BXRE-40E6500-D-83

BXRE-40E6500-D-83

  • 厂商:

    BRIDGELUX

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
BXRE-40E6500-D-83 数据手册
Bridgelux Gen 8 V22 Array Series ® Product Data Sheet DS416 1 V Series Introduction The V Series™ LED Array products deliver high quality light in a compact and cost-effective solid-state lighting package. These chip on board (CoB) arrays can be efficiently driven up to three times the nominal drive current, enabling design flexibility not previously possible. These high flux density light sources are designed to support a wide range of high quality, low cost directional luminaires and replacement lamps for both interior and exterior commercial and residential applications. The V22 LED Array is available in a variety of electrical, CCT, and CRI combinations providing substantial design flexibility and energy efficiency advantages. Lighting system designs incorporating these LED arrays deliver increased system level efficacy and a longer service life. Typical applications include replacement lamps and task, accent, spot, track, wide area, security, wall packs and down lights. Features • Efficacy of 182 lm/W typical, 3000K 80 CRI • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options • Uniform high-quality illumination • 2 and 3 SDCM binning options (2700K – 4000K) • Forward voltage bin codes and backside marking • Instant light with unlimited dimming • 5-Year warranty Benefits • Enables high efficiency lighting systems and lower operating costs • Supports the trend toward luminaire miniaturization and delivers enhanced optical control • Design flexibility for a broad range of lighting applications • Clean white light without pixelation • Uniform consistent white light • Design flexibility for multi-source applications • Easy to use with daylight and motion sensors to increase energy savings • Design with confidence Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 7 Electrical Characteristics 16 Eye Safety 17 Absolute Maximum Ratings 18 Performance Curves 19 Typical Radiation Pattern 21 Typical Color Spectrum 22 Mechanical Dimensions 23 Color Binning Information 24 Packaging and Labeling 25 Design Resources 27 Precautions 27 Disclaimers 27 About Bridgelux 28 1 Product Feature Map Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com for more information on the V Series family of products. Polarity symbols Designed to comply with global safety standards for creepage and clearance distances Fully engineered substrate for consistent thermal, mechanical and optical properties White ring around LES Yellow phosphor Light Emitting Surface (LES) Case Temperature (Tc) Measurement Point Solder Pads Note: Part number and lot codes are scribed on back of array Product Nomenclature The part number designation for Bridgelux V Series LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRE – 30 E 650 0 – C – 83 CCT Bin Options Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 8 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Décor Series Showcase Target Flux Indicator 650x = 6500 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-27E6500-B-8x 2700 80 950 8171 7354 50.2 47.7 171 BXRE-27E6500-C-8x 2700 80 1200 10424 9382 50.7 60.8 171 BXRE-27E6500-D-8x 2700 80 1050 6030 5427 33.5 35.2 171 BXRE-27G6500-B-8x 2700 90 950 6741 6067 50.2 47.7 141 141 BXRE-27G6500-C-8x 2700 90 1200 8600 7740 50.7 60.8 BXRE-27G6500-D-8x 2700 90 1050 4975 4477 33.5 35.2 141 BXRE-27G65H0-B-8x 2700 90 950 7032 6329 50.2 47.7 147 BXRE-27G65H0-C-8x 2700 90 1200 8972 8074 50.7 60.8 147 BXRE-27G65H0-D-8x 2700 90 1050 5190 4671 33.5 35.2 148 BXRE-30C6501-B-8x 3000 70 950 9091 8182 50.2 47.7 191 BXRE-30C6501-C-8x 3000 70 1200 11597 10438 50.7 60.8 191 BXRE-30C6501-D-8x 3000 70 1050 6709 6038 33.5 35.2 191 BXRE-30E6500-B-8x 3000 80 950 8682 7814 50.2 47.7 182 182 BXRE-30E6500-C-8x 3000 80 1200 11076 9968 50.7 60.8 BXRE-30E6500-D-8x 3000 80 1050 6407 5766 33.5 35.2 182 BXRE-30G6500-B-8x 3000 90 950 7048 6343 50.2 47.7 148 BXRE-30G6500-C-8x 3000 90 1200 8991 8092 50.7 60.8 148 BXRE-30G6500-D-8x 3000 90 1050 5201 4681 33.5 35.2 148 BXRE-30G65H0-B-8x 3000 90 950 7380 6642 50.2 47.7 155 BXRE-30G65H0-C-8x 3000 90 1200 9415 8473 50.7 60.8 155 BXRE-30G65H0-D-8x 3000 90 1050 5446 4901 33.5 35.2 155 BXRE-35E6500-B-8x 3500 80 950 8886 7998 50.2 47.7 186 BXRE-35E6500-C-8x 3500 80 1200 11337 10203 50.7 60.8 186 BXRE-35E6500-D-8x 3500 80 1050 6558 5902 33.5 35.2 186 BXRE-35G6500-B-8x 3500 90 950 7303 6573 50.2 47.7 153 BXRE-35G6500-C-8x 3500 90 1200 9317 8385 50.7 60.8 153 BXRE-35G6500-D-8x 3500 90 1050 5389 4850 33.5 35.2 153 BXRE-40C6501-B-8x 4000 70 950 9346 8411 50.2 47.7 196 BXRE-40C6501-C-8x 4000 70 1200 11923 10731 50.7 60.8 196 BXRE-40C6501-D-8x 4000 70 1050 6897 6207 33.5 35.2 196 BXRE-40E6500-B-8x 4000 80 950 8937 8044 50.2 47.7 187 BXRE-40E6500-C-8x 4000 80 1200 11402 10262 50.7 60.8 187 BXRE-40E6500-D-8x 4000 80 1050 6595 5936 33.5 35.2 188 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 3 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) 90 950 90 1200 4000 90 1050 5502 5000 70 950 9397 5000 70 1200 11988 BXRE-50C6501-D-8x 5000 70 1050 BXRE-50E6501-B-8x 5000 80 BXRE-50E6501-C-8x 5000 Part Number Nominal CCT1 (K) CRI BXRE-40G6500-B-8x 4000 BXRE-40G6500-C-8x 4000 BXRE-40G6500-D-8x BXRE-50C6501-B-8x BXRE-50C6501-C-8x Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) 7456 6711 9512 8561 Typical Power (W) Typical Efficacy (lm/W) 50.2 47.7 156 50.7 60.8 156 4952 33.5 35.2 156 8457 50.2 47.7 197 10789 50.7 60.8 197 6935 6241 33.5 35.2 197 950 9039 8136 50.2 47.7 190 80 1200 11532 10379 50.7 60.8 190 2 BXRE-50E6501-D-8x 5000 80 1050 6671 6004 33.5 35.2 190 BXRE-50G6501-B-8x 5000 90 950 7814 7032 50.2 47.7 164 BXRE-50G6501-C-8x 5000 90 1200 9968 8972 50.7 60.8 164 BXRE-50G6501-D-8x 5000 90 1050 5766 5190 33.5 35.2 164 BXRE-57C6501-B-8x 5700 70 950 9142 8227 50.2 47.7 192 BXRE-57C6501-C-8x 5700 70 1200 11662 10496 50.7 60.8 192 BXRE-57C6501-D-8x 5700 70 1050 6746 6072 33.5 35.2 192 BXRE-57E6501-B-8x 5700 80 950 8682 7814 50.2 47.7 182 BXRE-57E6501-C-8x 5700 80 1200 11076 9968 50.7 60.8 182 BXRE-57E6501-D-8x 5700 80 1050 6407 5766 33.5 35.2 182 BXRE-65C6501-B-8x 6500 70 950 9142 8227 50.2 47.7 192 BXRE-65C6501-C-8x 6500 70 1200 11662 10496 50.7 60.8 192 BXRE-65C6501-D-8x 6500 70 1050 6746 6072 33.5 35.2 192 BXRE-65E6501-B-8x 6500 80 950 8784 7906 50.2 47.7 184 BXRE-65E6501-C-8x 6500 80 1200 11206 10086 50.7 60.8 184 BXRE-65E6501-D-8x 6500 80 1050 6482 5834 33.5 35.2 184 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 4 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-27E6500-B-8x 2700 80 950 7354 6619 49.2 46.8 157 BXRE-27E6500-C-8x 2700 80 1200 9382 8444 49.7 59.7 157 BXRE-27E6500-D-8x 2700 80 1050 5427 4884 33.0 34.6 157 BXRE-27G6500-B-8x 2700 90 950 6067 5460 49.2 46.8 130 BXRE-27G6500-C-8x 2700 90 1200 7740 6966 49.7 59.7 130 BXRE-27G6500-D-8x 2700 90 1050 4477 4030 33.0 34.6 129 BXRE-27G65H0-B-8x 2700 90 950 6329 5696 49.2 46.8 135 BXRE-27G65H0-C-8x 2700 90 1200 8074 7267 49.7 59.7 135 BXRE-27G65H0-D-8x 2700 90 1050 4671 4204 33.0 34.6 135 BXRE-30C6501-B-8x 3000 70 950 8182 7363 49.2 46.8 175 BXRE-30C6501-C-8x 3000 70 1200 10438 9394 49.7 59.7 175 BXRE-30C6501-D-8x 3000 70 1050 6038 5434 33.0 34.6 175 BXRE-30E6500-B-8x 3000 80 950 7814 7032 49.2 46.8 167 BXRE-30E6500-C-8x 3000 80 1200 9968 8972 49.7 59.7 167 BXRE-30E6500-D-8x 3000 80 1050 5766 5190 33.0 34.6 167 BXRE-30G6500-B-8x 3000 90 950 6343 5709 49.2 46.8 136 BXRE-30G6500-C-8x 3000 90 1200 8092 7283 49.7 59.7 136 BXRE-30G6500-D-8x 3000 90 1050 4681 4213 33.0 34.6 135 BXRE-30G65H0-B-8x 3000 90 950 6642 5978 49.2 46.8 142 BXRE-30G65H0-C-8x 3000 90 1200 8473 7626 49.7 59.7 142 BXRE-30G65H0-D-8x 3000 90 1050 4901 4411 33.0 34.6 142 BXRE-35E6500-B-8x 3500 80 950 7998 7198 49.2 46.8 171 BXRE-35E6500-C-8x 3500 80 1200 10203 9183 49.7 59.7 171 BXRE-35E6500-D-8x 3500 80 1050 5902 5312 33.0 34.6 171 BXRE-35G6500-B-8x 3500 90 950 6573 5916 49.2 46.8 140 BXRE-35G6500-C-8x 3500 90 1200 8385 7547 49.7 59.7 140 BXRE-35G6500-D-8x 3500 90 1050 4850 4365 33.0 34.6 140 BXRE-40C6501-B-8x 4000 70 950 8411 7570 49.2 46.8 180 BXRE-40C6501-C-8x 4000 70 1200 10731 9658 49.7 59.7 180 BXRE-40C6501-D-8x 4000 70 1050 6207 5587 33.0 34.6 179 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRE-40E6500-B-8x 4000 80 950 8044 7239 49.2 46.8 172 BXRE-40E6500-C-8x 4000 80 1200 10262 9235 49.7 59.7 172 BXRE-40E6500-D-8x 4000 80 1050 5936 5342 33.0 34.6 172 BXRE-40G6500-B-8x 4000 90 950 6711 6040 49.2 46.8 143 BXRE-40G6500-C-8x 4000 90 1200 8561 7705 49.7 59.7 143 BXRE-40G6500-D-8x 4000 90 1050 4952 4457 33.0 34.6 143 BXRE-50C6501-B-8x 5000 70 950 8457 7612 49.2 46.8 181 BXRE-50C6501-C-8x 5000 70 1200 10789 9710 49.7 59.7 181 BXRE-50C6501-D-8x 5000 70 1050 6241 5617 33.0 34.6 180 BXRE-50E6501-B-8x 5000 80 950 8136 7322 49.2 46.8 174 174 BXRE-50E6501-C-8x 5000 80 1200 10379 9341 49.7 59.7 BXRE-50E6501-D-8x 5000 80 1050 6004 5403 33.0 34.6 174 BXRE-50G6501-B-8x 5000 90 950 7032 6329 49.2 46.8 150 BXRE-50G6501-C-8x 5000 90 1200 8972 8074 49.7 59.7 150 BXRE-50G6501-D-8x 5000 90 1050 5190 4671 33.0 34.6 150 BXRE-57C6501-B-8x 5700 70 950 8227 7405 49.2 46.8 176 176 BXRE-57C6501-C-8x 5700 70 1200 10496 9447 49.7 59.7 BXRE-57C6501-D-8x 5700 70 1050 6072 5464 33.0 34.6 175 BXRE-57E6501-B-8x 5700 80 950 7814 7032 49.2 46.8 167 BXRE-57E6501-C-8x 5700 80 1200 9968 8972 49.7 59.7 167 BXRE-57E6501-D-8x 5700 80 1050 5766 5190 33.0 34.6 167 BXRE-65C6501-B-8x 6500 70 950 8227 7405 49.2 46.8 176 BXRE-65C6501-C-8x 6500 70 1200 10496 9447 49.7 59.7 176 BXRE-65C6501-D-8x 6500 70 1050 6072 5464 33.0 34.6 175 BXRE-65E6501-B-8x 6500 80 950 7906 7115 49.2 46.8 169 BXRE-65E6501-C-8x 6500 80 1200 10086 9077 49.7 59.7 169 BXRE-65E6501-D-8x 6500 80 1050 5834 5251 33.0 34.6 169 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Performance at Commonly Used Drive Currents V Series LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3. Table 3: Product Performance at Commonly Used Drive Currents Part Number CRI BXRE-27E6500-B-8x 80 BXRE-27E6500-C-8x 80 BXRE-27E6500-D-8x 80 BXRE-27G6500-B-8x 90 BXRE-27G6500-C-8x 90 BXRE-27G6500-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 4179 6304 8171 9982 15730 25425 5332 7908 10424 12423 20067 28223 3084 4560 6030 7943 11608 18347 3448 5201 6741 8235 12977 20975 4399 6524 8600 10249 16556 23284 2545 3762 4975 6553 9577 15136 3761 5673 7354 8984 14157 22882 4799 7117 9382 11181 18061 25401 2776 4104 5427 7149 10447 16512 3103 4681 6067 7412 11680 18878 3959 5871 7740 9224 14900 20955 2290 3386 4477 5898 8619 13622 181 176 171 168 156 139 181 176 171 168 156 145 181 176 171 166 156 140 149 145 141 138 129 115 149 145 141 139 129 119 149 145 141 137 129 115 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 7 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-27G65H0-B-8x 90 BXRE-27G65H0-C-8x 90 BXRE-27G65H0-D-8x 90 BXRE-30C6501-B-8x 70 BXRE-30C6501-C-8x 70 BXRE-30C6501-D-8x 70 BXRE-30E6500-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 3597 5425 7032 8591 13538 21881 4589 6806 8972 10692 17271 24289 2654 3925 5190 6836 9990 15790 4650 7013 9091 11105 17500 28285 5932 8797 11597 13821 22325 31398 3431 5073 6709 8837 12914 20411 4441 6698 8682 10606 16713 27014 3237 4883 6329 7732 12184 19693 4130 6125 8074 9623 15544 21860 2389 3532 4671 6152 8991 14211 4185 6312 8182 9994 15750 25456 5339 7918 10438 12439 20093 28258 3088 4566 6038 7953 11623 18370 3997 6028 7814 9545 15042 24312 156 151 147 144 134 119 156 151 147 145 134 124 156 151 147 143 134 120 201 195 191 187 174 154 201 196 191 187 174 161 201 196 191 185 174 156 192 187 182 178 166 147 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-30E6500-C-8x 80 BXRE-30E6500-D-8x 80 BXRE-30G6500-B-8x 90 BXRE-30G6500-C-8x 90 BXRE-30G6500-D-8x 90 BXRE-30G65H0-B-8x 90 BXRE-30G65H0-C-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 5665 8402 11076 13200 21322 29987 3277 4845 6407 8439 12334 19493 3605 5437 7048 8609 13567 21929 4599 6820 8991 10715 17308 24342 2660 3933 5201 6851 10012 15824 3775 5693 7380 9015 14206 22962 4815 7142 9415 11220 18123 25489 5099 7562 9968 11880 19190 26988 2949 4361 5766 7596 11100 17544 3244 4893 6343 7748 12210 19736 4139 6138 8092 9644 15577 21908 2394 3540 4681 6166 9011 14242 3397 5124 6642 8113 12786 20665 4334 6427 8473 10098 16311 22940 192 187 182 179 166 154 192 187 182 176 166 149 156 151 148 145 135 120 156 152 148 145 135 125 156 152 148 143 135 121 163 159 155 151 141 125 163 159 155 152 141 131 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-30G65H0-D-8x 90 BXRE-35E6500-B-8x 80 BXRE-35E6500-C-8x 80 BXRE-35E6500-D-8x 80 BXRE-35G6500-B-8x 90 BXRE-35G6500-C-8x 90 BXRE-35G6500-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 2785 4118 5446 7174 10484 16569 4545 6855 8886 10855 17106 27649 5798 8600 11337 13510 21823 30692 3354 4959 6558 8638 12624 19952 3735 5634 7303 8921 14059 22723 4765 7067 9317 11103 17935 25224 2757 4076 5389 7099 10375 16397 2507 3707 4901 6456 9435 14912 4091 6170 7998 9770 15396 24884 5219 7740 10203 12159 19641 27623 3019 4463 5902 7774 11362 17957 3362 5071 6573 8029 12653 20451 4289 6361 8385 9993 16142 22702 2481 3668 4850 6389 9337 14758 163 159 155 150 141 126 197 191 186 182 170 151 197 191 186 183 170 157 197 191 186 181 170 152 162 157 153 150 140 124 162 157 153 150 140 129 162 157 153 148 140 125 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-40C6501-B-8x 70 BXRE-40C6501-C-8x 70 BXRE-40C6501-D-8x 70 BXRE-40E6500-B-8x 80 BXRE-40E6500-C-8x 80 BXRE-40E6500-D-8x 80 BXRE-40G6500-B-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 4780 7210 9346 11417 17991 29079 6098 9044 11923 14209 22952 32280 3528 5216 6897 9085 13277 20984 4571 6895 8937 10918 17205 27808 5832 8649 11402 13588 21949 30869 3373 4988 6595 8688 12696 20067 3814 5752 7456 9109 14354 23200 4302 6489 8411 10275 16192 26171 5489 8140 10731 12788 20657 29052 3175 4694 6207 8176 11949 18886 4114 6205 8044 9826 15484 25027 5249 7784 10262 12229 19754 27782 3036 4489 5936 7819 11427 18060 3432 5177 6711 8198 12918 20880 207 201 196 192 179 159 207 201 196 192 179 165 207 201 196 190 179 160 198 192 187 183 171 152 198 192 187 184 171 158 198 192 187 182 171 153 165 160 156 153 143 127 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-40G6500-C-8x 90 BXRE-40G6500-D-8x 90 BXRE-50C6501-B-8x 70 BXRE-50C6501-C-8x 70 BXRE-50C6501-D-8x 70 BXRE-50E6501-B-8x 80 BXRE-50E6501-C-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 4865 7216 9512 11336 18312 25753 2814 4161 5502 7248 10592 16741 4806 7249 9397 11479 18090 29238 6132 9094 11988 14287 23078 32456 3547 5244 6935 9135 13349 21099 4624 6973 9039 11042 17401 28126 5898 8748 11532 13743 22200 31222 4379 6494 8561 10203 16480 23178 2533 3745 4952 6523 9533 15067 4326 6524 8457 10331 16281 26314 5519 8184 10789 12858 20770 29211 3192 4720 6241 8221 12014 18989 4161 6276 8136 9938 15661 25313 5309 7873 10379 12369 19980 28099 165 160 156 153 143 132 165 161 156 151 143 128 208 202 197 193 180 160 208 202 197 193 180 166 208 202 197 191 180 161 200 194 189 185 173 154 200 195 189 186 173 160 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-50E6501-D-8x 80 BXRE-50G6501-B-8x 90 BXRE-50G6501-C-8x 90 BXRE-50G6501-D-8x 90 BXRE-57C6501-B-8x 70 BXRE-57C6501-C-8x 70 BXRE-57C6501-D-8x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 3412 5045 6671 8787 12842 20296 3997 6028 7814 9545 15042 24312 5099 7562 9968 11880 19190 26988 2949 4361 5766 7596 11100 17544 4676 7052 9142 11167 17598 28444 5965 8847 11662 13899 22451 31574 3451 5102 6746 8886 12987 20525 3071 4540 6004 7908 11557 18267 3597 5425 7032 8591 13538 21881 4589 6806 8972 10692 17271 24289 2654 3925 5190 6836 9990 15790 4208 6347 8227 10051 15838 25599 5369 7962 10496 12509 20205 28417 3105 4592 6072 7998 11688 18473 200 195 189 184 173 155 173 168 164 160 149 133 173 168 164 161 149 138 173 168 164 159 149 134 202 196 192 188 175 155 202 197 192 188 175 162 202 197 192 186 175 156 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-57E6501-B-8x 80 BXRE-57E6501-C-8x 80 BXRE-57E6501-D-8x 80 BXRE-65C6501-B-8x 70 BXRE-65C6501-C-8x 70 BXRE-65C6501-D-8x 70 BXRE-65E6501-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 475 725 950 1170 1900 3250 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 48.7 49.5 50.2 50.9 53.0 56.4 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 23.1 35.9 47.7 59.5 100.7 183.1 4441 6698 8682 10606 16713 27014 5665 8402 11076 13200 21322 29987 3277 4845 6407 8439 12334 19493 4676 7052 9142 11167 17598 28444 5965 8847 11662 13899 22451 31574 3451 5102 6746 8886 12987 20525 4493 6777 8784 10731 16910 27331 3997 6028 7814 9545 15042 24312 5099 7562 9968 11880 19190 26988 2949 4361 5766 7596 11100 17544 4208 6347 8227 10051 15838 25599 5369 7962 10496 12509 20205 28417 3105 4592 6072 7998 11688 18473 4044 6099 7906 9658 15219 24598 192 187 182 178 166 147 192 187 182 179 166 154 192 187 182 176 166 149 202 196 192 188 175 155 202 197 192 188 175 162 202 197 192 186 175 156 194 189 184 180 168 149 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRE-65E6501-C-8x 80 BXRE-65E6501-D-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 600 900 1200 1440 2400 3500 525 785 1050 1400 2100 3500 49.2 50.0 50.7 51.3 53.5 55.8 32.5 33.0 33.5 34.2 35.4 37.5 29.5 45.0 60.9 73.9 128.5 195.3 17.1 25.9 35.2 47.8 74.3 131.3 5732 8501 11206 13355 21573 30340 3316 4902 6482 8539 12479 19723 5159 7651 10086 12020 19415 27306 2984 4412 5834 7685 11231 17751 194 189 184 181 168 155 194 189 184 178 168 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Electrical Characteristics Table 4: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRE-xxx650x-B-8x BXRE-xxx650x-C-8x BXRE-xxx650x-D-8x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.07 45.1 55.0 -18.19 0.13 50.7 61.8 54.5 -16.35 0.08 45.6 55.6 55.8 60.0 -18.00 0.15 50.2 61.2 31.0 33.5 36.0 -10.81 0.08 30.1 36.7 34.7 37.5 40.3 -12.10 0.14 33.7 41.1 Minimum Typical Maximum 950 46.4 50.2 54.0 -16.19 3250 52.2 56.4 60.6 1200 46.9 50.7 3500 51.6 1050 3500 Notes for Table 4: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application. 16 Eye Safety Table 5: Eye Safety Risk Group (RG) Classifications Part Number BXRE-xxx650x-B-8x BXRE-xxx650x-C-8x BXRE-xxx650x-D-8x CCT Drive Current (mA) 2700K/3000K 4000K2 5000K3 6500K4 1370 RG1 RG1 RG1 RG1 1900 RG1 RG1 RG1 RG2 2525 RG1 RG1 RG2 RG2 3250 RG1 RG2 RG2 RG2 1355 RG1 RG1 RG1 RG1 1880 RG1 RG1 RG1 RG2 2500 RG1 RG1 RG2 RG2 3500 RG1 RG2 RG2 RG2 2055 RG1 RG1 RG1 RG1 2850 RG1 RG1 RG1 RG2 3500 RG1 RG1 RG2 RG2 Notes for Table 5: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 17 Absolute Maximum Ratings Table 6: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRE-xxx650x-B-8x BXRE-xxx650x-C-8x BXRE-xxx650x-D-8x Maximum Drive Current3 3250 mA 3500 mA 3500 mA Maximum Peak Pulsed Drive Current4 3640 mA 3920 mA 3920 mA Maximum Reverse Voltage5 -90V -90V -60V Notes for Table 6: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 18 Performance Curves Figure 2: V22C Drive Current vs. Voltage 57.0 57.0 56.0 56.0 55.0 55.0 54.0 54.0 Voltage (V) Voltage (V) Figure 1: V22B Drive Current vs. Voltage 53.0 52.0 51.0 53.0 52.0 51.0 50.0 50.0 49.0 49.0 48.0 48.0 0 500 1000 1500 2000 2500 3000 0 3500 500 1000 38.0 2500 3000 3500 4000 Relative Luminous Flux (%) 350% 37.0 Voltage (V) 2000 Figure 4: V22B Typical Relative Flux vs. Current Figure 3: V22D Drive Current vs. Voltage 36.0 35.0 34.0 33.0 32.0 0 500 1000 1500 2000 2500 3000 3500 300% 250% 200% 150% 100% 50% 0% 4000 0 500 1000 Drive Current (mA) 1500 2000 2500 3000 3500 Drive Current (mA) Figure 6: V22D Typical Relative Flux vs. Current Figure 5: V22C Typical Relative Flux vs. Current 300% 350% Relative Luminous Flux (%) Relative Luminous Flux (%) 1500 Drive Current (mA) Drive Current (mA) 250% 200% 150% 100% 50% 0% 0 500 1000 1500 2000 2500 Drive Current (mA) 3000 3500 4000 300% 250% 200% 150% 100% 50% 0% 0 500 1000 1500 2000 2500 3000 3500 4000 Drive Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 19 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature 102% 0.0010 100% 0.0000 98% -0.0010 96% -0.0020 ccy shift Relative Luminous Flux Figure 7: Typical DC Flux vs. Case Temperature 94% 92% 25C Pulsed -0.0030 -0.0040 90% -0.0050 88% -0.0060 -0.0070 86% 0 20 40 60 80 100 0 120 20 Figure 9: Typical DC ccx Shift vs. Case Temperature 80 100 120 100 120 Figure 10: Derating Curve 0.0020 4000 25C Pulsed Drive Current (mA) 3500 -0.0020 ccx shift 60 Case Temperature (Tc) Case Temperature (Tc) 0.0000 40 -0.0040 -0.0060 -0.0080 3000 2500 2000 1500 1000 BXRE-xxx650x-B-8x 500 BXRE-xxx650x-C-8x 0 -0.0100 0 20 40 60 80 Case Temperature (Tc) 100 120 0 20 40 60 80 Case Temperature (Tc) 20 Typical Radiation Pattern Figure 11: Typical Spatial Radiation Pattern Note for Figure 11: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 12: Typical Polar Radiation Pattern 21 Typical Color Spectrum Figure 13: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 13: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 22 Mechanical Dimensions Figure 14: Drawing for V22 LED Array Notes for Figure 14: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Solder pad labeled “+” denotes positive contact. 5. Refer to Application Notes AN101 for product handling, mounting and heat sink recommendations. 6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 23 Color Binning Information Figure 15: Graph of Warm and Neutral White Test Bins in xy Color Space Note: Pulsed Test Conditions, Tc = 25°C Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4073, 0.3917) (0.3818, 0.3797) Figure 16: Graph of Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5481K - 5829K) (6270K - 6765K) 83 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 24 Packaging and Labeling Figure 17: Drawing for V22 Packaging Tube 8 Notes for Figure 17: 1. Each tube holds 15 V22 COB arrays. 2. Four tubes are sealed in an anti-static bag. Four bags are placed in a shipping box and shipped. Depending on quantities ordered, a bigger shipping box, containing four boxes may be used to ship products. 3. Each bag and box is to be labeled as shown above. 4. Dimensions for each tube are 30.7 (W) x 9.65(H) x 460(L). Dimensions for the anti-static bag are 120mm (W) x 635mm (L) x 0.1 (T) mm. Dimensions for the shipping box are 58.7 x 13.3 x 7.9 cm. 25 Packaging and Labeling Figure 18: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E6500C 83 2F Internal Bin Code Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 26 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the V Series product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux V Series LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN101 for additional information. CAUTION: RISK OF BURN Do not touch the V Series LED array during operation. Allow the array to cool for a sufficient period of time before handling. The V Series LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 27 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design and Vero are registered trademarks, V Series and Decor Series are trademarks of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 V22 Array Series Product Data Sheet DS416 Rev. A (06/2020) 28
BXRE-40E6500-D-83 价格&库存

很抱歉,暂时无法提供与“BXRE-40E6500-D-83”相匹配的价格&库存,您可以联系我们找货

免费人工找货