DIN RANGE PANEL METERS
DESCRIPTION
Available with moving iron or
moving coil movements for a.c.
or d.c. use, these DIN panel meters
have been supplied worldwide and
are recognised for their quality
and value. Standard scales or
customised dials can be offered.
11840
• Manufactured to:
DIN 43700, IEC51 and BS89.
• 48mm, 72mm and 96mm sizes.
• a.c. or d.c. use.
• Interchangeable dials (72mm & 96mm).
• Rugged pivot and jewel movement.
• Ammeters, Voltmeters, Frequency
Meters, Power Factor Indicators,
Wattmeters, Elapsed Time Indicators
and Maximum Demand Indicators.
• Optional red secondary pointer and
terminal cover.
• Special customised dials.
Howard Butler Limited is one of the largest
independent UK manufacturers of panel meters
and associated products.
With over 80 years experience in the industry
HOBUT products have built a reputation for
high quality and modern design at
competitive prices.
A N A L O G U E PA N E L M E T E R S • D I G I TA L PA N E L M E T E R S • H O U R S C O U N T E R S • S E L E C T O R S W I T C H E S • P R O T E C T I O N R E L AY S • T R A N S D U C E R S
S H U N T S • C U R R E N T T R A N S F O R M E R S • C H A R G E R M E T E R S • T H E R M A L C U T O U T S • M U LT I - F U N C T I O N M E T E R S
DIN DIN DIN
96 72 48
DIN RANGE PANEL METERS
MOVING IRON
Types:
Accuracy:
D48SD, D72SD, D96SD.
Class 1.5 (Class 2.5-60A and
above).
• 1A to 100A direct connected
(D48SD - 40A max).
• 1A or 5A CT operated.
• 30V to 600V direct connected.
0.7VA typical for 1A or 5A CT
operated at 50Hz.
1.2VA max up to 30A
2.4VA max for 40A to 100A.
6VA max for voltmeters up
to 600V.
Calibrated at 50Hz.
Specify for frequencies 15Hz up
to 400Hz
Standard ammeter and voltmeter
scales.(2x and 6x overload ammeter scales available on request).
Heavily damped movements
available.
AC ratings:
Burden:
Frequency:
Scaling:
Moving Iron panel meters can be
used for D.C. operation at
reduced accuracy.
MOVING COIL
Damping:
Types:
Accuracy:
DC ratings:
AC ratings:
DC burden:
Non std.:
CONNECTION
DIAGRAMS
VOLTMETER
VOLTAGE
TRANSFORMER
OPERATED
DIRECT
CONNECTED
u
U
•••
v
V
L1
(L)
L2
(N)
AMMETER
CURRENT
TRANSFORMER
OPERATED
DIRECT
CONNECTED
L1
k
l
K
L
L2
D48MC, D72MC, D96MC.
Class 1.5.
• 100µA to 50A direct connected
(D48MC - 40A max).
• 4-20mA, 1mA or 20mA
transducer operated.
• 50mV to 600V direct connected.
• 50mV to 300mV shunt operated.
• Rectifier types available for a.c.
use (mean sensitivity).
80mV to 150mV volt drop for
direct connect ammeters 1mA
(1000Ω/V) for voltmeters and
shunt operated ammeters.
Suppressed zero voltmeters and
trim potentiometer types
available.
VOLTMETER
+
-
•••
+
AMMETER
DIRECT
CONNECTED
SHUNT
OPERATED
+
+
+
Type:
Accuracy:
AC ratings:
WATTMETER
D96WA.
Class 1.5.
• 1A or 5A CT operated.
• 63.5V to 500V direct connected.
Current
很抱歉,暂时无法提供与“D72A30”相匹配的价格&库存,您可以联系我们找货