Bridgelux Gen 8 Vero 18 Array
®
®
Product Data Sheet DS422
1
Vero® Series
Introduction
The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying
the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES
configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero
arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Features
Benefits
• On board connector port
• Solder free installation and field upgradability
• Top side part number markings
• Improved inventory management and quality control
• Efficacy of 180 lm/W typical, 3000K 80 CRI
• Enables high efficiency lighting systems and lower
operating costs
• Reliable operation at up to 3x nominal current, 30%
increase in maximum lumens per LES size
• Wide selection of CCT options (2700K-6500K) with
minimum 70, 80 and 90 CRI options
• Uniform high-quality illumination
• 2 and 3 SDCM binning options (2700K – 4000K)
• Forward voltage bin codes (backside marking)
• Thermally isolated solder pads
• 10-Year warranty
• Supports the trend toward luminaire miniaturization
and delivers enhanced optical control
• Design flexibility for a broad range of lighting
applications
• Clean white light without pixelation
• Uniform consistent white light
• Design flexibility for multi-source applications
• Enhanced ease of use and installation
• Design with confidence
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
7
Electrical Characteristics
16
Eye Safety
17
Absolute Maximum Ratings
18
Performance Curves
19
Typical Radiation Pattern
21
Typical Color Spectrum
22
Mechanical Dimensions
23
Color Binning Information
24
Packaging and Labeling
25
Design Resources
27
Precautions
27
Disclaimers
27
About Bridgelux
28
1
Product Feature Map
Vero 18 is the second largest form factor in the Vero
family of next generation solid state light sources. In
addition to delivering the performance and light quality
required for many lighting applications, Vero incorporates
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
2D Bar code provides full manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
Optics location/mounting features
Mounting holes
Radial die configuration improves lumen
density and beam control
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRC – 30 E 400 0 – C – 8 3
CCT Bin Options
Product Family
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen. 8
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
400x = 4000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E4000-B-8x
2700
80
700
4028
3625
33.9
23.7
170
BXRC-27E4000-C-8x
2700
80
1050
6024
5421
33.9
35.6
169
BXRC-27E4000-D-8x
2700
80
850
4055
3649
28.2
24.0
169
BXRC-27G4000-B-8x
2700
90
700
3323
2991
33.9
23.7
140
BXRC-27G4000-C-8x
2700
90
1050
4969
4472
33.9
35.6
140
BXRC-27G4000-D-8x
2700
90
850
3345
3011
28.2
24.0
140
BXRC-27G40H0-B-8x
2700
90
700
3467
3120
33.9
23.7
146
BXRC-27G40H0-C-8x
2700
90
1050
5184
4666
33.9
35.6
146
BXRC-27G40H0-D-8x
2700
90
850
3489
3141
28.2
24.0
146
BXRC-30C4001-B-8x
3000
70
700
4481
4033
33.9
23.7
189
188
BXRC-30C4001-C-8x
3000
70
1050
6701
6031
33.9
35.6
BXRC-30C4001-D-8x
3000
70
850
4511
4060
28.2
24.0
188
BXRC-30E4000-B-8x
3000
80
700
4280
3852
33.9
23.7
180
BXRC-30E4000-C-8x
3000
80
1050
6400
5760
33.9
35.6
180
BXRC-30E4000-D-8x
3000
80
850
4308
3877
28.2
24.0
180
BXRC-30G4000-B-8x
3000
90
700
3474
3127
33.9
23.7
146
BXRC-30G4000-C-8x
3000
90
1050
5195
4676
33.9
35.6
146
BXRC-30G4000-D-8x
3000
90
850
3497
3147
28.2
24.0
146
BXRC-30G40H0-B-8x
3000
90
700
3638
3274
33.9
23.7
153
BXRC-30G40H0-C-8x
3000
90
1050
5440
4896
33.9
35.6
153
BXRC-30G40H0-D-8x
3000
90
850
3662
3296
28.2
24.0
153
BXRC-35E4000-B-8x
3500
80
700
4381
3943
33.9
23.7
185
BXRC-35E4000-C-8x
3500
80
1050
6551
5896
33.9
35.6
184
BXRC-35E4000-D-8x
3500
80
850
4409
3968
28.2
24.0
184
BXRC-35G4000-B-8x
3500
90
700
3600
3240
33.9
23.7
152
BXRC-35G4000-C-8x
3500
90
1050
5384
4845
33.9
35.6
151
BXRC-35G4000-D-8x
3500
90
850
3624
3261
28.2
24.0
151
BXRC-40C4001-B-8x
4000
70
700
4607
4147
33.9
23.7
194
194
BXRC-40C4001-C-8x
4000
70
1050
6889
6200
33.9
35.6
BXRC-40C4001-D-8x
4000
70
850
4637
4174
28.2
24.0
193
BXRC-40E4000-B-8x
4000
80
700
4406
3965
33.9
23.7
186
BXRC-40E4000-C-8x
4000
80
1050
6588
5929
33.9
35.6
185
BXRC-40E4000-D-8x
4000
80
850
4435
3991
28.2
24.0
185
BXRC-40G4000-B-8x
4000
90
700
3676
3308
33.9
23.7
155
BXRC-40G4000-C-8x
4000
90
1050
5496
4947
33.9
35.6
154
BXRC-40G4000-D-8x
4000
90
850
3700
3330
28.2
24.0
154
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a
± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50C4001-B-8x
5000
70
700
4632
4169
33.9
23.7
195
BXRC-50C4001-C-8x
5000
70
1050
6927
6234
33.9
35.6
195
BXRC-50C4001-D-8x
5000
70
850
4663
4196
28.2
24.0
195
BXRC-50E4001-B-8x
5000
80
700
4456
4011
33.9
23.7
188
BXRC-50E4001-C-8x
5000
80
1050
6664
5997
33.9
35.6
187
BXRC-50E4001-D-8x
5000
80
850
4485
4037
28.2
24.0
187
BXRC-50G4001-B-8x
5000
90
700
3852
3467
33.9
23.7
162
BXRC-50G4001-C-8x
5000
90
1050
5760
5184
33.9
35.6
162
BXRC-50G4001-D-8x
5000
90
850
3877
3489
28.2
24.0
162
BXRC-57C4001-B-8x
5700
70
700
4507
4056
33.9
23.7
190
189
BXRC-57C4001-C-8x
5700
70
1050
6739
6065
33.9
35.6
BXRC-57C4001-D-8x
5700
70
850
4536
4082
28.2
24.0
189
BXRC-57E4001-B-8x
5700
80
700
4280
3852
33.9
23.7
180
BXRC-57E4001-C-8x
5700
80
1050
6400
5760
33.9
35.6
180
BXRC-57E4001-D-8x
5700
80
850
4308
3877
28.2
24.0
180
BXRC-65C4001-B-8x
6500
70
700
4507
4056
33.9
23.7
190
BXRC-65C4001-C-8x
6500
70
1050
6739
6065
33.9
35.6
189
BXRC-65C4001-D-8x
6500
70
850
4536
4082
28.2
24.0
189
BXRC-65E4001-B-8x
6500
80
700
4330
3897
33.9
23.7
182
BXRC-65E4001-C-8x
6500
80
1050
6475
5828
33.9
35.6
182
BXRC-65E4001-D-8x
6500
80
850
4359
3923
28.2
24.0
182
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux
maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
4
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E4000-B-8x
2700
80
700
3625
3263
33.1
23.2
156
BXRC-27E4000-C-8x
2700
80
1050
5421
4879
33.1
34.8
156
BXRC-27E4000-D-8x
2700
80
850
3649
3284
27.7
23.5
155
BXRC-27G4000-B-8x
2700
90
700
2991
2692
33.1
23.2
129
BXRC-27G4000-C-8x
2700
90
1050
4472
4025
33.1
34.8
129
BXRC-27G4000-D-8x
2700
90
850
3011
2709
27.7
23.5
128
BXRC-27G40H0-B-8x
2700
90
700
3120
2808
33.1
23.2
135
BXRC-27G40H0-C-8x
2700
90
1050
4666
4199
33.1
34.8
134
BXRC-27G40H0-D-8x
2700
90
850
3141
2826
27.7
23.5
134
BXRC-30C4001-B-8x
3000
70
700
4033
3630
33.1
23.2
174
BXRC-30C4001-C-8x
3000
70
1050
6031
5428
33.1
34.8
173
BXRC-30C4001-D-8x
3000
70
850
4060
3654
27.7
23.5
173
BXRC-30E4000-B-8x
3000
80
700
3852
3467
33.1
23.2
166
BXRC-30E4000-C-8x
3000
80
1050
5760
5184
33.1
34.8
166
BXRC-30E4000-D-8x
3000
80
850
3877
3489
27.7
23.5
165
BXRC-30G4000-B-8x
3000
90
700
3127
2814
33.1
23.2
135
BXRC-30G4000-C-8x
3000
90
1050
4676
4208
33.1
34.8
134
BXRC-30G4000-D-8x
3000
90
850
3147
2833
27.7
23.5
134
BXRC-30G40H0-B-8x
3000
90
700
3274
2947
33.1
23.2
141
BXRC-30G40H0-C-8x
3000
90
1050
4896
4406
33.1
34.8
141
BXRC-30G40H0-D-8x
3000
90
850
3296
2966
27.7
23.5
140
BXRC-35E4000-B-8x
3500
80
700
3943
3548
33.1
23.2
170
BXRC-35E4000-C-8x
3500
80
1050
5896
5306
33.1
34.8
170
BXRC-35E4000-D-8x
3500
80
850
3968
3572
27.7
23.5
169
BXRC-35G4000-B-8x
3500
90
700
3240
2916
33.1
23.2
140
BXRC-35G4000-C-8x
3500
90
1050
4845
4361
33.1
34.8
139
BXRC-35G4000-D-8x
3500
90
850
3261
2935
27.7
23.5
139
BXRC-40C4001-B-8x
4000
70
700
4147
3732
33.1
23.2
179
BXRC-40C4001-C-8x
4000
70
1050
6200
5580
33.1
34.8
178
BXRC-40C4001-D-8x
4000
70
850
4174
3756
27.7
23.5
178
BXRC-40E4000-B-8x
4000
80
700
3965
3569
33.1
23.2
171
BXRC-40E4000-C-8x
4000
80
1050
5929
5336
33.1
34.8
171
BXRC-40E4000-D-8x
4000
80
850
3991
3592
27.7
23.5
170
BXRC-40G4000-B-8x
4000
90
700
3308
2977
33.1
23.2
143
BXRC-40G4000-C-8x
4000
90
1050
4947
4452
33.1
34.8
142
BXRC-40G4000-D-8x
4000
90
850
3330
2997
27.7
23.5
142
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
180
BXRC-50C4001-B-8x
5000
70
700
4169
3752
33.1
23.2
BXRC-50C4001-C-8x
5000
70
1050
6234
5611
33.1
34.8
179
BXRC-50C4001-D-8x
5000
70
850
4196
3777
27.7
23.5
178
BXRC-50E4001-B-8x
5000
80
700
4011
3610
33.1
23.2
173
BXRC-50E4001-C-8x
5000
80
1050
5997
5397
33.1
34.8
172
BXRC-50E4001-D-8x
5000
80
850
4037
3633
27.7
23.5
172
BXRC-50G4001-B-8x
5000
90
700
3467
3120
33.1
23.2
150
BXRC-50G4001-C-8x
5000
90
1050
5184
4666
33.1
34.8
149
BXRC-50G4001-D-8x
5000
90
850
3489
3141
27.7
23.5
148
BXRC-57C4001-B-8x
5700
70
700
4056
3650
33.1
23.2
175
BXRC-57C4001-C-8x
5700
70
1050
6065
5458
33.1
34.8
174
BXRC-57C4001-D-8x
5700
70
850
4082
3674
27.7
23.5
174
BXRC-57E4001-B-8x
5700
80
700
3852
3467
33.1
23.2
166
BXRC-57E4001-C-8x
5700
80
1050
5760
5184
33.1
34.8
166
BXRC-57E4001-D-8x
5700
80
850
3877
3489
27.7
23.5
165
BXRC-65C4001-B-8x
6500
70
700
4056
3650
33.1
23.2
175
BXRC-65C4001-C-8x
6500
70
1050
6065
5458
33.1
34.8
174
BXRC-65C4001-D-8x
6500
70
850
4082
3674
27.7
23.5
174
BXRC-65E4001-B-8x
6500
80
700
3897
3508
33.1
23.2
168
BXRC-65E4001-C-8x
6500
80
1050
5828
5245
33.1
34.8
168
BXRC-65E4001-D-8x
6500
80
850
3923
3531
27.7
23.5
167
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3.
Table 3: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-27E4000-B-8x
80
BXRC-27E4000-C-8x
80
BXRC-27E4000-D-8x
80
BXRC-27G4000-B-8x
90
BXRC-27G4000-C-8x
90
BXRC-27G4000-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
2115
3065
4028
5053
7600
10500
3162
4570
6024
6616
11365
15700
2128
3141
4055
4901
7650
10845
1745
2529
3323
4169
6270
8662
2609
3770
4969
5458
9376
12953
1756
2591
3345
4043
6311
8947
1903
2759
3625
4548
6840
9450
2846
4113
5421
5954
10228
14130
1916
2827
3649
4411
6885
9761
1570
2276
2991
3752
5643
7796
2348
3393
4472
4912
8438
11658
1580
2332
3011
3639
5680
8053
185
175
170
163
151
140
184
175
169
166
150
139
184
174
169
163
150
138
153
145
140
134
125
115
152
144
140
137
124
115
152
144
140
135
124
114
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
7
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27G40H0-B-8x
90
BXRC-27G40H0-C-8x
90
BXRC-27G40H0-D-8x
90
BXRC-30C4001-B-8x
70
BXRC-30C4001-C-8x
70
BXRC-30C4001-D-8x
70
BXRC-30E4000-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
1820
2638
3467
4349
6541
9036
2721
3933
5184
5694
9781
13512
1832
2703
3489
4218
6584
9334
2353
3410
4481
5622
8455
11681
3518
5084
6701
7360
12643
17467
2368
3495
4511
5452
8511
12065
2247
3257
4280
5369
8075
11156
1638
2374
3120
3914
5887
8133
2449
3540
4666
5125
8803
12161
1649
2433
3141
3796
5925
8400
2117
3069
4033
5060
7610
10513
3166
4576
6031
6624
11379
15720
2131
3145
4060
4907
7660
10859
2022
2931
3852
4832
7268
10040
159
151
146
140
130
120
159
151
146
143
129
120
159
150
146
140
129
119
206
195
189
181
168
156
205
195
188
184
167
155
205
194
188
182
167
154
196
186
181
173
160
149
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30E4000-C-8x
80
BXRC-30E4000-D-8x
80
BXRC-30G4000-B-8x
90
BXRC-30G4000-C-8x
90
BXRC-30G4000-D-8x
90
BXRC-30G40H0-B-8x
90
BXRC-30G40H0-C-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
3360
4856
6400
7030
12075
16682
2262
3338
4308
5207
8128
11523
1824
2644
3474
4359
6555
9056
2727
3942
5195
5706
9802
13542
1836
2709
3497
4227
6598
9354
1910
2768
3638
4564
6864
9482
2856
4127
5440
5975
10264
14179
3024
4370
5760
6327
10868
15013
2035
3004
3877
4687
7315
10371
1641
2379
3127
3923
5900
8150
2455
3548
4676
5136
8822
12187
1652
2438
3147
3804
5938
8419
1719
2492
3274
4108
6178
8534
2570
3715
4896
5378
9238
12761
196
186
180
176
160
148
196
185
180
173
160
147
159
151
147
140
130
121
159
151
146
143
130
120
159
150
146
141
130
119
167
158
153
147
136
126
166
158
153
150
136
126
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
9
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G40H0-D-8x
90
BXRC-35E4000-B-8x
80
BXRC-35E4000-C-8x
80
BXRC-35E4000-D-8x
80
BXRC-35G4000-B-8x
90
BXRC-35G4000-C-8x
90
BXRC-35G4000-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
1922
2837
3662
4426
6909
9795
2300
3334
4381
5496
8265
11418
3439
4970
6551
7195
12359
17074
2315
3416
4409
5330
8319
11794
1890
2740
3600
4517
6793
9384
2826
4085
5384
5913
10157
14032
1902
2807
3624
4380
6837
9693
1730
2553
3296
3984
6218
8815
2070
3000
3943
4946
7439
10276
3095
4473
5896
6476
11123
15367
2083
3074
3968
4797
7487
10615
1701
2466
3240
4065
6113
8446
2544
3676
4845
5322
9142
12629
1712
2527
3261
3942
6153
8724
166
158
153
147
136
125
201
191
185
177
164
152
200
190
184
180
164
152
200
190
184
178
164
151
165
157
152
145
135
125
165
156
151
148
134
125
165
156
151
146
134
124
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C4001-B-8x
70
BXRC-40C4001-C-8x
70
BXRC-40C4001-D-8x
70
BXRC-40E4000-B-8x
80
BXRC-40E4000-C-8x
80
BXRC-40E4000-D-8x
80
BXRC-40G4000-B-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
2419
3506
4607
5780
8693
12009
3617
5227
6889
7567
12999
17957
2434
3593
4637
5606
8750
12404
2313
3353
4406
5527
8313
11484
3459
4999
6588
7236
12430
17172
2328
3436
4435
5360
8367
11862
1930
2797
3676
4611
6935
9581
2177
3155
4147
5202
7824
10808
3255
4704
6200
6810
11699
16162
2191
3233
4174
5045
7875
11164
2082
3017
3965
4974
7482
10336
3113
4499
5929
6513
11187
15455
2095
3092
3991
4824
7530
10676
1737
2517
3308
4150
6242
8623
211
201
194
186
173
160
211
200
194
190
172
159
211
199
194
187
172
158
202
192
186
178
165
153
202
191
185
181
165
152
202
191
185
179
165
151
169
160
155
149
138
128
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40G4000-C-8x
90
BXRC-40G4000-D-8x
90
BXRC-50C4001-B-8x
70
BXRC-50C4001-C-8x
70
BXRC-50C4001-D-8x
70
BXRC-50E4001-B-8x
80
BXRC-50E4001-C-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
2885
4170
5496
6037
10370
14327
1942
2866
3700
4472
6981
9896
2432
3525
4632
5811
8740
12075
3636
5256
6927
7609
13070
18055
2448
3612
4663
5636
8798
12472
2339
3391
4456
5590
8408
11615
3498
5056
6664
7319
12572
17369
2597
3753
4947
5433
9333
12894
1748
2580
3330
4025
6283
8907
2189
3173
4169
5230
7866
10867
3273
4730
6234
6848
11763
16250
2203
3251
4196
5073
7918
11225
2105
3052
4011
5031
7567
10454
3148
4550
5997
6587
11315
15632
168
160
155
151
137
127
168
159
155
149
137
126
213
202
195
187
174
161
212
201
195
191
173
160
212
201
195
188
173
159
205
194
188
180
167
155
204
194
187
183
166
154
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50E4001-D-8x
80
BXRC-50G4001-B-8x
90
BXRC-50G4001-C-8x
90
BXRC-50G4001-D-8x
90
BXRC-57C4001-B-8x
70
BXRC-57C4001-C-8x
70
BXRC-57C4001-D-8x
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
2355
3475
4485
5422
8463
11997
2022
2931
3852
4832
7268
10040
3024
4370
5760
6327
10868
15013
2035
3004
3877
4687
7315
10371
2366
3429
4507
5654
8503
11746
3538
5113
6739
7402
12714
17565
2381
3514
4536
5483
8558
12133
2119
3127
4037
4880
7617
10798
1820
2638
3467
4349
6541
9036
2721
3933
5184
5694
9781
13512
1832
2703
3489
4218
6584
9334
2129
3086
4056
5088
7653
10572
3184
4602
6065
6662
11443
15808
2143
3163
4082
4935
7703
10920
204
193
187
181
166
153
177
168
163
156
144
134
176
167
162
159
144
133
176
167
162
156
144
132
207
196
190
182
169
156
206
196
190
185
168
156
206
195
190
183
168
155
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57E4001-B-8x
80
BXRC-57E4001-C-8x
80
BXRC-57E4001-D-8x
80
BXRC-65C4001-B-8x
70
BXRC-65C4001-C-8x
70
BXRC-65C4001-D-8x
70
BXRC-65E4001-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
350
525
700
900
1400
2000
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
32.7
33.3
33.9
34.5
36.0
37.5
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
11.4
17.5
23.7
31.0
50.4
75.1
2247
3257
4280
5369
8075
11156
3360
4856
6400
7030
12075
16682
2262
3338
4308
5207
8128
11523
2366
3429
4507
5654
8503
11746
3538
5113
6739
7402
12714
17565
2381
3514
4536
5483
8558
12133
2273
3295
4330
5432
8170
11287
2022
2931
3852
4832
7268
10040
3024
4370
5760
6327
10868
15013
2035
3004
3877
4687
7315
10371
2129
3086
4056
5088
7653
10572
3184
4602
6065
6662
11443
15808
2143
3163
4082
4935
7703
10920
2046
2966
3897
4889
7353
10158
196
186
181
173
160
149
196
186
180
176
160
148
196
185
180
173
160
147
207
196
190
182
169
156
206
196
190
185
168
156
206
195
190
183
168
155
199
189
183
175
162
150
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-65E4001-C-8x
80
BXRC-65E4001-D-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
525
785
1050
1170
2100
3000
425
650
850
1050
1700
2500
32.7
33.3
33.9
34.1
36.0
37.5
27.2
27.7
28.2
28.6
29.9
31.3
17.2
26.1
35.6
39.9
75.5
112.6
11.6
18.0
23.9
30.0
50.9
78.3
3399
4913
6475
7112
12217
16878
2288
3377
4359
5269
8224
11659
3059
4422
5828
6401
10996
15190
2059
3039
3923
4742
7401
10493
198
188
182
178
162
150
198
187
182
175
162
149
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Electrical Characteristics
Table 4: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx400x-B-8x
BXRC-xxx400x-C-8x
BXRC-xxx400x-D-8x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.14
30.5
37.2
-12.10
0.23
33.7
41.1
36.4
-10.93
0.12
30.5
37.2
37.5
40.3
-12.10
0.20
33.7
41.1
26.1
28.2
30.3
-9.10
0.13
25.4
30.9
29.0
31.3
33.6
-10.10
0.22
28.1
34.3
Minimum
Typical
Maximum
700
31.4
33.9
36.4
-10.93
2000
34.7
37.5
40.3
1050
31.4
33.9
3000
34.7
850
2500
Notes for Table 4:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working
voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
16
Eye Safety
Table 5: Eye Safety Risk Group (RG) Classifications
Part Number
CCT
Drive Current
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1440
RG1
RG1
RG1
RG1
2000
RG1
RG1
RG1
RG2
1440
RG1
RG1
RG1
RG1
1995
RG1
RG1
RG1
RG2
2650
RG1
RG1
RG2
RG2
3000
RG1
RG2
RG2
RG2
1730
RG1
RG1
RG1
RG1
2400
RG1
RG1
RG1
RG2
2500
RG1
RG1
RG2
RG2
BXRC-xxx400x-B-8x
BXRC-xxx400x-C-8x
BXRC-xxx400x-D-8x
Notes for Table 5:
1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1980 lx.
3. For products classified as RG2 at 5000K Ethr= 1530 lx.
4. For products classified as RG2 at 6500K, Ethr= 1170 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
17
Absolute Maximum Ratings
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx400x-B-8x
BXRC-xxx400x-C-8x
BXRC-xxx400x-D-8x
Maximum Drive Current3
2000 mA
3000 mA
2500 mA
Maximum Peak Pulsed Drive Current4
2240 mA
3360 mA
2800 mA
Maximum Reverse Voltage5
-60V
-60V
-50V
Notes for Table 6:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
18
Performance Curves
Figure 1: Vero 18B Drive Current vs. Voltage
Figure 2: Vero 18C Drive Current vs. Voltage
38.0
38.0
37.0
36.0
Voltage (V)
Voltage (V)
37.0
35.0
34.0
36.0
35.0
34.0
33.0
33.0
32.0
32.0
0
250
500
750
1000
1250
1500
1750
2000
0
2250
500
1000
Drive Current (mA)
2000
2500
3000
3500
Figure 4: Vero 18B Typical Relative Flux vs. Current
Figure 3: Vero 18D Drive Current vs. Voltage
32.0
300%
Relative Luminous Flux (%)
31.5
31.0
30.5
Voltage (V)
1500
Drive Current (mA)
30.0
29.5
29.0
28.5
28.0
27.5
250%
200%
150%
100%
50%
27.0
0%
26.5
0
500
1000
1500
2000
2500
0
3000
250
Figure 5: Vero 18C Typical Relative Flux vs. Current
750
1000
1250
1500
1750
2000
2250
Figure 6 Vero 18D Typical Relative Flux vs. Current
300%
Relative Luminous Flux (%)
300%
Relative Luminous Flux (%)
500
Drive Current (mA)
Drive Current (mA)
250%
200%
150%
100%
50%
250%
200%
150%
100%
50%
0%
0%
0
500
1000
1500
2000
Drive Current (mA)
2500
3000
3500
0
500
1000
1500
2000
2500
3000
Drive Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
19
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
102%
0.0010
100%
0.0000
-0.0010
98%
-0.0020
96%
ccy shift
Relative Luminous Flux
Figure 7: Typical DC Flux vs. Case Temperature
94%
92%
-0.0030
-0.0040
-0.0050
90%
-0.0060
88%
-0.0070
0
20
40
60
80
100
120
0
20
Case Temperature (Tc)
60
80
100
120
Case Temperature (Tc)
Figure 10: Derating Curve
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.0020
3500
25C Pulsed
0.0000
40
Drive Current (mA)
3000
ccx shift
-0.0020
-0.0040
-0.0060
-0.0080
2500
2000
1500
1000
BXRC-xxx400x-C-8x
500
0
-0.0100
0
20
40
60
80
Case Temperature (Tc)
100
120
0
20
40
60
80
Case Temperature (Tc)
100
120
20
Typical Radiation Pattern
Figure 11: Typical Spatial Radiation Pattern
Note for Figure 11:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 12: Typical Polar Radiation Pattern
21
Typical Color Spectrum
Figure 13: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 13:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
22
Mechanical Dimensions
Figure 14: Drawing for Vero 18 LED Array
Notes for Figure 14:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
23
Color Binning Information
Figure 15: Warm and Neutral White Test Bins in xy Color Space
0.44
3 SDCM
2 SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
0.38
0.36
0.34
0.36
0.39
0.42
X
0.45
0.48
Note: Pulsed Test Conditions, Tc = 25°C
Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
2700K
3000K
3500K
4000K
ANSI Bin
(for reference only)
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
83 (3 SDCM)
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
82 (2 SDCM)
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Figure 16: Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5312K - 6022K)
(6022K - 7042K)
84 (4 SDCM)
(4801K - 5282K)
(5481K - 5829K)
(6270K - 6765K)
83 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3287, 0.3417)
(0.3123, 0.3282)
24
Packaging and Labeling
Figure 17: Drawing for Vero 18 Packaging Tray
Notes for Figure 17:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
25
Packaging and Labeling
Figure 18: Vero Series Packaging and Labeling
Notes for Figure 18:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 19: Gen. 8 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E4000C 83 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
26
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
27
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series
HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 8 Vero 18 Array Series Product Data Sheet DS422 Rev. A (07/2020)
28