Surge arrester
2-Electrode arrester
Series/Type:
DG2R350L
Customer:
Version/Date:
Issue 03/2015-07-19
DC Elec. 2015 . Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
Surge arrester
2-Electrode arrester
DG2R350L
Features
●
●
●
●
●
●
●
●
Applications
Extremely small size
Extremely fast response time
Eexcllent SMD handing
Stable performance over life
Very low capacitance
High insulation resistance
●
●
●
●
Splitter
PCI Cards
Morden
Line cards
RoHS-compatible
UL-identification, No:E311500
Electrical specifications
DC breakdown voltage 2) 3)
——Circuit current less than 2mA
Impulse breakdown voltage 1)
at 1kv/us
-Typical values of distribution
350
V
±20
%
800
V
1
1
GΩ
Pf
5
5
100
100
KA
A
A
A
Weight
Storage and operations temperature
~0.7
-40…+90
g
°C
Climatic category(GB/T 9043,IEC61643-1)
Marking,Blue positive
40/90/21
Insulation resistance at DC 100V
2)
Capacitance at 1MHz
Service life 2)
10 operations
10 operations
1 operation
500 operations
8/20us
50Hz,1S
50Hz,9 cycles
10/1000us
DG2R350L
Tel:
Fax:
+86-510-81707285
+86-510-81707277
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 03/2015-07-19
Page 2 of 4
Surge arrester
2-Electrode arrester
DG2R350L
DC breakdown voltage
8/20us, Test wave
10/700us,Test Wave
10/1000us,Test Wave
T1=1.25T=8us±20%
T1=1.67T=10us±20%
T1=1.67T=10us±20%
T2=20us±20%
T2=700us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 03/2015-07-19
Page 3 of 4
Surge arrester
2-Electrode arrester
1)
2)
3)
DG2R350L
Sampling size in accordance to AQL(C=0)
DC spark-over voltage ±30% after load
Tests according to ITU-T Rec. K. 12 and IEC61643-1
Dimensions
Wire Tin-plated
Packaging
100pcs/box
Cautions and warnings
●
Surge arresters must not be operated directly in power supply networks
●
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
●
If the contacts of the surge arrester are defective, current stress can lead to the formation of
sparks and loud noises.
●
Surge arresters may be used only within their specified values. In case of overload, the head
contacts may fail or the component may be destroyed.
●
Damaged surge arresters must not be re-used.
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 03/2015-07-19
Page 4 of 4
很抱歉,暂时无法提供与“DG2R350L”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 1+1.75338
- 10+1.41318
- 30+1.26738