Industrial Control &
Monitoring Products
Alternating Relays
Time Delay Relays
Phase Monitor Relays
Voltage Monitor Relays
Current Monitor Relays
Your Choice for Industrial Controls
For 30 years, Macromatic has been producing industrial control & monitoring products. All are engineered and
manufactured in our U.S.-based facility in Menomonee Falls, Wisconsin (a Milwaukee suburb), utilizing a timeproven quality system to produce products that consistently meet your requirements for function, availability &
value.
Who Uses Our Controls?
A wide variety of challenges can be met
by using our products. Our customer
base includes OEM’s who specify
Macromatic controls in their equipment,
and end users who count on Macromatic
precision and reliability for their own
applications. Our products are used in a
variety of industries such as machine
tool, automotive, material handling, pulp
& paper, food & beverage,
transportation, communications, water/
wastewater and HVAC, among many.
Where to Buy?
We are pleased to offer our complete
line of products in the United States and
Canada through a network of Preferred Macromatic
Distributors. We have partners with national, regional
and local presence who stock and sell our products.
Call us or visit us on the web to locate a distributor or
sales representative near you.
Need Technical Help? Have Special Applications?
Do you need help selecting or applying one of our
products? Don’t quite know what you need? Our
team of engineers and technical advisors is available
to help you address your specific needs. Whether by
helping you decide which time delay relay function is
required in your application or working with you on
designing custom-engineered solutions for your
particular need, we have the experience to help you
one-on-one. Don’t hesitate to call us to discuss your
particular application.
Why Choose Macromatic Controls?
Long known for their precision and reliability,
Macromatic products are increasingly the choice of
industrial design engineers for use in new equipment
and are preferred by maintenance personnel as
quality replacements in existing applications. We test
each product twice before it is shipped, and all
products have an extensive warranty period longer
2
than most other manufacturers (contact Macromatic
for further details). Most standard and custom design
products are UL recognized or listed and CSA
approved. We have obtained UL Listing on our plugin products when used with our sockets. Many
products now carry the CE Mark.
What You Need, When You Need It
Don’t wait for something you need now. Macromatic
offers prompt delivery of standard products and can
even deliver many non-standard orders within seven
to ten days, all without any special expediting fees
charged by many manufacturers. We are dedicated
to being responsive, and that means you get what you
need when you need it, not weeks or months from
now. Contact us or one of our Preferred Distributors
or Sales Representatives and we will provide you with
an on-time solution.
Want to Learn More?
You can reach us at 800-238-7474 or e-mail us at
whats-up@macromatic.com. Our customer service
and technical assistance people are ready to help with
your questions or special needs. Or you can visit us
at www.macromatic.com.
Product Index
Index by Product Number .................................................................................................
4
Phase Monitor Relays
Product Summary .........................................................................................................
PCP Series Phase Reversal .........................................................................................
PLP Series Phase Loss & Phase Reversal ..................................................................
PAP Series Phase Loss, Phase Reversal & Undervoltage ...........................................
PMP Series Phase Loss, Phase Reversal, Phase Unbalance,
Undervoltage & Overvoltage ..............................................................................
PMD Series Phase Loss, Phase Reversal, Phase Unbalance,
Undervoltage & Overvoltage ..............................................................................
14-15
Current Monitor Relays NEW
Product Summary .........................................................................................................
CM Series Standard ......................................................................................................
CO Series Overcurrent .................................................................................................
CU Series Undercurrent ................................................................................................
17
18-19
20-21
22-23
5
6-7
8-9
10-11
12-13
Voltage Monitor Relays NEW
Product Summary .........................................................................................................
24
VM Series Over/Under Voltage (Fixed Time Delay on Drop-Out) .................................. 25, 27
VA Series Over/Under Voltage (Adjustable Time Delay on Drop-Out) ........................... 26-27
VW Series Voltage Band (Window) ............................................................................... 28-29
Time Delay Relays
Product Summary .........................................................................................................
Definition of Timing Functions ........................................................................................
TR-5 Series Non-Programmable DPDT ........................................................................
TR-5 Series Non-Programmable 8 Pin SPDT ...............................................................
TR-6 Series Time Ranger Programmable Multi-Range ................................................
SS-6 & -8 Series Compact Non-Programmable ...........................................................
SS-4 Series Non-Programmable with Quick Connect Terminals ..................................
TD-7 Series Time Ranger Digital-Set Programmable ...................................................
981 Series Time Ranger III Digital-Set Multi-Function Multi-Range ...............................
Standard Modifications ..................................................................................................
30-31
32-33
34-37
38-39
40-43
44
45
46-47
48-49
50-51
Alternating Relays
For 1 Switch Applications (SPDT& DPDT) ...................................................................
For 2 Switch Applications (DPDT Cross-Wired) ...........................................................
For 3 Switch Applications ..............................................................................................
52-53
54-55
56-57
Sockets & Accessories ..................................................................................................... 16 & 58
Since we continuously strive to improve and update our product offering, specifications are subject to change without notice.
“Macromatic” & “Time Ranger” are Registered Tradenames of Macromatic Controls LLC
3
Index By Product Number
Product *
70100
70166
70169-D
70170-D
70171-D
70200
70300
70310
70320
9816U1
ARP012A2
ARP012A2R
ARP012A3
ARP012A3R
ARP012A6
ARP012A6R
ARP012A8
ARP012A8R
ARP024A2
ARP024A2R
ARP024A3
ARP024A3R
ARP024A6
ARP024A6R
ARP024A8
ARP024A8R
ARP120A2
ARP120A2R
ARP120A3
ARP120A3R
ARP120A6
ARP120A6R
ARP120A8
ARP120A8R
ARP240A2
ARP240A2R
ARP240A3
ARP240A3R
ARP240A6
ARP240A6R
ARP240A8
ARP240A8R
CMKP01A22
CMKP01A28
CMKP01A62
CMKP01A68
CMKP05A22
CMKP05A28
CMKP05A62
CMKP05A68
CMKP10A22
CMKP10A28
CMKP10A62
CMKP10A68
CMP01A22
CMP01A28
CMP01A62
CMP01A68
CMP05A22
CMP05A28
CMP05A62
CMP05A68
CMP10A22
CMP10A28
CMP10A62
CMP10A68
COKP01A22
COKP01A28
COKP01A62
COKP01A68
COKP05A22
Page
16 & 58
16 & 58
16 & 58
16 & 58
16 & 58
16 & 58
48
48
48
48
52
52
54
54
52
52
56
56
52
52
54
54
52
52
56
56
52
52
54
54
52
52
56
56
52
52
54
54
52
52
56
56
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
20
20
20
20
20
Product *
COKP05A28
COKP05A62
COKP05A68
COKP10A22
COKP10A28
COKP10A62
COKP10A68
COP01A22
COP01A28
COP01A62
COP01A68
COP05A22
COP05A28
COP05A62
COP05A68
COP10A22
COP10A28
COP10A62
COP10A68
CUP01A22
CUP01A28
CUP01A62
CUP01A68
CUP05A22
CUP05A28
CUP05A62
CUP05A68
CUP10A22
CUP10A28
CUP10A62
CUP10A68
PAP120
PAP208
PAP240
PAP400
PAP480
PCP1
PCP2
PLP120
PLP208
PLP240
PLP400
PLP480
PMD120
PMD208
PMD240
PMD400
PMD480
PMD600
PMDU
PMP120
PMP208
PMP240
PMP480
PMPU
SS-3062-xx
SS-3066-xx
SS-3068-xx
SS-3162-xx
SS-3166-xx
SS-3168-xx
SS-3262-xx
SS-3266-xx
SS-3268-xx
SS-3362-xx
SS-3366-xx
SS-3368-xx
SS-3562-xx
SS-3566-xx
SS-3568-xx
SS-40222-xx
Page
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
20
22
22
22
22
22
22
22
22
22
22
22
22
10
10
10
10
10
6
6
8
8
8
8
8
14
**
**
**
**
14
14
12
**
**
**
12
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
45
Product *
SS-40228-xx
SS-41622-xx
SS-41628-xx
SS-6262-xx
SS-6266-xx
SS-6268-xx
SS-70166
SS-8062-xx
SS-8066-xx
SS-8068-xx
SS-8162-xx
SS-8166-xx
SS-8168-xx
SS-8562-xx
SS-8566-xx
SS-8568-xx
SS-8762-xx
SS-8766-xx
SS-8768-xx
TD-70221
TD-70222
TD-70226
TD-70228
TD-70521
TD-70522
TD-70526
TD-70528
TD-70821
TD-70822
TD-70826
TD-70828
TD-71521
TD-71522
TD-71526
TD-71528
TD-71621
TD-71622
TD-71626
TD-71628
TD-78121
TD-78122
TD-78126
TD-78128
TR-50221-xx
TR-50222-xx
TR-50226-xx
TR-50228-xx
TR-50521-xx
TR-50522-xx
TR-50526-xx
TR-50528-xx
TR-50821-xx
TR-50822-xx
TR-50826-xx
TR-50828-xx
TR-51321-xx
TR-51322-xx
TR-51326-xx
TR-51328-xx
TR-51361-xx
TR-51362-xx
TR-51366-xx
TR-51368-xx
TR-51521-xx
TR-51522-xx
TR-51526-xx
TR-51528-xx
TR-51561-xx
TR-51562-xx
TR-51566-xx
TR-51568-xx
Page
45
45
45
44
44
44
***
44
44
44
**
**
**
44
44
44
44
44
44
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
46
34
34
34
34
34
34
34
34
34
34
34
34
35
35
35
35
38
38
38
38
35
35
35
35
38
38
38
38
* The “-xx” suffix denotes the time range for non-programmable time delay relays.
4
Product *
TR-51621-xx
TR-51622-xx
TR-51626-xx
TR-51628-xx
TR-51661-xx
TR-51662-xx
TR-51666-xx
TR-51668-xx
TR-51721-xx
TR-51722-xx
TR-51726-xx
TR-51728-xx
TR-51761-xx
TR-51762-xx
TR-51766-xx
TR-51768-xx
TR-51821-xx
TR-51822-xx
TR-51826-xx
TR-51828-xx
TR-51861-xx
TR-51862-xx
TR-51866-xx
TR-51868-xx
TR-51921-xx
TR-51922-xx
TR-51926-xx
TR-51928-xx
TR-51961-xx
TR-51962-xx
TR-51966-xx
TR-51968-xx
TR-53121-xx
TR-53122-xx
TR-53126-xx
TR-53128-xx
TR-55121-xx
TR-55122-xx
TR-55126-xx
TR-55128-xx
TR-56121-xx
TR-56122-xx
TR-56126-xx
TR-56128-xx
TR-56521-xx
TR-56522-xx
TR-56526-xx
TR-56528-xx
TR-60221
TR-60222
TR-60226
TR-60228
TR-60521
TR-60522
TR-60526
TR-60528
TR-60821
TR-60822
TR-60826
TR-60828
TR-61321
TR-61322
TR-61326
TR-61328
TR-61521
TR-61522
TR-61526
TR-61528
TR-61621
TR-61622
TR-61626
**
Page
35
35
35
35
38
38
38
38
35
35
35
35
38
38
38
38
35
35
35
35
38
38
38
38
35
35
35
35
38
38
38
38
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
36
40
40
40
40
40
40
40
40
40
40
40
40
41
41
41
41
41
41
41
41
41
41
41
Product *
TR-61628
TR-61721
TR-61722
TR-61726
TR-61728
TR-61821
TR-61822
TR-61826
TR-61828
TR-61921
TR-61922
TR-61926
TR-61928
TR-63121
TR-63122
TR-63126
TR-63128
TR-65121
TR-65122
TR-65126
TR-65128
TR-66121
TR-66122
TR-66126
TR-66128
TR-66521
TR-66522
TR-66526
TR-66528
TR-68129
TR-68169
VAKP012D
VAKP024A
VAKP024D
VAKP048D
VAKP110D
VAKP120A
VAP012D
VAP024A
VAP024D
VAP048D
VAP110D
VAP120A
VMKP012D
VMKP024A
VMKP024D
VMKP048D
VMKP110D
VMKP120A
VMP012D
VMP024A
VMP024D
VMP048D
VMP110D
VMP120A
VWKP012D
VWKP024A
VWKP024D
VWKP048D
VWKP110D
VWKP120A
VWP012D
VWP024A
VWP024D
VWP048D
VWP110D
VWP120A
Page
41
41
41
41
41
41
41
41
41
41
41
41
41
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
42
**
**
26
26
26
26
26
26
26
26
26
26
26
26
25
25
25
25
25
25
25
25
25
25
25
25
28
28
28
28
28
28
28
28
28
28
28
28
Contact Macromatic for more information.
PHASE MONITOR RELA
YS
RELAYS
Product Summar
y
Summary
Phase Monitor Relays provide protection against premature equipment failure caused by voltage faults on 3 Phase
systems. All Macromatic Phase Monitor Relays are designed to be compatible with most Wye or Delta systems. In
Wye systems, a connection to a neutral is not required. Phase Monitor Relays protect against single phasing regardless of any regenerative voltages.
The Reference Guide below provides general information on the different versions of Phase Monitor Relays offered by
Macromatic (see Product Selection on the following pages for further details):
Series
Mounting
Style
PCP
Plug-in *
PLP
Plug-in *
PAP
Plug-in *
PMP
Plug-in *
PMD
Surface
Phase
Loss
Phase
Reversal
!
!
!
!
!
!
!
!
!
Phase
Unbalance
Under
Voltage
Over
Voltage
Time Delay on
Undervoltage
Approvals *
See
Page
6
8
!
!
! (adj.)
! (adj.)
! (adj.)
! (fixed)
! (fixed)
50ms fixed
10
0.1 - 20 sec.
12
0.1 - 20 sec.
14
* In addition to the above approvals, all Plug-in Products are also UL Listed when used with the appropriate Macromatic socket.
Protection
Typical Connections
Depending on the unit selected, it will protect three phase
equipment against:
! phase loss - total loss of one or more of the three
phases. Also known as "single phasing." Typically
caused by a blown fuse, broken wire, or worn contact. This condition would result in a motor drawing
locked rotor current during start-up. In addition, a
three phase motor will continue to run after losing a
phase, resulting in possible motor burn-out.
! phase reversal - reversing any two of the three
phases will cause a three phase motor to run in the
opposite direction. This may cause damage to driven
machinery or injury to personnel. The condition
usually occurs as a result of mistakes made during
routine maintenance or when modifications are made
to the circuit.
! phase unbalance - unbalance of a three phase
system occurs when single phase loads are connected such that one or two of the lines (phases)
carry more or less of the load. This could cause
motors to run at temperatures above published
ratings.
! undervoltage - when voltage in all three lines of a
three phase system drop simultaneously.
! overvoltage - when voltage in all three lines of a
three phase system increase simultaneously.
Line Side Monitoring
With the relay connected before the motor starter, the motor
can be started in the reverse direction. However, the motor is
unprotected against phase failures between the relay and the
motor.
Load Side Monitoring
With the relay connected directly to the motor, the total feed
lines are monitored. This connection should not be used with
reversing motors.
5
PHASE MONITOR RELA
YS
RELAYS
Phase Reversal Only
PC Series Plug-in
!
Protects against phase
reversal
!
One version works on 208480V 3 Phase Systems
!
LED indicates both normal
and fault conditions
!
Compact plug-in case
utilizing industry-standard
8 pin octal socket
!
10A SPDT output contacts
!
(with appropriate socket)
The PC Series Phase Monitor Relays provide protection against phase reversal in
a compact plug-in design. One version will work on any 3 phase system from 208V
to 480V (a separate 120V-only version is also available). These devices are
designed to be compatible with most Wye or Delta systems. In Wye systems, a
connection to a neutral is not required.
The relay is energized and the LED on when the sequence is correct. Any fault will
de-energize the relay and turn off the LED. Re-energization is automatic upon
correction of the fault condition.
MOUNTING
STYLE
NOMINAL
VOLTAGE
50/60 Hz
UNDERVOLTAGE
RANGE
PRODUCT
NUMBER
WIRING/
SOCKET"
"
Plug-in
120V
n/a
PCP1
8 Pin Octal
70169-D
208-480V
n/a
PCP2 *
DIAGRAM 23
* Requires a 600V-rated socket when used on system voltages greater than 300V.
" See Page 16 for Sockets & Accessories
800-238-7474
www.macromatic.com
whats-up@macromatic.com
6
PHASE MONITOR RELA
YS
RELAYS
Phase Reversal Only
PC Series Plug-in
Application Data & Dimensions
Application Data
Phase Reversal:
Unit trips if sequence of the three phases is anything other than A-B-C.
Output Contacts:
10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)
Life:
Full Load: 100,000 operations
Response Times:
Operate: 50ms
Release: 50ms
Load (Burden):
3VA
Temperature:
-28o to 65oC (-20o to 150oF)
Transient Protection:
10,000 volts for 20 microseconds
Mounting:
Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic
Product Number 70169-D--see Page 16).
Indicator LED:
Red LED on when all conditions are normal, and off when a fault condition has occurred.
Reset:
Automatic upon correction of fault
Approvals:
When used with Macromatic
socket 70169-D rated 600V
File #E109466
File #E109466
Dimensions
2.4 (60)
2.9
(74)
3.0
(76)
1.7
(43)
All Dimensions in
Inches (Millimeters)
7
PHASE MONITOR RELA
YS
RELAYS
Phase Loss & Phase Reversal
PL Series Plug-in
!
Protects against phase loss
& phase reversal
!
LED indicates both normal
and fault conditions
!
Compact plug-in case
utilizing industry-standard
8 pin octal socket
!
10A SPDT output contacts
!
(with appropriate socket)
The PL Series Phase Monitor Relays provide protection against phase loss &
phase reversal in a compact plug-in design. These devices are designed to be
compatible with most Wye or Delta systems. In Wye systems, a connection to a
neutral is not required. Phase Monitor Relays protect against single phasing
regardless of any regenerative voltages.
The relay is energized and the LED on when all three phases are present and in
the correct sequence. Any fault will instantaneously de-energize the relay and turn
off the LED. Re-energization is automatic upon correction of the fault condition.
MOUNTING
STYLE
NOMINAL
VOLTAGE
50/60 Hz
UNDERVOLTAGE
RANGE
PRODUCT
NUMBER
WIRING/
"
SOCKET"
Plug-in
120V
n/a
PLP120
8 Pin Octal
70169-D
208V
n/a
PLP208
240V
n/a
PLP240
400V
n/a
PLP400 *
480V
n/a
PLP480 *
DIAGRAM 23
* Requires a 600V-rated socket when used on system voltages greater than 300V.
" See Page 16 for Sockets & Accessories
800-238-7474
www.macromatic.com
whats-up@macromatic.com
8
PHASE MONITOR RELA
YS
RELAYS
Phase Loss & Phase Reversal
PL Series Plug-in
Application Data & Dimensions
Application Data
Phase Loss:
Unit trips on loss of any Phase A, B or C
Phase Reversal:
Unit trips if sequence of the three phases is anything other than A-B-C.
Output Contacts:
10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)
Life:
Full Load: 100,000 operations
Response Times:
Operate: 50ms
Release: 50ms
Load (Burden):
3VA
Temperature:
-28o to 65oC (-20o to 150oF)
Transient Protection:
10,000 volts for 20 microseconds
Mounting:
Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic
Product Number 70169-D--see Page 16).
Indicator LED:
Red LED on when all conditions are normal, and off when a fault condition has occurred.
Reset:
Automatic upon correction of fault
Approvals:
When used with Macromatic
socket 70169-D rated 600V
File #E109466
File #E109466
Dimensions
2.4 (60)
2.9
(74)
3.0
(76)
1.7
(43)
All Dimensions in
Inches (Millimeters)
9
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal & Under
voltage
Undervoltage
PA Series Plug-in
!
Protects against phase loss,
phase reversal & undervoltage
!
Undervoltage setting is
adjustable from 75-95% of
nominal
!
LED indicates both normal
and fault conditions
!
Compact plug-in case
utilizing industry-standard
8 pin octal socket
!
10A SPDT output contacts
!
(with appropriate socket)
The PA Series Phase Monitor Relays provide protection against phase loss, phase
reversal & undervoltage in a compact plug-in design. These devices are designed
to be compatible with most Wye or Delta systems. In Wye systems, a connection
to a neutral is not required. Phase Monitor Relays protect against single phasing
regardless of any regenerative voltages.
The relay is energized and the LED on when all three phase are present in the
correct sequence at a voltage level above the undervoltage setting. The undervoltage drop-out can be set at 75-95% of operating voltage. Any fault will instantaneously de-energize the relay and turn off the LED. Re-energization is automatic
upon correction of the fault condition.
MOUNTING
STYLE
NOMINAL
VOLTAGE
60 Hz
UNDERVOLTAGE
RANGE
PRODUCT
NUMBER
WIRING/
SOCKET"
"
Plug-in
120V
90-115V
PAP120
8 Pin Octal
70169-D
208V
156-198V
PAP208
240V
180-230V
PAP240
400V
300-380V
PAP400 *
480V
360-460V
PAP480 *
DIAGRAM 23
* Requires a 600V-rated socket when used on system voltages greater than 300V.
" See Page 16 for Sockets & Accessories
800-238-7474
www.macromatic.com
whats-up@macromatic.com
10
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal & Under
voltage
Undervoltage
PA Series Plug-in
Application Data & Dimensions
Application Data
Phase Loss:
Unit trips on loss of any Phase A, B or C
Phase Reversal:
Unit trips if sequence of the three phases is anything other than A-B-C.
Undervoltage:
Adjustable over a range per product selection table. Unit trips when the average of all three lines is less than the adjusted set
point.
Output Contacts:
10A SPDT @ 240V AC, 1/3HP @ 240V AC (N.O.), 1/6HP @ 240V AC (N.C.)
Life:
Full Load: 100,000 operations
Response Times:
Operate: 50ms
Release: 50ms
Load (Burden):
3VA
Temperature:
-28o to 65oC (-20o to 150oF)
Transient Protection:
10,000 volts for 20 microseconds
Mounting:
Uses an 8 pin octal socket. Requires a 600V-rated socket when used on system voltages greater than 300V (Macromatic
Product Number 70169-D--see Page 16).
Indicator LED:
Red LED on when all conditions are normal, and off when a fault condition has occurred.
Reset:
Automatic upon correction of fault
Approvals:
When used with Macromatic
socket 70169-D rated 600V
File #E109466
File #E109466
Dimensions
2.4 (60)
2.9
(74)
3.5
(89)
1.7
(43)
All Dimensions in
Inches (Millimeters)
11
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal, Phase
Unbalance, and Under/Over V
oltage
Voltage
PMP Series Plug-in
!
Universal voltage range of
208-480V on PMPU provides
the flexibility to cover a
variety of applications
!
Protects against phase loss,
phase reversal, phase
unbalance, undervoltage and
overvoltage
!
Variety of user-selectable
and adjustable settings for
the ultimate in three-phase
protection
!
Automatic or Manual Reset
!
Multi-Color LED indicates
normal condition and defines
fault to simplify troubleshooting
!
Compact plug-in case
utilizing industry-standard 8
pin octal socket
!
10A SPDT output contacts
The PMP Series Phase Monitor Relays utilize a microprocessor-based design to provide
protection against phase loss, phase reversal, phase unbalance, undervoltage and
overvoltage. The PMPU is a universal voltage product that works on any three-phase
system voltage from 208-480V (a separate 120V version is available). These devices are
designed to be compatible with most Wye or Delta systems. In Wye systems, a connection
to a neutral is not required. PMP Series products protect against unbalanced voltages or
single phasing regardless of any regenerative voltages.
The relay is energized when the phase sequence and all voltages are correct. Any one of
five fault conditions will de-energize the relay. As standard, re-energization is automatic
upon correction of the fault condition. Manual reset is available if a momentary N.C. switch
is wired to the appropriate terminals. A multi-color LED indicates normal condition and also
provides specific fault indication to simplify troubleshooting.
The PMP Series offers a variety of user-adjustable settings. The percent phase unbalance
is adjustable from 2-10%, and also has a “Disable” setting for those applications where
poor voltage conditions could cause nuisance tripping. The undervoltage drop-out can be
set at 80-95% of operating voltage (overvoltage setting is fixed at 110% of nominal). The
adjustable time delay drop-out on undervoltage (0.1-20 seconds) eliminates nuisance
tripping caused by momentary voltage fluctuations. There is also an adjustable time delay
(1-300 seconds) on both power up and restart after a fault has been cleared.
!
MOUNTING
STYLE
OPERATING
VOLTAGE
50/60 Hz
PRODUCT
NUMBER
Plug-in
120V
PMP120
208-480V
PMPU *
(with appropriate socket)
WIRING/SOCKET "
8 Pin Octal
70169-D
DIAGRAM 104
* Requires a 600V-rated socket when used on system voltages greater than 300V.
" See Page 16 for Sockets & Accessories
800-238-7474
www.macromatic.com
whats-up@macromatic.com
12
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal, Phase
Unbalance, and Under/Over V
oltage
Voltage
PMP Series Plug-in
Application Data & Dimensions
Application Data
Phase Loss:
Unit trips on loss of any Phase A, B or C.
Hysteresis: 2 - 3%
Load (Burden): Less than 3VA
Phase Reversal:
Unit trips if rotation (sequence) of the three phases is anything
other than A-B-C.
Undervoltage:
Adjustable from 80-95% of nominal voltage. Unit trips when the
average of all three lines is less than the adjusted set point for
a period longer than the adjustable time delay drop-out.
Overvoltage:
Fixed at 110% of nominal voltage. Unit trips when the average
of all three lines is greater than the fixed set point for a period
longer than the time delay drop-out.
Temperature: -28o to 65oC (-20o to 150oF)
Mounting:
Uses an 8 pin octal socket. Requires a 600V-rated socket
when used on system voltages greater than 300V (Macromatic
Product Number 70169-D--see Page 16).
Indicator LED:
LED Status
Indicator
Green Steady
Normal / Relay ON
Green Flashing
Power Up / Restart Delay
Phase Unbalance:
Adjustable from 2 - 10% unbalance. Unit trips when any one of
the three lines deviates from the average of all three lines by
more than the adjusted set point . There is also a “Disable”
setting adjustment that will turn off the Phase Unbalance
Protection if nuisance tripping is a problem.
Red Steady
Unbalance
Red Flashing
Undervoltage / Overvoltage
Amber Steady
Reversal
Amber Flashing
Output Contacts:
SPDT: 10A Resistive @ 240V AC/30V DC,
1/2HP @ 120/240V AC
Green / Red Alternating
Loss
Undervoltage / Overvoltage
Trip Pending
Nominal Voltage Set Error
Red / Amber Alternating *
* Applies to 208-480V units only.
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Response Times:
Power Up & Restart After Fault:
Drop-out Due to Fault:
Phase Loss & Reversal
Phase Unbalance
Undervoltage
Overvoltage
1 - 300 seconds adjustable
100ms fixed
2 seconds fixed
0.1 - 20 seconds adjustable
Fixed Time Based on Inverse
Time Curve
Reset:
As standard, reset is automatic upon correction of fault. When
a momentary-contact N.C. switch is wired across the Manual
Reset terminals (5 & 6), the unit switches to manual reset
mode and remote manual reset is available.
Approvals:
Low Voltage & EMC Directives
EN60947-1, EN60947-5-1
File #E109466
When used with Macromatic
socket 70169-D rated 600V
File #E109466
Dimensions
2.4
(60)
All Dimensions in
Inches (Millimeters)
2.9
(74)
1.7
(43)
3.0
(77)
13
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal, Phase
Unbalance, and Under/Over V
oltage
Voltage
PMD Series Surface-Mount
!
Universal voltage range of
208-480V on PMDU provides the flexibility to cover a
variety of applications
!
Protects against phase loss,
phase reversal, phase
unbalance, undervoltage and
overvoltage
!
Variety of user-selectable
and adjustable settings for
the ultimate in three-phase
protection
!
Automatic or Manual Reset
!
Multi-Color LED indicates
normal condition and defines
fault to simplify troubleshooting
!
45mm DIN-style surfacemount case
!
10A SPDT & SPNC output
contacts
The PMD Series Phase Monitor Relays utilize a microprocessor-based design to provide
protection against phase loss, phase reversal, phase unbalance, undervoltage and
overvoltage. The PMDU is a universal voltage product that works on any three-phase
system voltage from 208-480V (separate 120V & 600V versions are available). These
devices are designed to be compatible with most Wye or Delta systems. In Wye systems,
a connection to a neutral is not required. PMD Series products protect against unbalanced
voltages or single phasing regardless of any regenerative voltages.
The relay is energized when the phase sequence and all voltages are correct. Any one of
five fault conditions will de-energize the relay. As standard, re-energization is automatic
upon correction of the fault condition. Manual reset is available if a momentary N.C. switch
is wired to the appropriate terminals. A multi-color LED indicates normal condition and also
provides specific fault indication to simplify troubleshooting.
The PMD Series offers a variety of user-adjustable settings. The percent phase unbalance
is adjustable from 2-10%, and also has a “Disable” setting for those applications where
poor voltage conditions could cause nuisance tripping. The undervoltage drop-out can be
set at 80-95% of operating voltage (overvoltage setting is fixed at 110% of nominal). The
adjustable time delay drop-out on undervoltage (0.1-20 seconds) eliminates nuisance
tripping caused by momentary voltage fluctuations. There is also an adjustable time delay
(1-300 seconds) on both power up and restart after a fault has been cleared.
!
MOUNTING
STYLE
OPERATING
VOLTAGE
50/60 Hz
PRODUCT
NUMBER !
Surface-Mount
120V
PMD120
208-480V
600V
WIRING "
PMDU
PMD600
DIAGRAM 105
! To order PMD units with a second N.O. contact instead of the N.C. (terminals 21-22),
800-238-7474
www.macromatic.com
whats-up@macromatic.com
14
add a suffix “-A1” to the Product Number, i.e., PMDU-A1. To order PMD units with
DPDT output contacts instead of one SPDT and one SPNC, but with no manual reset
feature, add a suffix “-A2” to the Product Number, i.e., PMDU-A2.
" See Page 16 for Accessories
PHASE MONITOR RELA
YS
RELAYS
Phase Loss, Phase Reversal, Phase
Unbalance, and Under/Over V
oltage
Voltage
PMD Series Surface-Mount
Application Data & Dimensions
Application Data
Phase Loss:
Unit trips on loss of any Phase A, B or C.
Hysteresis: 2 - 3%
Load (burden): Less than 3VA
Phase Reversal:
Unit trips if rotation (sequence) of the three phases is anything
other than A-B-C.
Undervoltage:
Adjustable from 80-95% of nominal voltage. Unit trips when the
average of all three lines is less than the adjusted set point for
a period longer than the adjustable time delay drop-out.
Overvoltage:
Fixed at 110% of nominal voltage. Unit trips when the average
of all three lines is greater than the fixed set point for a period
longer than the time delay drop-out.
Phase Unbalance:
Adjustable from 2 - 10% unbalance. Unit trips when any one of
the three lines deviates from the average of all three lines by
more than the adjusted set point . There is also a “Disable”
setting adjustment that will turn off the Phase Unbalance
Protection if nuisance tripping is a problem.
Temperature: -28o to 65oC (-20o to 150oF)
Mounting:
Does not require a socket. Can either be mounted directly on
35mm DIN track with no additional parts or to a back-panel
with two screws.
Indicator LED:
LED Status
Green Steady
Normal / Relay ON
Green Flashing
Power Up / Restart Delay
Red Steady
Unbalance
Red Flashing
Undervoltage / Overvoltage
Amber Steady
Reversal
Amber Flashing
Loss
Undervoltage / Overvoltage
Trip Pending
Nominal Voltage Set Error
Output Contacts: SPDT & SPNC
N.O.: 10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC
N.C.: 10A Resistive @ 240V AC/30V DC, 1/3HP @ 240 VAC
Green / Red Alternating
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
* Applies to 208-480V units only.
Response Times:
Power Up & Restart After Fault:
Drop-out Due to Fault:
Phase Loss & Reversal
Phase Unbalance
Undervoltage
Overvoltage
1 - 300 seconds adjustable
100ms fixed
2 seconds fixed
0.1 - 20 seconds adjustable
Fixed Time Based on Inverse
Time Curve
Indicator
Red / Amber Alternating *
Reset:
As standard, reset is automatic upon correction of fault. When
a momentary-contact N.C. switch is wired across the Manual
Reset terminals (5 & 6), the unit switches to manual reset
mode and remote manual reset is available.
Approvals:
Low Voltage & EMC Directives
EN60947-1, EN60947-5-1
File #E109466
Dimensions
TWO 0.2 (5) MOUNTING HOLES
2.7 2.4
(70) (60)
All Dimensions in
Inches (Millimeters)
1.4 (35)
1.8 (45)
4.3 (110)
4.4 (112)
15
SOCKETS & ACCESSORIES
Sockets
Product Number
70169-D *
Product Number
70170-D
Product Number
70171-D
Description
8 Pin Octal
11 Pin Octal
11 Pin Spade (Blade)
Ratings
10A @ 600V *
10A @ 300V
10A @ 300V
Mounting
35MM DIN Rail /
Direct Panel
35MM DIN Rail /
Direct Panel
35MM DIN Rail /
Direct Panel
Wire/
Terminations
1 or 2 #12-22 /
Pressure Wire Clamps
1 or 2 #12-22 /
Pressure Wire Clamps
1 or 2 #12-22 /
Pressure Wire Clamps
Approvals
Dimensions
All Dimensions in
Inches (Millimeters)
*
Plug-in Three-Phase Monitor Relays require a 600V-rated socket when used on system voltages greater than 300V.
Other Accessories
Hold Down Spring
Product Number 70166
35mm DIN Mounting Track (3 FT. Section)
Product Number 70100
End Clamp
Product Number 70200
16
CURRENT MONITOR RELA
YS
RELAYS
Product Summar
y
Summary
Current Monitor Relays monitor AC single phase currents for over or under current conditions. A separate 24 or
120VAC input (supply) voltage is required to power these units. Three current ranges are available: 0.1 – 1A;
0.5 – 5A; and 1 – 10A. An external current transformer may be used to extend the range of these products (see
Typical Installations below). All versions are available in a compact plug-in case utilizing industry-standard 8 or 11 pin
octal sockets.
The Reference Guide below provides general information on the different versions of Current Monitor Relays offered
by Macromatic (see Product Selection on the following pages for further details):
Pick-up
Type
Series
Standard
CMP
(Fixed time delay on
both pick-up and dropout current settings)
CMKP
Overcurrent
COP
(Adjustable time delay
on pick-up and fixed
time delay on drop-out
current settings)
COKP
Drop-out
Setting
Time Delay
Adjustable
(Across Monitored Range)
Fixed 100ms *
Adjustable
(Across Monitored Range)
0.1-10 sec
Adjustable
Fixed (+5% Drop-out)
Fixed 100ms *
Setting
Time Delay
Fixed (-5% Pick-up)
Fixed 100ms *
Adjustable (50-95% Pick-up)
Fixed 100ms *
Fixed (-5% Pick-up)
Fixed 100ms *
Adjustable (50-95% Pick-up)
Fixed 100ms *
Adjustable
(Across Monitored Range)
0.1-10 sec
Adjustable
See
Page
18
20
Undercurrent
(Fixed time delay on
pick-up and adjustable
time delay on drop-out
current settings)
CUP
22
*Fixed time delay eliminates nuisance tripping due to short current surges or drops.
Approvals
All Macromatic plug-in Current Monitor Relays are UL Component Recognized. We are also in the process of obtaining
UL Listing when used with the appropriate Macromatic socket--check with Macromatic for updated information.
Typical Installations
Without External CT
With External CT
17
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CM Series Standard
!
Monitors AC single phase
currents
!
Three separate current
monitoring ranges covering
0.1 - 10 amperes
!
External CT can be used to
extend ranges
!
Adjustable Pick-up Setting
with either Fixed or Adjustable Drop-out Setting
!
LED indicates output relay
status
!
Choice of compact 8 Pin
SPDT or 11 Pin DPDT plugin case
!
10A output contacts
NEW
PRODUCT
The CM Series is used to detect either an overcurrent or undercurrent condition. The pickup current setting is user-adjustable within one of three ranges as shown in the Product
Selection Table below. An
external current transformer can
be used to extend the range
beyond 10 amperes.
Choose between a fixed drop-out
current setting at 95% of the
selected pick-up setting or an
adjustable drop-out setting of 5095% of the selected pick-up
setting. The relay will energize
when the monitored AC current is
above the pick-up setting, and will
de-energize when the monitored AC current is below the drop-out setting. The time delay
on both pick-up and drop-out is fixed at 100ms (for products with adjustable time delay on
pick-up, see page 20; for adjustable time delay on drop-out, see page 22).
SPDT 8 Pin Plug-in
!
(with appropriate socketListing Pending)
Pick-up
Setting
Adjustable
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
CMP01A68
CMP05A68
CMP10A68
CMP01A62
CMP05A62
CMP10A62
8 Pin
70169-D
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
CMKP01A68
CMKP05A68
CMKP10A68
CMKP01A62
CMKP05A62
CMKP10A62
Diagram 21
(At 95% of
Pick-Up)
120V AC
Adjustable
Adjustable
24V AC
(From 50-95%
of Pick-Up)
120V AC
DPDT 11 Pin Plug-in
Pick-up
Setting
Adjustable
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
CMP01A28
CMP05A28
CMP10A28
CMP01A22
CMP05A22
CMP10A22
11 Pin
70170-D
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
CMKP01A28
CMKP05A28
CMKP10A28
CMKP01A22
CMKP05A22
CMKP10A22
(At 95% of
Pick-Up)
120V AC
Adjustable
Adjustable
24V AC
(From 50-95%
of Pick-Up)
800-238-7474
120V AC
www.macromatic.com
whats-up@macromatic.com
18
Sockets & Accessories−Page 16
Dimensions−Page 19
Application Data−Page 19
Diagram 22
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CM Series Standard
Application Data & Dimensions
Application Data
Input Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
Load (Burden):
Less than 5VA
Current Settings:
Pick-up: Adjustable throughout current range monitored
Drop-out: Fixed at 95% of pick-up setting (CMP Series); or
Adjustable from 50-95% of pick-up setting (CMKP
Series)
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Indicator LED: Green when Input Voltage is applied;
Red when Relay is energized
Reset: Automatic. Contact Macromatic for information
on a product with a latching function--the relay remains
energized even after the current drops below the dropout setting until a remote N.C. button is opened.
Temperature:
-28o to 55o C (-20o to 131o F)
Mounting:
Requires an 8 or 11 pin octal socket--see page 16.
Response Times:
Pick-up:
100ms
Drop-out: 100ms
Approvals:
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.),
1/3HP @ 240V AC (N.C.)
File #E109466
with appropriate
Macromatic socket-Listing Pending
File #E109466
Dimensions
2.4 (60)
CMKP
Only
2.9
(74)
1.7
(43)
3.5
(89)
All dimensions are inches
(millimeters)
19
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CO Series Overcurrent
!
Monitors AC single phase
currents for overcurrent
conditions
!
Three separate current
monitoring ranges covering
0.1 - 10 amperes
!
External CT can be used to
extend ranges
!
Adjustable Pick-up Setting
with either Fixed or Adjustable Drop-out Setting
!
Adjustable time delay of 0.110 seconds on pick-up
!
LED indicates output relay
status
!
Choice of compact 8 Pin
SPDT or 11 Pin DPDT plugin case
!
10A output contacts
NEW
PRODUCT
The CO Series is used to detect an overcurrent condition. The pick-up current setting is
user-adjustable within one of three ranges as shown in the Product Selection Table below.
An external current transformer can
be used to extend the range beyond
10 amperes.
Choose between a fixed drop-out
current setting at 95% of the
selected pick-up setting or an
adjustable drop-out setting of 5095% of the selected pick-up setting.
The relay will energize when the
monitored AC current is above the
pick-up setting for a period longer
than the adjustable time delay of 0.1-10 seconds. This delay prevents nuisance tripping
caused by inrush currents. It will de-energize when the monitored AC current is below the
drop-out setting.
8 Pin SPDT Plug-in
Pick-up
Setting
Adjustable
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
COP01A68
COP05A68
COP10A68
COP01A62
COP05A62
COP10A62
8 Pin
70169-D
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
COKP01A68
COKP05A68
COKP10A68
COKP01A62
COKP05A62
COKP10A62
Diagram 21
(At 95% of
!
Pick-Up)
120V AC
(with appropriate socketListing Pending)
Adjustable
Adjustable
24V AC
(From 50-95%
of Pick-Up)
120V AC
11 Pin DPDT Plug-in
Pick-up
Setting
Adjustable
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
COP01A28
COP05A28
COP10A28
COP01A22
COP05A22
COP10A22
11 Pin
70170-D
0.1 - 1A
0.5 - 5A
1 - 10A
0.1 - 1A
0.5 - 5A
1 - 10A
COKP01A28
COKP05A28
COKP10A28
COKP01A22
COKP05A22
COKP10A22
(At 95% of
Pick-Up)
120VAC
Adjustable
Adjustable
24V AC
(From 50-95%
of Pick-Up)
800-238-7474
www.macromatic.com
whats-up@macromatic.com
20
120V AC
Sockets & Accessories−Page 16
Dimensions−Page 21
Application Data−Page 21
Diagram 22
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CO Series Overcurrent
Application Data & Dimensions
Application Data
Input Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
Load (Burden):
Less than 5VA
Current Settings:
Pick-up: Adjustable throughout current range monitored
Drop-out: Fixed at 95% of pick-up setting (COP Series); or
Adjustable from 50-95% of pick-up setting (COKP
Series)
Temperature:
-28o to 55o C (-20o to 131o F)
Response Times:
Pick-up:
Adjustable 0.1-10 seconds
Drop-out: Fixed 100ms
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.),
1/3HP @ 240V AC (N.C.)
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Indicator LED: Green when Input Voltage is applied;
Red Flashing when in time delay; and Red Steady when
Relay is energized.
Reset: Automatic. Contact Macromatic for information
on a product with a latching function--the relay remains
energized even after the current drops below the dropout setting until a remote N.C. button is opened.
Mounting:
Requires an 8 or 11 pin octal socket--see page 16.
Approvals:
File #E109466
with appropriate
Macromatic socket-Listing Pending
File #E109466
Dimensions
2.4 (60)
COKP
Only
2.9
(74)
1.7
(43)
3.5
(89)
All dimensions are inches
(millimeters)
21
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CU Series Undercurrent
!
Monitors AC single phase
currents for undercurrent
conditions
!
Three separate current
monitoring ranges covering
0.1 - 10 amperes
!
External CT can be used to
extend ranges
!
Adjustable Drop-out Setting
with Fixed Pick-up Setting
!
Adjustable time delay of 0.110 seconds on drop-out
!
LED indicates output relay
status
!
Choice of compact 8 Pin
SPDT or 11 Pin DPDT plugin case
!
10A output contacts
!
NEW
PRODUCT
The CU Series is used to detect an undercurrent condition. The drop-out current setting is
user-adjustable within one of three ranges as shown in the Product Selection Table below.
An external current transformer can
be used to extend the range
beyond 10 amperes.
The pick-up current setting is fixed
at +5% of the selected drop-out
setting. The relay will energize
when the monitored AC current is
above the pick-up setting. It will
de-energize when the monitored
AC current is below the drop-out
setting for a period longer than the
adjustable time delay of 0.1-10
seconds. This delay prevents nuisance tripping caused by momentary line dips. The relay
will energize when the current rises 5% above the drop-out setting.
8 Pin SPDT Plug-in
Pick-up
Setting
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
Adjustable
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
CUP01A68
CUP05A68
CUP10A68
8 Pin
70169-D
120V AC
0.1 - 1A
0.5 - 5A
1 - 10A
CUP01A62
CUP05A62
CUP10A62
(At +5% of
(with appropriate socketListing Pending)
Drop-Out)
Diagram 21
11 Pin DPDT Plug-in
Pick-up
Setting
Drop-Out
Setting
Input
Voltage
Current Range
Monitored
Product
Number
Wiring/
Socket
Fixed
Adjustable
24V AC
0.1 - 1A
0.5 - 5A
1 - 10A
CUP01A28
CUP05A28
CUP10A28
11 Pin
70170-D
120V AC
0.1 - 1A
0.5 - 5A
1 - 10A
CUP01A22
CUP05A22
CUP10A22
(At +5% of
Drop-Out)
800-238-7474
Diagram 22
www.macromatic.com
whats-up@macromatic.com
22
Sockets & Accessories−Page 16
Dimensions−Page 23
Application Data−Page 23
CURRENT MONITOR RELA
YS
RELAYS
AC Plug-in
CU Series Undercurrent
Application Data & Dimensions
Application Data
Input Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
Load (Burden):
Less than 5VA
Current Settings:
Pick-up: Fixed at 5% above adjustable drop-out setting
Drop-out: Adjustable throughout current range monitored
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Indicator LED: Green when Input Voltage is applied;
Red Flashing when in time delay; and Red Steady when
Relay is energized.
Reset: Automatic
Temperature:
-28o to 55o C (-20o to 131o F)
Mounting:
Requires an 8 or 11 pin octal socket--see page 16.
Response Times:
Pick-up:
Fixed 100ms
Drop-out: Adjustable 0.1-10 seconds
Approvals:
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.),
1/3HP @ 240V AC (N.C.)
File #E109466
with appropriate
Macromatic socket-Listing Pending
File #E109466
Dimensions
2.4 (60)
2.9
(74)
1.7
(43)
3.5
(89)
All dimensions are inches
(millimeters)
23
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
Product Summar
y
Summary
Voltage Monitor Relays monitor either AC single phase (50-60Hz) or DC voltages to protect equipment against voltage fault
conditions. No separate supply (input) voltage is required on any Macromatic Voltage Monitor Relays. All versions are available
in a compact plug-in case utilizing an 8 pin octal socket.
Macromatic offers two styles of Voltage Monitor Relays:
!
Over/Under Voltage Relays--provides protection to equipment where either an over or under voltage condition is
potentially damaging. When used as an under voltage relay, they provide protection to equipment that is required to
operate above a minimum voltage. When used as over voltage relays, they protection equipment against excessive
voltage conditions. Over/Under Voltage Relays are designed to operate when the operating voltage reaches a preset
value and drop-out when the operating voltage drops to a level below the preset value.
!
Voltage Band Relays--provides protection to equipment that is required to operate within an upper & lower voltage limit.
As long as the operating voltage remains within an OVER & UNDER voltage range, the internal relay stays energized. If
the operating voltage falls outside this range, the relay will drop-out.
These products are summarized below:
Over/Undervoltage Relays
Pick-up
Voltage
Drop-out
Voltage
Time Delay
Drop-Out
VMP
Adjustable 85115% Nominal
Fixed at 95% of
Pick-Up
Fixed 500ms *
25
VMKP
Adjustable 85115% Nominal
Adjustable 7595% of Pick-up
Fixed 500ms *
25
VAP
Adjustable 85115% Nominal
Fixed at 95% of
Pick-Up
Adjustable
0.5-10 seconds
26
VAKP
Adjustable 85115% Nominal
Adjustable 7595% of Pick-up
Adjustable
0.5-10 seconds
26
Series
Function
Chart
Page
Voltage Band Relays
Over Voltage
Voltage
Under Voltage
Voltage
Time Delay
Drop-Out
VWP
Adjustable
100-125%
of Nominal
Adjustable
75-100%
of Nominal
Fixed 500ms *
28
VWKP
Adjustable
100-125%
of Nominal
Adjustable
75-100%
of Nominal
Adjustable
0.5-10 seconds
28
Series
Function
Chart
Page
*Fixed time delay eliminates nuisance tripping due to short voltage surges or drops.
Approvals
All Macromatic plug-in Voltage Monitor Relays are UL Component Recognized. We are also in the process of obtaining
UL Listing when used with the appropriate Macromatic socket--check with Macromatic for updated information.
24
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
VM Series Over/Under
voltage
Over/Undervoltage
Fixed Time Delay on Drop-Out
NEW
PRODUCT
Over/Under Voltage Relays provide protection to equipment where either an over or
under voltage condition is potentially damaging. They are designed to operate when the
operating voltage reaches a preset value and drop-out when the operating voltage drops
to a level below the preset value.
The pick-up voltage setting is useradjustable from 85-115% of the
nominal voltage rating. As
standard, the VMP Series has a
drop-out voltage setting fixed at
95% of the pick-up voltage setting.
An adjustable drop-out setting of
75-95% of the pick-up setting is
available on the VMKP Series.
The relay energizes when the
monitored voltage is above the pick-up setting. The relay de-energizes when the
monitored voltage is below the drop-out setting for a period longer than the drop-out time
delay (T), which is a fixed 500ms for VM Series products. An adjustable time delay on
drop-out of 0.5-10 seconds is available (see Page 26).
!
Monitors AC single phase
and DC voltages
!
Wide range of user-adjustable pick-up and drop-out
settings
!
Fixed time delay on drop-out
of 500ms
!
LED indicates output relay
status
!
Compact plug-in case
utilizing industry standard 8
pin octal socket
!
10A DPDT output contacts
!
(with appropriate socketListing Pending)
Adjustable Pick-Up, Fixed Drop-Out Settings *
Time Delay on Drop-out Fixed at 500ms
NOMINAL
VOLTAGE#
#
*
PICK-UP
DROP-OUT
VOLTAGE RANGE VOLTAGE RANGE*
PRODUCT
NUMBER
WIRING/
SOCKET
24V AC
120V AC
21-27V AC
102-138V AC
20-26V AC
99-134V AC
VMP024A
VMP120A
8 Pin Octal
70169-D
12V DC
24V DC
48V DC
110V DC
10-14V DC
21-27V DC
41-55V DC
94-126V DC
9-13V DC
20-26V DC
39-53V DC
91-122V DC
VMP012D
VMP024D
VMP048D
VMP110D
DIAGRAM 20
Drop-out Voltage is fixed at 95% of the adjusted Pick-up Setting.
Adjustable Pick-Up & Drop-Out Settings **
Time Delay on Drop-out Fixed at 500ms
NOMINAL
PICK-UP
DROP-OUT
VOLTAGE#
# VOLTAGE RANGE VOLTAGE RANGE
24V AC
120V AC
21-27V AC
102-138V AC
16-26V AC
77-131V AC
PRODUCT
NUMBER"
"
WIRING/
SOCKET
VMKP024A
VMKP120A
8 Pin Octal
70169-D
12V DC
10-14V DC
8-13V DC
VMKP012D
24V DC
21-27V DC
16-26V DC
VMKP024D
48V DC
41-55V DC
32-52V DC
VMKP048D
110V DC
94-126V DC
71-119V DC
VMKP110D
DIAGRAM 20
** Drop-out Voltage is adjustable from 75-95% of the adjusted Pick-up Setting.
# Contact Macromatic for information on units above 120V.
" These products replace those products previously sold with a suffix “-G”--contact
Macromatic for more information.
Sockets & Accessories−Page 16
800-238-7474
www.macromatic.com
whats-up@macromatic.com
Application Data/Dimensions−Page 27
25
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
VA Series Over/Under
voltage
Over/Undervoltage
NEW
PRODUCT
Adjustable Time Delay on Drop-Out
!
Monitors AC single phase
and DC voltages
!
Wide range of user-adjustable pick-up and drop-out
settings
!
Adjustable time delay on
drop-out of 0.1 - 10 seconds
!
LED indicates output relay
status
!
Compact plug-in case
utilizing industry standard 8
pin octal socket
!
10A DPDT output contacts
!
(with appropriate socketListing Pending)
Over/Under Voltage Relays provide protection to equipment where an over or under
voltage condition is potentially damaging. They are designed to operate when the
operating voltage reaches a preset value and drop-out when the operating voltage drops
to a level below the preset value.
The pick-up voltage setting is useradjustable from 85-115% of the
nominal voltage rating. As standard, the VAP Series has a dropout voltage setting fixed at 95% of
the pick-up voltage setting. An
adjustable drop-out setting of 7595% of the pick-up setting is
available on the VAKP Series. The
relay energizes when the monitored voltage is above the pick-up
setting. The relay de-energizes when the monitored voltage is below the drop-out setting
for a period longer than the drop-out time delay (T), which is adjustable from 0.5-10
seconds for VA Series products. A time delay on drop-out fixed at 500ms is available
(see Page 25).
Adjustable Pick-Up, Fixed Drop-Out Settings *
Adjustable Time Delay on Drop-out from 0.5 - 10 Seconds
NOMINAL
VOLTAGE#
#
24V AC
120V AC
PICK-UP
DROP-OUT
VOLTAGE RANGE VOLTAGE RANGE*
21-27V AC
102-138V AC
20-26V AC
99-134V AC
PRODUCT
NUMBER
WIRING/
SOCKET
VAP024A
VAP120A
8 Pin Octal
70169-D
12V DC
10-14V DC
9-13V DC
VAP012D
24V DC
21-27V DC
20-26V DC
VAP024D
48V DC
41-55V DC
39-53V DC
VAP048D
110V DC
94-126V DC
91-122V DC
VAP110D
* Drop-out Voltage is fixed at 95% of the adjusted Pick-up Setting.
DIAGRAM 20
Adjustable Pick-Up & Drop-Out Settings **
Adjustable Time Delay on Drop-out from 0.5 - 10 Seconds
NOMINAL
PICK-UP
DROP-OUT
VOLTAGE#
# VOLTAGE RANGE VOLTAGE RANGE
24V AC
120V AC
800-238-7474
www.macromatic.com
whats-up@macromatic.com
26
21-27V AC
102-138V AC
16-26V AC
77-131V AC
PRODUCT
NUMBER
WIRING/
SOCKET
VAKP024A
VAKP120A
8 Pin Octal
70169-D
12V DC
10-14V DC
8-13V DC
VAKP012D
24V DC
21-27V DC
16-26V DC
VAKP024D
48V DC
41-55V DC
32-52V DC
VAKP048D
110V DC
94-126V DC
71-119V DC
VAKP110D
DIAGRAM 20
** Drop-out Voltage is adjustable from 75-95% of the adjusted Pick-up Setting.
# Contact Macromatic for information on units above 120V.
Sockets & Accessories−Page 16
Application Data/Dimensions−Page 27
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
VM & V
A Series Over/Under
voltage
VA
Over/Undervoltage
Application Data & Dimensions
Operating Modes
These relays can be used as either overvoltage or undervoltage relays, depending on the output contact used:
Undervoltage Relay
Provides protection to equipment that is required to
operate above a certain minimum voltage. Uses a
normally open contact (N.O.). As long as the monitored
voltage is above the minimum value required (Pick-Up
Setting), the relay will energize and the N.O. contact
closes, turning on the load. If the voltage drops below the
Drop-out Setting (the minimum voltage required minus
the hysteresis), the relay will de-energize and the N.O.
contact will re-open, turning off the load.
Overvoltage Relay
Provides protection to equipment that cannot handle excess
voltages. Uses a normally closed contact (N.C.). As long as the
monitored voltage remains below the maximum voltage the
equipment can withstand (Pick-Up Setting), the relay remains deenergized and the N.C. contact remains closed, keeping the load
energized. If the operating voltage increases beyond the maximum rating of the equipment, the relay energizes and the N.C.
contact opens, turning off the load. When the voltage falls below
the Drop-Out Setting (hysteresis), the relay de-energizes and the
N.C. contact re-closes, turning on the load.
Application Data
Voltage Tolerance:
+25%/-50% of nominal voltage; AC voltages are 50-60Hz;
No supply (input) voltage is required.
Load (Burden): Less than 3VA
Voltage Settings:
Pick-up: Adjustable from 85-115% of nominal voltage
Drop-out: Fixed at 95% of the pick-up setting (VMP & VAP Series)
Adjustable from 75-95% of pick-up setting (VMKP &
VAKP Series)
Temperature:
-28o to 55o C (-20o to 131o F)
Response Times:
Operate: 500ms
Release: Fixed 500 ms (VMP & VMKP Series)
Adjustable 0.5 - 10 Seconds (VAP & VAKP Series)
Indicator LED: Red Steady when Relay is energized; Green
when Relay is Off; and Red Flashing when in time delay.
Transient Protection:
10,000 volts for 20 microseconds
Reset: Automatic. Contact Macromatic for information on
how to order a unit with Manual Reset.
Approvals:
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.),
1/3HP @ 240V AC (N.C.)
File #E109466
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
with appropriate
Macromatic socket-Listing Pending
File #E109466
Dimensions
2.4 (60)
VMKP & VAKP
Only
2.9 (74)
3.5 (89)
1.7 (43)
All Dimensions in
Inches (Millimeters)
27
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
VW Series V
oltage Band
Voltage
NEW
PRODUCT
!
Monitors AC single phase
and DC voltages
!
Provides voltage band
(window) protection
!
Wide range of user-adjustable Over Voltage and
Under Voltage settings
!
Fixed or adjustable time
delay on drop-out
!
LED indicates output relay
status
!
Compact plug-in case
utilizing industry standard 8
pin octal socket
!
10A DPDT output contacts
!
Voltage Band Relays provide protection to equipment that is required to operate
within an upper & lower voltage limit. As long as the operating voltage remains
within an OVER & UNDER voltage range, the internal relay stays energized. If
the operating voltage falls outside this range, the relay will drop-out.
When nominal operating
voltage is applied, the internal
relay will energize (Pick-up).
If the operating voltage falls
outside the preset OVER trip
point (adjustable 100-125% of
nominal) or UNDER trip point
(adjustable 75-100% of
nominal) for a period longer
than the drop-out time delay (T), the relay will de-energize (Drop-out). When the
voltage returns to normal (within the preset OVER & UNDER trip points), the unit
automatically resets and the relay energizes. Choose between a unit with fixed
drop-out time of 500ms or one with an adjustable 0.5-10 second drop-out time.
(with appropriate socketListing Pending)
Fixed Drop-Out Time Delay (500ms)
NOMINAL
VOLTAGE#
#
OVER VOLTAGE
RANGE
UNDER VOLTAGE
RANGE
PRODUCT
NUMBER
WIRING/
SOCKET
24V AC
120V AC
24-30V AC
120-150V AC
18-24V AC
90-120V AC
VWP024A
VWP120A
8 Pin Octal
70169-D
12V DC
24V DC
48V DC
110V DC
12-15V DC
24-30V DC
48-60V DC
110-137V DC
9-12V DC
18-24V DC
36-48V DC
83-110V DC
VWP012D
VWP024D
VWP048D
VWP110D
DIAGRAM 20
Adjustable Drop-Out Time Delay 0.5 - 10 Seconds
800-238-7474
www.macromatic.com
whats-up@macromatic.com
NOMINAL
VOLTAGE#
#
OVER VOLTAGE
RANGE
UNDER VOLTAGE
RANGE
PRODUCT
NUMBER
WIRING/
SOCKET
24V AC
120V AC
24-30V AC
120-150V AC
18-24V AC
90-120V AC
VWKP024A
VWKP120A
8 Pin Octal
70169-D
12V DC
12-15V DC
24V DC
24-30V DC
48V DC
48-60V DC
110V DC
110-137V DC
# Contact Macromatic for information
Sockets & Accessories-Page 16
28
9-12V DC
VWKP012D
18-24V DC
VWKP024D
36-48V DC
VWKP048D
83-110V DC
VWKP110D
on units above 120V.
DIAGRAM 20
Application Data/Dimensions-Page 29
VOL
TAGE MONITOR RELA
YS
VOLT
RELAYS
VW Series V
oltage Band
Voltage
Application Data & Dimensions
Application Data
Voltage Tolerance:
+25%/-50% of nominal voltage; AC voltages are 50-60Hz;
No supply (input) voltage is required.
Load (Burden): Less than 3VA
Response Times:
Operate: 500ms
Release: Fixed 500 ms (VWP Series)
Adjustable 0.5 -10 Seconds (VWKP Series)
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC (N.O.),
1/3HP @ 240V AC (N.C.)
Voltage Settings:
Over Voltage:
100-125% of Nominal Voltage
Under Voltage: 75-100% of Nominal Voltage
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Temperature:
-28o to 55o C (-20o to 131o F)
Indicator LED: Red Steady when Relay is energized; Green
when Relay is Off; and Red Flashing when in time delay.
Reset: Automatic. Contact Macromatic for information on how
to order a unit with Manual Reset.
Transient Protection:
10,000 volts for 20 microseconds
Approvals:
File #E109466
with appropriate
Macromatic socket-Listing Pending
File #E109466
Dimensions
2.4 (60)
VWKP Only
2.9 (74)
1.7 (43)
3.5 (89)
All Dimensions in
Inches (Millimeters)
29
TIME DELA
Y RELA
YS
DELAY
RELAYS
Product Summar
y
Summary
Macromatic offers a wide variety of time delay relays and accessories. Each one has different features and operating
characteristics, allowing you to choose the exact product to meet your needs. Our time delay relays are available in
either programmable or non-programmable versions. We offer both single or multiple function time delay relays.
Choose between SPDT or DPDT relay outputs. Time delay relays are available as plug-in units for use with industry
standard 8 & 11 pin octal or 11 pin blade sockets, or as an open board version for OEM applications. Choose between
analog or digital-set time delay relays. Refer to the Selection Table on these two pages for more information.
Series
Standard
Non-Programmable
Single-Range
Plug-in
Time Ranger
Multi-Range
Programmable
Plug-in
Compact
Non-Programmable
Single-Range
Plug-in
TR-5
TR-6
SS-6 & SS-8
On Delay
Interval On
Off Delay
Single Shot
*
*
*
*
*
*
*
*
Timing Ranges
Available
20 separate timing ranges
from 0.02 Seconds to 24
Hours
16 field-programmable timing
ranges covering up to 2
Hours (24 Hours on Dual
Knob units) in one unit
6 separate timing ranges
from 0.02 to 300 Seconds
Output Contacts
DPDT or SPDT
10A @ 240V AC
10A @ 28V DC
1/2HP @ 240V AC
1/3HP @ 120V AC
B300/R300
DPDT
10A @ 240V AC
10A @ 28V DC
1/2HP @ 240V AC
1/3HP @ 120V AC
B300/R300
SPDT
5A @ 120V AC
5A @ 28V DC
1/6HP @ 120V AC
12V AC/DC,
24V AC/DC,
120V AC/DC &
240V AC
12V AC/DC,
24V AC/DC,
120V AC/DC &
240V AC
12V AC/DC,
24V AC/DC &
120V AC
Input Voltages
*
*
*
*
*
*
*
*
On Delay
Interval On
Flasher
Off Delay
Single Shot
Watchdog
Repeat Cycle
Delayed Interval
*
*
*
*
On Delay
Interval On
Flasher
Off Delay
Single Shot
Watchdog
Repeat Cycle
Delayed Interval
Timing Functions
Available
Approvals
with appropriate socket
See Page
30
34-39
with appropriate socket
40-43
with appropriate socket
44
TIME DELA
Y RELA
YS
DELAY
RELAYS
Product Summar
y
Summary
See pages 32 & 33 for a detailed description of all timing functions available. If you have any questions regarding the
selection or application of time delay relays, either visit our on-line Technical Resource Center (www.macromatic.com)
or call us at 800-238-7474.
Need modifications such as fixed time delays, remote adjustments or special pin configurations? We can do most of
these modifications within our normal lead-times. See pages 50 & 51 for more information.
Spade Base
Non-Programmable
Single Range
Plug-in
Time Ranger
Digital-Set
Multi-Range
Programmable
Plug-in
Time Ranger III
Digital-Set
Multi-Function
Multi-Range
Programmable
SS-4
TD-7
981
Series
Timing Functions
Available
* On Delay
* Off Delay
*
*
*
*
*
On Delay
Interval On
Flasher
Off Delay
Single Shot
Available in both single
function & multifunction
All in One Unit:
* On Delay
* Interval On
* Flasher
* Off Delay (2 versions)
* Interval On/Off Delay
* On Delay/Off Delay
* Delayed Interval
Timing Ranges
Available
3 separate timing ranges
from 0.1 to
300 Seconds
0.05 Seconds to
999 Hours
programmable timing range
0.1 Seconds to
9,999 Hours
programmable timing range
Output Contacts
DPDT
12A @ 240V AC
12A @ 30V DC
1/2HP @ 240V AC
B300/R300
DPDT
10A @ 240V AC
10A @ 28V DC
1/2HP @ 240V AC
1/3HP @ 120V AC
B300/R300
SPDT
3A @ 240V AC
5A @ 30V DC
1/2HP @ 240V AC
12V AC/DC,
24V AC/DC &
120V AC
12V AC/DC,
24V AC/DC,
120V AC/DC &
240V AC
24-240V AC &
12-240V DC in one unit
Input Voltages
Approvals
with appropriate socket
See Page
45
with appropriate socket
46-47
48-49
31
TIME DELA
Y RELA
YS
DELAY
RELAYS
Definition of Timing Functions
Understanding the differences between all the functions available in time delay relays can sometimes be a daunting task. To
begin with, time delay relays are simply control relays with a time delay built in. Their purpose is to control an event based on
time.
Typically, time delay relays are initiated or triggered by one of two methods:
! application of input voltage (On Delay, Interval On, Flasher, Repeat Cycle & Delayed Interval)
! opening or closing of a trigger signal (Off Delay, Single Shot, Watchdog & Triggered Delayed Interval)
These trigger signals can be one of two designs: a control switch (dry contact), i.e., limit switch, push button, float switch, etc., or
by voltage (commonly known as a power trigger).
To help understand, some definitions are important:
! Input Voltage-control voltage applied to the input terminals. Depending on the function, input voltage will either initiate
the unit or make it ready to initiate when a trigger signal is applied.
! Trigger Signal-on certain timing functions, a trigger signal is used to initiate the unit after input voltage has been applied.
As noted above, this trigger signal can either be a control switch (dry contact switch) or a power trigger (voltage).
! Output (Load)-every time delay relay has an internal relay (usually mechanical) with contacts that open & close to control
the load. They are represented by the dotted lines in the wiring diagrams. Note that the user must provide the voltage to
power the load being switched by the output contacts of the time delay relay.
Below and on the following page are both written and visual descriptions on how the common timing functions operate. A Timing
Chart shows the relationship between Input Voltage, Trigger Signal (if present) and Output Contacts. If you cannot find a product
to fit your requirements or have any questions, Macromatic’s Application Engineers offer technical information along with product
selection and application assistance. Just call us at 800-238-7474 or e-mail us at tech-help@macromatic.com.
○
○
Function
Operation
ON DELAY
Delay on Operate
Delay on Make
Upon application of input voltage, the preset time
begins. At the end of the preset time, the relay
contacts transfer. Input voltage must be removed
and reapplied to reset the time delay relay.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
SINGLE SHOT
One Shot
Momentary
Interval
32
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Upon application of input voltage, the time delay
relay is ready to accept trigger signals. Upon
application of the trigger signal, the relay contacts
transfer and hold. Upon release of the trigger
signal, the preset time begins and the relay
contacts stay held. At the end of the preset time,
the relay contacts return to their normal condition.
Any application of the trigger signal will reset the
time.
OFF DELAY
Delay on Release
Delay on
De-Energization
Delay on Drop-Out
○
○
Upon application of input voltage, the relay
contacts transfer and the preset time begins. At
the end of the preset time, the contacts return to
their normal condition. Input voltage must be
removed and reapplied to reset the time delay
relay.
INTERVAL ON
Interval
○
○
Timing Chart
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Upon application of input voltage, the time delay
relay is ready to accept trigger signals. Upon
application of the trigger signal, the relay contacts
transfer and the preset time begins. During timeout, the trigger signal is ignored. The time delay
relay is reset by applying the trigger signal when
the relay is not energized.
TIME DELA
Y RELA
YS
DELAY
RELAYS
Definition of Timing Functions
○
○
Function
Operation
WATCHDOG
Retriggerable
Single Shot
Upon application of input voltage, the time delay
relay is ready to accept trigger signals. Upon
application of the trigger signal, the relay contacts
transfer and the preset time begins. At the end of
the preset time, the relay contacts return to their
normal condition unless the trigger signal is opened
and closed prior to time out (before preset time
elapses). Continuous cycling of the trigger signal at
a rate faster than the preset time will cause the
relay contacts to remain closed.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Upon application of input voltage, a preset delay
begins (OFF). At the end of the preset delay, the
relay contacts transfer and remain in that condition
for a second, independently adjustable preset time
(ON). At the end of this time, the contacts drop out
and the sequence stops. Input voltage must be
removed and reapplied to reset the time delay
relay.
DELAYED
INTERVAL
Single Cycle
○
○
Upon application of input voltage, the relay contacts
transfer and a preset delay begins. At the end of
the preset delay, the relay contacts drop out and
remain in that condition for a second, independently
adjustable preset time. At the end of this time, the
relay contacts pull in and the sequence repeats
until input voltage is removed.
REPEAT CYCLE
On/Off Delay
○
○
Upon application of input voltage, a preset delay
begins. At the end of the preset delay, the relay
contacts transfer and remain in that condition for a
second, independently adjustable preset time. At
the end of this time, the relay contacts drop out and
the sequence repeats until input voltage is removed.
REPEAT CYCLE
Off/On Delay
○
○
Upon application of the input voltage, the preset
time (T1) begins. At the end of the preset time, the
relay contacts transfer and remain in that condition
for the preset time (T1). At the end of this time, the
relay contacts drop out and the sequence repeats
until input voltage is removed.
FLASHER
○
○
Timing Chart
○
DELAYED
INTERVAL
(TRIGGERED)
Single Cycle
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Upon application of input voltage, the time delay
relay is ready to accept trigger signals. Upon
application of the trigger signal, a preset delay
begins (OFF). At the end of the preset delay, the
relay contacts transfer and remain in that condition
for a second, independently adjustable preset time
(ON). At the end of the second preset time, the
relay contacts return to their normal condition.
During timing, the trigger signal is ignored.
33
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
On Delay
val & Flasher
Delay,, Inter
Interval
!
Each unit has a single timing
range
!
Choose from 20 separate
timing ranges from
0.02 Seconds to 24 Hours
!
Uses industry-standard 8 pin
octal sockets
!
10A DPDT output contacts
FUNCTION "
WIRING/
SOCKETS !
FROM TABLE BELOW
ON DELAY
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-50222-**
TR-50226-**
TR-50228-**
TR-50221-**
INTERVAL ON
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-50522-**
TR-50526-**
TR-50528-**
TR-50521-**
FLASHER
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-50822-**
TR-50826-**
TR-50828-**
TR-50821-**
!
with
appropriate
socket
SINGLE KNOB UNITS
PRODUCT
INPUT
NUMBER **
COMPLETE PRODUCT
VOLTAGE
NUMBER USING 2 DIGIT CODE
8 PIN OCTAL !
70169-D
DIAGRAM 1
" See Pages 32-33 for definitions & explanations of Timing Functions.
! Note: if these products are ordered with the Remote Adjust Potentiometer modification
(suffix -Rx), they will require an 11 pin octal socket−see Page 50 for more information.
Sockets & Accessories−Page 58
Dimensions−Page 37
Application Data−Page 37
Standard Modifications−Pages 50-51
Timing Ranges
** TIMING RANGE TABLE
COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE
FROM TABLE BELOW
i.e., TR-50222-04
Time Delay Range
0.02 - 2 Sec.
0.05 - 5 Sec.
0.1 - 10 Sec.
0.15 - 15 Sec.
0.3 - 30 Sec.
0.6 - 60 Sec.
1.2 - 120 Sec.
1.8 - 180 Sec.
3 - 300 Sec.
4.5 - 450 Sec.
Code
03
04
05
06
07
08
09
10
12
13
Time Delay Range Code
6 Sec. - 10 Min.
22
9 Sec. - 15 Min.
14
0.3 - 30 Min.
15
0.6 - 60 Min.
16
1.2 - 120 Min. 17
1.8 - 180 Min. 18
2.4 Min. - 4 Hr.
19
4.8 Min. - 8 Hr.
20
7.2 Min. - 12 Hr.
21
14.4 Min. - 24 Hr.
23
For Fixed Time Delay (at no additional charge), add suffix “F”
and time delay desired to basic Product Number, i.e., TR-50222F5S is an On Delay with a time delay fixed at 5 seconds.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
34
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
Off Delay
atchdog
Delay,, Single Shot & W
Watchdog
FUNCTION " !
SINGLE KNOB UNITS
PRODUCT
INPUT
NUMBER **
COMPLETE PRODUCT
VOLTAGE
NUMBER USING 2 DIGIT CODE
WIRING/
SOCKETS
FROM TABLE BELOW
OFF DELAY
Control Switch Trigger
SINGLE SHOT
Control Switch Trigger
WATCHDOG
Control Switch Trigger
(Retriggerable
Single Shot)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-51622-**
TR-51626-**
TR-51628-**
TR-51621-**
TR-51522-**
TR-51526-**
TR-51528-**
TR-51521-**
TR-51322-**
TR-51326-**
TR-51328-**
TR-51321-**
!
Each unit has a single timing
range
!
Choose from 20 separate
timing ranges from
0.02 Seconds to 24 Hours
!
Uses industry-standard
11 pin octal sockets
!
10A DPDT output contacts
11 PIN OCTAL
70170-D
!
DIAGRAM 2
with
appropriate
socket
OFF DELAY
Power Trigger
120V AC/DC
TR-51922-**
11 PIN OCTAL
12V AC/DC
TR-51926-**
70170-D
24V AC/DC
TR-51928-**
240V AC
TR-51921-**
SINGLE SHOT
120V AC/DC
TR-51722-**
Power Trigger
12V AC/DC
TR-51726-**
24V AC/DC
TR-51728-**
240V AC
TR-51721-**
WATCHDOG
120V AC/DC
TR-51822-**
Power Trigger
12V AC/DC
TR-51826-**
(Retriggerable
24V AC/DC
TR-51828-**
DIAGRAM 4
Single Shot)
240V AC
TR-51821-**
" See Pages 32-33 for definitions & explanations of Timing Functions.
! 8 Pin SPDT versions of these functions are available−see Page 38.
Sockets & Accessories−Page 58
Dimensions−Page 37
Application Data−Page 37
Standard Modifications−Pages 50-51
Timing Ranges
** TIMING RANGE TABLE
COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE
FROM TABLE BELOW
i.e., TR-51622-04
Time Delay Range
0.02 - 2 Sec.
0.05 - 5 Sec.
0.1 - 10 Sec.
0.15 - 15 Sec.
0.3 - 30 Sec.
0.6 - 60 Sec.
1.2 - 120 Sec.
1.8 - 180 Sec.
3 - 300 Sec.
4.5 - 450 Sec.
Code
03
04
05
06
07
08
09
10
12
13
Time Delay Range Code
6 Sec. - 10 Min.
22
9 Sec. - 15 Min.
14
0.3 - 30 Min.
15
0.6 - 60 Min.
16
1.2 - 120 Min. 17
1.8 - 180 Min. 18
2.4 Min. - 4 Hr.
19
4.8 Min. - 8 Hr.
20
7.2 Min. - 12 Hr.
21
14.4 Min. - 24 Hr.
23
For Fixed Time Delay (at no additional charge), add suffix “F” and
time delay desired to basic Product Number, i.e., TR-51622-F5S
is an Off Delay with a time delay fixed at 5 seconds.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
35
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
Repeat Cycle & Delayed Inter
val
Interval
!
DUAL KNOB UNITS *
PRODUCT
INPUT
NUMBER **
COMPLETE PRODUCT
VOLTAGE
NUMBER USING 2 DIGIT CODE
Each unit has a single timing
range
!
FUNCTION "
Choose from 20 separate
timing ranges from
0.02 Seconds to 24 Hours
!
FROM TABLE BELOW
Independently adjustable ON
& OFF times on dual knob
timers
!
Uses industry-standard 8 or
11 pin octal sockets
!
10A DPDT output contacts
WIRING/
SOCKET
!
with
appropriate
socket
REPEAT CYCLE
(OFF Time First Followed
By ON Time
and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-53122-**
TR-53126-**
TR-53128-**
TR-53121-**
REPEAT CYCLE
(ON Time First Followed
By OFF Time
and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-55122-**
TR-55126-**
TR-55128-**
TR-55121-**
DELAYED INTERVAL
(OFF Time Followed by
ON Time Followed by OFF
State Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-56122-**
TR-56126-**
TR-56128-**
TR-56121-**
DELAYED INTERVAL
Control Switch Trigger
(OFF Time Followed by
ON Time Followed by OFF
State Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-56522-**
TR-56526-**
TR-56528-**
TR-56521-**
8 PIN OCTAL
70169-D
DIAGRAM 1
11 PIN OCTAL
70170-D
DIAGRAM 2
*
All Dual Knob units have independently selectable & adjustable ON & OFF times. To
order a Dual Knob unit with the same ON & OFF timing ranges, complete the Product
Number by adding one two-digit code from the table below, i.e., a TR-55122-08 is a
Repeat Cycle unit with both the ON time & OFF time adjustable between 0.6 - 60
seconds. To order a Dual Knob unit with different ON & OFF timing ranges, complete
the Product Number by adding two different two-digit codes from the table below. The
first suffix indicates the first timing range of the unit and the second suffix indicates the
second timing range, i.e., a TR-53122-05-12 is a Repeat Cycle unit with an OFF timing
range first of 0.1-10 seconds and an ON timing range second of 3-300 seconds.
" See Pages 32-33 for definitions & explanations of Timing Functions.
Sockets & Accessories−Page 58
Dimensions−Page 37
Application Data−Page 37
Standard Modifications−Pages 50-51
Timing Ranges
** TIMING RANGE TABLE
COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE
FROM TABLE BELOW
i.e., TR-55122-04
800-238-7474
www.macromatic.com
whats-up@macromatic.com
36
Time Delay Range
0.02 - 2 Sec.
0.05 - 5 Sec.
0.1 - 10 Sec.
0.15 - 15 Sec.
0.3 - 30 Sec.
0.6 - 60 Sec.
1.2 - 120 Sec.
1.8 - 180 Sec.
3 - 300 Sec.
4.5 - 450 Sec.
Code
03
04
05
06
07
08
09
10
12
13
Time Delay Range Code
6 Sec. - 10 Min.
22
9 Sec. - 15 Min.
14
0.3 - 30 Min.
15
0.6 - 60 Min.
16
1.2 - 120 Min. 17
1.8 - 180 Min. 18
2.4 Min. - 4 Hr.
19
4.8 Min. - 8 Hr.
20
7.2 Min. - 12 Hr.
21
14.4 Min. - 24 Hr.
23
For Fixed Time Delay (at no additional charge), add suffix “F”
and time delay desired to basic Product Number, i.e., TR-53122F5S is a Repeat Cycle with a time delay fixed at 5 seconds.
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
Application Data & Dimensions
Application Data
Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
DC Operation:
+10/-15% of nominal.
Load (Burden):
2 VA
Setting Accuracy:
Maximum Setting (Adjustable): +5%,
Minimum Setting (Adjustable): +0%,
Fixed Time Delay: > 2 Seconds
0.1 - 2 Seconds
-0%
-50%
+1%
+5%
Repeat Accuracy (constant voltage and temperature):
> 2 Seconds Delay
+0.1%
+2%
0.1 - 2 Seconds Delay
Reset Time:
On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds
Off Delay/Single Shot/Watchdog: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
0.05 Seconds
12, 24 & 48V units
0.08 Seconds
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Insulation Voltage:
2,000 volts
Output Contacts:
DPDT 10A @ 240V AC/28V DC,
1/2HP @ 240V AC, 1/3HP @ 120V AC
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
On all units triggered by input voltage or by a control switch, do
not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. On all units with a
power trigger, do not use a solid state switch with leakage
current exceeding 0.5ma. Contact Macromatic Controls for
additional information.
Triggering Off Delay, Single Shot or Watchdog Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time is
0.1 seconds.
Approvals:
File #E109466
File #LR45565
Temperature:
12-120V Input Voltage: -28o to 65oC (-18o to 150oF)
240V Input Voltage:
-28o to 50oC (-18o to 122oF)
Low Voltage &
EMC Directives
EN60947-1, EN60947-5-1
with
appropriate
socket
File #E109466
Dimensions
All Dimensions in
Inches (Millimeters)
2.4
(60)
2.9
(74)
1.7
(43)
3.5
(89)
37
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
8 Pin SPDT Versions
Off Delay
atchdog
Delay,, Single Shot & W
Watchdog
!
These are 8 pin 10A SPDT
versions of our standard 11
pin DPDT products
!
Each unit has a single timing
range from 0.02 Seconds to
24 Hours
!
Uses industry-standard 8 pin
octal socket
!
with
appropriate
socket
FUNCTION "
OFF DELAY
Control Switch Trigger
SINGLE SHOT
Control Switch Trigger
WATCHDOG
Control Switch Trigger
(Retriggerable
Single Shot)
OFF DELAY
Power Trigger
SINGLE SHOT
PowerTrigger
WATCHDOG
Power Trigger
(Retriggerable
Single Shot)
PRODUCT
NUMBER **
INPUT
VOLTAGE
COMPLETE PRODUCT
NUMBER USING 2 DIGIT CODE
FROM TABLE BELOW
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-51662-**
TR-51666-**
TR-51668-**
TR-51661-**
TR-51562-**
TR-51566-**
TR-51568-**
TR-51561-**
TR-51362-**
TR-51366-**
TR-51368-**
TR-51361-**
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-51962-**
TR-51966-**
TR-51968-**
TR-51961-**
TR-51762-**
TR-51766-**
TR-51768-**
TR-51761-**
TR-51862-**
TR-51866-**
TR-51868-**
TR-51861-**
WIRING/
SOCKETS !
8 PIN OCTAL
70169-D !
DIAGRAM 11
8 PIN OCTAL
70169-D !
DIAGRAM 37
" See Pages 32-33 for definitions & explanations of Timing Functions.
! Note: if these products are ordered with the Remote Adjust Potentiometer modification
(suffix -Rx), they will require an 11 pin octal socket−see Page 50 for more information.
Sockets & Accessories−Page 58
Dimensions−Page 39
Application Data−Page 39
Standard Modifications−Pages 50-51
Timing Ranges
** TIMING RANGE TABLE
COMPLETE PRODUCT NUMBER USING TWO DIGIT CODE
FROM TABLE BELOW
i.e., TR-51662-04
800-238-7474
www.macromatic.com
whats-up@macromatic.com
38
Time Delay Range
0.02 - 2 Sec.
0.05 - 5 Sec.
0.1 - 10 Sec.
0.15 - 15 Sec.
0.3 - 30 Sec.
0.6 - 60 Sec.
1.2 - 120 Sec.
1.8 - 180 Sec.
3 - 300 Sec.
4.5 - 450 Sec.
Code
03
04
05
06
07
08
09
10
12
13
Time Delay Range Code
6 Sec. - 10 Min.
22
9 Sec. - 15 Min.
14
0.3 - 30 Min.
15
0.6 - 60 Min.
16
1.2 - 120 Min. 17
1.8 - 180 Min. 18
2.4 Min. - 4 Hr.
19
4.8 Min. - 8 Hr.
20
7.2 Min. - 12 Hr.
21
14.4 Min. - 24 Hr.
23
For Fixed Time Delay (at no additional charge), add suffix “F” and
fixed time delay desired to basic Product Number,i.e.,
TR-51662-F5S is an Off Delay with a time delay fixed at 5 seconds.
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable Plug-in
8 Pin SPDT Versions
Application Data & Dimensions
Application Data
Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
DC Operation:
+10/-15% of nominal.
Load (Burden):
2 VA
Setting Accuracy:
Maximum Setting (Adjustable): +5%,
Minimum Setting (Adjustable): +0%,
Fixed Time Delay: > 2 Seconds
0.1 - 2 Seconds
-0%
-50%
+1%
+5%
Repeat Accuracy (constant voltage and temperature):
> 2 Seconds Delay
+0.1%
0.1 - 2 Seconds Delay
+2%
Reset Time:
Off Delay/Single Shot/Watchdog: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
0.05 Seconds
12, 24 & 48V units
0.08 Seconds
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Temperature:
12-120V Input Voltage: -28o to 65oC (-18o to 150oF)
240V Input Voltage:
-28o to 50oC (-18o to 122oF)
Insulation Voltage:
2,000 volts
Output Contacts:
DPDT 10A @ 240V AC/28V DC,
1/2HP @ 240V AC, 1/3HP @ 120V AC
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
On all units triggered by a control switch, do not use a solid
state switch to initiate the timing sequence-problems with
leakage current could occur. On all units with a power trigger,
do not use a solid state switch with leakage current exceeding
0.5ma. Contact Macromatic Controls for additional information.
Triggering Off Delay, Single Shot or Watchdog Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time is
0.1 seconds.
Approvals:
File #E109466
File #LR45565
Low Voltage &
EMC Directives
EN60947-1, EN60947-5-1
with
appropriate
socket
File #E109466
Dimensions
All Dimensions in
Inches (Millimeters)
2.4
(60)
2.9
(74)
1.7
(43)
3.5
(89)
39
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Programmable
Multi-Range Plug-in
On Delay
val On & Flasher
Delay,, Inter
Interval
!
Each unit has 16 timing
ranges built-in
!
Selecting a range is easy
using a rotary switch (no
math is required or DIP
switches to set)
!
Timing ranges up to 2 hours
!
Uses industry-standard 8 pin
octal sockets
!
10A DPDT output contacts
SINGLE KNOB UNITS
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60222
TR-60226
TR-60228
TR-60221
8 PIN OCTAL
70169-D
INTERVAL ON
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60522
TR-60526
TR-60528
TR-60521
FLASHER
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-60822
TR-60826
TR-60828
TR-60821
FUNCTION "
ON DELAY
!
with
appropriate
socket
DIAGRAM 1
" See Pages 32-33 for definitions & explanations of Timing Functions.
Sockets & Accessories−Page 58
Dimensions−Page 43
Application Data−Page 43
Standard Modifications−Pages 50-51
Timing Ranges
Select one of the 16 built-in time ranges by setting the rotary switch
per a chart on the unit and adjust within that range using the knob
on top:
SINGLE KNOB UNITS
800-238-7474
www.macromatic.com
whats-up@macromatic.com
40
Dial
Setting
Timing
Range
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
0.1 - 0.25 Sec.
0.2 - 0.5 Sec.
0.3 - 1 Sec.
0.5 - 2 Sec.
1 - 4 Sec.
2 - 8 Sec.
4 - 15 Sec.
8 - 30 Sec.
15 - 60 Sec.
30 - 120 Sec.
1 - 4 Min.
2 - 8 Min.
4 - 15 Min.
8 - 30 Min.
15 - 60 Min.
30 - 120 Min.
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Programmable
Multi-Range Plug-in
Off Delay
atchdog
Delay,, Single Shot & W
Watchdog
SINGLE KNOB UNITS
FUNCTION "
OFF DELAY
Control Switch Trigger
SINGLE SHOT
Control Switch Trigger
WATCHDOG
Control Switch Trigger
(Retriggerable
Single Shot)
OFF DELAY
Power Trigger
SINGLE SHOT
Power Trigger
WATCHDOG
Power Trigger
(Retriggerable
Single Shot)
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61622
TR-61626
TR-61628
TR-61621
TR-61522
TR-61526
TR-61528
TR-61521
TR-61322
TR-61326
TR-61328
TR-61321
11 PIN OCTAL
70170-D
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-61922
TR-61926
TR-61928
TR-61921
TR-61722
TR-61726
TR-61728
TR-61721
TR-61822
TR-61826
TR-61828
TR-61821
11 PIN OCTAL
70170-D
DIAGRAM 2
!
Each unit has 16 timing
ranges built-in
!
Selecting a range is easy
using a rotary switch (no
math is required or DIP
switches to set)
!
Timing ranges up to 2 hours
!
Uses industry-standard
11 pin octal sockets
!
10A DPDT output contacts
!
with
appropriate
socket
DIAGRAM 4
" See Pages 32-33 for definitions & explanations of Timing Functions.
Sockets & Accessories−Page 58
Dimensions−Page 43
Application Data−Page 43
Standard Modifications−Pages 50-51
Timing Ranges
Select one of the 16 built-in time ranges by setting the rotary switch
per a chart on the unit and adjust within that range using the knob
on top:
SINGLE KNOB UNITS
Dial
Setting
Timing
Range
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
0.1 - 0.25 Sec.
0.2 - 0.5 Sec.
0.3 - 1 Sec.
0.5 - 2 Sec.
1 - 4 Sec.
2 - 8 Sec.
4 - 15 Sec.
8 - 30 Sec.
15 - 60 Sec.
30 - 120 Sec.
1 - 4 Min.
2 - 8 Min.
4 - 15 Min.
8 - 30 Min.
15 - 60 Min.
30 - 120 Min.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
41
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Programmable
Multi-Range Plug-in
Repeat Cycle & Delayed Inter
val
Interval
!
Each unit has 16 timing
ranges built-in
!
Selecting a range is easy
using a rotary switch (no
math is required or DIP
switches to set)
!
Timing ranges up to 24
hours
!
Independently selectable &
adjustable ON & OFF times
on dual knob timers
!
Uses industry-standard 8 or
11 pin octal sockets
!
10A DPDT output contacts
!
with
appropriate
socket
DUAL KNOB UNITS *
FUNCTION "
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
REPEAT CYCLE
(OFF Time First Followed
By ON Time
and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-63122
TR-63126
TR-63128
TR-63121
8 PIN OCTAL
70169-D
REPEAT CYCLE
(ON Time First Followed
By OFF Time
and Repeating)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-65122
TR-65126
TR-65128
TR-65121
DELAYED INTERVAL
(OFF Time Followed by
ON Time Followed by OFF
State Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-66122
TR-66126
TR-66128
TR-66121
DELAYED INTERVAL
Control Switch Trigger
(OFF Time / ON Time /
OFF State Until Reset)
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TR-66522
TR-66526
TR-66528
TR-66521
DIAGRAM 1
11 PIN OCTAL
70170-D
DIAGRAM 2
* All Dual Knob units have independently selectable & adjustable ON & OFF times.
" See Pages 32-33 for definitions & explanations of Timing Functions.
Sockets & Accessories−Page 58
Dimensions−Page 43
Application Data−Page 43
Standard Modifications−Pages 50-51
Timing Ranges
Select one of the 16 built-in time ranges by setting the rotary switch
per a chart on the unit and adjust within that range using the knob
on top:
DUAL KNOB UNITS
800-238-7474
www.macromatic.com
whats-up@macromatic.com
42
Dial
Setting
Timing
Range
A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
0.6 - 2.5 Sec.
1.5 - 5 Sec.
2.5 - 10.5 Sec.
5 - 21 Sec.
10 - 42 Sec.
0.4 - 1.4 Min.
0.7 - 2.8 Min.
1.5 - 5.5 Min.
3 - 11 Min.
5.5 - 22.5 Min.
11 - 45 Min.
0.4 - 1.5 Hr.
0.8 - 3 Hr.
1.5 - 6 Hr.
3 - 12 Hr.
6 - 24 Hr.
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Programmable
Multi-Range Plug-in
Application Data & Dimensions
Application Data
Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
DC Operation:
+10/-15% of nominal.
Load (Burden):
2 VA
Setting Accuracy:
Maximum Setting (Adjustable): +5%,
Minimum Setting (Adjustable): +0%,
Fixed Time Delay: > 2 Seconds
0.1 - 2 Seconds
-0%
-50%
+1%
+5%
Repeat Accuracy (constant voltage and temperature):
> 2 Seconds Delay
+0.1%
0.1 - 2 Seconds Delay
+2%
Reset Time:
On Delay/Interval/Repeat Cycle/Delayed Interval: 0.1 Seconds
Off Delay/Single Shot/Watchdog: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
0.05 Seconds
12, 24 & 48V units
0.08 Seconds
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Insulation Voltage:
2,000 volts
Output Contacts:
DPDT 10A @ 240V AC/28V DC,
1/2HP @ 240V AC, 1/3HP @ 120V AC
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
On all units triggered by input voltage or by a control switch, do
not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. On all units with a
power trigger, do not use a solid state switch with leakage
current exceeding 0.5ma. Contact Macromatic Controls for
additional information.
Triggering Off Delay, Single Shot or Watchdog Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time is
0.1 seconds.
Approvals:
File #E109466
File #LR45565
Temperature:
12-120V Input Voltage: -28o to 65oC (-18o to 150oF)
240V Input Voltage:
-28o to 50oC (-18o to 122oF)
Low Voltage &
EMC Directives
EN60947-1, EN60947-5-1
with
appropriate
socket
File #E109466
Dimensions
All Dimensions in
Inches (Millimeters)
2.4
(60)
2.9
(74)
1.7
(43)
3.5
(89)
43
TIME DELA
Y RELA
YS
DELAY
RELAYS
Compact Non-Programmable
Plug-in
1.4 (36)
2.2 (56)
2.4 (61)
1.4
(36)
All Dimensions in
Inches (Millimeters)
!
Compact, economical design
with standard features for
basic applications
!
6 separate timing ranges
from 0.2 to 300 seconds
!
5A SPDT output contacts
!
Uses industry-standard 8 pin
octal sockets
FUNCTION "
PRODUCT
NUMBER **
INPUT
VOLTAGE
WIRING/
SOCKET#
COMPLETE PRODUCT
NUMBER USING 2 DIGIT CODE
FROM TABLE BELOW LEFT
ON DELAY
120V AC
12V AC/DC
24V AC/DC
SS-6262-**
SS-6266-**
SS-6268-**
INTERVAL ON
120V AC
12V AC/DC
24V AC/DC
SS-8062-**
SS-8066-**
SS-8068-**
OFF DELAY
120V AC
12V AC/DC
24V AC/DC
SS-8562-**
SS-8566-**
SS-8568-**
SINGLE SHOT
120V AC
12V AC/DC
24V AC/DC
SS-8762-**
SS-8766-**
SS-8768-**
8 Pin Octal
70169-D
!
DIAGRAM 5
with appropriate socket
Timing Ranges
** TIMING RANGE TABLE
COMPLETE PRODUCT NUMBER USING
TWO DIGIT CODE FROM TABLE BELOW
i.e., SS-6262-04
Time Delay Range
0.2 - 5 Sec.
0.5 - 15 Sec.
1 - 30 Sec.
2 - 60 Sec.
6 - 180 Sec.
10 - 300 Sec.
Code
04
06
07
08
10
12
For Fixed Time Delay: (at no additional
charge), add suffix “F” and time delay
desired to basic Product Number, i.e.,
SS-6262-F5S is an On Delay fixed at 5
seconds.
DIAGRAM 6
" See Pages 32-33 for definitions & explanations of Timing Functions.
# See Page 58 for Sockets & Accessories.
Application Data
Voltage Tolerance:
AC Operation: +10/-15% of nominal at 50/60 Hz.
DC Operation: +10/-15% of nominal.
Load (Burden):
Less than 3 VA
Setting Accuracy:
Maximum Setting: +10%, -0%
Minimum Setting: +0%, -50%
Fixed Time Delay: > 2 Seconds
0.1 - 2 Seconds
Repeat Accuracy:
> 2 Seconds Delay
0.1 - 2 Seconds Delay
800-238-7474
www.macromatic.com
whats-up@macromatic.com
44
8 Pin Octal
70169-D
Reset Time:
0.2 Seconds
+2%
+5%
+2%
+5%
Temperature:
0o to 60oC (32o to 140oF)
Compatibility:
Do not use a solid state switch to
initiate the timing sequence-problems
with leakage current could occur.
Contact Macromatic Controls for
additional information.
Transient Protection:
10,000 volts for 20 microseconds
Output Contacts:
SPDT 5A Resistive @ 120V AC/
28V DC, 1/6HP @ 120VAC
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Triggering Off Delay & Single Shot Units:
Timing sequence must be initiated only after input Approvals:
power is applied to unit. Minimum required
File #E109466
trigger switch closure time is 0.1 seconds.
with appropriate
socket
TIME DELA
Y RELA
YS
DELAY
RELAYS
Non-Programmable with
Quick Connect Terminals
2.4 (60)
2.9
(74)
1.7
(43)
3.5
(89)
All Dimensions in
Inches (Millimeters)
FUNCTION "
ON DELAY
INPUT
VOLTAGE
TIME DELAY
RANGE
PRODUCT
NUMBER
WIRING/
SOCKET#
!
Industry-standard .187" quick
connect terminals
120V AC/DC
0.1-10 Sec.
1-180 Sec.
3-300 Sec.
SS-40222-05
SS-40222-10
SS-40222-12
.187” Quick Connect
70171-D
!
On Delay or Off Delay timing
functions
!
3 separate timing ranges up
to 300 seconds
0.1-10 Sec.
1-180 Sec.
3-300 Sec.
SS-40228-05
SS-40228-10
SS-40228-12
!
12A DPDT output contacts
24V AC/DC
!
DIAGRAM 25
OFF DELAY
120V AC/DC
0.1-10 Sec.
1-180 Sec.
3-300 Sec.
SS-41622-05
SS-41622-10
SS-41622-12
24V AC/DC
0.1-10 Sec.
1-180 Sec.
3-300 Sec.
SS-41628-05
SS-41628-10
SS-41628-12
.187” Quick Connect
70171-D
with appropriate
socket
DIAGRAM 26
" See Pages 32-33 for definitions & explanations of Timing Functions.
# See Page 58 for Sockets & Accessories
For Fixed Time Delay: (at no additional charge), add letter "F" and time delay desired to basic
Product Number, i.e., SS-40222-F5S, is an On Delay with time delay fixed at 5 seconds.
Application Data
Voltage Tolerance:
Triggering Off Delay Timers:
AC Operation: +10/-15% of nominal at 50/60 Hz. Timing sequence must be initiated only
DC Operation: +10/-15% of nominal.
after input power is applied to unit.
Minimum required trigger switch closure
Load (Burden):
time is 0.1 seconds.
Less than 3 VA.
Transient Protection:
Setting Accuracy:
10,000 volts for 20 microseconds
Maximum Setting: +10%, -0%
Minimum Setting: +0%, -50%
Output Contacts:
Fixed Time Delay: > 2 Seconds
+2%
DPDT 12A Resistive @ 240V AC/
0.1 - 2 Seconds +5%
30V DC, 1/2HP @240VAC
Repeat Accuracy:
> 2 Seconds Delay
0.1 - 2 Seconds Delay
+2%
+5%
Life:
Mechanical: 10,000,000 operations
Full Load: 30,000 operations
Compatibility:
Approvals:
On Off Delay units, do not use a solid state
switch to initiate the timing sequence-problems
with leakage current could occur. Contact
File
#E109466
Macromatic Controls for additional information.
Recycle Time: 0.1 Seconds
Temperature: -28o to 65oC (-20o to 150oF)
File
#LR45565
Low Voltage &
EMC Directives
EN60947-1,
EN60947-5-1
800-238-7474
www.macromatic.com
with appropriate
socket
whats-up@macromatic.com
45
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Digital-Set
Programmable Multi-Range
Plug-in
Multi-Function
!
Available in either SingleFunction or Multi-Function
versions (with five userselectable modes)
!
Pushbutton Thumbwheels
for digital set of time delay &
function (TD-781 series only)
!
50ms - 999 hour programmable time range
!
Uses industry-standard 8 or
11 pin octal sockets
!
10A DPDT output contacts
!
LED indicates timing mode
and time out conditions
!
Single-Function
The TD-7 series of time delay relays offer an easy and accurate way to select any time
delay between 50ms & 999 hours. Programming is accomplished by using a pushbutton
thumbwheel to select one of seven built-in time ranges and three pushbutton thumbwheels
to digitally set the time delay required. This method provides a greater setting accuracy
than is found on other units with an analog potentiometer. An LED indicates timing mode
and time out condition.
The TD-7 series comes in two versions: a single function product or a multi-function
product. The TD-781 multi-function unit has a fifth pushbutton thumbwheel to select one of
five built-in functions.
Multi-Function Product
FUNCTION
MULTI-FUNCTION
(5 Field-Selectable
Functions in one unit)
! On Delay
! Off Delay
! Interval On
! Single Shot
! Flasher
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-78122
TD-78126
TD-78128
TD-78121
11 PIN OCTAL
70170-D
with
appropriate
socket
DIAGRAM 121
Single Function Products
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-70222
TD-70226
TD-70228
TD-70221
8 PIN OCTAL
70169-D
INTERVAL ON
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-70522
TD-70526
TD-70528
TD-70521
FLASHER
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-70822
TD-70826
TD-70828
TD-70821
OFF DELAY
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-71622
TD-71626
TD-71628
TD-71621
SINGLE SHOT
120V AC/DC
12V AC/DC
24V AC/DC
240V AC
TD-71522
TD-71526
TD-71528
TD-71521
FUNCTION
ON DELAY
DIAGRAM 1
11 PIN OCTAL
70170-D
800-238-7474
DIAGRAM 2
www.macromatic.com
whats-up@macromatic.com
46
Sockets & Accessories−Page 58
Dimensions−Page 47
Application Data−Page 47
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM Digital-Set
Programmable Multi-Range Plug-in
Application Data & Dimensions
Application Data
Voltage Tolerance:
AC Operation:
+10/-15% of nominal at 50/60 Hz.
DC Operation:
+10/-15% of nominal.
Load (Burden):
3 VA
Setting Accuracy:
+1% of set time or +50ms, whichever is greater.
Repeat Accuracy (constant voltage and temperature):
+0.1% of set time or +0.02 seconds, whichever is greater.
Reset Time:
On Delay/Interval/Flasher: 0.1 Seconds
Off Delay/Single Shot: 0.04 Seconds
Start-up Time:
(Time from when power is applied until unit is timing)
120 & 240V units
0.05 Seconds
12, 24 & 48V units
0.08 Seconds
Maintain Function Time:
(Time unit continues to time after power is removed)
0.01 Seconds for all units
Temperature:
12-120V Input Voltage: -28o to 65oC (-18o to 150oF)
240V Input Voltage:
-28o to 50oC (-18o to 122oF)
Output Contacts:
DPDT 10A @ 240V AC/28V DC,
1/2HP @ 240V AC, 1/3HP @ 120V AC
B300 & R300; AC15 & DC13
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Compatibility:
Do not use a solid state switch to initiate the timing sequenceproblems with leakage current could occur. Contact Macromatic Controls for additional information.
Triggering Off Delay or Single Shot Units:
Timing sequence must be initiated only after input voltage is
applied to unit. Minimum required trigger switch closure time is
0.1 seconds.
LED:
Flasher Mode:
Flashes during “ON” time; continuous on
during “OFF” time
All Other Modes: Flashes during timing; continuous on after
time out.
Approvals:
File #E109466
Insulation Voltage:
2,000 volts
File #LR45565
Low Voltage &
EMC Directives
EN60947-1, EN60947-5-1
with
appropriate
socket
File #E109466
Dimensions
All Dimensions in
Inches (Millimeters)
2.4
(60)
2.9
(74)
1.7
(43)
3.0
(77)
47
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger TM III
Digital-Set
Multi-Function
Multi-Range
All dimensions are inches
(millimeters)
! 8 field-selectable functions in
one unit
! Push-button thumbwheels for
digital-setting of time delay
! Universal AC/DC input
voltage
! LCD display
! 0.1 Second to 9,990 Hours
programmable timing range
! Panel, track or surface
mounting
! 1/16 DIN style case
! 3A SPDT output contacts
FUNCTION
INPUT
VOLTAGE
PRODUCT
NUMBER
WIRING/
SOCKETS"
8 FIELDSELECTABLE
FUNCTIONS!
24-240V AC 50/60Hz
& 12-240V DC
9816U1
SEE DIAGRAMS
ON PAGE 49
11 Pin Octal
! Functions Include: On Delay, Flasher, Interval/Off Delay, Off Delay (2 Versions), Interval,
Delayed Interval and On Delay/Off Delay (see Page 49 for Further Details)
" See below for Sockets & Accessories.
Application Data
Voltage Tolerance:
+10% of rated voltage.
Temperature:
-10o to 55oC (14o to 131oF)
Load (Burden):
Less than 3 VA
Output Contacts:
SPDT 3A Resistive @ 250V AC
SPDT 5A Resistive @ 28V DC
Repeat Accuracy:
+0.3%, +0.05 seconds (includes variation
due to voltage and temperature changes).
Setting Accuracy:
+0.5%, +0.05 seconds maximum.
!
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
Approvals:
Recycle Time:
0.5 seconds maximum.
File #E170213
File #LR701134
○
○
○
○
○
○
DESCRIPTION
11 Pin Octal Socket (Surface or Track Mounting)
11 Pin Octal Socket (Back Mounting)
Panel Mounting Adaptor
Protective Cover
" See Page 58
○
○
○
Sockets & Accessories
PRODUCT
NUMBER
70170-D"
70300
70310
70320
PANEL CUTOUT
70300
70310
800-238-7474
www.macromatic.com
whats-up@macromatic.com
48
70320
All Dimensions in
Inches
(Millimeters)
TIME DELA
Y RELA
YS
DELAY
RELAYS
Time Ranger
FUNCTION
MODE A
○
○
○
○
MODE B
○
○
○
○
○
○
○
○
Standard
(Diagram 7)
○
○
Flasher
○
○
○
○
○
○
○
○
○
○
○
○
TIMING CHART
Upon application of control power, the preset time begins. At the end of the preset time,
the relay contacts transfer. Control power must be removed and reapplied to reset the time
delay relay.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Triggered
(Diagram 9)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure of the Start switch, the preset time begins. At the end of the preset time, the
relay contacts transfer. Any closure of the Start switch is ignored until reset. The time
delay relay is reset by closing the Reset switch or removing the control power.
Standard
(Diagram 7)
Upon application of control power, the preset time begins. At the end of the preset time,
the relay contacts transfer and remain in that condition for the preset time. At the end of
this time, the relay contacts return to their normal condition and the sequence repeats until
control power is removed.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Triggered
(Diagram 9)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure of the Start switch, the preset time begins. At the end of the preset time, the
relay contacts transfer and remain in that condition for the preset time. At the end of this
time, the relay contacts return to their normal condition and the sequence repeats until the
Reset switch is closed or control power is removed.
MODE C
Interval/
Off-Delay
(Diagram 8)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure or opening of the Start switch, the relay contacts transfer and the preset time
begins. At the end of the preset time, the relay contacts return to their normal condition.
Any closure or opening of the Start switch during timing causes the time to reset.
MODE D
Off-Delay (I)
(Diagram 8)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure of the Start switch, the relay contacts transfer and hold. Upon release of the
Start switch, the preset time begins. At the end of the preset time, the relay contacts return
to their normal condition. Any application of the Start switch will reset the time.
MODE E
Interval
Standard
(Diagram 7)
Upon application of control power, the relay contacts transfer and the preset time begins.
At the end of the preset time, the contacts return to their normal condition. Control power
must be removed and reapplied to reset the time delay relay.
○
○
○
○
MODE F
○
○
III Digital-Set Multi-Function
Multi-Range
OPERATION
On-Delay
○
TM
○
○
○
○
○
○
○
○
○
Delayed
Interval
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Triggered
(Diagram 9)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure of the Start switch, the relay contacts transfer and the preset time begins. At
the end of the preset time, the contacts return to their normal condition. Any closure of the
Start switch is ignored until reset. The time delay relay is reset by closing the Reset switch
or removing the control power.
Standard
(Diagram 7)
Upon application of control power, the preset time begins. At the end of the preset time,
the relay contacts transfer and remain in that condition for the preset time. At the end of this
time, the relay contacts return to their normal condition and the sequence stops. Power
must be removed and reapplied to reset the time delay relay.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Triggered
(Diagram 9)
Upon application of control power, the time delay relay is ready to accept trigger signals. At
the end of the preset time, the relay contacts transfer and remain in that condition for the
preset time. At the end of this time, the relay contacts return to their normal condition and
the sequence stops. Power must be removed and reapplied to reset the time delay relay.
MODE G
On-Delay/
Off-Delay
(Diagram 8)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Upon closure of the Start switch, the preset time begins. At the end of the preset time, the
relay contacts will transfer. Upon opening of the Start switch, the preset time begins. At
the end of the preset time, the output contacts return to their normal condition.
MODE H
Off-Delay (II) (Diagram 8)
Upon application of control power, the time delay relay is ready to accept trigger signals.
Closure of the Start switch is ignored. Upon release of the Start switch, the relay contacts
transfer and the preset time begins. At the end of the preset time, the relay contacts return
to their normal condition. Opening the Start switch during timing resets the time.
DIAGRAM 7
DIAGRAM 8
DIAGRAM 9
49
TIME DELA
Y RELA
YS
DELAY
RELAYS
Standard Modifications
All of our Catalog-Listed Time Delay Relays can be adapted for different applications. Below is a list of various Situations, Solutions and Ordering Information to illustrate many of these modifications. Please contact Macromatic if you
have any questions or need additional information before ordering any products with these modifications.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Solution: Macromatic can build a time
delay relay triggered by a control switch
(i.e., Off Delay, Single Shot, Watchdog)
with any pin configuration required to
meet your application.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
50
Normal 11 pin product with
configuration for Remote
Adjust (2-6 Control Switch)
○
○
○
○
○
○
○
○
○
○
○
○
○
To order: Any time delay relay with a
remote adjustment feature and an 11
pin header, use the following chart to
determine which suffix matches the
value of the remote potentiometer, i.e.,
a TR-50222-04R6 is an On Delay with
an 11 pin header, setup for a 750K
remote potentiometer to be connected
to pins 5 & 7:
Remote Pot Add Remote Pot
Value
Suffix
Value
250K
R3
1.5M
300K
R4
2M
500K **
R5
2.5M
750K
R6
5M
1M
R7
○
○
○
○
○
Normal 8 pin product
with 11 pin configuration for Remote Adjust
○
○
○
○
○
Solution: Macromatic can build most
time delay relays with an optional remote
adjustment feature. The potentiometer
usually supplied with the product is
removed, and the product is setup for
use with a customer-supplied remote
potentiometer to be connected to pins 5
& 7. Units that are normally 8 pin will
have an 11 pin configuration. Units that
are normally 11 pin will have the control
switch connected between pins 2 & 6
(instead of the standard 5 & 6). For other
control switch pin configurations, contact
Macromatic for ordering information.
○
Situation B: I need to replace a time
delay relay that is already connected to a
remote potentiometer with a known
value.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Situation A: I want to mount a time
delay relay in an enclosure, but would
like to adjust the time delay from outside
the enclosure instead of having to open
the door.
○
* NOTE: These suffixes apply only to
different control switch pin configuations.
The input voltage and output pin configurations remain as shown at left. For other
configurations, contact Macromatic.
NOTE: The configuration of the input voltage
and output contacts has not been changed.
○
○
Standard 11 pin modified
with a 6-10 control switch
(Suffix T8)
○
Standard 11 pin time
delay relay, i.e., Off
Delay, Single Shot, or
Watchdog
○
Control
Control
Switch
Switch
Connected Add Connected Add
To Pins Suffix * To Pins Suffx *
2-5
T1
5-10
T6
2-6
T2
6-7
T7
2-7
T3
6-10
T8
5-7
T5
7-10
T9
○
Standard 11 pin modified
with a 2-6 control switch
(Suffix T2)
○
To order: Any time delay relay with a
special control switch configuration, use
the following chart to determine which
suffix provides the correct configuration
needed, i.e., a TR-51522-05T9 is a
Single Shot with the control switch
between pins 7 & 10 instead of 5 & 6:
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Situation: I have an 11 pin time delay
relay where all the pins match the wiring
diagram shown in your catalog (and
below) except the control switch (trigger
switch) is connected to pins other than
pins 5 and 6.
To order: Any time delay relay fixed at
a factory set delay time, replace the
normal two digit suffix indicating
adjustable time range with the suffix
Fxxt where xx is the specific time delay
desired and t is the time interval
(seconds, minutes or hours), i.e., a
TR-51622-F10S is an Off Delay fixed at
10 Seconds.
○
○
Solution: Macromatic offers products
where the adjustment potentiometer is
removed and the unit comes with one
specific (non-adjustable) time range, i.e.,
5 seconds, 1 minute, etc. These are
products with a “fixed” time delay.
○
Situation: I know exactly what time
delay I need and therefore, do not need
a unit with an adjustable time range.
Add
Suffix
R8
R9
R10
R11
** NOTE: A 500K potentiometer (R5) is the
only value that can be used with a Time
Ranger Programmable Time Delay Relay
(those catalog numbers that begin with a
TR-6).
TIME DELA
Y RELA
YS
DELAY
RELAYS
Standard Modifications
Situation: I want to use an 8 pin socket,
but according to your catalog, the time
delay relay I have selected is an 11 pin
unit.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Solution: Macromatic can build any TR
Series time delay relay that is normally
an 11 pin product with an 8 pin base.
This modified product will be SPDT only
instead of the normal DPDT of the 11 pin
version.
○
Situation: I have an 11 pin socket in
place and wired, but according to your
catalog, the time delay relay I want to
use is an 8 pin unit.
○
○
○
11 Pin DPDT
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Situation: I need the time delay relay to
recycle faster than the factory standard
of 0.1 seconds.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
8 Pin SPDT
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Special 11 Pin DPDT
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
To order: Any time delay relay with a
fast reset time, add the suffix N to the
end of the Product Number, i.e., a
TR-60222-N is an programmable On
Delay with a fast reset time of 0.05
seconds.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
To order: Any single knob programmable Time Ranger time delay relay
with a 24 hour time range, add the suffix
U to the end of the Product Number, i.e.,
a TR-60222-U would be an On Delay
with a programmable time range of 0.6
seconds - 24 hours.
Solution: Macromatic can modify our
single knob programmable Time Ranger
products that normally come with a 2
hour maximum setting to have a range of
0.6 seconds to 24 hours (same as our
dual knob units).
Situation: I have a power triggered time
delay relay (Off Delay, Single Shot or
Watchdog) with 120VAC input voltage,
but would like to trigger it with a 5VDC
computer generated voltage.
○
To order: Any standard 8 Pin time
delay relay modified to an 11 Pin base,
add the suffix H to the end of the
Product Number, i.e., a TR-60222-H is a
programmable On Delay time delay
relay with an 11 pin base configured as
shown at left.
Solution: A time delay relay with a fast
reset of 0.05 seconds is available.
Situation: I need a longer time delay
range than the 2 hour maximum available on the Macromatic programmable
Time Ranger single knob functions, i.e.,
On Delay, Interval On, Off Delay, etc.
○
○
Solution: Macromatic can build any
time delay relay that is normally an 8 pin
product with an 11 pin base.
Standard 8 Pin DPDT
○
○
To order: See Page 38 for ordering
information. NOTE: this option is
available on TR Series products only.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
To order: Any time delay relay with a
special power trigger voltage, use the
following chart to determine which suffix
provides the correct power trigger
voltage, i.e., a TR-51922-05TV05 is a
Power Triggered Off Delay with 120V
input voltage and a 5V trigger voltage:
Voltage Input
Add
Needed (AC/DC)
Suffix
5
TV05
12
TV12
24
TV24
120
TV120
Other
Call Macromatic
○
○
○
○
○
○
○
○
○
○
Solution: As standard, power triggered
time delay relays must use the same
voltage for both input voltage & trigger
voltage. However, Macromatic offers an
option on any power triggered unit to
have a voltage different than the input
voltage.
Normal Power Trigger
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
Situation: The control switch used to
initiate a time delay relay is a great
distance from the product and I am
experiencing problems triggering the
relay.
○
○
○
○
○
○
○
○
○
○
○
Special Power Trigger
○
○
○
○
○
○
○
○
○
○
○
○
Solution: Macromatic offers a long
distance control switch option. This
option will minimize the problems relating
to noise that could caused false triggering of the time delay relay.
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
○
To order: Any time delay relay with a
long distance control switch option, add
the suffix Y to the end of the Product
Number, i.e., a TR-61622-Y is a
programmable Off Delay with a long
distance control switch.
51
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 1 Switch Applications
SPDT or DPDT
!
For duplex loads
!
Works with 1 Control Switch
!
Control voltages of 12, 24,
120 & 240V AC
!
Compact plug-in design
utilizing industry-standard 8
or 11 pin octal socket
!
10A SPDT or DPDT Output
Configuration
!
Optional low profile selector
switch to lock in one sequence
!
2 LED’s indicate relay status
!
with appropriate
socket
Alternating Relays are used in special applications where the optimization of load
usage is required by equalizing the run time of two loads. They are also used
where additional capacity is required in case of excess load requirements. This
alternating action is initiated by a control switch, such as a float switch, manual
switch, timing relay, pressure switch, or other isolated contact. Each time the
initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay.
The Alternating Relays listed on this page are used with one control switch &
available in either SPDT or DPDT output configurations. See "Typical Installations"
on Page 53 for more information. For products with DPDT Cross-Wired output
configurations to be used with one or two control switches (LEAD-LAG), see Page
54.
Each version is available with an optional three position selector switch. This
allows the unit to alternate the two loads as normal, or lock the relay to one load or
the other. By locking the Alternating Relay to one load, the other load can be
removed for service without rewiring the first load for continuous operation. The
selector switch has a low profile to prevent any accidental changes in status.
OUTPUT
CONTACTS
SPDT
w/o Selector Switch
SPDT
w/ Selector Switch
DPDT
w/o Selector Switch
DPDT
w/ Selector Switch
CONTROL
VOLTAGE
PRODUCT
NUMBER
12V AC
24V AC
120V AC
240V AC
ARP012A6
ARP024A6
ARP120A6
ARP240A6
8 Pin Octal
70169-D
12V AC
24V AC
120V AC
240V AC
ARP012A6R
ARP024A6R
ARP120A6R
ARP240A6R
DIAGRAM 17
12V AC
24V AC
120V AC
240V AC
ARP012A2
ARP024A2
ARP120A2
ARP240A2
11 Pin Octal
70170-D
12V AC
24V AC
120V AC
240V AC
ARP012A2R
ARP024A2R
ARP120A2R
ARP240A2R
DIAGRAM 18
" See Page 58 for Sockets & Accessories.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
52
WIRING/SOCKET"
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 1 Switch Applications
Application Data & Dimensions
Application Data
Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz.
Transient Protection: 10,000 volts for 20 microseconds
Load (Burden): Less than 3VA
Indicator LED's: 2 LED's marked LOAD A and LOAD B
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC
Optional Selector Switch Settings:
ALTERNATE
LOCK LOAD A
LOCK LOAD B
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
o
o
o
Approvals:
o
Temperature: -28 to 65 C (-20 to 150 F)
File #E109466
File #LR45565
File #E109466
with
appropriate
socket
Dimensions
2.4 (60)
All Dimensions in
Inches (Millimeters)
2.9
(74)
3.1
(79)
1.7
(43)
Typical Installations
The loads in the following examples could be pumps, compressors,
or air conditioning/refrigeration units:
SPDT & DPDT
In the off state, the Control Switch is open, the Alternating
Relay is in the LOAD A position, and both loads (M1 & M2) are
off. When the Control Switch closes, it energizes the first load
(M1). The red LED marked “LOAD A” glows. As long as the
Control Switch remains closed, M1 remains energized. When
the Control Switch opens, the first load (M1) is turned off and
the Alternating Relay toggles to the LOAD B position. When
the Control Switch closes again, it energizes the second load
(M2). The red LED marked “LOAD B” glows. When the
Control Switch opens, the second load (M2) is turned off, the
Alternating Relay toggles back to the LOAD A position, and the
process can be repeated again. On relays with DPDT contacts,
two pilot lights can be used for remote indication of LOAD A or
LOAD B status.
SPDT
DPDT
53
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 2 Switch (Lead-Lag) Applications
DPDT Cross-Wired
!
For duplex loads
!
Works with 2 Control
Switches--LEAD & LAG
!
Control voltages of 12, 24,
120 & 240V AC
!
Compact plug-in design
utilizing industry-standard
8 pin octal socket
!
10A DPDT Cross-Wired
Output Configuration for
Lead-Lag Switches
!
Optional low profile selector
switch to lock in one sequence
!
2 LED’s indicate relay status
!
with appropriate
socket
Alternating Relays are used in special applications where the optimization of load
usage is required by equalizing the run time of two loads. They are also used
where additional capacity is required in case of excess load requirements. This
alternating action is initiated by a control switch, such as a float switch, manual
switch, timing relay, pressure switch, or other isolated contact. Each time the
initiating switch is opened, the output relay contacts will change state, thus alternating the two loads. Two LED indicators show the status of the output relay.
The Alternating Relays listed on this page are available in DPDT Cross-Wired
output configurations for use with one or two control switches (LEAD & LAG). See
"Typical Installations" on Page 55 for more information. For a special version of a
DPDT cross-wired unit to work with three control switches (LEAD, LAG & STOP),
see page 56. For products with SPDT or DPDT output configurations to be used
with one control switch, see Page 52.
Each version is available with an optional three position selector switch. This
allows the unit to alternate the two loads as normal, or lock the relay to one load or
the other. By locking the Alternating Relay to one load, the other load can be
removed for service without rewiring the first load for continuous operation. The
selector switch has a low profile to prevent any accidental changes in status.
OUTPUT
CONTACTS
DPDT CROSSWIRED
w/o Selector Switch
DPDT CROSSWIRED
w/ Selector Switch
CONTROL
VOLTAGE
PRODUCT
NUMBER
12V AC
24V AC
120V AC
240V AC
ARP012A3
ARP024A3
ARP120A3
ARP240A3
12V AC
24V AC
120V AC
240V AC
ARP012A3R
ARP024A3R
ARP120A3R
ARP240A3R
WIRING/SOCKET"
8 Pin Octal
70169-D
DIAGRAM 19
" See Page 58 for Sockets & Accessories.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
54
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 2 Switch (Lead-Lag) Applications
Application Data & Dimensions
Application Data
Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz.
Transient Protection: 10,000 volts for 20 microseconds
Load (Burden): Less than 3VA
Indicator LED's: 2 LED's marked LOAD A and LOAD B
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC
Optional Selector Switch Settings:
ALTERNATE
LOCK LOAD A
LOCK LOAD B
Life:
Mechanical: 10,000,000 operations
Full Load: 100,000 operations
o
o
o
Approvals:
o
Temperature: -28 to 65 C (-20 to 150 F)
File #E109466
File #LR45565
File #E109466
with
appropriate
socket
Dimensions
2.4 (60)
2.9
(74)
3.1
(79)
1.7
(43)
All Dimensions in
Inches (Millimeters)
Typical Installations
The loads in the following examples could be pumps, compressors,
or air conditioning/refrigeration units:
DPDT Cross-Wired
In the off state, both the Lead Control Switch and the Lag Control
Switch are open, the Alternating Relay is in the LOAD A position, and
both loads are off. When the Lead Control Switch closes, it energizes
the first load (M1). The red LED marked “LOAD A” glows. As long as
the Lead Control Switch remains closed, M1 remains energized. If
the Lag Control Switch closes, it energizes the second load (M2).
When the Lag Control Switch opens, the second load (M2) is turned
off. When the Lead Control Switch opens, the first load (M1) is
turned off and the Alternating Relay toggles to the LOAD B position.
When the Lead Control Switch closes, it turns on the second load
(M2). The red LED marked “LOAD B” glows. If the Lag Control
Switch closes, it will energize the first load (M1). When the Lag
Control Switch opens, the first load (M1) is turned off. When the Lead
Control Switch opens, the second load (M2) is turned off, the Alternating Relay toggles back to the LOAD A position, and the process can
be repeated again. NOTE: if the Lag Control Switch does not close
while the Lead Control Switch is closed, the Alternating Relay will act
as a normal unit.
55
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 3 Switch Applications
(Lead-Lag-Stop)
Sequence On-Simultaneous OFF
!
Works with 3 Control
Switches - LEAD, LAG and
STOP
!
Utilizes Sequence On Simultaneously Off
(S.O.S.O.) Operation
!
Replaces Separate Components in Duplex Panel,
Saving Space and Reducing
Labor
!
Protects against Failures of
Both STOP & LEAD
Switches
!
Control Voltages of 12, 24,
120 & 240V AC
!
Compact Plug-in Design
Utilizing Industry-Standard 8
Pin Octal Socket
!
Optional low profile selector
switch to lock in one sequence
!
2 LED’s indicate relay status
!
with appropriate
socket
Macromatic Alternating Relays for Three Switch Applications offer a number of
unique advantages over standard duplex units:
#
#
#
#
Combines standard DPDT cross-wired Alternating Relay, contactor auxiliary
contacts and control relay into one compact & economical product, thus
reducing the cost of the panel by saving space, reducing the number of
components and minimizing assembly labor.
Works with three switches instead of just one or two − LEAD, LAG and STOP.
Sequence On - Simultaneous Off (S.O.S.O.) Operation − the two loads are
energized sequentially, but remain on together until the STOP switch is
opened.
Protects against failure of the STOP and LEAD switches − if both switches fail,
the two pump motors will be energized simultaneously when the LAG switch is
closed.
See "Typical Installations" on Page 57 for more information.
Alternating Relays from Macromatic are available with an optional three position
selector switch. This allows the unit to alternate the two loads as normal, or lock
the relay to one load or the other. By locking the Alternating Relay to one load, the
other load can be removed for service without rewiring the first load for continuous
operation. The selector switch has a low profile to prevent any accidental changes
in status.
OUTPUT
CONTACTS
DPDT CROSSWIRED
For 3 Switch Operation
w/o Selector Switch
DPDT CROSSWIRED
For 3 Switch Operation
w/ Selector Switch
CONTROL
VOLTAGE PRODUCT NUMBER
12V AC
24V AC
120V AC
240V AC
ARP012A8
ARP024A8
ARP120A8
ARP240A8
12V AC
24V AC
120V AC
240V AC
ARP012A8R
ARP024A8R
ARP120A8R
ARP240A8R
WIRING/SOCKET"
8 Pin Octal
70169-D
DIAGRAM 58
" See Page 58 for Sockets & Accessories.
800-238-7474
www.macromatic.com
whats-up@macromatic.com
56
AL
TERNA
TING RELA
YS
ALTERNA
TERNATING
RELAYS
For 3 Switch Applications
Application Data & Dimensions
Dimensions
Application Data
Voltage Tolerances: +10%/-15% of control voltage at 50/60Hz.
Load (Burden): Less than 3VA
Output Contacts:
10A Resistive @ 240V AC/30V DC, 1/2HP @ 240V AC
2.4 (60)
Life:
Mechanical: 10,000,000 operations
Full Load: 150,000 operations
Temperature: -28o to 65oC (-20o to 150oF)
Transient Protection: 10,000 volts for 20 microseconds
2.9 (74)
1.7
(43)
3.1 (79)
Indicator LED's: 2 LED's marked LOAD A and LOAD B
Optional Selector Switch Settings:
ALTERNATE
LOCK LOAD A
LOCK LOAD B
Approvals:
All Dimensions in
Inches (Millimeters)
with
appropriate
socket
File #E109466
File #E109466
Typical Installations
DPDT Cross-Wired for Three Switch Applications
In the OFF state, all three switches are open, the
Alternating Relay is in the LOAD A position, and both
loads are off. No action happens with the Alternating
Relay or either load when the STOP Switch closes.
When the LEAD Switch closes, Load #1 (M1) turns on.
When the LAG Switch closes, Load #2 (M2) turns on.
Both loads remain on as long as all three switches are
closed.
When the LAG Switch opens, Load #2 (M2) remains on
because the STOP Switch is still closed. When the
LEAD Switch opens, Load #1 (M1) remains on because
the STOP Switch is still closed. When the STOP Switch
opens, both Load #1 (M1) and Load #2 (M2) are turned
off simultaneously. The Alternating Relay toggles to the
LOAD B position. The entire cycle is then repeated, but
with Load #2 (M2) energized first followed by Load #1
(M1).
This type of operation is known as “Sequence On Simultaneously Off (S.O.S.O.)”-the two loads are
energized sequentially, but remain on together until the
STOP switch is opened.
If both the STOP Switch and LEAD Switch fail to close
and turn on the first load, both loads will be turned on
simultaneously when the LAG Switch is closed.
57
SOCKETS & ACCESSORIES
Sockets
Product Number
70169-D *
Product Number
70170-D
Product Number
70171-D
Description
8 Pin Octal
11 Pin Octal
11 Pin Spade (Blade)
Ratings
10A @ 600V *
10A @ 300V
10A @ 300V
Mounting
35MM DIN Rail /
Direct Panel
35MM DIN Rail /
Direct Panel
35MM DIN Rail /
Direct Panel
Wire/
Terminations
1 or 2 #12-22 /
Pressure Wire Clamps
1 or 2 #12-22 /
Pressure Wire Clamps
1 or 2 #12-22 /
Pressure Wire Clamps
Approvals
Dimensions
All Dimensions in
Inches (Millimeters)
*
Plug-in Three-Phase Monitor Relays require a 600V-rated socket when used on system voltages greater than 300V.
Other Accessories
Hold Down Spring
Product Number 70166
DIN Mounting Track (3 FT. Section)
Product Number 70100
End Clamp
Product Number 70200
58
A
t Macromatic, we are committed
to providing you with the right
product, at the right time and at
the right price.
Alternating Relays
STANDARD PRODUCTS
!
!
!
!
!
Time Delay Relays
Alternating Relays
Phase Monitoring Relays
Voltage Monitoring Relays
Current Monitor Relays
C USTOM DESIGNS
!
!
Time Delay Relays
!
Save money with a dedicated design to fit
your application
Proprietary design protection offered
Agency approvals available
TECHNICAL S UPPORT
!
Dedicated engineering team
One-on-one assistance
Application selection help
Technical troubleshooting aid
!
Toll free help line
!
!
!
C USTOMER S ERVICE
!
Phase Monitor Relays
!
!
!
!
Total Quality Program responsive to your
needs
Short lead times on small quantity orders
Never a charge for expedited delivery
Local support through distributors & sales
representatives
No minimum orders on standard products
Voltage Monitor Relays
For Details Contact us at
800-238-7474 ! 262-781-3366
FAX 262-781-4433
www.macromatic.com
whats-up@macromatic.com
Current Monitor Relays
The Right Product
The Right Time
The Right Price
Macromatic Controls
W134 N5345 Campbell Dr
Menomonee Falls, WI 53051
800-238-7474- ! 262-781-3366 ! Fax 262-781-4433
Web: www.macromatic.com ! Email: whats-up@macromatic.com