0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
CFM40T-03

CFM40T-03

  • 厂商:

    CINCON

  • 封装:

  • 描述:

    开放框架 AC DC 转换器 3 输出 5V 15V -15V 90 ~ 264 VAC 输入

  • 数据手册
  • 价格&库存
CFM40T-03 数据手册
CFM40D/T SERIES 40W DUAL/TRIPLE OUTPUT AC-DC MODULES Features ⚫ Universal Input Range 90~264Vac ⚫ Efficiency to 81% ⚫ 2”x 4” Size ⚫ Meets Class I ⚫ Approval IEC/EN/UL 62368-1 ⚫ Approval EN 61204-3 Class B and CISPR/FCC Class B ⚫ Continuous Short Circuit Protection MODEL OUTPUT NUMBER VOLTAGE CFM40D-01 OUTPUT VOLTAGE CURRENT ACCURACY NOISE NOTE1 NOTE2 NOTE3 NOTE4 ±3% ±4% ±3% ±4% ±3% ±4% ±3% ±3% ±4% ±3% ±3% ±4% ±3% ±3% ±4% ±3% ±3% ±4% ±3% ±3% ±4% ±3% ±3% ±4% ±3% 50 mV 120 mV 50 mV 240 mV 50 mV 120 mV 50 mV 50 mV 120 mV 120 mV 50 mV 150 mV 150 mV 50 mV 240 mV 120 mV 50 mV 240 mV 50 mV 50 mV 240 mV 120 mV 100 mV 100 mV 120 mV ±1% ±2% ±1% ±2% ±1% ±2% ±1% ±1% ±2% ±1% ±1% ±2% ±1% ±1% ±2% ±1% ±1% ±2% ±1% ±1% ±2% ±1% ±1% ±3% ±1% ±3% ±5% ±3% ±5% ±3% ±5% ±1% ±3% ±5% ±1% ±3% ±5% ±1% ±3% ±5% ±1% ±3% ±5% ±1% ±3% ±5% ±1% ±3% ±5% ±1% Min. Rated Max. 5 V(V1) 12 V(V2) 0.4 A 0.2 A 3.2 A 2.0 A 5.0 A 2.5 A CFM40D-02 5 V(V1) 24 V(V2) 0.4 A 0.2 A 3.2 A 1.0 A 5.0 A 1.5 A CFM40T-01 5 V(V1) 12 V(V2) -5 V(V3) 0.4 A 0.2 A 0A 3.0 A 2.0 A 0.3 A 5.0 A 2.5 A 0.5 A CFM40T-02 5 V(V1) 12 V(V2) -12 V(V3) 0.4 A 0.2 A 0A 3.0 A 2.0 A 0.3 A 5.0 A 2.5 A 0.5 A CFM40T-03 5 V(V1) 15 V(V2) -15 V(V3) 0.4 A 0.2 A 0A 3.0 A 1.5 A 0.3 A 5.0 A 2.3 A 0.5 A CFM40T-04 5 V(V1) 24 V(V2) -12 V(V3) 0.4 A 0.2 A 0A 3.0 A 1.0 A 0.3 A 5.0 A 1.5 A 0.5 A CFM40T-05 5 V(V1) 24 V(V2) -5 V(V3) 0.4 A 0.2 A 0A 3.0 A 1.0 A 0.3 A 5.0 A 1.5 A 0.5 A CFM40T-06 5 V(V1) 24 V(V2) 12 V(V3) 0.4 A 0.2 A 0A 3.0 A 1.0 A 0.3 A 5.0 A 1.5 A 0.5 A CFM40T-07 3.3 V(V1) 5 V(V2) -12 V(V3) 0.4 A 0.2 A 0A 5.0 A 2.0 A 0.3 A 7.0 A 3.5 A 0.5 A RIPPLE& LINE LOAD O/P REGULATION REGULATION POWER %EFF. (Typ.) Max. NOTE5 40.0W 80% 40.0W 81% 40.5W 78% 42.6W 78% 42.0W 78% 42.6W 78% 40.5W 78% 42.6W 78% 30.0W 71% Note: 1. Voltage accuracy is set at rated load and 25℃ Ta. 2. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for ripple & noise measuring @20MHz B.W. 3. Line regulation is measured from 100Vac to 240Vac with rated load. 4. Load regulation is defined by changing ±40% of measured output load from 60% rated load at other outputs set to 60% rated load. 5. Typical efficiency at 230 Vac and rated load at 25℃. 6. Safety approvals do not apply to the covered versions, only to the open-frame versions. www.cincon.com 1 REVISION: V15 CFM40D/T Series PART NUMBER Series CFM40 Number of Outputs D/T D:Double Output CFM40 T:Triple Output Nominal Output Voltage -XX V1:5V 01: V2:12V V1:5V 02: V2:24V V1:5V 01:V2:12V V3:-5V V1:5V 02:V2:12V V3:-12V V1:5V 03:V2:15V V3:-15V V1:5V 04:V2:24V V3:-12V V1:5V 05:V2:24V V3:-5V V1:5V 06:V2:24V V3:12V V1:3.3V 07:V2:5V V3:-12V Type -X (Option) None:Wafer CA:Cover Part Number Example: CFM40D-01: Open Frame Type, 40W, Double Output V1:5V, V2:12V CFM40T-01-CA: Cover Type, 40W, Triple Output V1:5V, V2:12V, V3:-5V www.cincon.com 2 REVISION: V15 CFM40D/T Series TECHNICAL SPECIFICATIONS (All specifications are typical at nominal input, 100% full load at 25℃ unless otherwise noted.) ABSOLUTE MAXIMUM RATINGS PARAMETER NOTES and CONDITIONS Device Input Voltage Safety approvals only to the AC input All Operating Temperature See Derating Curve Min. Typ. Max. Units 90 264 Vac 120 370 Vdc All 0 70 ℃ Storage Temperature All -20 85 ℃ Operating Altitude All 2000 m Max. Units INPUT CHARACTERISTICS PARAMETER Device Min. Operating Voltage Range All 100 240 Vac Input Frequency Range All 47 63 Hz All 1 A All 3.5 mA All 60 A Max. Units Maximum Input Current NOTES and CONDITIONS 100% full load, Vin=100Vac Leakage Current Inrush Current Vin=240Vac, Cold start at 25℃ Typ. OUTPUT CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 CFM40T-03 Output Voltage Set Point Vin=Nominal Vin, Io=Io rated, Tc=25℃ CFM40T-04 CFM40T-05 CFM40T-06 CFM40T-07 www.cincon.com 3 Min. Typ. V1 4.85 5.0 5.15 V2 11.52 12.0 12.48 V1 4.85 5.0 5.15 V2 23.04 24.0 24.96 V1 4.85 5.0 5.15 V2 11.52 12.0 12.48 V3 -5.15 -5.0 -4.85 V1 4.85 5.0 5.15 V2 11.52 12.0 12.48 V3 -12.36 -12.0 -11.64 V1 4.85 5.0 5.15 V2 14.4 15.0 15.6 V3 -15.45 -15.0 -14.55 V1 4.85 5.0 5.15 V2 23.04 24.0 24.96 V3 -12.36 -12.0 -11.64 V1 4.85 5.0 5.15 V2 23.04 24.0 24.96 V3 -5.15 -5.0 -4.85 V1 4.85 5.0 5.15 V2 23.04 24.0 24.96 V3 11.64 12.0 12.36 V1 3.2 3.3 3.4 V2 4.8 5.0 5.2 V3 -12.36 -12.0 -11.64 Vdc REVISION: V15 CFM40D/T PARAMETER NOTES and CONDITIONS Device CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 Operating Output Current Range Vin=90Vac~264Vac , See Derating Curve CFM40T-03 CFM40T-04 CFM40T-05 CFM40T-06 CFM40T-07 Holdup Time Vin=115Vac Series Min. Typ. Max. V1 0.4 3.2 5.0 V2 0.2 2.0 2.5 V1 0.4 3.2 5.0 V2 0.2 1.0 1.5 V1 0.4 3.0 5.0 V2 0.2 2.0 2.5 V3 0 0.3 0.5 V1 0.4 3.0 5.0 V2 0.2 2.0 2.5 V3 0 0.3 0.5 V1 0.4 3.0 5.0 V2 0.2 1.5 2.3 V3 0 0.3 0.5 V1 0.4 3.0 5.0 V2 0.2 1.0 1.5 V3 0 0.3 0.5 V1 0.4 3.0 5.0 V2 0.2 1.0 1.5 V3 0 0.3 0.5 V1 0.4 3.0 5.0 V2 0.2 1.0 1.5 V3 0 0.3 0.5 V1 0.4 5.0 7.0 V2 0.2 2.0 3.5 V3 0 0.3 0.5 All Units A ms 20 Output Voltage Regulation CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 Load Regulation Defined by changing ±40% of measured output load from 60% rated load at other output set to 60% rated load CFM40T-03 CFM40T-04 CFM40T-05 CFM40T-06 www.cincon.com 4 V1 ±3 V2 ±5 V1 ±3 V2 ±5 V1 ±3 V2 ±5 V3 ±1 V1 ±3 V2 ±5 V3 ±1 V1 ±3 V2 ±5 V3 ±1 V1 ±3 V2 ±5 V3 ±1 V1 ±3 V2 ±5 V3 ±1 V1 ±3 V2 ±5 V3 ±1 % REVISION: V15 CFM40D/T PARAMETER NOTES and CONDITIONS Load Regulation Defined by changing ±40% of measured output load from 60% rated load at other output set to 60% rated load. Device CFM40T-07 CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 CFM40T-03 Line Regulation Vin=100Vac to 240Vac CFM40T-04 CFM40T-05 CFM40T-06 CFM40T-07 Min. Hiccup mode (auto recovery) All Short Circuit Protection Hiccup mode (auto recovery) All CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 Over Voltage Protection Hiccup mode (Auto recovery) CFM40T-03 CFM40T-04 CFM40T-05 CFM40T-06 CFM40T-07 www.cincon.com 5 Max. V1 ±3 V2 ±5 V3 ±1 V1 ±1 V2 ±2 V1 ±1 V2 ±2 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±2 V3 ±1 V1 ±1 V2 ±3 V3 Over Current Protection Typ. Series Units % % ±1 110 180 V1 6 V2 16 V1 6 V2 30 V1 6 V2 16 V1 6 V2 16 V1 6 V2 20 V1 6 V2 30 V1 6 V2 30 V1 6 V2 30 V1 6 V2 9 % Vdc REVISION: V15 CFM40D/T PARAMETER NOTES and CONDITIONS Device CFM40D-01 CFM40D-02 CFM40T-01 CFM40T-02 Output Ripple and Noise 1. Add a 0.1uF ceramic capacitor and a 10uF aluminum electrolytic capacitor to output 2. Oscilloscope is 20MHz bandwidth 3. Ambient temperature=25℃ CFM40T-03 CFM40T-04 CFM40T-05 CFM40T-06 CFM40T-07 Min. Typ. Efficiency Max. V1 50 V2 120 V1 50 V2 240 V1 50 V2 120 V3 50 V1 50 V2 120 V3 120 V1 50 V2 150 V3 150 V1 50 V2 240 V3 120 V1 50 V2 240 V3 50 V1 50 V2 240 V3 120 V1 100 V2 100 V3 1. Vin=230Vac 2. Output is 100% full load 3. Ambient temperature=25℃ Series Units mV 120 CFM40D-01 80 CFM40D-02 81 CFM40T-01 78 CFM40T-02 78 CFM40T-03 78 CFM40T-04 78 CFM40T-05 78 CFM40T-06 78 CFM40T-07 71 % ISOLATION CHARACTERISTICS PARAMETER NOTES and CONDITIONS Device Min. Input to Output 1 Minute All Isolation Resistance Input to output All 100 Device Min. Typ. Max. 4242 Units Vdc MΩ FEATURE CHARACTERISTICS PARAMETER NOTES and CONDITIONS Switching Frequency Pout=max. rated power All Typ. Max. 65 Units kHz GENERAL SPECIFICATIONS PARAMETER MTBF Humidity www.cincon.com NOTES and CONDITIONS Io=100%; Ta=25℃ per MIL-HDBK-217F I o=100%; Ta=25℃ Telcordia SR332 Non-condensing Device All All 6 Min. Typ. Max. 280 Units k hours 2700 93 % RH REVISION: V15 CFM40D/T Series GENERAL SPECIFICATIONS PARAMETER NOTES and CONDITIONS Device Meet MIL-STD-810F Table 516.5,Table 516.5-I 10ms, each axis 3 times(±X、±Y、±Z axis) Meet MIL-STD-810F Table 514.5CVIII,15~2000Hz, X、Y、Z axis, 1 hour (each axis),. Total 3 hrs. Open frame versions Shock Vibration Weight Typ. Max. Units All 75 g All 4 g All 160 grams Covered versions 220 4.000x2.000x1.224 Inches (101.60x50.80x31.10 mm) 4.606x2.480x1.575 Inches (117.00x63.00x40.00 mm) Open frame (Wafer) Dimensions CA (Cover) Safety Min. Conducted Disturbance Class I, IEC/EN/UL 62368-1 EN 61204-3:2000, Class B, FCC Part 15 Subpart B EN 61000-3-2:2014, EN 61000-3-3:2013 EN 61204-3:2000, FCC Part 15 Subpart B Class B Radiated Disturbance EN 61204-3:2000, FCC Part 15 Subpart B Class B Harmonic Current Emissions EN 61000-3-2:2014 Class A Voltage Fluctuations & Flicker EN 61000-3-3:2013 EMC Immunity EN 61204-3:2020, IEC 61000-4-2, 3, 4, 5, 6, 11 Electrostatic Discharge (ESD) Radio-Frequency, Continuous Radiated Disturbance Electrical Fast Transient (EFT) IEC 61000-4-2:2008, Air Discharge: ±8kV Contact, Discharge: ±4kV Criterion A IEC 61000-4-3:2010 Criterion A IEC 61000-4-4:2012, ±1kV Criterion A Surge Conducted Disturbances, Induced by RF Fields Voltage Dips IEC 61000-4-5:2014, L-N: ±1kV Criterion A IEC 61000-4-6:2013 Criterion A IEC 61000-4-11:2004, Dips: 30% Reduction, Dips: >95% Reduction Criterion A Voltage Interruptions IEC 61000-4-11:2004, >95% Reduction EMC Emission Application Note Link Ed.3.0 Criterion B CFM40D/T Series App Notes CHARACTERISTIC CURVE Power Derating Curve Open Frame versions CFM40D/T Series Rate Load (%) 100% 75% 50% 20 LFM(Natural Convection) 25% 0% 0 10 20 30 40 50 60 70 Ambient Temperature(℃) www.cincon.com 7 REVISION: V15 CFM40D/T Covered versions: CFM40T-07-CA CFM40D-01/02,CFM40T-01/02/03/04/05/06-CA 80% 80% Rate Load (%) 100% Rate Load (%) 100% 60% 40% 20 LFM(Natural Convection) 20% Series 0% 60% 40% 20 LFM(Natural Convection) 20% 0% 0 10 20 30 40 50 60 0 10 Ambient Temperature(℃) 20 30 40 50 60 Ambient Temperature(℃) Performance Data CFM40D-02 (Eff Vs Io) 90% 85% 85% Efficiency (%) Efficiency (%) CFM40D-01 (Eff Vs Io) 90% 80% 75% 115V 70% 65% 10% 230V 20% 30% 40% 50% 60% 70% 80% 80% 75% 65% 10% 90% 100% 115V 70% 230V 20% 30% Current Load (%) 85% 85% 80% 75% 115V 70% 230V 30% 40% 50% 60% 70% 80% 90% 100% Current Load (%) www.cincon.com 60% 70% 80% 90% 100% CFM40T-02 (Eff Vs Io) 90% Efficiency (%) Efficiency (%) CFM40T-01 (Eff Vs Io) 20% 50% Current Load (%) 90% 65% 10% 40% 80% 75% 115V 70% 65% 10% 230V 20% 30% 40% 50% 60% 70% 80% 90% 100% Current Load (%) 8 REVISION: V15 CFM40D/T CFM40T-04 (Eff Vs Io) 90% 90% 85% 85% Efficiency (%) Efficiency (%) CFM40T-03 (Eff Vs Io) 80% 75% 115V 70% 65% 10% 230V 20% 30% 40% 50% 60% 70% 80% 80% 75% 70% 65% 10% 90% 100% 115V 230V 20% 30% Current Load (%) 85% 85% 80% 75% 115V 70% 230V 30% 40% 50% 60% 70% 50% 60% 70% 80% 90% 100% CFM40T-06 (Eff Vs Io) 90% Efficiency (%) Efficiency (%) CFM40T-05 (Eff Vs Io) 20% 40% Current Load (%) 90% 65% 10% Series 80% 90% 100% Current Load (%) 80% 75% 115V 70% 65% 10% 230V 20% 30% 40% 50% 60% 70% 80% 90% 100% Current Load (%) CFM40T-07 (Eff Vs Io) 80% Efficiency (%) 75% 70% 65% 115V 60% 55% 10% 230V 20% 30% 40% 50% 60% 70% 80% 90% 100% Current Load (%) www.cincon.com 9 REVISION: V15 CFM40D/T Series MECHANICAL SPECIFICATION CFM40D/T Open Frame CFM40D/T with Cover sales@cincon.com www.cincon.com 10 REVISION: V15
CFM40T-03 价格&库存

很抱歉,暂时无法提供与“CFM40T-03”相匹配的价格&库存,您可以联系我们找货

免费人工找货