Bridgelux Gen 8 V22 Array Series
®
Product Data Sheet DS416
1
V Series
Introduction
The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package.
These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design
flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality,
low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications.
The V22 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and
energy efficiency advantages.
Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life.
Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights.
Features
• Efficacy of 182 lm/W typical, 3000K 80 CRI
• Reliable operation at up to 3x nominal current, 30%
increase in maximum lumens per LES size
• Wide selection of CCT options (2700K-6500K) with
minimum 70, 80 and 90 CRI options
• Uniform high-quality illumination
• 2 and 3 SDCM binning options (2700K – 4000K)
• Forward voltage bin codes and backside marking
• Instant light with unlimited dimming
• 5-Year warranty
Benefits
• Enables high efficiency lighting systems and lower
operating costs
• Supports the trend toward luminaire miniaturization
and delivers enhanced optical control
• Design flexibility for a broad range of lighting
applications
• Clean white light without pixelation
• Uniform consistent white light
• Design flexibility for multi-source applications
• Easy to use with daylight and motion sensors to
increase energy savings
• Design with confidence
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
7
Electrical Characteristics
16
Eye Safety
17
Absolute Maximum Ratings
18
Performance Curves
19
Typical Radiation Pattern
21
Typical Color Spectrum
22
Mechanical Dimensions
23
Color Binning Information
24
Packaging and Labeling
25
Design Resources
27
Precautions
27
Disclaimers
27
About Bridgelux
28
1
Product Feature Map
Bridgelux arrays are fully engineered devices that
provide consistent thermal and optical performance on an
engineered mechanical platform. The V Series arrays are
the most compact chip-on-board devices across all of
Bridgelux’s LED Array products. The arrays incorporate
several features to simplify design integration and
assembly. Please visit www.bridgelux.com for more
information on the V Series family of products.
Polarity symbols
Designed to comply with global
safety standards for creepage
and clearance distances
Fully engineered substrate
for consistent thermal, mechanical
and optical properties
White ring around LES
Yellow phosphor Light
Emitting Surface (LES)
Case Temperature (Tc) Measurement Point
Solder Pads
Note: Part number and lot codes are scribed on back of array
Product Nomenclature
The part number designation for Bridgelux V Series LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRE – 30 E 650 0 – C –
83
CCT Bin Options
Product Family
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen. 8
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Décor Series Showcase Target
Flux Indicator
650x = 6500 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRE-27E6500-B-8x
2700
80
950
8171
7354
50.2
47.7
171
BXRE-27E6500-C-8x
2700
80
1200
10424
9382
50.7
60.8
171
BXRE-27E6500-D-8x
2700
80
1050
6030
5427
33.5
35.2
171
BXRE-27G6500-B-8x
2700
90
950
6741
6067
50.2
47.7
141
141
BXRE-27G6500-C-8x
2700
90
1200
8600
7740
50.7
60.8
BXRE-27G6500-D-8x
2700
90
1050
4975
4477
33.5
35.2
141
BXRE-27G65H0-B-8x
2700
90
950
7032
6329
50.2
47.7
147
BXRE-27G65H0-C-8x
2700
90
1200
8972
8074
50.7
60.8
147
BXRE-27G65H0-D-8x
2700
90
1050
5190
4671
33.5
35.2
148
BXRE-30C6501-B-8x
3000
70
950
9091
8182
50.2
47.7
191
BXRE-30C6501-C-8x
3000
70
1200
11597
10438
50.7
60.8
191
BXRE-30C6501-D-8x
3000
70
1050
6709
6038
33.5
35.2
191
BXRE-30E6500-B-8x
3000
80
950
8682
7814
50.2
47.7
182
182
BXRE-30E6500-C-8x
3000
80
1200
11076
9968
50.7
60.8
BXRE-30E6500-D-8x
3000
80
1050
6407
5766
33.5
35.2
182
BXRE-30G6500-B-8x
3000
90
950
7048
6343
50.2
47.7
148
BXRE-30G6500-C-8x
3000
90
1200
8991
8092
50.7
60.8
148
BXRE-30G6500-D-8x
3000
90
1050
5201
4681
33.5
35.2
148
BXRE-30G65H0-B-8x
3000
90
950
7380
6642
50.2
47.7
155
BXRE-30G65H0-C-8x
3000
90
1200
9415
8473
50.7
60.8
155
BXRE-30G65H0-D-8x
3000
90
1050
5446
4901
33.5
35.2
155
BXRE-35E6500-B-8x
3500
80
950
8886
7998
50.2
47.7
186
BXRE-35E6500-C-8x
3500
80
1200
11337
10203
50.7
60.8
186
BXRE-35E6500-D-8x
3500
80
1050
6558
5902
33.5
35.2
186
BXRE-35G6500-B-8x
3500
90
950
7303
6573
50.2
47.7
153
BXRE-35G6500-C-8x
3500
90
1200
9317
8385
50.7
60.8
153
BXRE-35G6500-D-8x
3500
90
1050
5389
4850
33.5
35.2
153
BXRE-40C6501-B-8x
4000
70
950
9346
8411
50.2
47.7
196
BXRE-40C6501-C-8x
4000
70
1200
11923
10731
50.7
60.8
196
BXRE-40C6501-D-8x
4000
70
1050
6897
6207
33.5
35.2
196
BXRE-40E6500-B-8x
4000
80
950
8937
8044
50.2
47.7
187
BXRE-40E6500-C-8x
4000
80
1200
11402
10262
50.7
60.8
187
BXRE-40E6500-D-8x
4000
80
1050
6595
5936
33.5
35.2
188
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux
maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
3
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
90
950
90
1200
4000
90
1050
5502
5000
70
950
9397
5000
70
1200
11988
BXRE-50C6501-D-8x
5000
70
1050
BXRE-50E6501-B-8x
5000
80
BXRE-50E6501-C-8x
5000
Part Number
Nominal
CCT1
(K)
CRI
BXRE-40G6500-B-8x
4000
BXRE-40G6500-C-8x
4000
BXRE-40G6500-D-8x
BXRE-50C6501-B-8x
BXRE-50C6501-C-8x
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
7456
6711
9512
8561
Typical
Power
(W)
Typical
Efficacy
(lm/W)
50.2
47.7
156
50.7
60.8
156
4952
33.5
35.2
156
8457
50.2
47.7
197
10789
50.7
60.8
197
6935
6241
33.5
35.2
197
950
9039
8136
50.2
47.7
190
80
1200
11532
10379
50.7
60.8
190
2
BXRE-50E6501-D-8x
5000
80
1050
6671
6004
33.5
35.2
190
BXRE-50G6501-B-8x
5000
90
950
7814
7032
50.2
47.7
164
BXRE-50G6501-C-8x
5000
90
1200
9968
8972
50.7
60.8
164
BXRE-50G6501-D-8x
5000
90
1050
5766
5190
33.5
35.2
164
BXRE-57C6501-B-8x
5700
70
950
9142
8227
50.2
47.7
192
BXRE-57C6501-C-8x
5700
70
1200
11662
10496
50.7
60.8
192
BXRE-57C6501-D-8x
5700
70
1050
6746
6072
33.5
35.2
192
BXRE-57E6501-B-8x
5700
80
950
8682
7814
50.2
47.7
182
BXRE-57E6501-C-8x
5700
80
1200
11076
9968
50.7
60.8
182
BXRE-57E6501-D-8x
5700
80
1050
6407
5766
33.5
35.2
182
BXRE-65C6501-B-8x
6500
70
950
9142
8227
50.2
47.7
192
BXRE-65C6501-C-8x
6500
70
1200
11662
10496
50.7
60.8
192
BXRE-65C6501-D-8x
6500
70
1050
6746
6072
33.5
35.2
192
BXRE-65E6501-B-8x
6500
80
950
8784
7906
50.2
47.7
184
BXRE-65E6501-C-8x
6500
80
1200
11206
10086
50.7
60.8
184
BXRE-65E6501-D-8x
6500
80
1050
6482
5834
33.5
35.2
184
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
4
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRE-27E6500-B-8x
2700
80
950
7354
6619
49.2
46.8
157
BXRE-27E6500-C-8x
2700
80
1200
9382
8444
49.7
59.7
157
BXRE-27E6500-D-8x
2700
80
1050
5427
4884
33.0
34.6
157
BXRE-27G6500-B-8x
2700
90
950
6067
5460
49.2
46.8
130
BXRE-27G6500-C-8x
2700
90
1200
7740
6966
49.7
59.7
130
BXRE-27G6500-D-8x
2700
90
1050
4477
4030
33.0
34.6
129
BXRE-27G65H0-B-8x
2700
90
950
6329
5696
49.2
46.8
135
BXRE-27G65H0-C-8x
2700
90
1200
8074
7267
49.7
59.7
135
BXRE-27G65H0-D-8x
2700
90
1050
4671
4204
33.0
34.6
135
BXRE-30C6501-B-8x
3000
70
950
8182
7363
49.2
46.8
175
BXRE-30C6501-C-8x
3000
70
1200
10438
9394
49.7
59.7
175
BXRE-30C6501-D-8x
3000
70
1050
6038
5434
33.0
34.6
175
BXRE-30E6500-B-8x
3000
80
950
7814
7032
49.2
46.8
167
BXRE-30E6500-C-8x
3000
80
1200
9968
8972
49.7
59.7
167
BXRE-30E6500-D-8x
3000
80
1050
5766
5190
33.0
34.6
167
BXRE-30G6500-B-8x
3000
90
950
6343
5709
49.2
46.8
136
BXRE-30G6500-C-8x
3000
90
1200
8092
7283
49.7
59.7
136
BXRE-30G6500-D-8x
3000
90
1050
4681
4213
33.0
34.6
135
BXRE-30G65H0-B-8x
3000
90
950
6642
5978
49.2
46.8
142
BXRE-30G65H0-C-8x
3000
90
1200
8473
7626
49.7
59.7
142
BXRE-30G65H0-D-8x
3000
90
1050
4901
4411
33.0
34.6
142
BXRE-35E6500-B-8x
3500
80
950
7998
7198
49.2
46.8
171
BXRE-35E6500-C-8x
3500
80
1200
10203
9183
49.7
59.7
171
BXRE-35E6500-D-8x
3500
80
1050
5902
5312
33.0
34.6
171
BXRE-35G6500-B-8x
3500
90
950
6573
5916
49.2
46.8
140
BXRE-35G6500-C-8x
3500
90
1200
8385
7547
49.7
59.7
140
BXRE-35G6500-D-8x
3500
90
1050
4850
4365
33.0
34.6
140
BXRE-40C6501-B-8x
4000
70
950
8411
7570
49.2
46.8
180
BXRE-40C6501-C-8x
4000
70
1200
10731
9658
49.7
59.7
180
BXRE-40C6501-D-8x
4000
70
1050
6207
5587
33.0
34.6
179
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux
maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRE-40E6500-B-8x
4000
80
950
8044
7239
49.2
46.8
172
BXRE-40E6500-C-8x
4000
80
1200
10262
9235
49.7
59.7
172
BXRE-40E6500-D-8x
4000
80
1050
5936
5342
33.0
34.6
172
BXRE-40G6500-B-8x
4000
90
950
6711
6040
49.2
46.8
143
BXRE-40G6500-C-8x
4000
90
1200
8561
7705
49.7
59.7
143
BXRE-40G6500-D-8x
4000
90
1050
4952
4457
33.0
34.6
143
BXRE-50C6501-B-8x
5000
70
950
8457
7612
49.2
46.8
181
BXRE-50C6501-C-8x
5000
70
1200
10789
9710
49.7
59.7
181
BXRE-50C6501-D-8x
5000
70
1050
6241
5617
33.0
34.6
180
BXRE-50E6501-B-8x
5000
80
950
8136
7322
49.2
46.8
174
174
BXRE-50E6501-C-8x
5000
80
1200
10379
9341
49.7
59.7
BXRE-50E6501-D-8x
5000
80
1050
6004
5403
33.0
34.6
174
BXRE-50G6501-B-8x
5000
90
950
7032
6329
49.2
46.8
150
BXRE-50G6501-C-8x
5000
90
1200
8972
8074
49.7
59.7
150
BXRE-50G6501-D-8x
5000
90
1050
5190
4671
33.0
34.6
150
BXRE-57C6501-B-8x
5700
70
950
8227
7405
49.2
46.8
176
176
BXRE-57C6501-C-8x
5700
70
1200
10496
9447
49.7
59.7
BXRE-57C6501-D-8x
5700
70
1050
6072
5464
33.0
34.6
175
BXRE-57E6501-B-8x
5700
80
950
7814
7032
49.2
46.8
167
BXRE-57E6501-C-8x
5700
80
1200
9968
8972
49.7
59.7
167
BXRE-57E6501-D-8x
5700
80
1050
5766
5190
33.0
34.6
167
BXRE-65C6501-B-8x
6500
70
950
8227
7405
49.2
46.8
176
BXRE-65C6501-C-8x
6500
70
1200
10496
9447
49.7
59.7
176
BXRE-65C6501-D-8x
6500
70
1050
6072
5464
33.0
34.6
175
BXRE-65E6501-B-8x
6500
80
950
7906
7115
49.2
46.8
169
BXRE-65E6501-C-8x
6500
80
1200
10086
9077
49.7
59.7
169
BXRE-65E6501-D-8x
6500
80
1050
5834
5251
33.0
34.6
169
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains
a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Performance at Commonly Used Drive Currents
V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3.
Table 3: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRE-27E6500-B-8x
80
BXRE-27E6500-C-8x
80
BXRE-27E6500-D-8x
80
BXRE-27G6500-B-8x
90
BXRE-27G6500-C-8x
90
BXRE-27G6500-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
4179
6304
8171
9982
15730
25425
5332
7908
10424
12423
20067
28223
3084
4560
6030
7943
11608
18347
3448
5201
6741
8235
12977
20975
4399
6524
8600
10249
16556
23284
2545
3762
4975
6553
9577
15136
3761
5673
7354
8984
14157
22882
4799
7117
9382
11181
18061
25401
2776
4104
5427
7149
10447
16512
3103
4681
6067
7412
11680
18878
3959
5871
7740
9224
14900
20955
2290
3386
4477
5898
8619
13622
181
176
171
168
156
139
181
176
171
168
156
145
181
176
171
166
156
140
149
145
141
138
129
115
149
145
141
139
129
119
149
145
141
137
129
115
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
7
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-27G65H0-B-8x
90
BXRE-27G65H0-C-8x
90
BXRE-27G65H0-D-8x
90
BXRE-30C6501-B-8x
70
BXRE-30C6501-C-8x
70
BXRE-30C6501-D-8x
70
BXRE-30E6500-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
3597
5425
7032
8591
13538
21881
4589
6806
8972
10692
17271
24289
2654
3925
5190
6836
9990
15790
4650
7013
9091
11105
17500
28285
5932
8797
11597
13821
22325
31398
3431
5073
6709
8837
12914
20411
4441
6698
8682
10606
16713
27014
3237
4883
6329
7732
12184
19693
4130
6125
8074
9623
15544
21860
2389
3532
4671
6152
8991
14211
4185
6312
8182
9994
15750
25456
5339
7918
10438
12439
20093
28258
3088
4566
6038
7953
11623
18370
3997
6028
7814
9545
15042
24312
156
151
147
144
134
119
156
151
147
145
134
124
156
151
147
143
134
120
201
195
191
187
174
154
201
196
191
187
174
161
201
196
191
185
174
156
192
187
182
178
166
147
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-30E6500-C-8x
80
BXRE-30E6500-D-8x
80
BXRE-30G6500-B-8x
90
BXRE-30G6500-C-8x
90
BXRE-30G6500-D-8x
90
BXRE-30G65H0-B-8x
90
BXRE-30G65H0-C-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
5665
8402
11076
13200
21322
29987
3277
4845
6407
8439
12334
19493
3605
5437
7048
8609
13567
21929
4599
6820
8991
10715
17308
24342
2660
3933
5201
6851
10012
15824
3775
5693
7380
9015
14206
22962
4815
7142
9415
11220
18123
25489
5099
7562
9968
11880
19190
26988
2949
4361
5766
7596
11100
17544
3244
4893
6343
7748
12210
19736
4139
6138
8092
9644
15577
21908
2394
3540
4681
6166
9011
14242
3397
5124
6642
8113
12786
20665
4334
6427
8473
10098
16311
22940
192
187
182
179
166
154
192
187
182
176
166
149
156
151
148
145
135
120
156
152
148
145
135
125
156
152
148
143
135
121
163
159
155
151
141
125
163
159
155
152
141
131
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
9
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-30G65H0-D-8x
90
BXRE-35E6500-B-8x
80
BXRE-35E6500-C-8x
80
BXRE-35E6500-D-8x
80
BXRE-35G6500-B-8x
90
BXRE-35G6500-C-8x
90
BXRE-35G6500-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
2785
4118
5446
7174
10484
16569
4545
6855
8886
10855
17106
27649
5798
8600
11337
13510
21823
30692
3354
4959
6558
8638
12624
19952
3735
5634
7303
8921
14059
22723
4765
7067
9317
11103
17935
25224
2757
4076
5389
7099
10375
16397
2507
3707
4901
6456
9435
14912
4091
6170
7998
9770
15396
24884
5219
7740
10203
12159
19641
27623
3019
4463
5902
7774
11362
17957
3362
5071
6573
8029
12653
20451
4289
6361
8385
9993
16142
22702
2481
3668
4850
6389
9337
14758
163
159
155
150
141
126
197
191
186
182
170
151
197
191
186
183
170
157
197
191
186
181
170
152
162
157
153
150
140
124
162
157
153
150
140
129
162
157
153
148
140
125
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-40C6501-B-8x
70
BXRE-40C6501-C-8x
70
BXRE-40C6501-D-8x
70
BXRE-40E6500-B-8x
80
BXRE-40E6500-C-8x
80
BXRE-40E6500-D-8x
80
BXRE-40G6500-B-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
4780
7210
9346
11417
17991
29079
6098
9044
11923
14209
22952
32280
3528
5216
6897
9085
13277
20984
4571
6895
8937
10918
17205
27808
5832
8649
11402
13588
21949
30869
3373
4988
6595
8688
12696
20067
3814
5752
7456
9109
14354
23200
4302
6489
8411
10275
16192
26171
5489
8140
10731
12788
20657
29052
3175
4694
6207
8176
11949
18886
4114
6205
8044
9826
15484
25027
5249
7784
10262
12229
19754
27782
3036
4489
5936
7819
11427
18060
3432
5177
6711
8198
12918
20880
207
201
196
192
179
159
207
201
196
192
179
165
207
201
196
190
179
160
198
192
187
183
171
152
198
192
187
184
171
158
198
192
187
182
171
153
165
160
156
153
143
127
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-40G6500-C-8x
90
BXRE-40G6500-D-8x
90
BXRE-50C6501-B-8x
70
BXRE-50C6501-C-8x
70
BXRE-50C6501-D-8x
70
BXRE-50E6501-B-8x
80
BXRE-50E6501-C-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
4865
7216
9512
11336
18312
25753
2814
4161
5502
7248
10592
16741
4806
7249
9397
11479
18090
29238
6132
9094
11988
14287
23078
32456
3547
5244
6935
9135
13349
21099
4624
6973
9039
11042
17401
28126
5898
8748
11532
13743
22200
31222
4379
6494
8561
10203
16480
23178
2533
3745
4952
6523
9533
15067
4326
6524
8457
10331
16281
26314
5519
8184
10789
12858
20770
29211
3192
4720
6241
8221
12014
18989
4161
6276
8136
9938
15661
25313
5309
7873
10379
12369
19980
28099
165
160
156
153
143
132
165
161
156
151
143
128
208
202
197
193
180
160
208
202
197
193
180
166
208
202
197
191
180
161
200
194
189
185
173
154
200
195
189
186
173
160
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-50E6501-D-8x
80
BXRE-50G6501-B-8x
90
BXRE-50G6501-C-8x
90
BXRE-50G6501-D-8x
90
BXRE-57C6501-B-8x
70
BXRE-57C6501-C-8x
70
BXRE-57C6501-D-8x
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
3412
5045
6671
8787
12842
20296
3997
6028
7814
9545
15042
24312
5099
7562
9968
11880
19190
26988
2949
4361
5766
7596
11100
17544
4676
7052
9142
11167
17598
28444
5965
8847
11662
13899
22451
31574
3451
5102
6746
8886
12987
20525
3071
4540
6004
7908
11557
18267
3597
5425
7032
8591
13538
21881
4589
6806
8972
10692
17271
24289
2654
3925
5190
6836
9990
15790
4208
6347
8227
10051
15838
25599
5369
7962
10496
12509
20205
28417
3105
4592
6072
7998
11688
18473
200
195
189
184
173
155
173
168
164
160
149
133
173
168
164
161
149
138
173
168
164
159
149
134
202
196
192
188
175
155
202
197
192
188
175
162
202
197
192
186
175
156
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-57E6501-B-8x
80
BXRE-57E6501-C-8x
80
BXRE-57E6501-D-8x
80
BXRE-65C6501-B-8x
70
BXRE-65C6501-C-8x
70
BXRE-65C6501-D-8x
70
BXRE-65E6501-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
475
725
950
1170
1900
3250
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
48.7
49.5
50.2
50.9
53.0
56.4
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
23.1
35.9
47.7
59.5
100.7
183.1
4441
6698
8682
10606
16713
27014
5665
8402
11076
13200
21322
29987
3277
4845
6407
8439
12334
19493
4676
7052
9142
11167
17598
28444
5965
8847
11662
13899
22451
31574
3451
5102
6746
8886
12987
20525
4493
6777
8784
10731
16910
27331
3997
6028
7814
9545
15042
24312
5099
7562
9968
11880
19190
26988
2949
4361
5766
7596
11100
17544
4208
6347
8227
10051
15838
25599
5369
7962
10496
12509
20205
28417
3105
4592
6072
7998
11688
18473
4044
6099
7906
9658
15219
24598
192
187
182
178
166
147
192
187
182
179
166
154
192
187
182
176
166
149
202
196
192
188
175
155
202
197
192
188
175
162
202
197
192
186
175
156
194
189
184
180
168
149
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRE-65E6501-C-8x
80
BXRE-65E6501-D-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
600
900
1200
1440
2400
3500
525
785
1050
1400
2100
3500
49.2
50.0
50.7
51.3
53.5
55.8
32.5
33.0
33.5
34.2
35.4
37.5
29.5
45.0
60.9
73.9
128.5
195.3
17.1
25.9
35.2
47.8
74.3
131.3
5732
8501
11206
13355
21573
30340
3316
4902
6482
8539
12479
19723
5159
7651
10086
12020
19415
27306
2984
4412
5834
7685
11231
17751
194
189
184
181
168
155
194
189
184
178
168
150
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Electrical Characteristics
Table 4: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRE-xxx650x-B-8x
BXRE-xxx650x-C-8x
BXRE-xxx650x-D-8x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.07
45.1
55.0
-18.19
0.13
50.7
61.8
54.5
-16.35
0.08
45.6
55.6
55.8
60.0
-18.00
0.15
50.2
61.2
31.0
33.5
36.0
-10.81
0.08
30.1
36.7
34.7
37.5
40.3
-12.10
0.14
33.7
41.1
Minimum
Typical
Maximum
950
46.4
50.2
54.0
-16.19
3250
52.2
56.4
60.6
1200
46.9
50.7
3500
51.6
1050
3500
Notes for Table 4:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working
voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
16
Eye Safety
Table 5: Eye Safety Risk Group (RG) Classifications
Part Number
BXRE-xxx650x-B-8x
BXRE-xxx650x-C-8x
BXRE-xxx650x-D-8x
CCT
Drive Current
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1370
RG1
RG1
RG1
RG1
1900
RG1
RG1
RG1
RG2
2525
RG1
RG1
RG2
RG2
3250
RG1
RG2
RG2
RG2
1355
RG1
RG1
RG1
RG1
1880
RG1
RG1
RG1
RG2
2500
RG1
RG1
RG2
RG2
3500
RG1
RG2
RG2
RG2
2055
RG1
RG1
RG1
RG1
2850
RG1
RG1
RG1
RG2
3500
RG1
RG1
RG2
RG2
Notes for Table 5:
1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1980 lx.
3. For products classified as RG2 at 5000K Ethr= 1530 lx.
4. For products classified as RG2 at 6500K, Ethr= 1170 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
17
Absolute Maximum Ratings
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of
6 seconds
BXRE-xxx650x-B-8x
BXRE-xxx650x-C-8x
BXRE-xxx650x-D-8x
Maximum Drive Current3
3250 mA
3500 mA
3500 mA
Maximum Peak Pulsed Drive Current4
3640 mA
3920 mA
3920 mA
Maximum Reverse Voltage5
-90V
-90V
-60V
Notes for Table 6:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays
3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
18
Performance Curves
Figure 2: V22C Drive Current vs. Voltage
57.0
57.0
56.0
56.0
55.0
55.0
54.0
54.0
Voltage (V)
Voltage (V)
Figure 1: V22B Drive Current vs. Voltage
53.0
52.0
51.0
53.0
52.0
51.0
50.0
50.0
49.0
49.0
48.0
48.0
0
500
1000
1500
2000
2500
3000
0
3500
500
1000
38.0
2500
3000
3500
4000
Relative Luminous Flux (%)
350%
37.0
Voltage (V)
2000
Figure 4: V22B Typical Relative Flux vs. Current
Figure 3: V22D Drive Current vs. Voltage
36.0
35.0
34.0
33.0
32.0
0
500
1000
1500
2000
2500
3000
3500
300%
250%
200%
150%
100%
50%
0%
4000
0
500
1000
Drive Current (mA)
1500
2000
2500
3000
3500
Drive Current (mA)
Figure 6: V22D Typical Relative Flux vs. Current
Figure 5: V22C Typical Relative Flux vs. Current
300%
350%
Relative Luminous Flux (%)
Relative Luminous Flux (%)
1500
Drive Current (mA)
Drive Current (mA)
250%
200%
150%
100%
50%
0%
0
500
1000
1500
2000
2500
Drive Current (mA)
3000
3500
4000
300%
250%
200%
150%
100%
50%
0%
0
500
1000
1500
2000
2500
3000
3500
4000
Drive Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
19
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
102%
0.0010
100%
0.0000
98%
-0.0010
96%
-0.0020
ccy shift
Relative Luminous Flux
Figure 7: Typical DC Flux vs. Case Temperature
94%
92%
25C Pulsed
-0.0030
-0.0040
90%
-0.0050
88%
-0.0060
-0.0070
86%
0
20
40
60
80
100
0
120
20
Figure 9: Typical DC ccx Shift vs. Case Temperature
80
100
120
100
120
Figure 10: Derating Curve
0.0020
4000
25C Pulsed
Drive Current (mA)
3500
-0.0020
ccx shift
60
Case Temperature (Tc)
Case Temperature (Tc)
0.0000
40
-0.0040
-0.0060
-0.0080
3000
2500
2000
1500
1000
BXRE-xxx650x-B-8x
500
BXRE-xxx650x-C-8x
0
-0.0100
0
20
40
60
80
Case Temperature (Tc)
100
120
0
20
40
60
80
Case Temperature (Tc)
20
Typical Radiation Pattern
Figure 11: Typical Spatial Radiation Pattern
Note for Figure 11:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 12: Typical Polar Radiation Pattern
21
Typical Color Spectrum
Figure 13: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 13:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
22
Mechanical Dimensions
Figure 14: Drawing for V22 LED Array
Notes for Figure 14:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Solder pad labeled “+” denotes positive contact.
5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations.
6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
23
Color Binning Information
Figure 15: Graph of Warm and Neutral White Test Bins in xy Color Space
Note: Pulsed Test Conditions, Tc = 25°C
Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
2700K
3000K
3500K
4000K
ANSI Bin
(for reference only)
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
83 (3 SDCM)
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
82 (2 SDCM)
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Figure 16: Graph of Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5312K - 6022K)
(6022K - 7042K)
84 (4 SDCM)
(4801K - 5282K)
(5481K - 5829K)
(6270K - 6765K)
83 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3287, 0.3417)
(0.3123, 0.3282)
24
Packaging and Labeling
Figure 17: Drawing for V22 Packaging Tube
8
Notes for Figure 17:
1. Each tube holds 15 V22 COB arrays.
2. Four tubes are sealed in an anti-static bag. Four bags are placed in a shipping box and shipped. Depending on quantities ordered, a bigger shipping box,
containing four boxes may be used to ship products.
3. Each bag and box is to be labeled as shown above.
4. Dimensions for each tube are 30.7 (W) x 9.65(H) x 460(L). Dimensions for the anti-static bag are 120mm (W) x 635mm (L) x 0.1 (T) mm. Dimensions for the
shipping box are 58.7 x 13.3 x 7.9 cm.
25
Packaging and Labeling
Figure 18: Gen. 8 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E6500C 83 2F
Internal Bin Code
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
26
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the V Series
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux V Series LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN101 for additional information.
CAUTION: RISK OF BURN
Do not touch the V Series LED array during operation.
Allow the array to cool for a sufficient period of time
before handling. The V Series LED array may reach
elevated temperatures such that could burn skin when
touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area).
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
27
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are
registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 8 V22 Array Series Product Data Sheet DS416 Rev. A (06/2020)
28