Bridgelux Gen 8 Vero 13 Array
®
®
Product Data Sheet DS421
1
Vero® Series
Introduction
The Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation, simplifying
the luminaire design and manufacturing processes. Vero Chip on Board (COB) LED arrays are available in four LES
configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero
arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Features
Benefits
• On board connector port
• Solder free installation and field upgradability
• Top side part number markings
• Improved inventory management and quality control
• Efficacy of 178 lm/W typical, 3000K 80 CRI
• Enables high efficiency lighting systems and lower
operating costs
• Reliable operation at up to 3x nominal current, 30%
increase in maximum lumens per LES size
• Wide selection of CCT options (2700K-6500K) with
minimum 70, 80 and 90 CRI options
• Uniform high-quality illumination
• 2 and 3 SDCM binning options (2700K – 4000K)
• Forward voltage bin codes (backside marking)
• Thermally isolated solder pads
• 10-Year warranty
• Supports the trend toward luminaire miniaturization
and delivers enhanced optical control
• Design flexibility for a broad range of lighting
applications
• Clean white light without pixelation
• Uniform consistent white light
• Design flexibility for multi-source applications
• Enhanced ease of use and installation
• Design with confidence
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
7
Electrical Characteristics
16
Eye Safety
17
Absolute Maximum Ratings
18
Performance Curves
19
Typical Radiation Pattern
21
Typical Color Spectrum
22
Mechanical Dimensions
23
Color Binning Information
24
Packaging and Labeling
25
Design Resources
27
Precautions
27
Disclaimers
27
About Bridgelux
28
1
Product Feature Map
Vero 13 is the second smallest form factor in the Vero
family of the next generation solid state light sources. In
addition to delivering the performance and light quality
required for many lighting applications, Vero incorporates
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
2D Bar code provides full manufacturing traceability
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
Optics location/mounting features
Correlates to the true case temperature
on the back surface of the LED array
Mounting holes
Radial die configuration improves lumen
density and beam control
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRC – 30 E 200 0 – C – 8 3
CCT Bin Options
Product Family
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen. 8
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
200x = 2000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E2000-B-8x
2700
80
350
1963
1767
33.4
11.7
168
BXRC-27E2000-C-8x
2700
80
500
2805
2524
33.4
16.7
168
BXRC-27E2000-D-8x
2700
80
400
2068
1861
30.9
12.4
167
139
BXRC-27G2000-B-8x
2700
90
350
1620
1458
33.4
11.7
BXRC-27G2000-C-8x
2700
90
500
2314
2082
33.4
16.7
139
BXRC-27G2000-D-8x
2700
90
400
1706
1535
30.9
12.4
138
BXRC-27G20H0-B-8x
2700
90
350
1690
1521
33.4
11.7
145
BXRC-27G20H0-C-8x
2700
90
500
2414
2172
33.4
16.7
145
BXRC-27G20H0-D-8x
2700
90
400
1780
1602
30.9
12.4
144
187
BXRC-30C2001-B-8x
3000
70
350
2184
1966
33.4
11.7
BXRC-30C2001-C-8x
3000
70
500
3120
2808
33.4
16.7
187
BXRC-30C2001-D-8x
3000
70
400
2300
2070
30.9
12.4
186
BXRC-30E2000-B-8x
3000
80
350
2086
1877
33.4
11.7
178
BXRC-30E2000-C-8x
3000
80
500
2980
2682
33.4
16.7
178
BXRC-30E2000-D-8x
3000
80
400
2197
1977
30.9
12.4
178
BXRC-30G2000-B-8x
3000
90
350
1693
1524
33.4
11.7
145
BXRC-30G2000-C-8x
3000
90
500
2419
2177
33.4
16.7
145
BXRC-30G2000-D-8x
3000
90
400
1783
1605
30.9
12.4
144
BXRC-30G20H0-B-8x
3000
90
350
1773
1596
33.4
11.7
152
BXRC-30G20H0-C-8x
3000
90
500
2533
2280
33.4
16.7
152
BXRC-30G20H0-D-8x
3000
90
400
1867
1681
30.9
12.4
151
BXRC-35E2000-B-8x
3500
80
350
2135
1922
33.4
11.7
183
BXRC-35E2000-C-8x
3500
80
500
3050
2745
33.4
16.7
183
BXRC-35E2000-D-8x
3500
80
400
2249
2024
30.9
12.4
182
BXRC-35G2000-B-8x
3500
90
350
1755
1579
33.4
11.7
150
BXRC-35G2000-C-8x
3500
90
500
2507
2256
33.4
16.7
150
BXRC-35G2000-D-8x
3500
90
400
1848
1663
30.9
12.4
150
BXRC-40C2001-B-8x
4000
70
350
2246
2021
33.4
11.7
192
BXRC-40C2001-C-8x
4000
70
500
3208
2887
33.4
16.7
192
BXRC-40C2001-D-8x
4000
70
400
2365
2129
30.9
12.4
191
BXRC-40E2000-B-8x
4000
80
350
2147
1933
33.4
11.7
184
BXRC-40E2000-C-8x
4000
80
500
3068
2761
33.4
16.7
184
BXRC-40E2000-D-8x
4000
80
400
2262
2035
30.9
12.4
183
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9
value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-40G2000-B-8x
4000
90
350
1792
1612
33.4
11.7
153
153
BXRC-40G2000-C-8x
4000
90
500
2559
2303
33.4
16.7
BXRC-40G2000-D-8x
4000
90
400
1887
1698
30.9
12.4
153
BXRC-50C2001-B-8x
5000
70
350
2258
2032
33.4
11.7
193
193
BXRC-50C2001-C-8x
5000
70
500
3225
2903
33.4
16.7
BXRC-50C2001-D-8x
5000
70
400
2378
2140
30.9
12.4
192
BXRC-50E2001-B-8x
5000
80
350
2172
1955
33.4
11.7
186
BXRC-50E2001-C-8x
5000
80
500
3103
2792
33.4
16.7
186
BXRC-50E2001-D-8x
5000
80
400
2287
2059
30.9
12.4
185
BXRC-50G2001-B-8x
5000
90
350
1877
1690
33.4
11.7
161
BXRC-50G2001-C-8x
5000
90
500
2682
2414
33.4
16.7
161
BXRC-50G2001-D-8x
5000
90
400
1977
1780
30.9
12.4
160
BXRC-57C2001-B-8x
5700
70
350
2196
1977
33.4
11.7
188
BXRC-57C2001-C-8x
5700
70
500
3138
2824
33.4
16.7
188
BXRC-57C2001-D-8x
5700
70
400
2313
2082
30.9
12.4
187
BXRC-57E2001-B-8x
5700
80
350
2086
1877
33.4
11.7
178
BXRC-57E2001-C-8x
5700
80
500
2980
2682
33.4
16.7
178
BXRC-57E2001-D-8x
5700
80
400
2197
1977
30.9
12.4
178
BXRC-65C2001-B-8x
6500
70
350
2196
1977
33.4
11.7
188
BXRC-65C2001-C-8x
6500
70
500
3138
2824
33.4
16.7
188
BXRC-65C2001-D-8x
6500
70
400
2313
2082
30.9
12.4
187
BXRC-65E2001-B-8x
6500
80
350
2111
1899
33.4
11.7
181
BXRC-65E2001-C-8x
6500
80
500
3015
2714
33.4
16.7
181
BXRC-65E2001-D-8x
6500
80
400
2223
2001
30.9
12.4
180
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux maintains
a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
4
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E2000-B-8x
2700
80
350
1767
1590
32.7
11.4
154
BXRC-27E2000-C-8x
2700
80
500
2524
2272
32.7
16.3
154
BXRC-27E2000-D-8x
2700
80
400
1861
1675
30.2
12.1
154
BXRC-27G2000-B-8x
2700
90
350
1458
1312
32.7
11.4
127
BXRC-27G2000-C-8x
2700
90
500
2082
1874
32.7
16.3
127
BXRC-27G2000-D-8x
2700
90
400
1535
1382
30.2
12.1
127
BXRC-27G20H0-B-8x
2700
90
350
1521
1369
32.7
11.4
133
BXRC-27G20H0-C-8x
2700
90
500
2172
1955
32.7
16.3
133
BXRC-27G20H0-D-8x
2700
90
400
1602
1441
30.2
12.1
132
BXRC-30C2001-B-8x
3000
70
350
1966
1769
32.7
11.4
172
BXRC-30C2001-C-8x
3000
70
500
2808
2527
32.7
16.3
172
BXRC-30C2001-D-8x
3000
70
400
2070
1863
30.2
12.1
171
BXRC-30E2000-B-8x
3000
80
350
1877
1690
32.7
11.4
164
BXRC-30E2000-C-8x
3000
80
500
2682
2414
32.7
16.3
164
BXRC-30E2000-D-8x
3000
80
400
1977
1780
30.2
12.1
164
BXRC-30G2000-B-8x
3000
90
350
1524
1372
32.7
11.4
133
133
BXRC-30G2000-C-8x
3000
90
500
2177
1959
32.7
16.3
BXRC-30G2000-D-8x
3000
90
400
1605
1445
30.2
12.1
133
BXRC-30G20H0-B-8x
3000
90
350
1596
1436
32.7
11.4
140
140
BXRC-30G20H0-C-8x
3000
90
500
2280
2052
32.7
16.3
BXRC-30G20H0-D-8x
3000
90
400
1681
1513
30.2
12.1
139
BXRC-35E2000-B-8x
3500
80
350
1922
1729
32.7
11.4
168
BXRC-35E2000-C-8x
3500
80
500
2745
2471
32.7
16.3
168
BXRC-35E2000-D-8x
3500
80
400
2024
1821
30.2
12.1
167
BXRC-35G2000-B-8x
3500
90
350
1579
1421
32.7
11.4
138
BXRC-35G2000-C-8x
3500
90
500
2256
2030
32.7
16.3
138
BXRC-35G2000-D-8x
3500
90
400
1663
1497
30.2
12.1
138
BXRC-40C2001-B-8x
4000
70
350
2021
1819
32.7
11.4
177
BXRC-40C2001-C-8x
4000
70
500
2887
2598
32.7
16.3
177
BXRC-40C2001-D-8x
4000
70
400
2129
1916
30.2
12.1
176
BXRC-40E2000-B-8x
4000
80
350
1933
1739
32.7
11.4
169
BXRC-40E2000-C-8x
4000
80
500
2761
2485
32.7
16.3
169
BXRC-40E2000-D-8x
4000
80
400
2035
1832
30.2
12.1
168
141
BXRC-40G2000-B-8x
4000
90
350
1612
1451
32.7
11.4
BXRC-40G2000-C-8x
4000
90
500
2303
2073
32.7
16.3
141
BXRC-40G2000-D-8x
4000
90
400
1698
1528
30.2
12.1
140
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux
maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50C2001-B-8x
5000
70
350
2032
1829
32.7
11.4
178
BXRC-50C2001-C-8x
5000
70
500
2903
2613
32.7
16.3
178
BXRC-50C2001-D-8x
5000
70
400
2140
1926
30.2
12.1
177
BXRC-50E2001-B-8x
5000
80
350
1955
1759
32.7
11.4
171
BXRC-50E2001-C-8x
5000
80
500
2792
2513
32.7
16.3
171
BXRC-50E2001-D-8x
5000
80
400
2059
1853
30.2
12.1
170
BXRC-50G2001-B-8x
5000
90
350
1690
1521
32.7
11.4
148
BXRC-50G2001-C-8x
5000
90
500
2414
2172
32.7
16.3
148
BXRC-50G2001-D-8x
5000
90
400
1780
1602
30.2
12.1
147
BXRC-57C2001-B-8x
5700
70
350
1977
1779
32.7
11.4
173
BXRC-57C2001-C-8x
5700
70
500
2824
2542
32.7
16.3
173
BXRC-57C2001-D-8x
5700
70
400
2082
1874
30.2
12.1
172
BXRC-57E2001-B-8x
5700
80
350
1877
1690
32.7
11.4
164
BXRC-57E2001-C-8x
5700
80
500
2682
2414
32.7
16.3
164
BXRC-57E2001-D-8x
5700
80
400
1977
1780
30.2
12.1
164
BXRC-65C2001-B-8x
6500
70
350
1977
1779
32.7
11.4
173
BXRC-65C2001-C-8x
6500
70
500
2824
2542
32.7
16.3
173
BXRC-65C2001-D-8x
6500
70
400
2082
1874
30.2
12.1
172
BXRC-65E2001-B-8x
6500
80
350
1899
1710
32.7
11.4
166
BXRC-65E2001-C-8x
6500
80
500
2714
2442
32.7
16.3
166
BXRC-65E2001-D-8x
6500
80
400
2001
1801
30.2
12.1
165
Notes for Table 2:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50. Bridgelux
maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 3.
Table 3: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-27E2000-B-8x
80
BXRC-27E2000-C-8x
80
BXRC-27E2000-D-8x
80
BXRC-27G2000-B-8x
90
BXRC-27G2000-C-8x
90
BXRC-27G2000-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
1019
1476
1963
2478
3750
6363
1455
2128
2805
3473
5357
8928
1073
1569
2068
2542
3950
5947
840
1218
1620
2044
3094
5250
1200
1756
2314
2866
4420
7366
885
1295
1706
2097
3258
4906
917
1329
1767
2230
3375
5727
1310
1916
2524
3126
4821
8035
965
1412
1861
2287
3555
5352
756
1096
1458
1840
2784
4725
1080
1580
2082
2579
3978
6629
797
1165
1535
1887
2933
4416
179
173
168
162
152
135
179
172
168
163
152
136
179
172
168
163
152
139
148
142
139
134
126
112
148
142
138
134
126
112
148
142
138
134
125
115
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
7
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27G20H0-B-8x
90
BXRC-27G20H0-C-8x
90
BXRC-27G20H0-D-8x
90
BXRC-30C2001-B-8x
70
BXRC-30C2001-C-8x
70
BXRC-30C2001-D-8x
70
BXRC-30E2000-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
877
1271
1690
2133
3227
5476
1252
1832
2414
2989
4610
7684
923
1350
1780
2187
3399
5118
1133
1643
2184
2757
4172
7079
1619
2368
3120
3864
5960
9933
1193
1746
2300
2828
4394
6616
1082
1569
2086
2633
3984
6761
789
1144
1521
1920
2905
4929
1127
1649
2172
2690
4149
6916
831
1215
1602
1969
3059
4606
1020
1478
1966
2481
3755
6371
1457
2131
2808
3478
5364
8939
1074
1571
2070
2545
3954
5954
974
1412
1877
2370
3586
6085
154
149
145
140
131
117
154
148
144
140
131
117
154
148
144
140
131
120
200
192
187
181
169
151
199
192
187
181
169
151
199
191
186
181
169
155
191
183
178
172
162
144
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30E2000-C-8x
80
BXRC-30E2000-D-8x
80
BXRC-30G2000-B-8x
90
BXRC-30G2000-C-8x
90
BXRC-30G2000-D-8x
90
BXRC-30G20H0-B-8x
90
BXRC-30G20H0-C-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
1546
2261
2980
3691
5692
9486
1140
1667
2197
2700
4196
6319
878
1273
1693
2137
3234
5488
1255
1836
2419
2996
4621
7701
925
1353
1783
2192
3406
5129
920
1333
1773
2238
3387
5747
1314
1922
2533
3137
4838
8063
1391
2035
2682
3321
5123
8538
1026
1500
1977
2430
3777
5687
791
1146
1524
1924
2911
4939
1129
1652
2177
2696
4158
6931
833
1218
1605
1973
3066
4616
828
1200
1596
2014
3048
5172
1183
1730
2280
2823
4354
7257
190
183
178
173
162
144
190
183
178
173
161
148
155
149
145
140
131
117
155
149
145
140
131
117
154
148
145
140
131
120
162
156
152
147
138
122
162
156
152
147
137
123
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
9
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G20H0-D-8x
90
BXRC-35E2000-B-8x
80
BXRC-35E2000-C-8x
80
BXRC-35E2000-D-8x
80
BXRC-35G2000-B-8x
90
BXRC-35G2000-C-8x
90
BXRC-35G2000-D-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
969
1417
1867
2295
3567
5371
1108
1606
2135
2695
4078
6920
1582
2315
3050
3777
5826
9710
1167
1706
2249
2764
4295
6467
910
1320
1755
2215
3352
5687
1300
1902
2507
3104
4788
7980
959
1402
1848
2272
3530
5315
872
1275
1681
2066
3210
4834
997
1445
1922
2426
3670
6228
1424
2083
2745
3400
5243
8739
1050
1536
2024
2488
3866
5821
819
1188
1579
1993
3016
5118
1170
1712
2256
2794
4309
7182
863
1262
1663
2044
3177
4784
162
155
151
147
137
126
195
188
183
177
166
147
195
187
182
177
165
148
195
187
182
177
165
152
160
154
150
145
136
121
160
154
150
145
136
121
160
154
150
145
136
125
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C2001-B-8x
70
BXRC-40C2001-C-8x
70
BXRC-40C2001-D-8x
70
BXRC-40E2000-B-8x
80
BXRC-40E2000-C-8x
80
BXRC-40E2000-D-8x
80
BXRC-40G2000-B-8x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
1165
1689
2246
2834
4289
7278
1664
2434
3208
3973
6127
10212
1227
1795
2365
2907
4517
6802
1114
1615
2147
2711
4102
6960
1591
2328
3068
3799
5859
9765
1173
1716
2262
2780
4320
6505
929
1347
1792
2261
3422
5806
1048
1520
2021
2551
3860
6550
1498
2191
2887
3575
5514
9191
1104
1615
2129
2616
4066
6122
1003
1453
1933
2439
3691
6264
1432
2095
2761
3419
5273
8789
1056
1545
2035
2502
3888
5854
836
1213
1612
2035
3080
5226
205
197
192
186
174
155
205
197
192
186
174
155
205
197
192
186
174
159
196
189
184
178
167
148
196
188
184
178
166
149
196
188
183
178
166
152
164
157
153
148
139
124
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40G2000-C-8x
90
BXRC-40G2000-D-8x
90
BXRC-50C2001-B-8x
70
BXRC-50C2001-C-8x
70
BXRC-50C2001-D-8x
70
BXRC-50E2001-B-8x
80
BXRC-50E2001-C-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
1328
1942
2559
3170
4888
8147
979
1432
1887
2319
3604
5427
1171
1698
2258
2850
4312
7318
1673
2448
3225
3994
6161
10268
1234
1805
2378
2923
4542
6839
1127
1633
2172
2741
4148
7039
1610
2355
3103
3842
5926
9877
1195
1748
2303
2853
4400
7332
881
1289
1698
2087
3244
4884
1054
1528
2032
2565
3881
6586
1506
2203
2903
3595
5545
9241
1110
1624
2140
2631
4088
6155
1014
1470
1955
2467
3734
6335
1449
2119
2792
3458
5334
8889
164
157
153
148
139
124
163
157
153
148
139
127
206
198
193
187
175
156
206
198
193
187
175
156
206
198
193
187
175
160
198
191
186
180
168
150
198
190
186
180
168
150
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50E2001-D-8x
80
BXRC-50G2001-B-8x
90
BXRC-50G2001-C-8x
90
BXRC-50G2001-D-8x
90
BXRC-57C2001-B-8x
70
BXRC-57C2001-C-8x
70
BXRC-57C2001-D-8x
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
1187
1736
2287
2812
4369
6579
974
1412
1877
2370
3586
6085
1391
2035
2682
3321
5123
8538
1026
1500
1977
2430
3777
5687
1139
1652
2196
2772
4195
7119
1628
2381
3138
3886
5993
9989
1200
1755
2313
2843
4419
6653
1068
1562
2059
2530
3932
5921
877
1271
1690
2133
3227
5476
1252
1832
2414
2989
4610
7684
923
1350
1780
2187
3399
5118
1026
1487
1977
2495
3776
6407
1465
2143
2824
3497
5394
8990
1080
1580
2082
2559
3977
5988
198
190
185
180
168
154
172
165
161
155
146
129
171
165
160
155
145
130
171
164
160
155
145
133
201
193
188
182
170
151
200
193
188
182
170
152
200
192
187
182
170
156
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57E2001-B-8x
80
BXRC-57E2001-C-8x
80
BXRC-57E2001-D-8x
80
BXRC-65C2001-B-8x
70
BXRC-65C2001-C-8x
70
BXRC-65C2001-D-8x
70
BXRC-65E2001-B-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
250
375
500
630
1000
1750
200
300
400
500
800
1250
175
260
350
450
700
1250
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
32.4
32.9
33.4
33.9
35.2
37.6
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
5.7
8.6
11.7
15.3
24.6
47.0
1082
1569
2086
2633
3984
6761
1546
2261
2980
3691
5692
9486
1140
1667
2197
2700
4196
6319
1139
1652
2196
2772
4195
7119
1628
2381
3138
3886
5993
9989
1200
1755
2313
2843
4419
6653
1095
1587
2111
2664
4031
6840
974
1412
1877
2370
3586
6085
1391
2035
2682
3321
5123
8538
1026
1500
1977
2430
3777
5687
1026
1487
1977
2495
3776
6407
1465
2143
2824
3497
5394
8990
1080
1580
2082
2559
3977
5988
985
1428
1899
2398
3628
6156
191
183
178
172
162
144
190
183
178
173
162
144
190
183
178
173
161
148
201
193
188
182
170
151
200
193
188
182
170
152
200
192
187
182
170
156
193
185
181
175
164
146
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-65E2001-C-8x
80
BXRC-65E2001-D-8x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
250
375
500
630
1000
1750
200
300
400
500
800
1250
32.5
33.0
33.4
33.9
35.2
37.5
30.0
30.4
30.9
31.3
32.5
34.1
8.1
12.4
16.7
21.4
35.2
65.7
6.0
9.1
12.3
15.6
26.0
42.7
1564
2288
3015
3734
5759
9598
1153
1687
2223
2732
4246
6393
1408
2059
2714
3361
5183
8638
1038
1518
2001
2459
3821
5754
193
185
180
175
164
146
192
185
180
175
163
150
Notes for Table 3:
1. Alternate drive currents in Table 3 are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Electrical Characteristics
Table 4: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx200x-B-8x
BXRC-xxx200x-C-8x
BXRC-xxx200x-D-8x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.22
30.0
36.6
-12.13
0.34
33.8
41.2
35.9
-10.77
0.19
30.0
36.6
37.5
40.3
-12.10
0.29
33.7
41.1
28.6
30.9
33.2
-9.97
0.25
27.8
33.9
31.5
34.1
36.7
-11.00
0.38
30.7
37.4
Minimum
Typical
Maximum
350
30.9
33.4
35.9
-10.77
1250
34.8
37.6
40.4
500
30.9
33.4
1750
34.7
400
1250
Notes for Table 4:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1140 V. The working
voltage designated for the insulation is 70V d.c. The maximum allowable voltage across the array must be determined in the end product application.
16
Eye Safety
Table 5: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx200x-B-8x
CCT
Drive Current
(mA)
2700K/3000K
4000K2
5000K3
6500K4
800
RG1
RG1
RG1
RG1
1110
RG1
RG1
RG1
RG2
1250
RG1
RG1
RG2
RG2
800
RG1
RG1
RG1
RG1
1110
RG1
RG1
RG1
RG2
1470
RG1
RG1
RG2
RG2
1750
RG1
RG2
RG2
RG2
865
RG1
RG1
RG1
RG1
1195
RG1
RG1
RG1
RG2
1250
RG1
RG1
RG2
RG2
BXRC-xxx200x-C-8x
BXRC-xxx200x-D-8x
Notes for Table 5:
1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1980 lx.
3. For products classified as RG2 at 5000K Ethr= 1530 lx.
4. For products classified as RG2 at 6500K, Ethr= 1170 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
17
Absolute Maximum Ratings
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx200x-B-8x
BXRC-xxx200x-C-8x
BXRC-xxx200x-D-8x
Maximum Drive Current3
1250 mA
1750 mA
1250 mA
Maximum Peak Pulsed Drive Current4
1400 mA
1960 mA
1400 mA
Maximum Reverse Voltage5
-60V
-60V
-55V
Notes for Table 6:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced and warranty will not apply.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
18
Performance Curves
Figure 2: Vero 13C Drive Current vs. Voltage
38.0
38.0
37.0
37.0
36.0
36.0
Voltage (V)
Voltage (V)
Figure 1: Vero 13B Drive Current vs. Voltage
35.0
34.0
35.0
34.0
33.0
33.0
32.0
32.0
0
150
300
450
600
750
900
1050
1200
0
1350
200
400
600
Figure 3: Vero 13D Drive Current vs. Voltage
350%
34.5
Relative Luminous Flux (%)
33.5
33.0
Voltage (V)
1000 1200 1400 1600 1800 2000
Figure 4: Vero 13B Typical Relative Flux vs. Current
34.0
32.5
32.0
31.5
31.0
30.5
30.0
300%
250%
200%
150%
100%
50%
0%
29.5
0
150
300
450
600
750
900
1050
1200
0
1350
150
300
Figure 5: Vero 13C Typical Relative Flux vs. Current
450
600
750
900
1050
1200
1350
Drive Current (mA)
Drive Current (mA)
Figure 6 Vero 13D Typical Relative Flux vs. Current
350%
Relative Luminous Flux (%)
350%
Relative Luminous Flux (%)
800
Drive Current (mA)
Drive Current (mA)
300%
250%
200%
150%
100%
50%
300%
250%
200%
150%
100%
50%
0%
0%
0
200
400
600
800
1000 1200 1400 1600 1800 2000
Drive Current (mA)
0
150
300
450
600
750
900
1050
1200
1350
Drive Current (mA)
Note for Figure 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
19
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
102%
0.0010
100%
0.0000
25C Pulsed
-0.0010
98%
-0.0020
96%
ccy shift
Relative Luminous Flux
Figure 7: Typical DC Flux vs. Case Temperature
94%
92%
-0.0030
-0.0040
-0.0050
90%
-0.0060
-0.0070
88%
0
20
40
60
80
100
120
0
20
40
60
80
100
120
Case Temperature (Tc)
Case Temperature (Tc)
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.0020
25C Pulsed
0.0000
ccx shift
-0.0020
-0.0040
-0.0060
-0.0080
-0.0100
0
20
40
60
80
100
120
Case Temperature (Tc)
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
20
Typical Radiation Pattern
Figure 10: Typical Spatial Radiation Pattern
Note for Figure 10:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 11: Typical Polar Radiation Pattern
21
Typical Color Spectrum
Figure 12: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 12:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
22
Mechanical Dimensions
Figure 13: Drawing for Vero 13 LED Array
Notes for Figure 13:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
23
Color Binning Information
Figure 14: Warm and Neutral White Test Bins in xy Color
Figure 15: Cool White Test Bins in xy Color Space
Space
0.44
0.39
4 SDCM
3 SDCM
3 SDCM
0.38
2 SDCM
2700K
0.42
0.37
3000K
0.4
5000K
0.36
3500K
5700K
0.35
Y
Y
4000K
0.34
0.38
6500K
0.33
0.36
0.32
0.31
0.34
0.36
0.39
0.42
X
0.45
0.3
0.48
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 7: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
2700K
3000K
3500K
4000K
ANSI Bin
(for reference only)
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
83 (3 SDCM)
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
82 (2 SDCM)
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Table 8: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5312K - 6022K)
(6022K - 7042K)
84 (4 SDCM)
(4801K - 5282K)
(5829K - 5481K)
(6270K - 6765K)
83 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3287, 0.3417)
(0.3123, 0.3282)
24
Packaging and Labeling
Figure 16: Drawing for Vero 13 Packaging Tray
Notes for Figure 16:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
25
Packaging and Labeling
Figure 17: Vero Series Packaging and Labeling
Notes for Figure 17:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 18: Gen. 8 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E2000C 83 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
26
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
27
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2020 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series
HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 8 Vero 13 Array Series Product Data Sheet DS421 Rev. A (07/2020)
28