CFM40D/T SERIES
40W DUAL/TRIPLE OUTPUT
AC-DC MODULES
Features
⚫ Universal Input Range 90~264Vac
⚫ Efficiency to 81%
⚫ 2”x 4” Size
⚫ Meets Class I
⚫ Approval IEC/EN/UL 62368-1
⚫ Approval EN 61204-3 Class B
and CISPR/FCC Class B
⚫ Continuous Short Circuit Protection
MODEL
OUTPUT
NUMBER
VOLTAGE
CFM40D-01
OUTPUT
VOLTAGE
CURRENT
ACCURACY
NOISE
NOTE1
NOTE2
NOTE3
NOTE4
±3%
±4%
±3%
±4%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
±3%
±4%
±3%
50 mV
120 mV
50 mV
240 mV
50 mV
120 mV
50 mV
50 mV
120 mV
120 mV
50 mV
150 mV
150 mV
50 mV
240 mV
120 mV
50 mV
240 mV
50 mV
50 mV
240 mV
120 mV
100 mV
100 mV
120 mV
±1%
±2%
±1%
±2%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±2%
±1%
±1%
±3%
±1%
±3%
±5%
±3%
±5%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
±3%
±5%
±1%
Min.
Rated Max.
5 V(V1)
12 V(V2)
0.4 A
0.2 A
3.2 A
2.0 A
5.0 A
2.5 A
CFM40D-02
5 V(V1)
24 V(V2)
0.4 A
0.2 A
3.2 A
1.0 A
5.0 A
1.5 A
CFM40T-01
5 V(V1)
12 V(V2)
-5 V(V3)
0.4 A
0.2 A
0A
3.0 A
2.0 A
0.3 A
5.0 A
2.5 A
0.5 A
CFM40T-02
5 V(V1)
12 V(V2)
-12 V(V3)
0.4 A
0.2 A
0A
3.0 A
2.0 A
0.3 A
5.0 A
2.5 A
0.5 A
CFM40T-03
5 V(V1)
15 V(V2)
-15 V(V3)
0.4 A
0.2 A
0A
3.0 A
1.5 A
0.3 A
5.0 A
2.3 A
0.5 A
CFM40T-04
5 V(V1)
24 V(V2)
-12 V(V3)
0.4 A
0.2 A
0A
3.0 A
1.0 A
0.3 A
5.0 A
1.5 A
0.5 A
CFM40T-05
5 V(V1)
24 V(V2)
-5 V(V3)
0.4 A
0.2 A
0A
3.0 A
1.0 A
0.3 A
5.0 A
1.5 A
0.5 A
CFM40T-06
5 V(V1)
24 V(V2)
12 V(V3)
0.4 A
0.2 A
0A
3.0 A
1.0 A
0.3 A
5.0 A
1.5 A
0.5 A
CFM40T-07
3.3 V(V1)
5 V(V2)
-12 V(V3)
0.4 A
0.2 A
0A
5.0 A
2.0 A
0.3 A
7.0 A
3.5 A
0.5 A
RIPPLE&
LINE
LOAD
O/P
REGULATION REGULATION POWER
%EFF.
(Typ.)
Max.
NOTE5
40.0W
80%
40.0W
81%
40.5W
78%
42.6W
78%
42.0W
78%
42.6W
78%
40.5W
78%
42.6W
78%
30.0W
71%
Note:
1. Voltage accuracy is set at rated load and 25℃ Ta.
2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring @20MHz B.W.
3. Line regulation is measured from 100Vac to 240Vac with rated load.
4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at other outputs set to 60% rated load.
5. Typical efficiency at 230 Vac and rated load at 25℃.
6. Safety approvals do not apply to the covered versions, only to the open-frame versions.
www.cincon.com
1
REVISION: V15
CFM40D/T
Series
PART NUMBER
Series
CFM40
Number of Outputs
D/T
D:Double Output
CFM40
T:Triple Output
Nominal Output Voltage
-XX
V1:5V
01:
V2:12V
V1:5V
02:
V2:24V
V1:5V
01:V2:12V
V3:-5V
V1:5V
02:V2:12V
V3:-12V
V1:5V
03:V2:15V
V3:-15V
V1:5V
04:V2:24V
V3:-12V
V1:5V
05:V2:24V
V3:-5V
V1:5V
06:V2:24V
V3:12V
V1:3.3V
07:V2:5V
V3:-12V
Type
-X (Option)
None:Wafer
CA:Cover
Part Number Example:
CFM40D-01: Open Frame Type, 40W, Double Output V1:5V, V2:12V
CFM40T-01-CA: Cover Type, 40W, Triple Output V1:5V, V2:12V, V3:-5V
www.cincon.com
2
REVISION: V15
CFM40D/T
Series
TECHNICAL SPECIFICATIONS
(All specifications are typical at nominal input, 100% full load at 25℃ unless otherwise noted.)
ABSOLUTE MAXIMUM RATINGS
PARAMETER
NOTES and CONDITIONS
Device
Input Voltage
Safety approvals only to the AC
input
All
Operating Temperature
See Derating Curve
Min.
Typ.
Max.
Units
90
264
Vac
120
370
Vdc
All
0
70
℃
Storage Temperature
All
-20
85
℃
Operating Altitude
All
2000
m
Max.
Units
INPUT CHARACTERISTICS
PARAMETER
Device
Min.
Operating Voltage Range
All
100
240
Vac
Input Frequency Range
All
47
63
Hz
All
1
A
All
3.5
mA
All
60
A
Max.
Units
Maximum Input Current
NOTES and CONDITIONS
100% full load, Vin=100Vac
Leakage Current
Inrush Current
Vin=240Vac, Cold start at 25℃
Typ.
OUTPUT CHARACTERISTICS
PARAMETER
NOTES and CONDITIONS
Device
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
CFM40T-03
Output Voltage Set Point
Vin=Nominal Vin, Io=Io rated, Tc=25℃
CFM40T-04
CFM40T-05
CFM40T-06
CFM40T-07
www.cincon.com
3
Min.
Typ.
V1
4.85
5.0
5.15
V2
11.52
12.0
12.48
V1
4.85
5.0
5.15
V2
23.04
24.0
24.96
V1
4.85
5.0
5.15
V2
11.52
12.0
12.48
V3
-5.15
-5.0
-4.85
V1
4.85
5.0
5.15
V2
11.52
12.0
12.48
V3
-12.36
-12.0
-11.64
V1
4.85
5.0
5.15
V2
14.4
15.0
15.6
V3
-15.45
-15.0
-14.55
V1
4.85
5.0
5.15
V2
23.04
24.0
24.96
V3
-12.36
-12.0
-11.64
V1
4.85
5.0
5.15
V2
23.04
24.0
24.96
V3
-5.15
-5.0
-4.85
V1
4.85
5.0
5.15
V2
23.04
24.0
24.96
V3
11.64
12.0
12.36
V1
3.2
3.3
3.4
V2
4.8
5.0
5.2
V3
-12.36
-12.0
-11.64
Vdc
REVISION: V15
CFM40D/T
PARAMETER
NOTES and CONDITIONS
Device
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
Operating Output Current Range
Vin=90Vac~264Vac , See Derating
Curve
CFM40T-03
CFM40T-04
CFM40T-05
CFM40T-06
CFM40T-07
Holdup Time
Vin=115Vac
Series
Min.
Typ.
Max.
V1
0.4
3.2
5.0
V2
0.2
2.0
2.5
V1
0.4
3.2
5.0
V2
0.2
1.0
1.5
V1
0.4
3.0
5.0
V2
0.2
2.0
2.5
V3
0
0.3
0.5
V1
0.4
3.0
5.0
V2
0.2
2.0
2.5
V3
0
0.3
0.5
V1
0.4
3.0
5.0
V2
0.2
1.5
2.3
V3
0
0.3
0.5
V1
0.4
3.0
5.0
V2
0.2
1.0
1.5
V3
0
0.3
0.5
V1
0.4
3.0
5.0
V2
0.2
1.0
1.5
V3
0
0.3
0.5
V1
0.4
3.0
5.0
V2
0.2
1.0
1.5
V3
0
0.3
0.5
V1
0.4
5.0
7.0
V2
0.2
2.0
3.5
V3
0
0.3
0.5
All
Units
A
ms
20
Output Voltage Regulation
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
Load Regulation
Defined by changing ±40% of
measured output load from 60%
rated load at other output set to 60%
rated load
CFM40T-03
CFM40T-04
CFM40T-05
CFM40T-06
www.cincon.com
4
V1
±3
V2
±5
V1
±3
V2
±5
V1
±3
V2
±5
V3
±1
V1
±3
V2
±5
V3
±1
V1
±3
V2
±5
V3
±1
V1
±3
V2
±5
V3
±1
V1
±3
V2
±5
V3
±1
V1
±3
V2
±5
V3
±1
%
REVISION: V15
CFM40D/T
PARAMETER
NOTES and CONDITIONS
Load Regulation
Defined by changing ±40% of
measured output load from 60%
rated load at other output set to 60%
rated load.
Device
CFM40T-07
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
CFM40T-03
Line Regulation
Vin=100Vac to 240Vac
CFM40T-04
CFM40T-05
CFM40T-06
CFM40T-07
Min.
Hiccup mode (auto recovery)
All
Short Circuit Protection
Hiccup mode (auto recovery)
All
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
Over Voltage Protection
Hiccup mode (Auto recovery)
CFM40T-03
CFM40T-04
CFM40T-05
CFM40T-06
CFM40T-07
www.cincon.com
5
Max.
V1
±3
V2
±5
V3
±1
V1
±1
V2
±2
V1
±1
V2
±2
V1
±1
V2
±2
V3
±1
V1
±1
V2
±2
V3
±1
V1
±1
V2
±2
V3
±1
V1
±1
V2
±2
V3
±1
V1
±1
V2
±2
V3
±1
V1
±1
V2
±2
V3
±1
V1
±1
V2
±3
V3
Over Current Protection
Typ.
Series
Units
%
%
±1
110
180
V1
6
V2
16
V1
6
V2
30
V1
6
V2
16
V1
6
V2
16
V1
6
V2
20
V1
6
V2
30
V1
6
V2
30
V1
6
V2
30
V1
6
V2
9
%
Vdc
REVISION: V15
CFM40D/T
PARAMETER
NOTES and CONDITIONS
Device
CFM40D-01
CFM40D-02
CFM40T-01
CFM40T-02
Output Ripple and Noise
1. Add a 0.1uF ceramic capacitor
and a 10uF aluminum electrolytic
capacitor to output
2. Oscilloscope is 20MHz bandwidth
3. Ambient temperature=25℃
CFM40T-03
CFM40T-04
CFM40T-05
CFM40T-06
CFM40T-07
Min.
Typ.
Efficiency
Max.
V1
50
V2
120
V1
50
V2
240
V1
50
V2
120
V3
50
V1
50
V2
120
V3
120
V1
50
V2
150
V3
150
V1
50
V2
240
V3
120
V1
50
V2
240
V3
50
V1
50
V2
240
V3
120
V1
100
V2
100
V3
1. Vin=230Vac
2. Output is 100% full load
3. Ambient temperature=25℃
Series
Units
mV
120
CFM40D-01
80
CFM40D-02
81
CFM40T-01
78
CFM40T-02
78
CFM40T-03
78
CFM40T-04
78
CFM40T-05
78
CFM40T-06
78
CFM40T-07
71
%
ISOLATION CHARACTERISTICS
PARAMETER
NOTES and CONDITIONS
Device
Min.
Input to Output
1 Minute
All
Isolation Resistance
Input to output
All
100
Device
Min.
Typ.
Max.
4242
Units
Vdc
MΩ
FEATURE CHARACTERISTICS
PARAMETER
NOTES and CONDITIONS
Switching Frequency
Pout=max. rated power
All
Typ.
Max.
65
Units
kHz
GENERAL SPECIFICATIONS
PARAMETER
MTBF
Humidity
www.cincon.com
NOTES and CONDITIONS
Io=100%; Ta=25℃ per MIL-HDBK-217F
I o=100%; Ta=25℃ Telcordia SR332
Non-condensing
Device
All
All
6
Min.
Typ.
Max.
280
Units
k
hours
2700
93
% RH
REVISION: V15
CFM40D/T
Series
GENERAL SPECIFICATIONS
PARAMETER
NOTES and CONDITIONS
Device
Meet MIL-STD-810F Table
516.5,Table 516.5-I 10ms, each axis
3 times(±X、±Y、±Z axis)
Meet MIL-STD-810F Table 514.5CVIII,15~2000Hz, X、Y、Z axis, 1
hour (each axis),. Total 3 hrs.
Open frame versions
Shock
Vibration
Weight
Typ.
Max.
Units
All
75
g
All
4
g
All
160
grams
Covered versions
220
4.000x2.000x1.224 Inches
(101.60x50.80x31.10 mm)
4.606x2.480x1.575 Inches
(117.00x63.00x40.00 mm)
Open frame (Wafer)
Dimensions
CA (Cover)
Safety
Min.
Conducted Disturbance
Class I, IEC/EN/UL 62368-1
EN 61204-3:2000, Class B, FCC Part 15 Subpart B
EN 61000-3-2:2014, EN 61000-3-3:2013
EN 61204-3:2000, FCC Part 15 Subpart B
Class B
Radiated Disturbance
EN 61204-3:2000, FCC Part 15 Subpart B
Class B
Harmonic Current Emissions
EN 61000-3-2:2014
Class A
Voltage Fluctuations & Flicker
EN 61000-3-3:2013
EMC Immunity
EN 61204-3:2020, IEC 61000-4-2, 3, 4, 5, 6, 11
Electrostatic Discharge (ESD)
Radio-Frequency, Continuous
Radiated Disturbance
Electrical Fast Transient (EFT)
IEC 61000-4-2:2008, Air Discharge: ±8kV Contact, Discharge: ±4kV
Criterion A
IEC 61000-4-3:2010
Criterion A
IEC 61000-4-4:2012, ±1kV
Criterion A
Surge
Conducted Disturbances,
Induced by RF Fields
Voltage Dips
IEC 61000-4-5:2014, L-N: ±1kV
Criterion A
IEC 61000-4-6:2013
Criterion A
IEC 61000-4-11:2004, Dips: 30% Reduction, Dips: >95% Reduction
Criterion A
Voltage Interruptions
IEC 61000-4-11:2004, >95% Reduction
EMC Emission
Application Note Link
Ed.3.0
Criterion B
CFM40D/T Series App Notes
CHARACTERISTIC CURVE
Power Derating Curve
Open Frame versions
CFM40D/T Series
Rate Load (%)
100%
75%
50%
20 LFM(Natural Convection)
25%
0%
0
10
20
30
40
50
60
70
Ambient Temperature(℃)
www.cincon.com
7
REVISION: V15
CFM40D/T
Covered versions:
CFM40T-07-CA
CFM40D-01/02,CFM40T-01/02/03/04/05/06-CA
80%
80%
Rate Load (%)
100%
Rate Load (%)
100%
60%
40%
20 LFM(Natural Convection)
20%
Series
0%
60%
40%
20 LFM(Natural Convection)
20%
0%
0
10
20
30
40
50
60
0
10
Ambient Temperature(℃)
20
30
40
50
60
Ambient Temperature(℃)
Performance Data
CFM40D-02 (Eff Vs Io)
90%
85%
85%
Efficiency (%)
Efficiency (%)
CFM40D-01 (Eff Vs Io)
90%
80%
75%
115V
70%
65%
10%
230V
20%
30%
40%
50%
60%
70%
80%
80%
75%
65%
10%
90% 100%
115V
70%
230V
20%
30%
Current Load (%)
85%
85%
80%
75%
115V
70%
230V
30%
40%
50%
60%
70%
80%
90% 100%
Current Load (%)
www.cincon.com
60%
70%
80%
90% 100%
CFM40T-02 (Eff Vs Io)
90%
Efficiency (%)
Efficiency (%)
CFM40T-01 (Eff Vs Io)
20%
50%
Current Load (%)
90%
65%
10%
40%
80%
75%
115V
70%
65%
10%
230V
20%
30%
40%
50%
60%
70%
80%
90% 100%
Current Load (%)
8
REVISION: V15
CFM40D/T
CFM40T-04 (Eff Vs Io)
90%
90%
85%
85%
Efficiency (%)
Efficiency (%)
CFM40T-03 (Eff Vs Io)
80%
75%
115V
70%
65%
10%
230V
20%
30%
40%
50%
60%
70%
80%
80%
75%
70%
65%
10%
90% 100%
115V
230V
20%
30%
Current Load (%)
85%
85%
80%
75%
115V
70%
230V
30%
40%
50%
60%
70%
50%
60%
70%
80%
90% 100%
CFM40T-06 (Eff Vs Io)
90%
Efficiency (%)
Efficiency (%)
CFM40T-05 (Eff Vs Io)
20%
40%
Current Load (%)
90%
65%
10%
Series
80%
90% 100%
Current Load (%)
80%
75%
115V
70%
65%
10%
230V
20%
30%
40%
50%
60%
70%
80%
90% 100%
Current Load (%)
CFM40T-07 (Eff Vs Io)
80%
Efficiency (%)
75%
70%
65%
115V
60%
55%
10%
230V
20%
30%
40%
50%
60%
70%
80%
90% 100%
Current Load (%)
www.cincon.com
9
REVISION: V15
CFM40D/T
Series
MECHANICAL SPECIFICATION
CFM40D/T Open Frame
CFM40D/T with Cover
sales@cincon.com
www.cincon.com
10
REVISION: V15