Bridgelux Gen 7 V10 Thrive™ Array
Product Data Sheet DS320
1
| | | | | |
BXRE-27S 30S 35S 40S 50S 57S 65S
V10 Thrive
Introduction
Bridgelux Thrive™ combines unique chip, phosphor and packaging technology to closely match the spectra of natural
light over the visible wavelength range. Thrive can be used in constant color point luminaires to bring full spectrum
natural light indoors or in tunable white luminaires to incorporate circadian elements that may impact human well-being.
The high fidelity spectral output of Thrive creates stunning environments with excellent color rendering and outstanding
TM30 metrics. Thrive is available in both SMD components and LED arrays to enable a broad range of lighting
applications including retail, hospitality, office, education, architectural, museums, healthcare and residential lighting.
Features
Benefits
• Engineered spectrum to closely match natural light
• Full consistent spectrum with fewer spectral spikes
• CRI >95, R1-R15 >90, high Rf and Rg values
• Natural and vivid color rendering
• High efficacy full spectrum solution
• Greater energy savings, lower utility costs
• No violet chip augmentation
• Economical, high efficiency solution
• Hot color targeted
• Uniform and consistent white light at application
conditions
• Form factor consistent with existing Bridgelux COB
arrays
• Broad product platform availability (SMDs and COBs)
• Ease of design and rapid go-to-market
• Enables greater design flexibility and platform color
consistency
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Spectrum Characteristics
6
Electrical Characteristics
9
Absolute Maximum Ratings
10
Eye Safety
11
Product Bin Definitions
12
Performance Curves
13
Typical Radiation Pattern
15
Mechanical Dimensions
16
Packaging and Labeling
17
Design Resources
19
Precautions
19
Disclaimers
19
About Bridgelux
20
1
Product Feature Map
Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered
mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array
products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com
for more information on the V Series family of products.
Polarity symbols
White ring around LES
Fully engineered substrate
for consistent thermal, mechanical
and optical properties
Case Temperature (Tc)
Measurement Point
Solder Pads
Note: Part number and lot codes are scribed on back of array
Product Nomenclature
The part number designation for Bridgelux COB arrays is explained as follows:
1 2 3 4
– 5 6 7 8 9 10 11
– 12
– 13 14
BXRE – 30 S 1000 – C –
7 3
CCT Bin Options
Product Family
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen 7
Array Configuration
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Flux Indicator
1001 = 1000 lm
Minimum CRI
S = Thrive
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tc= 25°C)
Part Number1,6
Nominal
CCT1
(K)
CRI
2
Nominal
Drive
Current3
(mA)
Typical Vf
(V)
Typical
Pulsed
Flux4,5,6,7
Tc = 25ºC
(lm)
Minimum
Pulsed
Flux6,7,8
Tc = 25ºC
(lm)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
Typical
Photosynthetic
Photon Flux
(PPF)
Typical
Photon
Efficiency
(µmol/J)
BXRE-27S1001-B-7x
2700
95
270
34.4
1003
883
9.3
108
17.50
1.90
BXRE-27S1001-C-7x
2700
95
360
34.4
1337
1177
12.4
108
23.33
1.90
BXRE-30S1001-B-7x
3000
95
270
34.4
1077
948
9.3
116
18.40
1.99
BXRE-30S1001-C-7x
3000
95
360
34.4
1437
1264
12.4
116
24.55
1.99
BXRE-35S1001-B-7x
3500
95
270
34.4
1124
989
9.3
121
18.60
1.99
BXRE-35S1001-C-7x
3500
95
360
34.4
1498
1319
12.4
121
24.79
1.99
BXRE-40S1001-B-7x
4000
95
270
34.4
1142
1005
9.3
123
18.59
1.97
BXRE-40S1001-C-7x
4000
95
360
34.4
1523
1340
12.4
123
24.79
1.97
BXRE-50S1001-B-74
5000
95
270
34.4
1198
1054
9.3
129
19.64
2.06
BXRE-50S1001-C-74
5000
95
360
34.4
1598
1406
12.4
129
26.19
2.06
2.10
BXRE-57S1001-B-74
5700
95
270
34.4
1226
1079
9.3
132
20.16
BXRE-57S1001-C-74
5700
95
360
34.4
1635
1439
12.4
132
26.88
2.10
BXRE-65S1001-B-74
6500
95
270
34.4
1207
1063
9.3
130
19.85
2.07
BXRE-65S1001-C-74
6500
95
360
34.4
1610
1417
12.4
130
26.47
2.07
Minimum DC
Flux6,7,8,9
Tc = 85ºC
(lm)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
Typical
Photosynthetic
Photon Flux
(PPF)
Typical
Photon
Efficiency
(µmol/J)
Table 2: Selection Guide, Stabilized DC Test Performance (Tc= 85°C)4,5,6
Part Number1,6
Nominal
CCT1
(K)
CRI2
Nominal
Drive
Current3
(mA)
Typical Vf
(V)
Typical DC
Flux4,5,6,7
Tc = 85ºC
(lm)
BXRE-27S1001-B-7x
2700
95
270
33.7
903
794
9.1
99
15.76
1.90
BXRE-27S1001-C-7x
2700
95
360
33.7
1204
1059
12.1
99
21.01
1.90
BXRE-30S1001-B-7x
3000
95
270
33.7
970
853
9.1
107
16.57
1.99
BXRE-30S1001-C-7x
3000
95
360
33.7
1293
1138
12.1
107
22.09
1.99
BXRE-35S1001-B-7x
3500
95
270
33.7
1011
890
9.1
111
16.73
1.99
BXRE-35S1001-C-7x
3500
95
360
33.7
1349
1187
12.1
111
22.33
1.99
BXRE-40S1001-B-7x
4000
95
270
33.7
1028
905
9.1
113
16.73
1.97
BXRE-40S1001-C-7x
4000
95
360
33.7
1371
1206
12.1
113
22.31
1.97
BXRE-50S1001-B-74
5000
95
270
33.7
1078
949
9.1
119
17.67
2.06
BXRE-50S1001-C-74
5000
95
360
33.7
1438
1265
12.1
119
23.57
2.06
BXRE-57S1001-B-74
5700
95
270
33.7
1103
971
9.1
121
18.14
2.10
BXRE-57S1001-C-74
5700
95
360
33.7
1471
1295
12.1
121
24.19
2.10
BXRE-65S1001-B-74
6500
95
270
33.7
1087
956
9.1
119
17.87
2.07
BXRE-65S1001-C-74
6500
95
360
33.7
1449
1275
12.1
119
23.82
2.07
Notes for Table 1 & 2:
1. Product CCT is hot targeted at Tj= 85°C. Nominal CCT as defined by ANSI C78.377-2011.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are minimums. Bridgelux maintains a ± 3 tolerance on CRI values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. Typical stabilized DC
performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
7. Bridgelux maintains a ±7% tolerance on flux measurements.
8. Minimum flux values at the nominal test current are guaranteed by 100% test.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup,
values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
3
Performance at Commonly Used Drive Currents
V Series Thrive LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series
Thrive LED Arrays may also be driven at other drive currents dependent on specific application design requirements.
The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 10 &
11 and the flux vs. current characteristics shown in Figures 12 & 13. The performance at commonly used drive currents is
summarized in Table 3.
Table 3: Product Performance at Commonly Used Drive Currents
Part Number
BXRE-27S1001-B-7x
BXRE-27S1001-C-7x
BXRE-30S1001-B-7x
BXRE-30S1001-C-7x
BXRE-35S1001-B-7x
BXRE-35S1001-C-7x
BXRE-40S1001-B-7x
BXRE-40S1001-C-7x
CRI
95
95
95
95
95
95
95
95
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
32.8
4.4
535
480
121
180
33.6
6.1
701
629
116
270
34.4
9.3
1003
903
108
405
35.2
14.3
1472
1309
103
540
35.7
19.3
1885
1669
98
180
32.8
5.9
711
635
120
240
33.6
8.1
932
828
115
360
34.4
12.4
1337
1204
108
540
35.2
19.0
1948
1692
102
720
35.7
25.7
2488
2130
97
135
32.8
4.4
574
516
130
180
33.6
6.1
753
675
124
270
34.4
9.3
1077
970
116
405
35.2
14.3
1581
1406
111
540
35.7
19.3
2025
1792
105
129
180
32.8
5.9
764
682
240
33.6
8.1
1001
889
124
360
34.4
12.4
1437
1293
116
540
35.2
19.0
2092
1817
110
720
35.7
25.7
2672
2287
104
135
32.8
4.4
599
538
135
180
33.6
6.1
785
704
130
270
34.4
9.3
1124
1011
121
405
35.2
14.3
1649
1467
116
540
35.7
19.3
2112
1870
109
180
32.8
5.9
797
711
135
240
33.6
8.1
1044
927
129
360
34.4
12.4
1498
1349
121
540
35.2
19.0
2182
1896
115
720
35.7
25.7
2787
2386
108
137
135
32.8
4.4
609
547
180
33.6
6.1
798
716
132
270
34.4
9.3
1142
1028
123
405
35.2
14.3
1676
1491
117
540
35.7
19.3
2147
1900
111
180
32.8
5.9
810
723
137
240
33.6
8.1
1061
943
132
360
34.4
12.4
1523
1371
123
540
35.2
19.0
2218
1927
117
720
35.7
25.7
2833
2425
110
Notes for Table 3:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
4
Performance at Commonly Used Drive Currents
Table 3: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
BXRE-50S1001-B-74
BXRE-50S1001-C-74
BXRE-57S1001-B-74
BXRE-57S1001-C-74
BXRE-65S1001-B-74
BXRE-65S1001-C-74
CRI
95
95
95
95
95
95
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
32.8
4.4
638
574
144
180
33.6
6.1
837
751
138
270
34.4
9.3
1198
1078
129
405
35.2
14.3
1758
1564
123
540
35.7
19.3
2252
1993
117
180
32.8
5.9
849
758
144
240
33.6
8.1
1113
989
138
360
34.4
12.4
1598
1438
129
540
35.2
19.0
2326
2021
122
720
35.7
25.7
2972
2544
116
135
32.8
4.4
653
587
147
180
33.6
6.1
857
768
142
270
34.4
9.3
1226
1103
132
405
35.2
14.3
1799
1600
126
540
35.7
19.3
2304
2039
119
180
32.8
5.9
869
776
147
240
33.6
8.1
1139
1012
141
360
34.4
12.4
1635
1471
132
540
35.2
19.0
2380
2068
125
720
35.7
25.7
3041
2603
118
135
32.8
4.4
643
578
145
180
33.6
6.1
844
757
139
270
34.4
9.3
1207
1087
130
405
35.2
14.3
1771
1576
124
540
35.7
19.3
2269
2009
118
180
32.8
5.9
856
764
145
240
33.6
8.1
1121
996
139
360
34.4
12.4
1610
1449
130
540
35.2
19.0
2344
2037
123
720
35.7
25.7
2995
2563
116
Notes for Table 3:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5
Spectrum Characteristics
Table 4: Typical Color Rendering Index and TM-30 Values at, Tc=85°C
Nominal
CCT1
Rf
Rg
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
2700K
95
103
97
99
94
94
97
98
97
98
99
97
91
98
98
95
98
3000K
95
104
98
99
93
94
97
98
96
96
97
96
92
95
98
95
97
3500K
95
98
98
98
97
98
98
98
98
97
93
97
97
95
98
97
98
4000K
97
100
99
99
97
99
99
99
99
98
94
97
99
96
99
98
98
5000K
97
100
98
99
98
98
98
98
99
98
95
98
98
98
98
98
97
5700K
94
98
98
98
97
95
98
97
96
95
92
97
96
96
98
98
97
6500K
95
98
98
98
97
96
98
98
96
96
93
97
96
97
98
98
97
Note for Table 4:
1. Bridgelux maintains a tolerance of ± 3 on Color Rendering Index R1-R15 measurements and TM-30 measurements.
Figure 1: 2700K Thrive TM-30 Graphs
Figure 2: 3000K Thrive TM-30 Graphs
Figure 3: 3500K Thrive TM-30 Graphs
6
Spectrum Characteristics
Figure 4: 4000K Thrive TM-30 Graphs
Figure 5: 5000K Thrive TM-30 Graphs
Figure 6: 5700K Thrive TM30 Graphs
Figure 7: 6500K Thrive TM-30 Graphs
7
Spectrum Characteristics
Figure 8: Typical Color Spectrum
100%
100%
2700K
5000K
5700K
6500K
80%
Relative Radiant Power(%)
Relative Radiant Power(%)
3000K
3500K
4000K
60%
40%
20%
0%
350
400
450
500
550
600
650
700
750
800
Wavelength(nm)
80%
60%
40%
20%
0%
350
400
450
500
550
600
650
700
750
800
Wavelength(nm)
Note for Figure 8:
1. Color spectra measured at nominal current for Tj = 85°C.
Spectral Matching to Natural Light
The lighting market is in the early stages of adoption of human-centric lighting (HCL). HCL encompasses the effects of lighting on the physical and emotional
health and well-being of people. Throughout evolution, the human visual system has evolved under the natural light of sun and fire. These light sources have
standardized industry spectral power definitions that describe the state of natural light. However, conventional metrics such as CCT, CRI, and TM-30 fail to
adequately quantify the naturalness, or closeness of these light sources to the standardized natural spectra. Due to a lack of an industry standard metric to
quantitatively measure the naturalness of a light source, Bridgelux has pioneered a new metric that takes the guesswork out of comparing LED light sources
to natural light.
Average Spectral Difference, or ASD, is calculated by measuring the absolute difference between two spectra at discrete wavelengths. These values are averaged across a wavelength range derived from the photopic response curve, or V(λ); a luminous efficiency function describing the average spectral sensitivity
of human perception of brightness. The range of 425nm to 690nm was selected to remove the tails of the V(λ) gaussian distribution below 1% of the peak value
at 555nm, covering 99.9% of the area under the photopic response curve. Natural light is defined following the approach of IES TM-30; black body curves for
light sources of ≤4000K and the CIE standard illuminant D for light sources of ≥ 5000K.
Natural light has an ASD of 0%; lower ASD values indicate a closer match to natural light. Thrive is engineered to provide the closest match to natural light
available using proprietary chip, phosphor and packaging technology, resulting in an ASD between 8% to 10% for all CCTs. By comparison, standard 80, 90,
and 98 CRI light sources have ASD values that are 100% to 300% larger than Thrive. To learn more about the ASD metric, please contact your Bridgelux sales
representative. Bridgelux will publish a white paper to further educate the market about the benefits of the ASD metric in Q2 2020.
8
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRE-xxx1001-B-7x
BXRE-xxx1001-C-7x
Drive Current
(mA)
Minimum
Typical
Maximum
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
270
32.2
34.4
37.4
-16.1
0.49
30.9
38.5
540
33.4
35.7
38.8
-16.1
0.56
32.1
39.9
360
32.2
34.4
37.4
-16.1
0.37
30.9
38.5
720
33.4
35.7
38.8
-16.1
0.45
32.1
39.9
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working
voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
9
Absolute Maximum Ratings
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRE-xxx1001-B-7x
BXRE-xxx1001-C-7x
Maximum Drive Current3
540mA
720mA
Maximum Peak Pulsed Drive Current4
770mA
1030mA
Maximum Reverse Voltage5
-60V
-60V
Notes for Table 6:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
10
Eye Safety
Table 7: Eye Safety Risk Group (RG) Classifications
Part Number
BXRE-xxx100x-B-7x
BXRE-xxx100x-C-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
270
RG1
RG1
RG1
RG1
405
RG1
RG1
RG1
RG2
540
RG1
RG1
RG2
RG2
360
RG1
RG1
RG1
RG2
540
RG1
RG1
RG2
RG2
720
RG1
RG2
RG2
RG2
Notes for Table 7:
1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
11
Product Bin Definitions
Table 8: 2-, 3- and 4-step MacAdam Ellipse Color Bin Definitions
Center Point
Degree
2-step
3-step
4-step
CCT
x
y
Φ(°)
a
b
a
b
a
b
2700K
0.4578
0.4101
53.700
0.00540
0.00280
0.0081
0.0042
N/A
N/A
3000K
0.4338
0.403
53.217
0.00556
0.00272
0.0083
0.0041
N/A
N/A
4000K
0.3818
0.3797
53.717
0.00626
0.00268
0.0094
0.0040
N/A
N/A
5000K
0.3447
0.3553
59.617
N/A
N/A
0.0082
0.0035
0.0110
0.0047
5700K
0.3287
0.3417
59.060
N/A
N/A
0.0074
0.0032
0.0099
0.0042
6500K
0.3123
0.3282
58.567
N/A
N/A
0.0066
0.0028
0.0090
0.0038
Notes for Table 8:
1. Color binning at Tc=85°C
2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space.
Figure 9: C.I.E. 1931 Chromaticity Diagram (Color targeted at Tc=85°C)
0.44
0.39
3 SDCM
4 SDCM
2 SDCM
0.38
2700K
3 SDCM
0.42
3000K
0.37
3500K
5000K
0.36
0.4
5700K
0.35
Y
Y
4000K
0.38
6500K
0.34
0.33
0.36
0.32
0.34
0.36
0.31
0.39
0.42
0.45
X
0.48
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
X
12
Performance Curves
Figure 10: V10B Drive Current vs. Voltage (Tc=25°C)
Figure 11: V10C Drive Current vs. Voltage (Tc=25°C)
800
600
700
Forward Current (mA)
Forward Current(mA)
500
400
300
200
100
600
500
400
300
200
100
0
32.0
33.0
34.0
35.0
36.0
0
32.0
37.0
33.0
Figure 12: V10B Typical Relative Flux vs. Current (Tc=25°C)
35.0
36.0
37.0
Figure 13: V10C Typical Relative Flux vs. Current (Tc=25°C)
200%
200%
180%
180%
160%
160%
Relative Luminus Flux
Relative Luminus Flux
34.0
Forward Voltage (V)
Forward Voltage(V)
140%
120%
100%
80%
60%
40%
20%
140%
120%
100%
80%
60%
40%
20%
0%
0
100
200
300
Forward Current (mA)
400
500
600
0%
0
100
200
300
400
500
600
700
800
Forward Current (mA)
13
Performance Curves
Figure 15: Typical ccx Shift vs. Case Temperature
Figure 14: Typical DC Flux vs. Case Temperature
105%
0.0012
100%
0.0009
Neutral White
Cool White
0.0006
95%
ccx Shift
Relative Luminus Flux
Warm White
90%
Warm White
0.0003
0.0000
Neutral White
85%
-0.0003
Cool White
80%
0
25
50
75
-0.0006
100
0
Case Temperature(°C)
25
50
75
100
125
Case Temperature (°C)
Figure 16: Typical ccy Shift vs. Case Temperature
0
25
50
75
100
125
0.000
ccy Shift
-0.001
-0.002
-0.003
Warm White
-0.004
Neutral White
Cool White
-0.005
Case Temperature (°C)
Notes for Figures 14-16:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Characteristics shown for warm white based on 3000K Thrive
3. Characteristics shown for neutral white based on 4000K Thrive
4. Characteristics shown for cool white based on 5000K Thrive
5. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
14
Typical Radiation Pattern
Figure 17: Typical Spatial Radiation Pattern
Notes for Figure 17:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 18: Typical Polar Radiation Pattern
15
Mechanical Dimensions
Figure 19: V10 LED Array
Notes for Figure 19:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting locations (2X) are for M2.5 screws.
5. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
16
Packaging and Labeling
Figure 20: V10 Packaging
Notes for Figure 20:
1. Each tube holds 30 V10 COB arrays.
2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four
boxes may be used to ship products.
3. Each bag and box is to be labeled as shown above.
4. Dimensions for each tube are 8.3 (W) x 15.4 (H) x 430 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping
box are 58.7 x 13.3 x 7.9 cm
17
Packaging and Labeling
Figure 21: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30S1001C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
18
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the V Series
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux V Series LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN101 for additional information.
CAUTION: RISK OF BURN
Do not touch the V Series LED array during operation.
Allow the array to cool for a sufficient period of time
before handling. The V Series LED array may reach
elevated temperatures such that could burn skin when
touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area).
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered by
Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may
occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
19
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve
designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on
light’s impact on human behavior, delivering products that create better environments, experiences and returns—both
experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
linkedin.com/company/bridgelux-inc-_2
youtube.com/user/Bridgelux
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 USA
Tel (925) 583-8400
www.bridgelux.com
© 2019 Bridgelux, Inc. Product specifications are subject to change without notice. Bridgelux and the Bridgelux stylized logo design are registered trademarks of Bridgelux,
Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 V10 Thrive Array Product Data Sheet DS320 Rev. A (10/2019)
20