Surge arrester
2-Electrode arrester
Series/Type:
DG2R3000L
Customer:
Version/Date:
Issue 01/2017-10-19
DC Elec. 2017 . Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
Surge arrester
2-Electrode arrester
DG2R3000L
Features
●
●
●
●
●
●
Applications
Extremely small size
Extremely fast response time
Stable performance over life
Very low capacitance
● Consumer electronics
● AC Power line devices
● Power supplier
High insulation resistance
RoHS-compatible
Electrical specifications
DC breakdown voltage 1)2)
Tolerance
Min.
Max.
Impulse breakdown voltage
at 1kv/us
3000
±20
2400
V
%
V
3600
V
≤4200
–For 99% measure values
–Typical values of distribution ≤4000
Service life
10 operations
50Hz,1S
10 operations
8/20us
Insulation resistance at DC 100V
V
V
5
5
≥1
A
KA
GΩ
Capacitance at 1MHz
AC withstand voltage
1S
≤1.5
pF
1500
V
Weight
Storage and operations temperature
Climatic category(IEC60068-1)
1.5
-40…+90
40/90/21
g
°C
Marking,Blue positive
DG2R3000L
Tel:
+86-510-81707285
Fax:
+86-510-81707277
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2017-10-19
Page 2 of 4
Surge arrester
2-Electrode arrester
DG2R3000L
DC breakdown voltage
8/20us, Test wave
10/700us,Test Wave
10/1000us,Test Wave
T1=1.25T=8us±20%
T1=1.67T=10us±20%
T1=1.67T=10us±20%
T2=20us±20%
T2=700us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2017-10-19
Page 3 of 4
Surge arrester
2-Electrode arrester
1)
2)
3)
Sampling size in accordance to AQL(C=0)
In ionized mode
Tests according to ITU-T Rec. K. 12 IEC61663-2 and IEC61643-311
DG2R3000L
Dimensions
Cautions and warnings
Surge arresters must not be operated directly in power supply networks,whose maximum operating
voltage exceeds the minimum spark-over voltage of the surge arresters.
●
●
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
●
If the contacts of the surge arrester are defective, current stress can lead to the formation of sparks and loud noises.
Surge arresters may be used only within their specified values. In case of overload, the head contacts
may fail or the component may be destroyed.
●
●
Damaged surge arresters must not be re-used.
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2017-10-19
Page 4 of 4