Surge arrester
2-Electrode arrester
Series/Type:
DG401A
Customer:
Version/Date:
Issue 02/2015-9-9
DC Elec. 2015 . Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
Surge arrester
2-Electrode arrester
DG401A
Features
Extremely small size
Extremely fast response time
Eexcllent SMD handing
Applications
●
●
●
Splitter
PCI Cards
Morden
Stable performance over life
Very low capacitance
High insulation resistance
RoHS-compatible
UL-identification, No:E311500
●
Line cards
●
●
●
●
●
●
●
●
Electrical specifications
DC breakdown voltage 2) 3)
——Circuit current less than 2mA
400
±20
V
%
≤900
V
GΩ
Impulse breakdown voltage 1)
at 1kv/us
-Typical values of distribution
Insulation resistance at DC 100V
Capacitance at 1MHz
Service life 2)
2)
10 operations
10 operations
8/20us
50Hz
≥1
≤1
Pf
Weight
1
1
~1
KA
A
g
Storage and operations temperature
Climatic category(GB/T 9043,IEC61643-1)
Marking,Red positive
-40…+90
40/90/21
Without
°C
Tel:
+86-510-81707285
Fax:
+86-510-81707277
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 02/2015-9-9
Page 2 of 4
Surge arrester
2-Electrode arrester
DG401A
DC breakdown voltage
8/20us, Test wave
10/700us,Test Wave
10/1000us,Test Wave
T1=1.25T=8us±20%
T1=1.67T=10us±20%
T1=1.67T=10us±20%
T2=20us±20%
T2=700us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 02/2015-9-9
Page 3 of 4
Surge arrester
2-Electrode arrester
1)
2)
3)
DG401A
Sampling size in accordance to AQL(C=0)
DC spark-over voltage ±30% after load
Tests according to ITU-T Rec. K. 12 and IEC61643-1
Dimensions
Wire Tin-plated
Packaging
One reel with 3000pcs
Cautions and warnings
●
Surge arresters must not be operated directly in power supply networks
●
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
●
If the contacts of the surge arrester are defective, current stress can lead to the formation of
sparks and loud noises.
●
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
●
Damaged surge arresters must not be re-used.
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 02/2015-9-9
Page 4 of 4
很抱歉,暂时无法提供与“DG401A”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 5+0.81670
- 50+0.65254
- 150+0.57046