Bridgelux Vero SE 29 Array
®
®
Product Data Sheet DS123
1
Vero SE
Introduction
Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with
poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower
manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility.
Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current
range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays
into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam
control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting.
Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor
Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Features
• Poke-in connectivity
• Efficacy of 170 lm/W typical
• Lumen output performance ranges from 5,368 to
37,173 lumens
Benefits
• Poke-in connectivity enables solderless, connector
free installation
• Broad application coverage for interior and exterior
lighting
• Broad range of CCT options from 1750K to 6500K
• Flexibility for application driven lighting design
requirements
• CRI options: minimum 65, 70, 80, and 90
• High quality, true color reproduction
• Color control: 2 and 3 SDCM for 2700K-4000K CCT
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Top side part number markings
• No exposed solder pads or electrical connections
• Ability to configure multiple arrays in series and
parallel reduces customer driver cost
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
20
Eye Safety
21
Absolute Maximum Ratings
22
Performance Curves
23
Typical Radiation Pattern
27
Typical Color Spectrum
28
Mechanical Dimensions
29
Color Binning Information
30
Packaging and Labeling
31
Design Resources
33
Precautions
33
Disclaimers
33
About Bridgelux
34
1
Product Feature Map
Vero SE 29 is the largest form factor in the product family
of next generation solid state light sources. In addition to
delivering the performance and light quality required for
many lighting applications, Vero SE incorporates several
features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero SE Series family of products.
2D Bar code provides full
manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Wire release mechanisms x4
Tc Measurement point
Optic mounting holes
Radial die configuration improves lumen
density and beam control
Mounting holes
Top side part number marking improves
inventory management and outgoing
quality control
Test ports for probing
Dual poke-in connectivity
Product Nomenclature
The part number designation for Bridgelux Vero SE LED arrays is explained as follows:
1 2 3 4
–
5 6 7 8 9 10 11
– 12
– 13 14
– 15 16
BXRC – 30 E 10K 0 – C – 7 3 – SE
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Special Edition
CCT Bin Options
Gen. 7
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
A = Class A
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
Flux Indicator
10Kx = 10,000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal
Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74-SE
1750
80
1800
8590
7731
52.0
93.6
92
BXRC-17E10K0-C-74-SE
1750
80
1710
10891
9802
69.4
118.7
92
BXRC-17E10K0-D-74-SE
1750
80
2100
7246
6522
37.6
79.0
92
BXRC-20B10K1-C-73-SE
2000
65
1710
18585
16727
69.4
118.7
157
BXRC-20B10K1-D-73-SE
2000
65
2100
12366
11129
37.6
79.0
157
BXRC-25E10K0-B-74-SE
2500
80
1800
14285
12856
52.0
93.6
153
BXRC-25E10K0-C-74-SE
2500
80
1710
18112
16301
69.4
118.7
153
BXRC-25E10K0-D-74-SE
2500
80
2100
12051
10846
37.6
79.0
153
BXRC-27E10K0-B-7x-SE
2700
80
1800
14939
13445
52.0
93.6
160
BXRC-27E10K0-C-7x-SE
2700
80
1710
18940
17046
69.4
118.7
160
BXRC-27E10K0-D-7x-SE
2700
80
2100
12602
11342
37.6
79.0
160
BXRC-27G1KH0-B-7x-SE
2700
90
1800
12791
11512
52.0
93.6
137
BXRC-27G1KH0-C-7x-SE
2700
90
1710
16218
14596
69.4
118.7
137
BXRC-27G1KH0-D-7x-SE
2700
90
2100
10790
9711
37.6
79.0
137
BXRC-27G10K0-B-7x-SE
2700
90
1800
12324
11092
52.0
93.6
132
BXRC-27G10K0-C-7x-SE
2700
90
1710
15626
14063
69.4
118.7
132
BXRC-27G10K0-D-7x-SE
2700
90
2100
10397
9357
37.6
79.0
132
BXRC-27H10K0-D-74-SE
2700
97
2100
9215
8294
37.6
79.0
117
BXRC-30C10K1-B-74-SE
3000
70
1800
16619
14957
52.0
93.6
178
178
BXRC-30C10K1-C-74-SE
3000
70
1710
21071
18964
69.4
118.7
BXRC-30C10K1-D-74-SE
3000
70
2100
14020
12618
37.6
79.0
178
BXRC-30E10K0-B-7x-SE10
3000
80
1800
15872
14285
52.0
93.6
170
BXRC-30E10K0-C-7x-SE10
3000
80
1710
20124
18112
69.4
118.7
170
BXRC-30E10K0-D-7x-SE10
3000
80
2100
13390
12051
37.6
79.0
170
BXRC-30G1KH0-B-7x-SE
3000
90
1800
13445
12100
52.0
93.6
144
BXRC-30G1KH0-C-7x-SE
3000
90
1710
17046
15342
69.4
118.7
144
BXRC-30G1KH0-D-7x-SE
3000
90
2100
11342
10208
37.6
79.0
144
BXRC-30G10K0-B-7x-SE
3000
90
1800
12885
11596
52.0
93.6
138
BXRC-30G10K0-C-7x-SE
3000
90
1710
16336
14702
69.4
118.7
138
BXRC-30G10K0-D-7x-SE
3000
90
2100
10869
9782
37.6
79.0
138
BXRC-30H10K0-D-7X-SE
3000
97
2100
9845
8861
37.6
79.0
125
8,9
BXRC-30A10K1-B-73-SE
3000
93
1800
11577
10420
52.0
93.6
124
BXRC-30A10K1-C-73-SE8,9
3000
93
1710
14679
13211
69.4
118.7
124
BXRC-30A10K1-D-73-SE8,9
3000
93
2100
9767
8790
37.6
79.0
124
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI
Nominal
Drive
Current3
(mA)
2
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7x-SE10
3500
80
1800
16246
14621
52.0
93.6
174
BXRC-35E10K0-C-7x-SE10
3500
80
1710
20598
18538
69.4
118.7
174
BXRC-35E10K0-D-7x-SE
3500
80
2100
13705
12334
37.6
79.0
174
BXRC-35G10K0-B-7x-SE
3500
90
1800
13351
12016
52.0
93.6
143
10
BXRC-35G10K0-C-7x-SE
3500
90
1710
16928
15235
69.4
118.7
143
BXRC-35G10K0-D-7x-SE
3500
90
2100
11263
10137
37.6
79.0
143
BXRC-35A10K1-B-73-SE8,9
3500
93
1800
12324
11092
52.0
93.6
132
BXRC-35A10K1-C-73-SE8,9
3500
93
1710
15626
14063
69.4
118.7
132
BXRC-35A10K1-D-73-SE8,9
3500
93
2100
10397
9357
37.6
79.0
132
BXRC-40C10K1-B-74-SE
4000
70
1800
17086
15377
52.0
93.6
183
BXRC-40C10K1-C-74-SE
4000
70
1710
21663
19497
69.4
118.7
183
BXRC-40C10K1-D-74-SE
4000
70
2100
14414
12972
37.6
79.0
183
BXRC-40E10K0-B-7x-SE10
4000
80
1800
16339
14705
52.0
93.6
175
BXRC-40E10K0-C-7x-SE10
4000
80
1710
20716
18644
69.4
118.7
175
BXRC-40E10K0-D-7x-SE
4000
80
2100
13783
12405
37.6
79.0
175
BXRC-40G10K0-B-7x-SE
4000
90
1800
13631
12268
52.0
93.6
146
10
BXRC-40G10K0-C-7x-SE
4000
90
1710
17283
15555
69.4
118.7
146
BXRC-40G10K0-D-7x-SE
4000
90
2100
11499
10349
37.6
79.0
146
BXRC-40H10K0-D-7X-SE
4000
97
2100
10397
9357
37.6
79.0
132
BXRC-40A10K1-B-73-SE8,9
4000
93
1800
13351
12016
52.0
93.6
143
BXRC-40A10K1-C-73-SE8,9
4000
93
1710
16928
15235
69.4
118.7
143
8,9
BXRC-40A10K1-D-73-SE
4000
93
2100
11263
10137
37.6
79.0
143
BXRC-50C10K1-B-7x-SE10
5000
70
1800
17179
15461
52.0
93.6
184
BXRC-50C10K1-C-7x-SE10
5000
70
1710
21781
19603
69.4
118.7
184
BXRC-50C10K1-D-7x-SE10
5000
70
2100
14492
13043
37.6
79.0
184
BXRC-50E10K1-B-7x-SE10
5000
80
1800
16526
14873
52.0
93.6
177
BXRC-50E10K1-C-7x-SE10
5000
80
1710
20953
18858
69.4
118.7
177
BXRC-50E10K1-D-7x-SE10
5000
80
2100
13941
12547
37.6
79.0
177
BXRC-50G10K1-B-7x-SE
5000
90
1800
14285
12856
52.0
93.6
153
BXRC-50G10K1-C-74-SE
5000
90
1710
18112
16301
69.4
118.7
153
BXRC-50G10K1-D-74-SE
5000
90
2100
12051
10846
37.6
79.0
153
BXRC-56G10K0-B-74-SE
5600
80
1800
14378
12941
52.0
93.6
154
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Nominal
Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
80
1710
18230
16407
69.4
118.7
154
80
2100
12129
10916
37.6
79.0
154
5600
97
2100
10948
9853
37.6
79.0
139
Part Number
Nominal
CCT1
(K)
CRI2
BXRC-56G10K0-C-74-SE
5600
BXRC-56G10Kx-D-74-SE
5600
BXRC-56H10K0-D-74-SE
BXRC-57C10K1-B-74-SE
5700
70
1800
16713
15041
52.0
93.6
179
BXRC-57C10K1-C-74-SE
5700
70
1710
21190
19071
69.4
118.7
179
BXRC-57C10K1-D-74-SE
5700
70
2100
14099
12689
37.6
79.0
179
BXRC-57E10K1-B-74-SE
5700
80
1800
15872
14285
52.0
93.6
170
BXRC-57E10K1-C-74-SE
5700
80
1710
20124
18112
69.4
118.7
170
BXRC-57E10K1-D-74-SE
5700
80
2100
13390
12051
37.6
79.0
170
BXRC-65C10K1-B-74-SE
6500
70
1800
16713
15041
52.0
93.6
179
BXRC-65C10K1-C-74-SE
6500
70
1710
21190
19071
69.4
118.7
179
BXRC-65C10K1-D-74-SE
6500
70
2100
14099
12689
37.6
79.0
179
BXRC-65E10K1-B-74-SE
6500
80
1800
16059
14453
52.0
93.6
172
BXRC-65E10K1-C-74-SE
6500
80
1710
20361
18325
69.4
118.7
172
BXRC-65E10K1-D-74-SE
6500
80
2100
13547
12192
37.6
79.0
172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A10K1-B-73-SE
3000
80
93
1800
10767
9690
50.9
91.6
118
BXRC-30A10K1-C-73-SE
3000
80
93
1710
13651
12286
67.9
116.1
118
BXRC-30A10K1-D-73-SE
3000
80
93
2100
9083
8175
36.8
77.3
118
BXRC-35A10K1-B-73-SE
3500
80
93
1800
11462
10315
50.9
91.6
125
BXRC-35A10K1-C-73-SE
3500
80
93
1710
14532
13079
67.9
116.1
125
BXRC-35A10K1-D-73-SE
3500
80
93
2100
9669
8702
36.8
77.3
125
BXRC-40A10K1-B-73-SE
4000
80
93
1800
12417
11175
50.9
91.6
136
BXRC-40A10K1-C-73-SE
4000
80
93
1710
15743
14169
67.9
116.1
136
BXRC-40A10K1-D-73-SE
4000
80
93
2100
10475
9427
36.8
77.3
136
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Nominal
CCT1 (K)
Part Number
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
85
BXRC-17E10K0-B-74-SE
1750
80
1800
7731
6958
50.7
91.2
BXRC-17E10K0-C-74-SE
1750
80
1710
9802
8821
68.1
116.4
84
BXRC-17E10K0-D-74-SE
1750
80
2100
6522
5869
36.6
76.8
85
BXRC-20B10K1-C-73-SE
2000
65
1710
16727
15054
68.1
116.4
144
BXRC-20B10K1-D-73-SE
2000
65
2100
11129
10016
36.6
76.8
145
BXRC-25E10K0-B-74-SE
2500
80
1800
12856
11571
50.7
91.2
141
BXRC-25E10K0-C-74-SE
2500
80
1710
16301
14671
68.1
116.4
140
BXRC-25E10K0-D-74-SE
2500
80
2100
10846
9761
36.6
76.8
141
BXRC-27E10K0-B-7x-SE
2700
80
1800
13445
12100
50.7
91.2
147
BXRC-27E10K0-C-7x-SE
2700
80
1710
17046
15342
68.1
116.4
146
BXRC-27E10K0-D-7x-SE
2700
80
2100
11342
10208
36.6
76.8
148
BXRC-27G1KH0-B-7x-SE
2700
90
1800
11512
10361
50.7
91.2
126
BXRC-27G1KH0-C-7x-SE
2700
90
1710
14596
13136
68.1
116.4
125
BXRC-27G1KH0-D-7x-SE
2700
90
2100
9711
8740
36.6
76.8
127
BXRC-27G10K0-B-7x-SE
2700
90
1800
11092
9983
50.7
91.2
122
BXRC-27G10K0-C-7x-SE
2700
90
1710
14063
12657
68.1
116.4
121
BXRC-27G10K0-D-7x-SE
2700
90
2100
9357
8421
36.6
76.8
122
BXRC-27H10K0-D-74-SE
2700
97
2100
8294
7464
36.6
76.9
108
164
BXRC-30C10K1-B-74-SE
3000
70
1800
14957
13462
50.7
91.2
BXRC-30C10K1-C-74-SE
3000
70
1710
18964
17068
68.1
116.4
163
BXRC-30C10K1-D-74-SE
3000
70
2100
12618
11356
36.6
76.8
164
BXRC-30E10K0-B-7x-SE
3000
80
1800
14285
12856
50.7
91.2
157
BXRC-30E10K0-C-7x-SE
3000
80
1710
18112
16301
68.1
116.4
156
BXRC-30E10K0-D-7x-SE
3000
80
2100
12051
10846
36.6
76.8
157
BXRC-30G1KH0-B-7X-SE
3000
90
1800
12100
10890
50.7
91.2
133
BXRC-30G1KH0-C-7X-SE
3000
90
1710
15342
13808
68.1
116.4
132
BXRC-30G1KH0-D-7X-SE
3000
90
2100
10208
9187
36.6
76.8
133
BXRC-30G10K0-B-7x-SE
3000
90
1800
11596
10436
50.7
91.2
127
BXRC-30G10K0-C-7x-SE
3000
90
1710
14702
13232
68.1
116.4
126
BXRC-30G10K0-D-7x-SE
3000
90
2100
9782
8804
36.6
76.8
127
BXRC-30H10K0-D-7X-SE
3000
97
2100
8861
7975
36.6
76.8
115
7,8
BXRC-30A10K1-B-73-SE
3000
93
1800
10420
9378
50.7
91.2
114
BXRC-30A10K1-C-73-SE7,8
3000
93
1710
13211
11890
68.1
116.4
113
BXRC-30A10K1-D-73-SE7,8
3000
93
2100
8790
7911
36.6
76.8
114
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7x-SE
3500
80
1800
14621
13159
50.7
91.2
160
BXRC-35E10K0-C-7x-SE
3500
80
1710
18538
16684
68.1
116.4
159
BXRC-35E10K0-D-7x-SE
3500
80
2100
12334
11101
36.6
76.8
161
132
BXRC-35G10K0-B-7x-SE
3500
90
1800
12016
10815
50.7
91.2
BXRC-35G10K0-C-7x-SE
3500
90
1710
15235
13712
68.1
116.4
131
BXRC-35G10K0-D-7x-SE
3500
90
2100
10137
9123
36.6
76.8
132
BXRC-35A10K1-B-73-SE7,8
3500
93
1800
11092
9983
50.7
91.2
122
BXRC-35A10K1-C-73-SE7,8
3500
93
1710
14063
12657
68.1
116.4
121
BXRC-35A10K1-D-73-SE7,8
3500
93
2100
9357
8421
36.6
76.8
122
BXRC-40C10K1-B-74-SE
4000
70
1800
15377
13840
50.7
91.2
169
BXRC-40C10K1-C-74-SE
4000
70
1710
19497
17547
68.1
116.4
167
BXRC-40C10K1-D-74-SE
4000
70
2100
12972
11675
36.6
76.8
169
BXRC-40E10K0-B-7x-SE
4000
80
1800
14705
13235
50.7
91.2
161
BXRC-40E10K0-C-7x-SE
4000
80
1710
18644
16780
68.1
116.4
160
BXRC-40E10K0-D-7x-SE
4000
80
2100
12405
11165
36.6
76.8
162
BXRC-40G10K0-B-7x-SE
4000
90
1800
12268
11041
50.7
91.2
135
BXRC-40G10K0-C-7x-SE
4000
90
1710
15555
13999
68.1
116.4
134
BXRC-40G10K0-D-7x-SE
4000
90
2100
10349
9314
36.6
76.8
135
BXRC-40H10K0-D-7X-SE
4000
97
2100
9357
8421
36.6
76.8
122
7,8
BXRC-40A10K1-B-73-SE
4000
93
1800
12016
10815
50.7
91.2
132
BXRC-40A10K1-C-73-SE7,8
4000
93
1710
15235
13712
68.1
116.4
131
BXRC-40A10K1-D-73-SE7,8
4000
93
2100
10137
9123
36.6
76.8
132
BXRC-50C10K1-B-7x-SE
5000
70
1800
15461
13915
50.7
91.2
170
BXRC-50C10K1-C-7x-SE
5000
70
1710
19603
17643
68.1
116.4
168
BXRC-50C10K1-D-7x-SE
5000
70
2100
13043
11739
36.6
76.8
170
163
BXRC-50E10K1-B-7x-SE
5000
80
1800
14873
13386
50.7
91.2
BXRC-50E10K1-C-7x-SE
5000
80
1710
18858
16972
68.1
116.4
162
BXRC-50E10K1-D-7x-SE
5000
80
2100
12547
11292
36.6
76.8
163
BXRC-50G10K1-B-7x-SE
5000
90
1800
12856
11571
50.7
91.2
141
BXRC-50G10K1-C-7x-SE
5000
90
1710
16301
14671
68.1
116.4
140
BXRC-50G10K1-D-7x-SE
5000
90
2100
10846
9761
36.6
76.8
141
BXRC-56G10K1-B-74-SE
5600
80
1800
12941
11646
50.7
91.2
142
BXRC-56G10K1-C-74-SE
5600
80
1710
16407
14766
68.1
116.4
141
BXRC-56G10Kx-D-74-SE
5600
80
2100
10916
9825
36.6
76.8
142
BXRC-56H10K0-D-74-SE
5600
97
2100
9853
8868
36.6
76.8
128
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal
CCT1 (K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
165
BXRC-57C10K1-B-7x-SE
5700
70
1800
15041
13537
50.7
91.2
BXRC-57C10K1-C-7x-SE
5700
70
1710
19071
17164
68.1
116.4
164
BXRC-57C10K1-D-7x-SE
5700
70
2100
12689
11420
36.6
76.8
165
BXRC-57E10K1-B-7x-SE
5700
80
1800
14285
12856
50.7
91.2
157
BXRC-57E10K1-C-7x-SE
5700
80
1710
18112
16301
68.1
116.4
156
BXRC-57E10K1-D-7x-SE
5700
80
2100
12051
10846
36.6
76.8
157
BXRC-65C10K1-B-7x-SE
6500
70
1800
15041
13537
50.7
91.2
165
BXRC-65C10K1-C-7x-SE
6500
70
1710
19071
17164
68.1
116.4
164
BXRC-65C10K1-D-7x-SE
6500
70
2100
12689
11420
36.6
76.8
165
BXRC-65E10K1-B-7x-SE
6500
80
1800
14453
13008
50.7
91.2
158
BXRC-65E10K1-C-7x-SE
6500
80
1710
18325
16492
68.1
116.4
157
BXRC-65E10K1-D-7x-SE
6500
80
2100
12192
10973
36.6
76.8
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E10K0-B-74-SE
80
BXRC-17E10K0-C-74-SE
80
BXRC-17E10K0-D-74-SE
80
BXRC-20B10K1-C-73-SE
65
BXRC-20B10K1-D-73-SE
65
BXRC-25E10K0-B-74-SE
80
BXRC-25E10K0-C-74-SE
80
BXRC-25E10K0-D-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
4459
5871
8590
12382
15847
6187
7863
10891
15450
19365
3986
5130
7246
10316
13002
10558
13419
18585
26365
33047
6802
8754
12366
17604
22188
7416
9764
14285
20592
26355
10289
13077
18112
25694
32205
6628
8531
12051
17156
21623
4070
5337
7731
11042
13963
5887
7253
9802
13288
16272
3884
4774
6522
8692
10617
10047
12378
16727
22676
27768
6627
8147
11129
14833
18118
6769
8876
12856
18364
23221
9791
12063
16301
22099
27061
6459
7939
10846
14455
17657
100
97
92
85
79
109
103
92
84
76
107
101
92
83
75
187
175
157
143
130
183
173
157
142
128
166
161
153
141
131
182
170
153
139
127
178
168
153
138
125
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E10K0-B-7x-SE
80
BXRC-27E10K0-C-7x-SE
80
BXRC-27E10K0-D-7x-SE
80
BXRC-27G1KH0-B-7x-SE
90
BXRC-27G1KH0-C-7x-SE
90
BXRC-27G1KH0-D-7x-SE
90
BXRC-27G10K0-B-7x-SE
90
BXRC-27G10K0-C-7x-SE
90
BXRC-27G10K0-D-7x-SE
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
7755
10211
14939
21534
27561
10759
13675
18940
26869
33678
6932
8921
12602
17941
22612
6640
8743
12791
18438
23599
9213
11709
16218
23007
28837
5935
7639
10790
15362
19361
6398
8424
12324
17765
22738
8877
11282
15626
22167
27784
5719
7360
10397
14801
18655
7079
9282
13445
19204
24283
10239
12615
17046
23110
28299
6754
8302
11342
15117
18464
6061
7948
11512
16444
20792
8767
10801
14596
19788
24231
5783
7109
9711
12944
15810
5840
7658
11092
15843
20033
8447
10407
14063
19065
23347
5572
6849
9357
12471
15233
174
169
160
147
137
190
178
160
145
132
186
176
160
144
131
149
144
137
126
117
163
153
137
124
113
160
151
137
124
112
143
139
132
122
113
157
147
132
120
109
154
145
132
119
108
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27H10K0-D-74-SE
97
BXRC-30C10K1-B-74-SE
70
BXRC-30C10K1-C-74-SE
70
BXRC-30C10K1-D-74-SE
70
BXRC-30E10K0-B-7x-SE
80
BXRC-30E10K0-C-7x-SE
80
BXRC-30E10K0-D-7x-SE
80
BXRC-30G1KH0-B-7x-SE
90
BXRC-30G1KH0-C-7x-SE
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
5069
6523
9215
13119
16535
9441
11999
16619
23576
29551
11590
14916
21071
29998
37808
7712
9925
14020
19959
25156
8240
10849
15872
22879
29283
11432
14530
20124
28549
35783
7365
9479
13390
19062
24025
6979
9190
13445
19380
24805
9683
12308
17046
24182
30310
4939
6071
8294
11054
13502
8984
11069
14957
20277
24831
11293
13882
18964
25276
30873
7514
9236
12618
16817
20542
7521
9862
14285
20404
25801
10878
13403
18112
24554
30068
7176
8821
12051
16062
19619
6371
8354
12100
17284
21855
9215
11353
15342
20799
25469
136
129
117
105
96
211
198
178
161
147
205
194
178
162
149
207
196
178
160
145
184
179
170
157
146
202
189
170
154
141
198
187
170
153
139
156
152
144
133
123
171
160
144
131
119
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G1KH0-D-7x-SE
90
BXRC-30G10K0-B-7x-SE
90
BXRC-30G10K0-C-7x-SE
90
BXRC-30G10K0-D-7x-SE
90
BXRC-30H10K0-D-7x-SE
97
BXRC-30A10K1-B-73-SE
93
BXRC-30A10K1-C-73-SE
93
BXRC-30A10K1-D-73-SE
93
BXRC-35E10K0-B-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
6239
8029
11342
16147
20351
6689
8807
12885
18573
23771
9280
11795
16336
23175
29047
5979
7694
10869
15474
19503
5415
6970
9845
14016
17665
6010
7914
11577
16689
21360
8339
10598
14679
20824
26100
5372
6914
9767
13904
17524
8434
11105
16246
23418
29972
6079
7472
10208
13605
16618
6106
8006
11596
16564
20944
8831
10880
14702
19932
24408
5825
7161
9782
13038
15926
5277
6486
8861
11810
14425
5486
7193
10420
14883
18819
7935
9776
13211
17910
21932
5234
6434
8790
11715
14310
7698
10094
14621
20884
26408
168
159
144
130
118
150
145
138
127
118
164
154
138
125
114
161
152
138
124
113
146
138
125
113
102
135
131
124
114
106
147
138
124
113
103
144
137
124
112
101
189
183
174
160
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35E10K0-C-7x-SE
80
BXRC-35E10K0-D-7x-SE
80
BXRC-35G10K0-B-7x-SE
90
BXRC-35G10K0-C-7x-SE
90
BXRC-35G10K0-D-7x-SE
90
BXRC-35A10K1-B-73-SE
93
BXRC-35A10K1-C-73-SE
93
BXRC-35A10K1-D-73-SE
93
BXRC-40C10K1-B-74-SE
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
11701
14872
20598
29220
36625
7538
9702
13705
19511
24590
6931
9126
13351
19246
24632
9616
12222
16928
24014
30100
6195
7973
11263
16035
20209
6398
8424
12324
17765
22738
8877
11282
15626
22167
27784
5719
7360
10397
14801
18655
8870
11679
17086
24629
31523
11134
13718
18538
25132
30775
7345
9029
12334
16439
20080
6327
8296
12016
17164
21703
9151
11274
15235
20654
25292
6036
7420
10137
13511
16503
5840
7658
11092
15843
20033
8447
10407
14063
19065
23347
5572
6849
9357
12471
15233
8096
10616
15377
21965
27774
207
194
174
158
144
203
192
174
157
142
155
151
143
132
123
170
159
143
130
118
166
157
143
129
117
143
139
132
122
113
157
147
132
120
109
154
145
132
119
108
199
193
183
169
157
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C10K1-C-74-SE
70
BXRC-40C10K1-D-74-SE
70
BXRC-40E10K0-B-7x-SE
80
BXRC-40E10K0-C-7x-SE
80
BXRC-40E10K0-D-7x-SE
80
BXRC-40G10K0-B-7x-SE
90
BXRC-40G10K0-C-7x-SE
90
BXRC-40G10K0-D-7x-SE
90
BXRC-40H10K0-D-7x-SE
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
12306
15641
21663
30732
38519
7928
10203
14414
20520
25862
8482
11168
16339
23552
30145
11768
14957
20716
29388
36835
7582
9757
13783
19623
24732
7076
9318
13631
19649
25149
9818
12479
17283
24518
30731
6325
8140
11499
16371
20633
5719
7360
10397
14801
18655
11710
14428
19497
26432
32367
7725
9496
12972
17290
21119
7743
10152
14705
21004
26560
11198
13797
18644
25276
30952
7387
9081
12405
16534
20196
6459
8470
12268
17524
22158
9343
11511
15555
21087
25823
6163
7576
10349
13794
16849
5572
6849
9357
12471
15233
217
204
183
166
151
213
201
183
165
150
190
184
175
161
150
208
195
175
159
145
204
193
175
158
143
158
154
146
135
125
174
163
146
133
121
170
161
146
132
119
154
145
132
119
108
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A10K1-B-73-SE
93
BXRC-40A10K1-C-73-SE
93
BXRC-40A10K1-D-73-SE
93
BXRC-50C10K1-B-74-SE
70
BXRC-50C10K1-C-74-SE
70
BXRC-50C10K1-D-74-SE
70
BXRC-50E10K1-B-74-SE
80
BXRC-50E10K1-C-74-SE
80
BXRC-50E10K1-D-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
6931
9126
13351
19246
24632
9616
12222
16928
24014
30100
6195
7973
11263
16035
20209
8918
11743
17179
24764
31695
12373
15726
21781
30900
38730
7971
10259
14492
20632
26004
8579
11296
16526
23822
30489
11903
15128
20953
29724
37256
7668
9869
13941
19847
25014
6327
8296
12016
17164
21703
9151
11274
15235
20654
25292
6036
7420
10137
13511
16503
8141
10674
15461
22085
27925
11774
14507
19603
26576
32544
7767
9548
13043
17384
21234
7831
10268
14873
21245
26863
11326
13955
18858
25565
31306
7472
9184
12547
16723
20426
155
151
143
132
123
170
159
143
130
118
166
157
143
129
117
200
194
184
170
158
219
205
184
167
152
214
203
184
166
150
192
187
177
163
152
210
197
177
161
146
206
195
177
160
145
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G10K1-B-74-SE
90
BXRC-50G10K1-C-74-SE
90
BXRC-50G10K1-D-74-SE
90
BXRC-56G10K0-B-74-SE
80
BXRC-56G10K0-C-74-SE
80
BXRC-56G10K0-D-74-SE
80
BXRC-56H10K0-D-74-SE
80
BXRC-57C10K1-B-74-SE
70
BXRC-57C10K1-C-74-SE
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7416
9764
14285
20592
26355
10289
13077
18112
25694
32205
6628
8531
12051
17156
21623
7464
9828
14378
20726
26527
10356
13162
18230
25862
32415
6672
8586
12129
17268
21764
6022
7750
10948
15586
19644
8676
11424
16713
24091
30834
12037
15299
21190
30060
37677
6769
8876
12856
18364
23221
9791
12063
16301
22099
27061
6459
7939
10846
14455
17657
6813
8934
12941
18484
23372
9855
12141
16407
22243
27238
6501
7991
10916
14550
17772
5868
7213
9853
13133
16041
7920
10384
15041
21485
27167
11454
14112
19071
25854
31659
166
161
153
141
131
182
170
153
139
127
178
168
153
138
125
167
162
154
142
132
183
172
154
140
127
179
170
154
139
126
162
153
139
125
114
194
189
179
165
153
213
199
179
162
148
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57C10K1-D-74-SE
70
BXRC-57E10K1-B-74-SE
80
BXRC-57E10K1-C-74-SE
80
BXRC-57E10K1-D-74-SE
80
BXRC-65C10K1-B-74-SE
70
BXRC-65C10K1-C-74-SE
70
BXRC-65C10K1-D-74-SE
70
BXRC-65E10K1-B-74-SE
80
BXRC-65E10K1-C-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7755
9980
14099
20071
25297
8240
10849
15872
22879
29283
11432
14530
20124
28549
35783
7365
9479
13390
19062
24025
8676
11424
16713
24091
30834
12037
15299
21190
30060
37677
7755
9980
14099
20071
25297
8337
10977
16059
23149
29628
11566
14701
20361
28884
36204
7556
9288
12689
16912
20657
7521
9862
14285
20404
25801
10878
13403
18112
24554
30068
7176
8821
12051
16062
19619
7920
10384
15041
21485
27167
11454
14112
19071
25854
31659
7556
9288
12689
16912
20657
7610
9978
14453
20644
26104
11006
13561
18325
24843
30421
208
197
179
161
146
184
179
170
157
146
202
189
170
154
141
198
187
170
153
139
194
189
179
165
153
213
199
179
162
148
208
197
179
161
146
187
181
172
158
147
204
192
172
156
142
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
BXRC-65E10K1-D-7x-SE
CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
80
1050
1400
2100
3150
4200
35.4
36.2
37.6
39.5
41.2
37.2
50.6
79.0
124.4
172.9
7452
9590
13547
19286
24308
7261
8925
12192
16251
19849
200
189
172
155
141
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
19
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.06
46.1
57.5
-24.9
0.07
49.7
61.6
74.6
-33.2
0.04
61.5
76.8
74.4
80.0
-33.2
0.05
66.2
82.2
34.8
37.6
40.4
-17.4
0.06
33.4
41.6
38.1
41.2
44.3
-17.4
0.07
36.7
45.4
Minimum
Typical
Maximum
1800
48.1
52.0
55.9
-24.9
3600
51.7
55.8
60.0
1710
64.2
69.4
3420
68.8
2100
4200
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal
interface material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design
and selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
20
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1800
RG1
RG1
RG1
RG1
2700
RG1
RG1
RG2
RG2
3600
RG1
RG1
RG2
RG2
1710
RG1
RG1
RG1
RG2
2565
RG1
RG1
RG2
RG2
3420
RG1
RG2
RG2
RG2
2100
RG1
RG1
RG1
RG1
3150
RG1
RG1
RG1
RG2
4200
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC
62471 for the assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
21
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
BXRC-xxx10Kx-B-7x-SE
BXRC-xxx10Kx-C-7x-SE
BXRC-xxx10Kx-D-7x-SE
Maximum Drive Current3
3600mA
3420mA
4200mA
Maximum Peak Pulsed Drive Current4
5140mA
4890mA
6000mA
Maximum Reverse Voltage5
-90V
-120V
-65V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
22
Performance Curves
Figure 2: Vero SE 29C Drive Current vs. Voltage
4000
4000
3500
3500
3000
3000
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero SE 29B Drive Current vs. Voltage
2500
2000
1500
1000
2500
2000
1500
1000
500
0
500
47
48
49
50
51
52
53
54
55
56
57
0
58
63
64
65
66
67
68
Forward Voltage (V)
Figure 3: Vero SE 29D Drive Current vs. Voltage
71
72
73
74
75
76
200%
180%
4000
160%
Relative Luminous Flux
3500
Forward Current (mA)
70
Figure 4: Vero SE 29B Typical Relative Flux vs. Current
4500
3000
2500
2000
1500
1000
140%
120%
100%
80%
60%
40%
500
0
69
Forward Voltage (V)
20%
33
34
35
36
37
38
39
40
41
42
0%
0
Forward Voltage (V)
500
1000
1500
2000
2500
3000
3500
4000
Forward Current (mA)
Figure 6 Vero SE 29D Typical Relative Flux vs. Current
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
Figure 5: Vero SE 29C Typical Relative Flux vs. Current
120%
100%
80%
60%
120%
100%
80%
60%
40%
40%
20%
20%
0%
0
400
800
1200
1600
2000
2400
Forward Current (mA)
2800
3200
3600
4000
0%
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
23
Performance Curves
Figure 7: Typical DC Flux vs. Case Temperature
Figure 8: Typical DC ccy Shift vs. Case Temperature
0
103%
Neutral White
50
75
100
125
0.000
Cool White
25°C Pulsed
97%
-0.003
ccy Shift
Relative Luminous Flux
100%
25
0.003
Warm White
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
-0.015
82%
0
25
50
75
100
Neutral White
Cool White
25°C Pulsed
125
Case Temperature (°C)
Case Temperature (°C)
Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.4101
0
25
50
75
100
0.41
125
0.4099
0.000
0.4098
-0.002
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
ccy
ccx Shift
-0.004
-0.006
65°C
0.4093
Warm White
-0.012
0.4095
0.4094
-0.008
-0.010
45°C
0.4096
Neutral White
85°C
0.4092
Cool White
25°C Pulsed
105°C
0.4091
Case Temperature (°C)
0.409
0.525
0.526
0.527
0.528
0.529
0.53
0.531
0.532
ccx
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. . For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
24
Performance Curves
Figure 11: 1750K Color Shift vs. Case Temperature1
Figure 12: 2500K Color Shift vs. Case Temperature1
0.3705
0.4145
Pulsed Center Point
Tc = 25°C
15°C
0.37
15°C
0.414
25°C
0.413
0.3695
0.369
ccy
ccy
45°C
85°C
0.411
105°C
0.52
70°C
85°C
0.4115
0.3685
0.5198
45°C
0.4125
0.412
70°C
0.368
0.5196
0.5202
0.5204
105°C
0.4105
0.468
0.5206
0.47
0.472
Figure 13: 5600K Color Shift vs. Case Temperature1,3
0.369
0.342
25°C
0.338
25°C
0.367
0.366
0.336
45°C
0.334
ccy
ccy
15°C
0.368
Pulsed Center
Point
Tc = 25°C
15°C
0.34
0.332
70°C
0.478
Pulsed
Center Point
Tc=25°C
45°C
0.365
0.364
70°C
0.363
85°C
0.328
0.476
Figure 14: 3000K Class A Color Shift vs. Case Temperature1
0.344
0.326
0.474
ccx
ccx
0.33
Pulsed
Center Point
Tc = 25°C
0.4135
25°C
85°C
0.362
105°C
0.361
0.324
0.322
0.32
0.322
0.324
0.326
0.328
105°C
0.36
0.416
0.33
0.4165
0.417
ccx
Figure 15: 3500K Class A Color Shift vs. Case Temperature1
ccx
0.4175
0.418
0.4185
Figure 16: 4000K Class A Color Shift vs. Case Temperature1
0.37
0.3760
15°C
0.368
Pulsed
Center Point
Tc=25°C
25°C
0.366
15°C
0.3740
25°C
0.3720
45°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.364
0.3680
70°C
0.362
85°C
0.36
85°C
0.3640
105°C
0.358
0.392
70°C
0.3660
105°C
0.393
0.394
0.395
0.396
0.397
ccx
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
Note for Figures 10-16:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
25
Performance Curves
Figure 17: Vero SE 29D Drive Current Derating Curve
4400
Drive Current (mA)
4200
4000
3960
3800
3600
3400
Max Drive Current
LM-80 Max Drive Current
3200
0
10
20
30
40
50
60
70
80
90
100
110
Case Temperature (⁰C)
Notes for Figure 17:
1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product
Feature Map (page 2) for the location of the Tc Point
2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections.
3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included
in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report.
26
Typical Radiation Pattern
Figure 18: Typical Spatial Radiation Pattern
Note for Figure 18:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 19: Typical Polar Radiation Pattern
27
Typical Color Spectrum
Figure 20: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 20:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 21: Typical Color Spectrum for Vero SE 29 with Décor Series
1
17E
20B
0.9
25E
27H
Relative Spectral Power Distribution
0.8
30H
56G
0.7
56H
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 21:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
28
Mechanical Dimensions
Figure 22: Drawing for Vero SE 29 LED Array
Notes for Figure 22:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ± 0.10mm.
4. Mounting holes (2X) are for M3 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
29
Color Binning Information
Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space
0.44
2500K
4SDCM
3 SDCM
4 SDCM
2000K
3SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
1750K
4SDCM
0.38
0.36
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2500K
2700K
3000K1
3500K1
4000K1
ANSI Bin
(for reference only)
-
-
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
-
-
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
-
-
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.5167, 0.336)
(0.4765, 0.4137)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Class A products. Please contact your Bridgelux Sales Representative for more information.
Figure 24: Graph of Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K1
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
30
Packaging and Labeling
Figure 25: Drawing for Vero SE 29 Packaging Tray
Notes for Figure 25:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
31
Packaging and Labeling
Figure 26: Vero SE Series Packaging and Labeling
Notes for Figure 26:
1. Each tray holds 50 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 27: Vero SE Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E10K0C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin
definitions.
32
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN120 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
33
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD
are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Vero SE 29 Array Series Product Data Sheet DS123 Rev. L (03/2019)
34