0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
70170-D

70170-D

  • 厂商:

    MACROMATIC

  • 封装:

  • 描述:

    SOCKET

  • 数据手册
  • 价格&库存
70170-D 数据手册
Industrial Control & Monitoring Products Alternating Relays Time Delay Relays Phase Monitor Relays Voltage Monitor Relays Current Monitor Relays Your Choice for Industrial Controls For 30 years, Macromatic has been producing industrial control & monitoring products. All are engineered and manufactured in our U.S.-based facility in Menomonee Falls, Wisconsin (a Milwaukee suburb), utilizing a timeproven quality system to produce products that consistently meet your requirements for function, availability & value. Who Uses Our Controls? A wide variety of challenges can be met by using our products. Our customer base includes OEM’s who specify Macromatic controls in their equipment, and end users who count on Macromatic precision and reliability for their own applications. Our products are used in a variety of industries such as machine tool, automotive, material handling, pulp & paper, food & beverage, transportation, communications, water/ wastewater and HVAC, among many. Where to Buy? We are pleased to offer our complete line of products in the United States and Canada through a network of Preferred Macromatic Distributors. We have partners with national, regional and local presence who stock and sell our products. Call us or visit us on the web to locate a distributor or sales representative near you. Need Technical Help? Have Special Applications? Do you need help selecting or applying one of our products? Don’t quite know what you need? Our team of engineers and technical advisors is available to help you address your specific needs. Whether by helping you decide which time delay relay function is required in your application or working with you on designing custom-engineered solutions for your particular need, we have the experience to help you one-on-one. Don’t hesitate to call us to discuss your particular application. Why Choose Macromatic Controls? Long known for their precision and reliability, Macromatic products are increasingly the choice of industrial design engineers for use in new equipment and are preferred by maintenance personnel as quality replacements in existing applications. We test each product twice before it is shipped, and all products have an extensive warranty period longer 2 than most other manufacturers (contact Macromatic for further details). Most standard and custom design products are UL recognized or listed and CSA approved. We have obtained UL Listing on our plugin products when used with our sockets. Many products now carry the CE Mark. What You Need, When You Need It Don’t wait for something you need now. Macromatic offers prompt delivery of standard products and can even deliver many non-standard orders within seven to ten days, all without any special expediting fees charged by many manufacturers. We are dedicated to being responsive, and that means you get what you need when you need it, not weeks or months from now. Contact us or one of our Preferred Distributors or Sales Representatives and we will provide you with an on-time solution. Want to Learn More? You can reach us at 800-238-7474 or e-mail us at whats-up@macromatic.com. Our customer service and technical assistance people are ready to help with your questions or special needs. Or you can visit us at www.macromatic.com. Product Index Index by Product Number ................................................................................................. 4 Phase Monitor Relays Product Summary ......................................................................................................... PCP Series Phase Reversal ......................................................................................... PLP Series Phase Loss & Phase Reversal .................................................................. PAP Series Phase Loss, Phase Reversal & Undervoltage ........................................... PMP Series Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage & Overvoltage .............................................................................. PMD Series Phase Loss, Phase Reversal, Phase Unbalance, Undervoltage & Overvoltage .............................................................................. 14-15 Current Monitor Relays NEW Product Summary ......................................................................................................... CM Series Standard ...................................................................................................... CO Series Overcurrent ................................................................................................. CU Series Undercurrent ................................................................................................ 17 18-19 20-21 22-23 5 6-7 8-9 10-11 12-13 Voltage Monitor Relays NEW Product Summary ......................................................................................................... 24 VM Series Over/Under Voltage (Fixed Time Delay on Drop-Out) .................................. 25, 27 VA Series Over/Under Voltage (Adjustable Time Delay on Drop-Out) ........................... 26-27 VW Series Voltage Band (Window) ............................................................................... 28-29 Time Delay Relays Product Summary ......................................................................................................... Definition of Timing Functions ........................................................................................ TR-5 Series Non-Programmable DPDT ........................................................................ TR-5 Series Non-Programmable 8 Pin SPDT ............................................................... TR-6 Series Time Ranger Programmable Multi-Range ................................................ SS-6 & -8 Series Compact Non-Programmable ........................................................... SS-4 Series Non-Programmable with Quick Connect Terminals .................................. TD-7 Series Time Ranger Digital-Set Programmable ................................................... 981 Series Time Ranger III Digital-Set Multi-Function Multi-Range ............................... Standard Modifications .................................................................................................. 30-31 32-33 34-37 38-39 40-43 44 45 46-47 48-49 50-51 Alternating Relays For 1 Switch Applications (SPDT& DPDT) ................................................................... For 2 Switch Applications (DPDT Cross-Wired) ........................................................... For 3 Switch Applications .............................................................................................. 52-53 54-55 56-57 Sockets & Accessories ..................................................................................................... 16 & 58 Since we continuously strive to improve and update our product offering, specifications are subject to change without notice. “Macromatic” & “Time Ranger” are Registered Tradenames of Macromatic Controls LLC 3 Index By Product Number Product * 70100 70166 70169-D 70170-D 70171-D 70200 70300 70310 70320 9816U1 ARP012A2 ARP012A2R ARP012A3 ARP012A3R ARP012A6 ARP012A6R ARP012A8 ARP012A8R ARP024A2 ARP024A2R ARP024A3 ARP024A3R ARP024A6 ARP024A6R ARP024A8 ARP024A8R ARP120A2 ARP120A2R ARP120A3 ARP120A3R ARP120A6 ARP120A6R ARP120A8 ARP120A8R ARP240A2 ARP240A2R ARP240A3 ARP240A3R ARP240A6 ARP240A6R ARP240A8 ARP240A8R CMKP01A22 CMKP01A28 CMKP01A62 CMKP01A68 CMKP05A22 CMKP05A28 CMKP05A62 CMKP05A68 CMKP10A22 CMKP10A28 CMKP10A62 CMKP10A68 CMP01A22 CMP01A28 CMP01A62 CMP01A68 CMP05A22 CMP05A28 CMP05A62 CMP05A68 CMP10A22 CMP10A28 CMP10A62 CMP10A68 COKP01A22 COKP01A28 COKP01A62 COKP01A68 COKP05A22 Page 16 & 58 16 & 58 16 & 58 16 & 58 16 & 58 16 & 58 48 48 48 48 52 52 54 54 52 52 56 56 52 52 54 54 52 52 56 56 52 52 54 54 52 52 56 56 52 52 54 54 52 52 56 56 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 20 20 20 20 20 Product * COKP05A28 COKP05A62 COKP05A68 COKP10A22 COKP10A28 COKP10A62 COKP10A68 COP01A22 COP01A28 COP01A62 COP01A68 COP05A22 COP05A28 COP05A62 COP05A68 COP10A22 COP10A28 COP10A62 COP10A68 CUP01A22 CUP01A28 CUP01A62 CUP01A68 CUP05A22 CUP05A28 CUP05A62 CUP05A68 CUP10A22 CUP10A28 CUP10A62 CUP10A68 PAP120 PAP208 PAP240 PAP400 PAP480 PCP1 PCP2 PLP120 PLP208 PLP240 PLP400 PLP480 PMD120 PMD208 PMD240 PMD400 PMD480 PMD600 PMDU PMP120 PMP208 PMP240 PMP480 PMPU SS-3062-xx SS-3066-xx SS-3068-xx SS-3162-xx SS-3166-xx SS-3168-xx SS-3262-xx SS-3266-xx SS-3268-xx SS-3362-xx SS-3366-xx SS-3368-xx SS-3562-xx SS-3566-xx SS-3568-xx SS-40222-xx Page 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 22 22 22 22 22 22 22 22 22 22 22 22 10 10 10 10 10 6 6 8 8 8 8 8 14 ** ** ** ** 14 14 12 ** ** ** 12 34 34 34 34 34 34 34 34 34 34 34 34 34 34 34 45 Product * SS-40228-xx SS-41622-xx SS-41628-xx SS-6262-xx SS-6266-xx SS-6268-xx SS-70166 SS-8062-xx SS-8066-xx SS-8068-xx SS-8162-xx SS-8166-xx SS-8168-xx SS-8562-xx SS-8566-xx SS-8568-xx SS-8762-xx SS-8766-xx SS-8768-xx TD-70221 TD-70222 TD-70226 TD-70228 TD-70521 TD-70522 TD-70526 TD-70528 TD-70821 TD-70822 TD-70826 TD-70828 TD-71521 TD-71522 TD-71526 TD-71528 TD-71621 TD-71622 TD-71626 TD-71628 TD-78121 TD-78122 TD-78126 TD-78128 TR-50221-xx TR-50222-xx TR-50226-xx TR-50228-xx TR-50521-xx TR-50522-xx TR-50526-xx TR-50528-xx TR-50821-xx TR-50822-xx TR-50826-xx TR-50828-xx TR-51321-xx TR-51322-xx TR-51326-xx TR-51328-xx TR-51361-xx TR-51362-xx TR-51366-xx TR-51368-xx TR-51521-xx TR-51522-xx TR-51526-xx TR-51528-xx TR-51561-xx TR-51562-xx TR-51566-xx TR-51568-xx Page 45 45 45 44 44 44 *** 44 44 44 ** ** ** 44 44 44 44 44 44 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 46 34 34 34 34 34 34 34 34 34 34 34 34 35 35 35 35 38 38 38 38 35 35 35 35 38 38 38 38 * The “-xx” suffix denotes the time range for non-programmable time delay relays. 4 Product * TR-51621-xx TR-51622-xx TR-51626-xx TR-51628-xx TR-51661-xx TR-51662-xx TR-51666-xx TR-51668-xx TR-51721-xx TR-51722-xx TR-51726-xx TR-51728-xx TR-51761-xx TR-51762-xx TR-51766-xx TR-51768-xx TR-51821-xx TR-51822-xx TR-51826-xx TR-51828-xx TR-51861-xx TR-51862-xx TR-51866-xx TR-51868-xx TR-51921-xx TR-51922-xx TR-51926-xx TR-51928-xx TR-51961-xx TR-51962-xx TR-51966-xx TR-51968-xx TR-53121-xx TR-53122-xx TR-53126-xx TR-53128-xx TR-55121-xx TR-55122-xx TR-55126-xx TR-55128-xx TR-56121-xx TR-56122-xx TR-56126-xx TR-56128-xx TR-56521-xx TR-56522-xx TR-56526-xx TR-56528-xx TR-60221 TR-60222 TR-60226 TR-60228 TR-60521 TR-60522 TR-60526 TR-60528 TR-60821 TR-60822 TR-60826 TR-60828 TR-61321 TR-61322 TR-61326 TR-61328 TR-61521 TR-61522 TR-61526 TR-61528 TR-61621 TR-61622 TR-61626 ** Page 35 35 35 35 38 38 38 38 35 35 35 35 38 38 38 38 35 35 35 35 38 38 38 38 35 35 35 35 38 38 38 38 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 36 40 40 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41 41 41 41 41 41 Product * TR-61628 TR-61721 TR-61722 TR-61726 TR-61728 TR-61821 TR-61822 TR-61826 TR-61828 TR-61921 TR-61922 TR-61926 TR-61928 TR-63121 TR-63122 TR-63126 TR-63128 TR-65121 TR-65122 TR-65126 TR-65128 TR-66121 TR-66122 TR-66126 TR-66128 TR-66521 TR-66522 TR-66526 TR-66528 TR-68129 TR-68169 VAKP012D VAKP024A VAKP024D VAKP048D VAKP110D VAKP120A VAP012D VAP024A VAP024D VAP048D VAP110D VAP120A VMKP012D VMKP024A VMKP024D VMKP048D VMKP110D VMKP120A VMP012D VMP024A VMP024D VMP048D VMP110D VMP120A VWKP012D VWKP024A VWKP024D VWKP048D VWKP110D VWKP120A VWP012D VWP024A VWP024D VWP048D VWP110D VWP120A Page 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 42 ** ** 26 26 26 26 26 26 26 26 26 26 26 26 25 25 25 25 25 25 25 25 25 25 25 25 28 28 28 28 28 28 28 28 28 28 28 28 Contact Macromatic for more information. PHASE MONITOR RELA YS RELAYS Product Summar y Summary Phase Monitor Relays provide protection against premature equipment failure caused by voltage faults on 3 Phase systems. All Macromatic Phase Monitor Relays are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. Phase Monitor Relays protect against single phasing regardless of any regenerative voltages. The Reference Guide below provides general information on the different versions of Phase Monitor Relays offered by Macromatic (see Product Selection on the following pages for further details): Series Mounting Style PCP Plug-in * PLP Plug-in * PAP Plug-in * PMP Plug-in * PMD Surface Phase Loss Phase Reversal ! ! ! ! ! ! ! ! ! Phase Unbalance Under Voltage Over Voltage Time Delay on Undervoltage Approvals * See Page 6 8 ! ! ! (adj.) ! (adj.) ! (adj.) ! (fixed) ! (fixed) 50ms fixed 10 0.1 - 20 sec. 12 0.1 - 20 sec. 14 * In addition to the above approvals, all Plug-in Products are also UL Listed when used with the appropriate Macromatic socket. Protection Typical Connections Depending on the unit selected, it will protect three phase equipment against: ! phase loss - total loss of one or more of the three phases. Also known as "single phasing." Typically caused by a blown fuse, broken wire, or worn contact. This condition would result in a motor drawing locked rotor current during start-up. In addition, a three phase motor will continue to run after losing a phase, resulting in possible motor burn-out. ! phase reversal - reversing any two of the three phases will cause a three phase motor to run in the opposite direction. This may cause damage to driven machinery or injury to personnel. The condition usually occurs as a result of mistakes made during routine maintenance or when modifications are made to the circuit. ! phase unbalance - unbalance of a three phase system occurs when single phase loads are connected such that one or two of the lines (phases) carry more or less of the load. This could cause motors to run at temperatures above published ratings. ! undervoltage - when voltage in all three lines of a three phase system drop simultaneously. ! overvoltage - when voltage in all three lines of a three phase system increase simultaneously. Line Side Monitoring With the relay connected before the motor starter, the motor can be started in the reverse direction. However, the motor is unprotected against phase failures between the relay and the motor. Load Side Monitoring With the relay connected directly to the motor, the total feed lines are monitored. This connection should not be used with reversing motors. 5 PHASE MONITOR RELA YS RELAYS Phase Reversal Only PC Series Plug-in ! Protects against phase reversal ! One version works on 208480V 3 Phase Systems ! LED indicates both normal and fault conditions ! Compact plug-in case utilizing industry-standard 8 pin octal socket ! 10A SPDT output contacts ! (with appropriate socket) The PC Series Phase Monitor Relays provide protection against phase reversal in a compact plug-in design. One version will work on any 3 phase system from 208V to 480V (a separate 120V-only version is also available). These devices are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. The relay is energized and the LED on when the sequence is correct. Any fault will de-energize the relay and turn off the LED. Re-energization is automatic upon correction of the fault condition. MOUNTING STYLE NOMINAL VOLTAGE 50/60 Hz UNDERVOLTAGE RANGE PRODUCT NUMBER WIRING/ SOCKET" " Plug-in 120V n/a PCP1 8 Pin Octal 70169-D 208-480V n/a PCP2 * DIAGRAM 23 * Requires a 600V-rated socket when used on system voltages greater than 300V. " See Page 16 for Sockets & Accessories 800-238-7474 www.macromatic.com whats-up@macromatic.com 6 PHASE MONITOR RELA YS RELAYS Phase Reversal Only PC Series Plug-in Application Data & Dimensions Application Data Phase Reversal: Unit trips if sequence of the three phases is anything other than A-B-C. Output Contacts: 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) Life: Full Load: 100,000 operations Response Times: Operate: 50ms Release: 50ms Load (Burden): 3VA Temperature: -28o to 65oC (-20o to 150oF) Transient Protection: 10,000 volts for 20 microseconds Mounting: Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16). Indicator LED: Red LED on when all conditions are normal, and off when a fault condition has occurred. Reset: Automatic upon correction of fault Approvals: When used with Macromatic socket 70169-D rated 600V File #E109466 File #E109466 Dimensions 2.4 (60) 2.9 (74) 3.0 (76) 1.7 (43) All Dimensions in Inches (Millimeters) 7 PHASE MONITOR RELA YS RELAYS Phase Loss & Phase Reversal PL Series Plug-in ! Protects against phase loss & phase reversal ! LED indicates both normal and fault conditions ! Compact plug-in case utilizing industry-standard 8 pin octal socket ! 10A SPDT output contacts ! (with appropriate socket) The PL Series Phase Monitor Relays provide protection against phase loss & phase reversal in a compact plug-in design. These devices are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. Phase Monitor Relays protect against single phasing regardless of any regenerative voltages. The relay is energized and the LED on when all three phases are present and in the correct sequence. Any fault will instantaneously de-energize the relay and turn off the LED. Re-energization is automatic upon correction of the fault condition. MOUNTING STYLE NOMINAL VOLTAGE 50/60 Hz UNDERVOLTAGE RANGE PRODUCT NUMBER WIRING/ " SOCKET" Plug-in 120V n/a PLP120 8 Pin Octal 70169-D 208V n/a PLP208 240V n/a PLP240 400V n/a PLP400 * 480V n/a PLP480 * DIAGRAM 23 * Requires a 600V-rated socket when used on system voltages greater than 300V. " See Page 16 for Sockets & Accessories 800-238-7474 www.macromatic.com whats-up@macromatic.com 8 PHASE MONITOR RELA YS RELAYS Phase Loss & Phase Reversal PL Series Plug-in Application Data & Dimensions Application Data Phase Loss: Unit trips on loss of any Phase A, B or C Phase Reversal: Unit trips if sequence of the three phases is anything other than A-B-C. Output Contacts: 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) Life: Full Load: 100,000 operations Response Times: Operate: 50ms Release: 50ms Load (Burden): 3VA Temperature: -28o to 65oC (-20o to 150oF) Transient Protection: 10,000 volts for 20 microseconds Mounting: Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16). Indicator LED: Red LED on when all conditions are normal, and off when a fault condition has occurred. Reset: Automatic upon correction of fault Approvals: When used with Macromatic socket 70169-D rated 600V File #E109466 File #E109466 Dimensions 2.4 (60) 2.9 (74) 3.0 (76) 1.7 (43) All Dimensions in Inches (Millimeters) 9 PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal & Under voltage Undervoltage PA Series Plug-in ! Protects against phase loss, phase reversal & undervoltage ! Undervoltage setting is adjustable from 75-95% of nominal ! LED indicates both normal and fault conditions ! Compact plug-in case utilizing industry-standard 8 pin octal socket ! 10A SPDT output contacts ! (with appropriate socket) The PA Series Phase Monitor Relays provide protection against phase loss, phase reversal & undervoltage in a compact plug-in design. These devices are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. Phase Monitor Relays protect against single phasing regardless of any regenerative voltages. The relay is energized and the LED on when all three phase are present in the correct sequence at a voltage level above the undervoltage setting. The undervoltage drop-out can be set at 75-95% of operating voltage. Any fault will instantaneously de-energize the relay and turn off the LED. Re-energization is automatic upon correction of the fault condition. MOUNTING STYLE NOMINAL VOLTAGE 60 Hz UNDERVOLTAGE RANGE PRODUCT NUMBER WIRING/ SOCKET" " Plug-in 120V 90-115V PAP120 8 Pin Octal 70169-D 208V 156-198V PAP208 240V 180-230V PAP240 400V 300-380V PAP400 * 480V 360-460V PAP480 * DIAGRAM 23 * Requires a 600V-rated socket when used on system voltages greater than 300V. " See Page 16 for Sockets & Accessories 800-238-7474 www.macromatic.com whats-up@macromatic.com 10 PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal & Under voltage Undervoltage PA Series Plug-in Application Data & Dimensions Application Data Phase Loss: Unit trips on loss of any Phase A, B or C Phase Reversal: Unit trips if sequence of the three phases is anything other than A-B-C. Undervoltage: Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set point. Output Contacts: 10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.) Life: Full Load: 100,000 operations Response Times: Operate: 50ms Release: 50ms Load (Burden): 3VA Temperature: -28o to 65oC (-20o to 150oF) Transient Protection: 10,000 volts for 20 microseconds Mounting: Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16). Indicator LED: Red LED on when all conditions are normal, and off when a fault condition has occurred. Reset: Automatic upon correction of fault Approvals: When used with Macromatic socket 70169-D rated 600V File #E109466 File #E109466 Dimensions 2.4 (60) 2.9 (74) 3.5 (89) 1.7 (43) All Dimensions in Inches (Millimeters) 11 PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over V oltage Voltage PMP Series Plug-in ! Universal voltage range of 208-480V on PMPU provides the flexibility to cover a variety of applications ! Protects against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage ! Variety of user-selectable and adjustable settings for the ultimate in three-phase protection ! Automatic or Manual Reset ! Multi-Color LED indicates normal condition and defines fault to simplify troubleshooting ! Compact plug-in case utilizing industry-standard 8 pin octal socket ! 10A SPDT output contacts The PMP Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMPU is a universal voltage product that works on any three-phase system voltage from 208-480V (a separate 120V version is available). These devices are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. PMP Series products protect against unbalanced voltages or single phasing regardless of any regenerative voltages. The relay is energized when the phase sequence and all voltages are correct. Any one of five fault conditions will de-energize the relay. As standard, re-energization is automatic upon correction of the fault condition. Manual reset is available if a momentary N.C. switch is wired to the appropriate terminals. A multi-color LED indicates normal condition and also provides specific fault indication to simplify troubleshooting. The PMP Series offers a variety of user-adjustable settings. The percent phase unbalance is adjustable from 2-10%, and also has a “Disable” setting for those applications where poor voltage conditions could cause nuisance tripping. The undervoltage drop-out can be set at 80-95% of operating voltage (overvoltage setting is fixed at 110% of nominal). The adjustable time delay drop-out on undervoltage (0.1-20 seconds) eliminates nuisance tripping caused by momentary voltage fluctuations. There is also an adjustable time delay (1-300 seconds) on both power up and restart after a fault has been cleared. ! MOUNTING STYLE OPERATING VOLTAGE 50/60 Hz PRODUCT NUMBER Plug-in 120V PMP120 208-480V PMPU * (with appropriate socket) WIRING/SOCKET " 8 Pin Octal 70169-D DIAGRAM 104 * Requires a 600V-rated socket when used on system voltages greater than 300V. " See Page 16 for Sockets & Accessories 800-238-7474 www.macromatic.com whats-up@macromatic.com 12 PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over V oltage Voltage PMP Series Plug-in Application Data & Dimensions Application Data Phase Loss: Unit trips on loss of any Phase A, B or C. Hysteresis: 2 - 3% Load (Burden): Less than 3VA Phase Reversal: Unit trips if rotation (sequence) of the three phases is anything other than A-B-C. Undervoltage: Adjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out. Overvoltage: Fixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out. Temperature: -28o to 65oC (-20o to 150oF) Mounting: Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic Product Number 70169-D--see Page 16). Indicator LED: LED Status Indicator Green Steady Normal / Relay ON Green Flashing Power Up / Restart Delay Phase Unbalance: Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a “Disable” setting adjustment that will turn off the Phase Unbalance Protection if nuisance tripping is a problem. Red Steady Unbalance Red Flashing Undervoltage / Overvoltage Amber Steady Reversal Amber Flashing Output Contacts: SPDT: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 120/240V AC Green / Red Alternating Loss Undervoltage / Overvoltage Trip Pending Nominal Voltage Set Error Red / Amber Alternating * * Applies to 208-480V units only. Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Response Times: Power Up & Restart After Fault: Drop-out Due to Fault: Phase Loss & Reversal Phase Unbalance Undervoltage Overvoltage 1 - 300 seconds adjustable 100ms fixed 2 seconds fixed 0.1 - 20 seconds adjustable Fixed Time Based on Inverse Time Curve Reset: As standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available. Approvals: Low Voltage & EMC Directives EN60947-1, EN60947-5-1 File #E109466 When used with Macromatic socket 70169-D rated 600V File #E109466 Dimensions 2.4 (60) All Dimensions in Inches (Millimeters) 2.9 (74) 1.7 (43) 3.0 (77) 13 PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over V oltage Voltage PMD Series Surface-Mount ! Universal voltage range of 208-480V on PMDU provides the flexibility to cover a variety of applications ! Protects against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage ! Variety of user-selectable and adjustable settings for the ultimate in three-phase protection ! Automatic or Manual Reset ! Multi-Color LED indicates normal condition and defines fault to simplify troubleshooting ! 45mm DIN-style surfacemount case ! 10A SPDT & SPNC output contacts The PMD Series Phase Monitor Relays utilize a microprocessor-based design to provide protection against phase loss, phase reversal, phase unbalance, undervoltage and overvoltage. The PMDU is a universal voltage product that works on any three-phase system voltage from 208-480V (separate 120V & 600V versions are available). These devices are designed to be compatible with most Wye or Delta systems. In Wye systems, a connection to a neutral is not required. PMD Series products protect against unbalanced voltages or single phasing regardless of any regenerative voltages. The relay is energized when the phase sequence and all voltages are correct. Any one of five fault conditions will de-energize the relay. As standard, re-energization is automatic upon correction of the fault condition. Manual reset is available if a momentary N.C. switch is wired to the appropriate terminals. A multi-color LED indicates normal condition and also provides specific fault indication to simplify troubleshooting. The PMD Series offers a variety of user-adjustable settings. The percent phase unbalance is adjustable from 2-10%, and also has a “Disable” setting for those applications where poor voltage conditions could cause nuisance tripping. The undervoltage drop-out can be set at 80-95% of operating voltage (overvoltage setting is fixed at 110% of nominal). The adjustable time delay drop-out on undervoltage (0.1-20 seconds) eliminates nuisance tripping caused by momentary voltage fluctuations. There is also an adjustable time delay (1-300 seconds) on both power up and restart after a fault has been cleared. ! MOUNTING STYLE OPERATING VOLTAGE 50/60 Hz PRODUCT NUMBER ! Surface-Mount 120V PMD120 208-480V 600V WIRING " PMDU PMD600 DIAGRAM 105 ! To order PMD units with a second N.O. contact instead of the N.C. (terminals 21-22), 800-238-7474 www.macromatic.com whats-up@macromatic.com 14 add a suffix “-A1” to the Product Number, i.e., PMDU-A1. To order PMD units with DPDT output contacts instead of one SPDT and one SPNC, but with no manual reset feature, add a suffix “-A2” to the Product Number, i.e., PMDU-A2. " See Page 16 for Accessories PHASE MONITOR RELA YS RELAYS Phase Loss, Phase Reversal, Phase Unbalance, and Under/Over V oltage Voltage PMD Series Surface-Mount Application Data & Dimensions Application Data Phase Loss: Unit trips on loss of any Phase A, B or C. Hysteresis: 2 - 3% Load (burden): Less than 3VA Phase Reversal: Unit trips if rotation (sequence) of the three phases is anything other than A-B-C. Undervoltage: Adjustable from 80-95% of nominal voltage. Unit trips when the average of all three lines is less than the adjusted set point for a period longer than the adjustable time delay drop-out. Overvoltage: Fixed at 110% of nominal voltage. Unit trips when the average of all three lines is greater than the fixed set point for a period longer than the time delay drop-out. Phase Unbalance: Adjustable from 2 - 10% unbalance. Unit trips when any one of the three lines deviates from the average of all three lines by more than the adjusted set point . There is also a “Disable” setting adjustment that will turn off the Phase Unbalance Protection if nuisance tripping is a problem. Temperature: -28o to 65oC (-20o to 150oF) Mounting: Does not require a socket. Can either be mounted directly on 35mm DIN track with no additional parts or to a back-panel with two screws. Indicator LED: LED Status Green Steady Normal / Relay ON Green Flashing Power Up / Restart Delay Red Steady Unbalance Red Flashing Undervoltage / Overvoltage Amber Steady Reversal Amber Flashing Loss Undervoltage / Overvoltage Trip Pending Nominal Voltage Set Error Output Contacts: SPDT & SPNC N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC Green / Red Alternating Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations * Applies to 208-480V units only. Response Times: Power Up & Restart After Fault: Drop-out Due to Fault: Phase Loss & Reversal Phase Unbalance Undervoltage Overvoltage 1 - 300 seconds adjustable 100ms fixed 2 seconds fixed 0.1 - 20 seconds adjustable Fixed Time Based on Inverse Time Curve Indicator Red / Amber Alternating * Reset: As standard, reset is automatic upon correction of fault. When a momentary-contact N.C. switch is wired across the Manual Reset terminals (5 & 6), the unit switches to manual reset mode and remote manual reset is available. Approvals: Low Voltage & EMC Directives EN60947-1, EN60947-5-1 File #E109466 Dimensions TWO 0.2 (5) MOUNTING HOLES 2.7 2.4 (70) (60) All Dimensions in Inches (Millimeters) 1.4 (35) 1.8 (45) 4.3 (110) 4.4 (112) 15 SOCKETS & ACCESSORIES Sockets Product Number 70169-D * Product Number 70170-D Product Number 70171-D Description 8 Pin Octal 11 Pin Octal 11 Pin Spade (Blade) Ratings 10A @ 600V * 10A @ 300V 10A @ 300V Mounting 35MM DIN Rail / Direct Panel 35MM DIN Rail / Direct Panel 35MM DIN Rail / Direct Panel Wire/ Terminations 1 or 2 #12-22 / Pressure Wire Clamps 1 or 2 #12-22 / Pressure Wire Clamps 1 or 2 #12-22 / Pressure Wire Clamps Approvals Dimensions All Dimensions in Inches (Millimeters) * Plug-in Three-Phase Monitor Relays require a 600V-rated socket when used on system voltages greater than 300V. Other Accessories Hold Down Spring Product Number 70166 35mm DIN Mounting Track (3 FT. Section) Product Number 70100 End Clamp Product Number 70200 16 CURRENT MONITOR RELA YS RELAYS Product Summar y Summary Current Monitor Relays monitor AC single phase currents for over or under current conditions. A separate 24 or 120VAC input (supply) voltage is required to power these units. Three current ranges are available: 0.1 – 1A; 0.5 – 5A; and 1 – 10A. An external current transformer may be used to extend the range of these products (see Typical Installations below). All versions are available in a compact plug-in case utilizing industry-standard 8 or 11 pin octal sockets. The Reference Guide below provides general information on the different versions of Current Monitor Relays offered by Macromatic (see Product Selection on the following pages for further details): Pick-up Type Series Standard CMP (Fixed time delay on both pick-up and dropout current settings) CMKP Overcurrent COP (Adjustable time delay on pick-up and fixed time delay on drop-out current settings) COKP Drop-out Setting Time Delay Adjustable (Across Monitored Range) Fixed 100ms * Adjustable (Across Monitored Range) 0.1-10 sec Adjustable Fixed (+5% Drop-out) Fixed 100ms * Setting Time Delay Fixed (-5% Pick-up) Fixed 100ms * Adjustable (50-95% Pick-up) Fixed 100ms * Fixed (-5% Pick-up) Fixed 100ms * Adjustable (50-95% Pick-up) Fixed 100ms * Adjustable (Across Monitored Range) 0.1-10 sec Adjustable See Page 18 20 Undercurrent (Fixed time delay on pick-up and adjustable time delay on drop-out current settings) CUP 22 *Fixed time delay eliminates nuisance tripping due to short current surges or drops. Approvals All Macromatic plug-in Current Monitor Relays are UL Component Recognized. We are also in the process of obtaining UL Listing when used with the appropriate Macromatic socket--check with Macromatic for updated information. Typical Installations Without External CT With External CT 17 CURRENT MONITOR RELA YS RELAYS AC Plug-in CM Series Standard ! Monitors AC single phase currents ! Three separate current monitoring ranges covering 0.1 - 10 amperes ! External CT can be used to extend ranges ! Adjustable Pick-up Setting with either Fixed or Adjustable Drop-out Setting ! LED indicates output relay status ! Choice of compact 8 Pin SPDT or 11 Pin DPDT plugin case ! 10A output contacts NEW PRODUCT The CM Series is used to detect either an overcurrent or undercurrent condition. The pickup current setting is user-adjustable within one of three ranges as shown in the Product Selection Table below. An external current transformer can be used to extend the range beyond 10 amperes. Choose between a fixed drop-out current setting at 95% of the selected pick-up setting or an adjustable drop-out setting of 5095% of the selected pick-up setting. The relay will energize when the monitored AC current is above the pick-up setting, and will de-energize when the monitored AC current is below the drop-out setting. The time delay on both pick-up and drop-out is fixed at 100ms (for products with adjustable time delay on pick-up, see page 20; for adjustable time delay on drop-out, see page 22). SPDT 8 Pin Plug-in ! (with appropriate socketListing Pending) Pick-up Setting Adjustable Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A CMP01A68 CMP05A68 CMP10A68 CMP01A62 CMP05A62 CMP10A62 8 Pin 70169-D 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A CMKP01A68 CMKP05A68 CMKP10A68 CMKP01A62 CMKP05A62 CMKP10A62 Diagram 21 (At 95% of Pick-Up) 120V AC Adjustable Adjustable 24V AC (From 50-95% of Pick-Up) 120V AC DPDT 11 Pin Plug-in Pick-up Setting Adjustable Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A CMP01A28 CMP05A28 CMP10A28 CMP01A22 CMP05A22 CMP10A22 11 Pin 70170-D 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A CMKP01A28 CMKP05A28 CMKP10A28 CMKP01A22 CMKP05A22 CMKP10A22 (At 95% of Pick-Up) 120V AC Adjustable Adjustable 24V AC (From 50-95% of Pick-Up) 800-238-7474 120V AC www.macromatic.com whats-up@macromatic.com 18 Sockets & Accessories−Page 16 Dimensions−Page 19 Application Data−Page 19 Diagram 22 CURRENT MONITOR RELA YS RELAYS AC Plug-in CM Series Standard Application Data & Dimensions Application Data Input Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. Load (Burden): Less than 5VA Current Settings: Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (CMP Series); or Adjustable from 50-95% of pick-up setting (CMKP Series) Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Indicator LED: Green when Input Voltage is applied; Red when Relay is energized Reset: Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. Temperature: -28o to 55o C (-20o to 131o F) Mounting: Requires an 8 or 11 pin octal socket--see page 16. Response Times: Pick-up: 100ms Drop-out: 100ms Approvals: Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) File #E109466 with appropriate Macromatic socket-Listing Pending File #E109466 Dimensions 2.4 (60) CMKP Only 2.9 (74) 1.7 (43) 3.5 (89) All dimensions are inches (millimeters) 19 CURRENT MONITOR RELA YS RELAYS AC Plug-in CO Series Overcurrent ! Monitors AC single phase currents for overcurrent conditions ! Three separate current monitoring ranges covering 0.1 - 10 amperes ! External CT can be used to extend ranges ! Adjustable Pick-up Setting with either Fixed or Adjustable Drop-out Setting ! Adjustable time delay of 0.110 seconds on pick-up ! LED indicates output relay status ! Choice of compact 8 Pin SPDT or 11 Pin DPDT plugin case ! 10A output contacts NEW PRODUCT The CO Series is used to detect an overcurrent condition. The pick-up current setting is user-adjustable within one of three ranges as shown in the Product Selection Table below. An external current transformer can be used to extend the range beyond 10 amperes. Choose between a fixed drop-out current setting at 95% of the selected pick-up setting or an adjustable drop-out setting of 5095% of the selected pick-up setting. The relay will energize when the monitored AC current is above the pick-up setting for a period longer than the adjustable time delay of 0.1-10 seconds. This delay prevents nuisance tripping caused by inrush currents. It will de-energize when the monitored AC current is below the drop-out setting. 8 Pin SPDT Plug-in Pick-up Setting Adjustable Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A COP01A68 COP05A68 COP10A68 COP01A62 COP05A62 COP10A62 8 Pin 70169-D 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A COKP01A68 COKP05A68 COKP10A68 COKP01A62 COKP05A62 COKP10A62 Diagram 21 (At 95% of ! Pick-Up) 120V AC (with appropriate socketListing Pending) Adjustable Adjustable 24V AC (From 50-95% of Pick-Up) 120V AC 11 Pin DPDT Plug-in Pick-up Setting Adjustable Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A COP01A28 COP05A28 COP10A28 COP01A22 COP05A22 COP10A22 11 Pin 70170-D 0.1 - 1A 0.5 - 5A 1 - 10A 0.1 - 1A 0.5 - 5A 1 - 10A COKP01A28 COKP05A28 COKP10A28 COKP01A22 COKP05A22 COKP10A22 (At 95% of Pick-Up) 120VAC Adjustable Adjustable 24V AC (From 50-95% of Pick-Up) 800-238-7474 www.macromatic.com whats-up@macromatic.com 20 120V AC Sockets & Accessories−Page 16 Dimensions−Page 21 Application Data−Page 21 Diagram 22 CURRENT MONITOR RELA YS RELAYS AC Plug-in CO Series Overcurrent Application Data & Dimensions Application Data Input Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. Load (Burden): Less than 5VA Current Settings: Pick-up: Adjustable throughout current range monitored Drop-out: Fixed at 95% of pick-up setting (COP Series); or Adjustable from 50-95% of pick-up setting (COKP Series) Temperature: -28o to 55o C (-20o to 131o F) Response Times: Pick-up: Adjustable 0.1-10 seconds Drop-out: Fixed 100ms Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Indicator LED: Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. Reset: Automatic. Contact Macromatic for information on a product with a latching function--the relay remains energized even after the current drops below the dropout setting until a remote N.C. button is opened. Mounting: Requires an 8 or 11 pin octal socket--see page 16. Approvals: File #E109466 with appropriate Macromatic socket-Listing Pending File #E109466 Dimensions 2.4 (60) COKP Only 2.9 (74) 1.7 (43) 3.5 (89) All dimensions are inches (millimeters) 21 CURRENT MONITOR RELA YS RELAYS AC Plug-in CU Series Undercurrent ! Monitors AC single phase currents for undercurrent conditions ! Three separate current monitoring ranges covering 0.1 - 10 amperes ! External CT can be used to extend ranges ! Adjustable Drop-out Setting with Fixed Pick-up Setting ! Adjustable time delay of 0.110 seconds on drop-out ! LED indicates output relay status ! Choice of compact 8 Pin SPDT or 11 Pin DPDT plugin case ! 10A output contacts ! NEW PRODUCT The CU Series is used to detect an undercurrent condition. The drop-out current setting is user-adjustable within one of three ranges as shown in the Product Selection Table below. An external current transformer can be used to extend the range beyond 10 amperes. The pick-up current setting is fixed at +5% of the selected drop-out setting. The relay will energize when the monitored AC current is above the pick-up setting. It will de-energize when the monitored AC current is below the drop-out setting for a period longer than the adjustable time delay of 0.1-10 seconds. This delay prevents nuisance tripping caused by momentary line dips. The relay will energize when the current rises 5% above the drop-out setting. 8 Pin SPDT Plug-in Pick-up Setting Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed Adjustable 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A CUP01A68 CUP05A68 CUP10A68 8 Pin 70169-D 120V AC 0.1 - 1A 0.5 - 5A 1 - 10A CUP01A62 CUP05A62 CUP10A62 (At +5% of (with appropriate socketListing Pending) Drop-Out) Diagram 21 11 Pin DPDT Plug-in Pick-up Setting Drop-Out Setting Input Voltage Current Range Monitored Product Number Wiring/ Socket Fixed Adjustable 24V AC 0.1 - 1A 0.5 - 5A 1 - 10A CUP01A28 CUP05A28 CUP10A28 11 Pin 70170-D 120V AC 0.1 - 1A 0.5 - 5A 1 - 10A CUP01A22 CUP05A22 CUP10A22 (At +5% of Drop-Out) 800-238-7474 Diagram 22 www.macromatic.com whats-up@macromatic.com 22 Sockets & Accessories−Page 16 Dimensions−Page 23 Application Data−Page 23 CURRENT MONITOR RELA YS RELAYS AC Plug-in CU Series Undercurrent Application Data & Dimensions Application Data Input Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. Load (Burden): Less than 5VA Current Settings: Pick-up: Fixed at 5% above adjustable drop-out setting Drop-out: Adjustable throughout current range monitored Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Indicator LED: Green when Input Voltage is applied; Red Flashing when in time delay; and Red Steady when Relay is energized. Reset: Automatic Temperature: -28o to 55o C (-20o to 131o F) Mounting: Requires an 8 or 11 pin octal socket--see page 16. Response Times: Pick-up: Fixed 100ms Drop-out: Adjustable 0.1-10 seconds Approvals: Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) File #E109466 with appropriate Macromatic socket-Listing Pending File #E109466 Dimensions 2.4 (60) 2.9 (74) 1.7 (43) 3.5 (89) All dimensions are inches (millimeters) 23 VOL TAGE MONITOR RELA YS VOLT RELAYS Product Summar y Summary Voltage Monitor Relays monitor either AC single phase (50-60Hz) or DC voltages to protect equipment against voltage fault conditions. No separate supply (input) voltage is required on any Macromatic Voltage Monitor Relays. All versions are available in a compact plug-in case utilizing an 8 pin octal socket. Macromatic offers two styles of Voltage Monitor Relays: ! Over/Under Voltage Relays--provides protection to equipment where either an over or under voltage condition is potentially damaging. When used as an under voltage relay, they provide protection to equipment that is required to operate above a minimum voltage. When used as over voltage relays, they protection equipment against excessive voltage conditions. Over/Under Voltage Relays are designed to operate when the operating voltage reaches a preset value and drop-out when the operating voltage drops to a level below the preset value. ! Voltage Band Relays--provides protection to equipment that is required to operate within an upper & lower voltage limit. As long as the operating voltage remains within an OVER & UNDER voltage range, the internal relay stays energized. If the operating voltage falls outside this range, the relay will drop-out. These products are summarized below: Over/Undervoltage Relays Pick-up Voltage Drop-out Voltage Time Delay Drop-Out VMP Adjustable 85115% Nominal Fixed at 95% of Pick-Up Fixed 500ms * 25 VMKP Adjustable 85115% Nominal Adjustable 7595% of Pick-up Fixed 500ms * 25 VAP Adjustable 85115% Nominal Fixed at 95% of Pick-Up Adjustable 0.5-10 seconds 26 VAKP Adjustable 85115% Nominal Adjustable 7595% of Pick-up Adjustable 0.5-10 seconds 26 Series Function Chart Page Voltage Band Relays Over Voltage Voltage Under Voltage Voltage Time Delay Drop-Out VWP Adjustable 100-125% of Nominal Adjustable 75-100% of Nominal Fixed 500ms * 28 VWKP Adjustable 100-125% of Nominal Adjustable 75-100% of Nominal Adjustable 0.5-10 seconds 28 Series Function Chart Page *Fixed time delay eliminates nuisance tripping due to short voltage surges or drops. Approvals All Macromatic plug-in Voltage Monitor Relays are UL Component Recognized. We are also in the process of obtaining UL Listing when used with the appropriate Macromatic socket--check with Macromatic for updated information. 24 VOL TAGE MONITOR RELA YS VOLT RELAYS VM Series Over/Under voltage Over/Undervoltage Fixed Time Delay on Drop-Out NEW PRODUCT Over/Under Voltage Relays provide protection to equipment where either an over or under voltage condition is potentially damaging. They are designed to operate when the operating voltage reaches a preset value and drop-out when the operating voltage drops to a level below the preset value. The pick-up voltage setting is useradjustable from 85-115% of the nominal voltage rating. As standard, the VMP Series has a drop-out voltage setting fixed at 95% of the pick-up voltage setting. An adjustable drop-out setting of 75-95% of the pick-up setting is available on the VMKP Series. The relay energizes when the monitored voltage is above the pick-up setting. The relay de-energizes when the monitored voltage is below the drop-out setting for a period longer than the drop-out time delay (T), which is a fixed 500ms for VM Series products. An adjustable time delay on drop-out of 0.5-10 seconds is available (see Page 26). ! Monitors AC single phase and DC voltages ! Wide range of user-adjustable pick-up and drop-out settings ! Fixed time delay on drop-out of 500ms ! LED indicates output relay status ! Compact plug-in case utilizing industry standard 8 pin octal socket ! 10A DPDT output contacts ! (with appropriate socketListing Pending) Adjustable Pick-Up, Fixed Drop-Out Settings * Time Delay on Drop-out Fixed at 500ms NOMINAL VOLTAGE# # * PICK-UP DROP-OUT VOLTAGE RANGE VOLTAGE RANGE* PRODUCT NUMBER WIRING/ SOCKET 24V AC 120V AC 21-27V AC 102-138V AC 20-26V AC 99-134V AC VMP024A VMP120A 8 Pin Octal 70169-D 12V DC 24V DC 48V DC 110V DC 10-14V DC 21-27V DC 41-55V DC 94-126V DC 9-13V DC 20-26V DC 39-53V DC 91-122V DC VMP012D VMP024D VMP048D VMP110D DIAGRAM 20 Drop-out Voltage is fixed at 95% of the adjusted Pick-up Setting. Adjustable Pick-Up & Drop-Out Settings ** Time Delay on Drop-out Fixed at 500ms NOMINAL PICK-UP DROP-OUT VOLTAGE# # VOLTAGE RANGE VOLTAGE RANGE 24V AC 120V AC 21-27V AC 102-138V AC 16-26V AC 77-131V AC PRODUCT NUMBER" " WIRING/ SOCKET VMKP024A VMKP120A 8 Pin Octal 70169-D 12V DC 10-14V DC 8-13V DC VMKP012D 24V DC 21-27V DC 16-26V DC VMKP024D 48V DC 41-55V DC 32-52V DC VMKP048D 110V DC 94-126V DC 71-119V DC VMKP110D DIAGRAM 20 ** Drop-out Voltage is adjustable from 75-95% of the adjusted Pick-up Setting. # Contact Macromatic for information on units above 120V. " These products replace those products previously sold with a suffix “-G”--contact Macromatic for more information. Sockets & Accessories−Page 16 800-238-7474 www.macromatic.com whats-up@macromatic.com Application Data/Dimensions−Page 27 25 VOL TAGE MONITOR RELA YS VOLT RELAYS VA Series Over/Under voltage Over/Undervoltage NEW PRODUCT Adjustable Time Delay on Drop-Out ! Monitors AC single phase and DC voltages ! Wide range of user-adjustable pick-up and drop-out settings ! Adjustable time delay on drop-out of 0.1 - 10 seconds ! LED indicates output relay status ! Compact plug-in case utilizing industry standard 8 pin octal socket ! 10A DPDT output contacts ! (with appropriate socketListing Pending) Over/Under Voltage Relays provide protection to equipment where an over or under voltage condition is potentially damaging. They are designed to operate when the operating voltage reaches a preset value and drop-out when the operating voltage drops to a level below the preset value. The pick-up voltage setting is useradjustable from 85-115% of the nominal voltage rating. As standard, the VAP Series has a dropout voltage setting fixed at 95% of the pick-up voltage setting. An adjustable drop-out setting of 7595% of the pick-up setting is available on the VAKP Series. The relay energizes when the monitored voltage is above the pick-up setting. The relay de-energizes when the monitored voltage is below the drop-out setting for a period longer than the drop-out time delay (T), which is adjustable from 0.5-10 seconds for VA Series products. A time delay on drop-out fixed at 500ms is available (see Page 25). Adjustable Pick-Up, Fixed Drop-Out Settings * Adjustable Time Delay on Drop-out from 0.5 - 10 Seconds NOMINAL VOLTAGE# # 24V AC 120V AC PICK-UP DROP-OUT VOLTAGE RANGE VOLTAGE RANGE* 21-27V AC 102-138V AC 20-26V AC 99-134V AC PRODUCT NUMBER WIRING/ SOCKET VAP024A VAP120A 8 Pin Octal 70169-D 12V DC 10-14V DC 9-13V DC VAP012D 24V DC 21-27V DC 20-26V DC VAP024D 48V DC 41-55V DC 39-53V DC VAP048D 110V DC 94-126V DC 91-122V DC VAP110D * Drop-out Voltage is fixed at 95% of the adjusted Pick-up Setting. DIAGRAM 20 Adjustable Pick-Up & Drop-Out Settings ** Adjustable Time Delay on Drop-out from 0.5 - 10 Seconds NOMINAL PICK-UP DROP-OUT VOLTAGE# # VOLTAGE RANGE VOLTAGE RANGE 24V AC 120V AC 800-238-7474 www.macromatic.com whats-up@macromatic.com 26 21-27V AC 102-138V AC 16-26V AC 77-131V AC PRODUCT NUMBER WIRING/ SOCKET VAKP024A VAKP120A 8 Pin Octal 70169-D 12V DC 10-14V DC 8-13V DC VAKP012D 24V DC 21-27V DC 16-26V DC VAKP024D 48V DC 41-55V DC 32-52V DC VAKP048D 110V DC 94-126V DC 71-119V DC VAKP110D DIAGRAM 20 ** Drop-out Voltage is adjustable from 75-95% of the adjusted Pick-up Setting. # Contact Macromatic for information on units above 120V. Sockets & Accessories−Page 16 Application Data/Dimensions−Page 27 VOL TAGE MONITOR RELA YS VOLT RELAYS VM & V A Series Over/Under voltage VA Over/Undervoltage Application Data & Dimensions Operating Modes These relays can be used as either overvoltage or undervoltage relays, depending on the output contact used: Undervoltage Relay Provides protection to equipment that is required to operate above a certain minimum voltage. Uses a normally open contact (N.O.). As long as the monitored voltage is above the minimum value required (Pick-Up Setting), the relay will energize and the N.O. contact closes, turning on the load. If the voltage drops below the Drop-out Setting (the minimum voltage required minus the hysteresis), the relay will de-energize and the N.O. contact will re-open, turning off the load. Overvoltage Relay Provides protection to equipment that cannot handle excess voltages. Uses a normally closed contact (N.C.). As long as the monitored voltage remains below the maximum voltage the equipment can withstand (Pick-Up Setting), the relay remains deenergized and the N.C. contact remains closed, keeping the load energized. If the operating voltage increases beyond the maximum rating of the equipment, the relay energizes and the N.C. contact opens, turning off the load. When the voltage falls below the Drop-Out Setting (hysteresis), the relay de-energizes and the N.C. contact re-closes, turning on the load. Application Data Voltage Tolerance: +25%/-50% of nominal voltage; AC voltages are 50-60Hz; No supply (input) voltage is required. Load (Burden): Less than 3VA Voltage Settings: Pick-up: Adjustable from 85-115% of nominal voltage Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series) Adjustable from 75-95% of pick-up setting (VMKP & VAKP Series) Temperature: -28o to 55o C (-20o to 131o F) Response Times: Operate: 500ms Release: Fixed 500 ms (VMP & VMKP Series) Adjustable 0.5 - 10 Seconds (VAP & VAKP Series) Indicator LED: Red Steady when Relay is energized; Green when Relay is Off; and Red Flashing when in time delay. Transient Protection: 10,000 volts for 20 microseconds Reset: Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. Approvals: Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) File #E109466 Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations with appropriate Macromatic socket-Listing Pending File #E109466 Dimensions 2.4 (60) VMKP & VAKP Only 2.9 (74) 3.5 (89) 1.7 (43) All Dimensions in Inches (Millimeters) 27 VOL TAGE MONITOR RELA YS VOLT RELAYS VW Series V oltage Band Voltage NEW PRODUCT ! Monitors AC single phase and DC voltages ! Provides voltage band (window) protection ! Wide range of user-adjustable Over Voltage and Under Voltage settings ! Fixed or adjustable time delay on drop-out ! LED indicates output relay status ! Compact plug-in case utilizing industry standard 8 pin octal socket ! 10A DPDT output contacts ! Voltage Band Relays provide protection to equipment that is required to operate within an upper & lower voltage limit. As long as the operating voltage remains within an OVER & UNDER voltage range, the internal relay stays energized. If the operating voltage falls outside this range, the relay will drop-out. When nominal operating voltage is applied, the internal relay will energize (Pick-up). If the operating voltage falls outside the preset OVER trip point (adjustable 100-125% of nominal) or UNDER trip point (adjustable 75-100% of nominal) for a period longer than the drop-out time delay (T), the relay will de-energize (Drop-out). When the voltage returns to normal (within the preset OVER & UNDER trip points), the unit automatically resets and the relay energizes. Choose between a unit with fixed drop-out time of 500ms or one with an adjustable 0.5-10 second drop-out time. (with appropriate socketListing Pending) Fixed Drop-Out Time Delay (500ms) NOMINAL VOLTAGE# # OVER VOLTAGE RANGE UNDER VOLTAGE RANGE PRODUCT NUMBER WIRING/ SOCKET 24V AC 120V AC 24-30V AC 120-150V AC 18-24V AC 90-120V AC VWP024A VWP120A 8 Pin Octal 70169-D 12V DC 24V DC 48V DC 110V DC 12-15V DC 24-30V DC 48-60V DC 110-137V DC 9-12V DC 18-24V DC 36-48V DC 83-110V DC VWP012D VWP024D VWP048D VWP110D DIAGRAM 20 Adjustable Drop-Out Time Delay 0.5 - 10 Seconds 800-238-7474 www.macromatic.com whats-up@macromatic.com NOMINAL VOLTAGE# # OVER VOLTAGE RANGE UNDER VOLTAGE RANGE PRODUCT NUMBER WIRING/ SOCKET 24V AC 120V AC 24-30V AC 120-150V AC 18-24V AC 90-120V AC VWKP024A VWKP120A 8 Pin Octal 70169-D 12V DC 12-15V DC 24V DC 24-30V DC 48V DC 48-60V DC 110V DC 110-137V DC # Contact Macromatic for information Sockets & Accessories-Page 16 28 9-12V DC VWKP012D 18-24V DC VWKP024D 36-48V DC VWKP048D 83-110V DC VWKP110D on units above 120V. DIAGRAM 20 Application Data/Dimensions-Page 29 VOL TAGE MONITOR RELA YS VOLT RELAYS VW Series V oltage Band Voltage Application Data & Dimensions Application Data Voltage Tolerance: +25%/-50% of nominal voltage; AC voltages are 50-60Hz; No supply (input) voltage is required. Load (Burden): Less than 3VA Response Times: Operate: 500ms Release: Fixed 500 ms (VWP Series) Adjustable 0.5 -10 Seconds (VWKP Series) Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.), 1/3HP @ 240V AC (N.C.) Voltage Settings: Over Voltage: 100-125% of Nominal Voltage Under Voltage: 75-100% of Nominal Voltage Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Temperature: -28o to 55o C (-20o to 131o F) Indicator LED: Red Steady when Relay is energized; Green when Relay is Off; and Red Flashing when in time delay. Reset: Automatic. Contact Macromatic for information on how to order a unit with Manual Reset. Transient Protection: 10,000 volts for 20 microseconds Approvals: File #E109466 with appropriate Macromatic socket-Listing Pending File #E109466 Dimensions 2.4 (60) VWKP Only 2.9 (74) 1.7 (43) 3.5 (89) All Dimensions in Inches (Millimeters) 29 TIME DELA Y RELA YS DELAY RELAYS Product Summar y Summary Macromatic offers a wide variety of time delay relays and accessories. Each one has different features and operating characteristics, allowing you to choose the exact product to meet your needs. Our time delay relays are available in either programmable or non-programmable versions. We offer both single or multiple function time delay relays. Choose between SPDT or DPDT relay outputs. Time delay relays are available as plug-in units for use with industry standard 8 & 11 pin octal or 11 pin blade sockets, or as an open board version for OEM applications. Choose between analog or digital-set time delay relays. Refer to the Selection Table on these two pages for more information. Series Standard Non-Programmable Single-Range Plug-in Time Ranger Multi-Range Programmable Plug-in Compact Non-Programmable Single-Range Plug-in TR-5 TR-6 SS-6 & SS-8 On Delay Interval On Off Delay Single Shot * * * * * * * * Timing Ranges Available 20 separate timing ranges from 0.02 Seconds to 24 Hours 16 field-programmable timing ranges covering up to 2 Hours (24 Hours on Dual Knob units) in one unit 6 separate timing ranges from 0.02 to 300 Seconds Output Contacts DPDT or SPDT 10A @ 240V AC 10A @ 28V DC 1/2HP @ 240V AC 1/3HP @ 120V AC B300/R300 DPDT 10A @ 240V AC 10A @ 28V DC 1/2HP @ 240V AC 1/3HP @ 120V AC B300/R300 SPDT 5A @ 120V AC 5A @ 28V DC 1/6HP @ 120V AC 12V AC/DC, 24V AC/DC, 120V AC/DC & 240V AC 12V AC/DC, 24V AC/DC, 120V AC/DC & 240V AC 12V AC/DC, 24V AC/DC & 120V AC Input Voltages * * * * * * * * On Delay Interval On Flasher Off Delay Single Shot Watchdog Repeat Cycle Delayed Interval * * * * On Delay Interval On Flasher Off Delay Single Shot Watchdog Repeat Cycle Delayed Interval Timing Functions Available Approvals with appropriate socket See Page 30 34-39 with appropriate socket 40-43 with appropriate socket 44 TIME DELA Y RELA YS DELAY RELAYS Product Summar y Summary See pages 32 & 33 for a detailed description of all timing functions available. If you have any questions regarding the selection or application of time delay relays, either visit our on-line Technical Resource Center (www.macromatic.com) or call us at 800-238-7474. Need modifications such as fixed time delays, remote adjustments or special pin configurations? We can do most of these modifications within our normal lead-times. See pages 50 & 51 for more information. Spade Base Non-Programmable Single Range Plug-in Time Ranger Digital-Set Multi-Range Programmable Plug-in Time Ranger III Digital-Set Multi-Function Multi-Range Programmable SS-4 TD-7 981 Series Timing Functions Available * On Delay * Off Delay * * * * * On Delay Interval On Flasher Off Delay Single Shot Available in both single function & multifunction All in One Unit: * On Delay * Interval On * Flasher * Off Delay (2 versions) * Interval On/Off Delay * On Delay/Off Delay * Delayed Interval Timing Ranges Available 3 separate timing ranges from 0.1 to 300 Seconds 0.05 Seconds to 999 Hours programmable timing range 0.1 Seconds to 9,999 Hours programmable timing range Output Contacts DPDT 12A @ 240V AC 12A @ 30V DC 1/2HP @ 240V AC B300/R300 DPDT 10A @ 240V AC 10A @ 28V DC 1/2HP @ 240V AC 1/3HP @ 120V AC B300/R300 SPDT 3A @ 240V AC 5A @ 30V DC 1/2HP @ 240V AC 12V AC/DC, 24V AC/DC & 120V AC 12V AC/DC, 24V AC/DC, 120V AC/DC & 240V AC 24-240V AC & 12-240V DC in one unit Input Voltages Approvals with appropriate socket See Page 45 with appropriate socket 46-47 48-49 31 TIME DELA Y RELA YS DELAY RELAYS Definition of Timing Functions Understanding the differences between all the functions available in time delay relays can sometimes be a daunting task. To begin with, time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on time. Typically, time delay relays are initiated or triggered by one of two methods: ! application of input voltage (On Delay, Interval On, Flasher, Repeat Cycle & Delayed Interval) ! opening or closing of a trigger signal (Off Delay, Single Shot, Watchdog & Triggered Delayed Interval) These trigger signals can be one of two designs: a control switch (dry contact), i.e., limit switch, push button, float switch, etc., or by voltage (commonly known as a power trigger). To help understand, some definitions are important: ! Input Voltage-control voltage applied to the input terminals. Depending on the function, input voltage will either initiate the unit or make it ready to initiate when a trigger signal is applied. ! Trigger Signal-on certain timing functions, a trigger signal is used to initiate the unit after input voltage has been applied. As noted above, this trigger signal can either be a control switch (dry contact switch) or a power trigger (voltage). ! Output (Load)-every time delay relay has an internal relay (usually mechanical) with contacts that open & close to control the load. They are represented by the dotted lines in the wiring diagrams. Note that the user must provide the voltage to power the load being switched by the output contacts of the time delay relay. Below and on the following page are both written and visual descriptions on how the common timing functions operate. A Timing Chart shows the relationship between Input Voltage, Trigger Signal (if present) and Output Contacts. If you cannot find a product to fit your requirements or have any questions, Macromatic’s Application Engineers offer technical information along with product selection and application assistance. Just call us at 800-238-7474 or e-mail us at tech-help@macromatic.com. ○ ○ Function Operation ON DELAY Delay on Operate Delay on Make Upon application of input voltage, the preset time begins. At the end of the preset time, the relay contacts transfer. Input voltage must be removed and reapplied to reset the time delay relay. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ SINGLE SHOT One Shot Momentary Interval 32 ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Upon application of input voltage, the time delay relay is ready to accept trigger signals. Upon application of the trigger signal, the relay contacts transfer and hold. Upon release of the trigger signal, the preset time begins and the relay contacts stay held. At the end of the preset time, the relay contacts return to their normal condition. Any application of the trigger signal will reset the time. OFF DELAY Delay on Release Delay on De-Energization Delay on Drop-Out ○ ○ Upon application of input voltage, the relay contacts transfer and the preset time begins. At the end of the preset time, the contacts return to their normal condition. Input voltage must be removed and reapplied to reset the time delay relay. INTERVAL ON Interval ○ ○ Timing Chart ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Upon application of input voltage, the time delay relay is ready to accept trigger signals. Upon application of the trigger signal, the relay contacts transfer and the preset time begins. During timeout, the trigger signal is ignored. The time delay relay is reset by applying the trigger signal when the relay is not energized. TIME DELA Y RELA YS DELAY RELAYS Definition of Timing Functions ○ ○ Function Operation WATCHDOG Retriggerable Single Shot Upon application of input voltage, the time delay relay is ready to accept trigger signals. Upon application of the trigger signal, the relay contacts transfer and the preset time begins. At the end of the preset time, the relay contacts return to their normal condition unless the trigger signal is opened and closed prior to time out (before preset time elapses). Continuous cycling of the trigger signal at a rate faster than the preset time will cause the relay contacts to remain closed. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Upon application of input voltage, a preset delay begins (OFF). At the end of the preset delay, the relay contacts transfer and remain in that condition for a second, independently adjustable preset time (ON). At the end of this time, the contacts drop out and the sequence stops. Input voltage must be removed and reapplied to reset the time delay relay. DELAYED INTERVAL Single Cycle ○ ○ Upon application of input voltage, the relay contacts transfer and a preset delay begins. At the end of the preset delay, the relay contacts drop out and remain in that condition for a second, independently adjustable preset time. At the end of this time, the relay contacts pull in and the sequence repeats until input voltage is removed. REPEAT CYCLE On/Off Delay ○ ○ Upon application of input voltage, a preset delay begins. At the end of the preset delay, the relay contacts transfer and remain in that condition for a second, independently adjustable preset time. At the end of this time, the relay contacts drop out and the sequence repeats until input voltage is removed. REPEAT CYCLE Off/On Delay ○ ○ Upon application of the input voltage, the preset time (T1) begins. At the end of the preset time, the relay contacts transfer and remain in that condition for the preset time (T1). At the end of this time, the relay contacts drop out and the sequence repeats until input voltage is removed. FLASHER ○ ○ Timing Chart ○ DELAYED INTERVAL (TRIGGERED) Single Cycle ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Upon application of input voltage, the time delay relay is ready to accept trigger signals. Upon application of the trigger signal, a preset delay begins (OFF). At the end of the preset delay, the relay contacts transfer and remain in that condition for a second, independently adjustable preset time (ON). At the end of the second preset time, the relay contacts return to their normal condition. During timing, the trigger signal is ignored. 33 TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in On Delay val & Flasher Delay,, Inter Interval ! Each unit has a single timing range ! Choose from 20 separate timing ranges from 0.02 Seconds to 24 Hours ! Uses industry-standard 8 pin octal sockets ! 10A DPDT output contacts FUNCTION " WIRING/ SOCKETS ! FROM TABLE BELOW ON DELAY 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-50222-** TR-50226-** TR-50228-** TR-50221-** INTERVAL ON 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-50522-** TR-50526-** TR-50528-** TR-50521-** FLASHER 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-50822-** TR-50826-** TR-50828-** TR-50821-** ! with appropriate socket SINGLE KNOB UNITS PRODUCT INPUT NUMBER ** COMPLETE PRODUCT VOLTAGE NUMBER USING 2 DIGIT CODE 8 PIN OCTAL ! 70169-D DIAGRAM 1 " See Pages 32-33 for definitions & explanations of Timing Functions. ! Note: if these products are ordered with the Remote Adjust Potentiometer modification (suffix -Rx), they will require an 11 pin octal socket−see Page 50 for more information. Sockets & Accessories−Page 58 Dimensions−Page 37 Application Data−Page 37 Standard Modifications−Pages 50-51 Timing Ranges ** TIMING RANGE TABLE COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE FROM TABLE BELOW i.e., TR-50222-04 Time Delay Range 0.02 - 2 Sec. 0.05 - 5 Sec. 0.1 - 10 Sec. 0.15 - 15 Sec. 0.3 - 30 Sec. 0.6 - 60 Sec. 1.2 - 120 Sec. 1.8 - 180 Sec. 3 - 300 Sec. 4.5 - 450 Sec. Code 03 04 05 06 07 08 09 10 12 13 Time Delay Range Code 6 Sec. - 10 Min. 22 9 Sec. - 15 Min. 14 0.3 - 30 Min. 15 0.6 - 60 Min. 16 1.2 - 120 Min. 17 1.8 - 180 Min. 18 2.4 Min. - 4 Hr. 19 4.8 Min. - 8 Hr. 20 7.2 Min. - 12 Hr. 21 14.4 Min. - 24 Hr. 23 For Fixed Time Delay (at no additional charge), add suffix “F” and time delay desired to basic Product Number, i.e., TR-50222F5S is an On Delay with a time delay fixed at 5 seconds. 800-238-7474 www.macromatic.com whats-up@macromatic.com 34 TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in Off Delay atchdog Delay,, Single Shot & W Watchdog FUNCTION " ! SINGLE KNOB UNITS PRODUCT INPUT NUMBER ** COMPLETE PRODUCT VOLTAGE NUMBER USING 2 DIGIT CODE WIRING/ SOCKETS FROM TABLE BELOW OFF DELAY Control Switch Trigger SINGLE SHOT Control Switch Trigger WATCHDOG Control Switch Trigger (Retriggerable Single Shot) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-51622-** TR-51626-** TR-51628-** TR-51621-** TR-51522-** TR-51526-** TR-51528-** TR-51521-** TR-51322-** TR-51326-** TR-51328-** TR-51321-** ! Each unit has a single timing range ! Choose from 20 separate timing ranges from 0.02 Seconds to 24 Hours ! Uses industry-standard 11 pin octal sockets ! 10A DPDT output contacts 11 PIN OCTAL 70170-D ! DIAGRAM 2 with appropriate socket OFF DELAY Power Trigger 120V AC/DC TR-51922-** 11 PIN OCTAL 12V AC/DC TR-51926-** 70170-D 24V AC/DC TR-51928-** 240V AC TR-51921-** SINGLE SHOT 120V AC/DC TR-51722-** Power Trigger 12V AC/DC TR-51726-** 24V AC/DC TR-51728-** 240V AC TR-51721-** WATCHDOG 120V AC/DC TR-51822-** Power Trigger 12V AC/DC TR-51826-** (Retriggerable 24V AC/DC TR-51828-** DIAGRAM 4 Single Shot) 240V AC TR-51821-** " See Pages 32-33 for definitions & explanations of Timing Functions. ! 8 Pin SPDT versions of these functions are available−see Page 38. Sockets & Accessories−Page 58 Dimensions−Page 37 Application Data−Page 37 Standard Modifications−Pages 50-51 Timing Ranges ** TIMING RANGE TABLE COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE FROM TABLE BELOW i.e., TR-51622-04 Time Delay Range 0.02 - 2 Sec. 0.05 - 5 Sec. 0.1 - 10 Sec. 0.15 - 15 Sec. 0.3 - 30 Sec. 0.6 - 60 Sec. 1.2 - 120 Sec. 1.8 - 180 Sec. 3 - 300 Sec. 4.5 - 450 Sec. Code 03 04 05 06 07 08 09 10 12 13 Time Delay Range Code 6 Sec. - 10 Min. 22 9 Sec. - 15 Min. 14 0.3 - 30 Min. 15 0.6 - 60 Min. 16 1.2 - 120 Min. 17 1.8 - 180 Min. 18 2.4 Min. - 4 Hr. 19 4.8 Min. - 8 Hr. 20 7.2 Min. - 12 Hr. 21 14.4 Min. - 24 Hr. 23 For Fixed Time Delay (at no additional charge), add suffix “F” and time delay desired to basic Product Number, i.e., TR-51622-F5S is an Off Delay with a time delay fixed at 5 seconds. 800-238-7474 www.macromatic.com whats-up@macromatic.com 35 TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in Repeat Cycle & Delayed Inter val Interval ! DUAL KNOB UNITS * PRODUCT INPUT NUMBER ** COMPLETE PRODUCT VOLTAGE NUMBER USING 2 DIGIT CODE Each unit has a single timing range ! FUNCTION " Choose from 20 separate timing ranges from 0.02 Seconds to 24 Hours ! FROM TABLE BELOW Independently adjustable ON & OFF times on dual knob timers ! Uses industry-standard 8 or 11 pin octal sockets ! 10A DPDT output contacts WIRING/ SOCKET ! with appropriate socket REPEAT CYCLE (OFF Time First Followed By ON Time and Repeating) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-53122-** TR-53126-** TR-53128-** TR-53121-** REPEAT CYCLE (ON Time First Followed By OFF Time and Repeating) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-55122-** TR-55126-** TR-55128-** TR-55121-** DELAYED INTERVAL (OFF Time Followed by ON Time Followed by OFF State Until Reset) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-56122-** TR-56126-** TR-56128-** TR-56121-** DELAYED INTERVAL Control Switch Trigger (OFF Time Followed by ON Time Followed by OFF State Until Reset) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-56522-** TR-56526-** TR-56528-** TR-56521-** 8 PIN OCTAL 70169-D DIAGRAM 1 11 PIN OCTAL 70170-D DIAGRAM 2 * All Dual Knob units have independently selectable & adjustable ON & OFF times. To order a Dual Knob unit with the same ON & OFF timing ranges, complete the Product Number by adding one two-digit code from the table below, i.e., a TR-55122-08 is a Repeat Cycle unit with both the ON time & OFF time adjustable between 0.6 - 60 seconds. To order a Dual Knob unit with different ON & OFF timing ranges, complete the Product Number by adding two different two-digit codes from the table below. The first suffix indicates the first timing range of the unit and the second suffix indicates the second timing range, i.e., a TR-53122-05-12 is a Repeat Cycle unit with an OFF timing range first of 0.1-10 seconds and an ON timing range second of 3-300 seconds. " See Pages 32-33 for definitions & explanations of Timing Functions. Sockets & Accessories−Page 58 Dimensions−Page 37 Application Data−Page 37 Standard Modifications−Pages 50-51 Timing Ranges ** TIMING RANGE TABLE COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE FROM TABLE BELOW i.e., TR-55122-04 800-238-7474 www.macromatic.com whats-up@macromatic.com 36 Time Delay Range 0.02 - 2 Sec. 0.05 - 5 Sec. 0.1 - 10 Sec. 0.15 - 15 Sec. 0.3 - 30 Sec. 0.6 - 60 Sec. 1.2 - 120 Sec. 1.8 - 180 Sec. 3 - 300 Sec. 4.5 - 450 Sec. Code 03 04 05 06 07 08 09 10 12 13 Time Delay Range Code 6 Sec. - 10 Min. 22 9 Sec. - 15 Min. 14 0.3 - 30 Min. 15 0.6 - 60 Min. 16 1.2 - 120 Min. 17 1.8 - 180 Min. 18 2.4 Min. - 4 Hr. 19 4.8 Min. - 8 Hr. 20 7.2 Min. - 12 Hr. 21 14.4 Min. - 24 Hr. 23 For Fixed Time Delay (at no additional charge), add suffix “F” and time delay desired to basic Product Number, i.e., TR-53122F5S is a Repeat Cycle with a time delay fixed at 5 seconds. TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in Application Data & Dimensions Application Data Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. Load (Burden): 2 VA Setting Accuracy: Maximum Setting (Adjustable): +5%, Minimum Setting (Adjustable): +0%, Fixed Time Delay: > 2 Seconds 0.1 - 2 Seconds -0% -50% +1% +5% Repeat Accuracy (constant voltage and temperature): > 2 Seconds Delay +0.1% +2% 0.1 - 2 Seconds Delay Reset Time: On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds Off Delay/Single Shot/Watchdog: 0.04 Seconds Start-up Time: (Time from when power is applied until unit is timing) 120 & 240V units 0.05 Seconds 12, 24 & 48V units 0.08 Seconds Maintain Function Time: (Time unit continues to time after power is removed) 0.01 Seconds for all units Insulation Voltage: 2,000 volts Output Contacts: DPDT 10A @ 240V AC/28V DC, 1/2HP @ 240V AC, 1/3HP @ 120V AC B300 & R300; AC15 & DC13 Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Compatibility: On all units triggered by input voltage or by a control switch, do not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. On all units with a power trigger, do not use a solid state switch with leakage current exceeding 0.5ma. Contact Macromatic Controls for additional information. Triggering Off Delay, Single Shot or Watchdog Units: Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds. Approvals: File #E109466 File #LR45565 Temperature: 12-120V Input Voltage: -28o to 65oC (-18o to 150oF) 240V Input Voltage: -28o to 50oC (-18o to 122oF) Low Voltage & EMC Directives EN60947-1, EN60947-5-1 with appropriate socket File #E109466 Dimensions All Dimensions in Inches (Millimeters) 2.4 (60) 2.9 (74) 1.7 (43) 3.5 (89) 37 TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in 8 Pin SPDT Versions Off Delay atchdog Delay,, Single Shot & W Watchdog ! These are 8 pin 10A SPDT versions of our standard 11 pin DPDT products ! Each unit has a single timing range from 0.02 Seconds to 24 Hours ! Uses industry-standard 8 pin octal socket ! with appropriate socket FUNCTION " OFF DELAY Control Switch Trigger SINGLE SHOT Control Switch Trigger WATCHDOG Control Switch Trigger (Retriggerable Single Shot) OFF DELAY Power Trigger SINGLE SHOT PowerTrigger WATCHDOG Power Trigger (Retriggerable Single Shot) PRODUCT NUMBER ** INPUT VOLTAGE COMPLETE PRODUCT NUMBER USING 2 DIGIT CODE FROM TABLE BELOW 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-51662-** TR-51666-** TR-51668-** TR-51661-** TR-51562-** TR-51566-** TR-51568-** TR-51561-** TR-51362-** TR-51366-** TR-51368-** TR-51361-** 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-51962-** TR-51966-** TR-51968-** TR-51961-** TR-51762-** TR-51766-** TR-51768-** TR-51761-** TR-51862-** TR-51866-** TR-51868-** TR-51861-** WIRING/ SOCKETS ! 8 PIN OCTAL 70169-D ! DIAGRAM 11 8 PIN OCTAL 70169-D ! DIAGRAM 37 " See Pages 32-33 for definitions & explanations of Timing Functions. ! Note: if these products are ordered with the Remote Adjust Potentiometer modification (suffix -Rx), they will require an 11 pin octal socket−see Page 50 for more information. Sockets & Accessories−Page 58 Dimensions−Page 39 Application Data−Page 39 Standard Modifications−Pages 50-51 Timing Ranges ** TIMING RANGE TABLE COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE FROM TABLE BELOW i.e., TR-51662-04 800-238-7474 www.macromatic.com whats-up@macromatic.com 38 Time Delay Range 0.02 - 2 Sec. 0.05 - 5 Sec. 0.1 - 10 Sec. 0.15 - 15 Sec. 0.3 - 30 Sec. 0.6 - 60 Sec. 1.2 - 120 Sec. 1.8 - 180 Sec. 3 - 300 Sec. 4.5 - 450 Sec. Code 03 04 05 06 07 08 09 10 12 13 Time Delay Range Code 6 Sec. - 10 Min. 22 9 Sec. - 15 Min. 14 0.3 - 30 Min. 15 0.6 - 60 Min. 16 1.2 - 120 Min. 17 1.8 - 180 Min. 18 2.4 Min. - 4 Hr. 19 4.8 Min. - 8 Hr. 20 7.2 Min. - 12 Hr. 21 14.4 Min. - 24 Hr. 23 For Fixed Time Delay (at no additional charge), add suffix “F” and fixed time delay desired to basic Product Number,i.e., TR-51662-F5S is an Off Delay with a time delay fixed at 5 seconds. TIME DELA Y RELA YS DELAY RELAYS Non-Programmable Plug-in 8 Pin SPDT Versions Application Data & Dimensions Application Data Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. Load (Burden): 2 VA Setting Accuracy: Maximum Setting (Adjustable): +5%, Minimum Setting (Adjustable): +0%, Fixed Time Delay: > 2 Seconds 0.1 - 2 Seconds -0% -50% +1% +5% Repeat Accuracy (constant voltage and temperature): > 2 Seconds Delay +0.1% 0.1 - 2 Seconds Delay +2% Reset Time: Off Delay/Single Shot/Watchdog: 0.04 Seconds Start-up Time: (Time from when power is applied until unit is timing) 120 & 240V units 0.05 Seconds 12, 24 & 48V units 0.08 Seconds Maintain Function Time: (Time unit continues to time after power is removed) 0.01 Seconds for all units Temperature: 12-120V Input Voltage: -28o to 65oC (-18o to 150oF) 240V Input Voltage: -28o to 50oC (-18o to 122oF) Insulation Voltage: 2,000 volts Output Contacts: DPDT 10A @ 240V AC/28V DC, 1/2HP @ 240V AC, 1/3HP @ 120V AC B300 & R300; AC15 & DC13 Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Compatibility: On all units triggered by a control switch, do not use a solid state switch to initiate the timing sequence-problems with leakage current could occur. On all units with a power trigger, do not use a solid state switch with leakage current exceeding 0.5ma. Contact Macromatic Controls for additional information. Triggering Off Delay, Single Shot or Watchdog Units: Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds. Approvals: File #E109466 File #LR45565 Low Voltage & EMC Directives EN60947-1, EN60947-5-1 with appropriate socket File #E109466 Dimensions All Dimensions in Inches (Millimeters) 2.4 (60) 2.9 (74) 1.7 (43) 3.5 (89) 39 TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Programmable Multi-Range Plug-in On Delay val On & Flasher Delay,, Inter Interval ! Each unit has 16 timing ranges built-in ! Selecting a range is easy using a rotary switch (no math is required or DIP switches to set) ! Timing ranges up to 2 hours ! Uses industry-standard 8 pin octal sockets ! 10A DPDT output contacts SINGLE KNOB UNITS INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-60222 TR-60226 TR-60228 TR-60221 8 PIN OCTAL 70169-D INTERVAL ON 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-60522 TR-60526 TR-60528 TR-60521 FLASHER 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-60822 TR-60826 TR-60828 TR-60821 FUNCTION " ON DELAY ! with appropriate socket DIAGRAM 1 " See Pages 32-33 for definitions & explanations of Timing Functions. Sockets & Accessories−Page 58 Dimensions−Page 43 Application Data−Page 43 Standard Modifications−Pages 50-51 Timing Ranges Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top: SINGLE KNOB UNITS 800-238-7474 www.macromatic.com whats-up@macromatic.com 40 Dial Setting Timing Range A B C D E F G H I J K L M N O P 0.1 - 0.25 Sec. 0.2 - 0.5 Sec. 0.3 - 1 Sec. 0.5 - 2 Sec. 1 - 4 Sec. 2 - 8 Sec. 4 - 15 Sec. 8 - 30 Sec. 15 - 60 Sec. 30 - 120 Sec. 1 - 4 Min. 2 - 8 Min. 4 - 15 Min. 8 - 30 Min. 15 - 60 Min. 30 - 120 Min. TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Programmable Multi-Range Plug-in Off Delay atchdog Delay,, Single Shot & W Watchdog SINGLE KNOB UNITS FUNCTION " OFF DELAY Control Switch Trigger SINGLE SHOT Control Switch Trigger WATCHDOG Control Switch Trigger (Retriggerable Single Shot) OFF DELAY Power Trigger SINGLE SHOT Power Trigger WATCHDOG Power Trigger (Retriggerable Single Shot) INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-61622 TR-61626 TR-61628 TR-61621 TR-61522 TR-61526 TR-61528 TR-61521 TR-61322 TR-61326 TR-61328 TR-61321 11 PIN OCTAL 70170-D 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-61922 TR-61926 TR-61928 TR-61921 TR-61722 TR-61726 TR-61728 TR-61721 TR-61822 TR-61826 TR-61828 TR-61821 11 PIN OCTAL 70170-D DIAGRAM 2 ! Each unit has 16 timing ranges built-in ! Selecting a range is easy using a rotary switch (no math is required or DIP switches to set) ! Timing ranges up to 2 hours ! Uses industry-standard 11 pin octal sockets ! 10A DPDT output contacts ! with appropriate socket DIAGRAM 4 " See Pages 32-33 for definitions & explanations of Timing Functions. Sockets & Accessories−Page 58 Dimensions−Page 43 Application Data−Page 43 Standard Modifications−Pages 50-51 Timing Ranges Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top: SINGLE KNOB UNITS Dial Setting Timing Range A B C D E F G H I J K L M N O P 0.1 - 0.25 Sec. 0.2 - 0.5 Sec. 0.3 - 1 Sec. 0.5 - 2 Sec. 1 - 4 Sec. 2 - 8 Sec. 4 - 15 Sec. 8 - 30 Sec. 15 - 60 Sec. 30 - 120 Sec. 1 - 4 Min. 2 - 8 Min. 4 - 15 Min. 8 - 30 Min. 15 - 60 Min. 30 - 120 Min. 800-238-7474 www.macromatic.com whats-up@macromatic.com 41 TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Programmable Multi-Range Plug-in Repeat Cycle & Delayed Inter val Interval ! Each unit has 16 timing ranges built-in ! Selecting a range is easy using a rotary switch (no math is required or DIP switches to set) ! Timing ranges up to 24 hours ! Independently selectable & adjustable ON & OFF times on dual knob timers ! Uses industry-standard 8 or 11 pin octal sockets ! 10A DPDT output contacts ! with appropriate socket DUAL KNOB UNITS * FUNCTION " INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS REPEAT CYCLE (OFF Time First Followed By ON Time and Repeating) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-63122 TR-63126 TR-63128 TR-63121 8 PIN OCTAL 70169-D REPEAT CYCLE (ON Time First Followed By OFF Time and Repeating) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-65122 TR-65126 TR-65128 TR-65121 DELAYED INTERVAL (OFF Time Followed by ON Time Followed by OFF State Until Reset) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-66122 TR-66126 TR-66128 TR-66121 DELAYED INTERVAL Control Switch Trigger (OFF Time / ON Time / OFF State Until Reset) 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TR-66522 TR-66526 TR-66528 TR-66521 DIAGRAM 1 11 PIN OCTAL 70170-D DIAGRAM 2 * All Dual Knob units have independently selectable & adjustable ON & OFF times. " See Pages 32-33 for definitions & explanations of Timing Functions. Sockets & Accessories−Page 58 Dimensions−Page 43 Application Data−Page 43 Standard Modifications−Pages 50-51 Timing Ranges Select one of the 16 built-in time ranges by setting the rotary switch per a chart on the unit and adjust within that range using the knob on top: DUAL KNOB UNITS 800-238-7474 www.macromatic.com whats-up@macromatic.com 42 Dial Setting Timing Range A B C D E F G H I J K L M N O P 0.6 - 2.5 Sec. 1.5 - 5 Sec. 2.5 - 10.5 Sec. 5 - 21 Sec. 10 - 42 Sec. 0.4 - 1.4 Min. 0.7 - 2.8 Min. 1.5 - 5.5 Min. 3 - 11 Min. 5.5 - 22.5 Min. 11 - 45 Min. 0.4 - 1.5 Hr. 0.8 - 3 Hr. 1.5 - 6 Hr. 3 - 12 Hr. 6 - 24 Hr. TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Programmable Multi-Range Plug-in Application Data & Dimensions Application Data Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. Load (Burden): 2 VA Setting Accuracy: Maximum Setting (Adjustable): +5%, Minimum Setting (Adjustable): +0%, Fixed Time Delay: > 2 Seconds 0.1 - 2 Seconds -0% -50% +1% +5% Repeat Accuracy (constant voltage and temperature): > 2 Seconds Delay +0.1% 0.1 - 2 Seconds Delay +2% Reset Time: On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds Off Delay/Single Shot/Watchdog: 0.04 Seconds Start-up Time: (Time from when power is applied until unit is timing) 120 & 240V units 0.05 Seconds 12, 24 & 48V units 0.08 Seconds Maintain Function Time: (Time unit continues to time after power is removed) 0.01 Seconds for all units Insulation Voltage: 2,000 volts Output Contacts: DPDT 10A @ 240V AC/28V DC, 1/2HP @ 240V AC, 1/3HP @ 120V AC B300 & R300; AC15 & DC13 Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Compatibility: On all units triggered by input voltage or by a control switch, do not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. On all units with a power trigger, do not use a solid state switch with leakage current exceeding 0.5ma. Contact Macromatic Controls for additional information. Triggering Off Delay, Single Shot or Watchdog Units: Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds. Approvals: File #E109466 File #LR45565 Temperature: 12-120V Input Voltage: -28o to 65oC (-18o to 150oF) 240V Input Voltage: -28o to 50oC (-18o to 122oF) Low Voltage & EMC Directives EN60947-1, EN60947-5-1 with appropriate socket File #E109466 Dimensions All Dimensions in Inches (Millimeters) 2.4 (60) 2.9 (74) 1.7 (43) 3.5 (89) 43 TIME DELA Y RELA YS DELAY RELAYS Compact Non-Programmable Plug-in 1.4 (36) 2.2 (56) 2.4 (61) 1.4 (36) All Dimensions in Inches (Millimeters) ! Compact, economical design with standard features for basic applications ! 6 separate timing ranges from 0.2 to 300 seconds ! 5A SPDT output contacts ! Uses industry-standard 8 pin octal sockets FUNCTION " PRODUCT NUMBER ** INPUT VOLTAGE WIRING/ SOCKET# COMPLETE PRODUCT NUMBER USING 2 DIGIT CODE FROM TABLE BELOW LEFT ON DELAY 120V AC 12V AC/DC 24V AC/DC SS-6262-** SS-6266-** SS-6268-** INTERVAL ON 120V AC 12V AC/DC 24V AC/DC SS-8062-** SS-8066-** SS-8068-** OFF DELAY 120V AC 12V AC/DC 24V AC/DC SS-8562-** SS-8566-** SS-8568-** SINGLE SHOT 120V AC 12V AC/DC 24V AC/DC SS-8762-** SS-8766-** SS-8768-** 8 Pin Octal 70169-D ! DIAGRAM 5 with appropriate socket Timing Ranges ** TIMING RANGE TABLE COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE FROM TABLE BELOW i.e., SS-6262-04 Time Delay Range 0.2 - 5 Sec. 0.5 - 15 Sec. 1 - 30 Sec. 2 - 60 Sec. 6 - 180 Sec. 10 - 300 Sec. Code 04 06 07 08 10 12 For Fixed Time Delay: (at no additional charge), add suffix “F” and time delay desired to basic Product Number, i.e., SS-6262-F5S is an On Delay fixed at 5 seconds. DIAGRAM 6 " See Pages 32-33 for definitions & explanations of Timing Functions. # See Page 58 for Sockets & Accessories. Application Data Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. Load (Burden): Less than 3 VA Setting Accuracy: Maximum Setting: +10%, -0% Minimum Setting: +0%, -50% Fixed Time Delay: > 2 Seconds 0.1 - 2 Seconds Repeat Accuracy: > 2 Seconds Delay 0.1 - 2 Seconds Delay 800-238-7474 www.macromatic.com whats-up@macromatic.com 44 8 Pin Octal 70169-D Reset Time: 0.2 Seconds +2% +5% +2% +5% Temperature: 0o to 60oC (32o to 140oF) Compatibility: Do not use a solid state switch to initiate the timing sequence-problems with leakage current could occur. Contact Macromatic Controls for additional information. Transient Protection: 10,000 volts for 20 microseconds Output Contacts: SPDT 5A Resistive @ 120V AC/ 28V DC, 1/6HP @ 120VAC Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Triggering Off Delay & Single Shot Units: Timing sequence must be initiated only after input Approvals: power is applied to unit. Minimum required File #E109466 trigger switch closure time is 0.1 seconds. with appropriate socket TIME DELA Y RELA YS DELAY RELAYS Non-Programmable with Quick Connect Terminals 2.4 (60) 2.9 (74) 1.7 (43) 3.5 (89) All Dimensions in Inches (Millimeters) FUNCTION " ON DELAY INPUT VOLTAGE TIME DELAY RANGE PRODUCT NUMBER WIRING/ SOCKET# ! Industry-standard .187" quick connect terminals 120V AC/DC 0.1-10 Sec. 1-180 Sec. 3-300 Sec. SS-40222-05 SS-40222-10 SS-40222-12 .187” Quick Connect 70171-D ! On Delay or Off Delay timing functions ! 3 separate timing ranges up to 300 seconds 0.1-10 Sec. 1-180 Sec. 3-300 Sec. SS-40228-05 SS-40228-10 SS-40228-12 ! 12A DPDT output contacts 24V AC/DC ! DIAGRAM 25 OFF DELAY 120V AC/DC 0.1-10 Sec. 1-180 Sec. 3-300 Sec. SS-41622-05 SS-41622-10 SS-41622-12 24V AC/DC 0.1-10 Sec. 1-180 Sec. 3-300 Sec. SS-41628-05 SS-41628-10 SS-41628-12 .187” Quick Connect 70171-D with appropriate socket DIAGRAM 26 " See Pages 32-33 for definitions & explanations of Timing Functions. # See Page 58 for Sockets & Accessories For Fixed Time Delay: (at no additional charge), add letter "F" and time delay desired to basic Product Number, i.e., SS-40222-F5S, is an On Delay with time delay fixed at 5 seconds. Application Data Voltage Tolerance: Triggering Off Delay Timers: AC Operation: +10/-15% of nominal at 50/60 Hz. Timing sequence must be initiated only DC Operation: +10/-15% of nominal. after input power is applied to unit. Minimum required trigger switch closure Load (Burden): time is 0.1 seconds. Less than 3 VA. Transient Protection: Setting Accuracy: 10,000 volts for 20 microseconds Maximum Setting: +10%, -0% Minimum Setting: +0%, -50% Output Contacts: Fixed Time Delay: > 2 Seconds +2% DPDT 12A Resistive @ 240V AC/ 0.1 - 2 Seconds +5% 30V DC, 1/2HP @240VAC Repeat Accuracy: > 2 Seconds Delay 0.1 - 2 Seconds Delay +2% +5% Life: Mechanical: 10,000,000 operations Full Load: 30,000 operations Compatibility: Approvals: On Off Delay units, do not use a solid state switch to initiate the timing sequence-problems with leakage current could occur. Contact File #E109466 Macromatic Controls for additional information. Recycle Time: 0.1 Seconds Temperature: -28o to 65oC (-20o to 150oF) File #LR45565 Low Voltage & EMC Directives EN60947-1, EN60947-5-1 800-238-7474 www.macromatic.com with appropriate socket whats-up@macromatic.com 45 TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Digital-Set Programmable Multi-Range Plug-in Multi-Function ! Available in either SingleFunction or Multi-Function versions (with five userselectable modes) ! Pushbutton Thumbwheels for digital set of time delay & function (TD-781 series only) ! 50ms - 999 hour programmable time range ! Uses industry-standard 8 or 11 pin octal sockets ! 10A DPDT output contacts ! LED indicates timing mode and time out conditions ! Single-Function The TD-7 series of time delay relays offer an easy and accurate way to select any time delay between 50ms & 999 hours. Programming is accomplished by using a pushbutton thumbwheel to select one of seven built-in time ranges and three pushbutton thumbwheels to digitally set the time delay required. This method provides a greater setting accuracy than is found on other units with an analog potentiometer. An LED indicates timing mode and time out condition. The TD-7 series comes in two versions: a single function product or a multi-function product. The TD-781 multi-function unit has a fifth pushbutton thumbwheel to select one of five built-in functions. Multi-Function Product FUNCTION MULTI-FUNCTION (5 Field-Selectable Functions in one unit) ! On Delay ! Off Delay ! Interval On ! Single Shot ! Flasher INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-78122 TD-78126 TD-78128 TD-78121 11 PIN OCTAL 70170-D with appropriate socket DIAGRAM 121 Single Function Products INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-70222 TD-70226 TD-70228 TD-70221 8 PIN OCTAL 70169-D INTERVAL ON 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-70522 TD-70526 TD-70528 TD-70521 FLASHER 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-70822 TD-70826 TD-70828 TD-70821 OFF DELAY 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-71622 TD-71626 TD-71628 TD-71621 SINGLE SHOT 120V AC/DC 12V AC/DC 24V AC/DC 240V AC TD-71522 TD-71526 TD-71528 TD-71521 FUNCTION ON DELAY DIAGRAM 1 11 PIN OCTAL 70170-D 800-238-7474 DIAGRAM 2 www.macromatic.com whats-up@macromatic.com 46 Sockets & Accessories−Page 58 Dimensions−Page 47 Application Data−Page 47 TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM Digital-Set Programmable Multi-Range Plug-in Application Data & Dimensions Application Data Voltage Tolerance: AC Operation: +10/-15% of nominal at 50/60 Hz. DC Operation: +10/-15% of nominal. Load (Burden): 3 VA Setting Accuracy: +1% of set time or +50ms, whichever is greater. Repeat Accuracy (constant voltage and temperature): +0.1% of set time or +0.02 seconds, whichever is greater. Reset Time: On Delay/Interval/Flasher: 0.1 Seconds Off Delay/Single Shot: 0.04 Seconds Start-up Time: (Time from when power is applied until unit is timing) 120 & 240V units 0.05 Seconds 12, 24 & 48V units 0.08 Seconds Maintain Function Time: (Time unit continues to time after power is removed) 0.01 Seconds for all units Temperature: 12-120V Input Voltage: -28o to 65oC (-18o to 150oF) 240V Input Voltage: -28o to 50oC (-18o to 122oF) Output Contacts: DPDT 10A @ 240V AC/28V DC, 1/2HP @ 240V AC, 1/3HP @ 120V AC B300 & R300; AC15 & DC13 Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Compatibility: Do not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. Contact Macromatic Controls for additional information. Triggering Off Delay or Single Shot Units: Timing sequence must be initiated only after input voltage is applied to unit. Minimum required trigger switch closure time is 0.1 seconds. LED: Flasher Mode: Flashes during “ON” time; continuous on during “OFF” time All Other Modes: Flashes during timing; continuous on after time out. Approvals: File #E109466 Insulation Voltage: 2,000 volts File #LR45565 Low Voltage & EMC Directives EN60947-1, EN60947-5-1 with appropriate socket File #E109466 Dimensions All Dimensions in Inches (Millimeters) 2.4 (60) 2.9 (74) 1.7 (43) 3.0 (77) 47 TIME DELA Y RELA YS DELAY RELAYS Time Ranger TM III Digital-Set Multi-Function Multi-Range All dimensions are inches (millimeters) ! 8 field-selectable functions in one unit ! Push-button thumbwheels for digital-setting of time delay ! Universal AC/DC input voltage ! LCD display ! 0.1 Second to 9,990 Hours programmable timing range ! Panel, track or surface mounting ! 1/16 DIN style case ! 3A SPDT output contacts FUNCTION INPUT VOLTAGE PRODUCT NUMBER WIRING/ SOCKETS" 8 FIELDSELECTABLE FUNCTIONS! 24-240V AC 50/60Hz & 12-240V DC 9816U1 SEE DIAGRAMS ON PAGE 49 11 Pin Octal ! Functions Include: On Delay, Flasher, Interval/Off Delay, Off Delay (2 Versions), Interval, Delayed Interval and On Delay/Off Delay (see Page 49 for Further Details) " See below for Sockets & Accessories. Application Data Voltage Tolerance: +10% of rated voltage. Temperature: -10o to 55oC (14o to 131oF) Load (Burden): Less than 3 VA Output Contacts: SPDT 3A Resistive @ 250V AC SPDT 5A Resistive @ 28V DC Repeat Accuracy: +0.3%, +0.05 seconds (includes variation due to voltage and temperature changes). Setting Accuracy: +0.5%, +0.05 seconds maximum. ! Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations Approvals: Recycle Time: 0.5 seconds maximum. File #E170213 File #LR701134 ○ ○ ○ ○ ○ ○ DESCRIPTION 11 Pin Octal Socket (Surface or Track Mounting) 11 Pin Octal Socket (Back Mounting) Panel Mounting Adaptor Protective Cover " See Page 58 ○ ○ ○ Sockets & Accessories PRODUCT NUMBER 70170-D" 70300 70310 70320 PANEL CUTOUT 70300 70310 800-238-7474 www.macromatic.com whats-up@macromatic.com 48 70320 All Dimensions in Inches (Millimeters) TIME DELA Y RELA YS DELAY RELAYS Time Ranger FUNCTION MODE A ○ ○ ○ ○ MODE B ○ ○ ○ ○ ○ ○ ○ ○ Standard (Diagram 7) ○ ○ Flasher ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ TIMING CHART Upon application of control power, the preset time begins. At the end of the preset time, the relay contacts transfer. Control power must be removed and reapplied to reset the time delay relay. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Triggered (Diagram 9) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure of the Start switch, the preset time begins. At the end of the preset time, the relay contacts transfer. Any closure of the Start switch is ignored until reset. The time delay relay is reset by closing the Reset switch or removing the control power. Standard (Diagram 7) Upon application of control power, the preset time begins. At the end of the preset time, the relay contacts transfer and remain in that condition for the preset time. At the end of this time, the relay contacts return to their normal condition and the sequence repeats until control power is removed. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Triggered (Diagram 9) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure of the Start switch, the preset time begins. At the end of the preset time, the relay contacts transfer and remain in that condition for the preset time. At the end of this time, the relay contacts return to their normal condition and the sequence repeats until the Reset switch is closed or control power is removed. MODE C Interval/ Off-Delay (Diagram 8) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure or opening of the Start switch, the relay contacts transfer and the preset time begins. At the end of the preset time, the relay contacts return to their normal condition. Any closure or opening of the Start switch during timing causes the time to reset. MODE D Off-Delay (I) (Diagram 8) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure of the Start switch, the relay contacts transfer and hold. Upon release of the Start switch, the preset time begins. At the end of the preset time, the relay contacts return to their normal condition. Any application of the Start switch will reset the time. MODE E Interval Standard (Diagram 7) Upon application of control power, the relay contacts transfer and the preset time begins. At the end of the preset time, the contacts return to their normal condition. Control power must be removed and reapplied to reset the time delay relay. ○ ○ ○ ○ MODE F ○ ○ III Digital-Set Multi-Function Multi-Range OPERATION On-Delay ○ TM ○ ○ ○ ○ ○ ○ ○ ○ ○ Delayed Interval ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Triggered (Diagram 9) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure of the Start switch, the relay contacts transfer and the preset time begins. At the end of the preset time, the contacts return to their normal condition. Any closure of the Start switch is ignored until reset. The time delay relay is reset by closing the Reset switch or removing the control power. Standard (Diagram 7) Upon application of control power, the preset time begins. At the end of the preset time, the relay contacts transfer and remain in that condition for the preset time. At the end of this time, the relay contacts return to their normal condition and the sequence stops. Power must be removed and reapplied to reset the time delay relay. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Triggered (Diagram 9) Upon application of control power, the time delay relay is ready to accept trigger signals. At the end of the preset time, the relay contacts transfer and remain in that condition for the preset time. At the end of this time, the relay contacts return to their normal condition and the sequence stops. Power must be removed and reapplied to reset the time delay relay. MODE G On-Delay/ Off-Delay (Diagram 8) Upon application of control power, the time delay relay is ready to accept trigger signals. Upon closure of the Start switch, the preset time begins. At the end of the preset time, the relay contacts will transfer. Upon opening of the Start switch, the preset time begins. At the end of the preset time, the output contacts return to their normal condition. MODE H Off-Delay (II) (Diagram 8) Upon application of control power, the time delay relay is ready to accept trigger signals. Closure of the Start switch is ignored. Upon release of the Start switch, the relay contacts transfer and the preset time begins. At the end of the preset time, the relay contacts return to their normal condition. Opening the Start switch during timing resets the time. DIAGRAM 7 DIAGRAM 8 DIAGRAM 9 49 TIME DELA Y RELA YS DELAY RELAYS Standard Modifications All of our Catalog-Listed Time Delay Relays can be adapted for different applications. Below is a list of various Situations, Solutions and Ordering Information to illustrate many of these modifications. Please contact Macromatic if you have any questions or need additional information before ordering any products with these modifications. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Solution: Macromatic can build a time delay relay triggered by a control switch (i.e., Off Delay, Single Shot, Watchdog) with any pin configuration required to meet your application. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 50 Normal 11 pin product with configuration for Remote Adjust (2-6 Control Switch) ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ To order: Any time delay relay with a remote adjustment feature and an 11 pin header, use the following chart to determine which suffix matches the value of the remote potentiometer, i.e., a TR-50222-04R6 is an On Delay with an 11 pin header, setup for a 750K remote potentiometer to be connected to pins 5 & 7: Remote Pot Add Remote Pot Value Suffix Value 250K R3 1.5M 300K R4 2M 500K ** R5 2.5M 750K R6 5M 1M R7 ○ ○ ○ ○ ○ Normal 8 pin product with 11 pin configuration for Remote Adjust ○ ○ ○ ○ ○ Solution: Macromatic can build most time delay relays with an optional remote adjustment feature. The potentiometer usually supplied with the product is removed, and the product is setup for use with a customer-supplied remote potentiometer to be connected to pins 5 & 7. Units that are normally 8 pin will have an 11 pin configuration. Units that are normally 11 pin will have the control switch connected between pins 2 & 6 (instead of the standard 5 & 6). For other control switch pin configurations, contact Macromatic for ordering information. ○ Situation B: I need to replace a time delay relay that is already connected to a remote potentiometer with a known value. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Situation A: I want to mount a time delay relay in an enclosure, but would like to adjust the time delay from outside the enclosure instead of having to open the door. ○ * NOTE: These suffixes apply only to different control switch pin configuations. The input voltage and output pin configurations remain as shown at left. For other configurations, contact Macromatic. NOTE: The configuration of the input voltage and output contacts has not been changed. ○ ○ Standard 11 pin modified with a 6-10 control switch (Suffix T8) ○ Standard 11 pin time delay relay, i.e., Off Delay, Single Shot, or Watchdog ○ Control Control Switch Switch Connected Add Connected Add To Pins Suffix * To Pins Suffx * 2-5 T1 5-10 T6 2-6 T2 6-7 T7 2-7 T3 6-10 T8 5-7 T5 7-10 T9 ○ Standard 11 pin modified with a 2-6 control switch (Suffix T2) ○ To order: Any time delay relay with a special control switch configuration, use the following chart to determine which suffix provides the correct configuration needed, i.e., a TR-51522-05T9 is a Single Shot with the control switch between pins 7 & 10 instead of 5 & 6: ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Situation: I have an 11 pin time delay relay where all the pins match the wiring diagram shown in your catalog (and below) except the control switch (trigger switch) is connected to pins other than pins 5 and 6. To order: Any time delay relay fixed at a factory set delay time, replace the normal two digit suffix indicating adjustable time range with the suffix Fxxt where xx is the specific time delay desired and t is the time interval (seconds, minutes or hours), i.e., a TR-51622-F10S is an Off Delay fixed at 10 Seconds. ○ ○ Solution: Macromatic offers products where the adjustment potentiometer is removed and the unit comes with one specific (non-adjustable) time range, i.e., 5 seconds, 1 minute, etc. These are products with a “fixed” time delay. ○ Situation: I know exactly what time delay I need and therefore, do not need a unit with an adjustable time range. Add Suffix R8 R9 R10 R11 ** NOTE: A 500K potentiometer (R5) is the only value that can be used with a Time Ranger Programmable Time Delay Relay (those catalog numbers that begin with a TR-6). TIME DELA Y RELA YS DELAY RELAYS Standard Modifications Situation: I want to use an 8 pin socket, but according to your catalog, the time delay relay I have selected is an 11 pin unit. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Solution: Macromatic can build any TR Series time delay relay that is normally an 11 pin product with an 8 pin base. This modified product will be SPDT only instead of the normal DPDT of the 11 pin version. ○ Situation: I have an 11 pin socket in place and wired, but according to your catalog, the time delay relay I want to use is an 8 pin unit. ○ ○ ○ 11 Pin DPDT ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Situation: I need the time delay relay to recycle faster than the factory standard of 0.1 seconds. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ 8 Pin SPDT ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Special 11 Pin DPDT ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ To order: Any time delay relay with a fast reset time, add the suffix N to the end of the Product Number, i.e., a TR-60222-N is an programmable On Delay with a fast reset time of 0.05 seconds. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ To order: Any single knob programmable Time Ranger time delay relay with a 24 hour time range, add the suffix U to the end of the Product Number, i.e., a TR-60222-U would be an On Delay with a programmable time range of 0.6 seconds - 24 hours. Solution: Macromatic can modify our single knob programmable Time Ranger products that normally come with a 2 hour maximum setting to have a range of 0.6 seconds to 24 hours (same as our dual knob units). Situation: I have a power triggered time delay relay (Off Delay, Single Shot or Watchdog) with 120VAC input voltage, but would like to trigger it with a 5VDC computer generated voltage. ○ To order: Any standard 8 Pin time delay relay modified to an 11 Pin base, add the suffix H to the end of the Product Number, i.e., a TR-60222-H is a programmable On Delay time delay relay with an 11 pin base configured as shown at left. Solution: A time delay relay with a fast reset of 0.05 seconds is available. Situation: I need a longer time delay range than the 2 hour maximum available on the Macromatic programmable Time Ranger single knob functions, i.e., On Delay, Interval On, Off Delay, etc. ○ ○ Solution: Macromatic can build any time delay relay that is normally an 8 pin product with an 11 pin base. Standard 8 Pin DPDT ○ ○ To order: See Page 38 for ordering information. NOTE: this option is available on TR Series products only. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ To order: Any time delay relay with a special power trigger voltage, use the following chart to determine which suffix provides the correct power trigger voltage, i.e., a TR-51922-05TV05 is a Power Triggered Off Delay with 120V input voltage and a 5V trigger voltage: Voltage Input Add Needed (AC/DC) Suffix 5 TV05 12 TV12 24 TV24 120 TV120 Other Call Macromatic ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Solution: As standard, power triggered time delay relays must use the same voltage for both input voltage & trigger voltage. However, Macromatic offers an option on any power triggered unit to have a voltage different than the input voltage. Normal Power Trigger ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Situation: The control switch used to initiate a time delay relay is a great distance from the product and I am experiencing problems triggering the relay. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Special Power Trigger ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Solution: Macromatic offers a long distance control switch option. This option will minimize the problems relating to noise that could caused false triggering of the time delay relay. ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ To order: Any time delay relay with a long distance control switch option, add the suffix Y to the end of the Product Number, i.e., a TR-61622-Y is a programmable Off Delay with a long distance control switch. 51 AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 1 Switch Applications SPDT or DPDT ! For duplex loads ! Works with 1 Control Switch ! Control voltages of 12, 24, 120 & 240V AC ! Compact plug-in design utilizing industry-standard 8 or 11 pin octal socket ! 10A SPDT or DPDT Output Configuration ! Optional low profile selector switch to lock in one sequence ! 2 LED’s indicate relay status ! with appropriate socket Alternating Relays are used in special applications where the optimization of load usage is required by equalizing the run time of two loads. They are also used where additional capacity is required in case of excess load requirements. This alternating action is initiated by a control switch, such as a float switch, manual switch, timing relay, pressure switch, or other isolated contact. Each time the initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay. The Alternating Relays listed on this page are used with one control switch & available in either SPDT or DPDT output configurations. See "Typical Installations" on Page 53 for more information. For products with DPDT Cross-Wired output configurations to be used with one or two control switches (LEAD-LAG), see Page 54. Each version is available with an optional three position selector switch. This allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the Alternating Relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. The selector switch has a low profile to prevent any accidental changes in status. OUTPUT CONTACTS SPDT w/o Selector Switch SPDT w/ Selector Switch DPDT w/o Selector Switch DPDT w/ Selector Switch CONTROL VOLTAGE PRODUCT NUMBER 12V AC 24V AC 120V AC 240V AC ARP012A6 ARP024A6 ARP120A6 ARP240A6 8 Pin Octal 70169-D 12V AC 24V AC 120V AC 240V AC ARP012A6R ARP024A6R ARP120A6R ARP240A6R DIAGRAM 17 12V AC 24V AC 120V AC 240V AC ARP012A2 ARP024A2 ARP120A2 ARP240A2 11 Pin Octal 70170-D 12V AC 24V AC 120V AC 240V AC ARP012A2R ARP024A2R ARP120A2R ARP240A2R DIAGRAM 18 " See Page 58 for Sockets & Accessories. 800-238-7474 www.macromatic.com whats-up@macromatic.com 52 WIRING/SOCKET" AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 1 Switch Applications Application Data & Dimensions Application Data Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz. Transient Protection: 10,000 volts for 20 microseconds Load (Burden): Less than 3VA Indicator LED's: 2 LED's marked LOAD A and LOAD B Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC Optional Selector Switch Settings: ALTERNATE LOCK LOAD A LOCK LOAD B Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations o o o Approvals: o Temperature: -28 to 65 C (-20 to 150 F) File #E109466 File #LR45565 File #E109466 with appropriate socket Dimensions 2.4 (60) All Dimensions in Inches (Millimeters) 2.9 (74) 3.1 (79) 1.7 (43) Typical Installations The loads in the following examples could be pumps, compressors, or air conditioning/refrigeration units: SPDT & DPDT In the off state, the Control Switch is open, the Alternating Relay is in the LOAD A position, and both loads (M1 & M2) are off. When the Control Switch closes, it energizes the first load (M1). The red LED marked “LOAD A” glows. As long as the Control Switch remains closed, M1 remains energized. When the Control Switch opens, the first load (M1) is turned off and the Alternating Relay toggles to the LOAD B position. When the Control Switch closes again, it energizes the second load (M2). The red LED marked “LOAD B” glows. When the Control Switch opens, the second load (M2) is turned off, the Alternating Relay toggles back to the LOAD A position, and the process can be repeated again. On relays with DPDT contacts, two pilot lights can be used for remote indication of LOAD A or LOAD B status. SPDT DPDT 53 AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 2 Switch (Lead-Lag) Applications DPDT Cross-Wired ! For duplex loads ! Works with 2 Control Switches--LEAD & LAG ! Control voltages of 12, 24, 120 & 240V AC ! Compact plug-in design utilizing industry-standard 8 pin octal socket ! 10A DPDT Cross-Wired Output Configuration for Lead-Lag Switches ! Optional low profile selector switch to lock in one sequence ! 2 LED’s indicate relay status ! with appropriate socket Alternating Relays are used in special applications where the optimization of load usage is required by equalizing the run time of two loads. They are also used where additional capacity is required in case of excess load requirements. This alternating action is initiated by a control switch, such as a float switch, manual switch, timing relay, pressure switch, or other isolated contact. Each time the initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay. The Alternating Relays listed on this page are available in DPDT Cross-Wired output configurations for use with one or two control switches (LEAD & LAG). See "Typical Installations" on Page 55 for more information. For a special version of a DPDT cross-wired unit to work with three control switches (LEAD, LAG & STOP), see page 56. For products with SPDT or DPDT output configurations to be used with one control switch, see Page 52. Each version is available with an optional three position selector switch. This allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the Alternating Relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. The selector switch has a low profile to prevent any accidental changes in status. OUTPUT CONTACTS DPDT CROSSWIRED w/o Selector Switch DPDT CROSSWIRED w/ Selector Switch CONTROL VOLTAGE PRODUCT NUMBER 12V AC 24V AC 120V AC 240V AC ARP012A3 ARP024A3 ARP120A3 ARP240A3 12V AC 24V AC 120V AC 240V AC ARP012A3R ARP024A3R ARP120A3R ARP240A3R WIRING/SOCKET" 8 Pin Octal 70169-D DIAGRAM 19 " See Page 58 for Sockets & Accessories. 800-238-7474 www.macromatic.com whats-up@macromatic.com 54 AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 2 Switch (Lead-Lag) Applications Application Data & Dimensions Application Data Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz. Transient Protection: 10,000 volts for 20 microseconds Load (Burden): Less than 3VA Indicator LED's: 2 LED's marked LOAD A and LOAD B Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC Optional Selector Switch Settings: ALTERNATE LOCK LOAD A LOCK LOAD B Life: Mechanical: 10,000,000 operations Full Load: 100,000 operations o o o Approvals: o Temperature: -28 to 65 C (-20 to 150 F) File #E109466 File #LR45565 File #E109466 with appropriate socket Dimensions 2.4 (60) 2.9 (74) 3.1 (79) 1.7 (43) All Dimensions in Inches (Millimeters) Typical Installations The loads in the following examples could be pumps, compressors, or air conditioning/refrigeration units: DPDT Cross-Wired In the off state, both the Lead Control Switch and the Lag Control Switch are open, the Alternating Relay is in the LOAD A position, and both loads are off. When the Lead Control Switch closes, it energizes the first load (M1). The red LED marked “LOAD A” glows. As long as the Lead Control Switch remains closed, M1 remains energized. If the Lag Control Switch closes, it energizes the second load (M2). When the Lag Control Switch opens, the second load (M2) is turned off. When the Lead Control Switch opens, the first load (M1) is turned off and the Alternating Relay toggles to the LOAD B position. When the Lead Control Switch closes, it turns on the second load (M2). The red LED marked “LOAD B” glows. If the Lag Control Switch closes, it will energize the first load (M1). When the Lag Control Switch opens, the first load (M1) is turned off. When the Lead Control Switch opens, the second load (M2) is turned off, the Alternating Relay toggles back to the LOAD A position, and the process can be repeated again. NOTE: if the Lag Control Switch does not close while the Lead Control Switch is closed, the Alternating Relay will act as a normal unit. 55 AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 3 Switch Applications (Lead-Lag-Stop) Sequence On-Simultaneous OFF ! Works with 3 Control Switches - LEAD, LAG and STOP ! Utilizes Sequence On Simultaneously Off (S.O.S.O.) Operation ! Replaces Separate Components in Duplex Panel, Saving Space and Reducing Labor ! Protects against Failures of Both STOP & LEAD Switches ! Control Voltages of 12, 24, 120 & 240V AC ! Compact Plug-in Design Utilizing Industry-Standard 8 Pin Octal Socket ! Optional low profile selector switch to lock in one sequence ! 2 LED’s indicate relay status ! with appropriate socket Macromatic Alternating Relays for Three Switch Applications offer a number of unique advantages over standard duplex units: # # # # Combines standard DPDT cross-wired Alternating Relay, contactor auxiliary contacts and control relay into one compact & economical product, thus reducing the cost of the panel by saving space, reducing the number of components and minimizing assembly labor. Works with three switches instead of just one or two − LEAD, LAG and STOP. Sequence On - Simultaneous Off (S.O.S.O.) Operation − the two loads are energized sequentially, but remain on together until the STOP switch is opened. Protects against failure of the STOP and LEAD switches − if both switches fail, the two pump motors will be energized simultaneously when the LAG switch is closed. See "Typical Installations" on Page 57 for more information. Alternating Relays from Macromatic are available with an optional three position selector switch. This allows the unit to alternate the two loads as normal, or lock the relay to one load or the other. By locking the Alternating Relay to one load, the other load can be removed for service without rewiring the first load for continuous operation. The selector switch has a low profile to prevent any accidental changes in status. OUTPUT CONTACTS DPDT CROSSWIRED For 3 Switch Operation w/o Selector Switch DPDT CROSSWIRED For 3 Switch Operation w/ Selector Switch CONTROL VOLTAGE PRODUCT NUMBER 12V AC 24V AC 120V AC 240V AC ARP012A8 ARP024A8 ARP120A8 ARP240A8 12V AC 24V AC 120V AC 240V AC ARP012A8R ARP024A8R ARP120A8R ARP240A8R WIRING/SOCKET" 8 Pin Octal 70169-D DIAGRAM 58 " See Page 58 for Sockets & Accessories. 800-238-7474 www.macromatic.com whats-up@macromatic.com 56 AL TERNA TING RELA YS ALTERNA TERNATING RELAYS For 3 Switch Applications Application Data & Dimensions Dimensions Application Data Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz. Load (Burden): Less than 3VA Output Contacts: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC 2.4 (60) Life: Mechanical: 10,000,000 operations Full Load: 150,000 operations Temperature: -28o to 65oC (-20o to 150oF) Transient Protection: 10,000 volts for 20 microseconds 2.9 (74) 1.7 (43) 3.1 (79) Indicator LED's: 2 LED's marked LOAD A and LOAD B Optional Selector Switch Settings: ALTERNATE LOCK LOAD A LOCK LOAD B Approvals: All Dimensions in Inches (Millimeters) with appropriate socket File #E109466 File #E109466 Typical Installations DPDT Cross-Wired for Three Switch Applications In the OFF state, all three switches are open, the Alternating Relay is in the LOAD A position, and both loads are off. No action happens with the Alternating Relay or either load when the STOP Switch closes. When the LEAD Switch closes, Load #1 (M1) turns on. When the LAG Switch closes, Load #2 (M2) turns on. Both loads remain on as long as all three switches are closed. When the LAG Switch opens, Load #2 (M2) remains on because the STOP Switch is still closed. When the LEAD Switch opens, Load #1 (M1) remains on because the STOP Switch is still closed. When the STOP Switch opens, both Load #1 (M1) and Load #2 (M2) are turned off simultaneously. The Alternating Relay toggles to the LOAD B position. The entire cycle is then repeated, but with Load #2 (M2) energized first followed by Load #1 (M1). This type of operation is known as “Sequence On Simultaneously Off (S.O.S.O.)”-the two loads are energized sequentially, but remain on together until the STOP switch is opened. If both the STOP Switch and LEAD Switch fail to close and turn on the first load, both loads will be turned on simultaneously when the LAG Switch is closed. 57 SOCKETS & ACCESSORIES Sockets Product Number 70169-D * Product Number 70170-D Product Number 70171-D Description 8 Pin Octal 11 Pin Octal 11 Pin Spade (Blade) Ratings 10A @ 600V * 10A @ 300V 10A @ 300V Mounting 35MM DIN Rail / Direct Panel 35MM DIN Rail / Direct Panel 35MM DIN Rail / Direct Panel Wire/ Terminations 1 or 2 #12-22 / Pressure Wire Clamps 1 or 2 #12-22 / Pressure Wire Clamps 1 or 2 #12-22 / Pressure Wire Clamps Approvals Dimensions All Dimensions in Inches (Millimeters) * Plug-in Three-Phase Monitor Relays require a 600V-rated socket when used on system voltages greater than 300V. Other Accessories Hold Down Spring Product Number 70166 DIN Mounting Track (3 FT. Section) Product Number 70100 End Clamp Product Number 70200 58 A t Macromatic, we are committed to providing you with the right product, at the right time and at the right price. Alternating Relays STANDARD PRODUCTS ! ! ! ! ! Time Delay Relays Alternating Relays Phase Monitoring Relays Voltage Monitoring Relays Current Monitor Relays C USTOM DESIGNS ! ! Time Delay Relays ! Save money with a dedicated design to fit your application Proprietary design protection offered Agency approvals available TECHNICAL S UPPORT ! Dedicated engineering team One-on-one assistance Application selection help Technical troubleshooting aid ! Toll free help line ! ! ! C USTOMER S ERVICE ! Phase Monitor Relays ! ! ! ! Total Quality Program responsive to your needs Short lead times on small quantity orders Never a charge for expedited delivery Local support through distributors & sales representatives No minimum orders on standard products Voltage Monitor Relays For Details Contact us at 800-238-7474 ! 262-781-3366 FAX 262-781-4433 www.macromatic.com whats-up@macromatic.com Current Monitor Relays The Right Product The Right Time The Right Price Macromatic Controls W134 N5345 Campbell Dr Menomonee Falls, WI 53051 800-238-7474- ! 262-781-3366 ! Fax 262-781-4433 Web: www.macromatic.com ! Email: whats-up@macromatic.com
70170-D 价格&库存

很抱歉,暂时无法提供与“70170-D”相匹配的价格&库存,您可以联系我们找货

免费人工找货