0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-40E2000-D-83

BXRC-40E2000-D-83

  • 厂商:

    BRIDGELUX

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
BXRC-40E2000-D-83 数据手册
Bridgelux Gen 8 Vero 13 Array ® ® Product Data Sheet DS421 1 Vero® Series Introduction The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Features Benefits • On board connector port • Solder free installation and field upgradability • Top side part number markings • Improved inventory management and quality control • Efficacy of 178 lm/W typical, 3000K 80 CRI • Enables high efficiency lighting systems and lower operating costs • Reliable operation at up to 3x nominal current, 30% increase in maximum lumens per LES size • Wide selection of CCT options (2700K-6500K) with minimum 70, 80 and 90 CRI options • Uniform high-quality illumination • 2 and 3 SDCM binning options (2700K – 4000K) • Forward voltage bin codes (backside marking) • Thermally isolated solder pads • 10-Year warranty • Supports the trend toward luminaire miniaturization and delivers enhanced optical control • Design flexibility for a broad range of lighting applications • Clean white light without pixelation • Uniform consistent white light • Design flexibility for multi-source applications • Enhanced ease of use and installation • Design with confidence Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 7 Electrical Characteristics 16 Eye Safety 17 Absolute Maximum Ratings 18 Performance Curves 19 Typical Radiation Pattern 21 Typical Color Spectrum 22 Mechanical Dimensions 23 Color Binning Information 24 Packaging and Labeling 25 Design Resources 27 Precautions 27 Disclaimers 27 About Bridgelux 28 1 Product Feature Map Vero 13 is the second smallest form factor in the Vero family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Optics location/mounting features Correlates to the true case temperature on the back surface of the LED array Mounting holes Radial die configuration improves lumen density and beam control Zhaga Book 3 compatible mounting locations Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 200 0 – C – 8 3 CCT Bin Options Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 8 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 200x = 2000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-8x 2700 80 350 1963 1767 33.4 11.7 168 BXRC-27E2000-C-8x 2700 80 500 2805 2524 33.4 16.7 168 BXRC-27E2000-D-8x 2700 80 400 2068 1861 30.9 12.4 167 139 BXRC-27G2000-B-8x 2700 90 350 1620 1458 33.4 11.7 BXRC-27G2000-C-8x 2700 90 500 2314 2082 33.4 16.7 139 BXRC-27G2000-D-8x 2700 90 400 1706 1535 30.9 12.4 138 BXRC-27G20H0-B-8x 2700 90 350 1690 1521 33.4 11.7 145 BXRC-27G20H0-C-8x 2700 90 500 2414 2172 33.4 16.7 145 BXRC-27G20H0-D-8x 2700 90 400 1780 1602 30.9 12.4 144 187 BXRC-30C2001-B-8x 3000 70 350 2184 1966 33.4 11.7 BXRC-30C2001-C-8x 3000 70 500 3120 2808 33.4 16.7 187 BXRC-30C2001-D-8x 3000 70 400 2300 2070 30.9 12.4 186 BXRC-30E2000-B-8x 3000 80 350 2086 1877 33.4 11.7 178 BXRC-30E2000-C-8x 3000 80 500 2980 2682 33.4 16.7 178 BXRC-30E2000-D-8x 3000 80 400 2197 1977 30.9 12.4 178 BXRC-30G2000-B-8x 3000 90 350 1693 1524 33.4 11.7 145 BXRC-30G2000-C-8x 3000 90 500 2419 2177 33.4 16.7 145 BXRC-30G2000-D-8x 3000 90 400 1783 1605 30.9 12.4 144 BXRC-30G20H0-B-8x 3000 90 350 1773 1596 33.4 11.7 152 BXRC-30G20H0-C-8x 3000 90 500 2533 2280 33.4 16.7 152 BXRC-30G20H0-D-8x 3000 90 400 1867 1681 30.9 12.4 151 BXRC-35E2000-B-8x 3500 80 350 2135 1922 33.4 11.7 183 BXRC-35E2000-C-8x 3500 80 500 3050 2745 33.4 16.7 183 BXRC-35E2000-D-8x 3500 80 400 2249 2024 30.9 12.4 182 BXRC-35G2000-B-8x 3500 90 350 1755 1579 33.4 11.7 150 BXRC-35G2000-C-8x 3500 90 500 2507 2256 33.4 16.7 150 BXRC-35G2000-D-8x 3500 90 400 1848 1663 30.9 12.4 150 BXRC-40C2001-B-8x 4000 70 350 2246 2021 33.4 11.7 192 BXRC-40C2001-C-8x 4000 70 500 3208 2887 33.4 16.7 192 BXRC-40C2001-D-8x 4000 70 400 2365 2129 30.9 12.4 191 BXRC-40E2000-B-8x 4000 80 350 2147 1933 33.4 11.7 184 BXRC-40E2000-C-8x 4000 80 500 3068 2761 33.4 16.7 184 BXRC-40E2000-D-8x 4000 80 400 2262 2035 30.9 12.4 183 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-40G2000-B-8x 4000 90 350 1792 1612 33.4 11.7 153 153 BXRC-40G2000-C-8x 4000 90 500 2559 2303 33.4 16.7 BXRC-40G2000-D-8x 4000 90 400 1887 1698 30.9 12.4 153 BXRC-50C2001-B-8x 5000 70 350 2258 2032 33.4 11.7 193 193 BXRC-50C2001-C-8x 5000 70 500 3225 2903 33.4 16.7 BXRC-50C2001-D-8x 5000 70 400 2378 2140 30.9 12.4 192 BXRC-50E2001-B-8x 5000 80 350 2172 1955 33.4 11.7 186 BXRC-50E2001-C-8x 5000 80 500 3103 2792 33.4 16.7 186 BXRC-50E2001-D-8x 5000 80 400 2287 2059 30.9 12.4 185 BXRC-50G2001-B-8x 5000 90 350 1877 1690 33.4 11.7 161 BXRC-50G2001-C-8x 5000 90 500 2682 2414 33.4 16.7 161 BXRC-50G2001-D-8x 5000 90 400 1977 1780 30.9 12.4 160 BXRC-57C2001-B-8x 5700 70 350 2196 1977 33.4 11.7 188 BXRC-57C2001-C-8x 5700 70 500 3138 2824 33.4 16.7 188 BXRC-57C2001-D-8x 5700 70 400 2313 2082 30.9 12.4 187 BXRC-57E2001-B-8x 5700 80 350 2086 1877 33.4 11.7 178 BXRC-57E2001-C-8x 5700 80 500 2980 2682 33.4 16.7 178 BXRC-57E2001-D-8x 5700 80 400 2197 1977 30.9 12.4 178 BXRC-65C2001-B-8x 6500 70 350 2196 1977 33.4 11.7 188 BXRC-65C2001-C-8x 6500 70 500 3138 2824 33.4 16.7 188 BXRC-65C2001-D-8x 6500 70 400 2313 2082 30.9 12.4 187 BXRC-65E2001-B-8x 6500 80 350 2111 1899 33.4 11.7 181 BXRC-65E2001-C-8x 6500 80 500 3015 2714 33.4 16.7 181 BXRC-65E2001-D-8x 6500 80 400 2223 2001 30.9 12.4 180 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 4 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-8x 2700 80 350 1767 1590 32.7 11.4 154 BXRC-27E2000-C-8x 2700 80 500 2524 2272 32.7 16.3 154 BXRC-27E2000-D-8x 2700 80 400 1861 1675 30.2 12.1 154 BXRC-27G2000-B-8x 2700 90 350 1458 1312 32.7 11.4 127 BXRC-27G2000-C-8x 2700 90 500 2082 1874 32.7 16.3 127 BXRC-27G2000-D-8x 2700 90 400 1535 1382 30.2 12.1 127 BXRC-27G20H0-B-8x 2700 90 350 1521 1369 32.7 11.4 133 BXRC-27G20H0-C-8x 2700 90 500 2172 1955 32.7 16.3 133 BXRC-27G20H0-D-8x 2700 90 400 1602 1441 30.2 12.1 132 BXRC-30C2001-B-8x 3000 70 350 1966 1769 32.7 11.4 172 BXRC-30C2001-C-8x 3000 70 500 2808 2527 32.7 16.3 172 BXRC-30C2001-D-8x 3000 70 400 2070 1863 30.2 12.1 171 BXRC-30E2000-B-8x 3000 80 350 1877 1690 32.7 11.4 164 BXRC-30E2000-C-8x 3000 80 500 2682 2414 32.7 16.3 164 BXRC-30E2000-D-8x 3000 80 400 1977 1780 30.2 12.1 164 BXRC-30G2000-B-8x 3000 90 350 1524 1372 32.7 11.4 133 133 BXRC-30G2000-C-8x 3000 90 500 2177 1959 32.7 16.3 BXRC-30G2000-D-8x 3000 90 400 1605 1445 30.2 12.1 133 BXRC-30G20H0-B-8x 3000 90 350 1596 1436 32.7 11.4 140 140 BXRC-30G20H0-C-8x 3000 90 500 2280 2052 32.7 16.3 BXRC-30G20H0-D-8x 3000 90 400 1681 1513 30.2 12.1 139 BXRC-35E2000-B-8x 3500 80 350 1922 1729 32.7 11.4 168 BXRC-35E2000-C-8x 3500 80 500 2745 2471 32.7 16.3 168 BXRC-35E2000-D-8x 3500 80 400 2024 1821 30.2 12.1 167 BXRC-35G2000-B-8x 3500 90 350 1579 1421 32.7 11.4 138 BXRC-35G2000-C-8x 3500 90 500 2256 2030 32.7 16.3 138 BXRC-35G2000-D-8x 3500 90 400 1663 1497 30.2 12.1 138 BXRC-40C2001-B-8x 4000 70 350 2021 1819 32.7 11.4 177 BXRC-40C2001-C-8x 4000 70 500 2887 2598 32.7 16.3 177 BXRC-40C2001-D-8x 4000 70 400 2129 1916 30.2 12.1 176 BXRC-40E2000-B-8x 4000 80 350 1933 1739 32.7 11.4 169 BXRC-40E2000-C-8x 4000 80 500 2761 2485 32.7 16.3 169 BXRC-40E2000-D-8x 4000 80 400 2035 1832 30.2 12.1 168 141 BXRC-40G2000-B-8x 4000 90 350 1612 1451 32.7 11.4 BXRC-40G2000-C-8x 4000 90 500 2303 2073 32.7 16.3 141 BXRC-40G2000-D-8x 4000 90 400 1698 1528 30.2 12.1 140 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50C2001-B-8x 5000 70 350 2032 1829 32.7 11.4 178 BXRC-50C2001-C-8x 5000 70 500 2903 2613 32.7 16.3 178 BXRC-50C2001-D-8x 5000 70 400 2140 1926 30.2 12.1 177 BXRC-50E2001-B-8x 5000 80 350 1955 1759 32.7 11.4 171 BXRC-50E2001-C-8x 5000 80 500 2792 2513 32.7 16.3 171 BXRC-50E2001-D-8x 5000 80 400 2059 1853 30.2 12.1 170 BXRC-50G2001-B-8x 5000 90 350 1690 1521 32.7 11.4 148 BXRC-50G2001-C-8x 5000 90 500 2414 2172 32.7 16.3 148 BXRC-50G2001-D-8x 5000 90 400 1780 1602 30.2 12.1 147 BXRC-57C2001-B-8x 5700 70 350 1977 1779 32.7 11.4 173 BXRC-57C2001-C-8x 5700 70 500 2824 2542 32.7 16.3 173 BXRC-57C2001-D-8x 5700 70 400 2082 1874 30.2 12.1 172 BXRC-57E2001-B-8x 5700 80 350 1877 1690 32.7 11.4 164 BXRC-57E2001-C-8x 5700 80 500 2682 2414 32.7 16.3 164 BXRC-57E2001-D-8x 5700 80 400 1977 1780 30.2 12.1 164 BXRC-65C2001-B-8x 6500 70 350 1977 1779 32.7 11.4 173 BXRC-65C2001-C-8x 6500 70 500 2824 2542 32.7 16.3 173 BXRC-65C2001-D-8x 6500 70 400 2082 1874 30.2 12.1 172 BXRC-65E2001-B-8x 6500 80 350 1899 1710 32.7 11.4 166 BXRC-65E2001-C-8x 6500 80 500 2714 2442 32.7 16.3 166 BXRC-65E2001-D-8x 6500 80 400 2001 1801 30.2 12.1 165 Notes for Table 2: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3. Table 3: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-27E2000-B-8x 80 BXRC-27E2000-C-8x 80 BXRC-27E2000-D-8x 80 BXRC-27G2000-B-8x 90 BXRC-27G2000-C-8x 90 BXRC-27G2000-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 1019 1476 1963 2478 3750 6363 1455 2128 2805 3473 5357 8928 1073 1569 2068 2542 3950 5947 840 1218 1620 2044 3094 5250 1200 1756 2314 2866 4420 7366 885 1295 1706 2097 3258 4906 917 1329 1767 2230 3375 5727 1310 1916 2524 3126 4821 8035 965 1412 1861 2287 3555 5352 756 1096 1458 1840 2784 4725 1080 1580 2082 2579 3978 6629 797 1165 1535 1887 2933 4416 179 173 168 162 152 135 179 172 168 163 152 136 179 172 168 163 152 139 148 142 139 134 126 112 148 142 138 134 126 112 148 142 138 134 125 115 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 7 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G20H0-B-8x 90 BXRC-27G20H0-C-8x 90 BXRC-27G20H0-D-8x 90 BXRC-30C2001-B-8x 70 BXRC-30C2001-C-8x 70 BXRC-30C2001-D-8x 70 BXRC-30E2000-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 877 1271 1690 2133 3227 5476 1252 1832 2414 2989 4610 7684 923 1350 1780 2187 3399 5118 1133 1643 2184 2757 4172 7079 1619 2368 3120 3864 5960 9933 1193 1746 2300 2828 4394 6616 1082 1569 2086 2633 3984 6761 789 1144 1521 1920 2905 4929 1127 1649 2172 2690 4149 6916 831 1215 1602 1969 3059 4606 1020 1478 1966 2481 3755 6371 1457 2131 2808 3478 5364 8939 1074 1571 2070 2545 3954 5954 974 1412 1877 2370 3586 6085 154 149 145 140 131 117 154 148 144 140 131 117 154 148 144 140 131 120 200 192 187 181 169 151 199 192 187 181 169 151 199 191 186 181 169 155 191 183 178 172 162 144 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E2000-C-8x 80 BXRC-30E2000-D-8x 80 BXRC-30G2000-B-8x 90 BXRC-30G2000-C-8x 90 BXRC-30G2000-D-8x 90 BXRC-30G20H0-B-8x 90 BXRC-30G20H0-C-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 1546 2261 2980 3691 5692 9486 1140 1667 2197 2700 4196 6319 878 1273 1693 2137 3234 5488 1255 1836 2419 2996 4621 7701 925 1353 1783 2192 3406 5129 920 1333 1773 2238 3387 5747 1314 1922 2533 3137 4838 8063 1391 2035 2682 3321 5123 8538 1026 1500 1977 2430 3777 5687 791 1146 1524 1924 2911 4939 1129 1652 2177 2696 4158 6931 833 1218 1605 1973 3066 4616 828 1200 1596 2014 3048 5172 1183 1730 2280 2823 4354 7257 190 183 178 173 162 144 190 183 178 173 161 148 155 149 145 140 131 117 155 149 145 140 131 117 154 148 145 140 131 120 162 156 152 147 138 122 162 156 152 147 137 123 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 9 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G20H0-D-8x 90 BXRC-35E2000-B-8x 80 BXRC-35E2000-C-8x 80 BXRC-35E2000-D-8x 80 BXRC-35G2000-B-8x 90 BXRC-35G2000-C-8x 90 BXRC-35G2000-D-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 969 1417 1867 2295 3567 5371 1108 1606 2135 2695 4078 6920 1582 2315 3050 3777 5826 9710 1167 1706 2249 2764 4295 6467 910 1320 1755 2215 3352 5687 1300 1902 2507 3104 4788 7980 959 1402 1848 2272 3530 5315 872 1275 1681 2066 3210 4834 997 1445 1922 2426 3670 6228 1424 2083 2745 3400 5243 8739 1050 1536 2024 2488 3866 5821 819 1188 1579 1993 3016 5118 1170 1712 2256 2794 4309 7182 863 1262 1663 2044 3177 4784 162 155 151 147 137 126 195 188 183 177 166 147 195 187 182 177 165 148 195 187 182 177 165 152 160 154 150 145 136 121 160 154 150 145 136 121 160 154 150 145 136 125 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C2001-B-8x 70 BXRC-40C2001-C-8x 70 BXRC-40C2001-D-8x 70 BXRC-40E2000-B-8x 80 BXRC-40E2000-C-8x 80 BXRC-40E2000-D-8x 80 BXRC-40G2000-B-8x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 1165 1689 2246 2834 4289 7278 1664 2434 3208 3973 6127 10212 1227 1795 2365 2907 4517 6802 1114 1615 2147 2711 4102 6960 1591 2328 3068 3799 5859 9765 1173 1716 2262 2780 4320 6505 929 1347 1792 2261 3422 5806 1048 1520 2021 2551 3860 6550 1498 2191 2887 3575 5514 9191 1104 1615 2129 2616 4066 6122 1003 1453 1933 2439 3691 6264 1432 2095 2761 3419 5273 8789 1056 1545 2035 2502 3888 5854 836 1213 1612 2035 3080 5226 205 197 192 186 174 155 205 197 192 186 174 155 205 197 192 186 174 159 196 189 184 178 167 148 196 188 184 178 166 149 196 188 183 178 166 152 164 157 153 148 139 124 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40G2000-C-8x 90 BXRC-40G2000-D-8x 90 BXRC-50C2001-B-8x 70 BXRC-50C2001-C-8x 70 BXRC-50C2001-D-8x 70 BXRC-50E2001-B-8x 80 BXRC-50E2001-C-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 1328 1942 2559 3170 4888 8147 979 1432 1887 2319 3604 5427 1171 1698 2258 2850 4312 7318 1673 2448 3225 3994 6161 10268 1234 1805 2378 2923 4542 6839 1127 1633 2172 2741 4148 7039 1610 2355 3103 3842 5926 9877 1195 1748 2303 2853 4400 7332 881 1289 1698 2087 3244 4884 1054 1528 2032 2565 3881 6586 1506 2203 2903 3595 5545 9241 1110 1624 2140 2631 4088 6155 1014 1470 1955 2467 3734 6335 1449 2119 2792 3458 5334 8889 164 157 153 148 139 124 163 157 153 148 139 127 206 198 193 187 175 156 206 198 193 187 175 156 206 198 193 187 175 160 198 191 186 180 168 150 198 190 186 180 168 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50E2001-D-8x 80 BXRC-50G2001-B-8x 90 BXRC-50G2001-C-8x 90 BXRC-50G2001-D-8x 90 BXRC-57C2001-B-8x 70 BXRC-57C2001-C-8x 70 BXRC-57C2001-D-8x 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 1187 1736 2287 2812 4369 6579 974 1412 1877 2370 3586 6085 1391 2035 2682 3321 5123 8538 1026 1500 1977 2430 3777 5687 1139 1652 2196 2772 4195 7119 1628 2381 3138 3886 5993 9989 1200 1755 2313 2843 4419 6653 1068 1562 2059 2530 3932 5921 877 1271 1690 2133 3227 5476 1252 1832 2414 2989 4610 7684 923 1350 1780 2187 3399 5118 1026 1487 1977 2495 3776 6407 1465 2143 2824 3497 5394 8990 1080 1580 2082 2559 3977 5988 198 190 185 180 168 154 172 165 161 155 146 129 171 165 160 155 145 130 171 164 160 155 145 133 201 193 188 182 170 151 200 193 188 182 170 152 200 192 187 182 170 156 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E2001-B-8x 80 BXRC-57E2001-C-8x 80 BXRC-57E2001-D-8x 80 BXRC-65C2001-B-8x 70 BXRC-65C2001-C-8x 70 BXRC-65C2001-D-8x 70 BXRC-65E2001-B-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 250 375 500 630 1000 1750 200 300 400 500 800 1250 175 260 350 450 700 1250 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 32.4 32.9 33.4 33.9 35.2 37.6 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 5.7 8.6 11.7 15.3 24.6 47.0 1082 1569 2086 2633 3984 6761 1546 2261 2980 3691 5692 9486 1140 1667 2197 2700 4196 6319 1139 1652 2196 2772 4195 7119 1628 2381 3138 3886 5993 9989 1200 1755 2313 2843 4419 6653 1095 1587 2111 2664 4031 6840 974 1412 1877 2370 3586 6085 1391 2035 2682 3321 5123 8538 1026 1500 1977 2430 3777 5687 1026 1487 1977 2495 3776 6407 1465 2143 2824 3497 5394 8990 1080 1580 2082 2559 3977 5988 985 1428 1899 2398 3628 6156 191 183 178 172 162 144 190 183 178 173 162 144 190 183 178 173 161 148 201 193 188 182 170 151 200 193 188 182 170 152 200 192 187 182 170 156 193 185 181 175 164 146 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 3: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-65E2001-C-8x 80 BXRC-65E2001-D-8x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 250 375 500 630 1000 1750 200 300 400 500 800 1250 32.5 33.0 33.4 33.9 35.2 37.5 30.0 30.4 30.9 31.3 32.5 34.1 8.1 12.4 16.7 21.4 35.2 65.7 6.0 9.1 12.3 15.6 26.0 42.7 1564 2288 3015 3734 5759 9598 1153 1687 2223 2732 4246 6393 1408 2059 2714 3361 5183 8638 1038 1518 2001 2459 3821 5754 193 185 180 175 164 146 192 185 180 175 163 150 Notes for Table 3: 1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Electrical Characteristics Table 4: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx200x-B-8x BXRC-xxx200x-C-8x BXRC-xxx200x-D-8x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.22 30.0 36.6 -12.13 0.34 33.8 41.2 35.9 -10.77 0.19 30.0 36.6 37.5 40.3 -12.10 0.29 33.7 41.1 28.6 30.9 33.2 -9.97 0.25 27.8 33.9 31.5 34.1 36.7 -11.00 0.38 30.7 37.4 Minimum Typical Maximum 350 30.9 33.4 35.9 -10.77 1250 34.8 37.6 40.4 500 30.9 33.4 1750 34.7 400 1250 Notes for Table 4: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application. 16 Eye Safety Table 5: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx200x-B-8x CCT Drive Current (mA) 2700K/3000K 4000K2 5000K3 6500K4 800 RG1 RG1 RG1 RG1 1110 RG1 RG1 RG1 RG2 1250 RG1 RG1 RG2 RG2 800 RG1 RG1 RG1 RG1 1110 RG1 RG1 RG1 RG2 1470 RG1 RG1 RG2 RG2 1750 RG1 RG2 RG2 RG2 865 RG1 RG1 RG1 RG1 1195 RG1 RG1 RG1 RG2 1250 RG1 RG1 RG2 RG2 BXRC-xxx200x-C-8x BXRC-xxx200x-D-8x Notes for Table 5: 1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1980 lx. 3. For products classified as RG2 at 5000K Ethr= 1530 lx. 4. For products classified as RG2 at 6500K, Ethr= 1170 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 17 Absolute Maximum Ratings Table 6: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx200x-B-8x BXRC-xxx200x-C-8x BXRC-xxx200x-D-8x Maximum Drive Current3 1250 mA 1750 mA 1250 mA Maximum Peak Pulsed Drive Current4 1400 mA 1960 mA 1400 mA Maximum Reverse Voltage5 -60V -60V -55V Notes for Table 6: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 18 Performance Curves Figure 2: Vero 13C Drive Current vs. Voltage 38.0 38.0 37.0 37.0 36.0 36.0 Voltage (V) Voltage (V) Figure 1: Vero 13B Drive Current vs. Voltage 35.0 34.0 35.0 34.0 33.0 33.0 32.0 32.0 0 150 300 450 600 750 900 1050 1200 0 1350 200 400 600 Figure 3: Vero 13D Drive Current vs. Voltage 350% 34.5 Relative Luminous Flux (%) 33.5 33.0 Voltage (V) 1000 1200 1400 1600 1800 2000 Figure 4: Vero 13B Typical Relative Flux vs. Current 34.0 32.5 32.0 31.5 31.0 30.5 30.0 300% 250% 200% 150% 100% 50% 0% 29.5 0 150 300 450 600 750 900 1050 1200 0 1350 150 300 Figure 5: Vero 13C Typical Relative Flux vs. Current 450 600 750 900 1050 1200 1350 Drive Current (mA) Drive Current (mA) Figure 6 Vero 13D Typical Relative Flux vs. Current 350% Relative Luminous Flux (%) 350% Relative Luminous Flux (%) 800 Drive Current (mA) Drive Current (mA) 300% 250% 200% 150% 100% 50% 300% 250% 200% 150% 100% 50% 0% 0% 0 200 400 600 800 1000 1200 1400 1600 1800 2000 Drive Current (mA) 0 150 300 450 600 750 900 1050 1200 1350 Drive Current (mA) Note for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 19 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature 102% 0.0010 100% 0.0000 25C Pulsed -0.0010 98% -0.0020 96% ccy shift Relative Luminous Flux Figure 7: Typical DC Flux vs. Case Temperature 94% 92% -0.0030 -0.0040 -0.0050 90% -0.0060 -0.0070 88% 0 20 40 60 80 100 120 0 20 40 60 80 100 120 Case Temperature (Tc) Case Temperature (Tc) Figure 9: Typical DC ccx Shift vs. Case Temperature 0.0020 25C Pulsed 0.0000 ccx shift -0.0020 -0.0040 -0.0060 -0.0080 -0.0100 0 20 40 60 80 100 120 Case Temperature (Tc) Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 20 Typical Radiation Pattern Figure 10: Typical Spatial Radiation Pattern Note for Figure 10: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 11: Typical Polar Radiation Pattern 21 Typical Color Spectrum Figure 12: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 12: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. 22 Mechanical Dimensions Figure 13: Drawing for Vero 13 LED Array Notes for Figure 13: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 23 Color Binning Information Figure 14: Warm and Neutral White Test Bins in xy Color Figure 15: Cool White Test Bins in xy Color Space Space 0.44 0.39 4 SDCM 3 SDCM 3 SDCM 0.38 2 SDCM 2700K 0.42 0.37 3000K 0.4 5000K 0.36 3500K 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 X 0.45 0.3 0.48 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2700K 3000K 3500K 4000K ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 83 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 82 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4073, 0.3917) (0.3818, 0.3797) Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 84 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 83 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 24 Packaging and Labeling Figure 16: Drawing for Vero 13 Packaging Tray Notes for Figure 16: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 25 Packaging and Labeling Figure 17: Vero Series Packaging and Labeling Notes for Figure 17: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 18: Gen. 8 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E2000C 83 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 26 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 27 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 8 Vero 13 Array Series Product Data Sheet DS421 Rev. A (07/2020) 28
BXRC-40E2000-D-83 价格&库存

很抱歉,暂时无法提供与“BXRC-40E2000-D-83”相匹配的价格&库存,您可以联系我们找货

免费人工找货