0 mm ø5.5 to 7.0 mm c 15 mm min. 70 mm max. — — Installing EU9Z-DB Rubber Boots To install the rubber boot on flush and extended pushbuttons, place the rubber boot on the cap and push the rubber boot holder straight. The notches around the rubber boot must show evenly. Rubber boot holder Notches Rubber boot Cap Notches for screwdriver Push-in position Push the rubber boot holder further around on the two notches on the holder so that the holder fits the button completely Make sure that the rubber boot and rubber boot holder are installed straight. On Nameplate Types, the EU2B and the rubber boot holder must be aligned so that when installed, the anti-rotation projection on the EU2B comes to the center of the groove on the holder. Make sure that the rubber boot is installed completely, otherwise water droplets might enter the rubber boot, but no water will enter the control box. Align Recommended Hasp Manufacturer Part No. Panduit PSL-1, PSL-1A, PSL-1.5, PSL-1.5A, PSL-HD1 Master Lock 420, 421 To remove the rubber boot from the flush and extended pushbuttons, gently insert the slotted screwdriver (0.5t x 4w or below) inside a notch on the rubber boot holder and tilt to the direction shown by the arrow ➀. To prevent damage, do not apply excessive force to the EU2B when removing the rubber boot. Padlock and hasp are available in various shapes and sizes. Make sure that they do not interfere with the control units. Note: Not supplied by IDEC. Keep the total weight of padlock and hasp under 1500g max, otherwise the switch may malfunction or result in failure. No vibration should be applied when padlock or hasp are installed. When padlock or hasp are disfigured, stop usage immediately. Ensure that no shock or electric sparks are generated. When using the plate lock padlock cover with the extended pushbutton, the switch contact may turn on/off when the cover is being installed. Ensure to provide functional safety measure to prevent unexpected startup. When using the padlock cover on the safety-related part of the control system, observe safety standards and regulations of the relevant country or region. Also be sure to perform risk assessment before operation. 14 Maintenance and Inspection EC2B Control Boxes EU2B switches should be installed in an appropriate control box. • EC2B control boxes can be installed only in zones 1 and 2. Do not use in zone 0. In North America, the EC2B can be installed in Division 2 areas, but cannot be installed in Division 1 areas. • Turn power off to the EC2B control box before installation, removal, wiring, or maintenance, otherwise explosion, fire hazard, or electric shock may result. • Special skills and knowledge of explosion protection, electric system installation, and relevant laws/regulations are required to transport, install, wire, operate, repair, and inspect the EC2B control box. People without such expertise must not use the EC2B control box, otherwise damage or accident may result. • Do not modify the EC2B, otherwise damage or accident may result. • Do not use a damaged EC2B control box, otherwise damage or accident may result. • W hen connecting external devices, make sure that each cable is connected to the correct terminal, otherwise electric shock, fire hazard, or explosion may result. • Use wires of a proper size to meet voltage and current requirements. Incorrect wiring may cause abnormal temperature rise and lead to fire hazard and explosion. • Connect the grounding terminal to a proper ground, otherwise electric shock, fire hazard, or explosion may result. • Do not sit on or hang from the EC2B control box, otherwise damage, personal injury, or accident may result. • Do not open the lid of the EC2B control box when it is energized, otherwise electric shock, fire hazard, or explosion may result. • Operate the EC2B control box at the rated current and voltage specified in this catalog, otherwise short-circuiting, fire hazard, or explosion may result. • When measuring the insulation resistance of the EC2B control box, make sure that potentially explosive atmosphere of explosive gas or vapor does not exist in the vicinity, otherwise explosion may result. Also, do not touch the terminals without paying attention, otherwise electric shock will result. • Do not place any obstacles in front of the nameplate. • Do not remove the nameplate. • When opening the lid for wiring, maintenance or inspection, make sure that substances such as dust, concrete powder, or metal powder do not enter inside the box, otherwise contact failure or insulation failure may result. • Do not drop the EC2B control box during transportation. • Be sure to open the carton the right way up, otherwise damage or personal injury may result. • Check that the product is what you have ordered. Using an incorrect model might result in malfunction or accident. • Stop operation immediately if abnormal operation occurs. Otherwise, a secondary accident may occur. • The surface temperature of the EC2B control box may become extremely hot during operation. Before maintenance or inspection of the EC2B, be sure to wear gloves to prevent burning your hand. Maintenance and Inspection Method Perform daily or periodical maintenance and inspection for items such as damage and temperature rise of the EU2B switches listed in the Maintenance and Inspection table below. Observe laws and regulations set by each country. Do not open the lid when inspecting the EC2B while it is energized. Never disassemble the control box. Do not use tools that cause sparks during maintenance and inspection. When using measuring devices, use explosion-protected types. When the EC2B needs to be disassembled or assembled for maintenance or repair, contact IDEC. Maintenance and Inspection Inspection Items Inspection Method Inspections Enclosure base Visual Tightening bolt, screws Visual, tactile Packings Visual Connecting parts Visual, tactile Temperature rise Thermometer, tactile No rusting No damages No loosening No rusting No cracks No apparent deformation No loosening of screws No dirt on insulation materials Surface temperature 80ºC max. Measures Cleaning Rust-resistant treatment Tightening Cleaning Replacement Tightening Cleaning Investigate the cause Disposal Observe laws and regulations set by each country concerning refuse disposal. Safety Precautions EU2B Control Units Use EU2B switches that are applicable for use in hazardous areas (potentially explosive atmosphere where explosive gas or vapor may exist), otherwise explosion or fire hazard may result. • EU2B switches can be installed only in zones 1 and 2. Do not use in zone 0. • Turn power off to the EU2B switches before installation, removal, wiring, or maintenance, otherwise explosion, fire hazard, or electric shock may result. • Do not disassemble, repair, or modify, otherwise damage or accident may result. • Do not use damaged EU2B switches, otherwise damage or accident may result. • When connecting external devices, make sure that each cable is connected to the correct terminal, otherwise electric shock, fire hazard, or explosion may result. • Use wires of a proper size to meet voltage and current requirements. Incorrect wiring may cause abnormal temperature rise and lead to fire hazard and explosion. • Connect the grounding terminal to a proper ground, otherwise electric shock, fire hazard, or explosion may result. • Operate the EU2B switches at the rated current and voltage specified in this catalog, otherwise short-circuiting, fire hazard, or explosion may result. • Stop operation immediately if abnormal operation occurs. Otherwise, a secondary accident may occur. • Use explosion-proof electrical equipment that are applicable for use in hazardous areas (potentially explosive atmosphere where explosive gas or vapor may exist), otherwise explosion or fire hazard may result. 15 EC2B 1-column Control Box Specification Sheet TO: IDEC Corporation Company: TEL: Contact Person: FAX: No. of Control Box Select the required specifications by checking the checkboxes, and specify the details. Control box size £ EC2B-110 £ EC2B-210 £ EC2B-310 £ EC2B-410 NP Nameplate NP 1 E1 Nameplate (NP) £ No nameplate £ EC2B-510 NP NP 1 1 2 2 E1 NP 1 1 2 2 3 3 3 E1 4 4 5 E2 E2 Material: Acrylic (53 mm × 12 mm, plate thickness 2 mm) Legend color: black letter, white background Maximum no. of letters: 19 letters per line (up to 2 lines) £ 1 line 1st line £ 2 lines 2nd line Control Units Position Control Unit Part No. Control Unit Nameplate 1 £ ON £ OFF £ START £ OFF ON £ HAND AUTO £ HAND OFF AUTO £ STOP £ No nameplate £ Specify letters ( 2 £ ON £ OFF £ START £ OFF ON £ HAND AUTO £ HAND OFF AUTO £ STOP £ ON £ OFF £ START £ OFF ON £ HAND AUTO £ HAND OFF AUTO £ OFF £ START £ OFF ON £ HAND AUTO £ HAND OFF AUTO £ EMERGENCY STOP £ Blank ) £ ON £ OFF £ START £ OFF ON £ HAND AUTO £ HAND OFF AUTO £ STOP £ EMERGENCY STOP £ Blank ) EC2B-110, 210, 310 EC2B-110, 210, 310 Code Cable lead-in method E1 Reducer With specification • Specify wiring diagram when wiring is required. EC2B-410, 510 NPT 3/4 UL/c-UL, IECEx/ATEX certified • £ Blank £ STOP £ No nameplate £ Specify letters ( Without specification (standard reducer) £ EMERGENCY STOP ) £ ON Lead-in Fitting (E1/E2) £ Blank £ STOP £ No nameplate £ Specify letters ( 5 £ EMERGENCY STOP ) £ No nameplate £ Specify letters ( 4 £ Blank ) £ No nameplate £ Specify letters ( 3 £ EMERGENCY STOP Check £ £ £ £ £ £ £ Specification NPT 1 EC2B-410, 510 Cable lead-in method Code M16 M20 M25 M32 E2 Reducer NPT 1/2 NPT 3/4 Check £ £ £ £ £ £ Specification M25 M32 M40 NPT 3/4 NPT 1 NPT 1 1/4 NPT 1 • Specify when other accessories are required. IDEC Corporation • 1175 Elko Drive • Sunnyvale, CA 94089 • 800-262-IDEC (4332) • Fax: 408-745-5258 • www.IDEC.com/usa ©2017 IDEC Corporation. All Rights Reserved. EU9Y-DS100-2a pdf only 1702062102 16
EC2B-B21B011N2-U 价格&库存

很抱歉,暂时无法提供与“EC2B-B21B011N2-U”相匹配的价格&库存,您可以联系我们找货

免费人工找货