Surge arrester
2-Electrode arrester
Series/Type:
DG2R470L
Customer:
Version/Date:
Issue 01/2014-5-20
DC Elec. 2017 . Reproduction,publication and dissemination of this document, enclosures here to and the
information contained therein without DC' prior express consent is prohibited.
Surge arrester
2-Electrode arrester
Features
●
●
●
●
●
●
●
Extremely small size
Extremely fast response time
Stable performance over life
Very low capacitance
DG2R470L
Applications
●
●
●
●
Splitter
PCI Cards
Morden
Line Cards
High insulation resistance
RoHS-compatible
UL Certicfication :E311500
Electrical specifications
DC breakdown voltage 1)2)
470
±20
375
Tolerance
V
%
V
Min.
564
Max.
Impulse breakdown voltage
at 1kv/us
–Typical values of distribution ≤1100
Service life
10 operations
50Hz,1S
10
V
V
A
10 operations
8/20us
Insulation resistance at DC 100V
10
≥1
KA
GΩ
Capacitance at 1MHz
Weight
Storage and operations temperature
Climatic category(IEC60068-1)
≤1.5
1.5
-40…+90
40/90/21
pF
g
°C
Marking,Blue positive
DG2R470L
www.jsdgme.com
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2014-5-20
Page 2 of 4
Surge arrester
2-Electrode arrester
DG2R470L
DC breakdown voltage
8/20us, Test wave
10/700us,Test Wave
10/1000us,Test Wave
T1=1.25T=8us±20%
T1=1.67T=10us±20%
T1=1.67T=10us±20%
T2=20us±20%
T2=700us±20%
T2=1000us±20%
Recommended wave slodering profile
DC Elec.
Please read Cautions and warnings and
important notes at the end of this document.
Issue 01/2014-5-20
Page 3 of 4
Surge arrester
2-Electrode arrester
1)Sampling size in accordance to AQL0.65 II
2) Tests according to ITU-T Rec. K. 12 and IEC61643-311 or GB/T 9043
DG2R470L
Dimensions
Cautions and warnings
Surge arresters must not be operated directly in power supply networks,whose maximum operating
voltage exceeds the minimum spark-over voltage of the surge arresters.
●
●
Surge arresters may become hot in case of longer periods of current stress (danger of burning).
●
If the contacts of the surge arrester are defective, current stress can lead to the formation of sparks and loud noises.
Surge arresters may be used only within their specified values. In case of overload, the head contacts
may fail or the component may be destroyed.
●
●
Damaged surge arresters must not be re-used.
DC Elec.