BXEN-57S-11M-3C-00-0-3 数据手册
Bridgelux SMD 2835 0.5W 3V Thrive™
®
Product Data Sheet DS312
Bridgelux SMD 2835 1W 9V Thrive Product Data Sheet DS310 Rev. A (08/2019)
| | |
BXEN-27S 30S 40S 50S
1
SMD 2835 Thrive
Introduction
Bridgelux Thrive™ combines unique chip, phosphor and packaging technology to closely match the spectra of natural
light over the visible wavelength range. Thrive can be used in constant color point luminaires to bring full spectrum
natural light indoors or in tunable white luminaires to incorporate circadian elements that may impact human well-being.
The high fidelity spectral output of Thrive creates stunning environments with excellent color rendering and outstanding
TM30 metrics. Thrive is available in both SMD components and LED arrays to enable a broad range of lighting
applications including retail, hospitality, office, education, architectural, museums, healthcare and residential lighting.
Features
Benefits
• Engineered spectra to closely match natural light
• Full consistent spectrum with fewer spectral spikes
• CRI > 95, R1-R15 >90, high Rf and Rg values
• Natural and vivid color rendering
• High efficiency full spectrum solution
• Greater energy savings, lower utility costs
• No violet chip augmentation
• Economical, high efficiency solution
• Hot color targeted
• Uniform and consistent white light under application
conditions
• Industry standard 2835 footprint
• Broad product platform availability (SMDs and COBs)
• Ease of design and rapid go-to-market
• Enables greater design flexibility and platform color
consistency
2
Contents
Product Feature Map
2
Product Nomenclature
2
Product Test Conditions
2
Product Selection Guide
3
Spectrum Characteristics
4
Electrical Characteristics
7
Absolute Maximum Ratings
8
Product Bin Definitions
9
Performance Curves
12
Typical Radiation Pattern
13
Mechanical Dimensions
14
Reliability
15
Reflow Characteristics
16
Packaging
17
Design Resources
19
Precautions
19
Disclaimers
19
About Bridgelux
20
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
1
Product Feature Map
Bridgelux SMD LED products come in industry standard package sizes and follow ANSI binning standards. These LEDs
are optimized for cost and performance, helping to ensure highly competitive system lumen per dollar performance while
addressing the stringent efficacy and reliability standards required for modern lighting applications.
Cathode Mark
Yellow phosphor Light
Emitting Surface (LES)
Product Nomenclature
The part number designation for Bridgelux SMD 2835 is explained as follows:
1 2 3 4
5 6 7
8
9
10
11
12
13 14
15
16
BXEN – 27 S – 1 1 M – 3 C –00 – 0 – 0
Color Bin Options
Product Family
Forward Voltage Bins
Nominal CCT
27 = 2,700K
30 = 3,000K
40 = 4,000K
50 = 5,000K
Flux Bins
Product Version
Minimum CRI
S = Thrive
Typical Forward Voltage
Mid Power
Die count in series
Die count in parallel
Product Test Conditions
Bridgelux SMD 2835 LEDs are tested and binned with a 10ms pulse of 150mA at Tj (junction temperature)=Tsp (solder point temperature)
=25°C. Forward voltage and luminous flux are binned at a Tj=Tsp=25°C, while color is hot targeted at a Tsp of 85°C.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data at 150mA (Tj=Tsp=25°C)
Typical Pulsed Flux (lm)4, 5
CRI3, 5
(Typical)
Min
Typical
Max
Min
2700
97
150
2.90
3.10
3.30
45.0
3000
97
150
2.90
3.10
3.30
45.0
4000
97
150
2.90
3.10
3.30
50.0
5000
97
150
2.90
3.10
3.30
55.0
BXEN-27S-11M-3C-00-0-0
BXEN-30S-11M-3C-00-0-0
BXEN-40S-11M-3C-00-0-0
BXEN-50S-11M-3C-00-0-0
Part Number1,6
Forward Voltage4, 5
(V)
Nominal
Drive
Current
(mA)
Nominal
CCT2
(K)
Max
Typical
Power
(W)
Typical
Efficacy
(lm/W)
51.0
55.0
0.5
110
55.0
60.0
0.5
118
56.0
60.0
0.5
120
59.0
65.0
0.5
127
Typical
Table 2: Selection Guide, Pulsed Test Performance at 150mA (Tsp = 85°C)7,8
Nominal
CCT2
(K)
CRI3, 5
(Typical)
Nominal
Drive
Current
(mA)
Min
Typical
Max
Min
Typical
BXEN-27S-11M-3C-00-0-0
2700
97
150
2.84
3.04
3.24
39.2
BXEN-30S-11M-3C-00-0-0
3000
97
150
2.84
3.04
3.24
39.2
BXEN-40S-11M-3C-00-0-0
4000
97
150
2.84
3.04
3.24
43.6
BXEN-50S-11M-3C-00-0-0
5000
97
150
2.84
3.04
3.24
47.9
Part Number1,6
Forward Voltage5
(V)
Typical Pulsed Flux
(lm)5
Max
Typical
Power
(W)
Typical
Efficacy
(lm/W)
44.5
47.9
0.5
98
47.9
52.3
0.5
105
48.8
52.3
0.5
107
51.4
56.6
0.5
113
Notes for Tables 1 & 2:
1. The last 6 characters (including hyphens ‘-’) refer to flux bins, forward voltage bins, and color bin options, respectively. “00-0-0” denotes the full
distribution of flux, forward voltage, and 6 SDCM color.
Example: BXEN-27S-11M-3C-00-0-0 refers to the full distribution of flux, forward voltage, and color within a 2700K 6-step ANSI standard
chromaticity region with a minimum of 97 CRI, 1x1 die configuration, mid power, 3.1V typical forward voltage.
2. Product CCT is hot targeted at Tsp = 85°C. Nominal CCT as defined by ANSI C78.377-2011.
3. Listed CRIs are typical values and include test tolerance.
4. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tj=Tsp=25°C.
5. Bridgelux maintains a ±7.5% tolerance on luminous flux measurements, ±0.1V tolerance on forward voltage measurements, and ±2 tolerance on
CRI measurements for the SMD 2835.
6. Refer to Table 6 and Table 7 for Bridgelux SMD 2835 Luminous Flux Binning and Forward Voltage Binning information.
7. Typical pulsed test performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under pulsed current with LED emitter mounted onto a heat sink with thermal interface
material and the solder point temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
3
Spectrum Characteristics
Table 3: Typical Color Rendering Index and TM-30 Values, 150mA, Tsp=85°C 1
Nominal
CCT1
Rf
Rg
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
2700K
95
101
98
99
94
95
98
98
98
98
93
96
92
94
98
96
99
3000K
97
101
99
98
96
96
99
99
98
97
93
98
94
98
99
97
99
4000K
96
101
99
98
93
96
99
96
96
97
98
93
96
91
99
96
99
5000K
95
100
98
98
95
97
98
96
97
98
95
94
97
91
98
97
94
Note for Table 3:
1. Bridgelux maintains a tolerance of ± 3 on Color Rendering Index R1-R15 measurements and TM-30 measurements.
2. Rn values are a reference at nominal drive current. Rn values will have deviations at alternate drive currents
Figure 1: 2700K Thrive TM-30 Graphs
Figure 2: 3000K Thrive TM-30 Graphs
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
4
Spectrum Characteristics
Figure 3: 4000K Thrive TM-30 Graphs
Figure 4: 5000K Thrive TM-30 Graphs
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
5
Spectrum Characteristics
Figure 5: Typical Color Spectrum
100%
27S
30S
40S
50S
Relative Radiant Power
90%
80%
70%
60%
50%
40%
30%
20%
10%
0%
380
430
480
530
580
630
680
730
780
Wavelength (nm)
Note for Figure 5:
1. Color spectra measured at nominal current for Tsp = 85°C.
Spectral Matching to Natural Light
The lighting market is in the early stages of adoption of human-centric lighting (HCL). HCL encompasses the effects of lighting on the physical and emotional
health and well-being of people. Throughout evolution, the human visual system has evolved under the natural light of sun and fire. These light sources have
standardized industry spectral power definitions that describe the state of natural light. However, conventional metrics such as CCT, CRI, and TM-30 fail to
adequately quantify the naturalness, or closeness of these light sources to the standardized natural spectra. Due to a lack of an industry standard metric to
quantitatively measure the naturalness of a light source, Bridgelux has pioneered a new metric that takes the guesswork out of comparing LED light sources
to natural light.
Average Spectral Difference, or ASD, is calculated by measuring the absolute difference between two spectra at discrete wavelengths. These values are averaged across a wavelength range derived from the photopic response curve, or V(λ); a luminous efficiency function describing the average spectral sensitivity
of human perception of brightness. The range of 425nm to 690nm was selected to remove the tails of the V(λ) gaussian distribution below 1% of the peak value
at 555nm, covering 99.9% of the area under the photopic response curve. Natural light is defined following the approach of IES TM-30; black body curves for
light sources of ≤4000K and the CIE standard illuminant D for light sources of ≥ 5000K.
Natural light has an ASD of 0%; lower ASD values indicate a closer match to natural light. Thrive is engineered to provide the closest match to natural light
available using proprietary chip, phosphor and packaging technology, resulting in an ASD between 8% to 10% for all CCTs. By comparison, standard 80, 90,
and 98 CRI light sources have ASD values that are 100% to 300% larger than Thrive. To learn more about the ASD metric, please contact your Bridgelux sales
representative. Bridgelux will publish a white paper to further educate the market about the benefits of the ASD metric in Q2 2020.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
6
Electrical Characteristics
Table 4: Electrical Characteristics
Forward Voltage
(V) 2,3
Part Number 1
BXEN-XXX-11M-3C-00-0-0
Drive Current
(mA)
150
Minimum
Typical
Maximum
2.9
3.1
3.3
Typical
Temperature
Coefficient
of Forward
Voltage
∆Vf/∆T
(mV/ºC)
Typical
Thermal
Resistance Junction
to Solder Point4
R j-sp (ºC/W)
-1.04
31
Notes for Table 4:
1. The last 6 characters (including hyphens ‘-’) refer to flux bins, forward voltage bins, and color bin options, respectively. “00-0-00” denotes the full
distribution of flux, forward voltage, and 6 SDCM color.
Example: BXEN-27S-11M-3C-00-0-0 refers to the full distribution of flux, forward voltage, and color within a 2700K 6-step ANSI standard
chromaticity region with a minimum of 97 CRI, 1x1 die configuration, mid power, 3.1V typical forward voltage.
2. Bridgelux maintains a tolerance of ± 0.1V on forward voltage measurements. Voltage minimum and maximum values at the nominal drive current
are guaranteed by 100% test.
3. Products tested under pulsed condition (10ms pulse width) at nominal drive current where Tsp = 25°C.
4. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
7
Absolute Maximum Ratings
Table 5: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
125°C
Storage Temperature
-40°C to +105°C
Operating Solder Point Temperature (TSp)
-40°C to +105°C
Soldering Temperature
260°C or lower for a maximum of 10 seconds
Maximum Drive Current
150mA
Maximum Peak Pulsed Forward Current1
300mA
Maximum Reverse Voltage2
-
Moisture Sensitivity Rating
MSL 3
Electrostatic Discharge
2kV HBM. JEDEC-JS-001-HBM and JEDEC-JS-001-2012
Notes for Table 5:
1. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 10 ms when operating LED SMD at maximum peak pulsed current specified. Maximum peak pulsed current indicate values where LED SMD can be driven without catastrophic failures.
2. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. no rating is provided.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
8
Product Bin Definitions
Table 6 lists the standard photometric luminous flux bins for Bridgelux SMD 2835 LEDs. Although several bins are listed,
product availability in a particular bin varies by production run and by product performance. Not all bins are available in
all CCTs.
Table 6: Luminous Flux Bin Definitions at 150mA, Tsp=25°C
Bin Code
Minimum
Maximum
29
45
≦50
2A
50
55
2B
55
60
2C
60
65
Unit
Condition
lm
IF=150mA
Unit
Condition
V
IF=150mA
Note for Table 6:
1. Bridgelux maintains a tolerance of ± 7.5% on luminous flux measurements
Table 7: Forward Voltage Bin Definition at 150mA, Tsp=25°C
Bin Code
Minimum
Maximum
A
2.8
2.9
B
2.9
3.0
C
3.0
3.1
D
3.1
3.2
E
3.2
3.3
Note for Table 7:
1. Bridgelux maintains a tolerance of ± 0.1V on forward voltage measurements.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
9
Product Bin Definitions
Table 8: McAdam Ellipse Color Bin Definitions
CCT
2700K
3000K
4000K
5000K
Color Space
Center Point
Major Axis
Minor Axis
Ellipse
Rotation Angle
Color Bin
X
Y
2 SDCM
0.4578
0.4101
0.0054
0.0028
53.70
2
3 SDCM
0.4578
0.4101
0.0081
0.0042
53.70
2/3
6 SDCM
0.4578
0.4101
0.0162
0.0084
53.70
2/3/A/B/C/D/E/F
2 SDCM
0.4338
0.4030
0.00556
0.00272
53.22
2
3 SDCM
0.4338
0.4030
0.00834
0.00408
53.22
2/3
6 SDCM
0.4338
0.4030
0.01668
0.00816
53.22
2/3/A/B/C/D/E/F
2 SDCM
0.3818
0.3797
0.00626
0.00268
53.72
2
3 SDCM
0.3818
0.3797
0.00939
0.00402
53.72
2/3
6 SDCM
0.3818
0.3797
0.01878
0.00804
53.72
2/3/A/B/C/D/E/F
3 SDCM
0.3447
0.3553
0.00822
0.00354
59.62
3
6 SDCM
0.3447
0.3553
0.01644
0.00708
59.62
3/A/B/C/D/E/F
Notes for Table 8:
1. Color binning at Tsp=85°C unless otherwise specified
2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
10
Product Bin Definitions
Figure 6: C.I.E. 1931 Chromaticity Diagram (Color Targeted at Tsp=85°C)
2700K
0.4150
0.4250
0.4200
C
0.4050
3
0.4000
2
0.4000
0.3900
0.4450
0.4500
0.4550
x
0.4600
0.4650
0.4700
0.4750
0.3850
0.4200
4000K
0.4000
0.4250
0.4300
0.4350
x
0.4400
0.4450
0.4500
5000K
0.3750
0.3700
0.3950
B
3
0.3700
y
F
C
0.3750
F
0.3550
C
3
0.3500
2
E
E
0.3450
D
D
0.3400
0.3650
0.3700
B
0.3600
0.3850
0.3800
A
0.3650
A
0.3900
y
E
D
D
0.3950
0.3600
0.3650
2
3
0.3950
E
F
C
y
y
0.4050
F
0.4100
A
B
0.4100
A
B
0.4150
0.3900
0.4400
3000K
0.4200
0.4300
0.3750
0.3800
x
0.3850
0.3900
0.3950
0.3350
0.3300
0.3350
0.3400
0.3450
0.3500
0.3550
0.3600
x
Kitting bins matching
BIN#1
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
BIN#2
2
2
3
3
A
B
C
D
E
F
11
Performance Curves
Figure 8: Typical Relative Luminous Flux vs. Drive Current
Figure 7: Drive Current vs. Voltage (Tsp=25°C)
(Tsp=25°C)1
100%
120
Relative Luminous Flux
Forward Current (mA)
150
90
60
30
75%
50%
25%
0%
0
0
2.6
2.7
2.8
2.9
Forward Voltage (V)
3.0
60
90
120
150
Forward Current (mA)
Figure 10: Typical ccx Shift vs. Solder Point Temperature2,3,4,5
100%
0.000
95%
-0.001
ccx Shift
Relative Luminous Flux
Figure 9: Typical Relative Flux vs. Solder Point
Temperature2,3,4,5
90%
Warm White
Neutral White
Cool White
85%
30
3.1
-0.002
Warm White
-0.003
Neutral White
Cool White
-0.004
80%
0
25
50
75
100
125
0
25
50
75
100
125
Solder Point Temperature (℃)
Solder Point Temperature (℃)
Figure 11: Typical ccy Shift vs. Solder Point Temperature2,3,4,5
Note for Figures 7-11:
0.000
1. Bridgelux does not recommend driving mid power LEDs at low currents.
Doing so may produce unpredictable results. Pulse width modulation
(PWM) is recommended for dimming effects.
ccy Shift
-0.002
2. Characteristics shown for warm white based on 2700K.
3. Characteristics shown for neutral white based on 4000K.
4. Characteristics shown for cool white based on 5000K.
-0.004
5. For other color SKUs, the shift in color will vary. Please contact your
Bridgelux Sales Representative for more information .
Warm White
-0.006
Neutral White
Cool White
-0.008
0
25
50
75
100
125
Solder Point Temperature(℃)
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
12
Typical Radiation Pattern
Figure 12: Typical Spatial Radiation Pattern at 150mA, Tsp=25°C
Relative Intensity
100%
80%
60%
40%
20%
0%
-90
-75
-60
-45
-30
-15
0
15
30
45
60
75
90
Angular Displacement (⁰)
Notes for Figure 12:
1. Typical viewing angle is 116⁰.
2. The viewing angle is defined as the off axis angle from the centerline where luminous intensity (Iv) is ½ of the peak value.
Figure 13: Typical Polar Radiation Pattern at 150mA, Tsp=25°C
0°
Radiation Angle
-30°
-90°
100
30°
-60°
60°
90°
50
0
50
100
Relative Luminosity
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
13
Mechanical Dimensions
Figure 14: Drawing for SMD 2835
Notes for Figure 14:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ± 0.10mm.
Bridgelux SMD 2835 0.5W 3V Thrive Product Data Sheet DS312 Rev. A (04/2020)
14
Reliability
Table 9: Reliability Test Items and Conditions
No .
Items
R而非人eference
Standard
Test Conditions
Drive
Current
Test
Duration
Units
Failed/Tested
1
Moisture/Reflow Sensitivity
J-STD-020E
Tsld = 260°C, 10sec,
Precondition: 60°C, 60%RH, 168hr
-
3 reflows
0/22
2
Low Temperature Storage
JESD22-A119
Ta=-40°C
-
1000 hours
0/22
3
High Temperature Storage
JESD22-A103D
Ta= 105°C
-
1000 hours
0/22
4
Low Temperature Operating Life
JESD22-A108D
Ta=-40°C
150mA
1000 hours
0/22
5
Temperature Humidity Operating
Life
JESD22-A101C
Tsp=85°C℃, RH=85%
150mA
1000 hours
0/22
6
High Temperature Operating Life
JESD22-A108D
Tsp=105°C
150mA
1000 hours
0/22
7
Power switching
IEC62717:2014
Tsp= 105°C
30 sec on, 30 sec off
150mA
30000 cycles
0/22
8
Thermal Shock
JESD22-A106B
Ta=-40°C ~100°C;
Dwell : 15min; Transfer: 10sec
-
200 cycles
0/22
9
Temperature Cycle
JESD22-A104E
Ta=-40°C ~100°C;
Dwell at extreme temperature:
15min; Ramp rate < 105°C/min
-
200 cycles
0/22
10
Electrostatic Discharge
JS-001-2012
HBM, 2KV, 1.5kΩ, 100pF,
Alternately positive or negative
-
-
0/22
Passing Criteria
Item
Symbol
Test Condition
Passing Criteria
Forward Voltage
Vf
150mA
ΔVf