0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-35E4000-D-83

BXRC-35E4000-D-83

  • 厂商:

    BRIDGELUX

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
BXRC-35E4000-D-83 数据手册
Bridgelux Gen 8 Vero 18 Array ® ® Product Data Sheet DS422 1 Vero® Series Introduction The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Features Benefits • On board connector port • Solder free installation and field upgradability • Top side part number markings • Improved inventory management and quality control • Efficacy of 180 lm/W typical, 3000K 80 CRI • Enables high efficiency lighting systems and lower operating costs • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options • Uniform high-quality illumination • 2 and 3 SDCM binning options (2700K – 4000K) • Forward voltage bin codes (backside marking) • Thermally isolated solder pads • 10-Year warranty • Supports the trend toward luminaire miniaturization and delivers enhanced optical control • Design flexibility for a broad range of lighting applications • Clean white light without pixelation • Uniform consistent white light • Design flexibility for multi-source applications • Enhanced ease of use and installation • Design with confidence Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 7 Electrical Characteristics 16 Eye Safety 17 Absolute Maximum Ratings 18 Performance Curves 19 Typical Radiation Pattern 21 Typical Color Spectrum 22 Mechanical Dimensions 23 Color Binning Information 24 Packaging and Labeling 25 Design Resources 27 Precautions 27 Disclaimers 27 About Bridgelux 28 1 Product Feature Map Vero 18 is the second largest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. Thermally isolated solder pads reduce manufacturing cycle time and complexity 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Optics location/mounting features Mounting holes Radial die configuration improves lumen density and beam control Zhaga Book 3 compatible mounting locations Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 400 0 – C – 8 3 CCT Bin Options Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 8 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 400x = 4000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E4000-B-8x 2700 80 700 4028 3625 33.9 23.7 170 BXRC-27E4000-C-8x 2700 80 1050 6024 5421 33.9 35.6 169 BXRC-27E4000-D-8x 2700 80 850 4055 3649 28.2 24.0 169 BXRC-27G4000-B-8x 2700 90 700 3323 2991 33.9 23.7 140 BXRC-27G4000-C-8x 2700 90 1050 4969 4472 33.9 35.6 140 BXRC-27G4000-D-8x 2700 90 850 3345 3011 28.2 24.0 140 BXRC-27G40H0-B-8x 2700 90 700 3467 3120 33.9 23.7 146 BXRC-27G40H0-C-8x 2700 90 1050 5184 4666 33.9 35.6 146 BXRC-27G40H0-D-8x 2700 90 850 3489 3141 28.2 24.0 146 BXRC-30C4001-B-8x 3000 70 700 4481 4033 33.9 23.7 189 188 BXRC-30C4001-C-8x 3000 70 1050 6701 6031 33.9 35.6 BXRC-30C4001-D-8x 3000 70 850 4511 4060 28.2 24.0 188 BXRC-30E4000-B-8x 3000 80 700 4280 3852 33.9 23.7 180 BXRC-30E4000-C-8x 3000 80 1050 6400 5760 33.9 35.6 180 BXRC-30E4000-D-8x 3000 80 850 4308 3877 28.2 24.0 180 BXRC-30G4000-B-8x 3000 90 700 3474 3127 33.9 23.7 146 BXRC-30G4000-C-8x 3000 90 1050 5195 4676 33.9 35.6 146 BXRC-30G4000-D-8x 3000 90 850 3497 3147 28.2 24.0 146 BXRC-30G40H0-B-8x 3000 90 700 3638 3274 33.9 23.7 153 BXRC-30G40H0-C-8x 3000 90 1050 5440 4896 33.9 35.6 153 BXRC-30G40H0-D-8x 3000 90 850 3662 3296 28.2 24.0 153 BXRC-35E4000-B-8x 3500 80 700 4381 3943 33.9 23.7 185 BXRC-35E4000-C-8x 3500 80 1050 6551 5896 33.9 35.6 184 BXRC-35E4000-D-8x 3500 80 850 4409 3968 28.2 24.0 184 BXRC-35G4000-B-8x 3500 90 700 3600 3240 33.9 23.7 152 BXRC-35G4000-C-8x 3500 90 1050 5384 4845 33.9 35.6 151 BXRC-35G4000-D-8x 3500 90 850 3624 3261 28.2 24.0 151 BXRC-40C4001-B-8x 4000 70 700 4607 4147 33.9 23.7 194 194 BXRC-40C4001-C-8x 4000 70 1050 6889 6200 33.9 35.6 BXRC-40C4001-D-8x 4000 70 850 4637 4174 28.2 24.0 193 BXRC-40E4000-B-8x 4000 80 700 4406 3965 33.9 23.7 186 BXRC-40E4000-C-8x 4000 80 1050 6588 5929 33.9 35.6 185 BXRC-40E4000-D-8x 4000 80 850 4435 3991 28.2 24.0 185 BXRC-40G4000-B-8x 4000 90 700 3676 3308 33.9 23.7 155 BXRC-40G4000-C-8x 4000 90 1050 5496 4947 33.9 35.6 154 BXRC-40G4000-D-8x 4000 90 850 3700 3330 28.2 24.0 154 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50C4001-B-8x 5000 70 700 4632 4169 33.9 23.7 195 BXRC-50C4001-C-8x 5000 70 1050 6927 6234 33.9 35.6 195 BXRC-50C4001-D-8x 5000 70 850 4663 4196 28.2 24.0 195 BXRC-50E4001-B-8x 5000 80 700 4456 4011 33.9 23.7 188 BXRC-50E4001-C-8x 5000 80 1050 6664 5997 33.9 35.6 187 BXRC-50E4001-D-8x 5000 80 850 4485 4037 28.2 24.0 187 BXRC-50G4001-B-8x 5000 90 700 3852 3467 33.9 23.7 162 BXRC-50G4001-C-8x 5000 90 1050 5760 5184 33.9 35.6 162 BXRC-50G4001-D-8x 5000 90 850 3877 3489 28.2 24.0 162 BXRC-57C4001-B-8x 5700 70 700 4507 4056 33.9 23.7 190 189 BXRC-57C4001-C-8x 5700 70 1050 6739 6065 33.9 35.6 BXRC-57C4001-D-8x 5700 70 850 4536 4082 28.2 24.0 189 BXRC-57E4001-B-8x 5700 80 700 4280 3852 33.9 23.7 180 BXRC-57E4001-C-8x 5700 80 1050 6400 5760 33.9 35.6 180 BXRC-57E4001-D-8x 5700 80 850 4308 3877 28.2 24.0 180 BXRC-65C4001-B-8x 6500 70 700 4507 4056 33.9 23.7 190 BXRC-65C4001-C-8x 6500 70 1050 6739 6065 33.9 35.6 189 BXRC-65C4001-D-8x 6500 70 850 4536 4082 28.2 24.0 189 BXRC-65E4001-B-8x 6500 80 700 4330 3897 33.9 23.7 182 BXRC-65E4001-C-8x 6500 80 1050 6475 5828 33.9 35.6 182 BXRC-65E4001-D-8x 6500 80 850 4359 3923 28.2 24.0 182 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 4 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E4000-B-8x 2700 80 700 3625 3263 33.1 23.2 156 BXRC-27E4000-C-8x 2700 80 1050 5421 4879 33.1 34.8 156 BXRC-27E4000-D-8x 2700 80 850 3649 3284 27.7 23.5 155 BXRC-27G4000-B-8x 2700 90 700 2991 2692 33.1 23.2 129 BXRC-27G4000-C-8x 2700 90 1050 4472 4025 33.1 34.8 129 BXRC-27G4000-D-8x 2700 90 850 3011 2709 27.7 23.5 128 BXRC-27G40H0-B-8x 2700 90 700 3120 2808 33.1 23.2 135 BXRC-27G40H0-C-8x 2700 90 1050 4666 4199 33.1 34.8 134 BXRC-27G40H0-D-8x 2700 90 850 3141 2826 27.7 23.5 134 BXRC-30C4001-B-8x 3000 70 700 4033 3630 33.1 23.2 174 BXRC-30C4001-C-8x 3000 70 1050 6031 5428 33.1 34.8 173 BXRC-30C4001-D-8x 3000 70 850 4060 3654 27.7 23.5 173 BXRC-30E4000-B-8x 3000 80 700 3852 3467 33.1 23.2 166 BXRC-30E4000-C-8x 3000 80 1050 5760 5184 33.1 34.8 166 BXRC-30E4000-D-8x 3000 80 850 3877 3489 27.7 23.5 165 BXRC-30G4000-B-8x 3000 90 700 3127 2814 33.1 23.2 135 BXRC-30G4000-C-8x 3000 90 1050 4676 4208 33.1 34.8 134 BXRC-30G4000-D-8x 3000 90 850 3147 2833 27.7 23.5 134 BXRC-30G40H0-B-8x 3000 90 700 3274 2947 33.1 23.2 141 BXRC-30G40H0-C-8x 3000 90 1050 4896 4406 33.1 34.8 141 BXRC-30G40H0-D-8x 3000 90 850 3296 2966 27.7 23.5 140 BXRC-35E4000-B-8x 3500 80 700 3943 3548 33.1 23.2 170 BXRC-35E4000-C-8x 3500 80 1050 5896 5306 33.1 34.8 170 BXRC-35E4000-D-8x 3500 80 850 3968 3572 27.7 23.5 169 BXRC-35G4000-B-8x 3500 90 700 3240 2916 33.1 23.2 140 BXRC-35G4000-C-8x 3500 90 1050 4845 4361 33.1 34.8 139 BXRC-35G4000-D-8x 3500 90 850 3261 2935 27.7 23.5 139 BXRC-40C4001-B-8x 4000 70 700 4147 3732 33.1 23.2 179 BXRC-40C4001-C-8x 4000 70 1050 6200 5580 33.1 34.8 178 BXRC-40C4001-D-8x 4000 70 850 4174 3756 27.7 23.5 178 BXRC-40E4000-B-8x 4000 80 700 3965 3569 33.1 23.2 171 BXRC-40E4000-C-8x 4000 80 1050 5929 5336 33.1 34.8 171 BXRC-40E4000-D-8x 4000 80 850 3991 3592 27.7 23.5 170 BXRC-40G4000-B-8x 4000 90 700 3308 2977 33.1 23.2 143 BXRC-40G4000-C-8x 4000 90 1050 4947 4452 33.1 34.8 142 BXRC-40G4000-D-8x 4000 90 850 3330 2997 27.7 23.5 142 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 180 BXRC-50C4001-B-8x 5000 70 700 4169 3752 33.1 23.2 BXRC-50C4001-C-8x 5000 70 1050 6234 5611 33.1 34.8 179 BXRC-50C4001-D-8x 5000 70 850 4196 3777 27.7 23.5 178 BXRC-50E4001-B-8x 5000 80 700 4011 3610 33.1 23.2 173 BXRC-50E4001-C-8x 5000 80 1050 5997 5397 33.1 34.8 172 BXRC-50E4001-D-8x 5000 80 850 4037 3633 27.7 23.5 172 BXRC-50G4001-B-8x 5000 90 700 3467 3120 33.1 23.2 150 BXRC-50G4001-C-8x 5000 90 1050 5184 4666 33.1 34.8 149 BXRC-50G4001-D-8x 5000 90 850 3489 3141 27.7 23.5 148 BXRC-57C4001-B-8x 5700 70 700 4056 3650 33.1 23.2 175 BXRC-57C4001-C-8x 5700 70 1050 6065 5458 33.1 34.8 174 BXRC-57C4001-D-8x 5700 70 850 4082 3674 27.7 23.5 174 BXRC-57E4001-B-8x 5700 80 700 3852 3467 33.1 23.2 166 BXRC-57E4001-C-8x 5700 80 1050 5760 5184 33.1 34.8 166 BXRC-57E4001-D-8x 5700 80 850 3877 3489 27.7 23.5 165 BXRC-65C4001-B-8x 6500 70 700 4056 3650 33.1 23.2 175 BXRC-65C4001-C-8x 6500 70 1050 6065 5458 33.1 34.8 174 BXRC-65C4001-D-8x 6500 70 850 4082 3674 27.7 23.5 174 BXRC-65E4001-B-8x 6500 80 700 3897 3508 33.1 23.2 168 BXRC-65E4001-C-8x 6500 80 1050 5828 5245 33.1 34.8 168 BXRC-65E4001-D-8x 6500 80 850 3923 3531 27.7 23.5 167 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ±3 tolerance for all CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3. Table 3: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-27E4000-B-8x 80 BXRC-27E4000-C-8x 80 BXRC-27E4000-D-8x 80 BXRC-27G4000-B-8x 90 BXRC-27G4000-C-8x 90 BXRC-27G4000-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 2115 3065 4028 5053 7600 10500 3162 4570 6024 6616 11365 15700 2128 3141 4055 4901 7650 10845 1745 2529 3323 4169 6270 8662 2609 3770 4969 5458 9376 12953 1756 2591 3345 4043 6311 8947 1903 2759 3625 4548 6840 9450 2846 4113 5421 5954 10228 14130 1916 2827 3649 4411 6885 9761 1570 2276 2991 3752 5643 7796 2348 3393 4472 4912 8438 11658 1580 2332 3011 3639 5680 8053 185 175 170 163 151 140 184 175 169 166 150 139 184 174 169 163 150 138 153 145 140 134 125 115 152 144 140 137 124 115 152 144 140 135 124 114 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 7 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G40H0-B-8x 90 BXRC-27G40H0-C-8x 90 BXRC-27G40H0-D-8x 90 BXRC-30C4001-B-8x 70 BXRC-30C4001-C-8x 70 BXRC-30C4001-D-8x 70 BXRC-30E4000-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 1820 2638 3467 4349 6541 9036 2721 3933 5184 5694 9781 13512 1832 2703 3489 4218 6584 9334 2353 3410 4481 5622 8455 11681 3518 5084 6701 7360 12643 17467 2368 3495 4511 5452 8511 12065 2247 3257 4280 5369 8075 11156 1638 2374 3120 3914 5887 8133 2449 3540 4666 5125 8803 12161 1649 2433 3141 3796 5925 8400 2117 3069 4033 5060 7610 10513 3166 4576 6031 6624 11379 15720 2131 3145 4060 4907 7660 10859 2022 2931 3852 4832 7268 10040 159 151 146 140 130 120 159 151 146 143 129 120 159 150 146 140 129 119 206 195 189 181 168 156 205 195 188 184 167 155 205 194 188 182 167 154 196 186 181 173 160 149 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E4000-C-8x 80 BXRC-30E4000-D-8x 80 BXRC-30G4000-B-8x 90 BXRC-30G4000-C-8x 90 BXRC-30G4000-D-8x 90 BXRC-30G40H0-B-8x 90 BXRC-30G40H0-C-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 3360 4856 6400 7030 12075 16682 2262 3338 4308 5207 8128 11523 1824 2644 3474 4359 6555 9056 2727 3942 5195 5706 9802 13542 1836 2709 3497 4227 6598 9354 1910 2768 3638 4564 6864 9482 2856 4127 5440 5975 10264 14179 3024 4370 5760 6327 10868 15013 2035 3004 3877 4687 7315 10371 1641 2379 3127 3923 5900 8150 2455 3548 4676 5136 8822 12187 1652 2438 3147 3804 5938 8419 1719 2492 3274 4108 6178 8534 2570 3715 4896 5378 9238 12761 196 186 180 176 160 148 196 185 180 173 160 147 159 151 147 140 130 121 159 151 146 143 130 120 159 150 146 141 130 119 167 158 153 147 136 126 166 158 153 150 136 126 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G40H0-D-8x 90 BXRC-35E4000-B-8x 80 BXRC-35E4000-C-8x 80 BXRC-35E4000-D-8x 80 BXRC-35G4000-B-8x 90 BXRC-35G4000-C-8x 90 BXRC-35G4000-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 1922 2837 3662 4426 6909 9795 2300 3334 4381 5496 8265 11418 3439 4970 6551 7195 12359 17074 2315 3416 4409 5330 8319 11794 1890 2740 3600 4517 6793 9384 2826 4085 5384 5913 10157 14032 1902 2807 3624 4380 6837 9693 1730 2553 3296 3984 6218 8815 2070 3000 3943 4946 7439 10276 3095 4473 5896 6476 11123 15367 2083 3074 3968 4797 7487 10615 1701 2466 3240 4065 6113 8446 2544 3676 4845 5322 9142 12629 1712 2527 3261 3942 6153 8724 166 158 153 147 136 125 201 191 185 177 164 152 200 190 184 180 164 152 200 190 184 178 164 151 165 157 152 145 135 125 165 156 151 148 134 125 165 156 151 146 134 124 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C4001-B-8x 70 BXRC-40C4001-C-8x 70 BXRC-40C4001-D-8x 70 BXRC-40E4000-B-8x 80 BXRC-40E4000-C-8x 80 BXRC-40E4000-D-8x 80 BXRC-40G4000-B-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 2419 3506 4607 5780 8693 12009 3617 5227 6889 7567 12999 17957 2434 3593 4637 5606 8750 12404 2313 3353 4406 5527 8313 11484 3459 4999 6588 7236 12430 17172 2328 3436 4435 5360 8367 11862 1930 2797 3676 4611 6935 9581 2177 3155 4147 5202 7824 10808 3255 4704 6200 6810 11699 16162 2191 3233 4174 5045 7875 11164 2082 3017 3965 4974 7482 10336 3113 4499 5929 6513 11187 15455 2095 3092 3991 4824 7530 10676 1737 2517 3308 4150 6242 8623 211 201 194 186 173 160 211 200 194 190 172 159 211 199 194 187 172 158 202 192 186 178 165 153 202 191 185 181 165 152 202 191 185 179 165 151 169 160 155 149 138 128 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40G4000-C-8x 90 BXRC-40G4000-D-8x 90 BXRC-50C4001-B-8x 70 BXRC-50C4001-C-8x 70 BXRC-50C4001-D-8x 70 BXRC-50E4001-B-8x 80 BXRC-50E4001-C-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 2885 4170 5496 6037 10370 14327 1942 2866 3700 4472 6981 9896 2432 3525 4632 5811 8740 12075 3636 5256 6927 7609 13070 18055 2448 3612 4663 5636 8798 12472 2339 3391 4456 5590 8408 11615 3498 5056 6664 7319 12572 17369 2597 3753 4947 5433 9333 12894 1748 2580 3330 4025 6283 8907 2189 3173 4169 5230 7866 10867 3273 4730 6234 6848 11763 16250 2203 3251 4196 5073 7918 11225 2105 3052 4011 5031 7567 10454 3148 4550 5997 6587 11315 15632 168 160 155 151 137 127 168 159 155 149 137 126 213 202 195 187 174 161 212 201 195 191 173 160 212 201 195 188 173 159 205 194 188 180 167 155 204 194 187 183 166 154 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50E4001-D-8x 80 BXRC-50G4001-B-8x 90 BXRC-50G4001-C-8x 90 BXRC-50G4001-D-8x 90 BXRC-57C4001-B-8x 70 BXRC-57C4001-C-8x 70 BXRC-57C4001-D-8x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 2355 3475 4485 5422 8463 11997 2022 2931 3852 4832 7268 10040 3024 4370 5760 6327 10868 15013 2035 3004 3877 4687 7315 10371 2366 3429 4507 5654 8503 11746 3538 5113 6739 7402 12714 17565 2381 3514 4536 5483 8558 12133 2119 3127 4037 4880 7617 10798 1820 2638 3467 4349 6541 9036 2721 3933 5184 5694 9781 13512 1832 2703 3489 4218 6584 9334 2129 3086 4056 5088 7653 10572 3184 4602 6065 6662 11443 15808 2143 3163 4082 4935 7703 10920 204 193 187 181 166 153 177 168 163 156 144 134 176 167 162 159 144 133 176 167 162 156 144 132 207 196 190 182 169 156 206 196 190 185 168 156 206 195 190 183 168 155 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E4001-B-8x 80 BXRC-57E4001-C-8x 80 BXRC-57E4001-D-8x 80 BXRC-65C4001-B-8x 70 BXRC-65C4001-C-8x 70 BXRC-65C4001-D-8x 70 BXRC-65E4001-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 350 525 700 900 1400 2000 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 32.7 33.3 33.9 34.5 36.0 37.5 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 11.4 17.5 23.7 31.0 50.4 75.1 2247 3257 4280 5369 8075 11156 3360 4856 6400 7030 12075 16682 2262 3338 4308 5207 8128 11523 2366 3429 4507 5654 8503 11746 3538 5113 6739 7402 12714 17565 2381 3514 4536 5483 8558 12133 2273 3295 4330 5432 8170 11287 2022 2931 3852 4832 7268 10040 3024 4370 5760 6327 10868 15013 2035 3004 3877 4687 7315 10371 2129 3086 4056 5088 7653 10572 3184 4602 6065 6662 11443 15808 2143 3163 4082 4935 7703 10920 2046 2966 3897 4889 7353 10158 196 186 181 173 160 149 196 186 180 176 160 148 196 185 180 173 160 147 207 196 190 182 169 156 206 196 190 185 168 156 206 195 190 183 168 155 199 189 183 175 162 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-65E4001-C-8x 80 BXRC-65E4001-D-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 525 785 1050 1170 2100 3000 425 650 850 1050 1700 2500 32.7 33.3 33.9 34.1 36.0 37.5 27.2 27.7 28.2 28.6 29.9 31.3 17.2 26.1 35.6 39.9 75.5 112.6 11.6 18.0 23.9 30.0 50.9 78.3 3399 4913 6475 7112 12217 16878 2288 3377 4359 5269 8224 11659 3059 4422 5828 6401 10996 15190 2059 3039 3923 4742 7401 10493 198 188 182 178 162 150 198 187 182 175 162 149 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Electrical Characteristics Table 4: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx400x-B-8x BXRC-xxx400x-C-8x BXRC-xxx400x-D-8x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.14 30.5 37.2 -12.10 0.23 33.7 41.1 36.4 -10.93 0.12 30.5 37.2 37.5 40.3 -12.10 0.20 33.7 41.1 26.1 28.2 30.3 -9.10 0.13 25.4 30.9 29.0 31.3 33.6 -10.10 0.22 28.1 34.3 Minimum Typical Maximum 700 31.4 33.9 36.4 -10.93 2000 34.7 37.5 40.3 1050 31.4 33.9 3000 34.7 850 2500 Notes for Table 4: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application. 16 Eye Safety Table 5: Eye Safety Risk Group (RG) Classifications Part Number CCT Drive Current (mA) 2700K/3000K 4000K2 5000K3 6500K4 1440 RG1 RG1 RG1 RG1 2000 RG1 RG1 RG1 RG2 1440 RG1 RG1 RG1 RG1 1995 RG1 RG1 RG1 RG2 2650 RG1 RG1 RG2 RG2 3000 RG1 RG2 RG2 RG2 1730 RG1 RG1 RG1 RG1 2400 RG1 RG1 RG1 RG2 2500 RG1 RG1 RG2 RG2 BXRC-xxx400x-B-8x BXRC-xxx400x-C-8x BXRC-xxx400x-D-8x Notes for Table 5: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 17 Absolute Maximum Ratings Table 6: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx400x-B-8x BXRC-xxx400x-C-8x BXRC-xxx400x-D-8x Maximum Drive Current3 2000 mA 3000 mA 2500 mA Maximum Peak Pulsed Drive Current4 2240 mA 3360 mA 2800 mA Maximum Reverse Voltage5 -60V -60V -50V Notes for Table 6: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 18 Performance Curves Figure 1: Vero 18B Drive Current vs. Voltage Figure 2: Vero 18C Drive Current vs. Voltage 38.0 38.0 37.0 36.0 Voltage (V) Voltage (V) 37.0 35.0 34.0 36.0 35.0 34.0 33.0 33.0 32.0 32.0 0 250 500 750 1000 1250 1500 1750 2000 0 2250 500 1000 Drive Current (mA) 2000 2500 3000 3500 Figure 4: Vero 18B Typical Relative Flux vs. Current Figure 3: Vero 18D Drive Current vs. Voltage 32.0 300% Relative Luminous Flux (%) 31.5 31.0 30.5 Voltage (V) 1500 Drive Current (mA) 30.0 29.5 29.0 28.5 28.0 27.5 250% 200% 150% 100% 50% 27.0 0% 26.5 0 500 1000 1500 2000 2500 0 3000 250 Figure 5: Vero 18C Typical Relative Flux vs. Current 750 1000 1250 1500 1750 2000 2250 Figure 6 Vero 18D Typical Relative Flux vs. Current 300% Relative Luminous Flux (%) 300% Relative Luminous Flux (%) 500 Drive Current (mA) Drive Current (mA) 250% 200% 150% 100% 50% 250% 200% 150% 100% 50% 0% 0% 0 500 1000 1500 2000 Drive Current (mA) 2500 3000 3500 0 500 1000 1500 2000 2500 3000 Drive Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 19 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature 102% 0.0010 100% 0.0000 -0.0010 98% -0.0020 96% ccy shift Relative Luminous Flux Figure 7: Typical DC Flux vs. Case Temperature 94% 92% -0.0030 -0.0040 -0.0050 90% -0.0060 88% -0.0070 0 20 40 60 80 100 120 0 20 Case Temperature (Tc) 60 80 100 120 Case Temperature (Tc) Figure 10: Derating Curve Figure 9: Typical DC ccx Shift vs. Case Temperature 0.0020 3500 25C Pulsed 0.0000 40 Drive Current (mA) 3000 ccx shift -0.0020 -0.0040 -0.0060 -0.0080 2500 2000 1500 1000 BXRC-xxx400x-C-8x 500 0 -0.0100 0 20 40 60 80 Case Temperature (Tc) 100 120 0 20 40 60 80 Case Temperature (Tc) 100 120 20 Typical Radiation Pattern Figure 11: Typical Spatial Radiation Pattern Note for Figure 11: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 12: Typical Polar Radiation Pattern 21 Typical Color Spectrum Figure 13: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 13: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 22 Mechanical Dimensions Figure 14: Drawing for Vero 18 LED Array Notes for Figure 14: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 23 Color Binning Information Figure 15: Warm and Neutral White Test Bins in xy Color Space 0.44 3 SDCM 2 SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 0.38 0.36 0.34 0.36 0.39 0.42 X 0.45 0.48 Note: Pulsed Test Conditions, Tc = 25°C Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4073, 0.3917) (0.3818, 0.3797) Figure 16: Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5481K - 5829K) (6270K - 6765K) 83 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 24 Packaging and Labeling Figure 17: Drawing for Vero 18 Packaging Tray Notes for Figure 17: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 25 Packaging and Labeling Figure 18: Vero Series Packaging and Labeling Notes for Figure 18: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 19: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E4000C 83 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 26 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 27 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero 18 Array Series Product Data Sheet DS422 Rev. A (07/2020) 28
BXRC-35E4000-D-83 价格&库存

很抱歉,暂时无法提供与“BXRC-35E4000-D-83”相匹配的价格&库存,您可以联系我们找货

免费人工找货