0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
HW4S-2TF10

HW4S-2TF10

  • 厂商:

    IDEC

  • 封装:

  • 描述:

    METAL KNOB

  • 数据手册
  • 价格&库存
HW4S-2TF10 数据手册
A A1: Safe Break E-Stops • World’s Safest E-Stops XA Ø 16mm & New XW Ø 22mm . . . . . . . . . . . . . . . A1-14 A2: ø16mm Switches & Pilot Devices • A6 Series Ø 16mm. . . . . . . . . . . A2-17 • L6 Series Ø 16mm . . . . . . . . . . . A2-30 A3: ø22mm Switches & Pilot Devices • HW Series Ø 22mm. . . . . . . . . . A3-52 • LW Series Ø 22mm . . . . . . . . . A3-108 • TW Series Ø 22mm . . . . . . . . . A3-126 A4: ø30mm Switches & Pilot Devices • TWTD Series Ø 30mm . . . . . . A4-166 • Cam - CS Series . . . . . . . . . . . A4-195 • Mono Lever - ARN Series . . . A4-202 A5: Miniature Switches & Pilot Devices • A8 Series Ø 8mm. . . . . . . . . . . A5-205 • AP Series Miniature Pilot Lights Ø 8-16mm . . . . . . . . . . . . . . . A5-210 New on shbutt le. u P l a HW Du now availab es Switch page A3-84. See www.idec.com/switches Additional Web Resources • New and updated product information • Downloadable software demos & upgrades • Part configuration tool & cross reference • Online stock check & ordering • IDEC field sales & distributor search • Online literature request • Downloadable manuals & CAD drawings • Manufacturer’s suggested retail price list • Product training schedule & locations • Advertising & trade show schedules • Press releases & FAQs www.idec.com/switches for more information on this product family visit Switches & Pilot Devices Section Section A Overview • Selection Guide . . . . . . . . . . . . A-2 • General Information . . . . . . . A-12 Switches & Pilot Devices Selection Guide Selection Guide A1: Safe Break E-Stops: 16mm XA & 22mm XW Series World’s Safest Emergency Switches Switches & Pilot Devices A Series Model XA XW NEW NEW Appearance See Page A1-14 Non-illuminated E-Stops: Pushlock/Turn Reset, Push-Pull Operator Type Reset Action A1-14 Illuminated & Non-Illuminated E-Stops: Pushlock/Turn Reset, Push-Pull Pushlock Pull or Turn Reset (both actions available in each switch) Contact Configuration 1NO - 1NC, 2NC, 1NO-3NC, 4NC Electrical Life 1NO - 1NC, 2NC, 1NO-3NC, 4NC 100,000 Minimum 250,000 or more (24V AC/DC 100mA) Mechanical Life 250,000 Minimum Termination PCB & Solder Terminals Degree of Protection Screw Terminals IP65 (IEC60529) Approvals XA series UL recognized. A-2 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide A2: Ø16mm Switches & Pilot Devices - A6 Series AL6 Series Model AB6 AL6 AB6 AB6-V AS6 AS6-K A See Page A2-20 A2-18 Non-Illuminated Pushbuttons: • Momentary • Maintained A2-20 A2-18 Operator Type Illuminated Pushbuttons: • Momentary • Maintained • Pilot Lights Oversize Lens Illuminated Pushbuttons: • Momentary • Maintained Oversize Button Non-illuminated Pushbuttons: • Momentary • Maintained Bezel/Lens Shape & Size Round: 18mm Square: 18mm Rectangular: 18 x 24mm Light Source LED Lens/Button Colors Amber, Green, Red, White, Yellow, Blue Contact Configuration SPDT or DPDT (Gold-Clad Silver Contact) Contact Ratings 120V AC/1A, 24V DC/1A (Resistive) (Minimum applicable load reference value: 5V AC/DC, 1mA) Electrical Life Round: 23.5mm Square: 23.5mm Rectangular: 17.5 x 23.5mm — Black, Blue, Green, Red, White, Yellow LED A2-18 Black, Blue, Green, Red, White, Yellow A2-24 Keylock Switches: • 2 or 3-Position • Maintained or Spring Return • Key removable options Emergency Stop: • Pushlock / Turn Reset Selector Switches: • 2 or 3-Position • Maintained or Spring Return Round: 23.5mm Round: 18mm Square: 18mm Rectangular: 18 x 24mm — Amber, Green, Red, White, Yellow, Blue A2-24 — — — Red Black Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum 100,000 operations 100,000 operations minimum (at 1,200 operations/hour) Mechanical Life Momentary: 1,000,000 operations minimum Maintained: 100,000 operations minimum 100,000 operations 250,000 operations minimum Degree of Protection Enclosed/Dustproof: IP40 Waterproof/Oiltight/Corrosion Resistant: IP65 Termination .110" Solder/Quick Connect Approvals UL Recognized File No. E55996 CSA Certified File No. LR48366 — Certificate No. 2030010305027380 1. LED lamps contain a built-in current-limiting resistor and reverse polarity protection diode. 2. Available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-3 Switches & Pilot Devices Appearance Switches & Pilot Devices Selection Guide A2: Ø16mm Switches & Pilot Devices - L6 Series Series Model LA∆B/HA∆B LA∆P/HA∆P LA∆L/HA∆L HA1B-V/ HA1E-V LA∆S/HA∆S LA∆K/HA∆K LA∆F/HA∆F A2-38 A2-40 A2-42 LA3Z/LA1T/ HA1R Switches & Pilot Devices A Appearance Direct Opening Action See Page Operator Types A2-30 A2-34 Non-illuminated: • Momentary • Maintained Pilot Light • LED/Incan. Rnd: 18mm Rnd: 18mm A2-36 Illuminated: • Momentary • Maintained • LED/Incan. A2-33 E-Stop • Pushlock/ Turn Reset Rnd: 18mm Sq: 18mm Rect: 18 x 24mm Rnd: 25mm Ovrsze Rnd: 24mm Ovrsze Sq: 24mm Ovrsze Sq: 24mm Ovrsze Sq: 24mm LED: 5VDC/6V, 12V, LED: 5VDC/6V, 24V AC/DC 12V, 24V AC/DC – – Light Source Incan: 5V/6V, 12V, Incan: 5V/6V, 12V, 24V AC/DC 24V AC/DC Green, Green, Lens/Button Amber, Green, Red, Amber, Red, Blue, White, Amber, Blue, White, Red Blue, White, Yellow Red, Colors Yellow Yellow DPST-NC Contact SPDT, DPDT – SPDT, DPDT (positive Configuration action) 100,000 Electrical Incan: 2000 hrs operations min Life (at full rated load) LED: 50,000 hrs Selector Switch • 2 pos/ 3pos • Spring/Maint Momentary: 2,000,000 Maintained: 250,000 – Degree of Protection Termination Approvals A-4 Momentary: 2,000,000 Maintained: 250,000 Illuminated Selector • 2 pos/ 3pos • Spring/Maint • LED/Incan. Rnd: 18mm Sq: 18mm Rect: 18 x 24mm Ovrsze Rnd: 24mm 18mm Sq: 18mm Bezel Shape Sq: Rect: 18 x 24mm Rect: 18 x 24mm and Size Ovrsze Rnd: 24mm Ovrsze Rnd: 24mm Mechanical Life Key Switch • 2pos/3pos • Spring/Maint • Key Remove Option – – Black/White Black/Silver DPDT 100,000 operations min (at full rated load) BZR: 18 x 24mm Lvr: 18mm PB/Selector: 25mm LED: 5VDC/6V, 12V, 24V AC/DC Incan: 5V/6V, 12V, 24V AC/DC Amber, Green, Red, Blue, White, Yellow – – DPDT – Momentary: 2,000,000 Maintained: 250,000 250,000 operations A2-33, A2-44 Piezo Buzzer Lever Switch • 2 pos/ 3pos • Spring/Maint PB/ Selector • 2 pos/ 3pos – IP65 0.110”solder/quick connect, PCB pins UL Recognized File No. E55996 www.idec.com CSA Certified File No. LR21451 Reg.No. R9551089 Reg. No. J9551458 Reg. No. J9650511 HA1B-V, HA1E only USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide A3: Ø22mm Oiltight Switches and Pilot Devices - HW Series HW∆B– Series Model HW∆P– HW∆L– HW1B, HW1E Push–Pull HW1S, HW1K, HW1F– HW7D, HW1M, HW1R - Flush Flush A Pushlock Turn Reset Knob Operator Switches & Pilot Devices Extended NEW Dome Lens Flush (metal bezel) Dual Pushbutton Pushlock Turn Reset Knob Operator (metal bezel) Extended (metal bezel) Dome Lens (metal bezel) Pushlock Turn Reset (metal bezel) Extended Mono-Lever 40mm Mushroom Key Operator Flush Lens Appearance Extended/Shroud Pushlock Key Reset Square Flush Square Flush 40mm Mushroom Jumbo Pushlock Turn Reset Key Operator (metal bezel) Pushbutton Selector Square Extended Illuminated Unibody E-Stop Square Extended Jumbo Mushroom Illuminated Unibody E-Stop See Page A3-54 A3-61 A3-64 A3-52 Illuminated Pushbuttons: • Momentary • Maintained • LED/Incandescent E-Stops: • Modular or Unibody • Non-Illuminated • Illuminated (unibody only) • key reset (all units meet EN418) Operator Types Non-illuminated Pushbuttons: • Momentary • Maintained Contact Configuration Modular: (NO, NC, NO-EM, NC-LB (maximum 6 contacts) Electrical Reliability MTBF < 1 fault in 10 million operation cycles (3V DC, 5mA) Pilot Lights • LED/Incandescent — Modular: NO, NC, NO-EM, NC-LB (maximum 6 contacts) 2NC, 1NO/1NC (Unibody) A3-68, A3-71, A3-74 A3-84, A3-89, A3-91 Selector Switches • Non-Illuminated • Illuminated • LED/Incandescent • 2, 3, 4, 5- position (key & illum. 2 or 3position only) Modular: NO, NC, NO-EM, NC-LB (maximum 6 contacts) HW7D Dual Pushbutton HW1M Monolever • 2 or 4 position HW1R Selector Pushbutton Modular: NO, NC, NO-EM, NC-LB (maximum 6 contacts) Pushbuttons: 5,000,000 operations minimum (900 operations per hour) Mechanical Life Momentary All other switches: 500,000 Degree of Protection IP65 (from front of the panel), IP20 (type HW-F contact blocks) (conforming to IEC60529) NEMA Type 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS-110) Termination M3.5 screw terminals (fingersafe/spring-up/exposed screw) with captive sems plate HW1R: IP65, IP20 NEMA 1, 2, 3, 3R, 3S, 4, 4x, 5, 12, 13 HW1M: IP40, IP20 Direct Opening Action Approvals UL Listed File No. E68961 www.idec.com CSA Certified File No. LR92374 (NC contacts only) Reg No. R9551089 (E-stops) Reg No. J9551458 (all other switches) Reg No. J9650511 (Pilot Lights) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Certificate No. 2005010305145656 A-5 Switches & Pilot Devices Selection Guide A3: Ø22mm Oiltight Switches and Pilot Devices - LW Series Series Model LW∆B– LW∆L– LW1S– LW1F LW1K LW∆P– Flush Round Switches & Pilot Devices A Extended Round Square Square Flush Square Appearance Round Unibody Square Extended Mushroom Square Unibody Mushroom See Page Operator Type Contact Configuration A3-110 A3-112 Non-Illuminated Pushbuttons • Momentary • Maintained Illuminated Pushbuttons: • Momentary • Maintained • LED/Incan. A3-116 Selector Switch: • 2 or 3- position A3-116 Illuminated Selector: • 2 or 3- position • LED/Incan. A3-116 Key Selector: • 2 or 3- position • Key removable options A3-114 Pilot Light • LED/Incan. • Standard/ Unibody SPDT, DPDT, 3PDT — Gold-clad crossbar contacts 30VDC/1A, 125VAC/1A resistive Contact Ratings Mechanical Life Momentary: 1,000,000 operations minimum, Maintained: 500,000operations, Selectors: 250,000 operations minimum Electrical Life (at rated load) Momentary: 100,000 (1800 operations/hour) Maintained: 100,000 (900 operations/hour) Degree of Protection (conforming to IEC529) Oiltight/watertight: IP65 Termination •.110" solder/quick connect • PCB (gold contacts only) • M3 screw (2 pole only) Approvals — Silver Contacts 30VDC/2A, 125VAC/3A, 250VAC/2A resistive 30VDC/1A, 125VAC/2A,250VAC/1.5A inductive UL Recognized File No.E55996 — IP65 CSA Certified File No. LR21451 Reg. No. J9551801 1. Lamps not included in assembled units. 2. Available as assembled or sub-assembled components. A-6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide A3: Ø22mm Oiltight Switches and Pilot Devices - TW Series Series Model A∆W... A∆LW... Flush ASW... ASLW... APW... Extended A Extended/Shroud Switches & Pilot Devices Extended Dome Lens Knob Operator Mushroom Flush Lens Mushroom Lever Operator Appearance Square Flush Knob Operator (w/transformer) Square Flush Square Extended Key Operator See Page Square Flush (w/transformer) Square Extended Push-Pull Pushlock Turn Reset Pushlock Turn Reset A3-128 A3-138 Illuminated Pushbuttons: • Momentary • Maintained • E-Stop • LED/Incandescent A3-142 Selector Switches: • 2, 3, 4, 5-position • Maintained • Spring Return • Colored knobs/ inserts Operator Types Non-illuminated Pushbuttons: • Momentary • Maintained • E-Stop Contact Configuration Modular: NO,NC, NO-EM, NC-LB (maximum 6 contacts) Contact Ratings 10A thermal current/600V maximum Electrical Life 500,000 operations/min Mechanical Life Momentary Pushbuttons: 5,000,000 operations minimum; Others: 500,000 operations minimum Selector Switches: 500,000 operations minimum Degree of Protection NEMA Type 1, 2, 3, 3R, 4, 4X, 5, 12, 13; Waterproof/Oiltight/Corrosion Resistant: IP65 Termination M3.5 Screw Terminals with captive sems plate Approvals UL Listed File No. E70646 A3-146 Illuminated Selectors: • Full Voltage/ Transformer • LED/Incandescent See Contact Arrangement Charts page A3-150. A3-135 Pilot Lights: • Full Voltage/ Transformer • LED/Incandescent — Direct Opening Action CSA Certified File No. LR48366 File No. 9561116E01 (NC contacts only) Certificate No. 2030010305027380 1. Illuminated units include lamp. 2. Available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-7 Switches & Pilot Devices Selection Guide A4: Ø30mm Oiltight Switches and Pilot Devices - TWTD Series Series Model A∆D... A∆LD... ASD... A∆LD... APD... Flush Extended Switches & Pilot Devices A Extended/ Neoprene Boot Knob Operator Extended/Shroud Knob Operator (full voltage) Dome Lens Mushroom Lever Operator Mushroom Appearance Knob Operator (with transformer) Jumbo Mushroom Dome Lens (w/transformer) Key Operator Pushlock Turn Reset Pushlock Turn Reset Push-Pull Push-Pull See Page A4-168 A4-174 Illuminated Pushbuttons: • Momentary • Maintained • Special (E-Stop) • LED/Incandescent A4-179 Selector Switches: • 2, 3-position • Maintained • Spring return • Key removable options A4-182 Operator Type Non-illuminated Pushbuttons: • Momentary • Maintained • E-Stop Contact Configuration Modular: NO, NC, NO-EM, NC-LB (maximum 6 contacts) Contact Ratings 10A thermal current 600V maximum — Electrical Life 500,000 operations minimum (pushbuttons and selector switches) Operating Frequency: 30 operations/minute, Duty Rate 40% — Mechanical Life Momentary Pushbuttons: 5,000,000 operations minimum; Others: 500,000 operations minimum Degree of Protection NEMA Type 1, 2, 3, 3R, 4, 4X, 5, 12, 13 Waterproof/Oiltight/Corrosion Resistant: IP65 Termination M3.5 Screw Terminals with captive sems plate See Contact Arrangement Charts on page A4-185. Approvals UL Listed File No. E70646 Illuminated Selectors • LED/Incandescent • 2, 3-position • Maintained • Spring return A4-174 CSA Certified File No. LR48366 File No. DK95-00717 Pilot Lights • Full Voltage/ Transformer • LED/Incandescent — Certificate No. 2005010305145656 1. Illuminated units include lamp. 2. Available as assembled or sub-assembled components. A-8 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide A4: Ø30mm Switches - Cam and Mono-Lever Series Model ACSNO Mounting Hole Diameter ACSNK UCSQO Ø 1–13/64" (30mm) UCSQM 5 hole panel cutout ARN Ø 1 13/64" (30mm) Standard Knob (ARNO) A Switches & Pilot Devices Short Knob (ARNSO) Appearance Interlock knob (ARNLO) See Page A4-195 Operator Types Cam Switch w/knob selector Cam Angles and/or Positions 30° 45° 60° 90° Contact Ratings 10A thermal current 600V insulation voltage Electrical Life: 500,000 operations minimum (at full rated load) Mechanical Life 500,00 operations minimum Degree of Protection IP65, NEMA 4, 13 Termination M3.5 Screw Terminals with captive sems plate Approvals Cam Switch w/key selector Up to 12 positions Up to 8 positions Up to 6 positions Up to 4 positions IP40 A4-202 Cam Switch w/knob & mechanical indicator. Cam Switch 3-pos, spring-return Mono-lever Switch Spring-return 45° 3 position only • Center + 2, 3, or 4 position • Maintained • Spring return IP65, NEMA 4, 13 UL Listed File No. E68961 IP40 CSA Certified File No. LR48366 1. Cam switches available only as assembled units. 2. Mono-lever switches available as assembled or sub-assembled components. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-9 Switches & Pilot Devices Selection Guide A5: Miniature Switches and Pilot Devices - Ø8mm A8 Series Series Model AL8 AB8 Switches & Pilot Devices A Appearance See Page A5-205 A5-205 Operator Type Illuminated Pushbuttons: • Momentary • Maintained • Pilot Lights Non-Illuminated Pushbuttons: • Momentary • Maintained Lens Shape and Size Round: Ø 0.351 (9mm) Square: ❏ 0.351 (9mm) Rectangular: 0.351 x 0.468 (9 x 12mm) Light Source LED Lens/Button Colors Amber, Green, Red, White, Yellow Contact Configuration SPDT (Gold-Clad Silver Contact) Contact Ratings 120V AC/1A, 24V DC/1A, (Resistive), Minimum applicable load reference value: 5V AC/DC, 1mA Electrical Life (at full rated load) Momentary: 100,000 operations minimum Maintained: 50,000 operations minimum Mechanical Life Momentary: 200,000 operations minimum Maintained: 100,000 operations minimum Degree of Protection Enclosed/Dustproof: IP40 Termination Solder Tab Terminal — UL Recognized File No. E55996 Approvals Black, Blue, Green, Red, White, Yellow CSA Certified File No. LR21451 1. LED lamps require an external current limiting resistor. 2. Available as assembled units only (replacement LED lamps available). A-10 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide A5: Miniature Pilot Lights - Ø8 to 16mm AP Series Series Model AP8M AP1M AP2M Mounting Hole Diameter 8mm 10mm 12mm Dome 16mm Dome Dome Dome AP6M A Flat Flat Flat See Page Flat A5-211 Operator Type Lens Shape and Size Pilot Lights Flat & Dome Ø 9.8mm Flat & Dome Ø 12mm Flat & Dome Ø 14mm Light Source LED (with built-in current limiting resistor) Lens Colors Amber, Green, Red, White, Yellow Voltages 6, 12, 24V DC (Full Voltage) 6V DC/18mA 12V DC/11mA 24V DC/12mA 6V DC/18mA 12V DC/11mA 24V DC/12mA Degree of Protection Enclosed/ Dustproof: IP40 Waterproof/Oiltight/Corrosion Resistant: IP65 Approvals 6V DC/33mA 12V DC/22mA 24V DC/11mA Solder Tab UL Recognized File No. E68961 Flat & Dome Ø 18mm 6, 12, 24V DC (Full Voltage); 120, 240V AC (with transformer); 110V DC (with DC-DC converter). Rated Current Termination Switches & Pilot Devices Appearance 6V DC/33mA 12V DC/11mA 24V DC/11mA .110" Solder/Quick Connect CSA Certified File No. LR48366 1. Only AP6 accepts.110" quick-connect. 2. AP2 and AP6 compatible with snap-on transformers. 3. All units are one-piece pilot lights with non-replaceable LED lamp. 4. All units include built-in current limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-11 Switches & Pilot Devices General Information General Information Information About LED Lamps A Switches & Pilot Devices Light-emitting diodes (LEDs) are P–N junction semiconductors with mechanisms called “junction electro-luminescence.” Application of direct current results in radiation or emission of a monochromatic light. Specifications Different semiconductor materials produce different wavelengths of light as shown below: Green Gallium Phosphide (GaP) 5600 Å Yellow Gallium Arsenide Phosphide (GaAsP) 5800 Å Amber Gallium Arsenide Phosphide (GaAsP) 6300 Å Red Gallium Arsenide Phosphide (GaAsP) 6600Å Infrared Gallium Arsenide (GaAs) 9000 Å Advantages of Using LEDs • LEDs are used when heat generated by incandescent lamps would damage nearby equipment or interfere with a precision process. This is particularly advantageous when multiple lights are grouped. • LEDs can operate at low temperatures which would cause incandescent lamps to fail, since glass cracks during rapid cooling. • LEDs consume 50 times less power than incandescent lamps, thereby reducing energy consumption. • LEDs last 500 times longer than incandescent lamps. LEDs average a million hours (114 years) while incandescent lamps average 2000 hours. • LEDs do not generally “blow out” unless subjected to a severe overvoltage. They exhibit a half-life type dimishment in brightness over time. After 50,000 hours (6 years) of use, IDEC LEDs will retain approximately half of their original intensity. • IDEC’s SUPERBRIGHT LEDs have high visibility. • LEDs require little or no maintenance because of long life and high reliability. IDEC Recommendations For optimum results, especially when using switches and pilot lights in operating environments which are conducive to overheating, use IDEC LED illuminated units. Transformers are available for use with incandescent illuminated units, which operate at lower voltages to avoid overheating. When IDEC’s L-120L lamp is used, make sure ambient temperatures do not exceed 30˚C (86˚F). If a lamp from another supplier is used, it should be rated for less than 1.8 watts (15mA at 120V AC), with ambient temperatures as stated above. Information About Incandescent Lamps Filament-type incandescent lamps operate within the following parameters. Light output and life expectancy depend on operating voltage. Light output varies to the 3rd or 4th power of the voltage. Life expectancy varies inversely to the 12th power of voltage. In other words, over-voltage of 5% reduces life expectancy by 50%. Under-voltage of 5% doubles life expectancy at the price of light output efficiency. Inrush current (initial current through the filament) has an adverse effect on life expectancy. Cold resistance (room temperature) will have a more detrimental effect than hot resistance to inrush current. Life expectancy of incandescent lamps can be maximized by reducing occurrences of cold resistance to inrush current. Continued intermittent flashing will significantly reduce life expectancy. When using an incandescent lamp with a tungsten filament, flashing will not reduce life expectancy as long as light output does not exceed that of steady burning. When an incandescent lamp must withstand shock and vibration, use low voltage/high amperage (5–6V/60–120mA) lamps. These lamps have a short, thick filament with a high resonant frequency. Provide cooling by using a heat sink, particularly when multiple incandescent lamps are grouped or when air circulation is limited. Make sure ambient temperatures do not exceed 100˚C (212˚F) for maximum life of incandescent lamps. A-12 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Switches & Pilot Devices Selection Guide Comparison: LED vs. Incandescent Lamps Incandescent Heat Dissipation Very Low High Life Expectancy Very Long Short Reliability Very High Low Mechanical Strength Not Susceptible Susceptible to Shock/Vibration Maintenance Required Negligible Frequent Operation at Low Temps. Possible Not Possible Inrush Current Negligible Very Large Voltage Effects on Life Insignificant Significant Brightness Slightly Less Slightly More A Switches & Pilot Devices Characteristics Superbright LEDs Ordering Information 1. IDEC offers assembled and sub-assembled switches and pilot lights for your convenience. In some cases there is a cost difference, with sub-assembled units costing slightly less. Since assembled units are custom made to your order, a couple of days for assembly is added to delivery. To minimize delivery or inventory requirements, it is suggested that switches and pilot lights be ordered as sub-components. 2. When ordering pilot lights or illuminated pushbuttons, make sure to specify the color code in place of the asterisk in the part number, (LED or incandescent lamp included). Spare lamps can be ordered and are listed with sub-assembly components. 3. Accessories, such as locking ring wrench, lens removal tool, and lamp holder, are available to make installation and assembly easier. IDEC recommends using these accessories and is not responsible for damage as a result of using the wrong tool. 4. Marking plates are available for switches and pilot lights which feature a flat lens. Printed mylar (not included) can also be inserted under lens for labeling purposes. 5. Nameplates are available for TW, 7/8" (22mm), HW 7/8" (22mm),and TWTD series, Ø1–13/64" (30mm). For prompt delivery, order standard legends. Custom engraving is also offered for an additional charge. Installation and Operation 1. Use the appropriate lamp holder to remove or install LED or incandescent lamps. Using pliers will damage the lamp. 2. When mounting switches and pilot lights into a panel, use locking ring wrench. Using pliers or tightening excessively will damage the locking ring. 3. A series, 21/64" (8mm), can be mounted on a panel 0.019" (0.5mm) to 0.236" (6mm) thick. 4. TW, 7/8" (22mm) and TWTD series, Ø1–13/64" (30mm), feature an adjustment ring for mounting on a panel 0.038" (1mm) to 0.236" (6mm) thick. Using a nameplate or an anti-rotation ring adds 0.031" (0.8mm) to the panel thickness. 5. When applicable, solder terminals within 20W/5sec or 260˚/3sec without exerting external force to the terminals. Use a non-corrosive resin liquid flux. 6. The operating voltage for LED units represents a complete DC value. When using a pulsing voltage, such a full-wave rectification, keep peak currents within the forward current If. Peak currents exceeding If may shorten the life of the LED lamp. 7. To avoid a short circuit, never connect NO and NC contacts to different voltages or power sources. 8. Optimum performance of TW and TWTD illuminated pushbuttons, selector switches, and pilot lights is obtained with IDEC LED and incandescent lamps. 9. For maximum life of incandescent lamps (approximately 2000 hours), use within the rated operating voltage. If it is necessary to use a higher voltage, keeping ambient temperature below 30˚C (86˚F)will help prolong the life of an incandescent lamp. If excessive voltage is applied (over 50V), the lamp may blow and the lens holder may pop out. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A-13 Safe Break E-Stops World’s Safest Emergency Stop Switches 16mm XA & 22mm XW E-Stops XA & XW Series, The Safe Break Action E-Stops! If the E-Stop is installed incorrectly or shifts in shipment, the contacts and switch can separate, which cause the NC contacts to remain closed during an emergency and the machine to continue running! With IDEC’s revolutionary “Safe Break Action,” the NC contacts will automatically open when the contacts are removed from the operator. This feature places the machine in a non-operational state. OR XA Conforming to Standards Standard Operating Conditions XW IEC60947-5-1, EN60947-5-1, IEC60947-5-5, EN60947-5-5, JIS C8201-5-1, UL508, CSA C22.2 No.14 Non-illuminated: -25 to +60˚C Without Freezing Illuminated: -25 to +55˚C Without Freezing Operating Temperature 45 to 85%RH Without Condensing Operating Humidity -45 to +80˚C Storage Temperature Operating Force Minimum Force to Latch Maximum Travel to Latch Maximum Travel Specifications Switches & Pilot Devices A1 Key features of the XA and XW E-Stops include: • Lead-free (RoHS compliant) • The depth behind the panel is only 48.7mm for 4 contacts (XW Series) • IDEC’s original “Safe Break Action” ensures the contacts open if the contact block is separated from the operator • Pushlock Reset and Push-Pull in the same switch • Direct opening action mechanism (IEC60947-5-5, 5.2, IEC60947-5-1, Annex K) • Safety lock mechanism (IEC60947-5-5, 6.2) • Degree of protection IP65 (IEC60529) • Screw terminal is finger-safe (IP20) • Two button sizes: 40mm and 60mm (XW Series) • Rated Insulation Voltage - 16mm 300V, 22mm 250V • Rated Thermal Current 5A • UL, c-UL Listed, CE marked (XA Series UL recognized) Pushlock: 10.5N, Pull Reset: 10N, Turn Reset: 0.16N-m Pushlock: 32N, Pull Reset: 21N, Turn Reset: 0.27N-m 60N 80N 4.0mm 4.5mm Operating Extremes: 150m/s2 (15G) Damage Limits: 1000m/s2 (100 G) Shock Resistance 10 to 500Hz, Amplitude 0.35mm Acceleration 50m/s2 (5G) 10 to 500Hz, Amplitude 0.35mm Acceleration 50m/s2 (5G) Vibration Resistance Life Mechanical Electrical 250,000 Minimum 100,000 Minimum 250,000 or more (24V AC/DC 100mA) Degree of Protection Short-Circuit Protection Terminal Shape Solder Terminal, PCB Terminal M3 Screw Terminal Applicable Wire Size Solder/PCB Terminal: 1.25mm2 Maximum Screw Terminal: 0.75 to 1.25mm2 (AWG 18 to 16) Soldering Recommended Terminal Torque Weight (Approx.) A1-14 www.idec.com IP65 (IEC60529) 250V/10A Fuse (Type aM IEC60269-1/IEC60269-2) (AWG 16 Maximum) 20W/5sec Maximum, 260ºc/3sec Maximum — 40mm Button: 28 grams — 0.6 to 1.0N-m 40mm Button: 72 grams, 60mm Button: 81 grams USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC World’s Safest Emergency Stop Switches Safe Break E-Stops XA & XW Series (assembled) Part Numbers: 16mm XA Mushroom Button E-Stop Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XA1E-BV411V-R 2NC XA1E-BV402V-R 1NO-3NC XA1E-BV413V-R 4NC XA1E-BV404V-R 1NO - 1NC XA1E-BV411-R 2NC XA1E-BV402-R 1NO-3NC XA1E-BV413-R 4NC XA1E-BV404-R A1 40mm Mushroom Switches & Pilot Devices PCB Terminals Solder Terminals Part Numbers: 22mm XW LED Illuminated Mushroom Button E-Stop Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XW1E-LV411Q4M-R 2NC XW1E-LV402Q4M-R 1NO-3NC XW1E-LV413Q4M-R 4NC XW1E-LV404Q4M-R Screw Terminals Illumination is with built-in 24V AC/DC LED. Part Numbers: 22mm XW Mushroom Button E-Stops Style Terminal Contacts Part Number 40mm Mushroom 1NO - 1NC XW1E-BV411M-R 2NC XW1E-BV402M-R 1NO-3NC XW1E-BV413M-R 4NC XW1E-BV404M-R Screw Terminals Part Numbers: 22mm XW Jumbo Mushroom Button E-Stops Style Terminal Contacts Part Number 60mm Mushroom 1NO - 1NC XW1E-BV511M-R 2NC XW1E-BV502M-R 1NO-3NC XW1E-BV513M-R 4NC XW1E-BV504M-R Screw Terminals www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A1-15 World’s Safest Emergency Stop Switches Safe Break E-Stops Accessories Part Numbers: Nameplates HWAV–Yellow Plastic Part Numbers: 22mm E-Stop Shrouds Style Part Number A1 OD ID Switches & Pilot Devices HW9Z-KG1-TK2120 Style XA Part Number ID OD HW9Z-KG2-TK2120 16mm Blank ø60mm HAAV4-0 16mm 60mm 16mm “Emergency Stop“ ø60mm HAAV4-27* 16mm 60mm XW 40mm 22mm Blank ø60mm HWAV-0 22mm 60mm 22mm “Emergency Stop“ ø60mm HWAV-27* 22mm 60mm XW 60mm 22mm Blank ø80mm HWAV5-0 22mm 80mm 22mm “Emergency Stop“ ø80mm HWAV5-27* 22mm 80mm 1. Not applicable for 60mm mushroom. 2. Applicable for XW (22mm) series only. *Comes marked “Emergency Stop” as shown. Dimensions XA Dimensions XW Dimensions 0 0 ø4 ø6 Panel Thickness 0.5 to 3.7 Gasket Locking Ring PC Board Layout (Bottom View) Terminal Screw Gasket Locking Ring 19.8 8.7 0.5 ø4 Terminal Cover XA9Z-VL2 0 27.2 19.8 8.7 Panel Thickness 0.8 to 6 s .2 -ø1 le Ho 25.8 3.1 30.4 PC Board Terminal Type 8.7 37 11.2 2.1 19.8 8 Solder Terminal Type 47.2 48.7 Terminal Cover XW9Z-VL2M 3-ø 1.7 Ho les 6.5 20.6 32 32 all dimensions are in mm Connection Diagrams & Panel Cutouts www.idec.com 4 3 1 Right X2 X1 4 3 X2 .2 +0.2 0 3.2 +0.2 0 0 +0.2 0 Left R0 .8 m ax. ø22 .3 +0.4 +0.4 2 1 LED ø16 +0.2 0 24.1 0 X1 X 1.7 4 2 X2 X 3 For Jumbo XW X=Y=70mm 17.9 3 Right 1 4 Left 1 X1 LED 3 +0.4 0 Y Y TOP 4 2 2 LED 2 X2 4 TOP Right 1 1 2 1 3 Right 3 ø22.3 For Standard XW X=Y-50mm 2 Left 2 1 2 Left 2 1 Right A1-16 4 1 2 1 1 2 LED 2 3 TOP 2 Left X1 Right XW + 0 .2 0 ø 1 6 .2 1 Left 2 4 4 1 1 XA TOP 2 2 Right TOP 1 3 Left 2 2 2 1 Right 1 Left TOP 1 1 1 2 2 1 1NO-1NC 2NC TOP 1 1NO-3NC TOP 2 4NC USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series A6 Series — Miniature Switches and Pilot Devices: 16mm Key features of the A6 series switches and pilot lights include: • 16mm (5/8") mounting hole • LED illumination • Compact design saves space • Momentary, Maintained, Selectors, and E-Stops • Gold-clad Silver contacts for reliable low level switching • Snap action contacts • IP40 (dustproof) or IP65 (oiltight) versions Specifications CSA Certified File No. LR21451 Certificate No. 2030010305027380 Degree of Protection IP40: Dustproof IP65 Waterproof/Oiltight/Corrosion Resistant Contact Configuration Maximum Voltage Thermal Current Minimum Applicable Load Contact Material Terminal Style Operating Temperature Operating Humidity Contact Resistance Insulation Resistance Vibration Resistance SPDT, DPDT Shock Resistance Damage limits: 500m/sec2 (approx. 50G) Operating extremes: 200m/sec2 (approx. 20G) Electrical Life 100,000 operations minimum (at full rated load) 250V AC/DC 3A 5V AC/DC, 1mA (subject to operating conditions) Gold-clad silver .110" Solder/ Quick Connect LED Type: -25° to +55°C (no freezing) 45 to 85% RH 50mΩ maximum (initial value) 100MΩ minimum (500V DC megger) 10 to 55Hz, amplitude 1.5mm p-p Maintained: 100,000 operations minimum Momentary: 1,000,000 operations minimum Selector/Keylock: 250,000 operations minimum Switch Unit: 2,000VAC, 1 min. between live/dead part and terminals of different poles; 1,000V AC, 1 minute between terminals of the same pole; 1,500V AC, 1 minute between contact and lamp terminals. Illumination Unit: 2,000VAC, 1 min. between live part/ground Mechanical Life Dielectric Strength LED Lamp Ratings Contact Ratings Switches & Pilot Devices UL Recognized File No.E55996 A2 Soldering Temperature Operating Voltage AC (50/60Hz) DC 20W/5 seconds or 260°C/3 seconds Resistive 120V 240V — 1.0A 0.5A Inductive — 0.7A 0.5A Resistive 1.0A 0.2A — Inductive 0.7A 0.1A — 5V DC ±5% 6V AC/DC (±10%) 12V AC/DC (±10%) 24V AC/DC (±10%) DC: A, R, W, Y: 6mA G, S: 5mA AC: A, R, W, Y: 8mA G, S: 7mA DC: 8mA DC: 8mA 8mA AC: 9mA AC: 9mA Rated Voltage/Current 1. 2. 3. 4. 24V AC Inductive Load, PF = 0.6 – 0.7; DC Inductive Load, L/R = 7ms. Minimum applicable load (reference value) is 5V AC/DC/1mA (applicable range is subject to the operating conditions and load). LED lamp contains a built-incurrent-limiting resistor and a protection diode. LED’s don’t “burn out.” Luminance is reduced to 50% of initial intensity after being lit for 50,000 hours continuously. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-17 Miniature Switches & Pilot Devices ø16mm - A6 Series AB6 Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Style Part Number Momentary Maintained (Latching) Dustproof (IP40) Oiltight (IP65) Dustproof (IP40) Oiltight (IP65) Standard Button Round 18mm SPDT DPDT AB6M-M1-① AB6M-M2-① AB6M-M1P-① AB6M-M2P-① AB6M-A1-① AB6M-A2-① AB6M-A1P-① AB6M-A2P-① SPDT DPDT AB6Q-M1-① AB6Q-M2-① AB6Q-M1P-① AB6Q-M2P-① AB6Q-A1-① AB6Q-A2-① AB6Q-A1P-① AB6Q-A2P-① Square 18mm Rectangular 18mm x 24mm ① Button Color Code SPDT DPDT AB6H-M1-① AB6H-M2-① AB6H-M1P-① AB6H-M2P-① AB6H-A1-① AB6H-A2-① AB6H-A1P-① AB6H-A2P-① Round 23.5mm Oversize Button Switches & Pilot Devices A2 Contact SPDT DPDT – AB6M-M1P-M① AB6M-M2P-M① – SPDT DPDT SPDT DPDT AB6M-A1P-M① AB6M-A2P-M① – AB6Q-M1P-Q① AB6Q-M2P-Q① – AB6Q-A1P-Q① AB6Q-A2P-Q① – AB6Q-M1P-H① AB6Q-M2P-H① – AB6Q-A1P-H① AB6Q-A2P-H① Color Code Black B Green G Red R Blue S White W Yellow Y Square 23.5mm Rectangular 17.5 X 23.5mm 1. In place of ①, specify Button Color Code from the table at the right. 2. To order as sub-assembled, see page A2-19. 3. For accessories, see page A2-25. 4. For dimensions, see page A2-27. Part Numbers: AB6-V Pushlock Turn Reset Shape Operation Contact Part Number Dustproof (IP40) Oiltight (IP65) Pushlock Turn Reset SPDT DPDT AB6M-V1-R AB6M-V2-R Remarks 23.5mm Round Mushroom Part Numbers: Buzzer Style Shape Voltage AB6M-V1P-R AB6M-V2P-R 1. Button available in red only. 2. Replacement button: order AB6M-V-R Part Number 12V DC UZ6-11 24V DC UZ6-12 Round (18mm) A2-18 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series AB6 Non-Illuminated Pushbuttons (Sub-Assembled) Operator + Button = Completed Unit A2 Switches & Pilot Devices Part Numbers: Operators Style Contact Non-Illuminated Pushbuttons SPDT DPDT Part Number Operator Round Square Rectangular Momentary AB6M-M100 AB6Q-M100 AB6H-M100 Maintained AB6M-A100 AB6Q-A100 AB6H-A100 Momentary AB6M-M200 AB6Q-M200 AB6H-M200 Maintained AB6M-A200 AB6Q-A200 AB6H-A200 Part Numbers: Buttons/Lens Description Part Number Button Dustproof (IP40) Oiltight (IP65) Round AB6M-BK1-① AB6M-BK2-① AB6Q-BK1① AB6Q-BK2-① AB6H-BK1-① AB6H-BK2-① Square Rectangular ① Button Color Code Round Oversize – AB6M-BK2-M① Color Code Black B Green G Red R Blue S White W Yellow Y Square Oversize – AB6Q-BK2-Q① – AB6Q-BK2-H① Rectangular Oversize 1. In place of ①, specify Button Color Code from table on right. 2. Buttons which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-19 Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Illuminated Pushbuttons (Assembled) Part Numbers: LED Illuminated Pushbuttons A2 Description Style Contact Part Numbers Momentary Maintained (Latching) Dustproof (IP40) Oiltight (IP65) Dustproof (IP40) Oiltight (IP65) 24V AC/DC ±10% SPDT DPDT AL6M-M14-➁ AL6M-M24-➁ AL6M-M14P-➁ AL6M-M24P-➁ AL6M-A14-➁ AL6M-A24-➁ AL6M-A14P-➁ AL6M-A24P-➁ 24V AC/DC ±10% SPDT DPDT AL6Q-M14-➁ AL6Q-M24-➁ AL6Q-M14P-➁ AL6Q-M24P-➁ AL6Q-A14-➁ AL6Q-A24-➁ AL6Q-A14P-➁ AL6Q-A24P-➁ 24V AC/DC ±10% SPDT DPDT AL6H-M14-➁ AL6H-M24-➁ AL6H-M14P-➁ AL6H-M24P-➁ AL6H-A14-➁ AL6H-A24-➁ AL6H-A14P-➁ AL6H-A24P-➁ 24V AC/DC ±10% SPDT DPDT – AL6M-M14P-M➁ AL6M-M24P-M➁ – AL6M-A14P-M➁ AL6M-A24P-M➁ 24V AC/DC ±10% SPDT DPDT – AL6Q-M14P-Q➁ AL6Q-M24P-Q➁ – AL6Q-A14P-Q➁ AL6Q-A24P-Q➁ 24V AC/DC ±10% SPDT DPDT – AL6Q-M14P-H➁ AL6Q-M24P-H➁ – AL6Q-A14P-H➁ AL6Q-A24P-H➁ Voltage Switches & Pilot Devices Round 18mm diameter Square 18mm Standard Lens Rectangular 18mm x 24mm Round 24mm diameter Oversize Lens Square 24 mm Rectangular 18mm x 24mm 1. In place of ➁, specify Lens/LED Color Code from table below. 2. Lamps also available in 5V DC, 6V AC/DC or 12 V AC/DC, change “4” using voltage/lamp codes (ie AL6M-M13-➁ uses 12V AC/DC LED). 3. LED lamp is included in unit and contains a current-limiting resistor and a protection diode. (External resistor not required.) 4. To order as sub-assembled, see page A2-21. 5. For accessories, see page A2-25. 6. For dimensions, see page A2-27. A2-20 www.idec.com ➁ Lens/LED Color Code Color Code Voltage Code Voltage Code Amber A 5V DC 1 Green G 6V AC/DC 2 Red R 12V AC/DC 3 Blue S 24V AC/DC 4 White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Illuminated Pushbuttons (Sub-Assembled) Operator + LED Lamp + Lens = Completed Unit A2 Switches & Pilot Devices Part Numbers: Operators Style AL6 Illuminated Pushbuttons Contact SPDT DPDT Part Numbers: Lenses Unit Degree of Dustproof (IP40) Protection Size Standard AL6M-LK1-➁ Part Number Operator Round Square Rectangular Momentary AL6M-M100 AL6Q-M100 AL6H-M100 Maintained AL6M-A100 AL6Q-A100 AL6H-A100 Momentary AL6M-M200 AL6Q-M200 AL6H-M200 Maintained AL6M-A200 AL6Q-A200 AL6H-A200 Part Number Oiltight (IP65) Standard Oversize AL6M-LK2-➁ AL6M-LK2-M➁ AL6Q-LK1-➁ AL6Q-LK2-➁ AL6Q-LK2-Q➁ AL6H-LK1-➁ AL6H-LK2-➁ AL6Q-LK2-H➁ Round Square Rectangular 1. In place of ➁, specify Lens Color Code from table below. 2. Lenses which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. ➁Lens/LED Color Code Color Code Part Numbers: LED Lamps Appearance Rated Voltage Part Number A 5V DC LATD-5➁ Green G 6V AC/DC LATD-6➁ Red R 12V AC/DC LATD-1➁ Blue S 24V AC/DC LATD-2➁ White W Yellow Y Amber www.idec.com In place of ➁, specify LED Color Code from table at left. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-21 Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Pilot Lights (Assembled) Part Numbers: LED Pilot Lights Description Switches & Pilot Devices A2 Voltage Part Number Dustproof (IP40) Oiltight (IP65) 24V AC/DC AL6M-P4-➁ AL6M-P4P-➁ 24V AC/DC AL6Q-P4-➁ AL6Q-P4P-➁ Round (18mm Lens) Square (18mm Lens) Rectangular (18mm x 24mm Lens) 24V AC/DC AL6H-P4-➁ AL6H-P4P-➁ ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y 1. In place of ➁, specify LED/Lens Color Code. 2. Lamps also available in 5V DC, 6V AC/DC or 12 V AC/DC, change “4” using voltage codes (ie AL6M-P3-➁ uses 12V AC/DC lamp). 3. LED Lamp is included and contains built-in current limiting resistor and reverse polarity protection diode. (no external resistor required) 4. To order sub-assembled, see page A2-23. 5. For accessories, see page A2-25. 6. For dimensions, see page A2-27. 7. For one piece pilot lights and/or dome lens pilot lights, see page A5-210. Voltage Code Voltage Code 5V DC 1 6V AC/DC 2 12V AC/DC 3 24V AC/DC 4 A2-22 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series AL6 Pilot Lights (Sub-Assembled) Operator + LED Lamp + Lens = Completed Unit A2 Switches & Pilot Devices Part Numbers: Operators Part Number Style Round Square Rectangular AL6 Pilot Lights AL6M-P00 Part Numbers: Lenses Unit Degree of Protection Dustproof IP40 AL6Q-P00 AL6H-P00 Pilot Lights Oiltight IP65 AL6M-LK1-➁ AL6M-LK3-➁ AL6Q-LK1-➁ AL6Q-LK3-➁ AL6H-LK1-➁ AL6H-LK3-➁ Round Square Rectangular 1. In place of ➁, specify Lens Color Code from table below. 2. Lenses which are rated IP65 include a waterproof rubber gasket. 3. For accessories, see page A2-25. ➁Lens/LED Color Code Color Code Part Numbers: LED Lamps Appearance Rated Voltage Part Number Amber A 5V DC LATD-5➁ Green G 6V AC/DC LATD-6➁ Red R 12V AC/DC LATD-1➁ Blue S 24V AC/DC LATD-2➁ White W Yellow Y www.idec.com In place of ➁, specify LED Color Code from table at left. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-23 Miniature Switches & Pilot Devices ø16mm - A6 Series AS6 Selector and Keylock Switches (Assembled) Part Numbers: AS6 Selector Switches and Keylock Switches (2- & 3- Position) Round Selector Square Selector 3-Position 45° 2-Position 90° Round Keylock Maintained 3-Position 45° 2-Position 90° Rectangular Selector Spring Return Right Spring Return Right ➛Center Spring Return Left➛Center L R L L L L 2-Way Return➛Center L Maintained L Spring Return to Right Spring Return Right➛Center Spring Return Left ➛Center R C C C C L L R R R R L L R R C R C R C R 2-Way Return➛Center L Maintained L R Spring Return Right L R Maintained Rectangular Keylock Keylock Switches Contact Operations (for all selectors) AS6M-2Y2P Operator Position and Contact Operation AS6M-2KT2P① Left Left Maintained Square Keylock Selector Switches Contacts Maintained 3-Position 45° Switches & Pilot Devices A2 Function 2-Position 90° Style L Spring Return Right ➛Center L Spring Return Left➛Center L 2-Way Return➛Center L C R C R C R C R C R AS6M-21Y2P AS6M-21KT2PB 2-pos. (DPDT) AS6M-32Y2P AS6M-33Y2P NO AS6M-31KT2P① AS6M-32KT2P① NO NC Left Center NO NC Left Right NO NC NO NC Right Left 3-pos. (DPDT) NO Right NC AS6M-3KT2P① Left AS6M-31Y2P Right NC Left Right AS6M-3Y2P NO NC NO NC Right NO NC Right NO NC AS6M-33KT2PD ①Key Retention Codes AS6Q-2Y2P AS6Q-21Y2P Code Description A Key not retained in any position (removable in all positions) B Key retained in right position only C Key retained in left position only AS6Q-2KT2P① AS6Q-21KT2PB AS6Q-3Y2P AS6Q-3KT2P① D Key retained in left and right (3 position only) AS6Q-31Y2P AS6Q-31KT2P① E Key retained in center only (3 position only) G Key retained right and center (3 position only) H Key retained left and center (3 position only) AS6Q-32Y2P AS6Q-32KT2P① AS6Q-33Y2P AS6Q-33KT2PD AS6H-2Y2P AS6H-2KT2P① AS6H-21Y2P AS6H-21KT2PB AS6H-3Y2P AS6H-3KT2P① AS6H-31Y2P AS6H-31KT2P① AS6H-32Y2P AS6H-32KT2P① AS6H-33Y2P AS6H-33KT2PD 1. For more information on these options, contact your IDEC representative. 2. Key cannot be removed in a spring return position. 1. In place of ①, specify Key Retention Code. See table on right. 2. All models are IP65 and DPDT. 3. Available as assembled units only. 4. For accessories, see page A2-25. 5. For dimensions, see page A2-27. A2-24 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series Accessories — A Series: 16mm Appearance Used With Part Number Ø 5/8" (16mm) units MT-001 Made of metal. Used for tightening plastic locking ring during installation. Tightening torque should not exceed 3kgfcm Ø 31/64" (12mm) AP2M units MT-002 Ø 13/32" (10mm) AP1M units MT-003 Lens Removal Tool Made of metal. Used for removing lens or button from the housing All pushbuttons and pilot lights MT-101 Lamp Holder Tool Made of rubber. Used for removing and replacing LED lamps in illuminated units All illuminated pushbuttons and pilot lights OR-77 Round/Square AL-K6 Switch Guard Prevents inadvertent switch operation. IP40 dust-tight rated. 90 degrees opening maintained Rectangular AL-KH6 Prevents inadvertent switch operation. IP65 oiltight rated 180 degrees opening, spring return Round/Square Rectangular AL-K6SP AL-KH6SP Terminal Cover Made of translucent nylon. Fits over and shields the terminals All 5/8" (16mm) units AL-V6 Dust Cover Fits over the lens or button to provide protection from dust. (not applicable for oversize lenses or buttons) All round units All square units AL-D6 AL-DQ6 All rectangular units AL-DH6 Locking Ring Wrench Description AL-C6 All 5/8" (16mm) units Plug-on terminal adaptor with PCB terminal Mounting Hole Plug Switches & Pilot Devices Plug-on terminal adaptor with solder terminal Adaptor Socket A2 Fills unused panel cutouts. Made of nitrile rubber. Push-in installation from front of panel. IP65 (oiltight) rated. Fills unused panel cutouts. Made of aluminum. Screw-on locking ring from inside of panel. IP65 (oiltight) rated. AL-C6V Rubber AL-B6 Aluminum AL-BM6 LATD-5➁ LATD-6➁ LATD-1➁ LATD-2➁ Replacement LED Lamps LED with built in current limiting resistor (with all illuminated assemblies). 5V DC 6V AC/DC 12V AC/DC 24V AC/DC Replacement Locking Ring Fastens operators to panel (included with all operators). All switches & pilot lights HA9Z-LN Anti-Rotation Ring Prevents rotation of switches in panel (included with all operators). All switches & pilot lights AL6-LP Engraving plates to allow legends underneath translucent lenses (included with all lenses). Round standard Square standard Rectangular standard Round oversize Square/rectangular oversize AL6M-W AL6Q-W AL6H-W AL6M-MW All key selectors AS6-SK Replacement Engraving Inserts Replacement Keys Pair of keys (#132). All key switches use same standard key. AL6Q-QW 1, In place of ➁ specify color code. A=Amber, W=White, G=Green, Y=Yellow, R=Red, S=Blue. 2. LEDs include built-in current limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-25 Miniature Switches & Pilot Devices ø16mm - A6 Series Schematics — A Series: 5/8" (16mm) Terminal Arrangement (Top View) A2 Switches & Pilot Devices Illuminated Pushbuttons NC NC NO NO COM COM (+) Lamp (–) Lamp SPDT Contact (Single-pole/Double Throw) (+) Lamp (–) Lamp DPDT Contact (Double-pole/Double Throw) Non-illuminated Pushbuttons and Selector Switches NC NC NO NO COM COM SPDT Contact (Single-pole/Double Throw) DPDT Contact (Double-pole/Double Throw) IDEC’s Superbright LED Internal Circuit LATD-1,-2,-6 (GS) LED Chip Protective Diode Zener Diode LATD-5 (ARWY) LATD-1,-2,-6 (ARWY) LATD-5 (GS) A2-26 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series Dimensions — A Series: 5/8" (16mm) Pushbuttons, Ø 5/8" (16mm) 2.5 Panel Thickness 0.5 to 6mm Rubber Gasket Anti-rotation Ring Locking Ring Terminal Width 2.8 × 0.5t Square (TOP) Rectangular (TOP) A2 ø18 (TOP) 5 18 Round Switches & Pilot Devices 5 3 1 8 0.6 22 24 5.7 18 9 9 all dimensions are in mm Large Size Lens Rubber Gasket 6 1 0.6 8 9 22 23.5 23.5 17.5 5 6 Round (TOP) Square (TOP) Rectangular (TOP) Locking Ring 3 5 2.5 ø23.5 Terminal Width 2.8 × 0.5 t Panel Thickness 0.5 to 6mm Anti-rotation Ring 0.6 9 15.5 0.6 15.5 12.5 all dimensions are in mm Selector Switches, Ø 5/8" (16mm) Gasket Terminal Width 2.8 × 0.5t 2.5 3 Anti-Rotation Ring Panel Thickness: 0.5 to 6 mm Rectangular (TOP) Locking Ring Square (TOP) Round (TOP) 8 5 18 5 ø1 8 1 8 22 15.5 18 24 all dimensions are in mm Gasket Terminal Width 2.8 × 0.5t 3 Panel Thickness: 0.5 to 6 mm Locking Ring Rectangular (TOP) Square (TOP) Round (TOP) NC 18 5 2.5 Anti-Rotation Ring 5 NO C 1 8 22 26 24 18 ø18 all dimensions are in mm www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-27 Miniature Switches & Pilot Devices ø16mm - A6 Series Dimensions con’t A2 Switch Guard, Ø 5/8" (16mm) Panel Thickness: 0.5 to 5 mm 32 18 23.5 13 26.5 min. 33 R2 2 10.5 26.5 min. 10.5 23.5 13 (45.5 min. for 180° opening type) 24 (45.5 min. for 180° opening type) Switches & Pilot Devices Panel Thickness: 0.5 to 5 mm 34 Gasket 14 Gasket 28 14 (180° opening type) (90°, 110° opening types) 19 min. 28 25 min. Panel Thickness: 0.5 to 5 mm 34 Waterproof Gasket for Switch Guard R2 2 24 45.5 min. 10.5 45.5 min. 10.5 23.5 23.5 13 13 33 18 Gasket 0.4 14 19 min. 25 min. Terminal Sockets Dust Covers AL-C6, 5/8" (16mm), Solder AL-D6, Round Rubber Gasket Terminal Width 2.8 × 0.5t 3 AL-DQ6, Square Panel Thickness 0.5 to 6mm Anti-rotation Ring ❏0.936" (❏24) 1.17" (30) 17.5 5 0.293" (7.5) 6 6 1 8 0.6 9 22 23.5 15.5 Square (TOP) ø23.5 Round (TOP) 23.5 0.6 AL-DH6, Rectangular ❏0.936" (❏24) Rectangular (TOP) Locking Ring 5 2.5 28 9 0.507" (13) 0.012" (0.3) 0.293" (7.5) 0.507" (13) Dust Cover Gasket 0.012" (0.3) 0.293" (7.5) 0.507" (13) Dust Cover Gasket 0.012" (0.3) Dust Cover Gasket Panel Cut-Outs For Units w/Dust Cover 0.6 15.5 12.5 Round/Square Rectangular Ø 0.632"+0.007 (Ø 16.2+0.2) AL-C6V, Ø 5/8" (16mm), PCB Terminal: 0.012 x 0.059" (0.3 x 1.5) 1.303" (33.4) 0.098" (2.5) 0.117" (3) ❏0.936" (❏24) Ø 0.632"+0.007 (Ø 16.2+0.2) ❏0.936" (❏24) Ø 0.936" (Ø 24) Ø 1.17" (Ø 30) 0.195" (5) 0.195" (5) 0.234" (6) 0.148" 0.638" (16.2) (3.8) 0.234" 8 - Ø 0.062" (6) (Ø 1.6) Holes A2-28 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - A6 Series Dimensions con’t Marking Plates for Pushbuttons with Standard Size Lens Style Round—AL6M-W Square—AL6Q-W Rectangular—AL6H-W A2 OD2 Øa Ø OD ❏a Marking Area Marking Area OD1 a1 a2 Switches & Pilot Devices ❏OD Dimensions Marking Area Ø 5/8" (16mm) Outside (OD) Ø 0.538" (13.8mm) ❏0.538" (13.8mm) 0.538" x 0.772" (13.8 x 19.8mm) Marking Area (a) Ø 0.468" (12mm) ❏0.468" (12mm) 0.468" x 0.702" (12 x 18mm) Engraving must be made on the engraving area within 0.02" (0.5mm) deep. Marking Plates for Pushbutton with Oversize Lens Style Round—AL6M-MW Øa Square/Rectangular—AL6Q-QW Ø OD ❏OD ❏a Dimensions Marking Area Marking Area Outside (OD) Ø 0.491" (12.6mm) ❏0.491" (12.6mm) Marking Area (a) Ø 0.429" (11mm) ❏0.429" (11mm) Replacing Lens and Marking Plate Removal Remove the lens holder assembly (lens, marking plate and holder) from the operator by holding the color lens recesses with the lens removal tool (Part No.MT-101) and pulling out. Remove marking plate by pushing the color lens from the rear to disengage the latches. Marking plate must be engraved on the side as shown in the figure on the right. Ø 5/8" (16mm) Latches Recess Installation For illuminated and non-illuminated pushbuttons: 1. Insert marking plate inside lens in correct direction (For non-illuminated, install marking plate when replacing button). 2. Press color lens on to lens holder to engage latches. 3. Insert lens holder into housing in correct direction. Color Lens Engraving Area Marking Plate Lens Holder Operator Do not loosen spring on illuminated pushbutton units (except on pilot light units). The marking plate must be engraved on the front side as shown above. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-29 Miniature Switches & Pilot Devices ø16mm - L6 Series L6 Series — Miniature Switches and Pilot Devices Registration No. R9551089 (E-stops) Registration No. J9551458 (all other switches) Registration No. J9650511 (Pilot Lights) Conforming to Standards Operating Temperature Vibration Resistance Mechanical Life Degree of Protection IP65 (conforming to IEC 60529) Dielectric Strength Contact Ratings EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 N0.14 Operation: –25 to +55°C (without freezing), 45 to 85% rh Storage: -30 to +80°C (without freezing) 5 to 55Hz, 1.0 peak-peak amplitude max Operating limit: 100 m/sec2 (approximately 10G) Damage limit: 1000 m/sec2 (approximately 100G) Momentary pushbuttons 2,000,000 operations minimum All others: 250,000 operations minimum Shock Resistance Insulation Resistance Rated Insulation Voltage Rated Thermal Current Contact Resistance Rated Operating Current Switch unit: between live and ground: 2500 volt AC, 1 minute between terminals of different poles: 2500 volt AC, 1 minute between terminals of same pole: 1000 volt AC, 1 minute Illumination unit: between live part and ground: 2500 volt AC, 1 minute 100 MΩ minimum (using 500V DC megger) 250 V AC/DC Gold Contacts (pcb): 3A Silver Contacts (solder): 5A 50 Ω maximum initial value Silver Contacts Gold Clad Contacts (Solder Terminals) (PCB terminals) 30V 125V 250V 30V 125V AC resistive 3A 2A AC inductive 0.1A AC inductive 2A 1.5A DC resistive 0.1A DC resistive DC inductive Lamp Ratings Minimum Recommended Load (reference value for silver contacts) Terminal Style Contact Form Contact Material Electrical Life (at full load) Buzzer Ratings Switches & Pilot Devices A2 Key features of the 5/8” L6 Series include: • 5/8” (16mm) mounting holes • Locking lever removable contact blocks • Solder terminal or PCB terminal options • Available assembled or as sub-components • Worldwide approvals • Incandescent or LED illumination • Snap action contacts CSA Certified UL Recognized File No. LR21451 File No. E55996 Lamp Current Draw 2A 1A 0.4A 0.2A - 5 VAC/DC, 1mA 0.110” Solder Tab /PCB Snap Action, Double Throw Solder Tab: Pure Silver /PCB thermal Gold Plated Silver Momentary pushbuttons: 100,000 operations minimum (1800 operations / hour) All others: 100,000 operations minimum (1200 operations / hour) 5V DC LED: 8mA 6V LED: 7mA 6V incandescent: 100 mA 12V LED: 8mA 12V incandescent: 50 mA 24V LED: 8mA 24V incandescent: 25 mA Lamp Life Incandescent: 2000 hours./LED: 50,000 hours. (on pure DC, half-life intensity) Frequency Amplitude Operating Voltage Adjustable Cycle 2 khz ± 500 HZ 80db @ 0.1m (at rated voltage) 6V AC/DC or 12 - 24V AC/DC ± 10% 55 to 600 cycles per minute DC: 7mA AC: 20mA 1000 hrs. minimum 60V AC/DC -20 to 55 C (no freezing), 45 to 85% rh Current Draw Life Insulation Voltage Operating Temperature A2-30 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Style Operation Contact Momentary SPDT DPDT LA1B-M1C5-➀ LA1B-M1C6-➀ Round Square LA1B-A1C1V-➀ LA1B-A1C2V-➀ SPDT DPDT LA2B-M1C5-➀ LA2B-M1C6-➀ LA2B-M1C1V-➀ LA2B-M1C2V-➀ Maintained SPDT DPDT LA2B-A1C5-➀ LA2B-A1C6-➀ LA2B-A1C1V-➀ LA2B-A1C2V-➀ Momentary SPDT DPDT LA3B-M1C5-➀ LA3B-M1C6-➀ LA3B-M1C1V-➀ LA3B-M1C2V-➀ Maintained SPDT DPDT LA3B-A1C5-➀ LA3B-A1C6-➀ LA3B-A1C1V-➀ LA3B-A1C2V-➀ Momentary SPDT DPDT HA1B-M1C5-➀ HA1B-M1C6-➀ HA1B-M1C1V-➀ HA1B-M1C2V-➀ Maintained SPDT DPDT HA1B-A1C5-➀ HA1B-A1C6-➀ HA1B-A1C1V-➀ HA1B-A1C2V-➀ Momentary SPDT DPDT HA1B-M2C5-➀ HA1B-M2C6-➀ HA1B-M2C1V-➀ HA1B-M2C2V-➀ Maintained SPDT DPDT HA1B-A2C5-➀ HA1B-A2C6-➀ HA1B-A2C1V-➀ HA1B-A2C2V-➀ Momentary SPDT DPDT HA2B-M1C5-➀ HA2B-M1C6-➀ HA2B-M1C1V-➀ HA2B-M1C2V-➀ Maintained SPDT DPDT HA2B-A1C5-➀ HA2B-A1C6-➀ HA2B-A1C1V-➀ HA2B-A1C2V-➀ Momentary SPDT DPDT HA2B-M2C5-➀ HA2B-M2C6-➀ HA2B-M2C1V-➀ HA2B-M2C2V-➀ Maintained SPDT DPDT HA2B-A2C5-➀ HA2B-A2C6-➀ HA2B-A2C1V-➀ HA2B-A2C2V-➀ Momentary SPDT DPDT HA1B-M3C5-➀ HA1B-M3C6-➀ HA1B-M3C1V-➀ HA1B-M3C2V-➀ Maintained SPDT DPDT HA1B-A3C5-➀ HA1B-A3C6-➀ HA1B-A3C1V-➀ HA1B-A3C2V-➀ Oversize Round Flush Oversize Square Extended LA1B-A1C5-➀ LA1B-A1C6-➀ Momentary Rectangular Oversize Square Flush SPDT DPDT LA1B-M1C1V-➀ LA1B-M1C2V-➀ Mushroom Color Code Black B Green G Red R Blue S White W Yellow Y A2 Switches & Pilot Devices Maintained Oversize Round Extended Button Color Codes Terminal Style Solder Tab PCB 1. In place of ➀ specify Button Color Code from table on right. 2. Illuminated (translucent) style lenses also available, specify as such: instead of LA1B-M1C5-➀ use LA1B-M1C5L-➁ in place of ➁ specify Lens Color Code from next page.) 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1B-M1C1V-➀ becomes LA1B-M1C5V-➀. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-31 Miniature Switches & Pilot Devices ø16mm - L6 Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact + Safety Lever Lock + Operator + Button = Complete Part Part Numbers: Operators Part Numbers: Buttons/Lenses Style Style Button Appearance Round Round LA1L-MO AB6M-BK2-① LA1L-AO Square Terminal Style Contacts Solder PCB Tab Lens AL6M-LK2-➁ Gold Momentary Maintained Part Numbers: Contacts SPDT DPDT HA-C1 HA-C2 HA-C1V HA-C2V Silver Switches & Pilot Devices A2 SPDT DPDT HA-C5 HA-C6 HA-C5V HA-C6V Square LA2L-MO AB6Q-BK2-① LA2L-AO Rectangular AL6Q-LK2-➁ Rectangular LA3L-MO AB6H-BK2-① LA3L-AO AL6H-LK2-➁ Part Number: Safety Lever Lock Appearance Oversize Round Part Number Oversize Round Flush HA1B-MO HA1B-AO Oversize Square HA1A-B1-① HA1A-L1-➁* HA1A-B2-① – Oversize Round Extended HA2B-MO HA2B-AO Mushroom ① Button Color Code Oversize Square Flush HA1B-MOL HA2A-B1-① HA1B-A0L HA9Z-LS HA2A-L1-➁** Color Code Black B Green G Red R Blue S White W Yellow Y Oversize Square Extended HA2A-B2-① 1. In place of ① specify Button Color Code from table on right. 2. In place of ➁ specify Lens Color Code from table on right. 3. *requires HA1L-M0 or HA1L-A0 operator instead of HA1B-M0 or HA1B-A0. 4. **requires HA2L-M0 or HA2L-A0 instead of HA2B-M0 or HA2B-A0. A2-32 www.idec.com – Mushroom HA1A-B3-① HA1A-L3-➁ ➁ Lens Color Code Color Code Amber A Green G Red R Blue S Yellow Y White W USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series HA1B/HA1E E-Stop Miniature Switches and Pilot Devices: 5/8"(16mm) Key features of HA1B/HA1E Push lock Turn Reset include: • PCB or Solder Terminals • Quick Release Contact Blocks • Positive Action Contacts • 1 or 2 form B (SPST-NC) Contacts • IP65 Protection • 16mm Mounting Hole • Tamper Proof Construction 120VAC/3A Part Numbers: Nameplates HAAV–Yellow Plastic Contact Form 1 or 2 form B (2-SPST-NC) Termination PCB or Solder Terminal Contact Material Silver Applicable Standards EN60947-5-1, UL-508, CSA 22.2. No. 14 Rated Insulation Voltage 250V Degree of Protection IP65, when mounted in an enclosure Conditional Short-Circuit Current &Short-Circuit Protective Device 50 A (at 250V) 10A 250V Fuse, operation class aM according to IEC269-1 and IEC269-2 Positive opening travel 3.4mm Minimum force required to achieve positive opening operation of all break contacts. 10.3 N (2 form B contacts) Maximum travel including travel beyond the minimum travel position 5.5mm Maximum frequency of actuation 1,200 operations/hour Pollution Degree Ø 60mm ERGENCY EM STOP Part Number Blank HAAV-0 Engraved Emergency Stop HAAV-27 3 Part Numbers: Positive Action E-Stop Terminal Style Appearance Operation Contact Solder Tab DPST(NC) (2 form B) Pushlock/ Turn Reset E-Stop Short Body PCB HA1B-V2E2R SPST-NC (1 form B) DPST-NC (2 form B) HA1E-V2S1R HA1E-V2S2R HA1B-V2E2VR Button is nonremovable, available in red and as complete assembled unit only. – Part Number: Buzzers (IP40) Appearance Operating Voltage Terminal Style Solder/Tab PCB 6V AC/DC ± 10% LA3Z-1X2 LA3Z-1X2V 12V to 24 AC/DC ± 10% LA3Z-1X4 LA3Z-1X4V Buzzer-Rectangular www.idec.com Frequency: 2khz ± 500 hz Amplitude: 80db at 0.1m Beeping: Adjustable from steady tone to 600 beeps per minute. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-33 Switches & Pilot Devices 24VDC/2A Contact Ratings Positive Opening Operation Direct Opening Action UL Recognized File No. E55996 CSA approved File No. LR21451 File No. DK95-00138 Specifications A2 Miniature Switches & Pilot Devices ø16mm - L6 Series Pilot Lights (Assembled) ➁ Lens/LED Color Codes Color Code Part Numbers: Pilot Lights (LED) Switches & Pilot Devices A2 Style Voltage Solder Tab Terminal Style PCB Round 24V AC/DC LED 24VAC/DC Incandescent LA1P-1C04-➁ LA1P-1C07-➁ LA1P-1C04V-➁ LA1P-1C07V-➁ Amber A Green G Red R Blue S Yellow Y White W Square 24V AC/DC LED 24V AC/DC Incandescent LA2P-1C04-➁ LA2P-1C07- ➁ LA2P-1C04V-➁ LAZP-1C07V-➁ Rectangle 24V AC/DC LED 24V AC/DC Incandescent LA3P-1C04-➁ LA3P-1C07-➁ LA3P-1C04V-➁ LA3P-1C07V-➁ Oversize Round 24V AC/DC LED 24V AC/DC Incandescent HA1P-1C04-➁ HA1P-1C07-➁ HA1P-1C04V-➁ HA1P-1C07V-➁ 24V AC/DC LED 24V AC/DC Incandescent HA2P-1C04-➁ HA2P-1C07-➁ HA2P-1C04V-➁ HA2P-1C07V-➁ 24V AC/DC LED 24V AC/DC Incandescent HA1P-14-➁ HA1P-17-➁ – 24V AC/DC LED 24V AC/DC Incandescent HA2P-14-➁ HA2P-17-➁ – Voltage/Lamp Code Voltage Code 5V DC LED 1 6V AC/DC LED 2 12V AC/DC LED 3 24V AC/DC LED 4 120 V AC LED 8 6V AC/DC Incandescent 5 12V AC/DC Incandescent 6 24V AC/DC Incandescent 7 Oversize Square Oversize Round Unibody Oversize Square Unibody 1. In place of ➁ specify Lens/LED Color Code from table. 2. Lamps also available in 5VDC, 6V AC/DC, 12V AC/DC or 120V AC, change “4” or “7” using Voltage/Lamp Codes (ie LA1P-1C03-➁ uses 12V AC/DC LED). A2-34 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Pilot Lights (Sub-Assembled) Terminals + Safety Lever Lock + Lamp Holder + Lamp + Operator + Lens = Completed Unit A2 Style Part Number Part Numbers: Lenses Style Part Number Round Round Part Numbers: Lamps Style Voltage LED Square Incandescent Square 6V AC/DC 12V AC/DC 24V AC/DC AL6Q-LK3-➁ LA2P-0 AL6H-LK3-➁ LA3P-0 LH-06 LH-14 LH-28 In place of ➁ specify LED color code from table below. Rectangular Rectangular 5V DC 6V AC/DC 12V AC/DC 24V AC/DC 120 V AC AL6M-LK3-➁ LA1P-0 Part Number LFTD-5➁ LFTD-6➁ LFTD-1➁ LFTD-2➁ LFTD-H2➁ Part Numbers: Terminals Solder Tab Appearance PCB Oversize Round Oversize Round HA-C00 Not required for unibody models. Oversize Square Oversize Square HA2A-P1-➁ HA2P-0 Part Number: Lamp Holder Appearance Oversize Round Unibody HA1P-00 In place of ➁ specify lens color S t code. y l e Part Number Part Number HA9Z-AH Part Number: Safety Lever Lock Appearance Part Number HA9Z- LS Oversize Square Unibody HA2P-00 ➁ Lens/LED Color Codes Color Code Amber Green Red Blue Yellow www.idec.com HA-C00V HA1A-P1-➁ HA1P-0 A G R S Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-35 Switches & Pilot Devices Part Numbers: Operators Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons Style A2 Operation Round Switches & Pilot Devices Momentary Maintained Square Momentary Maintained Rectangular Momentary Maintained Oversize Round Momentary Maintained Oversize Square Momentary Maintained Mushroom Momentary Maintained Lamp Voltage Contact 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT 24V AC/DC LED SPDT DPDT 24V AC/DC Incandescent SPDT DPDT Terminal Style Solder Tab PCB LA1L-M1C14V-➁ LA1L-M1C54-➁ LA1L-M1C64-➁ LA1L-M1C24V-➁ LA1L-M1C17V-➁ LA1L-M1C57-➁ LA1L-M1C67-➁ LA1L-M1C27V-➁ LA1L-A1C14V-➁ LA1L-A1C54-➁ LA1L-A1C64-➁ LA1L-A1C24V-➁ LA1L-A1C17V-➁ LA1L-A1C57-➁ LA1L-A1C67-➁ LA1L-A1C27V-➁ LA2L-M1C14V-➁ LA2L-M1C54-➁ LA2L-M1C64-➁ LA2L-M1C24V-➁ LA2L-M1C17V-➁ LA2L-M1C57-➁ LA2L-M1C67-➁ LA2L-M1C27V-➁ LA2L-A1C14V-➁ LA2L-A1C54-➁ LA2L-A1C64-➁ LA2L-A1C24V-➁ LA2L-A1C17V-➁ LA2L-A1C57-➁ LA2L-A1C67-➁ LA2L-A1C27V-➁ LA3L-M1C14V-➁ LA3L-M1C54-➁ LA3L-M1C64-➁ LA3L-M1C24V-➁ LA3L-M1C17V-➁ LA3L-M1C57-➁ LA3L-M1C67-➁ LA3L-M1C27V-➁ LA3L-A1C14V-➁ LA3L-A1C54-➁ LA3L-A1C64-➁ LA3L-A1C24V-➁ LA3L-A1C17V-➁ LA3L-A1C57-➁ LA3L-A1C67-➁ LA3L-A1C27V-➁ HA1L-M1C14V-➁ HA1L-M1C54-➁ HA1L-M1C64-➁ HA1L-M1C24V-➁ HA1L-M1C17V-➁ HA1L-M1C57-➁ HA1L-M1C67-➁ HA1L-M1C27V-➁ HA1L-A1C14V-➁ HA1L-A1C54-➁ HA1L-A1C64-➁ HA1L-A1C24V-➁ HA1L-A1C17V-➁ HA1L-A1C57-➁ HA1L-A1C67-➁ HA1L-A1C27V-➁ HA2L-M1C14V-➁ HA2L-M1C54-➁ HA2L-M1C64-➁ HA2L-M1C24V-➁ HA2L-M1C17V-➁ HA2L-M1C57-➁ HA2L-M1C67-➁ HA2L-M1C27V-➁ HA2L-A1C14V-➁ HA2L-A1C54-➁ HA2L-A1C64-➁ HA2L-A1C24V-➁ HA2L-A1C17V-➁ HA2L-A1C57-➁ HA2L-A1C67-➁ HA2L-A1C27V-➁ HA1L-M3C14V-➁ HA1L-M3C54-➁ HA1L-M3C64-➁ HA1L-M3C24V-➁ HA1L-M3C17V-➁ HA1L-M3C57-➁ HA1L-M3C67-➁ HA1L-M3C27V-➁ HA1L-A3C14V-➁ HA1L-A3C54-➁ HA1L-A3C64-➁ HA1L-A3C24V-➁ HA1L-A3C17V-➁ HA1L-A3C57-➁ HA1L-A3C67-➁ HA1L-A3C27V-➁ ➁ Lens Color Codes Color Code Amber A Green G Red R Blue S Yellow Y White W Voltage/Lamp Code Voltage Code 5V DC LED 1 6V AC/DC LED 2 12V AC/DC LED 3 24V AC/DC LED 4 120V AC LED 8 6V AC/DC Incandescent 5 12V AC/DC Incandescent 6 24V AC/DC Incandescent 7 1. In place of➁ specify lens color code from table at right. 2. Lamps also available in 5V DC, 6V AC/DC, 12 V AC/DC or 120V AC, change “4” or “7” using voltage/lamp codes (ie LA1P-1C03-➁ uses 12V AC/DC LED). 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1L-M1C14V-➀ becomes LA1L-M1C54V-➀. A2-36 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Pushbuttons (Sub-Assembled) Contacts + Safety Lever Lock + Lamp Holder + Lamp + Operator + Lens = Completed Unit A2 Style Momentary Maintained Part Numbers: Lenses Style Part Number Round Round LA1L-MO Part Numbers: Lamps Appearance Voltage Part Number LED 5V DC 6V AC/DC 12V AC/DC 24V AC/DC 120V AC LFTD-5➁ LFTD-6➁ LFTD-1➁ LFTD-2➁ LFTD-H2➁ 6V AC/DC 12V AC/DC 24V AC/DC LH-06 LH-14 LH-28 AL6M-LK2-➁ LA1L-AO Incandescent Square Square LA2L-MO In place of ➁ specify LED color code from table below. AL6Q-LK2-➁ LA2L-AO Switches & Pilot Devices Part Numbers: Operators Part Numbers: Contacts Solder Tab PCB Gold LA3L-MO Contacts SPDT DPDT HA-C10 HA-C20 HA-C10V HA-C20V Silver Terminal Style Rectangular Appearance Rectangular SPDT DPDT HA-C50 HA-C60 HA-C50V HA-C60V AL6H-LK2-➁ LA3L-AO Oversize Round Oversize Round HA1L-MO HA1A-L1-➁ HA1L-A0 Oversize Square Oversize Square HA2L-MO Part Number:Lamp Holder HA2A-L1-➁ HA2L-AO Appearance Part Number HA9Z-AH Mushroom Mushroom Part Number: Safety Lever Lock HA1B-MOL HA1B-AOL HA1A-L3-➁ Appearance Part Number HA9Z-LS In place of ➁ specify Lens Color Code from table. ➁ Lens/LED Color Codes Color Code Amber Green Red Blue Yellow White www.idec.com A G R S Y W USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-37 Miniature Switches & Pilot Devices ø16mm - L6 Series Selector Switches (Assembled) Part Numbers: Selector Switches Round Maintained L R Contact DPDT LA1S-2C6 Contact Operations (for all selectors) Contacts Operator Position and Contact Operation LA1S-2C2V Left Left Spring return from right L R DPDT LA1S-21C6 LA1S-21C2V 2-pos. (DPDT) Maintained C L R DPDT LA1S-3C6 NO Right NC NO NO Right NO NC Right 45˚ 3-Position Left Spring return from right L R C DPDT DPDT LA1S-31C6 LA1S-32C6 LA1S-31C2V LA1S-32C2V Spring return from left L 2-Way spring return L R DPDT LA1S-33C6 LA1S-33C2V L R DPDT LA2S-2C6 LA2S-2C2V Spring return from right L R DPDT LA2S-21C6 LA2S-21C2V Maintained L R DPDT LA2S-3C6 LA2S-3C2V R DPDT LA2S-31C6 LA2S-31C2V R DPDT LA2S-32C6 LA2S-32C2V R 3-pos. (DPDT) NO NC NO Left Center NO NC Oversize Round 90˚ 2-Position 90˚ 2-Position 45˚ 3-Position Rectangular 90˚ 2-Position 45˚ 3-Position Square A2-38 Maintained Spring return from right C C L C Spring return from left L 2-Way spring Return L R DPDT LA2S-33C6 LA2S-33C2V L R DPDT LA3S-2C6 LA3S-2C2V Spring return from right L R DPDT LA3S-21C6 LA3S-21C2V Maintained L R DPDT LA3S-3C6 LA3S-3C2V R DPDT LA3S-31C6 LA3S-31C2V R DPDT LA3S-32C6 LA3S-32C2V Maintained Spring return from right C C C L C Spring return from left L 2-Way spring Return L R DPDT LA3S-33C6 LA3S-33C2V L R DPDT HA1S-2C6 HA1S-2C2V Spring return from right L R DPDT HA1S-21C6 HA1S-21C2V Maintained L R DPDT HA1S-3C6 HA1S-3C2V R DPDT HA1S-31C6 HA1S-31C2V R DPDT HA1S-32C6 HA1S-32C2V R DPDT HA1S-33C6 HA1S-33C2V Maintained Spring return from right C C C L C Spring return from left L 2-Way spring Return L www.idec.com C Right NO NC Right NO Left C NC LA1S-3C2V Left C NC Left Right 45˚ 3-Position Switches & Pilot Devices A2 Position 90˚ 2 -Position Style Terminal Style Solder Tab PCB NC NC Right NO NC As viewed from front of switch. 1. All assembled selector switches use DPDT contacts. 2. For SPDT contacts see sub-components on next page. 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1S-21C2V becomes LA1S-21C6V. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Selector Switches (Sub-Assembled) Contacts + Safety Lever Lock + Operator = Complete Part A2 Switches & Pilot Devices Part Numbers: Operators Style Position Round Square Rectangular Oversize Round Function Part Number 2 Maintained Spring from right LA1S-2Y LA1S-21Y 3 Maintained Spring from right Spring from left Spring from both LA1S-3Y LA1S-31Y LA1S-32Y LA1S-33Y 2 Maintained Spring from right LA2S-2Y LA2S-21Y 3 Maintained Spring from right Spring from left Spring from both LA2S-3Y LA2S-31Y LA2S-32Y LA2S-33Y 2 Maintained Spring from right LA3S-2Y LA3S-21Y 3 Maintained Spring from right Spring from left Spring from both LA3S-3Y LA3S-31Y LA3S-32Y LA3S-33Y 2 Maintained Spring from right HA1S-2Y HA1S-21Y 3 Maintained Spring from right Spring from left Spring from both HA1S-3Y HA1S-31Y HA1S-32Y HA1S-33Y Part Numbers: Contacts Contacts Silver Gold Appearance Terminal Style Solder Tab PCB SPDT DPDT HA-C1 HA-C2 HA-C1V HA-C2V SPDT DPDT HA-C5 HA-C6 HA-C5V HA-C6V 1. All assembled switches listed on previous page use DPDT contacts. 2. SPDT Contacts for use on 2 position selector switch only Part Number: Safety Lever Lock Appearance Part Number HA9Z-LS www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-39 Miniature Switches & Pilot Devices ø16mm - L6 Series Key Switches (Assembled) Part Numbers: Key Switches Style 90 2-Position Maintained Spring return from right L R L R Contacts DPDT LA1K-2C6➂ DPDT C Maintained L R DPDT LA1K-21C6B LA1K-3C6➂ Contact Operations (for all selectors) Contacts LA1K-2C2V➂ LA1K-21C2VB Operator Position and Contact Operation Left Left 2-pos. (DPDT) NO NC Right NO NO Left NO NC 45 ˚3-Position Spring return from right Spring return from left Square 90˚ 2-Position 2-Way spring return Maintained Spring return from right C L R DPDT NO R DPDT 45 ˚3-Position 90 ˚2-Position Rectangular Spring return from right Right R DPDT LA1K-33C6D LA1K-33C2VD L R DPDT LA2K-2C6➂ LA2K-2C2V➂ L R DPDT LA2K-21C6B LA2K-21C2VB R DPDT LA2K-3C6➂ LA2K-3C2V➂ L C L L R DPDT C 45 ˚3-Position 90 ˚2-Position LA2K-31C2V➂ R DPDT LA2K-32C6➂ LA2K-32C2V➂ R DPDT LA2K-33C6D LA2K-33C2VD NC Right NO NO NC NC Right NO NC ➂ Key Retention Option Codes Code Description A B C E G C H L R DPDT LA3K-2C6➂ LA3K-2C2V➂ L R DPDT LA3K-21C6B LA3K-21C2VB R DPDT LA3K-3C6➂ LA3K-3C2V➂ R DPDT LA3K-31C6➂ LA3K-31C2V➂ R DPDT LA3K-32C6➂ LA3K-32C2V➂ L Spring return from right L Spring return from left L 2-Way spring return L R DPDT LA3K-33C6D LA3K-33C2VD L R DPDT HA1K-2C6➂ HA1K-2C2V➂ L R DPDT HA1K-21C6B HA1K-21C2VB R DPDT HA1K-3C6➂ HA1K-3C2V➂ R DPDT HA1K-31C6➂ HA1K-31C2V➂ R DPDT HA1K-32C6➂ HA1K-32C2V➂ R DPDT HA1K-33C6D HA1K-33C2VD C C Key not retained in any position (removable in all positions) Key retained in right position only Key retained in left position only Key retained in left and right (3 position only) Key retained in center only (3 position only) Key retained right and center (3 position only) Key retained left and center (3 position only) Key cannot be removed from a spring-return position. C C A2-40 LA2K-31C6➂ Maintained Spring return from right NO As viewed from front of switch. D 2-Way spring return Maintained NC C C Oversize Round Left Center LA1K-32C2V➂ L L Spring return from right NO Left Spring return from left Maintained NC LA1K-31C2V➂ Right C Maintained LA1K-32C6➂ NC LA1K-3C2V➂ 3-pos. (DPDT) C L LA1K-31C6➂ NC Right Left Right Left 45 ˚3-Position Switches & Pilot Devices A2 Round Operation Terminal Type Solder Tab PCB Maintained L Spring return from right L Spring return from left L 2-Way spring return L C C 1. In place of ➂ specify Key Retention Code from next page. 2. All assembled key switches have DPDT contacts. For SPDT see subassembled on next page. 3. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1K-2C2V➂ becomes LA1K-2C6V➂. C www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Key Switches (Sub-Assembled) Contacts + Safety lever lock + Operator = Complete Part A2 Square Operation Part Number 2 Maintained Spring from right LA1K-2➂ LA1K-21B 3 Maintained Spring from right Spring from left Spring from both LA1K-3➂ LA1K-31➂ LA1K-32➂ LA1K-33D 2 Maintained Spring from right LA2K-2➂ LA2K-21B 3 Maintained Spring from right Spring from left Spring from both LA2K-3➂ LA2K-31➂ LA2K-32➂ LA2K-33D Terminal Style Contacts Solder PCB Tab Appearance Gold Round Positions SPDT DPDT HA-C1 HA-C2 HA-C1V HA-C2V Silver Style Part Numbers: Contacts SPDT DPDT HA-C5 HA-C6 HA-C5V HA-C6V 1. All assembled selectors listed on previous page use DPDT contacts. 2. SPDT contacts are for use on 2 position key switches only. Part Number: Safety Lever Lock Appearance Rectangular 2 Maintained Spring from right Part Number LA3K-2➂ LA3K-21B HA9Z-LS 3 Oversize Round 2 3 Maintained Spring from right Spring from left Spring from both Maintained Spring from right Maintained Spring from right Spring from left Spring from both LA3K-3➂ LA3K-31➂ LA3K-32➂ LA3K-33D ➂ Key Retention Option Codes Code Description HA1K-2➂ HA1K-21B A HA1K-3➂ HA1K-31➂ HA1K-32➂ HA1K-33D B C D E G H 1. In place of ➂ specify key removable code from table on right. Key not retained in any position (removable in all positions) Key retained in right position only Key retained in left position only Key retained in left and right (3 position only) Key retained in center only (3 position only) Key retained right and center (3 position only) Key retained left and center (3 position only) Key cannot be removed from a spring-return position. 2. Operator includes two keys. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-41 Switches & Pilot Devices Part Numbers: Operators Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Selector Switches Part Numbers: Illuminated Selectors Switches A2 Round Maintained Spring return from right Contact Voltage L R L DPDT Maintained L 24V LED 24V Incand. DPDT 24V LED 24V Incand. LA1F-21C64-➁ LA1F-21C24V-➁ LA1F-21C67-➁ LA1F-21C27V-➁ DPDT 24V LED 24V Incand. LA1F-3C64-➁ LA1F-3C67-➁ R DPDT 24V LED 24V Incand. LA1F-31C64-➁ LA1F-31C24V-➁ LA1F-31C67-➁ LA1F-31C27V-➁ R DPDT 24V LED 24V Incand. LA1F-32C64-➁ LA1F-32C24V-➁ LA1F-32C67-➁ LA1F-32C27V-➁ R C R Contact Operations (for all selectors) Operator Position and Contact Operation Contacts Left Left 2-pos. (DPDT) LA1F-3C24V-➁ LA1F-3C27V-➁ NO NC Right NO NO Left NO NC 45˚ 3-Position Spring return from right L Spring return from left L NO C Maintained Spring return from right C L R DPDT 24V LED 24V Incand. LA1F-33C64-➁ LA1F-33C24V-➁ LA1F-33C67-➁ LA1F-33C27V-➁ L R DPDT 24V LED 24V Incand. LA2F-2C64-➁ LA2F-2C67-➁ L R DPDT 24V LED 24V Incand. LA2F-21C64-➁ LA2F-21C24V-➁ LA2F-21C67-➁ LA2F-21C27V-➁ R DPDT 24V LED 24V Incand. LA2F-3C64-➁ LA2F-3C67-➁ R DPDT 24V LED 24V Incand. LA2F-31C64-➁ LA2F-31C24V-➁ LA2F-31C67-➁ LA2F-31C27V-➁ R DPDT 24V LED 24V Incand. LA2F-32C64-➁ LA2F-32C24V-➁ LA2F-32C67-➁ LA2F-32C27V-➁ Square 90˚ 2-Position 45˚ 3-Position C Rectangular 45˚ 3-Position 90˚ 2-Position NC Right LA2F-2C24V-➁ LA2F-2C27V-➁ LA2F-3C24V-➁ LA2F-3C27V-➁ Right NO Right NO NC Spring return from left L 2-Way spring return L R DPDT 24V LED 24V Incand. LA2F-33C64-➁ LA2F-33C24V-➁ LA2F-33C67-➁ LA2F-33C27V-➁ L R DPDT 24V LED 24V Incand. LA3F-2C64-➁ LA3F-2C67-➁ 5V DC LED 1 DPDT 24V LED 24V Incand. LA3F-21C64-➁ LA3F-21C24V-➁ LA3F-21C67-➁ LA3F-21C27V-➁ 6V AC/DC LED 2 12V AC/DC LED 3 R DPDT 24V LED 24V Incand. LA3F-3C64-➁ LA3F-3C67-➁ 24V AC/DC LED 4 R DPDT 24V LED 24V Incand. LA3F-31C64-➁ LA3F-31C24V-➁ LA3F-31C67-➁ LA3F-31C27V-➁ R DPDT 24V LED 24V Incand. LA3F-32C64-➁ LA3F-32C24V-➁ LA3F-32C67-➁ LA3F-32C27V-➁ Maintained Spring return from right C L R LA3F-2C24V-➁ LA3F-2C27V-➁ LA3F-3C24V-➁ LA3F-3C27V-➁ Maintained L Spring return from right L Spring return from left L 2-Way spring return L R DPDT 24V LED 24V Incand. LA3F-33C64-➁ LA3F-33C24V-➁ LA3F-33C67-➁ LA3F-33C27V-➁ L R DPDT 24V LED 24V Incand. HA1F-2C64-➁ HA1F-2C67-➁ L R DPDT 24V LED 24V Incand. HA1F-21C64-➁ HA1F-21C24V-➁ HA1F-21C67-➁ HA1F-21C27V-➁ R DPDT 24V LED 24V Incand. HA1F-3C64-➁ HA1F-3C67-➁ R DPDT 24V LED 24V Incand. HA1F-31C64-➁ HA1F-31C24V-➁ HA1F-31C67-➁ HA1F-31C27V-➁ R DPDT 24V LED 24V Incand. HA1F-32C64-➁ HA1F-32C24V-➁ HA1F-32C67-➁ HA1F-32C27V-➁ DPDT 24V LED 24V Incand. HA1F-33C64-➁ HA1F-33C24V-➁ HA1F-33C67-➁ HA1F-33C27V-➁ Maintained Spring return from right C C C C Maintained L Spring return from right L Spring return from left L C C C L www.idec.com R HA1F-2C24V-➁ HA1F-2C27V-➁ HA1F-3C24V-➁ HA1F-3C27V-➁ NO NC ➁ Lens/LED Color Code Color Code L C NC As viewed from front of switch. Spring return from right C NC Right L 2-Way spring return A2-42 NO NC NO Left Center Maintained C Oversize Round 3-pos. (DPDT) NC Left 2-Way spring return 90˚ 2-Position C NC Right Left Right Left 45˚ 3-Position Switches & Pilot Devices Operation 90˚ 2-Position Style Terminal Style Solder Tab PCB LA1F-2C64-➁ LA1F-2C24V-➁ LA1F-2C67-➁ LA1F-2C27V- ➁ Amber Green Red Blue Yellow White A G R S Y W Voltage/Lamp Code Voltage Code 120V AC LED 8 6V AC/DC Incandescent 5 12V AC/DC Incandescent 6 24V AC/DC Incandescent 7 1. In place of ➁ specify Lens/LED Color Code from table above. 2. Lamps also available in 5V DC, 6V AC/DC or 12 V AC/DC, change “4” or “7” using voltage/lamp codes (ie LA1F-2C63-➁ uses 12V AC/DC LED). 3. All switches listed have DPDT contacts. For SPDT see sub-assembled on next page. 4. PCB terminal models also avail- able with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1F-2C24V-➁ becomes LA1F-2C64V-➁. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Illuminated Selector Switches (Sub-Assembled) Contacts + Safety lever lock + Lamp Holder + Lamp + Operator + Lens/Handle = Completed Unit A2 Style Part Numbers: Lenses/Handles Positions Round Square Rectangular Oversize Round Function Part Number 2 Maintained Spring from right LA1F-20 LA1F-210 3 Maintained Spring from right Spring from left Spring from both LA1F-30 LA1F-310 LA1F-320 LA1F-330 2 Maintained Spring from right LA2F-20 LA2F-210 3 Maintained Spring from right Spring from left Spring from both LA2F-30 LA2F-310 LA2F-320 LA2F-330 2 Maintained Spring from right LA3F-20 LA3F-210 3 Maintained Spring from right Spring from left Spring from both LA3F-30 LA3F-310 LA3F-320 LA3F-330 2 Maintained Spring from right HA1F-20 HA1F-210 3 Maintained Spring from right Spring from left Spring from both HA1F-30 HA1F-310 HA1F-320 HA1F-330 Part Numbers: Contacts Appearance Gold SPDT DPDT HA-C1 HA-C2 HA-C10V HA-C20V Silver SPDT DPDT HA-C50 HA-C60 HA-C50V HA-C60V LA1A-F-➁ Oversize HA1A-F-➁ In place of ➁ specify Lens Color Code from table. Part Number: Safety Lever Lock Appearance A G R S Y W www.idec.com Part Number HA9Z-LS Appearance Part Number HA9Z-AH Part Numbers: Lamps Appearance 1. All assembled selectors on previous pages use DPDT contacts. SPDT contacts are for use only on two position selectors. Amber Green Red Blue Yellow White Part Number Standard Part Number: Lamp Holder Terminal Style Solder Contacts PCB Tab Appearance ➁ LED/Lens Color Code Color Code Switches & Pilot Devices Part Numbers: Operators LED Voltage 5V DC 6V AC/DC 12V AC/DC 24V AC/DC 120V AC Part Numbers LFTD-5➁ LFTD-6➁ LFTD-1➁ LFTD-2➁ LFTD-H2➁ Incandescent 6V AC/DC 12V AC/DC 24V AC/DC LH-06 LH-14 LH-28 In place of ➁ specify LED Color Code from table. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-43 Miniature Switches & Pilot Devices ø16mm - L6 Series Pushbutton Selectors (Assembled) Part Numbers: Pushbutton Selectors ① Button Color Code Terminal Style Style 2 Position PCB HA1R-2C6-① 3 Position HA1R-2C2V-① HA1R-3C6-① HA1R-3C2V-① Color Code Black B Green G Red R Blue S Yellow Y 1. In place of ① specify Button Color Code. 2. PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie HA1R-2C2V-① becomes HA1R-2C6V-①). Contact Operation Operator Position Style Left Normal 2 Position Left NO NO Center Depressed Left Right NC NO Left 3 Position NO NC NO NO NC NC Depressed Normal Right NO Left Right NC NC Normal Right Left – NC Right NO Left NC NO NC – NO Right NO NC NC Left Blocked NO NC Depressed Right NO NC Right NO NC Right Left NO NO NC Left NO NC NC Right NO NC Lever Switch (Assembled) Part Numbers: Lever Switches Style Operation Contacts Terminal Type Solder Tab PCB DPDT LA1T-2C6 LA1T-2C2V DPDT LA1T-21C6 LA1T-21C2V DPDT LA1T-22C6 LAIT-22C2V DPDT LA1T-3C6 LA1T-3C2V DPDT LA1T-31C6 LA1T-31C2V DPDT LA1T-32C6 LA1T-32C2V DPDT LA1T-33C6 LA1T-33C2V U Maintained 2-Position D U Spring return from top D U Spring Return from bottom D U Maintained C D U Spring return from top 3-Position Switches & Pilot Devices A2 Solder Tab C D U Spring return from bottom C PCB terminal models also available with silver contacts (change “1” or “2” to “5” or “6” respectively, ie LA1T-2C2V becomes LA1T-2C6V). D U Spring return from both C D Contact Operation Contacts Operator Position & Contact Operation 2-pos. Maintained (DPDT) Spring from Top 2-pos Spring Return (DPDT). from Bottom 3-pos. (DPDT) All models A2-44 Down Left NO NC Left NO Up Left NO NO NC NC NO NC NO Right NO NC NC Left Right NC Left NO Center Right Left NO NC www.idec.com Right NO NC NC Left NO NC Right NO NC Right NO NC Right NO NC As viewed from front of switch. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Accessories Part Specifications Part Number Notes Ring Wrench Made of metal MT-001 Used for tightening the plastic locking ring when installing the L6 series unit on a panel. Tightening torque should not exceed 9kgf cm when tightening a locking ring. Made of rubber. Used for removing and replacing LED and incandescent lamps in illuminated units. OR-44 Rubber tool used for replacing LED and incandescent lamps. Lens Removal Tool For Illuminated pushbuttons and pilot lights. MT-101 Used for removing the lens or button from the housing. LED Lamp 5V DC 6V AC/DC 12V AC/DC 24V AC/DC 120V AC LFTD-5➁ LFTD-6➁ LFTD-1➁ LFTD-2➁ LFTD-H2➁ T 1-3/4 miniature flange base. In place of ➁ specify LED Color Code (see page A2-43). Incandescent Lamp 6V AC/DC 12V AC/DC 24V AC/DC LH-06 LH-14 LH-28 0.5W, T 1-3/4 miniature flange base 90 degrees opening maintained Switch Guard Dust-proof Cover 180 degrees opening, spring return Round/Square AL-K6 Rectangular AL-KH6 Round/Square AL-K6SP Rectangular AL-KH6SP Oversize Round/Sq Terminal Cover AL-D6 For square units AL-DQ6 H6-VL2 Unibody Pilot Lights H6-PVL Made of white nylon Covers terminals to prevent possible electric shock. Rubber AL-B6 Aluminum AL-BM6 for LA1K (#132) AS6-SK for HA1K (#231) KG9Z-SK Replacement Keys Round Square Rectangle Oversize Round Oversize Square Mushroom All models AL6M-W AL6Q-W AL6H-W HA9Z-P1-W HA9Z-P2-W HA9Z-P13-W HA9Z-LN L6 standard AL6-LP L6 oversize HA9Z-LP Replacement Selector Inserts HA9Z-HC1-① Replacement Safety Lever Lock HA9Z-LS www.idec.com Fills unused panel cutouts. Made of nitrile rubber. Push-in installation from front of panel. IP65 (oiltight) rated. Fills unused panel cutouts. Made of aluminum. Screwon locking ring from inside of panel. IP65 (oiltight) rated. Pair of keys. Replacement Engraving Inserts Replacement Anti-Rotation Ring Provides extra level of sealing for “front-panel” portion of switches. (Not applicable for units with oversize lenses or buttons). AL-DH6 All removable contacts Mounting Hole Plug Replacement Locking Ring Prevents inadvertent switch operation. IP65 oiltight rated. HA9Z-K1 For round units For rectangular units Prevents inadvertent switch operation. IP40 dust-tight rated. Prevents rotation of switches in panel. (included with all assembled switches) Applicable to round oversize selectors only ① = (G, R, S, W, Y) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-45 Switches & Pilot Devices Lamp Holder Tool (Made of Rubber) A2 Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions Non -Illuminated Pushbuttons (LA*B) 0.11 (2.8) 0.24 (6.0) 0.71 (18.0) 0.71 (18.0) 0.27 (6.8) 0.35 (9.0) 1.39 (35.4) 0.71 (18.0) 0.38 (9.6) 0.98 (24.8) 0.94 (24.0) 0.71 (18.0) Emergency Stop Switch (HA1B) LOC " .61 ) RO m .5m (15 Switches & Pilot Devices A2 Rubber Washer K Panel Thickness 0.02"-0.24" (0.5~6.0mm) Stopper Locking Ring " 98 ) 0. m Ø .9m 4 (2 PCB Terminal 0.34" + (8.7mm) NC NC - 0.21" (5.4mm) ø0.70" ø0.83" (17.8mm) 0.20" 0.41" (5.2mm) (10.5mm) 0.43" (11mm) 0.62" (15.8mm) (21mm) 0.53" (13.5mm) 1.42" (36mm) 0.98" (25mm) Emergency Stop Switch (HA1E) - Short Body Style Buzzer (LA3Z) 0.11 (2.8) 0.71 (18.0) 0.24 (6.0) 1.39 (35.4) 0.35 (9.0) 0.62 (15.7) 0.35 (9.0) 0.98 (24.8) 0.94 (24.0) Pilot Lights (LA*P) 0.11 (2.8) 0.24 (6.0) 0.71 (18.0) 0.71 (18.0) 0.27 (6.8) A2-46 0.35 (9.0) 1.39 (35.4) www.idec.com 0.38 (9.6) 0.71 (18.0) 0.71 (18.0) 0.98 (24.8) 0.94 (24.0) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t Illuminated Pushbuttons (LA*L) 0.11 (2.8) A2 0.24 (6.0) 0.27 (6.8) 0.35 (9.0) 1.39 (35.4) 0.38 (9.6) 0.71 (18.0) Switches & Pilot Devices 0.71 (18.0) 0.71 (18.0) 0.98 (24.8) 0.94 (24.0) 0.71 (18.0) Key Switches (LA*K) 0.11 (2.8) 0.24 (6.0) 0.71 (18.0) 0.71 (18.0) 0.27 (6.8) 0.35 (9.0) 1.39 (35.4) .98 (24.9) 0.71 (18.0) 0.98 (24.8) 0.94 (24.0) 0.71 (18.0) Selector Switches (LA*S) 0.11 (2.8) 0.24 (6.0) 0.71 (18.0) 0.71 (18.0) 0.27 (6.8) Panel Cut-Out 0.35 (9.0) 1.39 (35.4) 0.66 (16.8) 0.71 (18.0) 0.94 (24.0) 0.71 (18.0) PCB Layout (except for Buzzer and E-Stop) 0.20 (5.0) PCB Pins Acess Hole for Locking Lever 0.36 (9.3) 0.20 (5.0) 0.98 (24.8) 0.03 (0.8) 0.24 (6.0) Ø0.05 (1.2) 0.42 (10.7) 0.04 (1.0) 0.27 (6.8) 0.20 (5.0) 0.06 (1.5) 0.25 (6.4) 0.94 (24.0) HA1B E-Stop PCB Mounting Pattern 0.21" (5.3mm) 0.21" (5.3mm) 0.21" (5.4mm) 0.34" (8.7mm) " 05 ) 0. m Ø .2m (1 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-47 Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t NC X1 X2 NO NO C C 1.02 [25.9] X2 0.94 [24.0] 0.43 [11.0] NO C NC NO NC Oversize Extended Non-Illuminated Pushbutton C 0.59 [15.1] Oversize Unibody PIlot Lights 1.48 [37.5] NC NC NO C NO Mushroom Pushbuttons 1.18 [30.0] ÿ1.18 [ÿ30.0] 0.79 [20.0] NO C NC NO NC Oversize Selector Switch C Switches & Pilot Devices A2 NC Oversize Flush Pushbutton and Pilot Lights 0.94 [23.8] ÿ0.94 [ÿ23.8] 0.77 [19.5] A2-48 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t NO C NC NO C NC Oversize Key Switch A2 Switches & Pilot Devices 1.54 [39.0] NC NC NO C NO Lever Switch 0.94 [23.8] Terminal Configurations .94 (24.) 1.30 (33) .41 (10.5) Steady Slow Quick Input Terminal (X1) Buzzer Sound Switch AL-K6SP .51 (13) 1.34 (34) .93 (23.5) X1 X1 AL-KH6SP .51 (13) X2 Input Terminal (X2) X2 NO NC Buzzer C NC NO X1 X2 X2 C C C X2 Lamp Terminal (–) Lamp Terminal (–) X2 Lamp Terminal (+) X1 NC Lamp Terminal (+) NO NC NO Illuminated Pushbuttons Pilot Lights Non Illuminated Pushbutton R2 Panel Thickness: .20 max. (5 max) .71 (18) .93 (23.5) 2 .41 (10.5) 1.79 (45.5) .98 (25) 1.79 (45.5) .75 (19) AL-DH6 AL-DQ6 AL-D6 .94 (24) 1.18 (30) ø24 .94" .94 (24) .51 (13) .30 (7.5) .51 (13) .30 (7.5) .51 (13) .01 (0.3) www.idec.com Water-proof Gasket .01 (0.3) Water-proof Gasket .01 (0.3) .30 (7.5) Water-proof Gasket USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-49 Miniature Switches & Pilot Devices ø16mm - L6 Series Dimensions con’t AL-B6 H6-VL2 1.85 (47) .24 (6) .08 (2) .69 (17.6) .59 (15) .16 (4) .83 (21) .47 (12) .10 (2.5) .70 (17.8) Switches & Pilot Devices A2 AL-BM6 TOP Marking Side .70 (18) .65 (16.5) Gasket Locking Ring LED Lamp Internal Circuit LED Chip Protective Diode Zener Diode A2-50 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices ø16mm - L6 Series General Instructions Pushbutton Assembly Lamp Installation Lamps can be replaced in two ways: A2 Switches & Pilot Devices 1. If contacts are accessible (or pushbutton not installed in a panel) then it is easiest to first remove the contacts from the operator. This will allow easy access to the lamp/lamp-holder assembly. Grab lamp, depress slightly, and turn counter clockwise. Lamp can then be removed by pushing it back through the lamp holder. 2. If contacts are not accessible, then the lamp can be replaced by first removing the lens from the operator. Just pull lens straight out either with a fingernail or optional lens removal tool (MT-101). Lamp/lampholder assembly can then be removed with lamp removal tool (OR-44). Insert lamp removal tool through operator, depress slightly, turn counter clockwise, then pull lamp/lamp-holder assembly out. Lamp can then be removed by pushing it back through the lamp holder. Engraving Lenses All buttons and lenses can be engraved directly on the outside surface. Illuminated lenses also allow for engraving on a plate that is underneath the colored section of the lens. Remove the colored section of the lens by pulling on the edge while simultaneously unhooking it from the latches on the lens holder. The marking plate will then be accessible. It can then be engraved or a thin marked insert (such as mylar or paper) can be sandwiched between the marking plate and colored section of the lens. Latches Recess Engraving Area Color Lens Marking Plate Lens Holder Panel Mounting Before any unit can be mounted into a panel, the contact block must be removed. Slide metal locking lever and pull contact off. Loosen and remove the locking ring and square anti-rotation ring from the operator and insert operator through panel cutout from the front of the panel. Slide on anti-rotation ring and tighten locking ring, using locking ring wrench (MT-001). Slide contact block onto operator, observing TOP marking on both parts. Slide metal locking lever in direction indicated by LOCK. The yellow plastic safety lever lock can then be snapped onto the locking lever; this will prevent vibration or maintenance actions from releasing the contact from the operator. PCB Mounting Being able to separate the contacts from the operator allows for assembly of the front panel components (operator and lens) to be performed in tandem with the PC board assembly and soldering. For applications where multiple rows of pushbuttons are mounted closely together, or where other components may obstruct access to the contact locking lever, be sure to include access holes in the PC board (refer to PC board layout dimensions for location). Also be sure to allow for space above and to the side of contact to ensure that no components block the contact block locking lever. PC board pins are designed to rest on the PCB, take this into consideration to ensure that pins do not short closely spaced traces. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A2-51 Oiltight Switches & Pilot Devices ø22mm - HW Series HW Series — 22mm IEC Style Global Pushbuttons Switches & Pilot Devices A3 HW: The Best Engineered Switch in the World Key features include: • Locking lever removable contact blocks • Finger-safe IP20 contacts as standard, other terminal styles available • Tamperproof construction • All E-stops meet EN418 and are compliant with SEMI S2 standards • Worldwide approvals • Easy to assemble • Available assembled or as sub-components • Choice of black plastic or metallic front bezels • Incandescent or LED illumination • Transformer or full voltage • Slow make double break self cleaning contacts File No. E68961 A3-52 File No. LR92374 www.idec.com IDEC’s HW switches are “The best engineered switch in the world” for a reason. Carrying the CE mark, UL, CSA, CCC (Chinese), and TUV approvals, these switches are designed for use in almost any part of the world. Complete with finger-safe contact blocks offering IP20 protection, these 7/8" (22mm) switches include illuminated and non-illuminated pushbuttons, pilot lights, selector switches, and emergency stop switches. All switches also incorporate mechanically keyed safety locking levers, ensuring correct installation and maintaining safety in high-vibration applications. Registration No. R9551089 (E-stops) Registration No. R50054316 (Dual Pushbuttons) Registration No. J9650511 (Pilot Lights) Registration No. J9551458 (all other switches) Certificate No. 2005010305145656 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices Conforming to Standards Approvals File No. E68961 EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 File No. LR92374 Certificate No. 2005010305145656 Specifications A3 Operating Temperature Vibration Resistance Operation: –25 to +50°C (without freezing), Storage: –40 to +70°C (without freezing) Shock Resistance Electric Shock Protection Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) Mechanical Life Pollution Degree (conforming to IEC60947-1) 980m/sec2 (100G) conforming to IEC6068-2-7 Class 0 conforming to IEC60536 IP65 (from front of the panel) IP20 (Type HW-F contact block) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (from front of panel) Momentary pushbuttons: 5,000,000 (900 operations per hour), All other switches: 500,000 3 for switches not using a transformer, 2 for switches using a transformer AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) 600V Less than 4kV, conforming to IEC60947-1 4kV for contact circuit, 2.5kV for lamp circuit 10 Amp 5 mA at 3V AC/DC Slow break NC or NO, self-cleaning 5.5mm to 10mm travel to latch 45N minimum force to latch 10mm maximum travel 1,800 operations per hour maximum for a Pushlock Turn Reset 900 operations per hour maximum for a Push-Pull Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (maintained) Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Conforming to CENELEC EN50005 0.8 N m (7.1 in lb.) 10A 250V fuse conforming to IEC60269-1 Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Initial contact resistance of 50mΩ or less 4mm (NO and NC), 2mm (NO-EM and NC-LB) Reference Value: 1/4 HP @ 120V (1ø non-reversing), 1HP @ 240V (3ø non-reversing) MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Incandescent: 1 W LEDs: 6V/17mA max, 12V & 24V/11mA max, 120 & 240V/10mA max 40 A (40 ms) Silver (gold plated contacts available - contact IDEC) 10 to 55Hz, 98m/sec2 (10G) conforming to IEC6068-2-6 Rated Operational Characteristics Rated Insulation Voltage Rated Switching Over-Voltage Rated Impulse Withstanding Voltage Rated Thermal Current Minimum Switching Capacity Contact Operation Positive Action Operation (Emergency Stops with NC contacts) Operating Force Terminal Referencing Recommended Terminal Torque External Short-Circuit Protection Applicable Wire Size Contact Resistance Contact Gap Horsepower Rating Electrical Reliability Lamp Ratings Maximum Inrush Current Contact Material Contact Ratings CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Contact Block Type HW-C/HW-F /HW-G Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Operational Voltage Operational Current AC 50/60 Hz DC 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A — DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — 1. For dimensions, see page A3-100. 2. For life expectancy derating curves, see page A3-105. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-53 Switches & Pilot Devices Registration No. R9551089 (E-stops) Registration No. J9551458 (all other switches) Registration No. J9650511 (Pilot Lights) Characteristics ø22mm - HW Series Oiltight Switches & Pilot Devices ø22mm - HW Series Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Contact Plastic Bezel Style Momentary Maintained Switches & Pilot Devices A3 Metal Bezel Momentary Maintained Round Flush 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW1B-M1F10-➀ HW1B-M1F01-➀ HW1B-M1F11-➀ HW1B-M1F20-➀ HW1B-M1F02-➀ HW1B-M1F22-➀ HW1B-A1F10-➀ HW1B-A1F01-➀ HW1B-A1F11-➀ HW1B-A1F20-➀ HW1B-A1F02-➀ HW1B-A1F22-➀ HW4B-M1F10-➀ HW4B-M1F01-➀ HW4B-M1F11-➀ HW4B-M1F20-➀ HW4B-M1F02-➀ HW4B-M1F22-➀ HW4B-A1F10-➀ HW4B-A1F01-➀ HW4B-A1F11-➀ HW4B-A1F20-➀ HW4B-A1F02-➀ HW4B-A1F22-➀ 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW1B-M2F10-➀ HW1B-M2F01-➀ HW1B-M2F11-➀ HW1B-M2F20-➀ HW1B-M2F02-➀ HW1B-M2F22-➀ HW1B-A2F10-➀ HW1B-A2F01-➀ HW1B-A2F11-➀ HW1B-A2F20-➀ HW1B-A2F02-➀ HW1B-A2F22-➀ HW4B-M2F10-➀ HW4B-M2F01-➀ HW4B-M2F11-➀ HW4B-M2F20-➀ HW4B-M2F02-➀ HW4B-M2F22-➀ HW4B-A2F10-➀ HW4B-A2F01-➀ HW4B-A2F11-➀ HW4B-A2F20-➀ HW4B-A2F02-➀ HW4B-A2F22-➀ 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW1B-M3F10-➀ HW1B-M3F01-➀ HW1B-M3F11-➀ HW1B-M3F20-➀ HW1B-M3F02-➀ HW1B-M3F22-➀ HW1B-A3F10-➀ HW1B-A3F01-➀ HW1B-A3F11-➀ HW1B-A3F20-➀ HW1B-A3F02-➀ HW1B-A3F22-➀ HW4B-M3F10-➀ HW4B-M3F01-➀ HW4B-M3F11-➀ HW4B-M3F20-➀ HW4B-M3F02-➀ HW4B-M3F22-➀ HW4B-A3F10-➀ HW4B-A3F01-➀ HW4B-A3F11-➀ HW4B-A3F20-➀ HW4B-A3F02-➀ HW4B-A3F22-➀ 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW1B-M4F10-➀ HW1B-M4F01-➀ HW1B-M4F11-➀ HW1B-M4F20-➀ HW1B-M4F02-➀ HW1B-M4F22-➀ HW1B-A4F10-➀ HW1B-A4F01-➀ HW1B-A4F11-➀ HW1B-A4F20-➀ HW1B-A4F02-➀ HW1B-A4F22-➀ HW4B-M4F10-➀ HW4B-M4F01-➀ HW4B-M4F11-➀ HW4B-M4F20-➀ HW4B-M4F02-➀ HW4B-M4F22-➀ HW4B-A4F10-➀ HW4B-A4F01-➀ HW4B-A4F11-➀ HW4B-A4F20-➀ HW4B-A4F02-➀ HW4B-A4F22-➀ Round Extended 29mm Mushroom Head 40mm Mushroom Head 60mm Jumbo Mushroom Head Square Flush Square Extended 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW1B-M5F10-➀* HW1B-M5F01-➀* HW1B-M5F11-➀* HW1B-M5F20-➀* HW1B-M5F02-➀* HW1B-M5F22-➀* — — — 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW2B-M1F10-➀ HW2B-M1F01-➀ HW2B-M1F11-➀ HW2B-M1F20-➀ HW2B-M1F02-➀ HW2B-M1F22-➀ HW2B-A1F10-➀ HW2B-A1F01-➀ HW2B-A1F11-➀ HW2B-A1F20-➀ HW2B-A1F02-➀ HW2B-A1F22-➀ — — 1NO 1NC 1NO-1NC 2NO 2NC 2NO-2NC HW2B-M2F10-➀ HW2B-M2F01-➀ HW2B-M2F11-➀ HW2B-M2F20-➀ HW2B-M2F02-➀ HW2B-M2F22-➀ HW2B-A2F10-➀ HW2B-A2F01-➀ HW2B-A2F11-➀ HW2B-A2F20-➀ HW2B-A2F02-➀ HW2B-A2F22-➀ — — ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N* * Grey is available for Round Flush models only. 1. In place of ➀, specify the Button Color Code. 2. *Jumbo mushroom available only in red, green, black, and yellow. 3. For nameplates and accessories, see page A3-96 and A3-98. 4. For dimensions, see page A3-100. 5. For sub-assembly part numbers, see page A3-56. A3-54 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Non-Illuminated Pushbuttons (Partial-Assemblies) Contact Assembly + Operator Assembly + Complete Switch A3 Style Metal Bezel Plastic Bezel Square Flush Round Flush Momentary HW1B-M1-➀ Metal Bezel Momentary HW2B-M1-➀ – Maintained HW2B-A1-➀ – Momentary HW2B-M2-➀ – Maintained HW2B-A2-➀ – HW4B-M1-➀ Square Extended Maintained HW1B-A1-➀ HW4B-A1-➀ Round Extended Momentary HW1B-M2-➀ HW4B-M2-➀ Maintained HW1B-A2-➀ HW4B-A2-➀ 1. In place of ➀, specify the Button Color Code from table below. 2. For complete sub-assemblies, see page A3-56. Part Numbers: Contact Assemblies Style Contacts Standard Fingersafe Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 Spring Up Terminal Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 29mm Mushroom Head Momentary HW1B-M3-➀ HW4B-M3-➀ Maintained HW1B-A3-➀ HW4B-A3-➀ Momentary HW1B-M4-➀ HW4B-M4-➀ Part Number 40mm Mushroom Head ① Button Color Code Maintained HW1B-A4-➀ HW4B-A4-➀ 60mm Mushroom Head Momentary HW1B-M5-➀* – Color Code Black B Green G Red R Blue S White W Yellow Y Grey N* *Grey is available for round flush only. *60mm mushroom available in red, green, black and yellow only. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-55 Switches & Pilot Devices Part Numbers: Operator Assemblies Style Plastic Bezel Oiltight Switches & Pilot Devices ø22mm - HW Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks Adaptor & Safety Lever Lock + + Anti-Rotation Ring + Operator + Button = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators Part Numbers: Buttons Part Numbers: Contact Blocks Plastic Bezel Metal Bezel Style Round Flush/Extended Style 1NO 1NC Momentary HW1B-M0 HW4B-MO Style Part Number Round Flush Standard Fingersafe Contacts (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW1A-B1-➀ Round Extended Maintained HW1B-A0 HW4B-AO Spring-Up Terminal Contacts Ø 29mm Mushroom Ø 40mm Mushroom Momentary HW1B-M0L HW4B-MOL HW1A-B2-➀ HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) Ø 29mm Mushroom Cap HW1A-B3-➀ Exposed Screw Terminal Contacts Maintained HW1B-A0L HW4B-AOL HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Ø40mm Mushroom Cap HW1A-B4-➀ Ø 60mm Jumbo Mushroom Square Flush Dummy Block Momentary HW1B-M5-➀* – HW2A-B1-➀ TW-DB Square Flush Extended Square Extended Momentary HW2B-M0 – HW2A-B2-➀ Maintained HW2B-A0 1. In place of ➀, specify the Button Color Code from table below. 2. *60mm mushroom operator includes non-removable button (available in red, black, green and yellow only). 3. For nameplates and accessories, see page A3-96. 4. For dimensions, see page A3-100. ① Button Color Code Color Code Color – 1. All assembled part numbers in catalog include standard (HW-F...) contacts. Part Number: Contact 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” Block Mounting Adaptor (safety lever lock included) from the part number (Ex. HW1B-M1F11-R Part becomes HW1B-M111-R). Style Number 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. All contacts (including non-fingersafe versions) are UL, CSA, and IEC compliant and carry the HW-CB2C CE mark. Code Black B White W Green G Yellow Y Red R Grey N† Blue S 1. HW1B-M5 available only in black, red green and yellow. Part Numbers: Anti-Rotation Ring Appearance Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from inadvertently unlocking contacts. 2. †Grey available for round flush only. A3-56 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Pushbuttons (Assembled) Ø 40mm Head Push–Pull HW4B-Y2F10-➀† HW4B-Y2F01-➀† HW4B-Y2F11-➀† HW4B-Y2F02-➀† HW4B-Y2F20-➀† HW1B-V3F10-R* HW1B-V3F01-R* HW1B-V3F11-R* HW1B-V3F20-R* HW1B-V3F02-R* HW4B-V3F10-R* HW4B-V3F01-R* HW4B-V3F11-R* HW4B-V3F20-R* HW4B-V3F02-R* HW1B-V4F10-➀† HW1B-V4F01-➀† 1NC 1NO-1NC HW1B-V4F11-➀† 2NO HW1B-V4F20-➀† 2NC HW1B-V4F02-➀† HW4B-V4F10-➀† HW4B-V4F01-➀† HW4B-V4F11-➀† HW4B-V4F20-➀† HW4B-V4F02-➀† 1NO 1NC 1NO-1NC 2NO 2NC HW1B-V4F10-R-EMO-2 HW1B-V4F01-R-EMO-2 HW1B-V4F11-R-EMO-2 HW1B-V4F20-R-EMO-2 HW1B-V4F02-R-EMO-2 HW4B-V4F10-R-EMO-2 HW4B-V4F01-R-EMO-2 HW4B-V4F11-R-EMO-2 HW4B-V4F20-R-EMO-2 HW4B-V4F02-R-EMO-2 1NO 1NC 1NO-1NC 2NO 2NC HW1B-X4F10-R* HW1B-X4F01-R* HW1B-X4F11-R* HW1B-X4F20-R* HW1B-X4F02-R* HW4B-X4F10-R* HW4B-X4F01-R* HW4B-X4F11-R* HW4B-X4F20-R* HW4B-X4F02-R* 1NO 1NC 1NO-1NC 2NO 2NC HW1B-V5F10-R* HW1B-V5F01-R* HW1B-V5F11-R* HW1B-V5F20-R* HW1B-V5F02-R* Ø 29mm Head Pushlock Turn Reset 1NO 1NC 1NO-1NC 2NO 2NC Ø 40mm Head Pushlock Turn Reset 1NO Ø 40mm Head EMO Pushlock Turn Reset ERGENCY EM STOP Style Part Number 60mm Diameter “Emergency Stop” HWAV-27† 60mm Diameter Blank HWAV-0 80mm Diameter “Emergency Stop“ (for jumbo mushroom use) HWAV5-27 † HWAV-27 comes marked “Emergency Stop” as shown in drawing. Ø 40mm Head Pushlock Key Reset Ø 60mm Head Pushlock Turn Reset Part Numbers: E-Stop Shrouds Style Part Number HW9Z-KG1-TK2120 – Ø 40mm Head Unibody Pushlock Turn Reset 1NO-1NC HW1E-BV4F11-R* 2NC HW1E-BV4F02-R* 1NO-2NC HW1E-BV412R-TK2093-1** Part Numbers: Illuminated Emergency Stop Pushbuttons Illumination Style Contact Type LED Incandescent 1NO-1NC 2NC 2NC (with active lamp circuit) 1NO-1NC (with active lamp circuit) 1NO-1NC 2NC 1NO-1NC (with active lamp circuit) 2NC (with active lamp circuit) A3 HW9Z-KG2-TK2120 – Not applicable for 60mm mushroom. Part Number HW1E-LV4F11QD-R*-➂ HW1E-LV4F02QD-R*-➂ HW1E-TV4F02QD-R*-➂ HW1E-TV4F11QD-R*-➂ HW1E-LV4F11Q-R*-➂ HW1E-LV4F02Q-R*-➂ HW1E-TV4F11Q-R*-➂ HW1E-TV4F02Q-R*-➂ Terminal Numbering (Unibody only) Models Terminal Number 1NO-1NC NO = .3/.4, NC = .1/.2 2NC NC = 11/12, NC = 21/22 HW1E-L HW1E-T Lamp + = X2, Lamp - = X1 1. * Available in Red only. ➂ Full Voltage 2. † Available in red or yellow (insert color code in place of ➀) Voltage 3. In place of ➂, specify Full Voltage Code. 4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an 6VAC/DC extra degree of safety and reliability for critical emergency stop functions. 12VAC/DC 5. In the illuminated version, the light is independent of the switch action (except active lamp circuit model). 24VAC/DC 6 For nameplates and accessories, see page A3-96. 7 For dimensions, see page A3-100. 8. For sub-assembly part numbers, see next page. 9. All HW series E-stops comply with EN418, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator. 10. “Active Lamp Circuit” consists of a built-in Normally Open contact in series with the lamp. This allows the lamp to illuminate only when the button is pressed and eliminates the need for external jumpering. 11. Replacement Lens is HWLV-LENSR. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Code Code 6V 12V 24V A3-57 Switches & Pilot Devices HW1B-Y2F10-➀† HW1B-Y2F01-➀† HW1B-Y2F11-➀† HW1B-Y2F02-➀† HW1B-Y2F20-➀† 1NO 1NC 1NO-1NC 2NC 2NO Part Numbers: Nameplates HWAV–Yellow Plastic Ø 60mm Part Numbers: Non-Illuminated Emergency Stop Pushbuttons Style Contact Plastic Bezel Metal Bezel Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Pushbuttons (Partial-Assemblies) Contact Assembly + Anti-Rotation Ring + Operator Assembly + Complete Switch Switches & Pilot Devices A3 Part Numbers: Operators Style Plastic Bezel Metal Bezel HW1B-V3R* HW4B-V3R* Part Numbers: Anti-Rotation Ring Appearance Part Number Ø 29mm Head Pushlock Turn Reset HW9Z-RL Use with notched panel cutout to prevent unit rotation. Ø 40mm Head Pushlock Turn Reset red HW1B-V4R HW4B-V4R yellow HW1B-V4Y HW4B-V4Y Ø 40mm Head EMO Pushlock Turn Reset HW1B-V4R-EMO-2* Ø 40mm Head Push-Pull HW4B-V4R-EMO-2* red HW1B-Y2R HW4B-Y2R yellow HW1B-Y2Y HW4B-Y2Y HW1B-X4R* HW4B-X4R* HW1B-V5R* – Ø 40mm Head Pushlock Key Reset Ø 60mm Head Pushlock Turn Reset 1. *Available in red only. 2. All HW Series Emergency Stop operators include non-removable color caps. 3. All HW Series Emergency Stop operators comply with EN418 “E-Stop Addendum to the Low Voltage Directive” (when used as part of a complete HW series Emergency Stop Pushbutton). 4. All HW series Emergency Stop switches comply with SEMI S2 standards. Part Numbers: Contact Assemblies Style Contacts Part Number Standard Fingersafe Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 Spring Up Terminal Contacts 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 A3-58 www.idec.com Gold contact option is available for spring-up terminals. Add suffix “MAU” to end of part number. For example, HW-CB20 becomes HW-CB20-MAU. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Pushbuttons (Sub-Assembled) Contact Blocks + Adaptor & Safety Lever Lock + Anti-Rotation Ring + Operator = Complete Part A3 Part Numbers: Contact Blocks Description Metal Ø 29mm Head Pushlock Turn Reset 1NO HW1B-V3R* Ø 40mm Head Pushlock Turn Reset Part Number red HW4B-V3R* HW1B-V4R HW4B-V4R yellow HW1B-V4Y HW4B-V4Y 1NC Standard Fingersafe (IP20) Spring-Up Terminal Contacts Ø 40mm Head EMO Pushlock Turn Reset HW1B-V4R-EMO-2* HW4B-V4R-EMO-2* HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-G10-MAU (gold contacts) HW-G01-MAU (gold contacts) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Exposed Screw Terminal Contacts Ø 40mm Head Push-Pull red HW1B-Y2R yellow HW1B-Y2Y HW4B-Y2R HW4B-Y2Y Dummy Block Ø 40mm Head Pushlock Key Reset HW1B-X4R* HW4B-X4R* Ø 60mm Head Pushlock Turn Reset HW1B-V5R* 1. *Available in red only. 2. All Emergency Stop Buttons are non-removable from the operator. Part Number: Contact Block Mounting Adaptor (safety lever lock included) Style Part Number – TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. (except unibody) 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 4. All contacts (including exposed screw) are UL, CSA, and IEC compliant and carry the CE mark. Part Numbers: Anti-Rotation Ring Appearance Part Number HW9Z-RL HW-CB2C Use with notched panel cutout to prevent unit rotation. 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-59 Switches & Pilot Devices Part Numbers: Emergency Stop Operators Style Plastic Oiltight Switches & Pilot Devices ø22mm - HW Series Emergency Stop Stations Part Numbers: Emergency Stop Stations Description Contacts Ø 40mm Pushlock Turn Reset Ø 29mm Pushlock Turn Reset Ø 40mm Push-Pull Reset Ø 40mm Pushlock Key Reset Metal Bezel 1NO-1NC HW1X-BV411-R* HW4X-BV411-R* 2NC HW1X-BV402-R* HW4X-BV402-R* 1NO-1NC HW1X-BV311-R* HW4X-BV311-R* 2NC HW1X-BV302-R* HW4X-BV302-R* 1NO-1NC HW1X-BY411-R* HW4X-BY411-R* 2NC HW1X-BY402-R* HW4X-BY402-R* 1NO-1NC HW1X-BX411-R* HW4X-BX411-R* 2NC HW1X-BX402-R* HW4X-BX402-R* 1. * Available in Red only. 2. Maximum of two contact blocks. 3. Available as completed unit only. 4. Box is supplied with yellow top and black bottom only. Part Numbers: Nameplates for Emergency Stop Stations Part Number NSA-Aluminum Color Blank Engraved Black Red NSA-0 NSA-0R NSA-*R NSA-*R ø 25 .5 m m 36mm 34mm 1. In place of * please insert the word, letters, or numbers you would like engraved. For standard engravings, see page A3-96. 2. For specifications on engravings, please consult factory. Part Numbers: Base Mount Contact Blocks Configuration Part Number 1NO HW-S10 1NC HW-S01 Part Numbers: Plug Adaptors Type Part Number G1/2 HW9Z-G PG16 HW9Z-PG Panel Mount Dimensions A 58 58 42.4 70 58 58 Switches & Pilot Devices A3 Plastic Bezel HW1B-V4R Box Cover Mouting Screws Box Cover Box Base 2-ø4.6 A3-60 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Pilot Lights (Assembled) Part Numbers: Pilot Lights Style Round Flush Full Voltage Plastic Bezel Metal Bezel HW1P-1FQ➃-➁-➂ HW4P-1FQ➃-➁-➂ HW4P-1FH2➃-➁ HW4P-1FM4➃-➁ HW4P-1FT8➃-➁ 120V AC 240V AC 480V AC HW1P-1FH2➃-➁ HW1P-1FM4➃-➁ HW1P-1FT8➃-➁ (Full Voltage type shown) DC-DC Converter* 110V DC HW1P-1D2➃-➁ Dome Full Voltage – HW1P-2FQ➃-➁-➂ HW4P-2FQ➃-➁-➂ HW4P-2FH2➃-➁ HW4P-2FM4➃-➁ HW4P-2FT8➃-➁ Transformer 120V AC 240V AC 480V AC HW1P-2FH2➃-➁ HW1P-2FM4➃-➁ HW1P-2FT8➃-➁ (Full Voltage type shown) DC-DC Converter* 110V DC HW1P-2D2➃-➁ – Square Flush Full Voltage HW2P-1FQ➃-➁-➂ – (Transformer type shown) Transformer 120V AC 240V AC 480V AC HW2P-1FH2➃-➁ HW2P-1FM4➃-➁ HW2P-1FT8➃-➁ – DC-DC Converter* 110V DC HW2P-1D2➃-➁ – LED HW1P-5Q4-➁ Incandescent HW1P-5Q7-➁ Jumbo Dome Full Voltage** 24V AC/DC A3 Switches & Pilot Devices Transformer – 1. In place of ➁, specify the Lens/LED Color Code. 2. In place of ➂specify the Full Voltage Code from table below. 3. In place of ➃ specify Lamp Type Code. 4. *DC-DC convertor voltage input from 90-140V DC, comes with spring up terminals only. 5. **Available with spring up terminals and 24V only. 6. For nameplates and accessories, see page A3-96. 7 For dimensions, see page A3-100. ➁ Lens/LED Color Code Color Code ➂ Full Voltage Code ➃ Lamp Type Code Lamp Code Amber A 6V AC/DC 6 Incandescent Blank Green G 12V AC/DC 12 LED D Red R 24V AC/DC 24 Voltage Code Blue S 120V AC (LED only) 120 White W 240VAC (LED only) 240 Yellow Y www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-61 Oiltight Switches & Pilot Devices ø22mm - HW Series Pilot Lights (Partial-Assemblies) Full Voltage Models Operator/Lens Switches & Pilot Devices A3 Part Numbers: Operator/Lens Plastic Bezel Style + Lamp Metal Bezel = Part Numbers: Lamps Voltage Type Round Flush LED HW1P-1FQ0-➁ HW4P-1FQ0-➁ Dome HW1P-2FQ0-➁ HW4P-2FQ0-➁ Incandescent Square Flush HW2P-1FQ0-➁ Complete Pilot Light Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 30V AC/DC IS-30 1. In place of ➁, specify the LED Color Code from table on previous page. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. – 1. In place of ➁, specify the Lens Color Code from table on previous page. 2. Operator/Lens assembly for use with standard transformers only6, not spring up terminal type. Transformer Models Transformer/Lamp Part Numbers: Operator/Lens Style Plastic Bezel + Operator/Lens Metal Bezel Round Flush HW1P-1F0-➁ HW4P-1F0-➁ Dome HW1P-2F0-➁ HW4P-2F0-➁ Square Flush HW2P-1F0-➁ – = Complete Part Numbers: Transformer/Lamp Item Voltage Part Number 120V AC with LED HW-FH2-➁ 240V AC with LED HW-FM4-➁ 480V AC with LED HW-FT8-➁ 120V AC with Incandescent HW-FH2 240V AC with Incandescent HW-FM4 480V AC with Incandescent HW-FT8 1. In place of ➁, specify the LED Color Code from table on previous page. 2. All transformers have a 6V AC secondary voltage. 3. LED/Lamp supplied with transformer partial assembly. In place of ➁, specify the Lens Color Code from table on previous page. A3-62 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Pilot Lights (Sub-Assembled) Transformer* + Lamp + Anti-Rotation Ring + Operator + Lens = Complete Part A3 Round Flush Plastic Bezel Metal Bezel Part Numbers: Transformer Units Style Voltage Part Number LED/Incandescent Standard HW1P-1FQ0 HW4P-1FQ0 Spring Up Terminals HW1P-1Q0 HW4P-1Q0 Standard HW1P-10 HW4P-10 Full Voltage (HW1P-10 shown) (6V secondary voltage) Spring Up Terminals HW1P-100 Standard HW1P-2FQ0 HW4P-2FQ0 HW1P-2Q0 Part Numbers: Lamps Type Voltage HW4P-2Q0 LED Standard HW1P-20 HW4P-20 Transformer (HW1P-20 shown) Square Flush (HW2P-10 shown) Spring Up Terminals HW1P-200 Standard HW2P-1FQ0 Full Voltage Dome Incandescent Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ Amber A 24V AC/DC LSTD-2➁ Green G 120V AC LSTD-H2➁ Red R 240V AC LSTD-M4➁ Blue S 6.3V AC/DC IS-6 White W Spring Up Terminals HW2P-1Q0 12V AC/DC IS-12 Yellow Y Standard HW2P-10 – 24V AC/DC IS-24 Spring Up Terminals HW2P-100 – Part Number HW1A-P1-➁ HW1A-P2-➁ 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. Part Numbers: Anti-Rotation Ring Appearance Part Number Use with notched panel cutout to prevent unit rotation. HW9Z-RL Jumbo Dome Pilot Light Replacement Parts Description Item Replacement Jumbo Dome Operator Replacement Jumbo Dome Lens HW2A-P1-➁ In place of ➁, specify the Lens Color Code. www.idec.com Replacement LED Lamps for HW Jumbo Dome Part Number LED Type HW1P-5Q0 Incandesccent Type* HW1P-5Q7 HW1A-P5① Polycarbonate Lens Replacement LED Diffusing Lens Square/ Flush ➁ Lens/LED Color Code Color Code – 1. Transformer type requires separate transformer & lamp. Must select correct transformer bases on standard or spring up terminal type. Use 6V lamps or LEDs. 2. Full voltage type only requires lamp. Round/Flush – Transformer Part Numbers: Lenses Style HW-RD0 (with spring up terminals)* 1. *To use spring up terminal type, must use transformer type operator designed for spring up transformer. 2. ** DC-DC converter voltage input from 90-140V DC. – Full Voltage Spring Up Terminals 110V DC** 240V AC Transformer Dome 480V AC HW-FH20 HW-MH20 (with spring up terminals)* HW-FM40 HW-MM40 (with spring up terminals)* HW-FT80 HW-RT80 (with spring up terminals)* 120V AC ① = (A, G, R, S, W, Y) HW9Z-PP5C LED Lamp LSTDB-2① ① = (A, G, R, S, W, Y) *Operator comes with incandescent bulb. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-63 Switches & Pilot Devices * Not applicable to full voltage units. Part Numbers: Operators Style Type Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons Style Switches & Pilot Devices A3 Description Flush Metal Bezel Momentary Maintained 1NO 1NC 1NO-1NC 2NO HW1L-M1F10Q➃-➁-➂ HW1L-M1F01Q➃-➁-➂ HW1L-M1F11Q➃-➁-➂ HW1L-M1F20Q➃-➁-➂ HW1L-A1F10Q➃-➁-➂ HW1L-A1F01Q➃-➁-➂ HW1L-A1F11Q➃-➁-➂ HW1L-A1F20Q➃-➁-➂ HW4L-M1F10Q➃-➁-➂ HW4L-M1F01Q➃-➁-➂ HW4L-M1F11Q➃-➁-➂ HW4L-M1F20Q➃-➁-➂ HW4L-A1F10Q➃-➁-➂ HW4L-A1F01Q➃-➁-➂ HW4L-A1F11Q➃-➁-➂ HW4L-A1F20Q➃-➁-➂ 120V AC AC Transformer 120V 240V AC 240V AC 1NO-1NC 2NO 1NO-1NC 2NO HW1L-M1F11H2➃-➁ HW1L-M1F20H2➃-➁ HW1L-M1F11M4➃-➁ HW1L-M1F20M4➃-➁ HW1L-A1F11H2➃-➁ HW1L-A1F20H2➃-➁ HW1L-A1F11M4➃-➁ HW1L-A1F20M4➃-➁ HW4L-M1F11H2➃-➁ HW4L-M1F20H2➃-➁ HW4L-M1F11M4➃-➁ HW4L-M1F20M4➃-➁ HW4L-A1F11H2➃-➁ HW4L-A1F20H2➃-➁ HW4L-A1F11M4➃-➁ HW4L-A1F20M4➃-➁ Full Voltage 1NO 1NC 1NO-1NC 2NO HW1L-M2F10Q➃-➁-➂ HW1L-M2F01Q➃-➁-➂ HW1L-M2F11Q➃-➁-➂ HW1L-M2F20Q➃-➁-➂ HW1L-A2F10Q➃-➁-➂ HW1L-A2F01Q➃-➁-➂ HW1L-A2F11Q➃-➁-➂ HW1L-A2F20Q➃-➁-➂ HW4L-M2F10Q➃-➁-➂ HW4L-M2F01Q➃-➁-➂ HW4L-M2F11Q➃-➁-➂ HW4L-M2F20Q➃-➁-➂ HW4L-A2F10Q➃-➁-➂ HW4L-A2F01Q➃-➁-➂ HW4L-A2F11Q➃-➁-➂ HW4L-A2F20Q➃-➁-➂ 120V AC AC Transformer 120V 240V AC 240V AC 1NO-1NC 2NO 1NO-1NC 2NO HW1L-M2F11H2➃-➁ HW1L-M2F20H2➃-➁ HW1L-M2F11M4➃-➁ HW1L-M2F20M4➃-➁ HW1L-A2F11H2➃-➁ HW1L-A2F20H2➃-➁ HW1L-A2F11M4➃-➁ HW1L-A2F20M4➃-➁ HW4L-M2F11H2➃-➁ HW4L-M2F20H2➃-➁ HW4L-M2F11M4➃-➁ HW4L-M2F20M4➃-➁ HW4L-A2F11H2➃-➁ HW4L-A2F20H2➃-➁ HW4L-A2F11M4➃-➁ HW4L-A2F20M4➃-➁ Full Voltage 1NO 1NC 1NO-1NC 2NO HW1L-MF2F10Q➃-➁-➂ HW1L-MF2F01Q➃-➁-➂ HW1L-MF2F11Q➃-➁-➂ HW1L-MF2F20Q➃-➁-➂ HW1L-AF2F10Q➃-➀-➂ HW1L-AF2F01Q➃-➀-➂ HW1L-AF2F11Q➃-➀-➂ HW1L-AF2F20Q➃-➀-➂ HW4L-MF2F10Q➃-➁-➂ HW4L-MF2F01Q➃-➁-➂ HW4L-MF2F11Q➃-➁-➂ HW4L-MF2F20Q➃-➁-➂ HW4L-AF2F10Q➃-➀-➂ HW4L-AF2F01Q➃-➀-➂ HW4L-AF2F11Q➃-➀-➂ HW4L-AF2F20Q➃-➀-➂ 120V AC AC Transformer 120V 240V AC 240V AC 1NO-1NC 2NO 1NO-1NC 2NO HW1L-MF2F11H2➃-➁ HW1L-MF2F20H2➃-➁ HW1L-MF2F11M4➃-➁ HW1L-MF2F20M4➃-➁ HW1L-AF2F11H2➃-➁ HW1L-AF2F20H2➃-➁ HW1L-AF2F11M4➃-➁ HW1L-AF2F20M4➃-➁ HW4L-MF2F11H2➃-➁ HW4L-MF2F20H2➃-➁ HW4L-MF2F11M4➃-➁ HW4L-MF2F20M4➃-➁ HW4L-AF2F11H2➃-➁ HW4L-AF2F20H2➃-➁ HW4L-AF2F11M4➃-➁ HW4L-AF2F20M4➃-➁ Full Voltage 1NO 1NC 1NO-1NC 2NO HW1L-M4F10Q➃-➁-➂ HW1L-M4F01Q➃-➁-➂ HW1L-M4F11Q➃-➁-➂ HW1L-M4F20Q➃-➁-➂ HW1L-A4F10Q➃-➁-➂ HW1L-A4F01Q➃-➁-➂ HW1L-A4F11Q➃-➁-➂ HW1L-A4F20Q➃-➁-➂ HW4L-M4F10Q➃-➁-➂ HW4L-M4F01Q➃-➁-➂ HW4L-M4F11Q➃-➁-➂ HW4L-M4F20Q➃-➁-➂ HW4L-A4F10Q➃-➁-➂ HW4L-A4F01Q➃-➁-➂ HW4L-A4F11Q➃-➁-➂ HW4L-A4F20Q➃-➁-➂ 120V AC 120V AC Transformer 240V AC 240V AC 1NO-1NC 2NO 1NO-1NC 2NO HW1L-M4F11H2➃-➁ HW1L-M4F20H2➃-➁ HW1L-M4F11M4➃-➁ HW1L-M4F20M4➃-➁ HW1L-A4F11H2➃-➁ HW1L-A4F20H2➃-➁ HW1L-A4F11M4➃-➁ HW1L-A4F20M4➃-➁ HW4L-M4F11H2➃-➁ HW4L-M4F20H2➃-➁ HW4L-M4F11M4➃-➁ HW4L-M4F20M4➃-➁ HW4L-A4F11H2➃-➁ HW4L-A4F20H2➃-➁ HW4L-A4F11M4➃-➁ HW4L-A4F20M4➃-➁ 1NO 1NC 1NO-1NC 2NO 1NO-1NC 2NO 1NO-1NC 2NO HW2L-M1F10Q➃-➁-➂ HW2L-M1F01Q➃-➁-➂ HW2L-M1F11Q➃-➁-➂ HW2L-M1F20Q➃-➁-➂ HW2L-M1F11H2➃-➁ HW2L-M1F20H2➃-➁ HW2L-M1F11M4➃-➁ HW2L-M1F20M4➃-➁ HW2L-A1F10Q➃-➁-➂ HW2L-A1F01Q➃-➁-➂ HW2L-A1F11Q➃-➁-➂ HW2L-A1F20Q➃-➁-➂ HW2L-A1F11H2➃-➁ HW2L-A1F20H2➃-➁ HW2L-A1F11M4➃-➁ HW2L-A1F20M4➃-➁ Extended with Full Shroud Square Flush Full Voltage 120V AC AC Transformer 120V 240V AC 240V AC 1.In place of ➁ specify the Lens Color Code, in place of ➂ specify the Full Voltage Code and in place of ➃ specify Lamp Type Code. 2. For partial and sub-assembly part numbers, see pages A3-65 and A3-66. 3. For nameplates and accessories, see page A3-96. 4. For dimensions, see page A3-100. ➃ Lamp Type Code Lamp Code Incandescent Blank LED D A3-64 Plastic Bezel Momentary Maintained Full Voltage Extended 40mm Mushroom Head Contacts ➁ Lens Color Code Color Code – – – – ➂ Full Voltage Codes Voltage Code Amber A 6V AC/DC 6V Green G 12V AC/DC 12V Red R 24V AC/DC 24V Blue S 120V AC (LED only) 120V White W 240VAC (LED only) 240V Yellow Y* *40mm mushroom lenses not available in yellow www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Partial-Assemblies) Contact Assembly + Lamp* + Operator/Lens = Complete Switch A3 Part Numbers: Full Voltage Contact Assemblies Plastic Bezel Metal Bezel (order lamp separately) Style Flush Momentary HW1L-M1-➁ HW4L-M1-➁ Maintained HW1L-A1-➁ HW4L-A1-➁ Momentary HW1L-M2-➁ HW4L-M2-➁ Maintained HW1L-A2-➁ HW4L-A2-➁ Momentary HW1L-MF2-➁ HW4L-MF2-➁ Contacts 1NO 2NO 1NO/1NC 1NC 2NC Order lamp separately. Extended Part Numbers: Transformer Contact Assemblies (lamp included) Style Extended/Full shroud Contacts Part Number 1NO 2NO 1NC 1N0/1NC 1NO 2NO 1NC 1N0/1NC 1NO 2NO 1NC 1N0/1NC 1NO 2NO 1NC 1N0/1NC 1NO 2NO 1NC 1N0/1NC HW-FL10H2-➁ HW-FL20H2-➁ HW-FL01H2-➁ HW-FL11H2-➁ HW-FL10M4-➁ HW-FL20M4-➁ HW-FL01M4-➁ HW-FL11M4-➁ HW-FL10T8-➁ HW-FL20T8-➁ HW-FL01T8-➁ HW-FL11T8-➁ HW-FL10H2 HW-FL20H2 HW-FL01H2 HW-FL11H2 HW-FL10M4 HW-FL20M4 HW-FL01M4 HW-FL11M4 120V AC with LED Mushroom* Square Maintained HW1L-AF2-➁ HW4L-AF2-➁ Momentary HW1L-M4-➁* HW4L-M4-➁* 240V AC with LED Maintained HW1L-A4-➁* HW4L-A4-➁* 480V AC with LED Momentary HW2L-M1-➁ – Maintained HW2L-A1-➁ 120V AC with Incandescent 240V AC with Incandescent 1. In place of ➁, specify the Lens Color Code. 2. *Mushroom Lens not available in yellow. Part Numbers: Lamps Type Voltage LED Incandescent Part Number HW-FL10Q0 HW-FL20Q0 HW-FL11Q0 HW-FL01Q0 HW-FL02Q0 Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 30V AC/DC IS-30 ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y 1. In place of ➁, specify the LED Color Code from table below. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-65 Switches & Pilot Devices *Lamp is included in contact assembly for transformer models only. Part Numbers: Operators/Lens Type Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Sub-Assembled) Part Numbers: LED and Incandescent Illuminated Pushbuttons Transformer * + Contact Blocks + Lead Holder + Adaptor † + Lamp + Anti-Rotation Ring + Operator + Lens = Complete Part Switches & Pilot Devices A3 1. * Transformer not needed with full voltage types. 2. † Adaptor includes safety lever lock. Part Numbers: Lenses Style Round Flush Part Numbers: Operators Part Number Part Number Plastic Metal Bezel Bezel Style HW1A-L1-➁ Round Flush/Extended Round Extended HW1A-L2-➁ Extended with Full Shroud Ø 40mm Mushroom Cap ALW4BLU-➁* Ø 40mm Mushroom Head Momentary HW1L-M0 HW4L-M0 Maintained HW1L-A0 HW4L-A0 Momentary HW1L-MF0 HW4L-MF0 Maintained HW1L-AF0 HW4L-AF0 Momentary HW1L-M0L HW4L-M0L Maintained HW1L-A0L HW4L-A0L Momentary HW2L-M0 Maintained HW2L-A0 Square Flush Square Flush HW2A-L1-➁ – I. n place of ➁, specify the Lens Color Code. 2. *not available in yellow. ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y* *ALW4BLU not available in yellow. A3-66 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Pushbuttons (Sub- Assembled) con’t Part Numbers: Anti-Rotation Ring Appearance Part Number Part Numbers: Contact Blocks Description Part Number 1NO HW-F01 HW-F10R (early make) HW-F01R (late break) Part Number HW-G10 HW-G01 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ HW-G10R (early make) HW-G01R (late break) 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ HW-C10 HW-C01 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 HW-C10R (early make) HW-C01R (late break) 12V AC/DC IS-12 24V AC/DC IS-24 30V AC/DC IS-30 Part Numbers: Lamps Type Voltage Switches & Pilot Devices HW-F10 Use with notched panel cutout to prevent unit rotation Incandescent A3 Standard Fingersafe (IP20) HW9Z-RL LED 1NC Spring-Up Terminal Contacts Exposed Screw Terminal Contacts Dummy Block TW-DB 1. In place of ➁, specify the LED Color Code from table on previous page. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. Part Numbers: Lamp Circuit Components Style Description Terminals Part Number Lead Holder For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Dummy Block with Full Voltage Adaptor HW-LH3 Fingersafe HW-DA1FB Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1FB Exposed TW-DA1B 120VAC 240VAC 480VAC Fingersafe TW-F126B TW-F246B TW-F486B 120V 240V 480V Spring Up HW-T126 HW-T246 HW-L486 (6V secondary voltage) 120V 240V 480V Exposed TW-T126B TW-T246B TW-T486B DC-DC Converter 110VDC For use with odd number of contacts. Full Voltage Adaptor Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Style Part Number HW-CBL For use with even number of contacts. Transformer Unit 1. All assembled part numbers in catalog include standard (HWF...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1BM1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 1. Used to mount contact blocks to operator (first pair only). Lamp holder is built-in. 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. HW-L16D HW-GA1 “Dummy Block with full voltage adaptor” does not require the use of HW-LH3. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-67 Oiltight Switches & Pilot Devices ø22mm - HW Series Selector Switches (Assembled) Part Numbers: 2–Position Selector Switches Operator Position R L Mounting R Contact L Spring Return from Right Maintained 1NO 1 O X Knob Lever HW➄S-2TF10 HW➄S-2LF10 HW➄S-21TF10 HW➄S-21LF10 1NO- 1 1NC 2 O X X O Knob Lever HW➄S-2TF11 HW➄S-2LF11 HW➄S-21TF11 HW➄S-21LF11 1 2 O O X X Knob Lever HW➄S-2TF20 HW➄S-2LF20 HW➄S-21TF20 HW➄S-21LF20 2NO L Part Number R Part Number Part Numbers: 3–Position Selector Switches Mounting Contact Operator Position Handle L C Spring Return from Right Maintained C C R L Spring Return from Left L R Part Number C C L R L R Part Number Part Number 1 2 O O X O X X Knob Lever HW➄S-3TF11 HW➄S-3LF11 HW➄S-31TF11 HW➄S-31LF11 HW➄S-32TF11 HW➄S-32LF11 HW➄S-33TF11 HW➄S-33LF11 2NO 1 2 X O O O O X Knob Lever HW➄S-3TF20 HW➄S-3LF20 HW➄S-31TF20 HW➄S-31LF20 HW➄S-32TF20 HW➄S-32LF20 HW➄S-33TF20 HW➄S-33LF20 2NO1NC 1 2 3 X O O O O X O X O Knob HW➄S-3JTF21N1 — — — 2NO2NC 1 2 3 4 X O O X O O X X O X X O Knob HW➄S-3TF22 HW➄S-31TF22 HW➄S-32TF22 HW➄S-33TF22 1NO 3NC 1 2 3 4 O O O O X X O O X O X O X O O X Knob Lever HW➄S-4TF13N6 HW➄S-4LF13N6 2NO2NC 1 2 3 4 X O O O O X O O O O X O O O O X Knob Lever HW➄S-4TF22N3 HW➄S-4LF22N3 2 3 4 2 1 3 4 2NO2NC Mounting 1 Operator Position Contact Handle 1 Metal 4 Part Numbers: 5–Position Selector Switch Maintained Part Number Mounting Operator Position Plastic R Part Number Part Numbers: 4–Position Selector Switch ➄ Bezel Type Type Code Spring Return Two-Way 1NO1NC Contact Switches & Pilot Devices A3 Handle 1 1 2 3 4 X O O O 2 3 4 Handle Maintained Part Number 5 2 3 4 1 O X O O O O O O O O X O O O O X Knob Lever 5 HW➄S-5TF22N3 HW➄S-5LF22N3 1. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel. 2. Mounting refers to contact location on operator. See page A3-82. 3. For nameplates, see page A3-96. 4. Custom contact arrangements available. Contact IDEC for details. 5. Five position circuit cannot be made to make five independent contact closures, A3-68 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Selector Switches (Partial-Assemblies) Contact Assembly + Operator = Complete Part A3 Switches & Pilot Devices Part Numbers: Operators No. of Positions Description Maintained 2 Knob Operator (plastic bezel) (metal bezel) Spring Return from Right Maintained (standard cam) Maintained (S cam) Maintained (J cam) Lever Operator (plastic bezel) 3 Spring Return from Right Spring Return from Left 2-Way Spring Return 4 Maintained 5 Maintained Handle Plastic Bezel Metal Bezel Knob Lever Knob Lever Knob Lever Knob Knob Knob Lever Knob Lever Knob Lever Knob Lever Lever Lever HW1S-2T HW1S-2L HW1S-21T HW1S-21L HW1S-3T* HW1S-3L HW1S-3ST* HW1S-3JT* HW1S-31T HW1S-31L HW1S-32T HW1S-32L HW1S-33T HW1S-33L HW1S-4T HW1S-4L HW1S-5T HW1S-5L HW4S-2T HW4S-2L HW4S-21T HW4S-21L HW4S-3T* HW4S-3L HW4S-3ST* HW4S-3JT* HW4S-31T HW4S-31L HW4S-32T HW4S-32L HW4S-33T HW4S-33L HW4S-4T HW4S-4L HW4S-5T HW4S-5L 1. Knob operator includes knob. 2. * Three position operator is available with three different cams. 3. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). 4. For details of determining which cam to use, see page A3-79. Part Numbers: Contact Assemblies Style Contacts Part Number Standard Fingersafe Contacts Spring Up Terminal Contacts www.idec.com 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-69 Oiltight Switches & Pilot Devices ø22mm - HW Series Selector Switches (Sub-Assembled) Contact Blocks Adaptor and Safety Lever Lock + + Anti-Rotation Ring + Operator = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators # of Style Description Positions Plastic Bezel Metal Bezel Knob HW1S-2T HW4S-2T Lever HW1S-2 HW4S-2 Spring Return from Right Knob HW1S-21T HW4S-21T Lever HW1S-21 HW4S-21 Maintained (standard cam) Knob HW1S-3T* HW4S-3T* Handle Maintained 2 Knob Operator 3 Lever Operator HW1S-3* HW4S-3* Maintained (S cam) Knob HW1S-3ST* HW4S-3ST* Maintained (J cam) Spring Return from Right (standard cam) Spring Return from Left (standard cam) 2-Way Spring Return (standard cam) Knob HW1S-3JT* HW4S-3JT* Knob HW1S-31T HW4S-31T Lever HW1S-31 HW4S-31 Knob HW1S-32T HW4S-32T Lever HW1S-32 HW4S-32 Knob HW1S-33T HW4S-33T Lever HW1S-33 HW4S-33 4 Maintained 5 Maintained Lever Knob HW1S-4T HW4S-4T Lever HW1S-4 HW4S-4 Knob HW1S-5T HW4S-5T Lever HW1S-5 HW4S-5 1. Knob operator comes with handle. 2. * Three position operator is available with three different cams. 3. Operator cams are color coded (white=standard cam, red=S cam, black =J cam). 4. For details of determining which cam to use, see page A3-79. 5. To order colored handle type, knob/lever and inserts must be ordered separately, along with lever operator. See part numbers below. Part Numbers: Levers and Inserts Style Part Number Knob ① Handle/Insert Color Code ASWHHY-① Color Code Color Code Lever ASWHHL-① Lever Color Insert TW-HC1-① Black* B Red R Blue S Yellow Y Green G White† W * Lever color inserts not available in black. † Knob and lever not available in white. Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Part Appearance Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. Part Numbers: Contact Blocks Description Part Number 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F10R (early make) HW-F01 HW-F01R (late break) Spring-Up Terminal Contacts HW-G10 HW-G10R (early make) HW-G01 HW-G01R (late break) Exposed Screw Terminal Contacts HW-C10 HW-C10R (early make) HW-C01 HW-C01R (late break) Dummy Block TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1BM111-R). 3. Units with exposed screw terminals (HWC...) must be ordered as sub-components. Part Numbers: Anti-Rotation Ring Appearance Part Number HW9Z-RL A3-70 1. Use with notched panel cutout to prevent unit rotation. 2. Not required when using HW series nameplates. See page A3-96. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Key Switches (Assembled) A3 1 O X 1NO- 1 1NC 2 O X X O 1 O X 2 O X Contact Mounting Operator Position L 1NO 2NO Key Removable Option Codes Code Description Part Number Maintained Spring Return from Right R L L R R HW➄K-2AF10 HW➄K-21BF10 HW➄K-2AF11 HW➄K-21BF11 HW➄K-2AF20 HW➄K-21BF20 A Key retained in NO position (removable in all positions) B Key retained in right position only C Key retained in left position only D Key retained in left and right (3 position only) E Key retained in center only (3 position only) G Key retained right and center (3 position only) H Key retained left and center (3 position only) For more information on these options, contact your IDEC representative. Part Numbers: 3–Position Key Switches Part Number 1NO1NC 2NO 2NO2NC Mounting Contact Operator Position L 1 0 X X 2 0 0 X 1 X O O 2 O O X 1 X O O 2 O O X 3 O X X 4 X X O C Maintained Spring Return from Right Spring Return from Left Spring Return from Left & Right C C C C R L R L R L L R ➄ Bezel Type Type Code Plastic 1 Metal 4 R HW➄K-3AF11 HW➄K-31BF11 HW➄K-32CF11 HW➄K-33DF11 HW➄K-3AF20 HW➄K-31BF20 HW➄K-32CF20 HW➄K-33DF20 HW➄K-3AF22 HW➄K-31BF22 HW➄K-32CF22 HW➄K-33DF22 1. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table at right). 2. Key is removable in all maintained positions. Other key removable options available. 3. Two keys are supplied with all switches. 4. All standard operators are keyed alike (contact IDEC for special keys). 5. For nameplates, see page A3-96. 6. Custom contact arrangements available, contact IDEC for details. 7. Mounting refers to contact location on operator. See page A3-82. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-71 Switches & Pilot Devices Part Numbers: 2–Position Key Switches Oiltight Switches & Pilot Devices ø22mm - HW Series Key Switches (Partial-Assemblies) Contact Assembly + Operator = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators # of Positions 2 3 Description Plastic Bezel Metal Bezel Maintained HW1K-2A HW4K-2A Maintained, key remove left only HW1K-2B HW4K-2B Spring from Right HW1K-21B HW4K-21B Maintained, Standard Cam HW1K-3A HW4K-3A Maintained, Cam S HW1K-3SA HW4K-3SA Maintained, Cam J HW1K-3JA HW4K-3JA Spring Return from Right HW1K-31B HW4K-31B Spring Return from Left HW1K-32C HW4K-32C Two-Way Spring Return HW1K-33D HW4K-33D 1. Operator includes two keys. 2. All standard operators are keyed alike (contact IDEC for special keys). 3. Other key removable options available. See “Other Key Removable Option Codes” on next page. Part Numbers: Contact Assemblies Style Contacts Standard Fingersafe Contacts Spring Up Terminal Contacts A3-72 Part Number Key Removable Option Codes Code Description 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 A Key retained in NO position (removable in all positions) B Key retained in right position only C Key retained in left position only D Key retained in left and right (3 position only) 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 E Key retained in center only (3 position only) G Key retained right and center (3 position only) H Key retained left and center (3 position only) www.idec.com 1. For more information on these options, contact your IDEC representative. 2. Key retained in all spring-return positions. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Key Switches (Sub-Assembled) Contact Blocks + Adaptor & Safety Lever Lock + Anti-Rotation Ring + Operator = Complete Part A3 2 3 Plastic Bezel Metal Bezel Maintained HW1K-2A HW4K-2A Maintained, key remove left only HW1K-2B HW4K-2B Spring from Right HW1K-21B HW4K-21B Maintained, Standard Cam HW1K-3A HW4K-3A Maintained, Cam S HW1K-3SA HW4K-3SA Maintained, Cam J HW1K-3JA HW4K-3JA Spring Return from Right HW1K-31B HW4K-31B Spring Return from Left HW1K-32C HW4K-32C Two-Way Spring Return HW1K-33D HW4K-33D 1. Operator includes two keys. 2. All standard operators are keyed alike (contact IDEC for special keys). 3. Other key removable options available. See table below. Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Style Part Number Part Numbers: Contact Blocks Description Switches & Pilot Devices Part Numbers: Operators # of Description Positions Part Number 1NO 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Spring-Up Terminal Contacts Exposed Screw Terminal Contacts Dummy Block TW-DB HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. Key Removable Option Codes Code Description 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HWG...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Part Numbers: Anti-Rotation Ring Appearance Part Number A Key retained in NO position (removable in all positions) B Key retained in right position only C Key retained in left position only D Key retained in left and right (3 position only) E Key retained in center only (3 position only) G Key retained right and center (3 position only) H Key retained left and center (3 position only) HW9Z-RL 1. Use with notched panel cutout to prevent unit rotation (not included with assembled units). 2. Not required when using HW series nameplates See page A3-96. For more information on these options, contact your IDEC representative. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-73 Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Assembled) Mounting Part Numbers: 2–Position LED/Incandescent Selector Switches Plastic Bezel Operator Position Type Part Number Contact Switches & Pilot Devices A3 1NO1NC 1 2 O X X O 2NO 1 2 O O X X 2NO2NC 1 2 3 4 O X O X X O X O L Maintained R L Full Voltage Transformer 120V 240V 480V Full Voltage Transformer 120V 240V 480V Full Voltage Transformer 120V 240V 480V R Part Number Spring Return From Right L R HW➄F-2F11Q➃-➁-➂ HW➄F-21F11Q➃-➁-➂ HW➄F-2F11H2➃-➁ HW➄F-2F11M4➃-➁ HW➄F-2F11T8➃-➁ HW➄F-21F11H2➃-➁ HW➄F-21F11M4➃-➁ HW➄F-21F11T8➃-➁ HW➄F-2F20Q➃-➁-➂ HW➄F-21F20Q➃-➁-➂ HW➄F-2F20H2➃-➁ HW➄F-2F20M4➃-➁ HW➄F-2F20T8➃-➁ HW➄F-21F20H2➃-➁ HW➄F-21F20M4➃-➁ HW➄F-21F20T8➃-➁ HW➄F-2F22Q➃-➁-➂ HW➄F-21F22Q➃-➁-➂ HW➄F-2F22H2➃-➁ HW➄F-2F22M4➃-➁ HW➄F-2F22T8➃-➁ HW➄F-21F22H2➃-➁ HW➄F-21F22M4➃-➁ HW➄F-21F22T8➃-➁ 1. In place of ➁ specify the Lens/LED color code. 2. In place of ➂ specify the Full Voltage code. 3. In place of ➃ specify Lamp Type code. 4. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table below). 5. For nameplates, see page A3-96. 6. For partial and sub-assembly part numbers, see pages A3-76 and A3-77. 7. Mounting refers to contact location on operator. See page A3-82. ➁ Lens/LED Color Code ➂ Full Voltage Code ➃ Lamp Type Code ➄ Bezel Type Type Code Color Code Voltage Code Lamp Code Amber A 6V AC/DC 6V Incandescent Blank Plastic 1 Green G 12V AC/DC 12V LED D Metal 4 Red R 24V AC/DC 24V Blue S W 120V AC (LED only) 120 V White Yellow Y 240V AC (LED only) 240 V A3-74 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Assembled) con’t Part Numbers: 3–Position LED/Incandescent Selector Switches 1NO1NC 1 2 O O X O X X 2NO 1 2 X O O O O X 2NC 1 2 O X X X X O 1 2 3 4 X O O X O O X X O X X O Full Voltage 2NO2NC 1 2 3 4 X O X O O O O O O X O X Full Voltage 4NO 1 2 3 4 O X O X X X X X X O X O Full Voltage 4NC L C R Part Number Part Number Part Number Part Number Maintained Spring Return From Right Spring Return From Left Spring Return Two-Way C L Full Voltage Transformer 120V 240V 480V Full Voltage Transformer 120V 240V 480V Full Voltage Transformer Transformer Transformer Transformer 120V 240V 480V 120V 240V 480V 120V 240V 480V 120V 240V 480V C L R HW➄F-3F11Q➃-➁-➂ HW➄F-3F11H2➃-➁ HW➄F-3F11M4➃-➁ HW➄F-3F11T8➃-➁ HW➄F-3F20Q➃-➁-➂ HW➄F-3F20H2➃-➁ HW➄F-3F20M4➃-➁ HW➄F-3F20T8➃-➁ HW➄F-3F02Q➃-➁-➂ HW➄F-3F02H2➃-➁ HW➄F-3F02M4➃-➁ HW➄F-3F02T8➃-➁ HW➄F-3F22Q➃-➁-➂ HW➄F-3F22H2➃-➁ HW➄F-3F22M4➃-➁ HW➄F-3F22T8➃-➁ HW➄F-3F40Q➃-➁-➂ HW➄F-3F40H2➃-➁ HW➄F-3F40M4➃-➁ HW➄F-3F40T8➃-➁ HW➄F-3F04Q➃-➁-➂ HW➄F-3F04H2➃-➁ HW➄F-3F04M4➃-➁ HW➄F-3F04T8➃-➁ C C R HW➄F-31F11Q➃-➁-➂ HW➄F-31F11H2➃-➁ HW➄F-31F11M4➃-➁ HW➄F-31F11T8➃-➁ HW➄F-31F20Q➃-➁-➂ HW➄F-31F20H2➃-➁ HW➄F-31F20M4➃-➁ HW➄F-31F20T8➃-➁ HW➄F-31F02Q➃-➁-➂ HW➄F-31F02H2➃-➁ HW➄F-31F02M4➃-➁ HW➄F-31F02T8➃-➁ HW➄F-31F22Q➃-➁-➂ HW➄F-31F22H2➃-➁ HW➄F-31F22M4➃-➁ HW➄F-31F22T8➃-➁ HW➄F-31F40Q➃-➁-➂ HW➄F-31F40H2➃-➁ HW➄F-31F40M4➃-➁ HW➄F-31F40T8➃-➁ HW➄F-31F04Q➃-➁-➂ HW➄F-31F04H2➃-➁ HW➄F-31F04M4➃-➁ HW➄F-31F04T8➃-➁ L R HW➄F-32F11Q➃-➁-➂ HW➄F-32F11H2➃-➁ HW➄F-32F11M4➃-➁ HW➄F-32F11T8➃-➁ HW➄F-32F20Q➃-➁-➂ HW➄F-32F20H2➃-➁ HW➄F-32F20M4➃-➁ HW➄F-32F20T8➃-➁ HW➄F-32F02Q➃-➁-➂ HW➄F-32F02H2➃-➁ HW➄F-32F02M4➃-➁ HW➄F-32F02T8➃-➁ HW➄F-32F22Q➃-➁-➂ HW➄F-32F22H2➃-➁ HW➄F-32F22M4➃-➁ HW➄F-32F22T8➃-➁ HW➄F-32F40Q➃-➁-➂ HW➄F-32F40H2➃-➁ HW➄F-32F40M4➃-➁ HW➄F-32F40T8➃-➁ HW➄F-32F04Q➃-➁-➂ HW➄F-32F04H2➃-➁ HW➄F-32F04M4➃-➁ HW➄F-32F04T8➃-➁ L HW➄F-33F11Q➃-➁-➂ HW➄F-33F11H2➃-➁ HW➄F-33F11M4➃-➁ HW➄F-33F11T8➃-➁ HW➄F-33F20Q➃-➁-➂ HW➄F-33F20H2➃-➁ HW➄F-33F20M4➃-➁ HW➄F-33F20T8➃-➁ HW➄F-33F02Q➃-➁-➂ HW➄F-33F02H2➃-➁ HW➄F-33F02M4➃-➁ HW➄F-33F02T8➃-➁ HW➄F-33F22Q➃-➁-➂ HW➄F-33F22H2➃-➁ HW➄F-33F22M4➃-➁ HW➄F-33F22T8➃-➁ HW➄F-33F40Q➃-➁-➂ HW➄F-33F40H2➃-➁ HW➄F-33F40M4➃-➁ HW➄F-33F40T8➃-➁ HW➄F-33F04Q➃-➁-➂ HW➄F-33F04H2➃-➁ HW➄F-33F04M4➃-➁ HW➄F-33F04T8➃-➁ 1. In place of ➁ specify the Lens/LED color code. 2. In place of ➂ specify the Full Voltage code. 3. In place of ➃ specify Lamp Type code. 4. In place of ➄ enter 1 for plastic bezel or 4 for metal bezel (see table below). 5. For nameplates, see page A3-96. 6. For partial and sub-assembly part numbers, see pages A3-76 and A3-77. 7. Mounting refers to contact location on operator. See page A3-82. ➁ Lens/LED Color Code ➂ Full Voltage Code Color Code Voltage Amber A 6V AC/DC ➄ Bezel Type Type Code Lamp Code 6V Incandescent Blank Plastic 1 D Metal 4 Green G 12V AC/DC 12V Red R 24V AC/DC 24V Blue S W 120V AC (LED only) 120 V White Yellow Y 240V AC (LED only) 240 V www.idec.com ➃ Lamp Type Code Code LED USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3 R A3-75 Switches & Pilot Devices Mounting Type Contact Operator Position Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Partial-Assemblies) Contact Assembly + Lamp + Operator/Lens = Complete Part Full Voltage Models 2 pos. Part Numbers: Operators/Lens Type 3 pos. Maintained Plastic Part Numbers: Lamps Type Voltage Metal HW1F-2➁ HW4F-2➁ Spring from Right HW1F-21➁ HW4F-21➁ Maintained HW4F-3➁ HW1F-3➁ LED Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ Spring from Right HW1F-31➁ HW4F-31➁ Spring from Left HW1F-32➁ HW4F-32➁ 120V AC LSTD-H2➁ Spring from Both HW1F-33➁ HW4F-33➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Incandescent In place of ➁, specify the Lens Color Code from table below. Part Numbers: Contact Assemblies (order lamp separately) Style Contacts Part Number 1NO 2NO 1NO/1NC 1NC 2NC 1. In place of ➁, specify the LED Color Code from table below. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. HW-FL10Q0 HW-FL20Q0 HW-FL11Q0 HW-FL01Q0 HW-FL02Q0 Order lamp separately from table on right. Transformer Models 120V AC with LED 240V AC with LED 480V AC with LED 120V AC with Incandescent 240V AC with Incandescent 1NO 2NO 1NC 1NO/1NC 1NO 2NO 1NC 1NO/1NC 1NO 2NO 1NC 1NO/1NC 1NO 2NO 1NC 1NO/1NC 1NO 2NO 1NC 1NO/1NC HW-FL10H2-➁ HW-FL20H2-➁ HW-FL01H2-➁ HW-FL11H2-➁ HW-FL10M4-➁ HW-FL20M4-➁ HW-FL01M4-➁ HW-FL11M4-➁ HW-FL10T8-➁ HW-FL20T8-➁ HW-FL01T8-➁ HW-FL11T8-➁ HW-FL10H2 HW-FL20H2 HW-FL01H2 HW-FL11H2 HW-FL10M4 HW-FL20M4 HW-FL01M4 HW-FL11M4 6V LED/Lamp included with transformer sub-assembly. A3-76 www.idec.com Part Numbers: Operators/Lens Type 2 pos. Part Numbers: Contact Assemblies (lamp included) Style Contacts Part Number 3 pos. Switches & Pilot Devices A3 Maintained Plastic HW1F-2➁ Metal HW4F-2➁ Spring from Right HW1F-21➁ HW4F-21➁ Maintained HW4F-3➁ HW1F-3➁ Spring from Right HW1F-31➁ HW4F-31➁ Spring from Left HW1F-32➁ HW4F-32➁ Spring from Both HW1F-33➁ HW4F-33➁ In place of ➁, specify the Lens Color Code from table below. ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Sub-Assembled) Transformer * + Contact Blocks + Lead Holder + Adaptor + Lamp + Anti-Rotation + Operator + Illuminated = Complete Part Knob A3 2 3 Part Numbers: Contact Blocks Description Plastic Bezel Metal Bezel Maintained HW1F-2 HW4F-2 Spring return from right HW1F-21 HW4F-21 HW-F10 HW-F01 Maintained HW1F-3 HW4F-3 Spring return from right HW-F10R (early make) HW-F01R (late break) HW1F-31 HW4F-31 Spring return from left HW1F-32 HW4F-32 Two-way spring return HW-G10 HW-G01 HW1F-33 HW4F-33 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Switches & Pilot Devices * not applicable for full voltage units Part Numbers: Operators # of Appearance Description Positions Part Number 1NO 1NC Standard Fingersafe (IP20) Spring-Up Terminal Contacts Illuminated knobs must be ordered separately. Part Numbers: Illuminated Knob Appearance Description Exposed Screw Terminal Contacts Part Number Amber HW9Z-FDY-A Green HW9Z-FDY-G Red HW9Z-FDY-R Blue HW9Z-FDY-S White HW9Z-FDY-W Yellow HW9Z-FDY-Y Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Style Part Number HW-CBL Dummy Block TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HWG...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. 1. Used to mount contact blocks to operator (first pair only). Lamp holder is built-in. 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-77 Oiltight Switches & Pilot Devices ø22mm - HW Series Illuminated Selector Switches (Sub- Assembled) con’t Part Numbers: Lamps Type Voltage A3 6V AC/DC LSTD-6➁ Fingersafe LED Switches & Pilot Devices Part Numbers: Transformer Unit Style Voltage Part Number Part Number Incandescent 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 (6V secondary voltage) 12V AC/DC IS-12 DC-DC Converter 24V AC/DC IS-24 For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. For use with odd number of contacts. 120V AC 240V AC 480V AC HW-T126 HW-T246 HW-L486 110VDC HW-L16D 1. DC-DC convertor features spring-up terminals. 2. Applicable voltage range 90-140V DC. ➁ LED Color Code Part Numbers: Lamp Circuit Components Style Description Terminals Part Number Dummy Block with Full Voltage Adaptor TW-F126B TW-F246B TW-F486B Spring Up 1. In place of ➁, specify the LED Color Code from table at right. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. Lead Holder 120V AC 240V AC 480V AC HW-LH3 Fingersafe HW-DA1FB Exposed HW-DA1B Spring Up HW-GA1 Fingersafe TW-DA1FB Exposed TW-DA1B Color Code Amber A Green G Red R Blue S White W Yellow Y Part Numbers: Anti-Rotation Ring Appearance Part Number HW9Z-RL Full Voltage Adaptor For use with even number of contacts. 1. Use with notched panel cutout to prevent unit rotation. 2. Not required when using HW series nameplates See page A3-96. HW-GA1 “Dummy Block with full voltage adaptor” does not require the use of HW-LH3. A3-78 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. Step1: How many positions of the switch are needed? # of positions (2, 3, 4, 5) A3 Switches & Pilot Devices Step 2: How many contacts should there be? # of isolated contacts (maximum 6) Step 3: Fill in the Truth Table (X = closed, O = open) Knob Position 1 C o n t a c t s 2 3 4 5 1 2 3 4 5 6 Step 4: If building a 2, 4, or 5 position selector, skip this step. (2, 4, 5 position selectors have only one cam) If building a 3 position selector, determine appropriate cam as follows: Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). Repeat for all rows. Find one operator that contains all rows from above table. Record the operator cam version. Operator CAM Version (blank, S, J for 3 position) Step 5: Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right side of operator as viewed from the front of the panel. Caution: Before putting any custom selector switch into use, it should be tested using an ohmmeter. For Operator Truth Tables, see next page. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-79 Oiltight Switches & Pilot Devices ø22mm - HW Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Switches & Pilot Devices A3 Contact HW-F10 (NO) HW1S-2T HW1K-2* HW1F-2 HW-F01 (NC) HW-F10R NO-(EM) HW-F01R NC-(LB) Mounting Position 1. Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). 2. * for key removable code (see page A3-73). Operator Position Left Right L O X R O X L X O R X O L 0 X R O X L X O R X O 3 Position Selector Switches Contact HW-F10 (NO) HW1S-3T HW1K-3* HW1F-3 HW-F01 (NC) HW-F10R NO-(EM) HW-F01R NC-(LB) Contact HW-F10 (NO) HW1S-3ST HW1K-3S* HW-F01 (NC) HW-F10R NO-(EM) HW-F01R NC-(LB) Contact HW-F10 (NO) HW1S-3JT HW1K-3J* HW-F01 (NC) HW-F10R NO-(EM) HW-F01R NC-(LB) A3-80 Mounting Position Operator Position Left Center Right L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O Operator Position Mounting Position Left L X O O R O O X L O O X R X O O L X X O R O X X L O X X R X X O Center Right Operator Position Mounting Position Left L X O R O O X L O X O R O X O L X O X R X O X L O X X R X X O www.idec.com Center Right O 1. HW1S-3T is identified by white plungers on the operator. 2. Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). 3. * for key removable code (see page A3-73). 1. HW1S-3ST is identified by red plungers on the operator. 2. Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). 3. * for key removable code (see page A3-73). 1. HW1S-3JT is identified by black plungers on the operator. 2. Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). 3. * for key removable code (see page A3-73). USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Operator Truth Tables con’t 4 Position Selector Switches Contact HW-F01 (NC) HW1S-4T HW-F10R NO-(EM) HW-F01R NC-(LB) 1 2 3 4 L X O O O R O O O X L O O X O R O X O O L X X O X R X O X X L O X X X R X X X O A3 Switches & Pilot Devices HW-F10 (NO) Operator Position Mounting Position 5 Position Selector Switches Contact HW-F10 (NO) HW-F01 (NC) HW1S-5T HW-F10R NO-(EM) HW-F01R NC-(LB) www.idec.com Operator Position Mounting Position 1 2 3 4 5 L X O O O O R O O O O X L O O O X O R O X O O O L X X X O X R X O X X X L O X X X X R X X X X O Mounting position indicates which side of operator each contact should be mounted (as viewed from the front of the panel). USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-81 Oiltight Switches & Pilot Devices ø22mm - HW Series Custom Selector Switch Building Examples Example 1: 3 Position, Maintained Selector Switch with 3 Contacts A3 Determine which operator is capable of producing all the desired contact actions. Knob Position Switches & Pilot Devices Left Operator Center Right HW1S-3T HW1S-3ST HW1S-3JT Contact 1 O O X Possible with HW-F10 mounted on right Possible with HW-F10 mounted on right Possible with HW-F10 mounted on right Contact 2 0 X O Not possible Not possible Possible with HW-F01 mounted on left or right Contact 3 X O O Possible with HW-F10 mounted on left Possible with HW-F10 mounted on left Possible with HW-F10 mounted on left The only operator in this example that will produce all the desired contact actions is HW1S-3JT. Assemble as follows: Right TW-DB (dummy block) Left HW-F10 HW-F01 HW-F10 HW1S-3JT Example 2: 3 Position, Maintained Selector Switch with 2 Contacts Determine which operator is capable of producing all the desired contact actions. Knob Position Left Operator Center Right HW1S-3T HW1S-3ST HW1S-3JT Contact 1 O O X Possible with HW-F10 mounted on right Possible with HW-F10 mounted on right Possible with HW-F10 mounted on right Contact 2 0 X X Possible with HW-F01 mounted on left Possible with HW-F10R mounted on right or HW-F01R mounted on left Not possible This arrangement is possible with either the HW1S-3T or HW1S-3ST operator. It is preferred to use the HW1S-3T as this requires only the standard contacts (HWF10 and HW-F01 and not the early make (HW-F10R) or late break (HW-F01R) contacts. Assemble as follows: Right Left HW-F10 HW-F01 HW1S-3T A3-82 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Custom Selector Switch Building Examples con’t Example 3: 4 Position Selector Switch with 4 Contacts Determine where the contact will be mounted. Knob Position A3 Operator 2 3 4 HW1S-4T Contact 1 O X O O HW-F01 mounted on right Contact 2 0 O X O HW-F01 mounted on left Contact 3 O O O X HW-F10 mounted on right Contact 4 O X X X HW-F01R mounted on left Switches & Pilot Devices 1 Assemble as follows: Right HW-F01 Left HW-F10 HW-F01 HW-F01R HW1S-4T Example 4: 5 Position Selector Switch with 4 Contacts Determine where the contact will be mounted. Knob Position 1 Operator 2 3 4 5 HW1S-5T Contact 1 O X O O O HW-F01 mounted on right Contact 2 O O O X O HW-F01 mounted on left Contact 3 O O O O X HW-F10 mounted on right Contact 4 X O X X X HW-F10R mounted on right Assembled as follows: Right HW-F01 Left HW-F10 HW-F10R TW-DB (dummy block) TW-DB (dummy block) HW-F01 HW1S-5T www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-83 ø22mm - HW Series Oiltight Switches & Pilot Devices Dual Pushbutton Switches Switches & Pilot Devices A3 Two pushbuttons and a pilot light are integrated into one spacesaving ø22 mm control unit. • Momentary and interlock types are available for pushbuttons. Interlock type prevents both buttons from being pressed at the same time. • Pilot lights are available in full voltage and transformer types illuminated with LED or incandescent lamps. • IP40 protection, IP65 when using silicon cover. • UL Listed, CSA approved, and EN compliant Applications: • Ideal for use as power switches and start/stop switches (available with I/ON and O/OFF markings on the buttons and a pilot light in the center). • Interlock type prevents two pushbuttons from being pressed at the same time. Dual Pushbutton Switches (Assembled) Part Numbers: Operation Type Button Style Contact Arrangement Top Bottom Button Button 1NO Flush (top) Flush (bottom) Momentary Flush (top) Extended (bottom) Flush (top) Flush (bottom) Interlock* Flush (top) Extended (bottom) 1NC Part Number ➃ Button Color Code ➄ Legend Code HW7D-B11F1001-➃➄ 1NO 1NO HW7D-B11F1010-➃➄ 1NO-1NC 1NO-1NC HW7D-B11F1111-➃➄ 2NO 2NC HW7D-B11F2002-➃➄ 2NO 2NO HW7D-B11F2020-➃➄ 1NO 1NC HW7D-B12F1001-➃➄ 1NO 1NO HW7D-B12F1010-➃➄ 1NO-1NC 1NO-1NC HW7D-B12F1111-➃➄ 2NO 2NC HW7D-B12F2002-➃➄ 2NO 2NO HW7D-B12F2020-➃➄ 1NO 1NC HW7D-B21F1001-➃➄ 1NO 1NO HW7D-B21F1010-➃➄ 1NO-1NC 1NO-1NC HW7D-B21F1111-➃➄ 2NO 2NC HW7D-B21F2002-➃➄ 2NO 2NO HW7D-B21F2020-➃➄ 1NO 1NC HW7D-B22F1001-➃➄ 1NO 1NO HW7D-B22F1010-➃➄ 1NO-1NC 1NO-1NC HW7D-B22F1111-➃➄ 2NO 2NC HW7D-B22F2002-➃➄ 2NO 2NO HW7D-B22F2020-➃➄ GR: Green (top) Red (bottom) WB: White (top) Black (bottom) Blank:Without legend 1:I/ON (top) O/OFF (bottom) 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. A3-84 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Part Numbers, con’t Part Numbers: With Center Pilot Light Operation Type Button Style Pilot Light Type Full Voltage Momentary Transformer Full Voltage Flush (Top) Extended (Bottom) Transformer Flush (top) Flush (bottom) Full Voltage Flush (Top) Flush (Bottom) Flush (top) Extended (bottom) Interlock* Transformer Full Voltage Flush (Top) Extended (Bottom) Transformer Bottom Button Part Number 1NO 1NC HW7D-L11F1001➁➂-➃➄ 1NO 1NO HW7D-L11F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L11F1111➁➂-➃➄ 2NO 2NC HW7D-L11F2002➁➂-➃➄ 2NO 2NO HW7D-L11F2020➁➂-➃➄ 1NO 1NC HW7D-L11F1001➁➂-➃➄ 1NO 1NO HW7D-L11F1010➁➂➃➄ 1NO-1NC 1NO-1NC HW7D-L11F1111➁➂-➃➄ 2NO 2NC HW7D-L11F2002➁➂-➃➄ 2NO 2NO HW7D-L11F2020➁➂-➃➄ 1NO 1NC HW7D-L12F1001➁➂-➃➄ 1NO 1NO HW7D-L12F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L12F1111➁➂-➃➄ 2NO 2NC HW7D-L12F2002➁➂-➃➄ 2NO 2NO HW7D-L12F2020➁➂-➃➄ 1NO 1NC HW7D-L12F1001➁➂-➃➄ 1NO 1NO HW7D-L12F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L12F1111➁➂-➃➄ 2NO 2NC HW7D-L12F2002➁➂-➃➄ 2NO 2NO HW7D-L12F2020➁➂-➃➄ 1NO 1NC HW7D-L21F1001➁➂-➃➄ 1NO 1NO HW7D-L21F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L21F1111➁➂-➃➄ 2NO 2NC HW7D-L21F2002➁➂-➃➄ 2NO 2NO HW7D-L21F2020➁➂-➃➄ 1NO 1NC HW7D-L21F1001➁➂-➃➄ 1NO 1NO HW7D-L21F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L21F1111➁➂-➃➄ 2NO 2NC HW7D-L21F2002➁➂-➃➄ 2NO 2NO HW7D-L21F2020➁➂-➃➄ 1NO 1NC HW7D-L22F1001➁➂-➃➄ 1NO 1NO HW7D-L22F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L22F1111➁➂-➃➄ 2NO 2NC HW7D-L22F2002➁➂-➃➄ 2NO 2NO HW7D-L22F2020➁➂-➃➄ 1NO 1NC HW7D-L22F1001➁➂-➃➄ 1NO 1NO HW7D-L22F1010➁➂-➃➄ 1NO-1NC 1NO-1NC HW7D-L22F1111➁➂-➃➄ 2NO 2NC HW7D-L22F2002➁➂-➃➄ 2NO 2NO HW7D-L22F2020➁➂-➃➄ 1. *Interlock type prevents both top and bottom buttons from being pressed simultaneously. 2. Clear silicon rubber cover part number HW9Z-D7D. www.idec.com ➁Pilot Light Illumination Type and Voltage Code Full Voltage Voltage Code 6V AC/DC, LED Q2 12V AC/DC, LED Q3 24V AC/DC, LED Q4 120V AC, LED Q8 6V AC/DC, Incandescent Q5* 12V AC/DC, Incandescent Q6* 24V AC/DC, Incandescent Q7* Step-Down Transformer (6V Secondary Lamp Voltage) Voltage Code 120V AC, LED H22 240V AC, LED M42 480V AC, LED T82 120V AC, Incandescent H25* 240V AC, Incandescent M45* 480V AC, Incandescent T85* * Only available for White Lens Pilot Lamp. ➂Pilot Lamp Color Code Color Code Amber A* Green G* Red R* Blue S* White W Yellow Y* * Only available for LED Type illumination. ➃Pushbutton Color Code Color Code Top Green Bottom Red Top White Bottom Black GR WB ➄Engraving Codes Engraving Code No Engraving I/ON Top O/OFF Bottom USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Blank 1 A3-85 A3 Switches & Pilot Devices Flush (Top) Flush (Bottom) Top Button Oiltight Switches & Pilot Devices ø22mm - HW Series Contact Arrangement Chart Contact Arrangement Top Button Switches & Pilot Devices A3 Bottom Button Contact Code Contact Block Mounting Type Position Top Button Normal Push Bottom Button Normal 1 NO X 2 NO 1 NO X 1NO 1NC 1001 2 NC X 1 NC X 1NC 1NO 0110 2 NO 1 NC X 1NC 1NC 0101 2 NC X 1 NO X 2 NO 1NO 2NO 1020 3 Dummy 4 NO 1 NO X 2 NO 1NO 1NO-1NC 1011 3 Dummy 4 NC X 1 NO X 2 NC X 1NO 2NC 1002 3 Dummy 4 NC X 1 NC X 2 NO 1NC 2NO 0120 3 Dummy 4 NO 1 NC X 2 NO 1NC 1NO-1NC 0111 3 Dummy 4 NC X 1 NC X 2 NC X 1NC 2NC 0102 3 Dummy 4 NC X 1 NO X 2 NO 2NO 1NO 2010 3 NO X 4 Dummy 1 NO X 2 NC X 2NO 1NC 2001 3 NO X 4 Dummy 1 NO X 2 NO 1NO-1NC 1NO 1110 3 NC X 4 Dummy 1 NO X 2 NO X 1NO-1NC 1NC 1101 3 NC X 4 Dummy 1 NC X 2 NO 2NC 1NO 0210 3 NC X 4 Dummy 1. Transformers can have two or four contact blocks only. 2. Contact blocks 1 and 3 are actuated by the top button. Contact blocks 2 and 4 are actuated by the bottom button. 1NO A3-86 1NO 1010 www.idec.com Push X X X X X X X X X X X USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Contact Arrangement Chart con’t Contact Arrangement Top Button Bottom Button 1NC 2NO 2NO 2NO 1NO-1NC 2NO 2NC 1NO-1NC 2NO 1NO-1NC 1NO-1NC 1NO-1NC 2NC 2NC 2NO 2NC 1NO-1NC 2NC 2NC Contact Code 0201 2020 2011 2002 1120 1111 1102 0220 0211 0202 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 NC NC NC Dummy NO NO NO NO NO NO NO NC NO NC NO NC NO NO NC NO NO NO NC NC NO NC NC NC NC NO NC NO NC NO NC NC NC NC NC NC Top Button Normal Push Bottom Button Normal Push A3 X X Switches & Pilot Devices 2NC Contact Block Mounting Type Position X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X Contact Block Mounting Position Example 4 3 2 1 With Pilot Light (transformer type) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-87 Oiltight Switches & Pilot Devices ø22mm - HW Series Dual Pushbutton Switches (Sub-Assembled) Contact Blocks + Mounting Adaptor + Operator + Lens = Complete Part Part Number Flush (top) Flush (bottom) HW7D-011➃-➄ Flush (top) Extended (bottom) HW7D-012➃-➄ Flush (top) Flush (bottom) HW7D-021➃-➄ Flush (top) Extended (bottom) HW7D-022➃-➄ Interlock Flush Extended Flush Flush Momentary Part Numbers: Operators Style Type Button Style ➃Pushbutton Color Code Color Top Bottom Top Bottom ➄Engraving Codes Code Green Red White Black GR WB Engraving Code No Engraving I/ON Top O/OFF Bottom Blank 1 Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Appearance Part Number Non-Illuminated HW-CB2C Illuminated (with Pilot Light) HW-CBL Part Numbers: Lamps/Lens Type Voltage Lamps LED Incandescent Non-Illuminated 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC 6.3V AC/DC 12V AC/DC 24V AC/DC 30V AC/DC 1.Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. Illuminated Part Numbers: Contact Blocks Description LSTD-6➁ LSTD-1➁ LSTD-2➁ LSTD-H2➁ LSTD-M4➁ IS-6 IS-12 IS-24 IS-30 HW9Z-B7B HW9Z-L7W Part Number 1NO 1NC Standard HW-F10 HW-F01 Fingersafe (IP20) HW-F10R (early make) HW-F01R (late break) Spring-Up HW-G10 HW-G01 Terminal HW-G10R (early make) HW-G01R (late break) Contacts HW-G10-MAU (gold contacts) HW-G01-MAU (gold contacts) Exposed Screw HW-C10 HW-C01 Terminal Contacts HW-C10R (early make) HW-C01R (late break) Dummy Block TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. (excep unibody) 2. Assembled units with spring-up terminals (HW-G...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-component 4. All contacts (including exposed screw) are UL, CSA, and IEC compliant and carry the CE mark. Part Numbers: Lamp Circuit Components Style Description Terminals Part Number For use with HW-CBL on all illuminated pushbutton units. One required for each deck (pair) of contacts. Fingersafe Exposed For use with odd number of contacts. Spring Up Lead Holder Dummy Block with Full Voltage Adaptor Full Voltage Adaptor For use with even number of contacts. 120VAC 240VAC 480VAC 120V 240V 480V 120V 240V 480V 110VDC Transformer Unit Part Number Lens Switches & Pilot Devices A3 (6V secondary voltage) DC-DC Converter HW-LH3 HW-DA1FB HW-DA1B HW-GA1 Fingersafe TW-DA1FB Exposed TW-DA1B Fingersafe Spring Up Exposed TW-F126B TW-F246B TW-F486B HW-T126 HW-T246 HW-L486 TW-T126B TW-T246B TW-T486B HW-L16D HW-GA1 “Dummy Block with full voltage adaptor” does not require the use of HW-LH3. Part Numbers: Anti-Rotation Ring Appearance Part Number HW9Z-RL Use with notched panel cutout to prevent unit rotation. LED Color Code Color Code Color Code Amber A Blue S Green G White W Red R Yellow Y 1. In place of ➁, specify the LED Color Code from table on right. 2. The LED contains a current-limiting resistor and reverse polarity protection diodes. A3-88 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Mono Lever Switches (Assembled) Part Numbers: Mono Lever Switches No. of Description Part Number Positions A3 HW1M-F1010-20 HW1M-F2020-20 HW1M-F0202-20 HW1M Standard Lever HW1M-F0101-40 Part Number Guide ➁ ➀ HW1M- L F 0 up Type 0 1 right down left Lever Action Description Standard ➀ Type ➁ Lever Action – 1 Interlocking mechanism prevents inadvertent activation 1 Spring 2 Blocked 0 HW1M-F2222-22N9 Circuit Number (blank) Maintained HW1M-F1111-22N9 4 HW1M-LF1010-20 Remarks L HW1M-F0202-40 ➂ 20 Code Interlocking Switches & Pilot Devices HW1M-F0101-20 2 HW1M-LF2020-20 HW1M-LF0101-20 2 HW1M-LF0202-20 HW1M-L Interlocking Lever HW1M-LF0101-40 HW1M-LF0202-40 Fill in desired action for each position: Up/Right/Down/Left HW1M-LF1111-22N9 4 HW1M-LF2222-22N9 20 ➂ Circuit Number See Circuit Diagrams below 40 22N9 Circuit Diagrams 2 Position Left/Right Contact Circuit Mounting Number No. 20 40 2 Position Up/Down Contact Circuit Mounting Number No. Position 1 HW-F10 Left Center Right X 0 0 2 HW-F10 0 0 X 1 HW-F10 X 0 0 2 HW-F10 0 0 X 3 HW-F10 X 0 0 4 HW-F10 0 0 X 20 40 3 Position Circuit Number 30 Position Down Center 1 HW-F10 X 2 HW-F10 1 HW-F10 2 HW-F10 3 HW-F10 4 HW-F10 0 Up 0 0 0 0 X X 0 0 0 0 X X 0 0 0 X 4 Position Contact Mounting No. Position Down Left Center Up Right 1 HW-F01 0 O 0 0 X 2 HW-F01 X 0 0 O 0 3 HW-F10 0 X 0 0 O Circuit Number 22N9 Contact Mounting No. Position Down Left Center Up Right 1 HW-F01 0 O 0 0 X 2 HW-F01 X 0 0 O 0 3 HW-F10 0 X 0 0 O 4 HW-F10 O 0 0 X 0 Other circuit arrangements available, contact IDEC for details. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-89 Oiltight Switches & Pilot Devices ø22mm - HW Series Mono Lever Switches (Sub- Assembled) Contact Blocks + Mounting Adaptor + Anti-Rotation Ring + Operator = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators Appearance # of Positions Standard 2 4 Interlocking 2 4 Description Part Number Maintained Up/Down Spring return Up/Down Maintained Left/Right Spring return Left/Right Maintained, 4 position Spring return, 4 position Maintained Up/Down Spring return Up/Down Maintained Left/Right Spring return Left/Right Maintained, 4 position HW1M-1010 HW1M-2020 HW1M-0101 HW1M-0202 HW1M-1111 HW1M-2222 HW1M-L1010 HW1M-L2020 HW1M-L0101 HW1M-L0202 HW1M-L1111 Spring return, 4 position HW1M-L2222 Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Appearance Part Number Part Numbers: Contact Blocks Description Part Number 1NO 1NC Standard Fingersafe (IP20) HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. Part Numbers: Anti-Rotation Ring Appearance Part Number Part Numbers: Replacement Parts Item Part Number Black Cap HW9Z-CPM Boot HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Spring-Up Terminal Contacts Exposed Screw Terminal Contacts HW9Z-RL 1. Use with notched panel cutout to prevent unit rotation. 2. Not required when using HW series nameplates See page A3-96. HW-F10 Dummy Block TW-DB 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HWG...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. HW9Z-BLM (fits standard type operator only) A3-90 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Pushbutton Selectors (Assembled) Part Numbers: 2–Position Pushbutton Selectors Operator Position Part Number Normal Depressed 1 HW-F10 2 HW-F10 0 0 X 0 0 0 0 X HW1R-2DF20-① 1 HW-F10 0 0 X X X 0 0 X 0 0 X X 0 X X 0 HW1R-2DF22N1-① 0 0 0 X X 0 0 X 0 0 X 0 0 X X 0 HW1R-2EF22N1-① 0 0 0 X 0 X 0 0 0 0 X 0 X 0 0 0 HW1R-2FF22N1-① 2NO-2NC 23 HW-F10 HW-F01 4 HW-F01 1 HW-F10 2NO-2NC 23 HW-F10 HW-F01 4 HW-F01 1 HW-F10 2NO-2NC 23 HW-F10 HW-F01 4 HW-F01 A3 Right Depressed Left Switches & Pilot Devices 2NO Mounting Normal Contacts 1. Available only with momentary pushbutton and maintained selector. 2. In place of ➀, specify the button color code from table below 3. Other contact arrangements available. Contact IDEC for details. 4. All assembled parts use flush buttons. 5. Normal position refers to the button flush with the selector ring. 6. Depressed position refers to the button being pushed in. ① Button Color Code Color www.idec.com Code Black B Green G Red R Blue S White W Yellow Y Grey N USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-91 Oiltight Switches & Pilot Devices ø22mm - HW Series Pushbutton Selectors (Partial-Assemblies) Contact Assembly + Operator/Button = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators Appearance Description Part Number Cam D HW1R-2D-① Cam E HW1R-2E-① Cam F HW1R-2F-① In place of ① specify Button Color Code. Part Numbers: Contact Assemblies Contacts Style Standard Fingersafe Contacts Spring Up Terminal Contacts Part Number 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CBF10 HW-CBF01 HW-CBF11 HW-CBF20 HW-CBF02 HW-CBF22 1NO 1NC 1NO/1NC 2NO 2NC 2NO/2NC HW-CB10 HW-CB01 HW-CB11 HW-CB20 HW-CB02 HW-CB22 ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N A3-92 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Pushbutton Selectors (Sub-Assembled) Contact Blocks + Contact Mounting Adaptor + Anti-Rotation Ring + Operator + Button = Complete Part A3 Cam D Part Numbers: Buttons Description Part Numbers: Contact Blocks Description Part Number 1NO HW1R-2D Cam E HW1R-2E Cam F HW1R-2F Cam N HW1R-2N Part Number 1NC Standard Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) HW-G10 HW-G01 HW-G10R (early make) HW-G01R (late break) HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) Spring-Up Terminal Contacts Round Flush HW1A-B1-① In place of ① specify Button Color Code. Switches & Pilot Devices Part Numbers: Operators Appearance Description Part Number Exposed Screw Terminal Contacts Part Numbers: Anti-Rotation Ring Appearance Part Number Dummy Block HW9Z-RL TW-DB 1. Use with notched panel cutout to prevent unit rotation. 2. Not required when using HW series nameplates See page A3-96. 1. All assembled part numbers in catalog include standard (HW-F...) contacts. 2. Assembled units with spring-up terminals (HWG...) can be ordered by removing an “F” from the part number (Ex. HW1B-M1F11-R becomes HW1B-M111-R). 3. Units with exposed screw terminals (HW-C...) must be ordered as sub-components. Part Numbers: Contact Block Mounting Adaptor (safety lever lock included) Appearance Part Number HW-CB2C 1. Used to mount contact blocks to operator (first pair only). 2. IDEC strongly recommends using the safety lever lock (included) to prevent heavy vibration or maintenance personnel from unlocking contacts. www.idec.com ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y Grey N USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-93 Oiltight Switches & Pilot Devices ø22mm - HW Series Operator Truth Tables HW Pushbutton Selector Switches - Cam D Operator Position Switches & Pilot Devices A3 Contact Mounting Position Left Button Free Right Button Free Button Pressed Left O Button Pressed X O O Right O O O X HW-F10 (NO) Left X O X X Right X X X O HW-F01 (NC) Left O X O O Right O O O X Left X O X X Right X X X O HW-F10R (NO-EM) HW-F01R (NC-LB) HW Pushbutton Selector Switches - Cam E Operator Position Contact Mounting Position Left Button Free Right Button Free Button Pressed Left O Button Pressed X O O Right O O O X Left O O X X Right X X O O Left X X O O Right O O X X Left X O X X Right X X X O HW-F10 (NO) HW-F01 (NC) HW-F10R (NO-EM) HW-F01R (NC-LB) HW Pushbutton Selector Switches - Cam F Operator Position Contact Mounting Position Left Button Free Right Button Pressed Button Free Button Pressed Left O O O X Right O X O O Left O O X O Right X O O O X HW-F10 (NO) HW-F01 (NC) Left X X O Right O X X X Left X X X O Right X O X X HW-F10R (NO-EM) HW-F01R (NC-LB) HW Pushbutton Selector Switches - Cam N Operator Position Contact Mounting Position Left Left Button Free O Right Button Pressed Button Free Button Pressed X O X HW-F10 (NO) Right O X O X Left O O X O Right X O O O Left X X O X Right O X X X Left X O X O Right X O X O HW-F01 (NC) HW-F10R (NO-EM) HW-F01R (NC-LB) A3-94 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Contactor Reset Button Part Numbers: Reset Buttons (Assembled) Appearance (Blank) Plastic Bezel Metal Bezel HW1B-M1RS-①T HW4B-M1RS-①T HW4B-M1RS-①T-ENG-R 1. In place of ① specify Button Color Code. 2. 5.1” (130mm) overall length. 3. 16mm flat base for easy alignment Color Code Black B Green G Grey N Red R Blue S White W Yellow Y Sub-Assemblies Rod Part Numbers: Button Appearance + Operator Part Number + Button = Part Numbers: Rod Appearance Complete Part Part Number HW9Z-RS-TK2141 HW1A-B1-① In place of ① specify Button Color Code from table. ① Button Color Code Color Part Numbers: Operator Appearance Plastic HW1B-MO www.idec.com Metal HW4B-MO Code Black B Green G Grey N Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-95 A3 Switches & Pilot Devices HW1B-M1RS-①T-ENG-R Engraved “R” ① Button Color Code Oiltight Switches & Pilot Devices ø22mm - HW Series Nameplates — HW Series HWAQ–Black Plastic A3 29mm ON HWAV–Yellow Plastic ERGENCY EM 45mm Ø 60mm 30mm 30mm Switches & Pilot Devices 29mm OFF HWAS–Black Plastic STOP 45mm Part Numbers: Nameplates HWAM–Black Plastic STOP 14.5mm Part Number Part Number Part Number Part Number Nameplate (blank engraving plate included) HWAM-OB HWAQ-OB HWAS-OB HWAV-O Nameplate (engraved) HWAM-➀ HWAQ-➀ HWAS-➀ HWAV-27* HWAV5-27† Additional Insert (blank) HWNP-O HWNP-O HWNP Dimensions 12mm Additional Insert (engraved) HWNP-➀ HWNP-➀ 27mm 1. In place of ➀, insert either the standard legend code from table below or custom engraving delimited by “ “. 2. Standard engravings are available at no charge. 3. * HWAV-27 comes engraved “Emergency Stop” as shown in drawing. 4. † HWAV5-27 for 80mm diameter jumbo mushroom comes engraved “Emergency Stop” as shown in drawing. Standard Legend Codes Pushbuttons Legend AUTO CLOSE DOWN EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON Code 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 Legend OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP TEST UP I (Int’l On) O (Int’l Off) EMO Pushbuttons/Selector Switches Code 116 117 118 119 120 121 122 123 125 126 127 150 151 152 Legend Code AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN OI (Int’l OFF ON) Selector Switches Code Legend Code 216 217 218 219 220 221 222 223 250 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. To order engraved nameplates, add legend code to nameplate part number. 2. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 3. Nameplates with standard legends are the same list price as blank nameplates. 4. Nameplates have built-in anti-rotation feature for use with notched panel cut-outs. Additional anti-rotation ring (HW9Z-RL) is not necessary. A3-96 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Nameplates Order Form — HW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: IDEC Rep/Distributor Contact: Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: Fax & Email IDEC Rep/Distributor Fax & Email A3 Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) 1/8” Letter Size 9 characters max (for 1/8” size letters) Sample Letter Sizes 7/64” Letters: A B C D 1/8” Letters: A B C D Qty 1 2 3 4 5 6 7 8 9 10 11 HWAQ Nameplate Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) 1/8” Letter Size 9 characters max (for 1/8” size letters) Sample Letter Sizes 7/64” Letters: A B C D 1/8” Letters: Qty 1 2 3 4 5 6 7 ABCD 8 9 10 11 HWAS Nameplate Engraving Location A Step 1. Choose Letter Size - 1/8” or 3/32”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 14 characters. 3/32” Letter Size 1/8” Letter Size 20 characters maximum (for 3/32” size letters) 14 characters maximum (for 1/8” size letters) Engraving Location B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Specify Quantity. Enter the number of nameplates desired in box on the right. www.idec.com Qty Step 3. Specify Location. Enter the location of engraving (A or B), in box on the right. Sample Letter Sizes 3/32” Letters: A B C D 1/8” Letters: A B C D Location USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-97 Switches & Pilot Devices HWAM Nameplate Oiltight Switches & Pilot Devices ø22mm - HW Series Accessories — HW Series Appearance Description/Usage Part Number Locking Ring Wrench Metallic tool used to tighten the plastic locking ring when installing the HW series unit in a panel MW9Z-T1 Lamp/LED Removal Tool Rubber tool makes lamp/LED removal easier. OR-55 Anti-Rotation Ring Prevents rotation of switches in panel. (included with all assembled switches) Switches & Pilot Devices A3 Rubber Mounting Hole Plug Metallic Mounting Hole Plug for notched panel cutout (standard) HW9Z-RL for round panel cutout LW9Z-L Black rubber plug fills unused mounting holes in panel. OB-31 For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum LW9Z-BM Degree of protection: IP66 Barrier To prevent contact between adjacent lead wires when control units are tightly mounted HW-VL1 Used to cover and protect pushbuttons Flush Pushbuttons Operating temperature: –50 to +60°C Extended Pushbuttons OC-32 Plastic hinged cover to protect pushbuttons or selector switches. (Not intended for E-Stops) HW9Z-KL1 OC-31 Pushbutton Clear Boot Padlock Cover Degree of protection: IP65 Tab Terminal Adapter Tab #250 (6.35 x 0.8mm): Single tab TW-FA1 Adaptor (22mm to 30mm) Used to mount round HW series control unit (except Jumbo Mushroom, unibody, and square units) into a 30mm panel cut-out. (includes both pieces) HW9Z-A30 Replacement Safety Lever Lock Used to prevent contact mounting lever from moving due to heavy vibration or panel maintenance. (included with all Contact Block Mounting Adaptors) HWLS-TK1971 Reset Rod for Contactors Overload 5” rod used with HW1B-M0. See Contactors Section D for more information. HW9Z-RS-TK2141 Replacement Operator Washer Provided with operator. Insert between bezel and locking ring. HWM-WASHER Replacement Locking Ring Plastic locking nut comes with all HW operators & assemblies. Standard (plastic) HW9Z-LN Optional (metal) HW9Z-LNM Switch Cover (Square) Used only with round or square flush pushbuttons. HW9Z-K1 (spring return) HW9Z-K11 (maintained cover) Replacement Keys Pair of Keys (#231) HW9Z-SKP A3-98 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices Appearance Replacement Lens ø22mm - HW Series Description/Usage HW Illuminated Unibody Replacement Lens Replacement Jumbo Dome Lens Part Number HWLV-LENSR A3 HW1A-P5① ① = (A, G, R, S, W, Y) Replacement Jumbo Diffusing Lens HW9Z-PP5C Replacement LED Lamps for HW Jumbo Dome Replacement LED Lamp LSTDB-2① Rubber Cover for Dual Pushbuttons Clear Silicon rubber cover HW9Z-D7D Barrier for Dual Pushbuttons Plastic barrier. Used when mounting the HW7 units on 30mm horizontal centers, to prevent possible interconnections between adjoining terminals. HW-VG1 www.idec.com Switches & Pilot Devices Polycarbonate Replacement Lens ① = (A, G, R, S, W, Y) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-99 Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions — HW Series Non-Illuminated Pushbuttons Panel Thickness 0.8mm to 6.mm * 29mm * Round: 23.6mm * Square: 24.8mm * D1 D1 0.5mm 50.2mm 32mm D2 70.2mm 40mm 29mm 13mm Square Round D1 D1 32mm D3 m ck 40mm 29.6mm 40.4mm 25mm 29 m Lo D1 = 13mm D2 = 19mm D3 = 23.2mm D1 D3 30mm Monolever 0.21" (8mm) 24 deg. 0.90" (23mm) 1.18" (30mm) 2.83" (72mm) Pilot Lights Panel Thickness 0.8mm to 6.0mm m Gasket M3.5 Terminal Screws 29 m Locking Ring 29.6mm 5mm 44.7mm 7mm M3.5 Terminal Screws 24mm Switches & Pilot Devices A3 Gasket Locking Ring M3.5 Terminal Screws 72.1mm 29.6mm 7mm 17.5mm A3-100 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Jumbo Mushroom Pushbutton HW1B-M5 HW1B-V5 Ø2.36in.(Ø60.0mm) 2.36" (60mm) A3 Illuminated Pushbuttons Panel Thickness: 0.8mm to 6.0mm Gasket Locking Ring Extended with Full Shroud 1 block 3 blocks 2 blocks 4 blocks 29.5mm D1 0.5mm 50.2mm 70.2mm 65.8mm 85.8mm 29mm 23.5mm Mushroom Mushroom 29mm 23.2mm 18.5mm D1 W/ Transformer 40mm 23.4mm Extended D1 89.5mm 109.5mm 2 blocks 4 blocks D1 Mushroom 40mm 23.2mm 18.5mm Square 24V AC/DC Round M3.5 Terminal Screws W/ Dummy Block & W/ Full Voltage Adaptor Full Voltage Adaptor 29.6mm ck 40mm 25mm Lo 30mm W/ Transformer M3.5 Terminal Screws D1 = 0.51" 13mm www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-101 Switches & Pilot Devices 1.33" (34mm) 1.15in.(29.2mm) Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Unibody Illuminated A3 Panel Thickness 0.8mm to 6.0mm Panel Thickness 0.8mm to 6.0mm Gasket Gasket Locking Ring Locking Ring M3.5 Terminal Screws 40mm M3.5 Terminal Screws 40mm 46mm 60mm 11.5mm 11.5mm 48mm 32mm 63mm 14mm 14mm 32mm Selector Switches Panel thickness: 0.8mm to 6.0mm Gasket M3.5 Terminal Screws 25mm Loc k 37mm 28.8mm 29 m m Locking Ring 0.5mm 1-2 blocks 48.5mm 29.4mm 3-4 blocks 68.5mm Illuminated Selector Switches Pushlock Key Reset Panel Thickness 0.8mm~6mm Panel thickness: 0.8mm to 6.0mm m 40 Rubber Washer 0.5mm 25mm 40.4mm 28.8mm 2 blocks 89.5mm 4 blocks 109.5mm m Lock Lock Nut Locking Ring ø Gasket 21mm 48.5mm 21mm 50.3mm 13mm 30mm 32mm 49.4mm Key Switches M3.5 Terminal Screws 17mm 25mm 29 Loc k m m Panel thickness: 0.8mm to .0mm Gasket Locking Ring 17mm Switches & Pilot Devices Non-Illuminated 0.5mm D1 = 13mm 1-2 blocks 48.5mm 3-4 blocks A3-102 www.idec.com 68.5mm D1 29.4mm 30.5mm USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Dual Pushbutton Switches HW Without Pilot Light A3 Switches & Pilot Devices 49.4 (2 contacts) 69.4 (3 or 4 contacts) Panel Thickness 0.8 to 6 Safety Lever Lock Locking Ring Without Button Markings With Button Markings (I/ON and O/OFF) 54.8 54.8 41.4 ON OFF Rubber Gasket 0.5 29.8 14.5 20 29.8 With Pilot Light • Full Voltage Ful Voltage Adapter • The depth of 3-contact type depends on the combination of contact blocks at top and bottom pushbuttons. HW (Bottom Button) (Top Button) 69.4 (2 contacts), 89.4 (4 contacts) (Note) •Transformer (240V maximum) Top Button Bottom Button Depth 1 contact block 2 contact blocks 89.4 mm 2 contact blocks 1 contact block 69.4 mm • Transformer (480V) Transformer Transformer, DC-DC Converter HW HW 79.5 (2 contacts), 99.5 (4 contacts) 89.5 (2 contacts), 109.5 (4 contacts) Mounting Hole Layout R0.8 max. .3 +0.4 55 ∗∗ 0 +0.2 0 24.1 +0.4 0 ∗3.2 ø22 30 • The 3.2 mm recess is for preventing rotation and is not necessary when a nameplate or anti-rotation ring is not used. • When using the safety lever lock, determine the vertical spacing in consideration of convenience for installing and removing the safety lever lock. • Recommended vertical spacing: 100 mm • The minimum mounting centers are applicable to switches with one layer of contact blocks (two contact blocks). When two layers of contact blocks are mounted, determine the minimum mounting centers in consideration of convenience for wiring. All dimensions in mm. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-103 Oiltight Switches & Pilot Devices ø22mm - HW Series Dimensions con’t Jumbo Dome Pilot Lights Dimensions 6 ø6 Base BA9S/13 Illumination Color Light blue: LSTDB R0.8 max. ø22.3 3.2 +0.2 0 +0.4 0 24.1 +0.4 0 ø10.6 M3.5 Terminal Screw 85 20.4 Incandescent Lamp LSB Locking Ring Rubber Gasket 0.5 34.4 Base BA9S/13 ø10 ±1 50.5 85 27 ±2 Accessory Dimensions OB-31 Rubber Mounting Hole Plug 3mm LW9Z-BM Metallic Mounting Hole Plug TOP HW9Z-D7D Dual Pushbutton Rubber Cover 3.5mm ø 25mm 59mm 1.5mm HW-VG1 Dual Pushbutton Barrier MW9Z-T1 Locking Ring Wrench 22.5 33 ø 14mm ø 11.6mm m 9m ø2 m m 22 ø 3.5mm Gasket Lock Nut OR-55 Lamp/LED Removal Tool HW9Z-RL Anti-Rotation Ring ø 29mm 12mm ø 25.8mm 8 ø2 58 45 110 1.5 20 HW-VL1 Barrier HW9Z-KL1 Padlock Cover 82.5mm Mounting Hole Layout 45mm 22 .3 m m Panel Thickness 0.8mm - 3.2mm R m 20mm 50mm 45mm minimum {Note 2} .5m 93mm 66 30mm 70mm Switches & Pilot Devices A3 Mounting Hole Layout LED Lamp LSTDB All dimensions in mm. Panel Thickness 1 to 5 1.5mm 24mm ø m m .2 22 ø m m 50 Pad Lock Hole ø 8mm Waterproof Gasket Thickness 0.5mm 29.5mm HWLS-TK1971 Safety Lever Lock 30mm A3-104 www.idec.com Ø 3.5mmm Push to Set Note 1: Mushroom Button 40mm Type: 40mm or more Note 2: Pilot Light: 30mm minimum 0.49" (12.5mm) 0.31" (8mm) 30mm {Note 1} 0.50" (12.8mm) The values represent the minimum mounting centers when one stack of contact blocks is used. When two stacks or an illuminated unit is used, refer to the dimensions and considerwiring accessibility to determine minimum mounting centers. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Accessory Dimensions con’t HW9Z-KG2-TK2120 HW9Z-KG1-TK2120 64.0 48.0 32.0 ø76.1 Switches & Pilot Devices 80.0 A3 36.5 2 2. ø2 38.0 22.0 ø90 2.0 .0 Gasket ø2 TOP Marking TOP Mark TOP Marking TOP Mark Locking Ring Locking Ring Operator Operator Panel Thickness: 1.2 to 4.0 mm Panel Thickness: 1.2 to 4.0 mm Specification Charts — HW Series Rated Operational Power DC Voltage Inductive Millions of operating cycles AC Voltages Voltage V Current A 24 4 48 2 110 1.1 DC Voltages AC Voltages 5 0 0 V AC 1 2 0 V AC 1 . 0 4 8 0 V AC 4 0 0 V AC 3 8 0 V AC 2 4 0 V AC 0.5 0.2 0.1 1 6 0 0 V AC 2 3 4 5 6 10 Voltage V Current A 6 0 0 V AC Millions of operating cycles DC Voltages Resistive 1.0 24 8 www.idec.com 110 2.2 1 2 0 V AC 5 0 0 V AC 4 8 0 V AC 4 0 0 V AC 3 8 0 V AC 2 4 0 V AC 0.5 0.2 0.1 1 2 3 4 5 6 10 Current in A Current in A Conforming to IEC 947-5-1 Appendix C. Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Load factor: 0.4 ± 0.05 48 4 Conforming to IEC 947-5-1 Appendix C. Utilization categories AC-15 and DC-13. Operation rate: 1,800 op. hour Load factor: 0.9 ± 0.05 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-105 ø22mm - HW Series Oiltight Switches & Pilot Devices HW Safety Precautions Switches & Pilot Devices A3 HW Series Safety Precautions • Turn off power to HW series control units before starting installation, removal, wiring, maintenance, and inspection of the products. Failure to turn power off may cause electrical shocks or fire hazard. • To avoid the possibility of burning yourself, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper size to meet voltage and current requirements. Tighten the M3.5 terminal screws to a tightening torque of 1.0 to 1.3 N·m. Failure to tighten terminal screws may cause overheating and fire. HW General Instructions Panel Mounting Remove the contact block assembly from the operator (for transformer type pilot lights, remove the transformer from the illumination unit). Remove the locking ring from the operator. Insert the operator into the panel cut-out from the front, tighten the locking ring from the back, then install the contact block assembly to the operator. Removing and Installing the Contact Block Assembly 1. To remove the operator from the contact block, turn the locking lever in the direction of the arrow shown below. The operator can now be removed. 2. To reinstall, place the TOP markings on the operator and the contact block mounting adapter in the same direction, and insert the operator into the contact block mounting adapter. Then turn the locking lever in the opposite direction. Safety Lever Lock IDEC strongly recommends using the safety lever lock (HW9Z-LS, yellow) to prevent heavy vibration or maintenance personnel from unlocking the contact assembly. 1. HW series can be mounted vertically with a minimum spacing of 55 mm but spacing should be determined to ensure easy operation (recommended minimum spacing: 100 mm). 2. Mount the control unit onto the panel, lock the lever, and push in the safety lever lock to install. 3. When the spacing is narrower than the recommended value, with the lever unlocked, mount the safety lever lock and insert the contact unit to the operator. Then, lock the lever and strongly push in the safety lever lock to install. 4. To remove the safety lever lock, insert a flat screwdriver into the safety lever and push upwards. Removing and Installing the Safety Lever Lock Safety Lever Lock ➀ Push Safety Lever Lock Remove Screwdriver Lock Lever ➁ Install Operator Contact Block Notes for Panel Mounting 1. When mounting the operator onto a panel, use the optional locking ring wrench (MW9Z-T1) to tighten the locking ring. Tightening torque must not exceed 2.0 N·m. Do not use pliers. Excessive tightening will damage the locking ring. 2. For the contact blocks and transformers housing LED and incandescent lamps, make sure not to press the lamps too hard, otherwise the lamp socket may be damaged. Removing ➂ Lock Panel Installing Dual Pushbutton Instructions Replacement of Lens Removing • Remove the lens by inserting a screwdriver into the recess of the lens through the bezel. Installing • Install the lens in the recess between the buttons by pressing against the bezel. A3-106 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - HW Series Dual Pushbuttons Instructions con’t Tightening Torque for Terminal Screws Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3 N·m . Installation of LED Illuminated Units When using full voltage type LED illuminated units, provide protection against electrical noise, if necessary. Applicable Wiring The applicable wire size is 2 mm2 maximum. (solid wire ø1.6 mm maximum) One or two wires can be connected. Applicable Crimping Terminal ø3.6 min. 7.9 max. Installation 1. To install, insert the lamp head into the lamp holder tool, and hold the lamp as shown in the figure below. 4 max. Lamp 5.5 min. Lamp Holder Tool ø1.6 max. Be sure to use an insulation tube or cover on the crimping part of the crimping terminal to prevent electrical shocks. Solid Wire 2. Place the pins on the lamp base to the grooves in the lamp socket. Insert the lamp and turn it clockwise. Lamp Base 8 max. Note: When connecting wires to contact blocks or transformers in the direction shown below, keep the insulation stripping length 6.6 mm at the maximum. About Pushbutton Switches The pushbuttons cannot be removed or replaced! Do not attempt to remove using a flat screwdriver or pincers, otherwise the pushbuttons may be damaged. Do not attempt to remove the pushbuttons! Pushbuttons X1 Narrow Mounting When mounting the units closely in a horizontal row on 30mm centers, use optional barriers to prevent interconnection between adjoining terminals. The barriers can be attached simply by pressing them onto the sides of contact blocks. 30 30 Installing the Rubber Cover When using the HW7D pushbuttons in places where the pushbuttons are subjected to water splash or an excessive amount of dust, make sure to use the HW9Z-D7D rubber boot (IP65) which is ordered separately. Notes for Installing the Rubber Cover Remove the gasket from the operator, and install the rubber boot on the operator. Pull out the seals of the rubber boot and place them around the operator sleeve as shown. Make sure that the seals are not twisted or tucked inside and that the gasket does not remain, otherwise the normal waterproof and dustproof characteristics are not ensured. ➀ Remove the gasket. Barrier X2 ➁ Install the rubber boot on the pushbuttons. ➂ Rubber boot is installed. Seals When mounting transformer type illuminated units closely in a horizontal row on 30-mm centers, insert solid wires or stranded wires into inside of the terminal screw on the transformer (see figure on the right) to prevent short circuit between adjoining terminals. www.idec.com Install Remove X1 X2 X1 X2 Gasket Seals Inside Inside USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-107 A3 Switches & Pilot Devices Replacement of Lamps Lamps can be replaced by using the lamp holder tool (OR-55) from the front of the panel, or by removing the contact block assembly from the operator unit. Removing the Lamps from the Front of the Panel Removal 1. To remove, slip the lamp holder tool onto the lamp head lightly. Then push slightly, and turn the lamp holder tool counterclockwise. Oiltight Switches & Pilot Devices ø22mm - LW Series LW Series — Switches and Pilot Devices: 22mm Switches & Pilot Devices A3 LW Series offer flexibility in space-saving package Key features include: • PC board mount, solder or screw terminal • Collective mounting saves space • Non-reflective lens • Highly visible marking plate • Tamper proof construction • Light touch reduces strain • Gold or silver contacts • Removable contacts simplify wiring and facilitate PCB applications LW Series switches and pilot lights can be mounted collectively on 1.0" centers. Combined with pcb terminals and locking lever removable contacts, this eases manufacture of pre-fab pushbutton arrays (as pictured). PC Board tracing/soldering of contacts can be done in tandem with panel cutting/operator installation. All LW series units mount by means of a locking ring that comes on from the rear of the panel, as such they can not be removed from outside the panel and are relatively tamperproof. Combining the snap action and tactile feel of miniature commercial pushbuttons with the size and ruggedness of industrial pushbuttons, LW pushbuttons are a unique solution to many applications. Choose from standard silver contacts or low-level gold plated contacts. Terminals available in .110" solder tab, M3 screw, or pcb pins. UL Recognized File # E55996 A3-108 CSA Certified File No. LR21451 www.idec.com Registration No. J9551801 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Specifications Operating Temperature –25 to +60°C (without freezing) LED illuminated type: –25 to +50°C Storage Temperature –40 to +80°C Operating Humidity 45 to 85% RH Contact Resistance 50mΩ maximum (initial value) Insulation Resistance 100MΩ minimum (500V DC megger) Specifications Switch Unit Between live part and ground: 2,500V AC, 1 minute Between terminals of different poles: 2,500V AC, 1 minute Between terminals of the same pole: 1,000V AC, 1 minute Illumination Unit Between live part and ground: 2,500V AC, 1 minute Vibration Resistance Operating extremes: 5 to 55Hz, Amplitude 1.0mm p-p Shock Resistance Damage limits: 1,000 m/sec2 (Approx. 100G) Operating extremes: 100 m/sec2 (Approx. 10G) Mechanical Life Momentary: 1,000,000 operations minimum Maintained: 500,000 operations minimum Selectors: 250,000 operations minimum Electrical Life Momentary: 100,000 operations minimum (at 1,800 operations/hour) Maintained/Selector: 100,000 operations minimum (at 900 operations/hour) Degree of Protection Watertight/oiltight IP65 (IEC Pub529) (except key selectors) Insulation Voltage 250VAC/DC Lenses Materials polyarylate Operators polyacetate Marking Plates acrylic resin .110" Solder tab/quick connect PC board terminal (gold contacts only) Screw terminal (DPDT units only) Terminal Style Contact Material Contact Ratings Gold-clad cross-bar Switches & Pilot Devices Dielectric Strength A3 Thermal Current 3A Contact Rating Remarks 30VDC/0.1A resistive Minimum applicable load (reference value): 5V, 1mA AC/DC. (Applicable range is subject to the operating condition and load.) 125VAC/0.1A resistive 30VDC/2A resistive 30VDC/1A inductive 125VAC/3A resistive(50/60Hz) Silver Contact 125VAC/2A inductive (50/60Hz) 5A 125VDC/0.4A resistive AC inductive load: PF=0.6 to 0.7, DC inductive load: L/R=7ms maximum. 125VDC/0.2A inductive 250VAC/2A resistive(50/60Hz) 250VAC/1.5A inductive (50/60Hz) Incandescent LED Lamp Ratings Voltage Current/Wattage 6V AC/DC ±10% 17mA max 12V AC/DC ±10% 11mA max 24V AC/DC ±10% 11mA max 120V AC ±10% 10mA max 240V AC ±10% 10mA max 6.3V AC/DC ±5% 1W 12V AC/DC ±10% 1W 24V AC/DC ±10% UL Recognized File # E55996 CSA Certified File No. LR21451 Registration No. J9551801 1W LED lamps contains a built-in current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-109 Oiltight Switches & Pilot Devices ø22mm - LW Series Non-Illuminated Pushbuttons (Assembled) Part Numbers: LW1B/LW2B Pushbuttons Part Number Style Switches & Pilot Devices A3 Contact Contact Material Round Flush Gold Silver Square Flush Gold Silver Round Extended Gold Silver Square Extended Gold Silver Mushroom Gold Silver Momentary Solder/Tab PC Board SPDT LW1B-M1C1-① DPDT LW1B-M1C2-① 3PDT LW1B-M1C3-① LW1B-M1C3V-① SPDT LW1B-M1C5-① — Maintained (Latching) Screw Solder/Tab PC Board Screw LW1B-M1C1V-① — LW1B-A1C1-① LW1B-A1C1V-① — LW1B-M1C2V-① LW1B-M1C2M-① LW1B-A1C2-① LW1B-A1C2V-① LW1B-A1C2M-① — LW1B-A1C3-① LW1B-A1C3V-① — — LW1B-A1C5-① — — DPDT LW1B-M1C6-① — LW1B-M1C6M-① LW1B-A1C6-① — LW1B-A1C6M-① 3PDT LW1B-M1C7-① — — LW1B-A1C7-① — — SPDT LW2B-M1C1-① LW2B-M1C1V-① — LW2B-A1C1-① LW2B-A1C1V-① — DPDT LW2B-M1C2-① LW2B-M1C2V-① LW2B-M1C2M-① LW2B-A1C2-① LW2B-A1C2V-① LW2B-A1C2M-① 3PDT LW2B-M1C3-① LW2B-M1C3V-① — LW2B-A1C3-① LW2B-A1C3V-① — SPDT LW2B-M1C5-① — — LW2B-A1C5-① — — DPDT LW2B-M1C6-① — LW2B-M1C6M-① LW2B-A1C6-① — LW2B-A1C6M-① 3PDT LW2B-M1C7-① — — LW2B-A1C7-① — — SPDT LW1B-M2C1-① LW1B-M2C1V-① — LW1B-A2C1-① LW1B-A2C1V-① — DPDT LW1B-M2C2-① LW1B-M2C2V-① LW1B-M2C2M-① LW1B-A2C2-① LW1B-A2C2V-① LW1B-A2C2M-① 3PDT LW1B-M2C3-① LW1B-M2C3V-① — LW1B-A2C3-① LW1B-A2C3V-① — SPDT LW1B-M2C5-① — — LW1B-A2C5-① — — DPDT LW1B-M2C6-① — LW1B-M2C6M-① LW1B-A2C6-① — LW1B-A2C6M-① 3PDT LW1B-M2C7-① — — LW1B-A2C7-① — — SPDT LW2B-M2C1-① LW2B-M2C1V-① — LW2B-A2C1-① LW2B-A2C1V-① — DPDT LW2B-M2C2-① LW2B-M2C2V-① LW2B-M2C2M-① LW2B-A2C2-① LW2B-A2C2V-① LW2B-A2C2M-① 3PDT LW2B-M2C3-① LW2B-M2C3V-① — LW2B-A2C3-① LW2B-A2C3V-① — SPDT LW2B-M2C5-① — — LW2B-A2C5-① — — DPDT LW2B-M2C6-① — LW2B-M2C6M-① LW2B-A2C6-① — LW2B-A2C6M-① 3PDT LW2B-M2C7-① — — LW2B-A2C7-① — — SPDT LW1B-M3C1-① LW1B-M3C1V-① — LW1B-A3C1-① LW1B-A3C1V-① — DPDT LW1B-M3C2-① LW1B-M3C2V-① LW1B-M3C2M-① LW1B-A3C2-① LW1B-A3C2V-① LW1B-A3C2M-① 3PDT LW1B-M3C3-① LW1B-M3C3V-① — LW1B-A3C3-① LW1B-A3C3V-① — SPDT LW1B-M3C5-① — — LW1B-A3C5-① — — DPDT LW1B-M3C6-① — LW1B-M3C6M-① LW1B-A3C6-① — LW1B-A3C6M-① 3PDT LW1B-M3C7-① — — LW1B-A3C7-① — — 1. In place of ①, specify Button Color Code from table below. 2. For sub-assembly part numbers, see page A3-111. 3. For dimensions, see page A3-120. 4. For accessories, see page A3-119. Part Numbers: Buzzers (IP20) ① Button Color Code Part Number Style Solder Tab PCB Basic LW1Z-1X4 LW1Z-1X4V With LED LW1Z-1X4D LW1Z-1X4DV 12-24V AC/DC+/- 10% 80 dB (at 0.1m) 7mA (DC), 20mA (AC) A3-110 Color www.idec.com Code Black B Green G Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Button = Completed Unit A3 Switches & Pilot Devices Part Numbers: Operators Part Number Style Momentary Maintained LW1B-M0 LW1B-A0 LW2B-M0 LW2B-A0 LW1B-M0L LW1B-A0L Round Square Mushroom Part Numbers: Buttons Part Number Type Flush Extended LW1A-B1-① LW1A-B2-① Round ① Button Color Code Square LW2A-B1-① LW2A-B2-① Mushroom — LW1A-B3-① Color Code Black B Green G Red R Blue S White W Yellow Y In place of ①, specify Button Color Code from table at right. Part Numbers: Contact Blocks Appearance Contact Material Gold Silver www.idec.com Contact Part Number Solder/Tab PC Board SPDT LW-C1 LW-C1V DPDT LW-C2 LW-C2V 3PDT LW-C3 LW-C3V SPDT LW-C5 — DPDT LW-C6 — 3PDT LW-C7 — Screw — LW-C2M — — LW-C6M — USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-111 Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Illuminated Pushbuttons (Assembled) Part Numbers: LW1L/LW2L Illuminated Pushbuttons (LED and Incandescent) Part Number Style Switches & Pilot Devices A3 Round Contact Contact Material Gold Silver Square Gold Silver Mushroom Gold Silver Momentary Solder/Tab PC Board SPDT LW1L-M1C10-➁ LW1L-M1C10V-➁ DPDT LW1L-M1C20-➁ LW1L-M1C20V-➁ 3PDT LW1L-M1C30-➁ SPDT LW1L-M1C50-➁ DPDT LW1L-M1C60-➁ 3PDT LW1L-M1C70-➁ SPDT DPDT 3PDT LW2L-M1C30-➁ SPDT LW2L-M1C50-➁ DPDT LW2L-M1C60-➁ 3PDT LW2L-M1C70-➁ SPDT DPDT 3PDT LW1L-M3C30-➁ SPDT LW1L-M3C50-➁ DPDT LW1L-M3C60-➁ 3PDT LW1L-M3C70-➁ Maintained (Latching) Screw Solder/Tab PC Board Screw — LW1L-A1C10-➁ LW1L-A1C10V-➁ — LW1L-M1C20M-➁ LW1L-A1C20-➁ LW1L-A1C20V-➁ LW1L-A1C20M-➁ LW1L-M1C30V-➁ — LW1L-A1C30-➁ LW1L-A1C30V-➁ — — — LW1L-A1C50-➁ — — — LW1L-M1C60M-➁ LW1L-A1C60-➁ — LW1L-A1C60M-➁ — — LW1L-A1C70-➁ — — LW2L-M1C10-➁ LW2L-M1C10V-➁ — LW2L-A1C10-➁ LW2L-A1C10V-➁ — LW2L-M1C20-➁ LW2L-M1C20V-➁ LW2L-M1C20M-➁ LW2L-A1C20-➁ LW2L-A1C20V-➁ LW2L-A1C20M-➁ LW2L-M1C30V-➁ — LW2L-A1C30-➁ LW2L-A1C30V-➁ — — — LW2L-A1C50-➁ — — — LW2L-M1C60M-➁ LW2L-A1C60-➁ — LW2L-A1C60M-➁ — — LW2L-A1C70-➁ — — LW1L-M3C10-➁ LW1L-M3C10V-➁ — LW1L-A3C10-➁ LW1L-A3C10V-➁ — LW1L-M3C20-➁ LW1L-M3C20V-➁ LW1L-M3C20M-➁ LW1L-A3C20-➁ LW1L-A3C20V-➁ LW1L-A3C20M-➁ LW1L-M3C30V-➁ — LW1L-A3C30-➁ LW1L-A3C30V-➁ — — — LW1L-A3C50-➁ — — — LW1L-M3C60M-➁ LW1L-A3C60-➁ — LW1L-A3C60M-➁ — — LW1L-A3C70-➁ — — 1. In place of ➁, specify the Lens Color Code from table below. 2. Lamps must be ordered separately for all illuminated pushbuttons. 3. For marking plate size and engraving area, see page A3-124. 4. For sub-assembly part numbers, see page A3-113. 5. For dimensions, see page A3-120. 5. For accessories, see page A3-119. Part Numbers: Lamps (not included in assemblies) Type Voltage Part Number LED Incandescent ➁ Lens/LED Color Code Color Code 6V AC/DC±10% LSTD-6➁ Amber A 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-112 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Lamp + Lens = Completed Unit A3 Part Numbers: Lenses Part Number Style Switches & Pilot Devices Part Numbers: Operators Momentary Part Number Type Maintained Round Flush Round LW1L-M0 LW1A-L1-➁ LW1L-A0 Square Square LW2A-L1-➁ LW2L-M0 LW2L-A0 Mushroom LW1A-L3-➁ Mushroom LW1B-M0L LW1B-A0L In place of ➁, specify Lens Color Code from table below. Part Numbers: Contact Blocks Appearance Contact Material Contact Gold Silver Part Number Solder/Tab PC Board SPDT LW-C10 LW-C10V — DPDT LW-C20 LW-C20V LW-C20M 3PDT LW-C30 LW-C30V — SPDT LW-C50 — — DPDT LW-C60 — LW-C60M 3PDT LW-C70 — — Part Numbers: Lamps (not included in assemblies) Type Voltage Part Number LED Incandescent Screw ➁ LED/Lens Color Code Color Code 6V AC/DC±10% LSTD-6➁ Amber A 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-113 Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Pilot Lights (Assembled) Part Numbers: LW1P/LW2P Pilot Lights Switches & Pilot Devices A3 Type Part Number Style Solder/Tab PC Board Screw Round Removable Terminal Pilot Light — LW1P-1C00V-➁ — — LW2P-1C00V-➁ — Square Round Unibody Pilot Light LW1P-10-➁ — LW1P-10M-➁ LW2P-10-➁ — LW2P-10M-➁ Square 1. In place of ➁, specify the Lens Color Code from table below. 2. For marking plate size and engraving area, see page A3-124. 3. Lamps must be ordered separately, see table below. 4. For sub-assembly part numbers, see page A3-115. 5. For dimensions, see page A3-120. 6. For accessories, see page A3-119. Part Numbers: Lamps (not included in assemblies) Type Voltage Part Number LED Incandescent ➁ Lens/LED Color Code Color Code 6V AC/DC±10% LSTD-6➁ Amber A 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-114 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series LED and Incandescent Pilot Lights (Sub-Assembled) Removable Terminal* + Operator + Lamp + Lens = Completed Unit A3 Switches & Pilot Devices * Removable terminals are applicable for PCB terminated types only. Part Numbers: Pilot Light Operators Termination Style Solder PC Board Screw LW1P-00 LW1P-0 † LW1P-00M LW2P-00 LW2P-0 † LW2P-00M Round Square 1. † Requires LW-C00V removable terminals in addition to operator. 2. Solder and screw terminals are unibody design (they do not use a removable terminal block). Part Numbers: Lenses Type Part Number Round LW1A-P1-➁ Square LW2A-P1-➁ In place of ➁, specify Lens Color Code. Part Numbers: Lamps (not included in assemblies) Type Voltage Part Number LED Incandescent ➁ LED/Lens Color Code Color Code 6V AC/DC±10% LSTD-6➁ Amber A 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-115 Oiltight Switches & Pilot Devices ø22mm - LW Series Selector and Keylock Switches (Assembled) Part Numbers: LW1S Selector Switches Style Switches & Pilot Devices A3 Position Round Contact Material 90° 2-position maintained L Gold R Silver 45° 3-position maintained Gold C L R Silver Contact Solder/Tab Part Number PC Board Screw SPDT DPDT 3PDT SPDT DPDT 3PDT DPDT 3PDT DPDT LW1S-2C1 LW1S-2C2 LW1S-2C3 LW1S-2C5 LW1S-2C6 LW1S-2C7 LW1S-3C2 LW1S-3C3 LW1S-3C6 LW1S-2C1V LW1S-2C2V LW1S-2C3V — — — LW1S-3C2V LW1S-3C3V — — LW1S-2C2M — — LW1S-2C6M — LW1S-3C2M — LW1S-3C6M 3PDT LW1S-3C7 — — 1. Knob color: Black; Directional Indication Color: White 2. For contact operation, see next page. 3. For sub-assembly part numbers, see page A3-118. Part Numbers: LW1K Keylock Selector Switches Style Position Contact Material 90° 2-position maintained Gold Round L R Silver 45° 3-position maintained Gold C L R Silver Contact Part Number Solder/Tab PC Board Screw SPDT LW1K-2C1A LW1K-2C1VA — DPDT LW1K-2C2A LW1K-2C2VA LW1K-2C2MA 3PDT LW1K-2C3A LW1K-2C3VA — SPDT LW1K-2C5A — — DPDT LW1K-2C6A — LW1K-2C6MA 3PDT LW1K-2C7A — — DPDT LW1K-3C2A LW1K-3C2VA LW1K-3C2MA 3PDT LW1K-3C3A LW1K-3C3VA — DPDT LW1K-3C6A — LW1K-3C6MA 3PDT LW1K-3C7A — — 1. Every key selector uses an identical key. 2. The key is removable in all positions. 3. If a different configuration is required, contact an IDEC representative for more information. 4. For contact operation, see next page. 5. For sub-assembly part numbers, see page A3-118. Part Numbers: LW1F LED and Incandescent Illuminated Selector Switches Style Position Contact Material Round 90° 2-position maintained L Gold R Silver 45° 3-position maintained Gold C L R Silver Contact Part Numbers Solder/Tab PC Board SPDT LW1F-2C10-➁ LW1F-2C10V-➁ Screw — DPDT LW1F-2C20-➁ LW1F-2C20V-➁ LW1F-2C20M-➁ 3PDT LW1F-2C30-➁ LW1F-2C30V-➁ — SPDT LW1F-2C50-➁ — — DPDT LW1F-2C60-➁ — LW1F-2C60M-➁ 3PDT LW1F-2C70-➁ — — DPDT LW1F-3C20-➁ LW1F-3C20V-➁ LW1F-3C20M-➁ 3PDT LW1F-3C30-➁ LW1F-3C30V-➁ — DPDT LW1F-3C60-➁ — LW1F-3C60M-➁ 3PDT LW1F-3C70-➁ — — 1. In place of ➁, specify color code. See previous page for color codes. 2. Lamps must be ordered separately for all illuminated pushbuttons. See previous page. 3. For contact operation, see next page. 4. For sub-assembly part numbers, see page A3-118. A3-116 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Contact Operations Contact Operation: Selector and Keylock Switches Position Operator Position and Contact Position (Top View) Contact Left Right NC NO SPDT NC _ C Left L A3 Switches & Pilot Devices NO Center R NO C Right NC NO Left NC NO DPDT Right NC NO NC _ 90° 2-Position Maintained C C C Left Center Right NO NC NO NC NO NC C Left Center Right NO NC NO NC NO NC 3PDT _ C C Left NO C C Left Right NO NC NC NO Right NC NO C Left NC NO C Right NC NO NC DPDT C L R C C 45° 3-Position Maintained C C C C Left Center Right Left Center Right Left Center Right NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC NO NC 3PDT C C C C C C C C C Terminal Arrangements (Bottom View): LW❏L and LW❏B Pushbuttons www.idec.com NC NO C NC NO C NC NO C NO NC NO C SPDT has C, NO and NC only on the center. DPDT has C, NO, and NC only on the right and left. C X1 Lamp Terminal (—) 3 pole non-illuminated NC Lamp Terminal (+) X2 NC NO C NC NO C NC NO C Lamp Terminal (—) X2 Lamp Terminal (+) X1 2 pole illuminated X2 3 pole illuminated SPDT has C, NO and NC only on the right. DPDT has C, NO, and NC only on the right and center. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-117 Oiltight Switches & Pilot Devices ø22mm - LW Series Selectors and Key Switches (Sub-Assembled) Contact Block + Operator + Lens* = Completed Unit Switches & Pilot Devices A3 *Lens for illuminated units only Part Numbers: Operators Unit Position Part Number Non-Illuminated Selector Switch 2-position LW1S-2Y 3-position LW1S-3Y 2-position LW1K-2A 3-position LW1K-3A 2-position LW1F-20* 3-position LW1F-30* Key Switch Part Numbers: Knob (Lens) Style Part Number Illuminated Selector Switches LW1A-F-➁ Illuminated Selector Switch In place of ➁, specify LED/Lens Color Code from table below. * Lens must be purchased separately for illuminated units. Part Numbers: Contact Blocks Appearance Style Contact Material Gold Illuminated Selector Switches Silver Gold Non-Illuminated Selector Switches Silver Part Numbers: Lamps (not included in assemblies) Type Voltage Part Number LED Incandescent Contact Part Number Solder/Tab PC Board SPDT LW-C10 LW-C10V Screw — DPDT LW-C20 LW-C20V LW-C20M 3PDT LW-C30 LW-C30V — SPDT LW-C50 — — DPDT LW-C60 — LW-C60M 3PDT LW-C70 — — SPDT LW-C1 LW-C1V DPDT LW-C2 LW-C2V 3PDT LW-C3 LW-C3V SPDT LW-C5 — DPDT LW-C6 — 3PDT LW-C7 — — LW-C2M — — LW-C6M — ➁ LED/Lens Color Code Color Code 6V AC/DC±10% LSTD-6➁ Amber A 12V AC/DC±10% LSTD-1➁ Green G 24V AC/DC±10% LSTD-2➁ Red R 120V AC±10% LSTD-H2➁ Blue S 240V AC ±10% LSTD-M4➁ White W 6.3V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and reverse polarity protection diode. A3-118 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Accessories — LW Series Style Ring Wrench (optional) Part Number 1. Metallic tool used for tightening the plastic locking ring when installing the LW series on a panel. 2. Tightening torque should not exceed 1.2N-m (12 kgf-cm) when tightening a locking ring. LW9Z-T1 A3 Switches & Pilot Devices Lamp Holder Tool (optional) Description/Usage Rubber tool used for replacing incandescent or LED lamps installed in illuminated switches and pilot lights and pilot lights ø0.546" ø0.452" (ø14mm) (ø11.6mm) OR-55 2.301" (59mm) Terminal Cover (for solder tab terminal) Terminal Cover (for screw terminal) Nylon cover for pushbuttons and selectors with solder terminals snaps onto contact block. (Insert the lead wires through terminal cover holes before wiring.) LW-VL2 Nylon cover for pushbuttons and selectors for screw terminals snaps onto contact block. (Insert the lead wires through terminal cover holes before wiring.) LW-VL2M Nylon cover for unibody pilot lights with solder terminals. LW-PVL Nylon cover for unibody pilot lights with screw terminals. LW-PVLM Terminal Cover (for unibody pilot light with solder tab terminal) Terminal Cover (for unibody pilot light with screw terminal) Rubber Mounting Hole Plug Black rubber plug fills unused 22mm panel cutouts. 0.137" (3.5mm) ø1.131" (ø29mm) OB-31 0.137" (3.5mm) Metallic Mounting Hole Plug ø0.975" (ø25mm) 1. Used for plugging unnecessary mounting holes in the panel. Tighten the attached locking ring to a torque of 1.2N-m (12kgf-cm) maximum 2. Degree of Protection: IP66 ø1.0" (ø25.8mm) LW9Z-BM 0.468" (12mm) Replacement Marking Plates 0.117" (3mm) Locking Ring White plastic engraving plate for use on all illuminated units (included in each lens). May be used to capture printed mylar insert (not supplied by IDEC) under lens face. LW9Z-P1-W (round) Prevents rotation of switches in panel. (included with all selector and key switches only) LW9Z-L Replacement Keys One pair of keys. (#231) KG9Z-SK Replacement Locking Ring Use to secure operator to panel. (included with all assembled switches and operators) LW9Z-LN Anti-Rotation Ring LW9Z-P2-W (square) ALW3B (mushroom) For replacement lamps, see previous page. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-119 Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Pushbuttons LW❏L & LW❏B: Illuminated & Non-Illuminated Pushbuttons 4.85 6.8 6.8 4.85 6.2 Extended LOCK 9 6.8 2.0 6.8 8.2 12.6 47 16.2 18.2 NC NO 9 17 C X1 NC X2 NO C X2 16.2 K K K ø3 0 R18 R18 C C C 23.2 Mushroom LO LO R18 54.9 LO 25 25 25.4 26.5 Screw Terminal PC Board Terminal Solder/Tab Terminal Solder/Tab Terminal Width 2.8 × 0.5t Round Square Round w/Square Bezel 1.0 2.6 2-R0.6 36 5.4 ∗ PC Board Terminal 36 Gasket Locking Ring Terminal Cover LW-VL2 6.5 9 12.6 4.85 6.8 4.85 6.8 Extended 6.8 6.5 6.8 6.2 Panel Thickness: 0.8 to 6 mm 47 R18 Mushroom K C LO K C LO K C LO R18 54.9 R18 25.8 LOCK TOP 8.2 2.0 25.8 Solder/Tab Terminal M3 Screw terminal Terminal Cover LW-VL2M 9 ø3 0 Screw Terminal 9 8.5 11.7 ø2 5 2.6 53.5 .8 6 5 1.2 6 1.2 1.2 5 PC Board Terminal Width 0.8 × 0.5t NC NO NO C C 25.4 17 16.2 18.2 NC X1 X2 16.2 X2 9 23.2 25 25 26.5 Screw Terminal PC Board Terminal Solder/Tab Terminal Round Square Round w/Square Bezel 1.0 2.6 1.2 6 Tab Terminal (solder) Width 2.8 × 0.5t 1.2 1.2 5 PC Board Terminal 0.8 × 0.5t 2-R0.6 8 6 5 Screw Terminal A3-120 5.4 36 ∗ PC Board Terminal www.idec.com 9 36 5. 8.5 11.7 53.5 9 ø2 Switches & Pilot Devices Panel Thickness: 0.8 to 6 mm Locking Ring TOP A3 Gasket Terminal Cover LW-VL2 M3 Screw Terminal Terminal Cover LW-VL2M 25.8 25.8 Solder/Tab Terminal USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Pilot Lights LW1P/LW2P Pilot Lights Gasket Locking Ring Terminal Cover LW-PVL Terminal Cover LW-PVLM Panel Thickness: 0.8 to 6 mm Gasket 36 36 Tab Terminal (solder) Width 2.8 × 0.5t 5 Square Round w/Square Bezel 1.2 Round 7.7 26.8 Screw Terminal ∗ 2 19 7.5 27 9 5.5 Solder/Tab Terminal 9 25.8 25.8 PC Board Terminal 2.6 1.2 1.0 8.5 11.7 36 ø2 5.8 5 4.5 6.0 PC Board Terminal (solder) 0.8 × 0.5t 6.75 7.2 2-R0.6 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-121 Switches & Pilot Devices ∗ A3 LOCK TOP T O P O P 5.95 Panel Thickness: 0.8 to 6 mm Locking Ring 11.35 M3 Screw terminal Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Selector and Keylock Switches LW1S and LW1K Selector and Keylock Switches Gasket Locking Ring Terminal Cover 6.8 4.85 6.8 4.85 6.2 6.8 6.8 2.0 Anti-Rotation Ring 54.9 47 2.6 Tab Terminal (solder) Width 2.8 × 0.5t Round w/Square Bezel 6 1.2 Round 6 5 5 1.2 PC Board Terminal Width 0.8 × 0.5t ø2 5. 8 8.2 Switches & Pilot Devices Panel Thickness: 0.8 to 6 mm LOCK TOP 2 5.4 53.5 Screw Terminal 8.5 11.7 ∗ 36 9 36 PC Board Terminal 25.8 17.5 Gasket Locking Ring Panel Thickness 0.8 to 6 mm 4.85 6.8 9 Solder/Tab Terminal Terminal Cover LW-VL2 6.8 LOCK TOP Anti-Rotation Ring 0.5 Tab Terminal (solder) Width 2.8 × 0.5t ø2 5 Round Round w/Square Bezel 6 6 1.2 2.6 .8 47 8.5 11.7 10.5 R18 NC 25.8 37 Solder/Tab Terminal NC NO C X1 X2 NO C 16.2 23.2 36 9 K C LO K C LO R18 ∗ X2 1.0 25.4 25 Screw Terminal PC Board Terminal 2.6 1.2 A3 LW-VL2 M3 Screw Terminal Terminal Cover LW-VL2M 18.2 16.2 K C LO R18 2-R0.6 25 26.2 Solder/Tab Terminal A3-122 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Dimensions: Selector and Keylock Switches, continued and Layouts LW1F LED and Incandescent Illuminated Selector Switches Gasket Locking Ring Panel Thickness: 0.8 to 6 mm .8 6.8 A3 6.8 4.85 4.85 6.8 LOCK TOP 8.2 Round w/Square Bezel Anti-Rotation Ring 54.9 0.5 25.8 25.4 R18 18.2 NC NC NO C 16.2 X1 X2 NO 25 25 26.2 Solder/Tab Terminal Screw Terminal PC Board Terminal Solder/Tab Terminal 2.6 1.2 1.0 16.2 9 17.5 36 C R 18 23.2 6 8.5 11.7 9 X2 6 1.2 1.2 5 5 PC Board Terminal Screw Terminal 2.6 K 36 C 5.4 LO 53.5 K C LO Tab Terminal (solder) Width 2.8 × 0.5t K C LO PC Board Terminal (solder) 0.8 × 0.5t R18 47 2-R0.6 Layouts LW❏L PC Board Drilling Layout PC Board Terminal Bottom View LW❏B PC Board Drilling Layout PC Board Terminal Bottom View 0.265" 0.265" (6.8mm) (6.8mm) 0.265" (6.8mm) 0.195" 0.189" (4.85mm) 0.189" (4.85mm) 0.265" (6.8mm) 0.195" (5mm) 0.254" (5mm) Pilot Lights PC Board Drilling Layout PC Board Terminal Bottom View (6.5mm) 0.047" (1.2mm) ø0.047" (ø1.2mm) holes 0.047" (1.2mm) 0.195" 0.195" (5mm) (5mm) ø0.047" (ø1.2mm) holes 0.047" 1.014" (26mm) Note 2 (ø22.3+0.16" mm) 0 (5mm) 0.195" (5mm) (1.2mm) ø0.047" (ø1.2mm) holes Mounting Hole Layout ø0.87"+0.02" -0 0.443" (11.35mm) 0.195" 1. When determining mounting centerlines, allow for easy operation. 2. Mushroom (Ø 1.17" (Ø 30mm)) = 1.248" (32mm) Tab terminal = 1.014" (26mm) (with/without terminal cover) PC board terminal = 1.014" (26mm) Screw terminal = 1.56" (40mm) 3. Mushroom (Ø 1.17" (Ø 30mm) = 1.248" (32mm) Tab terminal = 1.053" (27mm) (with terminal cover) Tab terminal = 1.014" (26mm) (without terminal cover) PC board terminal = 1.014" (26mm) Screw terminal = 1.014" (26mm) 1.014" (26mm) Note 3 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-123 Switches & Pilot Devices 6.8 6.5 Terminal Cover LW-VL2M 6.5 Round ø2 5 Terminal Cover LW-VL2 M3 Screw Terminal Oiltight Switches & Pilot Devices ø22mm - LW Series Instructions — LW Series the same direction. Then push the lamp lightly and turn it clockwise. Replacement of Lens & Marking Plate Replacement of Lamps by Removing the Contact Block The lamp can be replaced by removing the contact block without using the lamp holder tool. Marking Plates & Films 2. Remove the marking plate by pushing the lens from the rear to disengage the latches between the lens and the lens holder, using the screwdriver as shown below. For LW series illuminated pushbuttons and pilot lights, legends and symbols can be engraved on marking plates, or printed mylar can be inserted under the lens for labelling purposes. Marking Plate and Marking Film Size Lens Style Round Lens Square Lens Engraving Area Engraving Area Built-in Marking Plate For Round Lens For Square Lens Lens Marking Plate Lens Holder Lens Marking Plate Lens Holder 0.033" (0.85mm) ø0.683" (ø17.5mm) Engraving must be made on the engraving area within 0.02" (0.5mm) deep. The marking plate is made of white acrylic resin. Installing For round lens types, place the marking plate on the lens holder with the antirotation projection engaged and press the lens onto the lens holder to engage the latches. For square lens types, insert the marking plate into the lens, and press the lens onto the lens holder to engage the latches. Pay attention to the orientation of the marking plate. Applicable Marking Film 0.772" 0.772" Pay attention to the orientation of the marking plate. ø0.694" (ø17.8mm) 0.033" (0.85mm) (19.8mm) The translucent filter in the lens holder can not be removed because this filter is sealed to make the unit waterproof and oiltight. (19.8mm) Switches & Pilot Devices A3 Grooves in the Operator Unit Removing 1. Remove the operator (lens, marking plate, and lens holder) by inserting a screwdriver into the recess of the lens through the bezel. 0.69" (17.7mm) Mylar for printing labels are not included and must be provided and printed by user. Two 0.004" (0.1mm)-thick films or one 0.008" (0.2mm)-thick film can be installed in the lens. Recommended marking film: Mylar Insertion Order of Marking Plate & Film Top Marking Side For Round Lens Replacement of Lamps Lamps can be replaced using the lamp holder tool (OR-55) from the front of the panel. Also by removing the contact block from the operator unit, the lamp can be replaced. Replacement of Lamps from the Front of the Panel. (How to Remove) 1. Push and turn the lamp counterclockwise using the side A of the lamp holder tool, and the lamp and the lamp holder can be removed. Lens Film Marking Plate Lens Holder Housing Insertion Order of Marking Plate & Film. Top Marking Side For Square Lens (How to Install) 1. Insert the lamp into the lamp holder tool and hold the lamp as in the following illustration. Lamp Lens Film Marking Plate Lens Holder Housing 1. Mylar is not included. 2. Pay attention to the orientation of marking plate. Lamp Holder Tool 2. Place the insertion guide of the lamp and the groove in the operator unit in A3-124 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - LW Series Instructions con’t Connection Remove the contact block from the operator. Insert the operator into the panel cut-out from the front, then install the contact block to the operator. Removing the Contact Block Turn the locking lever on the contact block in the direction opposite to the arrow on the housing. Then the contact block can be removed. Installing the Contact Block Insert the contact block, with the TOP markings on the contact block and the operator placed in the same direction. Then lock the units, turning the locking lever in the direction of the arrow. Positive-lock connector and easy-lock connector are applicable to tab terminals. A3 Single Board Mounting Mounting the switches and pilot lights on one PC board offers the following features. 1. Reduced installation labor, easy wiring, space saving, and standardization. 2. Since the contact blocks on the PC board can be removed easily using a locking lever, the LW series switches and pilot lights are easy to maintain. 3. Because the LW series switches and pilot lights require no studs for fastening the control unit to a PC board, special preparation of operation panel is not needed. For details on one board mounting, contact IDEC. Notes on Mounting Use the optional Ring Wrench (LW9Z-T1) to mount the operator onto a panel. Tightening torque should not exceed 1.2N-m (12 kgf-cm). Do not use pliers. Excessive tightening will damage the locking ring. Wiring 1. Solder the terminals within 20W/5 seconds or 260°C/3 seconds without exerting external force to the terminals. While soldering, do not touch the soldering iron to the housing. While wiring, prevent tension from being applied to the terminals. Do not bend or raise the terminals, nor exert excessive force to terminals. 2. Use a non-corrosive resin liquid flux. Light Touch And High Reliability Collective Mounting As the locking lever can be turned easily from the rear of the units using a screwdriver, the contact blocks can be removed even when mounted collectively. Stroke 0.117" (3mm) Operating-force Snap Switching Mechanism Notes for Terminal Cover 2000 TW series pushbutton (SPST-NO/SPST-NC) (Solder/Tab Terminal) Insert the terminal cover into the contact block with the TOP markings on the contact block and the terminal cover in the same direction. When wiring, insert the lead wires into the terminal cover holes before wiring. 1500 Load (g) 1000 500 LW series pushbutton (Momentary DPDT) LW series pushbutton (Momentary SPDT) Notes for Wiring When installing a terminal cover onto the solder/tab terminal contact block, solder the inside of lamp terminal (toward the switch terminals) and wire. (Screw Terminal Type) Install a terminal cover to the control unit before wiring. 0 0.039" 0.078" 0.117" 0.156" 0.195" 0.234" (1mm) (2mm) (3mm) (4mm) (5mm) (6mm) Stroke 1. After wiring, terminal covers cannot be installed. 2. When terminal covers are used, round crimping terminals cannot be used. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-125 Switches & Pilot Devices Panel Mounting Oiltight Switches & Pilot Devices ø22mm - TW Series TW Series — 22mm NEMA Style Pushbuttons Switches & Pilot Devices A3 TW NEMA Style Switches with snap-on contacts Key features include: IDEC has your 22mm switching needs covered. • Corrosion resistant octagonal chrome plated locking bezel • Snap-on 10A contact blocks • Transformer or full voltage • Incandescent or LED illumination • Slow make, double break, self cleaning contacts •Modular construction for maximum flexibility •NEMA 4X and IP65 watertight/oiltight panel •Available assembled or as sub-components •Large M3.5 screw terminals with captive sems plate Button styles include flush, extended, mushroom, or square and all bodies are crafted from fracture-resistant nylon. UL Listed File No. E70646 A3-126 File No. 9561116E01 www.idec.com CSA Certified File No.LR48366 All illuminated units feature two lense styles, one that maximizes light dispersion, the other accommodates direct lense engraving. Self cleaning contact mechanisms allow for a wide current rating, 5mA to 10A, which reduces the need for various contact materials. When looking for a 22mm switch that is durable, easy to use, and versatile, then IDEC's TW series is your solution. File No. DK95-01696 Certificate No. 2030010305027380 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices Conforming to Standards Approvals File No. E68961 EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 File No. LR21451 Certificate No. 2030010305027380 Specifications CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operating Temperature Operation: –25 to +50°C (without freezing) Storage: –40 to +80°C (without freezing) Vibration Resistance Shock Resistance Electric Shock Protection Degree of Protection (conforming to IEC60529) (conforming to NEMA ICS6-110) 5 to 55Hz, 100m/sec2 (10g) conforming to IEC6068-2-6 Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 3 for switches not using a transformer 2 for switches using a transformer AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Pollution Degree (conforming to IEC60947-1) Rated Operational Characteristics A3 Switches & Pilot Devices Registration No: J9551802 (E-Stops) Registration No: J9551803 (All other switches) Registration No: J9551804 (Pilot Lights) Contact Ratings ø22mm - TW Series 1000m/sec2 (100g) conforming to IEC6068-2-7 Class 0 conforming to IEC60536 IP65 from front of the panel; (IP54 for key switches) IP20 (Type HW-F contact block) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (NEMA 1, 2, 3R, 5, 12, 13 for key switches) Rated Insulation Voltage Rated Switching Over-Voltage 600V Rated Impulse Withstanding Voltage 4kV for contact circuit 2.5kV for lamp circuit Rated Thermal Current Minimum Switching Capacity Contact Operation Recommended Terminal Torque External Short-Circuit Protection Applicable Wire Size Contact Resistance 10 Amp Contact Gap 4mm (NO and NC) 2mm (NO-EM and NC-LB) Electrical Reliability MTBF < 1 fault for 10 million operation cycles (3V DC, 5mA) Lamp Ratings Incandescent: 1 W LEDs: 6V: 17mA max, 12/24V: 11mA max, 120/240V: 10mA max Horsepower Rating Maximum Inrush Current Contact Material 1/4 HP @ 120V (single-phase, non-reversing motor); 1 HP @ 240V (3 phase, non-reversing motor) Pushbuttons Illuminated Pushbuttons Selector Switches Illuminated Selector Switches Pushbutton Selectors Less than 4kV, conforming to IEC60947-1 5 mA at 3V AC/DC Slow break NC or slow make NO, self-cleaning 0.8 N m (7.1 in lb.) 10A 250V fuse conforming to IEC60269-1 Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Initial contact resistance of 50mΩ or less 40 A (40 ms) Silver Contact Block Type HW-C/HW-F Rated Insulation Voltage 600V Rated Continuous Current 10A Contact Ratings by Utilization Category IEC 60947-5-1 AC-15 (A600) DC-13 (P600) Contact Ratings by Utilization Category Characteristics Operational Voltage Operational Current www.idec.com AC 50/60 Hz DC 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A — DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-127 ø22mm - TW Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Switches & Pilot Devices A3 Assembled Pushbuttons A B ( ) W 1 10 ( ) - B Function B: Momentary O: Maintained K: Key On/Off Lock Button Color B: Black G: Green W: White R: Red S: Blue Y: Yellow Terminal Style Blank: Standard N: Fingersafe (IP20) Bezel Shape Blank: Octagonal F: Full Shroud G: Mushroom Shroud Q: Square Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Button Shape 1: Flush 2: Extended 3: Mushroom Head Ø 29mm 4: Mushroom Head Ø 40mm Series Designation W: TW Series To be used for interpreting part numbers only, not for part number development. A3-128 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Pushbuttons (Assembled) con’t Part Numbers: Non-illuminated Pushbuttons Style Contacts ① Button Color Code Maintained Action Color Code 1NO 1NC 1NO-1NC 2NO 2NC ABW110-➀ ABW101-➀ ABW111-➀ ABW120-➀ ABW102-➀ AOW110-➀ AOW101-➀ AOW111-➀ AOW120-➀ AOW102-➀ Black B Green G Red R Extended 1NO 1NC 1NO-1NC 2NO 2NC ABW210-➀ ABW201-➀ ABW211-➀ ABW220-➀ ABW202-➀ AOW210-➀ AOW201-➀ AOW211-➀ AOW220-➀ AOW202-➀ Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFW110-➀ ABFW101-➀ ABFW111-➀ ABFW120-➀ ABFW102-➀ AOFW110-➀ AOFW101-➀ AOFW111-➀ AOFW120-➀ AOFW102-➀ Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFW210-➀ ABFW201-➀ ABFW211-➀ ABFW220-➀ ABFW202-➀ AOFW210-➀ AOFW201-➀ AOFW211-➀ AOFW220-➀ AOFW202-➀ Ø 29mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW310-➀ ABW301-➀ ABW311-➀ ABW320-➀ ABW302-➀ AOW310-➀ AOW301-➀ AOW311-➀ AOW320-➀ AOW302-➀ Ø 40mm Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABW410-➀ ABW401-➀ ABW411-➀ ABW420-➀ ABW402-➀ AOW410-➀ AOW401-➀ AOW411-➀ AOW420-➀ AOW402-➀ Ø 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGW410-➀ ABGW401-➀ ABGW411-➀ ABGW420-➀ ABGW402-➀ AOGW410-➀ AOGW401-➀ AOGW411-➀ AOGW420-➀ AOGW402-➀ Square Flush 1NO 1NC 1NO-1NC 2NO 2NC ABQW110-➀ ABQW101-➀ ABQW111-➀ ABQW120-➀ ABQW102-➀ AOQW110-➀ AOQW101-➀ AOQW111-➀ AOQW120-➀ AOQW102-➀ Square Extended 1NO 1NC 1NO-1NC 2NO 2NC ABQW210-➀ ABQW201-➀ ABQW211-➀ ABQW220-➀ ABQW202-➀ AOQW210-➀ AOQW201-➀ AOQW211-➀ AOQW220-➀ AOQW202-➀ Keylock Push On/Off 1NO 1NC 1NO-1NC 2NO 2NC AKW210 AKW201 AKW211 AKW220 AKW202 Flush Blue S White W Yellow Y A3 Switches & Pilot Devices Momentary Action – 1. In place of ➀, specify the Button Color Code from table. 2. For sub-assembled part numbers, see page A3-130. 3. For accessories, see page A3-156. 4. For dimensions, see page A3-158. 5. Keyed switches are supplied with two keys. All units are keyed alike. For custom keys, contact IDEC. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-129 Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Blocks + Operator + Button = Complete Part Switches & Pilot Devices A3 Part Numbers: Operators Style Part Number Momentary Maintained Part Numbers: Buttons Style Part Number Round Flush Round Flush/Extended ABW1B-➀ ABW-100 Part Numbers: Contact Blocks Description Part Number AOW-100 Round Extended Round with Full Shroud 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Standard Exposed Screw ABW2B-➀ ABFW-200 Fingersafe (IP20), CE marked AOFW-200 Ø 29mm Mushroom ABW3B-➀ Ø 40mm, Ø 29mm Mushroom Head ABW-300 AOW-300 Dummy Block Ø 40mm Mushroom TW-DB ABW4B-➀ Ø 40mm Mushroom Head with Full Shroud ABGW-400 AOGW-400 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function Square Flush ABQW1B-➀ ① Button Color Code Square Flush/Extended Square Extended ABQW-100 AOQW-100 ABQW2B-➀ In place of ➀, specify the Button Color Code from table. Keylock Push On/Off Color Code Black B Green G Red R Blue S White W Yellow Y AKW-200 A3-130 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series E-Stops (Assembled) A3 A V (L) W 4 (B) (99) 11 (D) (N) - R - (24V) Function V: Pushlock Turn Reset Y: Push-Pull X: Pushlock Key Reset Lamp Voltage (full voltage illuminated units only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) 240V: 240V AC (LED only) Illumination Blank: None L: Illuminated Button/Lens Color A: Amber R: Red G: Green S: Blue B: Black Series Designation W: TW Series Button/Lens Size 3: 29mm Mushroom 4: 40mm Mushroom W: White Y: Yellow Contact Terminal Style Blank: Standard N: Fingersafe (IP20) Lens Type (illuminated units only) Blank: Standard (ribbed) B: Engravable (smooth with insert) Illuminated Circuit (illuminated unit only) 99: Full Voltage (lamp determines voltage) 126:120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Lamp Type (illuminated units only) Blank: Incandescent D: LED Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC Use only for interpreting part numbers. Do not use for developing part numbers. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-131 Switches & Pilot Devices Assembled E-Stops Oiltight Switches & Pilot Devices ø22mm - TW Series E-Stops (Assembled) con’t Part Numbers: Non-Illuminated E-Stops Style Contacts Part Number Ø 40mm Pushlock Turn Reset* Switches & Pilot Devices A3 Part Numbers: Illuminated E-Stops Style Type Ø 40mm Pushlock Turn Reset Type 1NO 1NC 1NO-1NC 2NO 2NC AVW410-R* AVW401-R* AVW411-R* AVW420-R* AVW402-R* 1NO 1NC 1NO-1NC 2NO 2NC AVW310-R* AVW301-R* AVW311-R* AVW320-R* AVW302-R* Ø 29mm Pushlock Turn Reset Ø 29mm Pushlock Turn Reset* Ø 40mm Push-Pull Ø 40mm Push-Pull 1NO 1NC 1NO-1NC 2NO 2NC AYW410-➀ AYW401-➀ AYW411-➀ AYW420-➀ AYW402-➀ Ø 40mm Pushlock Key Reset * 1NO 1NC 1NO-1NC 2NO 2NC AXW410AXW401AXW411AXW420AXW402- R* R* R* R* R* 1. *Available in Red only. 2. In place of ➀, specify the Button Color Code from table. 3. For sub-assembled part numbers, see page A3-130. 4. For accessories, see page A3-156. 5. For dimensions, see page A3-158. ① Button Color Code Color Code ➁ LED/Lens Color Code Color Voltage Code 6V B Amber A Green G Green G 12V AC/DC 12V 24V Red R Red R 24V AC/DC Blue S Blue S 120V AC 120V (LED only) W 240V AC 240V (LED only) Yellow Y White ➃ Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 126 246 486 Transformer 1NO-1NC 2NO 2NC AVLW4 ➃ 11⑤-R* AVLW4 ➃ 20⑤-R* AVLW4 ➃ 02⑤-R* Full Voltage 1NO-1NC 2NO 2NC AVLW49911➄-R*-➂ AVLW49920➄-R*-➂ AVLW49902➄-R*-➂ Transformer 1NO-1NC 2NO 2NC AVLW3➃11➄-R* AVLW3➃20➄-R* AVLW3➃02➄-R* Full Voltage 1NO-1NC 2NO 2NC AVLW39911➄-R*-➂ AVLW39920➄-R*-➂ AVLW39902➄-R*-➂ Transformer 1NO-1NC 2NO 2NC AYLW4 ➃ 11➄-➁ AYLW4 ➃ 20➄-➁ AYLW4 ➃ 02➄-➁ Full Voltage 1NO-1NC 2NO 2NC AYLW49911➄-➁-➂ AYLW49920➄-➁-➂ AYLW49902➄-➁-➂ ➂ Full Voltage Code Code Black W Part Number 1. *Available in red only. 2. In place of ➁, specify the Lens Color Code (see table above). 3. In place of ➂, specify the Full Voltage Code (lamp voltage) (see table above). 4. In place of ➃, specify the Transformer Voltage Code (see table above). 5. In place of ⑤, specify the Lamp Type Code from table above. 6. For sub-assembly part numbers, see page A3-134. 7. For accessories, see page A3-156. 8. For dimensions, see page A3-158. 6V AC/DC White Contacts ➄ Lamp Type Code Lamp Code Incandescent Blank LED D Transformers step down to 6V. A3-132 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series E-Stops (Sub-Assembled) Transformer/ + Adaptor* Contacts + Lamp Holder + Operator + Lamp + Button or Lens = Complete Part A3 Switches & Pilot Devices * Not applicable for full voltage units Part Numbers: Operators Style Part Number Non-illuminated Part Numbers: Buttons Style Illuminated Part Number Ø 40mm Pushlock Turn Reset Ø 29/Ø 40mm Pushlock Turn Reset AVW4B-R* AVW-300 AVLW3-0600 Ø 29mm Pushlock Turn Reset Ø 40mm Push-Pull AVW3B-R* AYW-400 AYLW4-0600 Ø 40mm Push-Pull Ø 40mm Pushlock Key Reset AYW4B-➀ AXW-300 — Ø 40mm Pushlock Key Reset Part Numbers: Lamps Type Voltage LED Incandescent AXW4B-R* Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. www.idec.com 1. *Available in Red only 2. In place of ➀, specify the button color code from table below. ① Button Color Code ➁ LED/Lens Color Code Color Code Color Code Black B Amber A Green G Green G Red R Red R Blue S Blue S White W White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-133 Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated E-Stops (Sub-Assembled) con’t Part Numbers: Lenses Style Switches & Pilot Devices A3 Part Numbers: Transformers/Full Voltage Modules Style Description Part Number Part Number Standard Engravable Full Size Transformer Standard Ø 29mm Head Pushlock Turn Reset AVLW3LU-R* AVLW3BLU-R* Fingersafe Half Size Transformer Ø 40mm Head Pushlock Turn Reset AVLW4LU-R* AVLW4BLU-R* Full voltage model (use with even number of contacts) Ø 40mm Head Push Pull AYLW4LU-➁ AYLW4BLU-➁ Full voltage model (use with odd number of contacts) 1. In place of ➁, specify the lens color code from table on the bottom right. 2. *Available only in red 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. Part Numbers: Lamp Circuit Components Style Application Used with a Half-size Transformer and one contact block Long Lamp Holder TW-T126B TW-T246B TW-T486B TW-F126B TW-F246B TW-F486B 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB All Transformers step down to 6V (use 6V lamp). Part Number Short Lamp Holder 120V AC 240V AC 480V AC 120V AC 240V AC 480V AC Part Numbers: Contact Blocks Description Part Number TW-LH1 1NO 1NC HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Standard Exposed Screw Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks TW-LH2 Used with TW-LH2 holder when using four contact blocks HW-LH3 Fingersafe (IP20), CE marked Lead Holder Dummy Block TW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function A3-134 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Pilot Lights (Assembled) A3 A P (Q) W 1 ( B) 99 Function P: Pilot Light (D) - R - (24V) Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) 240V: 240V AC (LED only) Bezel Shape Blank: Octagonal (round lenses) Q: Square Series Designation W: TW Series Lens Shape 1: Flat 2: Dome Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert included) Illumination Circuit 99: Full Voltage (lamp determines voltage) 126:120V AC Step Down Transformer 246:240V AC Step Down Transformer 486:480V AC Step Down Transformer Lens Color Code A: Amber G: Green R: Red S: Blue W:White Y: Yellow Lamp Type Blank: Incandescent D: LED 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-135 Switches & Pilot Devices Assembled Pilot Lights Oiltight Switches & Pilot Devices ø22mm - TW Series Pilot Lights (Assembled) con’t Part Numbers: Pilot Lights Style Switches & Pilot Devices A3 Round Flat Dome Square Flat Operating Voltage Part Number Transformer 120VAC 240VAC 480VAC APW1126➃-➁ APW1246➃-➁ APW1486➃-➁ Full Voltage — APW199➃-➁-➂ Transformer 120VAC 240VAC 480VAC APW2126➃-➁ APW2246➃-➁ APW2486➃-➁ Full Voltage — APW299➃-➁-➂ Transformer 120VAC 240VAC 480VAC APQW1B126➃-➁ APQW1B246➃-➁ APQW1B486➃-➁ Full Voltage — APQW1B99➃-➁-➂ 1. In place of ➁, specify the Lens Color Code from table below. 2. In place of ➂, specify the Full Voltage Code from table below. 3. In place of ➃, specify the Lamp Type Code from table below. 4. For accessories, see page A3-156. 5. For dimensions, see page A3-158. 6. For sub-assembly part numbers, see next page. ➁ Lens Color Code A3-136 Color Code Amber A Green G ➂ Full Voltage Code Lamp Code 6V AC/DC 6V Incandescent Blank 12V AC/DC 12V LED D Red R 24V AC/DC 24V Blue S 120V AC 120V (LED only) White W 240V AC 240V (LED only) Yellow Y www.idec.com ➃ Lamp Type Code Code Voltage USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Pilot Lights (Sub-Assembled) Transformer + Operator + Lamp + Lens = Complete Part A3 Switches & Pilot Devices * Transformer not required for full voltage units. Part Numbers: Operators Style Part Number Part Numbers: Lamps Type Voltage Round Dome/Flat LED APW-199 Incandescent Square UPQW-199 Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 30V AC/DC IS-30 1. In place of ➁, specify the LED Color Code from table below. 2. The LED contains a current-limiting resistor and diode bridge. Same operator is used for full voltage as for transformer completed units. Part Numbers: Transformers Description Style Part Numbers: Lenses Part Number Style Standard Engravable Dome APW2LU-➁ — Round Flat APW1LU-➁ APW1BLU-➁ Square Flat — APQW1BLU-➁ 1. In place of ➁, specify the Lens Color Code from table below. 2. Standard lenses have a ribbed lens to enhance light dispersion. Marking lenses are smooth and include an engravable insert. Standard Fingersafe 120V AC 240V AC 480V AC 120V AC 240V AC 480V AC Part Number TW-T126B TW-T246B TW-T486B TW-F126B TW-F246B TW-F486B All Transformers step down to 6V (use 6V lamp). ➁ Lens/LED Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y If clear lens is desired, use white marking lens and remove engraving insert www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-137 Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Assembled) Switches & Pilot Devices A3 Assembled Illuminated Pushbuttons A L (F ) W 2 (B) 99 11 (D) (N) - R - (24V) Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V:120V AC (LED only) 240V: 240V AC (LED only) Function L: Momentary Action OL: Maintained Action Bezel Shape Blank: Octagonal (round lenses) F: Full Shroud (round lenses) Q: Square Lens Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Series Designation W: TW series Lens Shape/Size 2: Standard Extended (round or square) 3: 29mm Mushroom 4: 40mm Mushroom Contact Terminal Style Blank: Standard N: Fingersafe Lens Type Blank: Standard (ribbed) B: Engravable (smooth with insert) Lamp Type Blank: Incandescent Lamp D: LED Lamp Illumination Circuit 99: Full Voltage (lamp determines voltage) 126:120V AC Step Down Transformer 246:240V AC Step Down Transformer 486:480V AC Step Down Transformer Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22:2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Transformers step down to 6V. A3-138 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Assembled) Part Numbers: Illuminated Pushbuttons Style Contacts Maintained 1NO-1NC 2NO 2NC ALW2 ➃ 11⑤-➁ ALW2 ➃ 20⑤-➁ ALW2 ➃ 02⑤-➁ AOLW2 ➃ 11⑤-➁ AOLW2 ➃ 20⑤-➁ AOLW2 ➃ 02⑤-➁ Full Voltage 1NO-1NC 2NO 2NC ALW29911⑤-➁-➂ ALW29920⑤-➁-➂ ALW29902⑤-➁-➂ AOLW29911⑤-➁-➂ AOLW29920⑤-➁-➂ AOLW29902⑤-➁-➂ Transformer Type 1NO-1NC 2NO 2NC ALFW2 ➃ 11⑤-➁ ALFW2 ➃ 20⑤-➁ ALFW2 ➃ 02⑤-➁ AOLFW2 ➃ 11⑤-➁ AOLFW2 ➃ 20⑤-➁ AOLFW2 ➃ 02⑤-➁ Full Voltage 1NO-1NC 2NO 2NC ALFW29911⑤-➁-➂ ALFW29920⑤-➁-➂ ALFW29902⑤-➁-➂ AOLFW29911⑤-➁-➂ AOLFW29920⑤-➁-➂ AOLFW29902⑤-➁-➂ Transformer Type 1NO-1NC 2NO 2NC ALW3 ➃ 11⑤-➁ ALW3 ➃ 20⑤-➁ ALW3 ➃ 02⑤-➁ AOLW3 ➃11⑤-➁ AOLW3 ➃20⑤-➁ AOLW3 ➃ 02⑤-➁ Full Voltage 1NO-1NC 2NO 2NC ALW39911⑤-➁-➂ ALW39920⑤-➁-➂ ALW39902⑤-➁-➂ AOLW39911⑤-➁-➂ AOLW39920⑤-➁-➂ AOLW39902⑤-➁-➂ Transformer Type 1NO-1NC 2NO 2NC ALW4 ➃ 11⑤-➁ ALW4 ➃ 20⑤-➁ ALW4 ➃ 02⑤-➁ AOLW4 ➃11⑤-➁ AOLW4 ➃20⑤-➁ AOLW4 ➃ 02⑤-➁ Full Voltage 1NO-1NC 2NO 2NC ALW49911⑤-➁-➂ ALW49920⑤-➁-➂ ALW49902⑤-➁-➂ AOLW49911⑤-➁-➂ AOLW49920⑤-➁-➂ AOLW49902⑤-➁-➂ Transformer Type 1NO-1NC 2NO 2NC ALQW2B ➃11⑤-➁ ALQW2B ➃20⑤-➁ ALQW2B ➃02⑤-➁ AOLQW2B ➃11⑤-➁ AOLQW2B ➃20⑤-➁ AOLQW2B ➃02⑤-➁ Full Voltage 1NO-1NC 2NO 2NC ALQW2B9911⑤-➁-➂ ALQW2B9920⑤-➁-➂ ALQW2B9902⑤-➁-➂ AOLQW2B9911⑤-➁-➂ AOLQW2B9920⑤-➁-➂ AOLQW2B9902⑤-➁-➂ Ø 40mm Mushroom Lens Square Extended A3 Switches & Pilot Devices Ø 29mm Mushroom Lens Momentary Transformer Type Extended Lens Extended Lens with Full Shroud Part Number 1. In place of ➁, specify the Lens Color Code (see table above). Mushroom lenses not available in yellow. 2. In place of ➂, specify the Full Voltage Code (lamp voltage) (see table above). 3. In place of ➃, specify the Transformer Voltage Code (see table above). 4. In place of ⑤, specify the Lamp Type Code from table above. 5. For sub-assembly part numbers, see page A3-140. 6. For accessories, see page A3-156. 7. For dimensions, see page A3-158. ➁ Lens/LED Color Code ➂ Full Voltage Code Voltage Code ➃ Transformer Voltage Codes Voltage Code Color Code Amber A 6V AC/DC 6V Green G 12V AC/DC 12V 120VAC 126 246 486 Red R 24V AC/DC 24V 240VAC Blue S 120V AC 120V (LED only) 480VAC White W 240V AC 240V (LED only) Yellow Y ⑤ Lamp Type Code Lamp Code Incandescent Blank LED D Transformers step down to 6V (use 6V lamp). Mushroom lenses not available in yellow. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-139 Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Sub-Assembled) Transformer/ + Adaptor* Contacts + Lamp Holder + Operator + Lamp + Lens = Complete Part Switches & Pilot Devices A3 * Not applicable for full voltage units Part Numbers: Operators Part Number Style Momentary Maintained Part Numbers: Lamps Type Voltage LED Part Number 6V AC/DC LSTD-6➁ LSTD-1➁ Extended ALW-0600 AOLW-0600 12V AC/DC Extended with Full Shroud ALFW-0600 AOLFW-0600 24V AC/DC LSTD-2➁ LSTD-H2➁ ø29mm/ø40mm Mushroom ALW3-0600 AOLW3-0600 120V AC Square/Extended ALQW-2B0600 AOLQW-2B0600 240V AC LSTD-M4➁ 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 Incandescent Part Numbers: Lenses Part Number Style Standard Engravable Round Extended ALW2LU-➁ ALW2BLU-➁ 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and a protection diode. Part Numbers: Lamp Circuit Components Style Application Ø 29mm Mushroom Head* ALW3LU-➁ ALW3BLU-➁ Part Number Short Lamp Holder Used with a Half-size Transformer and one contact block TW-LH1 Used with Full-size Transformer and two contact blocks Used with Half-size Transformer and three contact blocks Used with Full Voltage Adaptor and two contact blocks TW-LH2 Used with TW-LH2 holder when using four contact blocks HW-LH3 Ø 40mm Mushroom Head* ALW4LU-➁ ALW4BLU-➁ Long Lamp Holder Square Extended — ALQW2BLU-➁ 1. In place of ➁, specify the lens color code from table on the bottom right. 2. * Mushroom lens not available in yellow. 3. Standard lenses have ribbed pattern, Engravable lenses are smooth and include an engravable insert. A3-140 www.idec.com Lead Holder ➁ LED/Lens Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Pushbuttons (Sub-Assembled) con’t Part Numbers: Contact Blocks Description Part Number 1NO 1NC A3 Standard Exposed Screw HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Switches & Pilot Devices HW-C10 Fingersafe (IP20) Dummy Block TW-DB 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function. Part Numbers: Transformers/Full Voltage Modules Style Description Part Number Full Size Transformer Standard Fingersafe Half Size Transformer Full voltage model (use with even number of contacts) Full voltage model (use with odd number of contacts) 120V AC 240V AC 480V AC 120V AC 240V AC 480V AC TW-T126B TW-T246B TW-T486B TW-F126B TW-F246B TW-F486B 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB All Transformers step down to 6V (use 6V lamp). www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-141 Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Assembled) Switches & Pilot Devices A3 Assembled Selector Switches A S W 3 (1) (L) 20 (N) - 304 Circuit Number Function S: Selector Switch (Standard circuits shown on following pages and A3-150.) Series Designation W: TW Series Contacts Terminal Style Blank: standard N: Fingersafe (IP20) Number of Positions 2: 2-Position 3: 3-Position 4: 4-Position 5: 5-Position Contact Arrangement Code 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC Spring Return Action Blank: Maintained 1: Spring return from Right (2 or 3 position) 2: Spring return from Left (2 or 3 position) 3: 2-Way spring return from Left and Right (3 position only) Operator Style Code Blank: Knob Operator L: Lever Operator K: Key Operator 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. 3. Portions of part number inside ( ) are optional. A3-142 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Assembled) con’t Part Numbers: 2–Position Selector Switches Style Part Number Part Number Spring Return from Left Mounting Spring Return from Right Contact Operator Position Part Number 1NO 1 2 O O X O Knob Lever Key ASW210 ASW2L10 ASW2K10 ASW2110 ASW21L10 ASW21K10 ASW2210 ASW22L10 ASW22K10 1NC 1 2 X O O O Knob Lever Key ASW201-116 ASW2L01-116 ASW2K01-116 ASW2101-116 ASW21L01-116 ASW21K01-116 ASW2201-116 ASW22L01-116 ASW22K01-116 1NO 1NC 1 2 X O O X Knob Lever Key ASW211 ASW2L11 ASW2K11 ASW2111 ASW21L11 ASW21K11 ASW2211 ASW22L11 ASW22K11 2NO 1 2 O O X X Knob Lever Key ASW220 ASW2L20 ASW2K20 ASW2120 ASW21L20 ASW21K20 ASW2220 ASW22L20 ASW22K20 2NC 1 2 X X O O Knob Lever Key ASW202-104 ASW2L02-104 ASW2K02-104 ASW2102-104 ASW21L02-104 ASW21K02-104 ASW2202-104 ASW22L02-104 ASW22K02-104 2NO 2NC 1 2 3 4 O X O X X O X O Knob Lever Key ASW222 ASW2L22 ASW2K22 ASW2122 ASW21L22 ASW21K22 ASW2222 ASW22L22 ASW22K22 2NO 2NC 1 2 3 4 O O X X X X O O Knob Lever Key ASW222-111 ASW2L22-111 ASW2K22-111 ASW2122-111 ASW21L22-111 ASW21K22-111 ASW2222-111 ASW22L22-111 ASW22K22-111 L R Maintained L R L Operator Position Part Number Spring Return from Left Spring Return Two-Way Mounting Spring Return from Right Part Number Contact Maintained Part Number A3 R Switches & Pilot Devices Part Numbers: 3–Position Selector Switches Style Part Number L R L 2NO 1 2 X O O O O X Knob Lever Key ASW320 ASW3L20 ASW3K20 ASW3120 ASW31L20 ASW31K20 ASW3220 ASW32L20 ASW32K20 ASW3320 ASW33L20 ASW33K20 2NC 1 2 O X X X X O Knob Lever Key ASW302 ASW3L02 ASW3K02 ASW3102 ASW31L02 ASW31K02 ASW3202 ASW32L02 ASW32K02 ASW3302 ASW33L02 ASW33K02 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Knob Lever Key ASW322 ASW3L22 ASW3K22 ASW3122 ASW31L22 ASW31K22 ASW3222 ASW32L22 ASW32K22 ASW3322 ASW33L22 ASW33K22 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Knob Lever Key ASW322-309 ASW3L22-309 ASW3K22-309 ASW3122-309 ASW31L22-309 ASW31K22-309 ASW3222-309 ASW32L22-309 ASW32K22-309 ASW3322-309 ASW33L22-309 ASW33K22-309 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Knob Lever Key ASW322-310 ASW3L22-310 ASW3K22-310 ASW3122-310 ASW31L22-310 ASW31K22-310 ASW3222-310 ASW32L22-310 ASW32K22-310 ASW3322-310 ASW33L22-310 ASW33K22-310 4NO 1 2 3 4 X O X O O O O O O X O X Knob Lever Key ASW340 ASW3L40 ASW3K40 ASW3140 ASW31L40 ASW31K40 ASW3240 ASW32L40 ASW32K40 ASW3340 ASW33L40 ASW33K40 4NC 1 2 3 4 O X O X X X X X X O X O Knob Lever Key ASW304 ASW3L04 ASW3K04 ASW3104 ASW31L04 ASW31K04 ASW3204 ASW32L04 ASW32K04 ASW3304 ASW33L04 ASW33K04 www.idec.com C C R L R C L C C R L R L R USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Every key selector switch uses an identical key. The key is removable in any maintained position. If a different configuration is required, contact an IDEC representative for more information. 4. Custom contact configurations are available, see page A3-150 or contact IDEC for details. A3-143 Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Assembled) con’t Part Numbers: 4–Position Selector Switch Maintained Part Number Contact 1 1 2 3 4 X O O O 2NO 2NC 2 3 4 2 1 3 4 O X O O O O X O O O O X Knob Lever ASW422-411 ASW4L22-411 Part Numbers: 5–Position Selector Switch Maintained Part Number Mounting Operator Position Contact Switches & Pilot Devices A3 Mounting Operator Position 1 1 2 3 4 X O O O 2NO 2NC A3-144 2 3 4 5 2 1 O X O O O O O O O O X O O O O X Knob Lever www.idec.com 3 4 5 ASW522-501 ASW5L22-501 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever * + Color Insert * Complete Part † = A3 Switches & Pilot Devices 1. * Not needed with key type switches. 2. † Knob type shown. Part Numbers: Operators Style Positions Description 2 Knob/Lever 3 4 5 2 Key 3 Part Number Maintained Spring return from right Spring return from left Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 Spring return from right, Cam 1 Spring return from right, Cam 2 Spring return from left, Cam 1 Spring return from left, Cam 2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 Maintained, Standard Cam Maintained, Cam 1 Maintained, Standard cam Maintained, Cam 1 ASW200 ASW2100 ASW2200 ASW300-1 ASW300-2 ASW300-3 ASW3100-1 ASW3100-2 ASW3200-1 ASW3200-2 ASW3300-1 ASW3300-2 ASW400 ASW400-1 ASW500 ASW500-1 Maintained Spring return from right Spring return from left Maintained, Cam 1 Maintained, Cam 2 Maintained, Cam 3 Spring return from right, Cam 1 Spring return from right, Cam 2 Spring return from left, Cam 1 Spring return from left, Cam 2 Spring return from left/right, Cam 1 Spring return from left/right, Cam 2 ASW2K00 ASW21K00 ASW22K00 ASW3K00-1 ASW3K00-2 ASW3K00-3 ASW31K00-1 ASW31K00-2 ASW32K00-1 ASW32K00-2 ASW33K00-1 ASW33K00-2 1. Two keys are supplied with every switch, all are keyed alike, and removable from any maintained position. For other configurations, consult your IDEC representative. 2. Locking rings are included with all operators. Order knobs, levers, and color inserts separately. 3. Different cams produce different contact actions. For details, see contact arrangement charts, page A3-150. Part Numbers: Handles and Inserts Style Part Number Knob ASWHHY-① Lever ASWHHL-① Color Insert TW-HC1-① Part Numbers: Contact Blocks Style Part Number 1NO 1NC Standard HW-C10 HW-C01 HW-C10R (early make) HW-C01R (late break) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Fingersafe (IP20) Dummy Block TW-DB ① Handle/Insert Color Code Color Code Black* B Blue S Green G Red R Yellow Y White† W 1. Push rod color code:Green = NO contact block Red = NC contact block. 2. Dummy blocks (no contacts) are used with an odd number of contact blocks. * Color inserts not available in black. † Knob and lever not available in white. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-145 Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Assembled) Switches & Pilot Devices A3 Assembled Illuminated Selector Switches A SL W 2 (2) 99 11 (D) (N) - (202) - R - (24V) Function SL: Illuminated Selector Switch Lamp Voltage (Full Voltage Units Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC (LED only) 240V: 240V AC (LED only) Series Designation W: TW Series Number of Positions 2: 2-Position 3: 3-Position Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: Two-Way spring return from Left & Right Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Illumination Circuit 99: Full Voltage (lamp determines voltage) 126: 120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer Contact Circuit No. Standard circuits are listed on the following pages and A3-150. Contacts Terminal Style Blank: standard N: Fingersafe (IP20) Lamp Type Blank: Incandescent D: LED Contact Arrangement Code 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers step down to 6V (use 6V lamp). A3-146 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Assembled) con’t Contact Operator Position L R Spring Return from Right Maintained Lamp Circuit Type L ➀ Transformer Voltage Code Spring Return from Left R L L R R Code 120V AC 126 240V AC 246 480V AC 486 A3 Transformers step down to 6V (use 6V lamp). 1NO 1NC 1 2 O X X O Transformer Full Voltage ASLW2 ➀ 11➃-➁ ASLW29911➃-➁-➂ ASLW21 ➀ 11➃-➁ ASLW219911➃-➁-➂ ASLW22 ➀ 11➃-➁ ASLW229911➃-➁-➂ 2NO 1 2 O O X X Transformer Full Voltage ASLW2 ➀ 20➃-➁ ASLW29920➃-➁-➂ ASLW21 ➀ 20➃-➁ ASLW219920➃-➁-➂ ASLW22 ➀ 20➃-➁ ASLW229920➃-➁-➂ 2NC 1 2 X X O O Transformer Full Voltage ASLW2 ➀ 02➃-104-➁ ASLW21 ➀ 02➃-104-➁ ASLW29902➃-104-➁-➂ ASLW219902➃-104-➁-➂ 1 2 3 4 O X O X X O X O Transformer Full Voltage ASLW2 ➀ 22➃-➁ ASLW29922➃-➁-➂ 2NO 2NC Voltage ASLW21 ➀ 22➃-➁ ASLW219922➃-➁-➂ ➁ Lens Color Code Color Code Color ASLW22 ➀ 02➃-104-➁ ASLW229902➃-104-➁-➂ Amber A Blue S Green G White W ASLW22 ➀ 22➃-➁ ASLW229922➃-➁-➂ Red R Yellow Y Part Numbers: Illuminated 3–Position Selector Switches Maintained and Spring Return from Right Style Part Number Part Number Part Number Operator Position Spring Return From Right Part Number Spring Return Two-Way Mounting Spring Return from Left Contact Maintained Code L 2NO 1 2 X O O O O X Transformer Full Voltage ASLW3 ➀ 20➃-➁ ASLW39920➃-➁-➂ ASLW31 ➀ 20➃-➁ ASLW319920➃-➁-➂ ASLW32 ➀ 20➃-➁ ASLW329920➃-➁-➂ ASLW33 ➀ 20➃-➁ ASLW339920➃-➁-➂ 2NC 1 2 O X X X X O Transformer Full Voltage ASLW3 ➀ 02➃-➁ ASLW39902➃-➁-➂ ASLW31 ➀ 02➃-➁ ASLW319902➃-➁-➂ ASLW32 ➀ 02➃-➁ ASLW329902➃-➁-➂ ASLW33 ➀ 02➃-➁ ASLW339902➃-➁-➂ 2NO 2NC 1 2 3 4 X O O X O O X X O X X O Transformer Full Voltage ASLW3 ➀ 22➃-➁ ASLW39922➃-➁-➂ ASLW31 ➀ 22➃-➁ ASLW319922➃-➁-➂ ASLW32 ➀ 22➃-➁ ASLW329922➃-➁-➂ ASLW33 ➀ 22➃-➁ ASLW339922➃-➁-➂ 2NO 2NC 1 2 3 4 X X O O O X X O X O O X Transformer Full Voltage ASLW3 ➀ 22➃-309-➁ ASLW39922➃-309-➁-➂ ASLW31 ➀ 22➃-309-➁ ASLW319922➃-309-➁-➂ ASLW32 ➀ 22➃-309-➁ ASLW329922➃-309-➁-➂ ASLW33 ➀ 22➃-309-➁ ASLW339922➃-309-➁-➂ 2NO 2NC 1 2 3 4 O O O O X O X O O X O X Transformer Full Voltage ASLW3 ➀ 22➃-310-➁ ASLW39922➃-310-➁-➂ ASLW31 ➀ 22➃-310-➁ ASLW319922➃-310-➁-➂ ASLW32 ➀ 22➃-310- ➁ ASLW329922➃-310- ➁ -➂ ASLW33 ➀ 22➃-310-➁ ASLW339922➃-310-➁-➂ 4NO 1 2 3 4 X O X O O O O O O X O X Transformer Full Voltage ASLW3 ➀ 40➃-➁ ASLW39940➃-➁-➂ ASLW31 ➀ 40➃-➁ ASLW319940➃-➁-➂ ASLW32 ➀ 40➃-➁ ASLW329940➃-➁-➂ ASLW33 ➀ 40➃-➁ ASLW339940➃-➁-➂ 4NC 1 2 3 4 O X O X X X X X X O X O Transformer Full Voltage ASLW3 ➀ 04➃-➁ ASLW39904➃-➁-➂ ASLW31 ➀ 04➃-➁ ASLW319904➃-➁-➂ ASLW32 ➀ 04➃-➁ ASLW329904➃-➁-➂ ASLW33 ➀ 04➃-➁ ASLW339904➃-➁-➂ C R Lamp Circuit Type 1. In place of ➀, specify the Transformer Voltage Code. 2. In place of ➁, specify the Lens/LED Color Code. 3. In place of ➂, specify the Full Voltage Code. 4. In place of ➃ specify Lamp Type Code 5. For custom contact configuration, see page A3-150. Contact IDEC for details. www.idec.com C L C R L R ➂ Full Voltage Code C L C R L R ➃ Lamp Type Code Voltage Code Lamp Code 6V AC/DC 6V Incandescent Blank 12V AC/DC 12V LED D 24V AC/DC 24V 120V AC 120V (LED only) 240V AC 240V (LED only) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-147 Switches & Pilot Devices Mounting Part Numbers: Illuminated 2–Position Selector Switches Style Part Number Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp/Lead Holder † + Lamp + Lens = Complete Part Switches & Pilot Devices A3 1.* Full voltage units use a full voltage adaptor (TW-DA1B) instead of a transformer. 2. † Lamp holder is not included with operators, order separately. Lead holder is used when using 3 or more contact blocks. Order separately. Part Numbers: Operators Positions 2 3 Part Number Description Maintained ASLW200 Spring return from right ASLW2100 Spring return from left ASLW2200 Maintained, cam 1 Maintained, cam 2 Maintained, cam 3 ASLW300-1 ASLW300-2 ASLW300-3 Spring return from right, cam 1 Spring return from right, cam 2 ASLW3100-1 ASLW3100-2 Spring return from left, cam 1 Spring return from left, cam 2 ASLW3200-1 ASLW3200-2 Spring return from left/right, cam 1 Spring return from left/right, cam 2 ASLW3300-1 ASLW3300-2 Part Numbers: Lamps (LED) Type Voltage LED Incandescent Knob ASLWLU-➁ In place of ➁ specify Lens Color Code. A3-148 www.idec.com 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 1. In place of ➁, specify the LED Color Code. 2. The LED contains a current-limiting resistor and a protection diodes. Different cams produce different contact action. For details, Contact Arrangements on page A3-150. Part Numbers: Lenses (Knobs) Description Part Number Part Number ➁ LED/Lens Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Illuminated Selector Switches (Sub-Assembled) con’t Part Numbers: Contact Blocks Description Part Numbers: Transformers/Full Voltage Modules Style Description Part Number Part Number 1NO 1NC Full Size Transformer Standard HW-C01 HW-C10R (early make) HW-C01R (late break) Fingersafe Half Size Transformer 120V AC 240V AC 480V AC 120V AC 240V AC 480V AC TW-T126B TW-T246B TW-T486B TW-F126B TW-F246B TW-F486B 120V AC TW-T126SB 240V AC TW-T246SB Standard TW-DA1B Fingersafe TW-DA1FB Standard HW-DA1B Fingersafe HW-DA1FB Fingersafe (IP20) HW-F10 HW-F01 HW-F10R (early make) HW-F01R (late break) Full voltage model (use with even number of contacts) Dummy Block TW-DB Full voltage model (use with odd number of contacts) 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Use of early and late break contacts creates a make before break function All Transformers step down to 6V (use 6V lamp). Part Numbers: Lamp Circuit Components Style Application Part Number Short Lamp Holder Long Lamp Holder Used with a Half-size Transformer and one contact block TW-LH1 Used with a Full-size Transformer and two contact blocks Used w/Half-size Transformer and three contact blocks Used w/Full Voltage Adaptor and two contact blocks TW-LH2 Used w/TW-LH2 holder when using four contact blocks HW-LH3 Lead Holder www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-149 A3 Switches & Pilot Devices HW-C10 Standard Oiltight Switches & Pilot Devices ø22mm - TW Series Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Switches & Pilot Devices A3 Contact Arrangement Mounting Positions Type and quantity of switch contacts Circuit Number L R 4 2 3 * N/D = No designation required 1 Contact Block Mounting Position Position or mounting contact blocks on operator Operator Position Truth table indicates the operating position of contact block when operator is switched to that position. Contact Block Part Number Part number to use when ordering subassembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-Position Selector Switches Style Mounting Operator Contact Block Description Circuit Position Position Part Number Contact Number L R Operator Part Number Spring Ret. Spring Ret. Maintained from Rt. from Lt. L 1NO N/D 1NC 116 N/D 1NO 1NC 103 600 1NO-EM 1NC-LB 601 2NO N/D 2NC 104 N/D 2NO 2NC 111 1 O X HW-C10 2 O O TW-DB 1 X O HW-C01 2 O O TW-DB 1 O X HW-C10 2 X O HW-C01 1 X O HW-C01 2 O X HW-C10 1 O X HW-C10R 2 X O HW-C01R 1 X O HW-C01R 2 O X HW-C10R 1 O X HW-C10 2 O X HW-C10 1 X O HW-C01 2 X O HW-C01 1 2 3 4 1 2 3 4 O X O X O O X X X O X O X X O O HW-C10 HW-C01 HW-C10 HW-C01 HW-C10 HW-C10 HW-C01 HW-C01 R L R L R Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 Knob/Lever Key Illuminated Knob ASW200 ASW2K00 ASLW200 ASW2100 ASW21K00 ASLW2100 ASW2200 ASW22K00 ASLW2200 1. NO-EM, NC-LB = Early Make, Late Break. N/D = No circuit number designation required in assembled selector switch part number. 2. X = On (closed contacts) O = Off (Open contacts) A3-150 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices Contact Arrangement Chart: 3-Position Selector Switches Style Mounting Operator Contact Block Circuit Position Position Part Number Contact Number L C Description Maintained R 1NO 1NC 302 303 N/D 2NO 301 304 2NC N/D N/D 210 2NO 2NC 308 309 310 N/D 4NO 305 N/D 4NC 314 1 X 0 0 HW-C10 2 X X O HW-C01 1 0 X X HW-C01 2 O 0 X HW-C10 1 X 0 X HW-C10 2 X X O HW-C01 1 0 X O HW-C01 2 O 0 X HW-C10 1 X 0 0 HW-C10 2 O 0 X HW-C10 1 X 0 X HW-C10 2 O 0 X HW-C10 1 0 X O HW-C01 2 X X O HW-C01 1 0 X X HW-C01 2 X X O HW-C01 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 X 0 0 X 0 0 0 0 X X X X X X 0 O 0 O 0 0 X 0 X 0 X 0 X 0 0 X 0 X 0 X 0 X 0 0 X X X 0 X 0 0 X 0 X 0 X X 0 X 0 X 0 0 0 0 0 0 0 0 0 X X X X X X X X 0 X X 0 X X X X X 0 X O X 0 O X O X O X 0 X 0 X X X X X X 0 X O O 0 O 0 HW-C10 HW-C10 HW-C01 HW-C01 HW-C01 HW-C10 HW-C01 HW-C10 HW-C10 HW-C01 HW-C10 HW-C01 HW-C10 HW-C01 HW-C01 HW-C10 HW-C01 HW-C10 HW-C01 HW-C10 HW-C10 HW-C10 HW-C10 HW-C10 HW-C10 HW-C10 HW-C10 HW-C10 HW-C01 HW-C01 HW-C01 HW-C01 HW-C01 HW-C01 HW-C01 HW-C01 C R L Two-Way C C R L R L R Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 A3 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Switches & Pilot Devices 203 Operator Part Number Spring Ret. Spring Ret. from Rt. from Lt. C L 202 ø22mm - TW Series Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 Knob/Lever Key Illuminated Knob ASW300-1 ASW3K00-1 ASLW300-1 ASW3100-1 ASW31K00-1 ASLW3100-1 ASW3200-1 ASW32K00-1 ASLW3200-1 ASW3300-1 ASW33K00-1 ASLW3200-1 Knob/Lever Key Illuminated Knob ASW300-2 ASW3K00-2 ASLW300-2 ASW3100-2 ASW31K00-2 ASLW3100-2 ASW3200-2 ASW32K00-2 ASLW3200-2 ASW3300-2 ASW33K00-2 ASLW3200-2 1. Each operator sub-assembly is available as a “-1" and a “-2" for 3-position selector switches. The internal cam of a “-1" is different from that of a “-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-151 Oiltight Switches & Pilot Devices ø22mm - TW Series Custom Selector Switch Building Guide To build a custom selector switch, follow these steps. Step1: How many positions of the switch are needed? # of positions (2, 3, 4, 5) Switches & Pilot Devices A3 Mounting Positions L R 4 2 3 Step 2: How many contacts should there be? # of isolated contacts (maximum 6) 1 Step 3: Fill in the Truth Table (X = closed, O = open) Knob Position 1 2 3 4 5 1 C o n t a c t s 2 3 4 5 6 Step 4: If building a 2 position selector, skip this step. (2 position selectors have only one cam) If building a 3, 4, or 5 position selector, determine appropriate cam as follows: -Look at Row 1 from above table and locate an identical row in the operator truth tables (See next page). -Repeat for all rows. The user must find one operator that contains all rows from above table. -Record the operator cam version. Operator CAM Version (-1, -2, -3 for 3 position) (“blank”, -1 for 4 position) (“blank”, -1 for 5 position) Step 5: Build by placing appropriate contact in appropriate mounting position for each desired row on operator cam truth table. “L” and “R” refer to mounting on left or right side of operator as viewed from the front of the panel. Step 6: Develop an assembly part number (if necessary) as follows: follow standard numbering nomenclature for selector switches (see pages A3-142 or A3-146). In place of the “Circuit Number” indicate the cam number and contact arrangement as such ASW322-3-OELCSS, where “3” is the cam number, and contact arrangement “OELCXX” calls out individual contact mounting locations in order (see diagram above). O=NO, C=NC, E=NO-EM, L=NC-LB, X= no contact. Part number must designate all 6 possible mounting locations. Caution: Before putting any custom selector switch into use, the user should use an ohmmeter to test for desired performance. 1. For Operator Truth Tables, see next page. 2. For examples of how to assemble selector switches, see A3-82. A3-152 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches 4 Position Selector Switches Mounting Operator Position Contact Position Left Right ASW200 ASLW200 ASW2K00 HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) L O X R O X L X O R X O L 0 X R O X L X O R X O Contact HW-C10 (NO) ASW300-1 ASW3K00-1 ASLW300-1 HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) 1 2 3 4 L X O O O R O X O O L O X X X R X O X X L X O O O R O X O O L O X X X R X O X X HW-C10 (NO) HW-C01 (NC) ASW400 HW-C10R (NO-EM) HW-C01R (NC-LB) 3 Position Selector Switches L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O A3 Operator Position Mounting Position Contact Mounting Operator Position Position Left Center Right Operator Position Mounting Position 1 2 3 4 HW-C10 (NO) L X O O O R O O O X HW-C01 (NC) L O O X O R O X O O HW-C10R (NO-EM) L X X O X R X O X X HW-C01R (NC-LB) L O X X X R X X X O ASW400-1 Switches & Pilot Devices HW-C10 (NO) Contact 5 Position Selector Switches Contact ASW300-2 ASW3K00-2 ASLW300-2 Mounting Position Left Center Right HW-C10 (NO) L X O X R O O X HW-C01 (NC) L O X O R X X O HW-C10R (NO-EM) L X O X R O O X HW-C01R (NC-LB) L O X O R X X O Contact HW-C10 (NO) ASW300-3 ASW3K00-3 ASLW300-3 Operator Position HW-C01 (NC) HW-C10R (NO-EM) HW-C01R (NC-LB) www.idec.com Contact L X O O R O O X L O X O R O X O L X O X R X O X L O X X R X X O Operator Position 1 2 3 4 5 HW-C10 (NO) L X O O O O R O X O O O HW-C01 (NC) L O O X X X R O O O X X HW-C10R (NO-EM) L X O O O O R O X O O O HW-C01R (NC-LB) L O X X X X R X O X X X ASW500 Mounting Operator Position Position Left Center Right Mounting Position Contact HW-C10 (NO) HW-C01 (NC) ASW500-1 HW-C10R (NO-EM) HW-C01R (NC-LB) Operator Position Mounting Position 1 2 3 4 5 L X O O O O R O O O O X L O O O X O R O X O O O L X X X O X R X O X X X L O X X X X R X X X X O USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-153 Oiltight Switches & Pilot Devices ø22mm - TW Series Nameplates — TW Series Part Numbers: Nameplates NWAL NWAQL A3 NWAS 1.13" (29mm) 1.76" (45mm) Ø 70 1.76" (45mm) (25mm) 0.975" 0.566" (14.5mm) 1.0" Part Number GENC ER M E Y (25.4mm) 1.13" (29mm) Switches & Pilot Devices EMERGENCY STOP ST OP Yellow Part Number Part Number Part Number Nameplate (blank) NWAL-OB (black) NWAL-OR (red) NWAQL-OB (black) NWAQL-OR (red) NWAS-OB NWAR-O Nameplate (engraved) NWAL-➀ NWAQL-➀ NWAS-➀ NWAR-27† 1. In place of ➀, insert either the Standard Legend Code from table below or custom engraving delimited by “ “. 2. Standard engravings are available at no charge. 3 NWAR-27 comes marked “Emergency Stop” as shown in drawing. Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Legend Code Legend Code Legend Code AUTO CLOSE DOWN EMERG.STOP* FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 OPEN OUT RAISE RESET REVERSE RUN SLOW START STOP* STOP TEST UP I (Int’l On) O (Int’l Off) EMO 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 Legend REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Selector Switches Code Legend Code 216 217 218 219 220 221 222 223 AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. To order engraved nameplates, add legend code to nameplate part number. Character height based on the number of characters and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. 3. * Available in red as standard. Nameplate Order Form on next page. A3-154 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Custom Engraved Nameplates Order Form — TW Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative. or Distributor. Your Company Name: IDEC Rep/Distributor Contact: Your Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: Fax & Email IDEC Rep/Distributor Fax & Email A3 Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) 1/8” Letter Size 9 characters max (for 1/8” size letters) Sample Letter Sizes 7/64” Letters: A B C D 1/8” Letters: A B C D Qty 1 2 3 4 5 6 7 8 9 10 11 NWAQL Engraving Location Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 9 characters. Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 7/64” Letter Size 11 characters max (for 7/64” size letters) 1/8” Letter Size 9 characters max (for 1/8” size letters) Sample Letter Sizes 7/64” Letters: A B C D 1/8” Letters: Qty 1 2 3 4 5 6 7 ABCD 8 9 10 11 NWAS Engraving Location A Step 1. Choose Letter Size - 1/8” or 3/32”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 14 characters. 3/32” Letter Size 1/8” Letter Size 20 characters maximum (for 3/32” size letters) 14 characters maximum (for 1/8” size letters) Engraving Location B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Step 2. Specify Quantity. Enter the number of nameplates desired in box on the right. www.idec.com Qty Step 3. Specify Location. Enter the location of engraving (A or B), in box on the right. Sample Letter Sizes 3/32” Letters: A B C D 1/8” Letters: A B C D Location USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-155 Switches & Pilot Devices NWAL ø22mm - TW Series Oiltight Switches & Pilot Devices Accessories — TW Series Part Numbers: TW Series Accessories Appearance Switches & Pilot Devices A3 Description/Usage Part Number Lamp Removal Tool Rubber tool used to install LED’s and incandescent lamps OR-55 Contact Block Remover Used to remove contact blocks, transformers, lenses, and adaptors. Can also be used to determine panel thickness adjustment. TW-KC1 Nut Locking Wrench Used in OR-14 locking wrench to tighten locking nuts inside square bezel TW-KQ2 Metal Bezel Chrome plated bezels tighten onto operator (replacement for damaged bezels) Black plastic bezels for square buttons (replacement for damaged bezels) Plastic Bezel Used to cover and protect pushbuttons Boot/Cover Standard octagonal units (chrome-pl.) AW-R8 Full shroud octagonal units (chrome-pl.) AW-RF8 Full shroud (chrome plated) mushroom head units Ø 40mm AW-G4 Round flush units (black plastic) AW-RP1B Round extended units (black plastic) AW-FP1B Square units (black plastic) AW-Q1B Square bezel with round hole (black plastic) AW-H1B Square units with full shroud (black plastic) AW-QF1B Waterproof lens cover for square pilot lights APW00LN Waterproof lens cover for square illuminated buttons APW00L Clear boot for round flush units (EPR) OC-31 Clear boot for round extended units (EPR) OC-32 *In place of asterisk, specify Rubber Boot color: B (black), G (green), R (red), Y (yellow) - (nitril rubber) OCW-11* Ring to prevent operator base from rotating in the mounting hole. Anti-Rotation Ring OGL-31 Used when nameplate is not used Mounting Hole Plug Metallic Mounting Hole Plug Black rubber plug fills unused mounting holes in panel. OB-31 For plugging unused mounting holes in the panel. Tighten the attached locking ring to a torque of 12 kfg-cm maximum LW9Z-BM Degree of protection: IP66 Replacement Keys Pair of keys (#0) TW-SK For information on replacement engraving inserts, see page A3-164. A3-156 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Accessories con’t Part Numbers: TW Series Accessories Appearance Description/Usage Part Number Metal Button Guard OLW-C Quick- connect terminals TW-FA1 A3 Switches & Pilot Devices Used on flush buttons to prevent inadvertent actuation Terminal Tab Adaptor #250 (17/64" x 3/64") single tab Lock-out Adaptor Used to provide lock-out protection for pushbuttons and knob selector switches: • Up to Ø 40mm mushroom head size (Padlock not included.) HW9Z-KL1 Used to mount TW series control unit (except square units) Ø 7/8" (22mm) into a Ø 1-13/64" (30mm) panel cut-out. Includes 2 pieces shown on the right TWN-A1R8 TW to TWTD Adaptor Adaptor Fits on TW unit base Replacement Marking Plates Round Pushbutton (Ø14mm) White plastic engraving plate for use on all illuminated units (included in each lens). May be used to capture printed mylar insert (not supplied by IDEC) under lens face. HW-VL3 APS-PVL Part Numbers: Fingersafe Covers for TW Series Appearance Description HW VL6 HW VL5 www.idec.com ALW2B Round Pilot Light (Ø 14mm) APW2B Mushroom Pushbutton (Ø 14mm) ALW3B Square Pilot Light (❑ 21mm) APQW1B Square Pushbutton (❑ 21mm) ALQW2B Used with Part Number Fingersafe terminal cover, adds 6mm to overall depth APW and UPQW full voltage pilot lights APS-PVL Fingersafe terminal cover, adds 3.5mm to overall depth. One required for each contact, only for rear- most terminals Non-illuminated pushbuttons and selectors HW-VL2 Fingersafe terminal cover, adds 3mm to overall depth APW and UPQW transformer pilot lights, and illuminated pushbuttons and illuminated selectors HW-VL3 Fingersafe terminal cover for contacts. Full voltage illuminated pushbuttons and selectors HW-VL4 Fingersafe terminal cover for full voltage adaptor, adds 3 mm to depth Full voltage illuminated pushbuttons and selectors HW-VL5 Fingersafe terminal cover for half size transformer adaptor, adds 3 mm to depth Illuminated pushbuttons and selectors HW-VL6 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-157 Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions — TW Series Pushbuttons 22.5 37 37 ø24 ø29 ø46 Keylock Push On/Off Panel Thickness: 1 to 6 mm Resetting (Unlock) M3.5 Terminal Screw Panel Thickness: 1 to 6 mm Resetting angle 75° ø40 Resetting angle 75° 30 23 45° ø29 M3.5 Terminal Screw Panel Thickness: 1 to 6 mm ø29 48.5 (2 blocks) 68.5 (4 blocks) 30 40mm Push-Lock-Turn-Reset 29mm Push-Lock-Turn-Reset M3.5 Terminal Screw 13 68.5 (4 blocks) 30 Panel Thickness: 1 to 6 mm 37 ø40 37 48.5 (2 blocks) 13 22.5 M3.5 Terminal Screw Panel Thickness: 1 to 6 mm 37 M3.5 Terminal Screw ø29 48.5 (2 blocks) 68.5 (4 blocks) Mushroom with Full Shroud 40mm Mushroom Panel Thickness: 1 to 6 mm 30 68.5 (4 blocks) 30 37 M3.5 Terminal Screw 19 37 29mm Mushroom 19.5 48.5 (2 blocks) 13 68.5 (4 blocks) Panel Thickness: 1 to 6 mm 37 ø24 30 M3.5 Terminal Screw Panel Thickness: 1 to 6 mm 37 ø29 48.5 (2 blocks) 13 68.5 (4 blocks) 13 48.5 (2 blocks) M3.5 Terminal Screw Panel Thickness: 1 to 6 mm 13 13 25 48.5 (2 blocks) 47 68.5 (4 blocks) Square Flush Panel Thickness: 1 to 6 mm 37 ø40 45° 30 37 M3.5 Terminal Screw 30 Panel Thickness: 1 to 6 mm Resetting (Unlock) 47 68.5 (4 blocks) 30 40mm Push-Pull 40mm Pushlock Key Reset M3.5 Terminal Screw 22.5 25 25 68.5 (4 blocks) 30 22.5 48.5 (2 blocks) 13 37 68.5 (4 blocks) 48.5 (2 blocks) 13 ø40 48.5 (2 blocks) 68.5 (4 blocks) 30 25 48.5 (2 blocks) 30 30.5 13 30 68.5 (4 blocks) Square Extended Panel Thickness: 1 to 6 mm 48.5 (2 blocks) 68.5 (4 blocks) 37 30 M3.5 Terminal Screw 25 13 30 20 Selector Switches 68.5 (4 blocks) A3-158 13 25 30 www.idec.com 48.5 (2 blocks) 68.5 (4 blocks) 48.5 (2 blocks) 13 25 30 68.5 (4 blocks) 37 37 ø29 37 ø25 48.5 (2 blocks) Panel Thickness 1 to 6 mm ø29 M3.5 Terminal Screw Panel Thickness 1 to 6 mm ø24 M3.5 Terminal Screw Panel Thickness: 1 to 6 mm ø29 M3.5 Terminal Screw ø24 Switches & Pilot Devices 48.5 (2 blocks) Extended with Full Shroud M3.5 Terminal Screw Panel Thickness: 1 to 6 mm ø24 A3 Extended M3.5 Terminal Screw ø29 Flush 13 19 41 30 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Illuminated Pushbuttons Extended Extended with Full Shroud 30 37 Marking Plate: ø15.5 mm Marking Plate: ø15.5 mm Square Extended 29mm Push-Turn Reset Panel Thickness: 1 to 6 mm Resetting Angle: 75° Panel Thickness: 1 to 6 mm 13 21 mm Ø 1.13" (29mm) Ø 1.56" (40mm) Ø 1.56" (40mm) Ø 1.56" (40mm) Push-Pull Mushroom Panel Thickness: 1 to 6 mm 37 13 13 30 13 30 25 22.5 Marking Plate: ø13.9 mm Marking Plate: ø13.9 mm 1 Contact Block with Half Size Transformer Transformer (2 blocks) Panel Thickness: 1 to 6 mm M3.5 Terminal Screw X1 30 30.5 Marking Plate: ø13.9 mm Illuminated Selector Switches 1 Contact Block with Full Voltage Adaptor 37 37 ø29 Panel Thickness: 1 to 6 mm ø40 Panel Thickness: 1 to 6 mm Resetting angle: 75° ø40 0.858" (22mm) 0.858" (22mm) *0.936" (24mm) † 0.975" (25mm) Marking Plate: ø13.9 mm 40mm Push-Turn Reset M3.5 Terminal Screw 0.761" (19.5mm) Ø 0.936" (Ø24mm) ❏0.975" (❏25mm) 30 22.5 Marking Plate: 22.5 0.741" (19mm) 13 30 20 Dimension B 1. * Dimension when operator is in reset position. 2. † Dimension when operator is in pull position. 37 ø29 37 30 25 ø29 ø24 ø29 ø24 37 30 20 Dimension A Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm X1 X1 X2 X2 X2 48.5 86.5 64.5 2 Contact Blocks with Full Voltage Adaptor M3.5 Terminal Screw 2 Contact Blocks with Half Size Transformer Transformer (4 blocks) M3.5 Terminal Screw X1 Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 m Panel Thickness: 1 to 6 mm X1 X1 X2 X2 X2 106.5 63.5 68.5 4 Contact Blocks with Full Voltage Adaptor 3 Contact Blocks with Full Voltage Adaptor M3.5 Terminal Screw Panel Thickness: 1 to 6 mm M3.5 Terminal Screw 3 Contact Blocks with Half Size Transformer Panel Thickness: 1 Panel Thickness: 1 to 6 mm X1 X1 X1 X2 X2 X2 68.5 83.5 M3.5 Terminal Screw 84.5 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-159 A3 Switches & Pilot Devices 13 19 Illuminated Pushbuttons Extended (Same for Square) w/Full Shroud Ø 1.13" (29mm) Mushroom Ø 1.56" (40mm) Mushroom, Pushlock Turn Reset, Push-Pull Panel Thickness: 1 to 6 mm Panel Thickness: 1 to 6 mm Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Pilot Lights Round Flush APW1 Full Voltage 30 28.5 28.5 37 30 Marking plate: ø15.5 mm Dome APW2 Transformer 30 28.5 66.5 Square Flush Marking Type APQW1B Full Voltage Panel Thickness 1 to 6 30 25 Square Flush Marking Type APQW1B Transformer M3.5 Terminal Screw 25 Panel Thickness 1 to 6 37 30 13 13 30 16 28.5 Marking plate: 66.5 22 mm 13 37 25 37 ø23.6 37 13 ø29 Panel Thickness 1 to 6 M3.5 Terminal Screw ø29 ø23.6 Panel Thickness 1 to 6 25 13 17 66.5 37 ø24 30 Marking plate: ø15.5 mm Dome APW2 Full Voltage 28.5 Panel Thickness 1 to 6 37 13 17 28.5 Round Flush Marking Type APW1B Transformer M3.5 Terminal Screw ø29 ø24 Panel Thickness 1 to 6 30 17 ø29 Round Flush Marking Type APW1B Full Voltage 28.5 13 66.5 17 ø29 ø24 37 13 30 28.5 Panel Thickness 1 to 6 M3.5 Terminal Screw ø29 ø24 A3 30 16 Marking plate: 22 mm Illuminated Selector Switches Panel Thickness: 1 to 6 mm A: 63.5 (2 blocks) 83.5 (4 blocks) B: 86.5 (2 blocks), 106.5 (4 blocks) A3-160 37 ø29 M3.5 Terminal Screw ø24 Switches & Pilot Devices Round Flush APW1 Transformer Panel Thickness 1 to 6 13 25 30 A: Rated voltage 24V AC/DC B: Rated voltage 100/110V AC, 200/220V AC www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Panel Cut-Out Diagram Dimensions Part A B C D Pushbuttons A Pilot Light Illuminated Pushbutton C B Ø 0.137" (3.5mm) Selector Switches 1.95" (50mm); 1.76" (45mm) minimum Ø 0.878" (22.3mm) 1.17" (30mm) *See note. Illuminated Selector Switches D 1.The Ø 0.137" (Ø 3.5mm) recess is necessary when either the nameplate or anti-rotation ring is used. 2. * >1.404" (36mm) for 2- or 3-position. >1.95" (50mm) for 4- or 5-position. Accessory Dimensions OGL-31 Anti-Rotation Ring OLW-C Metal Button Guard 0.398" (10.2mm) Minimum Mounting Centers 1.95" (50mm) Ø0.858" Ø1.07" (Ø27.4mm) (22mm) OCW-11 Pushbutton Rubber Boot Ø1.29" (Ø33mm) Ø0.897" (Ø23mm) OB-31 Mounting Hole Rubber Plug 0.137" (3.5mm) 0.429" (11mm) 0.741" (19mm) AW-RP1B Round Plastic Bezel 82.5 0.507" (13mm) Panel Thickness: 0.8 to 3.2 mm Ø1.13" (Ø29mm) 0.137" (3.5mm) Ø0.975" (Ø25mm) R1.66" (R42.5mm) HW9Z-KL1 (TW) Lock-out Adaptor Ø1.13" (Ø29mm) AW-FP1B Round Plastic w/Full Shroud 0.772" (19.8mm) R6 Ø1.13" (Ø29mm) 70 30 5 93 6. ID: 24 2 2. ø2 0 ø5 .4) 44 ø : (ID Lock Hole ø8 29.5 30 Waterproof Gasket 0.5t AW-QF1B Square Full Shroud AW-H1B Square Bezel w/ Round Hole 0.78" (20mm) ❏1.17" (❏30mm) www.idec.com 0.507" (13mm) ❏1.17" (❏30mm) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-161 A3 Switches & Pilot Devices 1.17" (30mm) Std. Octagonal > 1.56" (40mm) Large Mushroom Oiltight Switches & Pilot Devices ø22mm - TW Series Dimensions con’t Finger-Safe Cover Dimensions HW-VL6 0.69" (17.4mm) 1.57" (39.8mm) m ) 0.90" (22.8mm) 5" 5m 6. 0.34" (8.7mm) 0. 27 "( 0.61" (15.5mm) HW VL5 HW VL6 0.58" (14.8mm) 26 0. (7 m m ) 0.28" (7.2mm) 1.06" (27mm) 1.54" (39.1mm) 1.41" (10.4mm) 1.58" (40mm) HW-VL3 1.02" (26mm) A3-162 m (1.57" 39.8mm) .055" (14.1mm) 0.12" (3mm) 0.61" (15.5mm) www.idec.com 0.41" (10.4mm) .748" (19mm) 2" 12 ) 0. m R .1m (3 APS-PVL .271" (6.9mm) 8 .24 ) mm 6.3 "( 1.02" (26mm) .2 .244" (6.2mm) (6 APS-PVL HW-VL2 ) 1.42" (36mm) HW-VL3 4" m 0.79" (20mm) 2 0. 1.49" (37.8mm) Switches & Pilot Devices A3 HW-VL4 HW-VL5 .228" (5.8mm) .421" (10.7mm) 1.16" (29.4mm) USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Component Construction & Instructions — TW Series Lens or Button TW Series: Adjustment for Panel Thickness The panel thickness ring provides adjustment from 0.04" to 0.24" (1 to 6mm) in 0.004" (0.1mm) increments. Rotate the ring until the markings around the periphery are aligned for the desired thickness, as shown below. Adjustment 0mm 0.9mm 0.8mm 0.7mm 0.6mm 0.5mm 0.4mm 0.3mm (Round lens used on square pushbuttons and pilot lights only). Waterproof Gasket Adjustment Ring Panel Thickness) 0.2mm Waterproof Lens Examples Zero Point One Complete Revolution 0.1mm (Panel) 0mm Operator Zero Point 0.1mm panel thickness Base 0.5mm panel thickness Note: When a nameplate or an anti-rotation ring is used, add 0.03" (0.8mm) to the panel thickness dimension. Lamp Lamp Holder Inspection Window Lead Holder LED or Incandescent Panel Thickness: 0.08" (2mm) Panel Thickness: 0.1" (2.6mm) An adjustment for panel thicknesses shown below can be made quickly by using the contact block remover tool. 0.06" Contact Block (1.6mm) Tool TW-KC1 0.09" (2.3mm) 0.14" (3.5mm) 0.04" (1mm) 0.08" (2mm) 0.125" (3.2mm) Options Full Voltage Full-Size Adaptor: Transformer: Half-Size Transformer: Used with incandescent/LED – even number of contact blocks. Used with incandescent – odd number of contact blocks. Used with full voltage LED or incandescent. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3-163 A3 Switches & Pilot Devices Bezel Option: Nameplate Instructions for Switches and Pilot Devices Oiltight Switches & Pilot Devices ø22mm - TW Series Instructions con’t Pilot Lights and Pushbuttons IMPORTANT: Install the body of the TW control unit with the panel thickness scale facing up. Switches & Pilot Devices A3 Octagonal and Round Bezels Octagonal and round bezels screw into the operator. Use the locking ring wrench (optional) for secure tightening and easy removal. Round flush and extended buttons snap onto the operator base. Mushroom buttons screw onto the operator base. Every round lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Round Marking Unit Insert marking plate under lens. Press in round flush and extended lens. Screw in mushroom lens. Square Bezels Square bezels are installed in a 3-step procedure. First install the base plate from the front. Then install the lock nut using the nut locking wrench (optional). Finally, install the square bezel, which snap-fits onto the base plate. Square buttons also snap onto the operator base. Every square lens can be used with or without legend markings. Engraving can be done on a white translucent plate which is placed in the lens, or clear mylar can be printed and placed in the lens. Square units include a round waterproof lens which screws into the operator. The square outer lens snaps on. Square Marking Units Pilot Light Insert marking plate under lens. Illuminated Pushbutton Insert marking plate under lens. To remove square lens from operator, place a screwdriver under the indentation on the side of the lens. To remove the marking plate, place a screwdriver under the indentation and lift out the plate. The lens retainer can be removed by pressing a 3/16" screwdriver into one of the recesses. Marking Plate Engraving Area Shape Engraving Area Used With Part Number Ø 0.55" (14mm) Illuminated pushbuttons ALW2B Ø 0.55" (14mm) Pilot lights APW2B Mushroom Ø 0.55" (14mm) Illuminated mushroom ALW3B Square ❑ 0.83" (21mm) Square pilot lights APQW1B Square ❑ 0.83" (21mm) Square illuminated pushbuttons ALQW2B Round A3-164 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø22mm - TW Series Instructions con’t Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW-HC1) into the handle and then press handle into the operator, as shown below. Recess Press in handle . Illuminated Selector Switch Remove color insert before pulling out the handle. Non-Illuminated Selector Switch Standard Operating Positions 2-Position, 90° 3-Position, 45° 1 1 4-Position, 45° 0 2 5-Position, 30° 2 2 1 3 2 3 4 5 1 4 Positions: Non-illuminated 3-Position Operators 1 0 1 2 1 0 0 2 2 Installation TW Pilot Lights Terminal X1 = Positive Terminal X2 = Negative Make sure slot is facing up TW Illuminated Pushbuttons, TW Selector Switches (AC Transformer or Full Voltage) Lamp holder is installed as shown, due to polarity. Lead holder (used with two stacks of contact blocks) does not have polarity. Installation of LED Illuminated Units AC transformers are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. (Diode with DC power supply to protect against surges and noise.) Terminal X1 LED Terminal X2 Diode . Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A3 Switches & Pilot Devices Press in color insert A3-165 Oiltight Switches & Pilot Devices ø30mm - TWTD Series TWTD Series — Full Size NEMA Pushbuttons Switches & Pilot Devices A4 TWTD Series: Heavy duty switches built to last Key features include: • Variety of button sizes up to 2 9/16" (65mm) • Rugged construction includes chrome plated zinc locking ring die cast zinc mounting threads, screw mounted contact blocks • LED or incandescent illumination • Transformer or full voltage • Transparent contact windows • Slow make, double break self cleaning contacts • Modular construction for maximum flexibility • Double nickel plated terminal screws • Available assembled or as sub-components • NEMA 4x and IP65 watertight/oiltight panel • Large M3.5 screw terminals with captive sems plate UL Listed File No. E70646 A4-166 File No. LR48366 www.idec.com The rugged series of TWTD switches offers both variety and durability in an attractive design. With button sizes up to 2 9/16" (65mm), chrome plated zinc locking rings, die cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts, the TWTD's are here to stay. The TWTD series also offers either LED or incandescent illumination in full voltage and transformer models. Transparent contact windows allow the viewing of IDEC's self cleaning slow-make/slow-break contacts. Regardless of your switching needs, the TWTD series provides the kind of long lasting, industrial strength quality you've come to expect from IDEC. Ref. No. 117617MC Certificate No. 2005010305145658 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices Conforming to Standards Approvals Mechanical-Electrical Specifications EN60947-1, EN60947-5-1, VDE0660-200, UL508, CSA C22-2 No.14 File No. LR48366 Ref. No. 117617MC ) Operating Temperature CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) TÜV: pushbuttons and selector switches: A600=P600 (NO, NC)/Q600 (NO-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (100/110, 115, 120, 200/220, 230, 240, 380, 400/440, 480V) Operation: –25 to +50°C (without freezing) Storage: –40 to +70°C (without freezing) Vibration Resistance Shock Resistance Electric Shock Protection 10 to 55Hz, 98m/sec2 (10g) conforming to IEC6068-2-6 980m/sec2 (100g) conforming to IEC6068-2-7 Class 0 conforming to IEC60536 Degree of Protection IP65 (from front of the panel) (conforming to IEC60529) IP54 (key switches) NEMA 1, 2, 3, 3R, 3S, 4, 4X, 5, 12, 13 (conforming to NEMA ICS6-110) Mechanical Life Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 Pollution Degree (conforming to IEC60947-1) 3 for switches not using a transformer 2 for switches using a transformer Rated Operational Characteristics AC-15: A600 or Ue = 250V, le = 3A (NO, NC, NO-EM, NC-LB) DC-13: P600 or Ue = 125V, le = 1.1A (NO, NC) DC-13: Q600 or Ue = 125V, le = 0.9A (NO-EM, NC-LB) Rated Insulation Voltage Rated Switching Over-Voltage 600V Rated Impulse Withstanding Voltage 4kV for contact circuit 2.5kV for lamp circuit Rated Thermal Current Minimum Switching Capacity Contact Operation 10 Amp Less than 4kV, conforming to IEC60947-1 5 mA at 3V AC/DC Slow break NC or NO, self-cleaning Flush and extended pushbuttons—with 1NO or 1NC contact: 6.2±2N (momentary), 7.0±2N (maintained) Additional contacts—1NO or 1NC: +3.2N (momentary), + 3.3N (maintained) Operating Force Terminal Referencing Recommended Terminal Torque External Short-Circuit Protection Applicable Wire Size Contact Resistance Conforming to CENELEC EN50005 Contact Gap 4mm (NO and NC) 2mm (NO-EM and NC-LB) Incandescent: 1 W LEDs: 6, 12, 24V: 20mA / 120, 240V: 10mA Lamp Ratings 0.8 N m (7.1 in lb.) 10A 250V fuse conforming to IEC60269-1 Minimum 1 x 22 AWG, max. 2 x 14 AWG or 1 x 12 AWG Initial contact resistance of 50mΩ or less Maximum Inrush Current Contact Material 40 A (40 msec) Silver Contact Ratings by Utilization Category IEC 60947-5-1 Contact Ratings A4 Switches & Pilot Devices Specifications UL Listed File No. E70646 ø30mm - TWTD Series AC-15 (A600) DC-13 (P600) Contact Ratings by Utilization Category Operational Voltage Operation Current AC 50/60 Hz DC www.idec.com 24V 48V 50V 110V 220V 440V AC-12 Control of resistive loads & solid state loads 10A — 10A 10A 6A 2A AC-15 Control of electromagnetic loads (> 72VA) 10A — 7A 5A 3A 1A DC-12 Control of resistive loads & solid state loads 8A 5A — 2.2A 1.1A — DC-13 Control of electromagnets 5A 2A — 1.1A 0.6A — USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-167 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Non-Illuminated Pushbuttons (Assembled) Switches & Pilot Devices A4 Assembled Pushbuttons A B ( ) D 1 10 N - B Button Color B: Black G: Green R: Red S: Blue W: White Y: Yellow Function B: Momentary O: Maintained V: Pushlock Turn Reset Y: Push-Pull Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO-1NC 22: 2NO-2NC Bezel Shape Blank: Octagonal F: Full Shroud G: Mushroom Shroud P: Neoprene Boot Button Shape 1: Flush 2: Extended 3: Mushroom Ø 40mm 4: Jumbo Mushroom Ø 65mm Series Designation D: TWTD Series 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. A4-168 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Pushbuttons (Assembled) con’t Part Numbers: Non-Illuminated Pushbuttons Style Flush Contacts Part Number Momentary Maintained ABD110N-➀ ABD101N-➀ ABD111N-➀ ABD120N-➀ ABD102N-➀ AOD110N-➀ AOD101N-➀ AOD111N-➀ AOD120N-➀ AOD102N-➀ Extended 1NO 1NC 1NO-1NC 2NO 2NC ABD210N-➀ ABD201N-➀ ABD211N-➀ ABD220N-➀ ABD202N-➀ AOD210N-➀ AOD201N-➀ AOD211N-➀ AOD220N-➀ AOD202N-➀ Extended with Neoprene Boot 1NO 1NC 1NO-1NC 2NO 2NC ABPD210N-➀ ABPD201N-➀ ABPD211N-➀ ABPD220N-➀ ABPD202N-➀ AOPD210N-➀ AOPD201N-➀ AOPD211N-➀ AOPD220N-➀ AOPD202N-➀ Recessed 1NO 1NC 1NO-1NC 2NO 2NC ABFD110N-➀ ABFD101N-➀ ABFD111N-➀ ABFD120N-➀ ABFD102N-➀ AOFD110N-➀ AOFD101N-➀ AOFD111N-➀ AOFD120N-➀ AOFD102N-➀ Extended with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD210N-➀ ABFD201N-➀ ABFD211N-➀ ABFD220N-➀ ABFD202N-➀ AOFD210N-➀ AOFD201N-➀ AOFD211N-➀ AOFD220N-➀ AOFD202N-➀ 1NO 1NC 1NO-1NC 2NO 2NC ABD310N-➀ ABD301N-➀ ABD311N-➀ ABD320N-➀ ABD302N-➀ AOD310N-➀ AOD301N-➀ AOD311N-➀ AOD320N-➀ AOD302N-➀ Ø 40mm Mushroom Head with Full Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD310N-➀ ABGD301N-➀ ABGD311N-➀ ABGD320N-➀ ABGD302N-➀ AOGD310N-➀ AOGD301N-➀ AOGD311N-➀ AOGD320N-➀ AOGD302N-➀ Ø 65mm Jumbo Mushroom Head 1NO 1NC 1NO-1NC 2NO 2NC ABD410N-➀ ABD401N-➀ ABD411N-➀ ABD420N-➀ ABD402N-➀ AOD410N-➀ AOD401N-➀ AOD411N-➀ AOD420N-➀ AOD402N-➀ Ø 65mm Jumbo Mushroom Head with Shallow Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABGD410N-➀ ABGD401N-➀ ABGD411N-➀ ABGD420N-➀ ABGD402N-➀ AOGD410N-➀ AOGD401N-➀ AOGD411N-➀ AOGD420N-➀ AOGD402N-➀ Ø 65mm Jumbo Mushroom Head With Deep Shroud 1NO 1NC 1NO-1NC 2NO 2NC ABFD410N-➀ ABFD401N-➀ ABFD411N-➀ ABFD420N-➀ ABFD402N-➀ AOFD410N-➀ AOFD401N-➀ AOFD411N-➀ AOFD420N-➀ AOFD402N-➀ Ø 40mm Mushroom Head www.idec.com A4 1. In place of ➀, specify the Button Color Code. 2. For sub-assembly part numbers, see next page. 3. For accessories, see page A4-188. 4. † Neoprene boot available only in Black (B), Green (G), Red (R) and Yellow (Y). ① Button Color Code Color Code Black B Green G Red R Blue S White W Yellow Y 1. 65mm Jumbo mushroom not available in white. 2. Neoprene boot is not available in blue or white. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-169 Switches & Pilot Devices 1NO 1NC 1NO-1NC 2NO 2NC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + Operator + Button + = Complete Part Part Number Part Numbers: Buttons and Lenses Style Switches & Pilot Devices A4 Part Numbers: Operators Style Momentary Maintained Part Number Flush Flush/Extended ABD1BN-① ABD-100 AOD-100 Extended ABD2BN-① Extended with Full Shroud ABFD-200 AOFD-200 Ø 40mm Mushroom Ø 40mm Mushroom/ Ø 65mm Jumbo Mushroom ABD3BN-① ABD-300 AOD-300 Ø 65mm Jumbo Mushroom Ø 40mm Mushroom with Full Shroud ABD4BN-① ABGD-300 AOGD-300 In place of ①, specify the Button Color Code. (See table previous page) Ø 65mm Jumbo Mushroom with Shallow Shroud ABGD-400 AOGD-400 Part Numbers: Contact Blocks Description Part Number 1NO Ø 65mm Jumbo Mushroom with Deep Shroud ABFD-400 AOFD-400 Dummy Block 1NC BST-010 BST-001 BST-010S BST-001S (early make) (late break) BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts. A4-170 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series E-Stops (Assembled) A4 Lamp Voltage (full voltage illuminated units only) Function V: Pushlock Turn Reset Y: Push-Pull 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V: 120V AC/DC 240V: 240V AC/DC Illumination Blank: None L: Illuminated Series Designation D: TWTD Series Button/Lens Color A: Amber R: Red G: Green S: Blue Button/Lens Size 3: 40mm Mushroom Illuminated Circuit (illuminated unit only) 99: Full Voltage (lamp determines voltage) 126:120V AC Step Down Transformer 246: 240V AC Step Down Transformer 486: 480V AC Step Down Transformer W: White Y: Yellow Lamp Type (illuminated units only) Blank: Incandescent D: LED Contact Arrangement 10: 1NO 01: 1NC 20: 2NO 02: 2NC 11: 1NO/1NC 22: 2NO/2NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. Custom contact configurations available, contact IDEC for details. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-171 Switches & Pilot Devices Assembled E-Stops A V (L) D 3 (99) 11 (D) N - R - (24V) ø30mm - TWTD Series Oiltight Switches & Pilot Devices E-Stops (Assembled) Part Numbers: E-Stop Switches Style A4 Ø 40mm Pushlock Turn Reset Switches & Pilot Devices Non-Illuminated Ø 40mm Illuminated Pushlock Turn Reset Contacts Part Number 1NO 1NC 1NO-1NC 2NO 2NC AVD310N-R* AVD301N-R* AVD311N-R* AVD320N-R* AVD302N-R* 1NO-1NC 2NO 2NC AVLD39911➄N-R-➂* AVLD39920➄N-R-➂* AVLD39902➄N-R-➂* Transformer 1NO-1NC 2NO 2NC AVLD3 ➃ 11➄N-R* AVLD3 ➃ 20➄N-R* AVLD3 ➃ 02➄N-R* Non-Illuminated 1NO 1NC 1NO-1NC 2NO 2NC AYD310N-➀ AYD301N-➀ AYD311N-➀ AYD320N-➀ AYD302N-➀ Full Voltage 1NO-1NC 2NO 2NC AYLD39911➄N-➁-➂ ** AYLD39920➄N-➁-➂ ** AYLD39902➄N-➁-➂ ** Transformer 1NO-1NC 2NO 2NC AYLD3 ➃ 11➄N-➁ ** AYLD3 ➃ 20➄N-➁ ** AYLD3 ➃ 02➄N-➁** Full Voltage 1NO-1NC 1NC-1LB† AYLD229911➄N-➁-➂ -TK962 AYLD229902S➄N-➁-➂-TK962 Full Voltage 3 Position Push-Pull Contact Push Center Pull NC (BST-001) 0 0 X NC-LB (BST-001S) 0 X X NO (BST-010) X 0 0 NO-EM (BST-010S) X X 0 1. In place of ➀, specify the button color code 2. In place of ➁, specify the lens color code. 3. In place of ➂, specify the Full Voltage (lamp voltage) Code. 4. In place of ➃, specify the transformer voltage code. 5. In place of ➄, specify the Lamp Type code. 6. *Available in red only. 7. 3 position push-pull available in spring return to center only. 8. † The most common configuration for motor starting applications. 9. For accessories, see page A4-188. 10. For dimensions, see page A4-192. Ø 40mm Push-Pull Ø 40mm Push-Pull ① Button Color Code Ø 40mm Momentary Push-Pull (3-position) Transformer Part Numbers: Unibody E-Stops Style Ø 40mm Pushlock Turn Reset (available in Red only) 1NO-1NC 1NC-1LB† AYLD22 ➃ 11➄N-➁-TK962 AYLD22 ➃ 02S➄N-➁-TK962 Color Code Black B Amber A Green G Green G Red R Red R Blue S Blue S Yellow Y White W ➂ Full Voltage Code Contacts Part Number Voltage 6V AC/DC 6V 1NO-1NC 2NC HN1E-BV4F11-R* HN1E-BV4F02-R* 12V AC/DC 12V Code 1NO-1NC 2NC HN1E-LV4F11Q➄-R-➂ HN1E-LV4F02Q➄-R-➂ ➃ Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 24V AC/DC 24V Illuminated Ø 40mm Pushlock Turn Reset (available in Red only) 120V AC 120V 240V AC 240V (LED only) 126 246 486 Transformers step down to 6V. ➄ Lamp Type Code 1. * Available in Red only. 2. **Not available in blue. 3. In place of ➂, specify Full Voltage Code. 4. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions. 5. For nameplates and accessories, see page A3-96. 6. For dimensions, see page A3-100. 7. For sub-assembly part numbers, see next page. 8. HN1E series E-stops comply with EN418, the IEC “E-Stop Addendum to the Low Voltage Directive,” this includes “tamper proof” operation whereby a change of contact state is not possible by “teasing” or “floating” the operator. A4-172 ➁ LED Color Codes Code Color www.idec.com Lamp Code Incandescent Blank LED D USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series E-Stops (Sub-Assembled) Transformer* + Operator + Lamp + Button/Lens = Complete Part A4 Part Numbers: Lamps Type Voltage LED Ø 40mm Pushlock Turn Reset AVD-300 Illuminated Ø 40mm Pushlock Turn Reset Incandescent AVLD3-0600N Ø 40mm Push-Pull AYD-3100 2 pos AYLD-0600 Illuminated Ø 40mm Push-Pull ① Button Color Code Part Number Color Code 6V AC/DC LSTD-6➁ Black B 12V AC/DC LSTD-1➁ Green G 24V AC/DC LSTD-2➁ Red R 120V AC LSTD-H2➁ Blue S 240V AC LSTD-M4➁ Yellow Y 6V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 120VAC L-120L 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Part Numbers: Contact Blocks Description All Control Units 3 pos ➁ LED Color Codes Color Code Amber A Green G Red R Blue S White W Part Number 1NO 1NC AYLD22TK962-0B01 Part Numbers: Buttons and Lenses Style Part No. Dummy Blocks Button for Pushlock Turn Reset E-Stop (Ø 40mm, red only) AVN3B-R Lens for Illuminated Pushlock Turn Reset E-Stop (Ø 40mm, red only) AVLN3LU-R BST-010 BST-001 BST-010S BST-001S (early make) (late break) BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Part Numbers: Full Voltage Clips Primary Voltage (50/60Hz) Part Number Full Voltage Clips (2 req’d for each unit) APD-F Button for Push-Pull E-Stop (Ø 40mm) Lens for Illuminated Push-Pull E-Stop (Ø 40mm) AYD3BN-① 2 pos* AYLD3L-➁ 3 pos AYLD2L-➁ 1. In place of ①, specify the Button Color Code. (See table below) 2. In place of ➁, specify the LED Color Code. 3. *Not available in blue. www.idec.com Part Numbers: Transformers Primary Voltage Description (50/60Hz) Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 6V secondary voltage (uses 6V lamp). USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-173 Switches & Pilot Devices *Not required for full voltage units (full voltage clips used instead). Part Numbers: Operators Style Part Number Oiltight Switches & Pilot Devices ø30mm - TWTD Series Pilot Lights (Assembled) Switches & Pilot Devices A4 Assembled Pilot Lights A P D 1 126 D N - R - ( Function P: Pilot Light ) Lamp Voltage (Full Voltage Only) 6V: 6V AC/DC 12V:12V AC/DC 24V:24V AC/DC 120V:120V AC 240V: 240V AC (LED only) Series Designation D: TWTD Series Lens Shape 1: Dome Rated Operational Voltage (Primary) Transformer Type Full Voltage Type 126:120V AC 99:Full Voltage 246:240V AC 486:480V AC Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Type Blank: Incandescent Lamp D: LED Lamp Use only when interpreting part numbers. Do not use for developing part numbers. Part Numbers: LED and Incandescent Pilot Lights Style Operating Voltage Part Number Transformer Dome LED 120V AC 240V AC 480V AC APD1126DN-➁ APD1246DN-➁ APD1486DN-➁ Incandescent APD1126N-➁ APD1246N-➁ APD1486N-➁ Full Voltage Dome — APD199DN-➁-➂ 1. In place of ➁, specify the Lens/LED Color Code. 2. In place of ➂, specify the Full Voltage Code (lamp voltage). A4-174 www.idec.com APD199N-➁-➂ ➁ Lens Color Code Color Code Amber A Green G Red R Blue S White W Yellow Y ➂ Full Voltage Code Voltage Code 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC (LED only) 6V 12V 24V 120V 240V USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Pilot Lights (Sub-Assembled) Transformer* + Operator + Lamp + Lens = Complete Part A4 Part Numbers: Operators Style Part Number Part Numbers: Full Voltage Clips Primary Voltage (50/60Hz) Part Number Full Voltage APD-F APD-199 Required for all full voltage models. Two pieces each. AC Adaptor/Transformer APD-006 Part Numbers: Transformers Primary Voltage Description (50/60Hz) Transformers The lens, lamp, and transformer/adaptor or the full voltage clips must be ordered separately. Part Numbers: Lenses Style Part Number Dome Lens Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 6V secondary voltage (use 6V lamp). APN106L-➁ 1. In place of ➁, specify the Lens Color Code. 2. LED and incandescent lenses differ in shade only. Some colors have only one shade. Code Amber A Green G Red R Blue S LSTD-6➁ White W 12V AC/DC LSTD-1➁ Yellow Y 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 12V AC/DC IS-12 6V AC/DC Incandescent Color Part Number Part Numbers: Lamps Type Voltage LED ➁ Lens/LED Color Code 24V AC/DC IS-24 120VAC, 1-8W L-120L 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-175 Switches & Pilot Devices Note: Not required for full voltage units (full voltage clips used instead). Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Pushbuttons (Assembled) Switches & Pilot Devices A4 Assembled Illuminated Pushbuttons A L ( ) D 2 126 11 (D) N - R - ( ) Function L: Momentary Action OL: Alternate Action Lamp Voltage (Full Voltage Only) 6V: 6V AC/DC 12V: 12V AC/DC 24V: 24V AC/DC 120V:120V AC 240V: 240V AC (LED only) Bezel Shape Blank: Octagonal F: Full Shroud Series Designation D: TWTD Series Lens Shape 2: Extended 3: Mushroom Ø 40mm Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Rated Operational Voltage (Primary) Transformer Full Voltage Type 126:120V AC 99:Full Voltage 246:240V AC 486:480V AC Lamp Type Blank: Incandescent Lamp D: LED Contact Arrangement 20: 2NO 02: 2NC 11: 1NO-1NC 1. Use only when interpreting part numbers. Do not use for developing part numbers. 2. All transformers and AC Adaptors step down to 6V. A4-176 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Pushbuttons (Assembled) con’t Part numbers: Illuminated Pushbuttons Style Extended Lens with Full Shroud Ø 40mm Mushroom Lens Momentary A4 Maintained Full Voltage 1NO-1NC 2NO 2NC ALD29911➄N-➁-➂ ALD29920➄N-➁-➂ ALD29902➄N-➁-➂ AOLD29911➄N-➁-➂ AOLD29920➄N-➁-➂ AOLD29902➄N-➁-➂ Transformer 1NO-1NC 2NO 2NC ALD2 ➃ 11➄N-➁ ALD2 ➃ 20➄N-➁ ALD2 ➃ 02➄N-➁ AOLD2 ➃ 11➄N-➁ AOLD2 ➃ 20➄N-➁ AOLD2 ➃ 02➄N-➁ Full Voltage 1NO-1NC 2NO 2NC ALFD29911➄N-➁-➂ ALFD29920➄N-➁-➂ ALFD29902➄N-➁-➂ AOLFD29911➄N-➁-➂ AOLFD29920➄N-➁ ➂ AOLFD29902➄N-➁-➂ Transformer 1NO-1NC 2NO 2NC ALFD2 ➃ 11➄N-➁ ALFD2 ➃ 20➄N-➁ ALFD2 ➃ 02➄N-➁ AOLFD2 ➃ 11➄N-➁ AOLFD2 ➃ 20➄N-➁ AOLFD2 ➃ 02➄N-➁ Full Voltage 1NO-1NC 2NO 2NC ALD39911➄N-➁-➂ ALD39920➄N-➁-➂ ALD39902➄N-➁-➂ AOLD39911➄N-➁-➂ AOLD39920➄N-➁-➂ AOLD39902➄N-➁-➂ Transformer 1NO-1NC 2NO 2NC ALD3 ➃ 11➄N-➁ ALD3 ➃ 20➄N-➁ ALD3 ➃ 02➄N-➁ AOLD3 ➃ 11➄N-➁ AOLD3 ➃ 20➄N-➁ AOLD3 ➃ 02➄N-➁ Switches & Pilot Devices Extended Lens Part Number Contacts 1. In place of ➁, specify the Lens Color Code. 2. In place of ➂, specify the Full Voltage Code (lamp voltage). 3. In place of ➃, specify the Transformer Voltage Code. 4. In place of ➄, specify the Lamp Type Code. ➁ Lens Color Codes Color Code ➂ Full Voltage Codes Voltage Code Amber A 6V AC/DC 6V Green G 12V AC/DC 12V Red R 24V AC/DC 24V Blue S 120V AC 120V White W 240V AC (LED only) 240 V Yellow Y ➃ Transformer Voltage Codes Voltage Code 120VAC 240VAC 480VAC 126 246 486 6V secondary voltage (uses 6V lamp). ➄ Lamp Type Code Lamp Code Incandescent Blank LED D www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-177 Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Pushbuttons (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp + Lens = Complete Part Switches & Pilot Devices A4 * Not required for full voltage types (full voltage types use APD-F full voltage clips). Part Numbers: Operators Part Number Style Part Numbers: Lamps Type Voltage Momentary Maintained LED Extended ALD-0600 AOLD-0600 Incandescent Extended with Full Shroud ALFD-0600 AOLFD-0600 40mm Mushroom ALD-0600 AOLD-0600 ➁ Lens/LED Color Codes Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ Green G 24V AC/DC LSTD-2➁ Red R 120V AC LSTD-H2➁ Blue S 240V AC LSTD-M4➁ White W 6V AC/DC IS-6 Yellow Y 12V AC/DC IS-12 24V AC/DC IS-24 120VAC L-120L Mushroom lens not available in yellow. 1. In place of ➁, specify the LED Color code. 2. The LED contains a current-limiting resistor and a protection diode. All Control Units ALN06LU-➁ Dummy Blocks ALN3LU-➁ 1. In place of ➁, specify the Lens Color Code. 2. LED and incandescent lenses differ in shade only. Some colors have only one shade. Part Numbers: Full Voltage Clips Primary Voltage (50/60Hz) Part Number Full Voltage Clips (2 req’d for each unit) APD-F Required for all full voltage models. Part Number 1NO Extended Ø 40mm Mushroom Code A Amber Part Numbers: Contact Blocks Description Part Numbers: Lenses Style Part No. Color 1NC BST-010 BST-001 BST-010S BST-001S (early make) (late break) BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Part Numbers: Transformers Primary Voltage Description (50/60Hz) Transformers Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 6V secondary voltage (uses 6V lamp). A4-178 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Selector Switches (Assembled) A4 Key Selector (Non-illuminated) Switches & Pilot Devices Knob Selector (Non-illuminated) Lever Selector (Non-illuminated) Assembled Selector Switches A S D 2 ( ) ( ) 11 N - ( ) Function S: Selector Switch Circuit Number Series Designation D: TWTD Series Contact Arrangement Code 10: 1NO 01: 1NC 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC (See Circuit # column of Selector Switch Contact Arrangement Chart on beginning on A4-185.) Number of Positions 2: 2-Position 3: 3-Position Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: 2-Way spring return from Left and Right Operator Style Code Blank: Knob Operator L: Lever Operator K: Key Operator Use only when interpreting part numbers. Do not use for developing part numbers. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-179 Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Selector Switches (Assembled) con’t Mounting 1NO 1 2 O O X O 1NC 1 2 X O O O 1NO 1NC 1 2 O X X O 2NO 1 2 O O X X 2NC 1 2 X X O O 1 2 3 4 1 2 3 4 O X O X O O X X X O X O X X O O 2NO 2NC 2NO 2NC L R L R L Part Number Spring Return from Left L R R Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key Knob Lever Key ASD210N ASD2L10N ASD2K10N ASD201N-116 ASD2L01N-116 ASD2K01N-116 ASD211N ASD2L11N ASD2K11N ASD220N ASD2L20N ASD2K20N ASD202N-104 ASD2L02N-104 ASD2K02N-104 ASD2110N ASD21L10N ASD21K10N ASD2101N-116 ASD21L01N-116 ASD21K01N-116 ASD2111N ASD21L11N ASD21K11N ASD2120N ASD21L20N ASD21K20N ASD2102N-104 ASD21L02N-104 ASD21K02N-104 ASD2210N ASD22L10N ASD22K10N ASD2201N-116 ASD22L01N-116 ASD22K01N-116 ASD2211N ASD22L11N ASD22K11N ASD2220N ASD22L20N ASD22K20N ASD2202N-104 ASD22L02N-104 ASD22K02N-104 Knob Lever Key ASD222N ASD2L22N ASD2K22N ASD2122N ASD21L22N ASD21K22N ASD2222N ASD22L22N ASD22K22N Knob Lever Key ASD222N-111 ASD2L22N-111 ASD2K22N-111 ASD2122N-111 ASD21L22N-111 ASD21K22N-111 ASD2222N-111 ASD22L22N-111 ASD22K22N-111 Mounting Part Numbers: Non-Illuminated 3–Position Selector Switches Style Part Number Part Number Part Number Part Number Operator Position Maintained Spring Return from Right Spring Return From Left Spring Return Two-Way Contact Switches & Pilot Devices A4 Contact Part numbers: Non-Illuminated 2–Position Selector Switches Style Part Number Part Number Operator Position Spring Return from Right Maintained 2NO 1 2 X O O O O X 2NC 1 2 O X X X X O 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 X O O X X X O O O O O O X O X O O X O X O O X X O X X O X O X O O O O O X X X X O X X O X O O X O X O X O X O X X O X O 2NO 2NC 2NO 2NC 2NO 2NC 4NO 4NC C L C R L L C C C R R L R L Knob Lever Key Knob Lever Key ASD320N ASD3L20N ASD3K20N ASD302N ASD3L02N ASD3K02N ASD3120N ASD31L20N ASD31K20N ASD3102N ASD31L02N ASD31K02N ASD3220N ASD32L20N ASD32K20N ASD3202N ASD32L02N ASD32K02N ASD3320N ASD33L20N ASD33K20N ASD3302N ASD33L02N ASD33K02N Knob Lever Key ASD322N ASD3L22N ASD3K22N ASD3122N ASD31L22N ASD31K22N ASD3222N ASD32L22N ASD32K22N ASD3322N ASD33L22N ASD33K22N Knob Lever Key ASD322N-309 ASD3L22N-309 ASD3K22N-309 ASD3122N-309 ASD31L22N-309 ASD31K22N-309 ASD3222N-309 ASD32L22N-309 ASD32K22N-309 ASD3322N-309 ASD33L22N-309 ASD33K22N-309 Knob Lever Key ASD322N-310 ASD3L22N-310 ASD3K22N-310 ASD3122N-310 ASD31L22N-310 ASD31K22N-310 ASD3222N-310 ASD32L22N-310 ASD32K22N-310 ASD3322N-310 ASD33L22N-310 ASD33K22N-310 Knob Lever Key ASD340N ASD3L40N ASD3K40N ASD3140N ASD31L40N ASD31K40N ASD3240N ASD32L40N ASD32K40N ASD3340N ASD33L40N ASD33K40N Knob Lever Key ASD304N ASD3L04N ASD3K04N ASD3104N ASD31L04N ASD31K04N ASD3204N ASD32L04N ASD32K04N ASD3304N ASD33L04N ASD33K04N R 1. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (closed contacts) O = Off (open contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions. 2. All knob and lever selector switches come in black. Other colors are available by ordering the knob or lever separately. 3. Custom contact arrangements available, see page A4-185 or call IDEC for details. A4-180 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + Operator + Knob or Lever* + Color Insert* = Complete Part † A4 Switches & Pilot Devices 1. * Not needed with key type switches. 2. † Knob type shown. Part Numbers: Operators Appearance/ Description Position 2 Knob & Lever 2 3 3 2 Key 2 3 3 Part Number Maintained ASD200 Spring-Ret. from Right ASD2100 Spring-Ret. from Left ASD2200 Maintained, Cam 1 Maintained, Cam 2 ASD300-1 ASD300-2 Spring-Ret. from Right, Cam1 Spring-Ret. from Right, Cam 2 ASD3100-1 ASD3100-2 Spring-Ret. from Left, Cam 1 Spring-Ret. from Left, Cam 2 ASD3200-1 ASD3200-2 Spring-Ret. from L/R, Cam 1 Spring-Ret. from L/R, Cam 2 ASD3300-1 ASD3300-2 Maintained ASD2K00-RA Spring-Ret. from Right ASD21K00-RL Spring-Ret. from Left ASD22K00 Maintained, Cam 1 Maintained, Cam 2 ASD3K00-1-RA ASD3K00-2-RA Spring-Ret. from Right, Cam1 Spring-Ret. from Right, Cam 2 ASD31K00-1-RLC ASD31K00-2-RLC Spring-Ret. from Left, Cam 1 Spring-Ret. from Left, Cam 2 ASD32K00-1-RRC ASD32K00-2-RRC Spring-Ret. from L/R, Cam 1 Spring-Ret. from L/R, Cam 2 ASD33K00-1-RC ASD33K00-2-RC Part Numbers: Handles and Inserts Style Part Number Knob ASDHHY - ① Lever ASDHHL -① Color Insert TW-HC1 - ① In place of ①, specify the Color Code. Part Numbers: Contact Blocks Style 1. Order knobs, levers, color inserts separately (see below). 2. For key switches, keys are removable in all maintained positions. Other options available, contact IDEC for details. 3. See page A4-187 “Operator Truth Tables” for details of difference between cams. Part Number 1NO 1NC BST-010 BST-010S (early BST-001 BST-001S (late make) break) ① Color Codes Knob/Lever Color Code Black Blue Green Red Yellow White B S G R Y W Dummy Blocks BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). 1. Knob/Lever not available in white. 2. Color inserts not available in Black. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-181 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Illuminated Selector Switches (Assembled) Switches & Pilot Devices A4 Assembled Illuminated Selector Switches A SL D 2 (2) 126 11 D N - 111 - R - 24 Lamp Voltage (Full Voltage Only) 6V: 6V AC/DC 12V:12V AC/DC 24V:24V AC/DC 120V:120V AC 240V: 240V AC (LED only) Function SL: Illuminated Selector Switch Series Designation D: TWTD Series Number of Positions 2: 2-Position 3: 3-Position Spring Return Action Blank: Maintained 1: Spring return from Right 2: Spring return from Left 3: 2-Way spring return from Left and Right Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Rated Operational Voltage (Primary) Transformer Full Voltage Type 126:120V AC 99: Full Voltage 246:240V AC 486:480V AC Circuit Code Number See Circuit # column of Selector Switch Contact Arrangement Charts on page A4-185. Contact Arrangement 20: 2NO 02: 2NC 40: 4NO 04: 4NC 11: 1NO-1NC 22: 2NO-2NC Lamp Type Blank: Incandescent D: LED Use only when interpreting part numbers. Do not use for developing part numbers. A4-182 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Selector Switches (Assembled) con’t Mounting L R L ➁ Lens/LED Color Codes Spring Return From Left L L R 1NO 1 1NC 2 O X X O transformer full voltage ASLD2 ➃11➄N-➁ ASLD29911➄N-➁-➂ ASLD21 ➃11➄N-➁ ASLD219911➄N-➁-➂ ASLD22 ➃11➄N-➁ ASLD229911➄N-➁-➂ 2NO 12 O O X X O X O X O O X X X X O O X O X O X X O O transformer full voltage transformer full voltage ASLD2 ➃20➄N-➁ ASLD29920➄N-➁-➂ ASLD2 ➃02➄N-104-➁ ASLD29902➄N-104-➁-➂ ASLD21 ➃20➄N-➁ ASLD219920➄N-➁-➂ ASLD21 ➃02➄N-104-➁ ASLD219902➄N-104-➁-➂ ASLD22 ➃20➄N-➁ ASLD229920➄N-➁-➂ ASLD22 ➃02➄N-104-➁ ASLD229902➄N-104-➁-➂ transformer full voltage ASLD2 ➃22➄N-➁ ASLD29922➄N-➁- ➂ ASLD21 ➃22➄N-➁ ASLD219922➄N-➁-➂ ASLD22 ➃22➄N-➁ ASLD229922➄N-➁-➂ 2NC 12 1 2NO 2 2NC 3 4 1 2NO 2 2NC 3 4 transformer full voltage ASLD2 ➃22➄N-11-➁ ASLD29922➄N-111-➁-➂ R ASLD21 ➃22➄N-111-➁ ASLD219922➄N-111-➁-➂ R ASLD22 ➃22➄N-111-➁ ASLD229922➄N-111-➁-➂ 2NC 2NO 2NC 2NO 2NC 2NO 2NC 4NO 4NC Mounting Contact 2NO 1 2 1 2 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 C L C R X O O X X O O X X X O O O O O O X O X O O X O X O O X X O O X X O X X O X O X O O O O O X X X X O X X O O X X O X O O X O X O X O X O X X O X O L Code Incandescent Blank LED D C R L Voltage A4 Code 6V AC/DC 12V AC/DC 24V AC/DC 120V AC 240V AC (LED only) 6V 12V 24V 120V 240V ➃Transformer Voltage Codes Voltage Code 126 246 486 6V secondary voltage (uses 6V lamps). Spring Return From Left Spring Return Two-Way C C L R A G R S W Y 120VAC 240VAC 480VAC Lamp Spring Return From Right Code Amber Green Red Blue White Yellow ➂ Full Voltage Codes ➄ Lamp Type Code Part Numbers: Illuminated 3–Position Selector Switches Style Operator Maintained Position Color R L R transformer full voltage transformer full voltage ASLD3 ➃ 20➄N-➁ ASLD39920➄N-➁-➂ ASLD3 ➃ 02➄N-➁ ASLD39902➄N-➁-➂ ASLD31 ➃ 20➄N-➁ ASLD319920➄N-➁- ➂ ASLD31 ➃ 02➄N-➁ ASLD319902➄N-➁-➂ ASLD32 ➃ 20D➄N-➁ ASLD329920D➄N-➁-➂ ASLD32 ➃ 02D➄N-➁ ASLD329902D➄N-➁-➂ ASLD33 ➃ 20D➄N-➁ ASLD339920D➄N-➁-➂ ASLD33 ➃ 02D➄N-➁ ASLD339902D➄N-➁-➂ transformer full voltage ASLD3 ➃ 22➄N-➁ ASLD39922➄N-➁-➂ ASLD31 ➃ 22➄N-➁ ASLD319922➄N-➁-➂ ASLD32 ➃ 22D➄N-➁ ASLD329922D➄N-➁-➂ ASLD33 ➃ 22D➄N-➁ ASLD339922D➄N-➁-➂ transformer full voltage ASLD3 ➃ 22➄N-309-➁ ASLD39922➄N-309-➁-➂ ASLD31 ➃ 22➄N-309-➁ ASLD319922➄N-309-➁-➂ ASLD32 ➃ 22D➄N-309-➁ ASLD329922D➄N-309-➁-➂ ASLD33 ➃ 22D➄N-309-➁ ASLD339922D➄N-309-➁-➂ transformer full voltage ASLD3 ➃ 22➄N-310-➁ ASLD39922➄N-310-➁-➂ ASLD31 ➃ 22➄N-310-➁ ASLD319922➄N-310-➁-➂ ASLD32 ➃ 22D➄N-310-➁ ASLD329922D➄N-310-➁-➂ ASLD33 ➃ 22D➄N-310-➁ ASLD339922D➄N-310-➁-➂ transformer full voltage ASLD3 ➃ 40➄N-➁ ASLD39940➄N-➁-➂ ASLD31 ➃ 40➄N-➁ ASLD319940➄N-➁-➂ ASLD32 ➃ 40➄N-➁ ASLD329940➄N-➁-➂ ASLD33 ➃ 40➄N-➁ ASLD339940➄N-➁-➂ transformer full voltage ASLD3 ➃ 04➄N-➁ ASLD39904➄N-➁-➂ ASLD31 ➃ 04➄N-➁ ASLD319904➄N-➁-➂ ASLD32 ➃ 04➄N-➁ ASLD329904➄N-➁-➂ ASLD33 ➃ 04➄N-➁ ASLD339904➄N-➁-➂ 1. In place of ➁, specify the Lens/LED Color Code, in place of ➂, specify the Full Voltage (lamp voltage) Code, in place of ➃, specify the Transformer Voltage Code and in place of ➄ specify the Lamp Type Code. 2. The truth table indicates the operating position of contact block when the operator is switched to that position. X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed contacts) when switch is moved between these positions www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-183 Switches & Pilot Devices Contact Part Numbers: Illuminated 2–Position Selector Switches Style Operator Spring Return Maintained Position From Right Oiltight Switches & Pilot Devices ø30mm - TWTD Series Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + Operator + Lamp Lense = Complete Part Switches & Pilot Devices A4 *Not required for full voltage units (use APD-F full voltage clips instead). Part Numbers: Operators Appearance/ Description Positions 2 Operator 3 2 3 Part Number Maintained Maintained, Cam 1 Maintained, Cam 2 Spring-Ret. from Right Spring-Ret. from Left Spring-Ret. from Right, Cam 1 Spring-Ret. from Right, Cam 2 Spring-Ret. from Left, Cam 1 Spring-Ret. from Left, Cam 2 Spring-Ret. from L/R, Cam 1 Spring-Ret. from L/R, Cam 2 Knob ASLNHU - ➀ LED Incandescent Part Number 1NO Dummy Blocks 1NC BST-010 BST-001 BST-010S BST-001S (early make) (late break) BST-D 1. Dummy blocks (no contacts) are used with an odd number of contact blocks. 2. Combining BST-010S and BST-001S result in overlapping contacts (make before break). Part Numbers: Lenses Style Part Number Part Numbers: Lamps Type Voltage ASLD200 ASLD300-1 ASLD300-2 ASLD2100 ASLD2200 ASLD3100-1 ASLD3100-2 ASLD3200-1 ASLD3200-2 ASLD3300-1 ASLD3300-2 Contact Blocks Description Part Numbers: Full Voltage Clips Primary Voltage (50/60Hz) Full Voltage Clips Part Number APD-F (2 req’d for each unit) Part Number 6V AC/DC LSTD-6➁ 12V AC/DC LSTD-1➁ 24V AC/DC LSTD-2➁ 120V AC LSTD-H2➁ 240V AC LSTD-M4➁ 6.3V AC/DC IS-6 12V AC/DC IS-12 24V AC/DC IS-24 120VAC L-120L 1. In place of ➁, specify the LED color code. 2. The LED contains a current-limiting resistor and a protection diode. Part Numbers: Transformers Primary Voltage Description (50/60Hz) Transformers Part Number 120V AC TWD-0126 240V AC TWD-0246 480V AC TWD-0486 6V secondary voltage ➁ Lens/LED Color Codes A4-184 www.idec.com Color Code Amber Green Red Blue White Yellow A G R S W Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement Type and quantity of switch contacts L R 4 2 Operator Position * N/D = No designation Contact Block Mounting Position or mounting contact blocks on operator Truth table indicates the operating position of contact block when operator is switched to that position. 3 1 X = On (Closed Contacts) O = Off (Open Contacts) X X = Overlapping Contacts: Remain on (closed) when switch is moved between these two positions Contact Block Part Number Part number to use when ordering subassembly contact blocks, as required for use with corresponding mounting position Contact Arrangement Chart: 2-position Selector Switches Style Mounting Operator Contact Block Description Circuit Position Position Part Number Contact Number L R Operator Part Number Spring Ret. Spring Ret. Maintained from Rt. from Lt. L 1NO N/D 1NC 116 N/D 1NO 1NC 103 600 1NO-EM 1NC-LB 601 2NO N/D 2NC 104 N/D 2NO 2NC 110 111 4NO N/D www.idec.com 1 O X BST-010 2 O O BST-D 1 X O BST-001 2 O O BST-D 1 O X BST-010 2 X O BST-001 1 X O BST-001 2 O X BST-010 1 O X BST-010S 2 X O BST-001S 1 X O BST-001S 2 O X BST-010S 1 O X BST-010 2 O X BST-010 1 X O BST-001 2 X O BST-001 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 O X O X X O X O O O X X O O O O X O X O O X O X X X O O X X X X BST-010 BST-001 BST-010 BST-001 BST-001 BST-010 BST-001 BST-010 BST-010 BST-010 BST-001 BST-001 BST-010 BST-010 BST-010 BST-010 R L R L R Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 Knob/Lever Key Illuminated Knob ASD200 ASD2K00 ASLD200 ASD2100 ASD21K00 ASLD2100 ASD2200 ASD22K00 ASLD2200 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-185 Switches & Pilot Devices Circuit Number A4 Oiltight Switches & Pilot Devices ø30mm - TWTD Series Contact Arrangement Chart: 3-Position Selector Switches Style Mounting Operator Contact Block Circuit Position Position Part Number Contact Number L C Description Maintained R C L Switches & Pilot Devices A4 202 203 1NO 1NC 302 303 N/D 2NO 301 304 2NC N/D N/D 210 2NO 2NC 308 309 310 N/D 4NO 305 N/D 4NC 314 Operator Part Number Spring Ret. Spring Ret. from Rt. from Lt. 1 X 0 0 BST-010 2 X X O BST-001 1 0 X X BST-001 2 O 0 X BST-010 1 X 0 X BST-010 2 X X O BST-001 1 0 X O BST-001 2 O 0 X BST-010 1 X 0 0 BST-010 2 O 0 X BST-010 1 X 0 X BST-010 2 O 0 X BST-010 1 0 X O BST-001 2 X X O BST-001 1 0 X X BST-001 2 X X O BST-001 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 X 0 0 X 0 0 0 0 X X X X X X 0 O 0 O 0 0 X 0 X 0 X 0 X 0 0 X 0 X 0 X 0 X 0 0 X X X 0 X 0 0 X 0 X 0 X X 0 X 0 X 0 0 0 0 0 0 0 0 0 X X X X X X X X 0 X X 0 X X X X X 0 X O X 0 O X O X O X 0 X 0 X X X X X X 0 X O O 0 O 0 BST-010 BST-010 BST-001 BST-001 BST-001 BST-010 BST-001 BST-010 BST-010 BST-001 BST-010 BST-001 BST-010 BST-001 BST-001 BST-010 BST-001 BST-010 BST-001 BST-010 BST-010 BST-010 BST-010 BST-010 BST-010 BST-010 BST-010 BST-010 BST-001 BST-001 BST-001 BST-001 BST-001 BST-001 BST-001 BST-001 C C R L Two-Way R L C R L R Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 Knob/Lever Key Illuminated Knob ASD300-1 ASD3K00-1 ASLD300-1 ASD3100-1 ASD31K00-1 ASLD3100-1 ASD3200-1 ASD32K00-1 ASLD3200-1 ASD3300-1 ASD33K00-1 ASLD3300-1 Knob/Lever Key Illuminated Knob ASD300-2 ASD3K00-2 ASLD300-2 ASD3100-2 ASD31K00-2 ASLD3100-2 ASD3200-2 ASD32K00-2 ASLD3200-2 ASD3300-2 ASD33K00-2 ASLD3300-2 1. Each operator sub-assembly is available as a “-1" and a “-2" for 3-position selector switches. The internal cam of a “-1" is different from that of a “-2". This results in designated combinations of open and closed contacts in the various operator positions. 2. N/D = No circuit number designation required in assembled part number. 3. X = On (closed contacts) O = Off (open contacts). X X Overlapping contacts remain on (closed) when switch is moved between these two positions. A4-186 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Operator Truth Tables Use the following tables to build custom selector switches. 2 Position Selector Switches Contact Operator Position Mounting Position BST-001 (NC) ASD200 BST-010S (NO-EM) BST-001S (NC-LB) A4 Right L O X R O X L X O R X O L 0 X R O X L X O R X O Switches & Pilot Devices BST-010 (NO) Left 3 Position Selector Switches Contact Left L X O O R O O X L O X X R X X O L X O O R O O X L O X X R X X O BST-010 (NO) ASD300-1 ASLD300-1 ASD3K00-1 BST-001 (NC) BST-010S (NO-EM) BST-001S (NC-LB) Contact Center Right Operator Position Mounting Position Left L X O R O O X L O X O R X X O L X O X R O O X L O X O R X X O BST-010 (NO) ASD300-2 ASLD300-2 ASD3K00-2 Operator Position Mounting Position BST-001 (NC) BST-010S (NO-EM) BST-001S (NC-LB) Center Right X 1. For Operator Truth Tables, see next page. 2. For examples of how to assemble selector switches, see A3-82. 3 Position Push/Pull Switches Contact BST-010 (NO) AYLD22 Operator Position Pull Normal Push O O X BST-001 (NC) X O O BST-010S (NO-EM) O X X BST-001S (NC-LB) X X O www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-187 ø30mm - TWTD Series Oiltight Switches & Pilot Devices Accessories — TWTD Series Lamp Removal Tool Tool used to install LED’s and incandescent lamps. Switches & Pilot Devices A4 Metal Bezel Replacement locking ring/bezel Plastic Bezel Standard octagonal units (chrome-pl.). OG-81 Extended, non-illuminated (chrome-pl.). OG-82 Extended, illuminated (chrome-pl.). OG-83L Jumbo Mushroom Shallow Shroud ABN4G Jumbo Mushroom Deep Shroud ABN4F Black plastic locking ring/bezel Used to cover and protect pushbuttons. Boot/Cover OR-55 OGP11B In place of ➀, specify neoprene Rubber Boot color: B (black), G (green), R (red), Y (yellow) OC-11 ➀ Flush units (clear plastic -40˚ to +60˚C). OC-121 Extended units (clear plastic -40˚ to +60˚C). OC-122 Plastic washer For nameplates or panels that should not be scratched. OGL-D1T Thrust washer/Anti-rotation ring for use with notched panel cutout. OGL-D1S Anti-Rotation Ring Mounting Hole Plug Plugs used to fill unused 30mm panel cutouts. Plastic with locking nut attached. OBP-11 Metal with locking nut attached OB-11 Grey rubber (-5˚ to +60˚C) OB-13 Terminal Tab Adaptor Tab #250 17/64" x 3/64" (6.35mm x 0.8mm): Single tab TW-FA1 Full Voltage Adaptor Used on all full voltage illuminated units. Two required per unit. (M3.5 screw and saddle) APD-F Lock Out Adaptor Used to provide lockout protection for TWTD pushbuttons and knob selectors. Ø 1-13/64" (30mm) OL-KL1 Replacement Keys Pair of Keys (#0) TW-SK A4-188 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Accessories con’t Part Numbers: Fingersafe Covers for TWTD Series Appearance Description Used with Part Number A4 N-VL2 N-VL3 N-VL4 Fingersafe terminal cover, for full voltage pilot lights, adds 3mm to overall depth APD199... full voltage pilot lights APD-PVL Fingersafe terminal cover, for contact blocks, adds 3mm to overall depth Non-Illuminated pushbuttons ABD..., and AOD... N-VL2 Fingersafe terminal cover, adds 1.5mm to overall depth Transformer pilot lights and illuminated units N-VL3 Fingersafe terminal cover, adds 4 mm to depth Full voltage illuminated pushbuttons N-VL4 Dimensions on page A4-192. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-189 Switches & Pilot Devices APD-PVL Oiltight Switches & Pilot Devices ø30mm - TWTD Series Nameplates — TWTD Series Part Numbers: Nameplates NAKD Ø1.19" (30.5mm) Emergency 1.95" (50mm) 2.24" (57.5mm) 1.85" (47.5mm) Switches & Pilot Devices Dimensions Ø1.19" (30.5mm) HNAV 1.95" (50mm) 2.03" (52mm) 1.56" (40mm) A4 NAQD 2.34" (60mm) NALD Ø1.19" (30.5mm) Ø1.19" (30.5mm) Stop 5mm Description Nameplate (blank) Part Number Part Number Part Number Black NALD-B NAKD-B NAQD-B Red NALD-R NAKD-R NAQD-R NALD-➀ NAKD-➀ NAQD-➀ Nameplate (engraved) Part Number HNAV-0 HNAV-27 “Emergency Stop” 1. Nameplates are made of 0.031" aluminum. Lettering is white letters engraved on black background. 2. In place of ➀, insert either the standard legend code from table below or custom engraving delimited by “ “. 3. HNAV available in yellow only. * Standard Legend Codes Pushbuttons Legend Code Legend AUTO CLOSE DOWN *EMERG.STOP FAST FORWARD HAND HIGH IN INCH JOG LOW LOWER OFF ON 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 OPEN OUT RAISE RESET REVERSE RUN SLOW START *STOP STOP TEST UP I (Int’l On) O (Int’l Off) EMO Pushbuttons/Selector Switches Code Legend Code Legend 116 117 118 119 120 121 122 123 124 125 126 127 150 151 152 AUTO-MAN CLOSE-OPEN DOWN-UP FAST-SLOW FOR-REV HAND-AUTO HIGH-LOW JOG-RUN LEFT-RIGHT LOWER-RAISE MAN-AUTO OFF-ON ON-OFF OPEN-CLOSE RAISE-LOWER 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 REV-FOR RUN-JOG RUN-SAFE SAFE-RUN SLOW-FAST START-STOP STOP-START UP-DOWN Code 216 217 218 219 220 221 222 223 Selector Switches Legend Code AUTO-MAN-OFF AUTO-OFF-MAN CLOSE-OFF-OPEN DOWN-OFF-SLOW FAST-OFF-SLOW FOR-OFF-REV LEFT-OFF-RIGHT LOWER-OFF-RAISE OFF-MAN-AUTO OFF-SLOW-FAST OFF-1-2 OPEN-OFF-CLOSE SLOW-OFF-FAST SUMMER-OFF-WINTER UP-OFF-DOWN 1-OFF-2 HAND-OFF-AUTO 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 1. *Available in Red as standard legend code 104 and 124. To order engraved nameplate and codes, add legend code to nameplate part number. Character height based on the number of characters, space and size of nameplate. Standard character size is 3/16". 2. Nameplates with standard legends are the same list price as blank nameplates. Special engravings, additional cost. To specify engraving instructions, use the Nameplate order form on next page. A4-190 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Nameplates Order Form — TWTD Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: IDEC Rep/Distributor Contact: Name: PO number (if known): Telephone: IDEC Rep/Distributor Phone: Fax & Email IDEC Rep/Distributor Fax & Email A4 Sample Letter Sizes 7/64” Letters: Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 13 characters. Engraving Location Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. ABCD 7/64” Letter Size 16 characters max (for 7/64” size letters) 1/8” Letter Size 13 characters max (for 1/8” size letters) 1/8” Letters: ABCD Qty 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 NAKD Nameplate Step 1. 1/8” Letter Size Only Specify Lettering Write your lettering in box to the right. Maximum 17 characters per line, maximum 4 lines. Engraving Location Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Sample Letter Size 1/8” Letters: A B C D Qty NAQD Nameplate Step 1. Choose Letter Size - 7/64” or 1/8”. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: 1/8” size letters cannot exceed 16 characters. Engraving Location 1 Step 2. Specify Quantity. Enter the number of nameplates desired in the box on the right. www.idec.com 2 3 4 5 7/64” Letter Size 20 characters max (for 7/64” size letters) 1/8” Letter Size 16 characters max (for 1/8” size letters) 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Sample Letter Sizes 7/64” Letters: A B C D Qty 1/8” Letters: A B C D USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-191 Switches & Pilot Devices NALD Nameplate Oiltight Switches & Pilot Devices ø30mm - TWTD Series Dimensions — TWTD Series Pushbutton ø40 ø35 ø25 5.5 23 40 53 (1 or 2 blocks) 9 14.5 76 (3 or 4 blocks) Mushroom Pushbutton w/Full Shroud Panel Thickness 0.8 to 7.5 ø40 M3.5 Terminal Screw B 5.5 23 Dimension A Dimension B Flush Extended Extended w/Full Shroud 0.351" (9mm) 0.566" (14.5mm) 0.663" (17mm) Ø 0.975" (25mm) Ø 0.975"(25mm) Ø 1.11" (28.5mm) Mushroom Mushroom w/Full Shroud Jumbo Mushroom Ø 1.56" (40mm) 0.858" (22mm) 0.936" (24mm) 1.13" (29mm) Ø 1.56" (40mm) Ø 1.87" (48mm) Ø 2.54" (65mm) Mushroom, Pushlock Turn Reset and Push-Pull Ø 1.56" (40mm) *0.975" (25mm) **0.975" (25mm) Ø 1.56" (40mm) Ø 1.56" (40mm) Note: *Dimension when operator is in reset position. **Dimension when operator is in pull position. 40 53 (1 or 2 blocks) A 76 (3 or 4 blocks) Illuminated Pushbuttons M3.5 Terminal Screw Full Voltage ø24 ø40 ø35 B Panel Thickness 0.8 to 7.5 M3 Terminal Screw 5.5 23 40 40 9 9 Dimension B Ø 0.936" (24mm) Ø 0.936" (24mm) Extended w/Full Shroud 0.741" (19mm) 0.761" (19.5mm) Ø 0.936" (24mm) Ø 0.936" (24mm) Ø 1.56" (40mm) Mushroom Pushlock Turn Reset, Push-Pull *0.975" (25mm) **0.975" (25mm) Ø 1.56" (40mm) Ø 1.56" (40mm) Pilot Lights Full Voltage ø25 *Dimension when operator is in reset position. **Dimension when operator is in pull position. A:29.5 B:64.5 Selector Switches Knob Panel Thickness 0.8 to 7.5 90° 5.5 23 53 (1 or 2 blocks) 5.5 40 45° 21 76 (4 blocks) 5.5 40 21.5 90° M3.5 Terminal Screw 45° 45° ø40 23 53 (1 or 2 blocks) 76 (4 blocks) 40 22 Panel Thickness 0.8 to 7.5 90° M3.5 Terminal Screw 45° ø40 45° ø35 M3.5 Terminal Screw 9 Key Lever Panel Thickness 0.8 to 7.5 Panel Thickness: 0.8 to 7.5 mm 45° 23 9 53 (1 or 2 blocks) 16.5 ø40 Note: M3.5 Terminal Screw M3.5 Terminal Screw ø40 0.975" (25mm) 0.995" (25.5mm) Flush w/Full Shroud ø35 Dimension A ø35 Illuminated Pushbuttons 24 63 (2 blocks) 86 (4 blocks) A 97.5 (2 blocks) 120.5 (4 blocks) ø40 Panel Thickness 0.8 to 7.5 M3 Terminal Screw ø35 M3.5 Terminal Screw w/AC Adapter w/Transformer ø35 40 38 76 (4 blocks) Illuminated Knob Panel Thickness 0.8 to 7.5 (including nameplate) 5.5 90° 4 5° 45 ° ø40 M3 Terminal Screw ø35 M3.5 Terminal Screws ø25 Switches & Pilot Devices A4 Pushbuttons Panel Thickness 0.8 to 7.5 M3.5 Terminal Screw 40 23 63 (2 blocks) 9 A: 86 (4 blocks) B: 97.5 (2 blocks), 120.5 (4 blocks) A4-192 28 www.idec.com All measurements in mm. USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Switches & Pilot Devices ø30mm - TWTD Series Dimensions — TWTD Series con’t Selector Switches Panel Cut-Out Ø 0.195"(5mm) 1. *Jumbo Mushroom < 2.61" (66mm) 2. Minimum mounting centers are applicable to switches with one stack of contact blocks. When mounting two stacks of contact blocks, minimum centers should allow for access to wiring. 3. The Ø 0.195" (Ø 5mm) recess is necessary when either the nameplate or anti-rotation ring is used. Ø 1.20" (30.5mm) > 1.95" (50mm)* 0.33" (8.4mm) Cut-out is the only difference between TW and TWTD 3.66" (93mm) 2.76" OGL-31 Anti-Rotation Ring OC-31 Pushbutton Clear Boot 3.25" (82.5mm) 1.18" (30mm) (70mm) 1.76" 0.398" (10.2mm) Ø1.27" (Ø32.6mm) Accessory Dimensions OL-KL1 Lock-Out Adaptor Ø1.07" (Ø27.4mm) Flush: 0.702" (18mm) Extended: 0.858" (22mm) (44.8mm) 3.66" (2.62mm) 0.31" 1.97" (50mm) OB-31 Mounting Hole Rubber Plug (8mm) 1.16 Ø0.858" (22mm) (29.5mm) 0.137" (3.5mm) Ø1.13" (Ø29mm) 0.137" (3.5mm) Ø0.975" (Ø25mm) Finger-Safe Cover N-VL3 N-VL2 N-VL4 0.68" (17.2mm) N-VL2 0.61" (15.5MM) 1.51" (38.4MM) N-VL3 0.94" (24mm) 0.19" (4.7mm) 0.41" (10.5mm) 1.71" (18MM) 1.5" (38mm) 0.06" (1.4mm) 0.55" (14mm) 1.51" (38.4mm) 0.26" (6.5mm) N-VL4 ( R 0. 3 . 13 2M " M ) 0.87" (22mm) 0.71" (18mm) 0.94" (24MM) ( 6 0.2 . 2 4" m m ) 1.22" (31mm) (6 0.2 .2 4" m m ) 1.20" (30.4mm) 0.63" (16mm) APD-PVL .413" (10.5mm) .354" (9mm) 1.45" (37mm) 2m m) (6 . 1.26" (32mm) APD-PVL 6" 1.73" (44mm) .25 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-193 Switches & Pilot Devices 1.64" (42mm) A4 Oiltight Switches & Pilot Devices ø30mm - TWTD Series Instructions — TWTD Series Adjustment for Panel Thickness Switches & Pilot Devices A4 Each unit is shipped with several waterproof gaskets which are 0.06" (1.5mm) and 0.12" (3mm) thick. Combine the gaskets for a dimension approximately equal to panel thickness and install between the bezel and the body of the unit. Installation of LED Illuminated Units—Transformer units are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. Use diode with AC power supply to protect against reverse polarity. Use with DC power supply to protect against surges and noise. Terminal X1 A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. LED Terminal X2 Diode Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. Application Example For Push-To-Test Pilot Light A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/LED circuit. Thrust Washer Panel Cut-Out Unit Trim Washer Transformer/AC-Adapter Circuit Nameplate Start Stop M2 C L NC M2 NO T Selector Switches Test Pilot Light The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TWHC1) into the Standard Operating Positions. L Full Voltage Circuit Standard operation positions 2-Position, 90° 3-Position, 45° Start OLS Stop M 1 0 2 1 L 2 L M Non-Illuminated 3-Position Operators 1 0 1 2 0 NO T 1 C NC Test Pilot Light 0 2 2 Installation of TWTD Series Units TWTD Pilot Lights TWTD Illuminated Pushbuttons, TWTD Selector Switches (Transformer or Full Voltage) Terminal X1 = Positive Terminal X2 = Negative A4-194 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Cam Switches ø30mm - CS Series CS Series — Heavy Duty Cam Switches Rated Thermal Current AC Break Current Resistive Break Current DC Break Current Inductive Make Current (A) Electrical Life Mechanical Life A4 Switches & Pilot Devices Contact Ratings Key features of the CS Series include: • Wide variety of heavy-duty oiltight cam switches • Operators available up to 12 positions • Switches made with a double circuit contact block • Contact blocks rated 600V, 10A • Ideal for ammeter/voltmeter applications • Built to order — not available in subcomponents • UL listed and CSA certified • NEMA 4, 13 CSA Certified UL Listed File No. LR48366 File No. E68961 10A 120V/5A 240V/3A 480V/2A 24V/8A 110V/8A 220V/1A 600V/1A 440V/0.45A 24V/5A 110V/1.2A 220V/0.45A 440V/0.20A Rated amperage x 1.1 500,000 operations minimum (at full rated load) 5,000,000 (at no load) CS Series Operator Series Maximum Contacts To Be Mounted Handle Styles 1 to 10 decks; Up to 20 contacts YB, SB, PB, FB 1 to 10 decks; Up to 20 contacts HB or standard key Up to 12 Up to 8 Up to 6 Up to 4 2 or 3 1 to 10 decks; Up to 20 contacts YB, SB, PB, FB Only 3 1 to 3 decks; Up to 6 contacts YB, SB, PB, FB Cam Angle Position 30° 45° 60° 90° 45° 30° 45° 60° 90° 45° Up to 12 Up to 8 Up to 6 Up to 4 2 or 3 Up to 12 Up to 8 Up to 6 Up to 4 2 or 3 UCSQO 30° 45° 60° 90° 45° UCSQM 45° Spring return ACSNO ACSNK Appearance 1. It is recommended to use spring return (SR) for a maximum of six contacts. 2. Two identical keys come with ACSNK unit. Specify “H" for handle key option. 3. For handle styles, see page A4-200. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-195 Oiltight Cam Switches ø30mm - CS Series CS Series – Heavy Duty Cam Switches Switches & Pilot Devices A4 Assembled Oiltight Cam Switches ACSNO – 3 6 6 – ( ) S B - C3013 Series ACSNO = Standard Cam Switch (30mm) Contact Arrangement ACSNK = Key Cam Switch (30mm) arrangements, use designations on pages A4-197 and A4-198. 2. For custom contact arrangements, omit contact arrangement designation and complete the blank order form on the next page. UCSQO = Cam Switch (5 hole mounting) UCSQM = 3 Position Spring Return Cam Switch (5 hole mounting) Number of Levels (Decks) 1 through 10 Note: One level contains two independent contacts.* Number of Positions 2 through 12 Angle 3 = 30° (12 position max) 4 = 45° (8 position max) 6 = 60° (6 position max) 9 = 90° (4 position max) 1. For standard contact Handle YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large HB = Handle Key (ACSNK only) Blank = Standard Key (ACSNK only) Spring Return Action Blank: Maintained RO = Spring return from left (2, 3 or 4position, 45° only) OR = Spring return from right (2, 3 or 4 position, 45° only) RR = Return from right and left (3 pos, 45° only) 1. *Contact blocks may contain two independent contacts, (a four position switch with four independent contacts only requires two contact blocks). 2. *Caution: switches with 180° or more of rotation may require separate blocks for each contact due to cam overlapping. Contact IDEC for details. 4. Key removable in every 45º position (45, 90, 180, 225, 270, 315, 360). A4-196 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Cam Switches ø30mm - CS Series Contact Arrangements Standard Arrangements Terminal Numbers 3 4 1 A4 2 1 2 C-1001 C-1002 C-1005 C-1008 3 4 3 4 3 4 3 4 3 1 2 1 2 1 2 1 2 1 1 2 1 2 C-2001 C-1014 C-2002 1 2 3 1 2 C-2006 2 1 C-2008 C-2004 4 0 2 C-2009 C-2027 7 8 7 8 7 8 7 8 7 8 7 8 7 8 5 6 5 6 5 6 5 6 5 6 5 6 5 6 3 4 3 4 3 4 3 4 3 4 3 4 3 4 1 2 1 2 1 2 1 2 1 2 1 2 1 1 2 1 2 1 0 2 C-3001 1 2 3 4 1 2 3 C-3002 C-3005 1 2 3 4 C-3013 2 1 2 3 4 5 C-3016 11 12 11 12 11 12 11 12 11 12 9 10 9 10 9 10 9 10 9 10 7 8 7 8 7 8 7 8 7 8 5 6 5 6 5 6 5 6 5 6 3 4 3 4 3 4 3 4 1 2 1 2 1 2 1 1 2 4 3 2 1 1 2 3 1 1 2 3 C-4001 15 5 6 2 1 2 3 4 5 C-4002 15 16 13 14 13 14 11 12 11 12 9 10 9 10 7 8 7 8 5 6 5 6 3 4 3 4 1 2 1 2 1 2 3 4 5 6 7 C-6001 8 C-6002 20 23 24 23 24 18 21 22 21 22 16 19 20 19 20 17 18 17 18 15 16 14 13 4 15 C5001 17 3 16 1 2 3 4 19 2 11 12 15 16 9 10 13 14 13 14 7 8 11 12 11 12 6 9 10 9 10 4 7 8 7 8 2 5 6 5 6 3 4 3 4 1 2 1 5 3 1 1 2 3 1 2 3 4 www.idec.com 2 1 2 3 4 5 6 7 8 9 10 11 12 USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-197 Switches & Pilot Devices Position Numbers Oiltight Cam Switches ø30mm - CS Series Contact Arrangements con’t Ammeter Switching C-1012 C-4007 C-4003 C-6003 Switches & Pilot Devices A4 Voltmeter Switching C-2022 C-3008 C-3009 C-3007 A4-198 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Cam Switches ø30mm - CS Series Order Form (Custom Contact Arrangement) ( ) Series ACSNO ACSNK UCSQO UCSQM A4 * Note: One Deck can drive two independent contacts. Handle Number of Positions Unit Angle 30° only ACSNO 30° or 45° only ACSNK* 30°, 45° or 60° UCSQO 30°, 45°, 60°, 90° UCSQM 45° only * ACSNK keys only remove at 45°. Positions Spring Return 9, 10, 11, 12 7 or 8 5 or 6 Blank = Maintained RO = Spring return from left (3 or 4 position, 45° only) OR = Spring return from right (3 or 4 position, 45° only) RR = Return from right and left (3 position, 45° only) UCSQM is available in spring-return version only. Angle 3 = 30° 4 = 45° 6 = 60° 9 = 90° 2, 3, or 4 3 only Contact Arrangement Table Cams Terminal No. 1 2 3 4 5 Position 6 7 Switches & Pilot Devices *Number of Decks Specify Qty = 1, 2, 3, 4, 5, 6, 7, 8, 9, or 10 ACSNO, UCSQO, UCSQM: YB = Knob, Small SB = Lever, Small PB = Lever, Large FB = Knob, Large ACSNK: HB = Handle Key (option) Blank = Standard Key For handle styles, see page A4-200. 8 9 10 11 12 1 and 2 3 and 4 5 and 6 7 and 8 9 and 10 11 and 12 13 and 14 15 and 16 17 and 18 19 and 20 21 and 22 23 and 24 25 and 26 27 and 28 29 and 30 31 and 32 33 and 34 35 and 36 37 and 38 39 and 40 Deck 1 Deck 2 Deck 3 Deck 4 Deck 5 Deck 6 Deck 7 Deck 8 Deck 9 Deck 10 To specify non-standard arrangements (designation not on preceding pages), fill in this table using the following symbols. X = Closed contact (break before make) O = Open contact X X = Overlapping contact (remain on when switch is moved between two positions) Specifying Nameplate (Optional) 12 1 2 11 3 10 4 9 5 8 7 6 45° 1 90° 30° 60° 8 1 Specifying Legends 2 7 3 6 5 4 1 2 6 4 2 3 5 4 www.idec.com 3 If no engraving information is provided, a blank nameplate will be supplied. Position 1 _________________________ 7 _________________________ 2 _________________________ 8 _________________________ 3 _________________________ 9 _________________________ 4 _________________________ 10 ________________________ 5 _________________________ 11 ________________________ 6 _________________________ 12 ________________________ USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-199 Oiltight Cam Switches ø30mm - CS Series Accessories — CS Series Replacement Handles Switches & Pilot Devices A4 Part Number CSH-YB CSH-SB CSH-PB CSH-FB CSH-H2B Dimensions 0.79"D x 1.61"H 0.79"D x 1.97"H 1.58"D x 1.97"H 1.58"D x Ø 1.97" 0.95"D x 2.28"H Applicable Models ACSNO, UCSQO, UCSQM ACSNK Replacement Nameplates Size & Shape ❑ 2.52" (64mm) Black Aluminum Part Number CQ CQM CQN Applicable Models UCSQO UCSQM ACSNO, ACSNK 1. Extra cost for engraving, 3/16" min. letter height. For legends with more than ten characters, consult IDEC. 2. Blank nameplates are supplied with all cam switches (they need not be ordered separately). Wiring Clips Part Number Contact Block Jumpers CJ-1 Between cams CJ-2 Same cam Replacement Keys Part Number K301 Pair of keys (#301) A4-200 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Oiltight Cam Switches ø30mm - CS Series Dimensions/Terminal Arrangements/Mounting Holes ACSNO A4 Switches & Pilot Devices Terminal Arrangement ACSNK Mounting Holes ACSNO ACSNK UCSQO UCSQO UCSQM UCSQM www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-201 Mono-Lever Switches ø30mm - ARN Series ARN Series — Mono-Lever Switches Mono-Lever Switches Ø 1-13/64" (30mm) Contact Blocks Rated for 600V, 10A • Maintained and spring-return modes available. • Models available with interlock mechanism to prevent inadvertent actuation. CSA Certified File No.LR48366 UL Listed File No. E68961 Specifications Switches & Pilot Devices features of the ARN Series include: A4 Key • Available in 2–, 3–, and 4–positions. Operating Temperature -25˚to 50˚C (without freezing) Insulation Resistance 100MΩ Rated Voltage: Current Contact Rating 110VDC: 3A 24V AC/DC: 10A 120VAC: 10A 240VAC: 6A 480VAC: 2A 600VAC: 1A Insulation Voltage 600V AC/DC Rated Thermal Current 10A Electrical Life Over 500,000 operations Part Numbering Guide (Assembled) Part Numbering Guide: Assembled Mono-Levers Example: Part Number ARN4-1012-10.00.02.11-B ARN ➀ Type - 4 - 1012 ➁ No. of 10.00.02.11 ➂ Lever Contact Blocks ➃ Contact Action Arrangement Description ➀ Type Standard Lever Short Lever Interlocking Lever ➁ No. of Contact Blocks — ➂ Lever Action ➃ Contact Arrangement A4-202 Blocked Maintained Spring Return No contacts 1 NO contact 1 NC contact 1 NO and 1 NC contact 2 NO contacts www.idec.com Code ARN ARNS ARNL 1 2 3 4 0 1 2 00 10 01 11 20 Remarks Interlocking lever prevents inadvertent operation. Each contact block contains two independent contacts. Specify in this order: Up.Right.Down.Left Specify the number of contacts to be activated in all active (nonblocked) positions: Up.Right.Down.Left USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Mono-Lever Switches ø30mm - ARN Series Mono-Lever Switches (Sub-Assembled) Contact Block + Operator + Complete Part A4 Switches & Pilot Devices Part Numbers: Standard Mono-Lever Operators Operator Type Lever Operation Mode Part Number Standard Lever Short Lever Interlocking Lever 2-Position manual return 3-Position manual return 4-Position manual return ARN0-1010-B ARN0-1110-B ARN0-1111-B 2-Position spring return 3-Position spring return 4-Position spring return ARN0-2020-B ARN0-2220-B ARN0-2222-B 2-Position manual return 3-Position manual return 4-Position manual return ARNS0-1010-B ARNS0-1110-B ARNS0-1111-B 2-Position spring return 3-Position spring return 4-Position spring return ARNS0-2020-B ARNS0-2220-B ARNS0-2222-B 2-Position manual return 3-Position manual return 4-Position manual return ARNL0-1010-B ARNL0-1110-B ARNL0-1111-B 2-Position spring return 3-Position spring return 4-Position spring return ARNL0-2020-B ARNL0-2220-B ARNL0-2222-B Part Numbers: Contact Blocks Contact Arrangement Part Number 2NO contacts 1NO & 1NC contact 2NC contacts 1NO early make contact BR-1E BR-2E BR-3E BR-1EM To calculate the number of contact blocks required, add the number of NO and NC contacts on each pair of adjoining positions (up + right, right + down, down + left, and left + up). The largest of the four sums is the number of contact blocks required. Up to four contact blocks can be mounted. Replacement Parts Item Bellows Part Number ARN0, ARNS0 (standard & short lever) ARN-BL ARNL0 (Interlocking) ARNL-BL (comes in 2 pieces) All Models Knob (ball) ARNB-B Knob (ball) www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A4-203 ø30mm - ARN Series Mono-Lever Switches Dimensions — ARN Series ARNO ARNSO Switches & Pilot Devices A4 Mounting Hole ARNLO ARNO ARNSO ARNLO A4-204 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices Miniature ø8mm A8 Series A8 Series — Miniature Switches and Pilot Devices: 8mm Contact Ratings A5 Switches & Pilot Devices Specifications Key features of the 21/64" (8mm) A8 series Switches and Pilot Devices include: • 21/64" (8mm) round mounting hole • Compact Design Saves Space • Bright and Vivid Illumination • Choice of Shapes and Functions • Gold Clad Silver Contacts for reliable low level switching • Snap action contacts • IP40 (Dustproof) Construction CSA Certified UL Recognized File No. LR21451 File No. E55996 LED Lamp Life 50,000 hours approximately (reduced to half of original intensity) Contact Configuration SPDT Maximum Voltage 250V AC/DC Thermal Current 3A Contact Material Gold-clad Silver Terminal Style Solder Tab Terminal Operating Temperature –25° to +55°C (no freezing) Operating Humidity 45 to 85% RH Contact Resistance 50mΩ maximum (initial value) Insulation Resistance 100MΩ minimum (500V DC megger) Vibration Resistance 5 to 55Hz, 0.75mm amplitude Shock Resistance Damage limits: 500m/sec2 (approx. 50G) Operating extremes: 200m/sec2 (approx. 20G) Electrical Life 100,000 operations minimum Mechanical Life Maintained: 100,000 (1200 operations/hour) Momentary: 200,000 minimum Degree of Protection IP40 Enclosed/Dustproof Soldering Temperature 20W/5 seconds or 260°C/3 seconds Dielectric Strength Switch Unit: 2,000V AC, 1 min. between live/dead part and terminals of different poles; 1,000V AC, 1 minute between terminals of the same pole; 1,500V AC, 1 minute between contact and lamp terminals. Illumination Unit: 2,000V AC, 1 min. between live part/ground Operating Voltage AC 50/60Hz DC Resistive 24V 120V 240V — 1.0A 0.5A Inductive — 0.7A 0.5A Resistive 1.0A 0.2A — Inductive 0.7A 0.1A — 1. AC Inductive Load, PF = 0.6 – 0.7; DC Inductive Load, L/R = 7. 2. Minimum applicable load (reference value) is 5V AC/DC 3mA (applicable range is subject to the operating conditions and load). www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-205 Miniature ø8mm A8 Series Miniature Switches & Pilot Devices AB8 Non-Illuminated Pushbuttons (Assembled) Part Numbers: Non-Illuminated Pushbuttons Style Switches & Pilot Devices A5 Contact Part Numbers Momentary Maintained Round SPDT AB8M-M1-① AB8M-A1-① SPDT AB8Q-M1-① AB8Q-A1-① SPDT AB8H-M1-① AB8H-A1-① Square Rectangular 1. In place of ①, specify button color code from the table below. 2. For accessories, see page A5-208. 3. For dimensions, see page A5-209. ① Button Color Code A5-206 www.idec.com Color Code Black B Green G Red R Blue S White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices Miniature ø8mm A8 Series AL8 Illuminated Pushbuttons and Pilot Lights (Assembled) Part Numbers: LED Illuminated Pushbuttons and Pilot Lights Pushbutton Part Number Style Contact Momentary Maintained Pilot Light Part Number A5 Round AL8M-M11-➁ AL8M-A11-➁ Switches & Pilot Devices SPDT AL8M-P1-➁ ➁ Lens/LED Color Code Color Code Square SPDT AL8Q-M11-➁ AL8Q-A11-➁ AL8Q-P1-➁ Rectangular SPDT AL8H-M11-➁ AL8H-A11-➁ Amber A Green G Red R White W Yellow Y AL8H-P1-➁ 1. In place of ➁, specify lens color code from table on the right. 2. A replaceable LED lamp is included with the operator. 3. Because the LED lamp does not contain an internal current limiting resistor, an external resistor must be added. For recommended values, see table below. 4. For accessories, see page A5-208. 5. For dimensions, see page A5-209. Part Numbers: Replacement LEDs Lens Color LED Lamp Part Number Amber Amber LAD-SA Green Green LAD-SG Red Red LAD-SR White Yellow* LAD-SY Yellow Yellow LAD-SY LED Voltage and Recommended Current Limiting Resistor Voltage External Resistor 5V DC 6V DC 12V DC 24V DC 150Ω, 1/2W 200Ω, 1/2W 510Ω, 1W 1.1kΩ, 1W * White units use a white lens and a yellow LED. LED Specifications LED Lamp Ratings Forward LED Current Lamp If Forward Voltage (Nominal) Vf Reverse Voltage Vr Operating Voltage & External Current Limiting Resistor (Recommended Value) Amber 20mA 2.2V 4V 5V DC: 150Ω, 1/2w Green 20mA 2.1V 4V 6V DC: 200Ω, 1/2w Red 20mA 1.7V 4V 12V DC: 510Ω, 3/4w Yellow 20mA 2.2V 4V 24V DC: 1.1kΩ, 3/4w When LED lamps are used at voltages other than those stated above, external resistor value, R, is determined by the following formula: R = (Operating Voltage – Vf) / If www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-207 Miniature ø8mm A8 Series Miniature Switches & Pilot Devices Accessories — A8 Series: 21/64" (8mm) Appearance Locking Ring Wrench Switches & Pilot Devices A5 Description Used With Part Number Made of metal. Used for tightening plastic locking ring during installation. Tightening torque should not exceed 3kgf-cm All units MT-004 Made of metal. Used for removing lens or button from the housing Illuminated pushbuttons and pilot lights MT-101 Made of rubber. Used for removing and replacing LED lamps in illuminated units Illuminated pushbuttons and pilot lights OR-66 Round & square units AL-K8 Rectangular units AL-KH8 All units AL-V8 Lens Removal Tool Lamp Holder Tool Switch Guard Used to avoid operating the pushbutton inadvertently. Cover flips open 90˚. Provides IP40 protection Terminal Cover Made of translucent nylon. Fits over and shields the terminals Adaptor Socket Plug-on adaptor with solder terminals, allows easy control unit replacement. AL-C8 All units Plug-on adaptor with PCB terminals, allows easy control unit replacement. AL-C8V Mounting Hole Plug Made of rubber. Fills unused mounting holes to provide IP65 protection Extra panel cutouts AL-B8 Replacements LEDs LAD-SR (red) LED lamp is included in every illuminated control unit. Replacement lamp is ordered separately. External current limiting resistor required. LAD-SG (green) Illuminated units and pilot lights LAD-SA (amber) LAD-SY (yellow) Illuminated pushbuttons & pilot lights Replacement Engraving Inserts Replacement Lenses Illuminated pushbuttons & pilot lights Replacement Buttons Non-Illuminated buttons 1. In place of ①, specify Button Color Code from the table on the right. 2. In place of ➁, specify Lens Color Code from table on the right. A5-208 www.idec.com ① Button Color Code Color Code Color Black B Blue Green G White Red R Yellow Code S W Y Round Square Rectangular AL8M-W AL8Q-W AL8H-W Round AL8M-LK1-➁ Square AL8Q-LK1-➁ Rectangular AL8H-LK1-➁ Round Square Rectangular AB8M-BK1-① AB8Q-BK1-① AB8H-BK1-① ➁ Lens/LED Color Code Color Amber Green Red White Yellow Code A G R W Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Switches & Pilot Devices Miniature ø8mm A8 Series Dimensions — A8 Series: 21/64" (8mm) A∆8 Pushbuttons Terminal 0.3t × 0.8W 6.3 33 Ø 8mm (+0.2, -0) 2.5 33 Panel Cut-Out (not drawn to scale) Rectangular Ø 0.315" (+0.008, –0) A5 0.354" 8.8 5 17 Switches & Pilot Devices 17 2.5 (9mm) 3 0.472" Solder Terminal (AL-C8) PC Board Terminal (AL-C8V) (12mm) Round/Square Ø 0.315" (+0.008, –0) Ø 8mm (+0.2, -0) Terminal Arrangement (TOP) 2.5 6.3 NC 0.354" (9mm) Lamp Terminal (+) 5-1.0 0 hole COM Lamp Terminal (–) (BOTTOM VIEW) (PC Board Mounting Hole Layout) 0.354" (9mm) Switch Guard, Ø 21/64" (8mm) 0.839" (21.5) Square Round 0.354" 0.488" (12.5) (9mm) AL-KH8, Ø 21/64" (8mm) Rectangular AL-K8, Ø 21/64" (8mm) Round and Square 0.472" 0.354" 0.354" (12mm) (9mm) (9mm) Terminal Arrangement (Bottom View) NC 0.566" (14.5) Rectangular Panel Thickness: 0.019 to 0.195" (0.5 to 5.0) 0.332" (8.5) 0.39" (10) 0.683" min (17.5min) 0.234" (6) 0.566" (14.5) +0.2 2.5 NO 0.332" (8.5) 0.683" min (17.5min) 0.234" (6) 0.507" min (13min) 0.429" min (11min) NO 0.468" (12) COM (+) Lamp (–) Lamp Terminal Sockets AL-C8, Ø 21/64" (8mm), Solder 1.287" (33) 0.246" (6.3) 0.098" (2.5) Terminal Cover AL-V8, Ø 21/64" (8mm) 0.663" (17) 0.677" (17.3) Ø 0.355" (Ø 9.1) 1.307" (33.5) 0.098" (2.5) 0.343" (8.8) 0.195" (5) AL-C8V, Ø 21/64" (8mm), PCB Terminal: 0.012 x 0.031" (0.3 x 0.8) 0.246" (6.3) 1.287" (33) 0.098" (2.5) 0.098" (2.5) 0.663" (17) +0.008 0.117" (3) 5 - Ø 0.039"-0 +0.2 (Ø 1.0 -0 ) Holes PC Board Drilling Layout Bottom View www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-209 Miniature Pilot Lights Miniature ø8-16mm AP Series AP Series — Miniature Pilot Lights Miniature Pilot Lights with Super Bright LEDs Specifications AP8 AP1 CSA Certified File No. LR92374 UL Recognized File No. E68961 Optional Adaptors/Converters Switches & Pilot Devices A5 Key features of AP series include: • Long service life, low maintenance • Space saving miniature style • Dome or flat lens models • Built-in current-limiting resistor and reverse polarity protection diode • Five illumination colors: red, green, amber, yellow, and white • AC adaptor (120V AC and 240V AC) and DC-DC Converter (110V DC) options on 12mm and 16mm units Lamp Built-in LED with current limiting resistor Operational Voltage 6, 12, 24VDC (full voltage), 110/120, 220/240VAC, (transformer) 110VDC (with converter) Current Ratings AP8: 6VDC/18mA, 12VDC/18mA, 24VDC/12mA AP1: 6VDC/18mA, 12VDC/18mA, 24VDC/12mA AP2: 6VDC/33mA, 12VDC/22mA, 24VDC/11mA AP6: 6VDC/33mA, 12VDC/22mA, 24VDC/11mA Operating Temp. -20°C to +55°C Operating Humidity 45 to 85% RH Insul. Resistance 100MΩ min. (500V DC megger) Between live and dead parts Rev. Withstand Voltage AP2/AP6: 100V AP1/AP8: 200V Solder Terminal Soldering 260°C maximum (5 sec.) Degree of Protection AP8: IP40 (dustproof) Other Series: IP65 (oiltight) AP2 AP6 AC Adaptor DC-DC Converter Applicable Units AP2 & AP6 (with 6V LED only) Operating Voltage 110/120VAC 50/60 Hz 220/240VAC 50/60 Hz 110V DC (90 to 140V DC) Power Consumption 1.6 VA maximum 1W maximum Insulation Voltage 250 V AC 140V DC Insulation Resistance 10MΩ min. (500V DC megger) Between live and dead parts Dielectric Strength 2,000V AC, 1 minute Between live/dead parts 2,000V AC, 1 minute Between terminals 2,000V AC, 1 minute Between live/dead parts 1,500V AC, 1 minute Between terminals Available as one piece only (replacement LEDs are not available). A5-210 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Pilot Lights Miniature ø8-16mm AP Series Miniature Pilot Lights (Assembled) Part Numbers: AP Miniature Pilot Lights Appearance Lens Style AP8 Series - Ø 8mm Part Numbers Dome 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP8M266-➁ AP8M211-➁ AP8M222-➁ Flat 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP8M166-➁ AP8M111-➁ AP8M122-➁ Dome 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP1M266-➁ AP1M211-➁ AP1M222-➁ 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP1M166-➁ AP1M111-➁ AP1M122-➁ AP1 Series - Ø 10mm Flat AP2 Series - Ø 12mm 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP2M266-➁ AP2M211-➁ AP2M222-➁ Flat 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP2M166-➁ AP2M111-➁ AP2M122-➁ Dome 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP6M266-➁ AP6M211-➁ AP6M222-➁ Flat 6V DC +/- 5% 12V DC +/- 10% 24V DC +/- 10% AP6M166-➁ AP6M111-➁ AP6M122-➁ Dome AP6 Series - Ø 16mm A5 Switches & Pilot Devices Operating Voltage ➁ Color Code Color Code Amber A Green G Red R White W Yellow Y 1. In place of ➁, specify the color code. 2. For dimensions, see page A5-212 3. For accessories, see page A5-212. Part Numbers: Optional AC Adaptors and DC-DC Converters (for AP2 and AP6 only) Part Numbers Appearance Style Voltage Used with Used with AP2 Series AP6 Series AC Adaptor 110/120V AC 220/240V AC AP2-0126D AP2-0246D AP6-0126D AP6-0246D DC-DC Converter 110V DC (90–140V DC) AP2-016DD AP6-016DD Secondary Voltage = 6V 1. Optional AC adaptors and DC-DC converters snap onto the back of AP2 or AP6 pilot lights. 2. AC Adaptors and DC-DC Converters step down to 6V. 3. For dimensions, see page A5-213. www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-211 Miniature Pilot Lights Miniature ø8-16mm AP Series Accessories — AP Series Appearance Switches & Pilot Devices A5 Description Locking Ring Wrench Made of metal. Used for tightening plastic locking ring during installation. Tightening torque should not exceed 3kgf-cm Mounting Hole Plug Made of rubber. Fills unused mounting holes to provide IP65 protection Transformer Removal Tool Replacement Lenses Lenses (included with all units). Replacement Engraving Inserts Allow legends under flat lenses (included with all flat lens models). Used With Part Number Ø 16mm units MT-001 Ø 12mm units MT-002 Ø 10mm units MT-003 Ø 8mm units MT-004 Unused 8mm panel cutouts AL-B8 Unused 10mm panel cutouts AL-B1 Unused 12mm panel cutouts AL-B2 Unused 16mm panel cutouts AL-B6 AP2 & AP6 snap on transformer & DC-DC converter MT-100 AP1M Flat AP1M-L1-➁ AP1M Dome AP1M-L2-➁ AP2M Flat AP2M-L1-➁ AP2M Dome AP2M-L2-➁ AP6M Flat AP6M-L1-➁ AP6M Dome AP6M-L2-➁ AP1M Flat AP1M-P1-W AP2M Flat AP2M-P1-W AP6M Flat AP6M-P1-W In place of ➁, specify the Lens Color Code. ➁ Lens Color Code Color Code A5-212 www.idec.com Amber A Green G Red R White W Yellow Y USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC Miniature Pilot Lights Miniature ø8-16mm AP Series Dimensions — AP Series Pilot Lights (AP Series) Style AP8 Dome Flat Dome AP2 Flat Dome AP6 w/ Adaptor or Converter Flat Ø 0.319" (+0.0118, –0) 8.1mm (+0.3, –0) Ø 0.398" (+0.0118, –0) 10.1mm (+0.3, –0) Ø 0.480" (+0.0118, –0) 12.2mm (+0.3, –0) Outside Dimension Ø 0.386" (9.8mm) Ø 0.472" (12mm) Ø 0.551" (14mm) ❑ 0.709" (18mm) Panel Thickness: 0.8 to 6 mm Gasket Round Extended ø14 7 ø15.6 + 1.5 2.2 5 1.5 ø12 2.2 - 21.5 5.5 5.5 21.5 8 11.5 Panel Cut-out ø15.6 29.5 Panel Cut-out Round Flush ø12 29.5 13.5 ø14 Round Flush ø18 ❑ 0.709" (18mm) Ø 0.709" (18mm) Panel Thickness: 0.8 to 6 mm Gasket Round Extended ø18 Ø 0.638" (+0.0118, –0) 16.2mm (+0.3, –0) +0 .2 +0 0 ø1 5.5 2 6. 2 ø1 5.5 .2 .2 0 9.5 9.5 When using the AC adapter unit (When using the DC-DC converter unit) M3 terminal screw AC adapter unit (or DC-DC converter unit) AC adapter unit (or DC-DC converter unit) M3 terminal screw + Terminal + Terminal 18 X2 X2 18 TOP X1 TOP X1 When using the AC adapter unit (When using the DC-DC converter unit) 71 1.3 2.2 Panel Thickness: 0.8 to 6 mm 2.8 3 ø8 + 8 5.5 9.5 29.5 8 29.5 Panel Cut-out +0 0 .2 ø9.8 Round Flush 5.5 ø1 0. 1 .1 +0 .2 0 ø10 21.5 ø8 Panel Cut-out Round Flush ø12 ø9.8 - 21.5 5.5 ø8 2.8 Gasket Round Extended 4 ø10 ø12 5.5 – Terminal 1.5 2.2 1.5 Gasket 10 18 1.3 – Terminal Panel Thickness: 0.8 to 6 mm Round Extended 58.7 71 18 58.7 8.5 9.5 www.idec.com USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC A5-213 A5 Switches & Pilot Devices Panel Cut-out w/ Adaptor or Converter Dome - + Flat AP1
HW4S-2TF10 价格&库存

很抱歉,暂时无法提供与“HW4S-2TF10”相匹配的价格&库存,您可以联系我们找货

免费人工找货