IM
EL
PR
®
Product Data Sheet DS321
RY
INA
Bridgelux Gen 7 V13 Thrive™ Array
1
| | | | | |
BXRE-27S 30S 35S 40S 50S 57S 65S
V13 Thrive
Introduction
Bridgelux Thrive™ combines unique chip, phosphor and packaging technology to closely match the spectra of natural
light over the visible wavelength range. Thrive can be used in constant color point luminaires to bring full spectrum
natural light indoors or in tunable white luminaires to incorporate circadian elements that may impact human well-being.
PR
The high fidelity spectral output of Thrive creates stunning environments with excellent color rendering and outstanding
TM30 metrics. Thrive is available in both SMD components and LED arrays to enable a broad range of lighting
applications including retail, hospitality, office, education, architectural, museums, healthcare and residential lighting.
EL
Features
Benefits
• Full consistent spectrum with fewer spectral spikes
• CRI >95, R1-R15 >90, high Rf and Rg values
• Natural and vivid color rendering
• High efficacy full spectrum solution
• Greater energy savings, lower utility costs
• No violet chip augmentation
• Economical, high efficiency solution
• Hot color targeted
• Uniform and consistent white light at application
conditions
IM
• Engineered spectrum to closely match natural light
• Form factor consistent with existing Bridgelux COB
arrays
• Broad product platform availability (SMDs and COBs)
• Ease of design and rapid go-to-market
• Enables greater design flexibility and platform color
consistency
RY
INA
Contents
2
Product Nomenclature
2
Product Selection Guide
3
Spectrum Characteristics
5
Electrical Characteristics
8
Absolute Maximum Ratings
9
PR
Product Feature Map
10
Product Bin Definitions
11
Performance Curves
12
Typical Radiation Pattern
14
Mechanical Dimensions
15
Packaging and Labeling
16
Design Resources
Precautions
Disclaimers
About Bridgelux
IM
EL
Eye Safety
18
18
18
19
RY
INA
1
Product Feature Map
Bridgelux arrays are fully engineered devices that provide consistent thermal and optical performance on an engineered
mechanical platform. The V Series arrays are the most compact chip-on-board devices across all of Bridgelux’s LED Array
products. The arrays incorporate several features to simplify design integration and assembly. Please visit www.bridgelux.com
for more information on the V Series family of products.
Polarity symbols
PR
White ring around LES
Fully engineered substrate
for consistent thermal, mechanical
and optical properties
EL
Case Temperature (Tc)
Measurement Point
Solder Pads
IM
Note: Part number and lot codes are scribed on back of array
Product Nomenclature
1 2 3 4
INA
The part number designation for Bridgelux COB arrays is explained as follows:
– 5 6 7 8 9 10 11
– 12
– 13 14
BXRE – 30 S 2001 – C –
7 3
Product Family
Gen 7
Array Configuration
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Flux Indicator
2001 = 2000 lm
Minimum CRI
S = Thrive
RY
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
CCT Bin Options
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tc= 25°C)
Minimum
Pulsed
Flux6,7,8
Tc = 25ºC
(lm)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
34.4
2330
2050
21.7
34.4
2520
2218
21.7
CRI
Typical Vf
(V)
2700
95
630
3000
95
630
95
BXRE-27S2001-C-73
BXRE-30S2001-C-73
3500
BXRE-35S2001-C-73
Typical
Pulsed
Flux4,5,6,7
Tc = 25ºC
(lm)
Nominal
Drive
Current3
(mA)
Nominal
CCT1
(K)
Part Number1,6
2
Typical
Photosynthetic
Photon Flux
(PPF)
Typical
Photon
Efficiency
(µmol/J)
108
43.28
2.00
116
43.65
2.01
34.4
2612
2299
21.7
121
43.80
2.02
4000
95
630
34.4
2661
2342
21.7
123
44.51
2.05
BXRE-50S2001-C-74
5000
95
630
34.4
2774
2441
21.7
128
45.80
2.11
BXRE-57S2001-C-74
5700
95
630
34.4
2810
2473
21.7
130
46.50
2.15
BXRE-65S2001-C-74
6500
95
630
34.4
2782
2448
21.7
128
46.55
2.15
PR
630
BXRE-40S2001-C-73
EL
Table 2: Selection Guide, Stabilized DC Test Performance (Tc= 85°C)4,5,6
CRI
Nominal
Drive
Current3
(mA)
Typical Vf
(V)
Typical DC
Flux4,5,6,7
Tc = 85ºC
(lm)
Minimum
DC
Flux6,7,8,9
Tc = 85ºC
(lm)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
Typical
Photosynthetic
Photon Flux
(PPF)
Typical
Photon
Efficiency
(µmol/J)
2700
95
630
33.7
2120
1866
21.2
100
40.12
1.89
BXRE-30S2001-C-73
3000
95
630
33.7
2293
2018
21.2
108
40.72
1.92
BXRE-35S2001-C-73
3500
95
630
33.7
2377
2092
21.2
112
40.80
1.92
BXRE-40S2001-C-73
4000
95
630
33.7
2421
2131
21.2
114
42.14
1.98
BXRE-50S2001-C-74
5000
95
630
33.7
2524
2221
21.2
119
43.21
2.04
BXRE-57S2001-C-74
5700
95
630
33.7
2557
2250
21.2
120
43.80
2.06
BXRE-65S2001-C-74
6500
95
630
33.7
2532
2228
21.2
119
44.23
2.08
Nominal
CCT1
(K)
BXRE-27S2001-C-73
Part Number
1,6
2
IM
RY
INA
Notes for Table 1 & 2:
1. Product CCT is hot targeted at Tj= 85°C. Nominal CCT as defined by ANSI C78.377-2011.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are minimums. Bridgelux maintains a ± 3 tolerance on CRI values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. Typical stabilized DC
performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
7. Bridgelux maintains a ±7% tolerance on flux measurements.
8. Minimum flux values at the nominal test current are guaranteed by 100% test.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup,
values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
3
Performance at Commonly Used Drive Currents
V Series Thrive LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. V Series
Thrive LED Arrays may also be driven at other drive currents dependent on specific application design requirements.
The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 10 &
11 and the flux vs. current characteristics shown in Figures 12 & 13. The performance at commonly used drive currents is
summarized in Table 3.
Table 3: Product Performance at Commonly Used Drive Currents
CRI
PR
Part Number
Drive
Current1
(mA)
BXRE-27S2001-C-73
95
BXRE-35S2001-C-73
BXRE-50S2001-C-73
95
95
1202
1117
14.1
1600
1464
113
630
34.4
21.7
2330
2120
108
100
945
35.2
33.3
3329
3017
1260
35.7
45.0
4332
3815
96
315
32.2
10.1
1301
1208
128
33.6
630
34.4
14.1
1730
1583
123
21.7
2520
2293
116
945
35.2
33.3
3601
3263
108
1260
35.7
45.0
4685
4126
104
315
32.2
10.1
1348
1252
133
420
33.6
14.1
1793
1641
127
630
34.4
21.7
2612
2377
121
945
35.2
33.3
3732
3382
112
1260
35.7
45.0
4857
4276
108
315
32.2
10.1
1373
1275
135
420
33.6
14.1
1827
1672
129
630
34.4
21.7
2661
2421
123
945
35.2
33.3
3802
3446
114
1260
35.7
45.0
4947
4356
110
315
32.2
10.1
1432
1329
141
420
33.6
14.1
1905
1743
135
630
34.4
21.7
2774
2524
128
420
630
945
1260
315
420
95
630
945
35.2
33.3
3964
3592
35.7
45.0
5158
4542
119
115
32.2
10.1
1450
1347
143
33.6
14.1
1929
1765
137
34.4
21.7
2810
2557
130
35.2
33.3
4015
3639
121
35.7
45.0
5224
4600
116
32.2
10.1
1436
1333
142
33.6
14.1
1910
1748
135
34.4
21.7
2782
2532
128
35.2
33.3
3975
3603
120
35.7
45.0
5173
4555
115
RY
1260
INA
315
BXRE-65S2001-C-73
119
10.1
1260
95
Typical
Efficacy
Tc = 25ºC
(lm/W)
32.2
945
BXRE-57S2001-C-73
Typical
DC Flux3
Tc = 85ºC
(lm)
33.6
IM
BXRE-40S2001-C-73
95
Typical
Flux2
Tc = 25ºC
(lm)
315
EL
95
Typical
Power
Tc = 25ºC
(W)
420
420
BXRE-30S2001-C-73
Typical Vf
Tc = 25ºC
(V)
Notes for Table 3:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
4
Spectrum Characteristics
Table 4: Typical Color Rendering Index and TM-30 Values at, Tc=85°C
Nominal
CCT1
Rf
Rg
R1
R2
R3
R4
R5
R6
R7
R8
R9
R10
R11
R12
R13
R14
R15
2700K
95
100
98
99
96
96
98
97
96
94
91
98
93
97
98
96
97
3000K
96
100
97
98
96
96
97
97
98
97
94
99
93
97
97
96
98
3500K
95
98
98
98
97
98
98
98
98
97
93
97
97
95
98
97
98
95
98
98
98
97
98
98
98
98
96
92
97
98
94
98
98
97
94
98
98
98
99
96
97
98
96
96
94
98
97
92
98
98
96
5700K
94
98
98
98
97
95
98
97
96
95
92
97
96
96
98
98
97
6500K
95
98
98
98
97
96
98
98
96
96
93
97
96
97
98
98
97
PR
4000K
5000K
Note for Table 4:
1. Bridgelux maintains a tolerance of ± 3 on Color Rendering Index R1-R15 measurements and TM-30 measurements.
Figure 1: 2700K Thrive TM-30 Graphs
IM
EL
Figure 2: 3000K Thrive TM-30 Graphs
RY
INA
Figure 3: 3500K Thrive TM-30 Graphs
5
Spectrum Characteristics
Figure 4: 4000K Thrive TM-30 Graphs
PR
Figure 5: 5000K Thrive TM-30 Graphs
IM
EL
Figure 6: 5700K Thrive TM30 Graphs
RY
INA
Figure 7: 6500K Thrive TM-30 Graphs
6
Spectrum Characteristics
Figure 8: Typical Color Spectrum
100%
100%
2700K
5000K
5700K
6500K
Relative Radiant Power(%)
80%
3500K
4000K
60%
PR
Relative Radiant Power(%)
3000K
40%
20%
0%
350
400
450
500
550
600
650
700
750
80%
60%
40%
20%
0%
800
350
400
450
500
Wavelength(nm)
550
600
650
700
750
800
Wavelength(nm)
EL
Note for Figure 8:
1. Color spectra measured at nominal current for Tj = 85°C.
4000K Spectral Comparison
120%
IM
100%
80%
60%
Thrive
40%
4000K BBC
90 CRI
20%
80 CRI
780
760
720
740
700
660
620
640
600
580
560
520
540
480
500
460
420
440
380
INA
400
0%
680
Relative Radiant Power (%)
140%
Wavelength (nm)
Spectral Matching to Natural Light
Humans have evolved and thrived for millions of years under the sun’s natural daylight. While discussions continue regarding the development of LED products with artificial spectra aimed at increasing productivity and focus or helping with relaxation, the long-term physiological effects of such altered environments on humans remains unknown.
Bridgelux Thrive is engineered to provide the closest match to natural light using proprietary chip, phosphor and packaging technology. Bridgelux is working
with our customers and industry partners to define new metrics to describe and quantify this spectral matching; going beyond today’s quality of light metrics
such as CRI and TM-30.
RY
To quantify spectral matching, Bridgelux has defined a new term; Average Spectral Difference (ASD). ASD is calculated by measuring the absolute difference
between the LED spectrum and a natural light source spectrum at discrete wavelengths. These values are then averaged across different wavelength ranges
and reported as a percentage. Natural light is defined by the Black Body Curve for sources below 5000K or by the CIE Standard Illuminant D for sources of
5000K or above (D50 for example).
Bridgelux Thrive has an ASD between 3% and 7% for all color points (2700K – 6500K) across the typical LED wavelength range of 440-650nm. This includes a
very close spectral match, with an ASD of only 2% for some color point options, in the blue/cyan color range where most other LED light sources suffer. For
comparison purposes, standard 80, 90 and 98 CRI light sources have an ASD that is 2-6 times larger than Thrive over the same wavelength range and up to 20
times greater in the cyan wavelength range.
As the industry evolves toward human centric lighting, Bridgelux will work with our customers and industry experts to educate the market about the benefits of
the ASD metric to further quantify the quality of light.
7
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRE-xxx2001-C-7x
Drive Current
(mA)
Maximum
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Minimum
Typical
630
32.2
34.4
37.4
-14.1
1260
33.4
35.7
38.8
-14.1
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.20
31.0
38.3
0.24
33.4
41.0
PR
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
EL
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working
voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
IM
RY
INA
8
Absolute Maximum Ratings
Table 6: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
PR
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
Maximum Drive Current3
1260mA
Maximum Peak Pulsed Drive Current4
1800mA
Maximum Reverse Voltage5
-60V
EL
Operating Case Temperature1 (Tc)
Notes for Table 6:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
IM
2. Refer to Bridgelux Application Note AN101: Handling and Assembly of Bridgelux V Series LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
RY
INA
9
Eye Safety
Table 7: Eye Safety Risk Group (RG) Classifications
Part Number
BXRE-xxx200x-C-7x
CCT1,5
2700K/3000K
4000K2
630
RG1
RG1
RG1
RG1
945
RG1
RG1
RG2
RG2
1260
RG1
RG2
RG2
RG2
PR
Drive
Current 5
(mA)
5000K3
6500K4
Notes for Table 7:
1. Eye safety classification for the use of Bridgelux V Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
IM
EL
RY
INA
10
Product Bin Definitions
Table 8: 2-, 3- and 4-step MacAdam Ellipse Color Bin Definitions
Center Point
Degree
2-step
3-step
4-step
CCT
y
Φ(°)
a
b
a
b
a
b
2700K
0.4578
0.4101
53.700
0.00540
0.00280
0.0081
0.0042
N/A
N/A
3000K
0.4338
0.403
53.217
0.00556
0.00272
0.0083
0.0041
N/A
N/A
4000K
0.3818
0.3797
53.717
0.00626
0.00268
0.0094
0.0040
N/A
N/A
5000K
0.3447
0.3553
59.617
N/A
N/A
0.0082
0.0035
0.0110
0.0047
5700K
0.3287
0.3417
59.060
N/A
N/A
0.0074
0.0032
0.0099
0.0042
N/A
0.0066
0.0028
0.0090
0.0038
EL
PR
x
0.3123
6500K
0.3282
58.567
N/A
Notes for Table 8:
1. Color binning at Tc=85°C
2. Bridgelux maintains a tolerance of ± 0.007 on x and y color coordinates in the CIE 1931 color space.
IM
Figure 9: C.I.E. 1931 Chromaticity Diagram (Color targeted at Tc=85°C)
0.44
0.39
3 SDCM
4 SDCM
2 SDCM
0.38
2700K
0.42
3 SDCM
3000K
0.37
5000K
INA
3500K
0.36
0.4
5700K
0.35
Y
Y
4000K
0.38
6500K
0.34
0.33
0.36
0.32
0.34
0.36
0.31
0.39
0.42
0.45
X
0.48
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
X
RY
11
Performance Curves
Figure 10: V13C Drive Current vs. Voltage (Tc=25°C)
Figure 11: V13C Typical Relative Flux vs. Current (Tc=25°C)
1800
250%
1600
200%
1400
Relative Flux
Current (mA)
1200
1000
800
150%
100%
600
50%
PR
400
200
0
32
33
34
35
0%
36
37
38
39
0
500
Forward Voltage (V)
95%
90%
warm white
neutral white
85%
cool white
80%
0
20
0.0030
0
25
40
60
50
Cool White
0.0010
0.0000
80
100
120
-0.0020
Tj (°C)
Notes for Figures 12-14:
100
125
1. Bridgelux does not recommend driving high power LEDs at low currents.
Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
3. Characteristics shown for neutral white based on 4000K Thrive
4. Characteristics shown for cool white based on 5700K Thrive
5. For other color SKUs, the shift in color will vary. Please contact your Bridgelux
Sales Representative for more information.
Warm White
Neutral White
Cool White
-0.005
Tj (°C)
RY
ccy Shift
75
2. Characteristics shown for warm white based on 3000K Thrive
-0.002
-0.004
100
INA
25
-0.001
-0.003
75
-0.0010
Figure 14: Typical ccy Shift vs. Case Temperature
0.000
50
Neutral White
Tj (°C)
0
2000
Warm White
0.0020
IM
Relative Flux
100%
EL
105%
1500
Figure 13: Typical ccx Shift vs. Case Temperature
ccx Shift
Figure 12: Typical DC Flux vs. Case Temperature
1000
Current (mA)
12
Typical Radiation Pattern
Figure 15: Typical Spatial Radiation Pattern
EL
PR
Notes for Figure 15:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
IM
Figure 16: Typical Polar Radiation Pattern
RY
INA
13
Mechanical Dimensions
Figure 17: V13 LED Array
EL
PR
Notes for Figure 17:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting locations (2X) are for M2.5 screws.
IM
5. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
6. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
7. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
RY
INA
14
Packaging and Labeling
Figure 18: V13 Packaging
IM
EL
PR
1. Each tube holds 30 V13 COB arrays.
RY
INA
Notes for Figure 18:
2. One tube is sealed in an anti-static bag. Four bags are placed in a shipping box. Depending on quantities ordered, a bigger shipping box, containing four
boxes may be used to ship products.
3. Each bag and box is to be labeled as shown above.
4. Dimensions for each tube are 8.3 (W) x 15.4 (H) x 430 (L). Dimensions for the anti-static bag are 75 (W) x 615 (L) x 3.1 (T) mm. Dimensions for the shipping
box are 58.7 x 13.3 x 7.9 cm
15
Packaging and Labeling
Figure 19: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
PR
Customer Use- Product part number
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
30S2001C 73 2F
IM
EL
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
RY
INA
16
Design Resources
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the V Series
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux V Series LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
PR
Application Notes
Precautions
EL
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN101 for additional information.
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
IM
CAUTION: RISK OF BURN
CAUTION
Disclaimers
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area).
RY
INA
Do not touch the V Series LED array during operation.
Allow the array to cool for a sufficient period of time
before handling. The V Series LED array may reach
elevated temperatures such that could burn skin when
touched.
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered by
Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may
occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
17
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve
designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on
light’s impact on human behavior, delivering products that create better environments, experiences and returns—both
experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires.
PR
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
linkedin.com/company/bridgelux-inc-_2
youtube.com/user/Bridgelux
WeChat ID: BridgeluxInChina
IM
EL
Fremont, CA 94538 USA
Tel (925) 583-8400
www.bridgelux.com
RY
INA
46430 Fremont Boulevard
© 2019 Bridgelux, Inc. Product specifications are subject to change without notice. Bridgelux and the Bridgelux stylized logo design are registered trademarks of Bridgelux,
Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 V13 Thrive Array Preliminary Product Data Sheet DS321 Rev. A (11/2019)
18