EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Features
Compact Metal Case with Excellent Thermal Performance
Full Power at Wide Output Current Range (Constant Power)
Adjustable Output Current (AOC) with Programmability
Isolated 1-5V/1-10V/10V PWM/3-Timer-Modes Dimmable
Output Lumen Compensation
Input Surge Protection: DM 6kV, CM 10kV
All-Around Protection: OVP, SCP, OTP
IP66 / IP67 and UL Dry / Damp / Wet Location
Class 2 & SELV Output
TYPE HL, for use in a Class I, Division 2 hazardous
(Classified) location
UL Class P Type
5 Years Warranty
Description
The EUM-100SxxxDT series is a 100W, constant-current, programmable IP67 LED driver that operates from 90305Vac input with excellent power factor. It is created for many lighting applications including high bay, tunnel
and roadway, etc. The high efficiency of these drivers and compact metal case enables them to run cooler,
significantly improving reliability and extending product life. To ensure trouble-free operation, protection is
provided against input surge, output over voltage, short circuit, and over temperature.
Models
Adjustable
Output
Current
Range
Full-Power
Current
Range (1)
Default
Output
Current
Input
Voltage
Range(2)
Output
Voltage
Range
Max.
Typical Power Factor
Output Efficiency
120Vac 220Vac
Power
(3)
90~305 Vac/
48~143 Vdc 100W
127~300 Vdc
90~305 Vac/
105-1500mA 1050-1500mA 1050 mA
34~95 Vdc 100W
127~300 Vdc
90~305 Vac/
175-2800mA 1750-2800mA 2100 mA
17~54 Vdc 96W
127~300 Vdc
70-1050mA
700-1050mA
700 mA
Model Number
93.0%
0.99
0.96 EUM-100S105DT
93.0%
0.99
0.96 EUM-100S150DT
(4)
92.0%
0.99
0.96 EUM-100S280DT
(5)
Notes: (1) Output current range with constant power at 100W
(2) Certified input voltage range: UL, FCC 100-277Vac; otherwise 100-240Vac.
(3) Measured at 100% load and 220Vac input (see below “General Specifications” for details).
(4) SELV Output.
(5) Class 2 & SELV output.
1 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
I-V Operation Area
EUM-100S105DT
EUM-100S150DT
EUM-100S280DT
Input Specifications
Parameter
Min.
Typ.
Max.
Input Voltage
90 Vac
-
305 Vac
Input Frequency
47 Hz
-
63 Hz
-
-
0.75 MIU
UL8750; 277Vac/ 60Hz
-
-
0.70 mA
IEC60598-1; 240Vac/ 60Hz,
-
-
1.0 A
Measured at 100% load and 120 Vac input.
-
-
0.54 A
Measured at 100% load and 220 Vac input.
-
-
2.07 A s
Leakage Current
Input AC Current
2
Inrush Current(I t)
2
Notes
127~300 Vdc
At 220Vac input, 25°C cold start,
duration=224 μs, 10%Ipk-10%Ipk. See
Inrush Current Waveform for the details.
2 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Input Specifications (Continued)
Parameter
Min.
Typ.
Max.
Notes
0.9
-
-
THD
-
-
20%
At 100-277Vac, 50-60Hz, 65%-100% Load
(65-100W)
THD
-
-
10%
Min.
Typ.
Max.
-5%Ioset
-
5%Ioset
70 mA
105 mA
175 mA
-
1050 mA
1500 mA
2800 mA
700 mA
1050 mA
1750 mA
-
1050 mA
1500 mA
2800 mA
-
5%Iomax
10%Iomax
Output Current Ripple at
< 200 Hz (pk-pk)
-
2%Iomax
-
Startup Overshoot Current
-
-
10%Iomax
No Load Output Voltage
EUM-100S105DT
EUM-100S150DT
EUM-100S280DT
-
-
170 V
120 V
60 V
Line Regulation
-
-
±0.5%
Load Regulation
-
-
±1.5%
Turn-on Delay Time
-
-
0.5 s
Temperature Coefficient of
Ioset
-
0.03%/°C
-
PF
At 220-240Vac, 50-60Hz, 75%-100% Load
(75-100W)
Output Specifications
Parameter
Output Current Tolerance
Output Current Setting(Ioset)
Range
EUM-100S105DT
EUM-100S150DT
EUM-100S280DT
Output Current Setting Range
with Constant Power
EUM-100S105DT
EUM-100S150DT
EUM-100S280DT
Total Output Current Ripple
(pk-pk)
Notes
At 100% load condition
At 100% load condition. 20 MHz BW
At 100% load condition. Only this
component of ripple is associated with
visible flicker.
At 100% load condition
Measured at 100% load
Measured at 120-277Vac input,
65%-100% Load
Case temperature = 0°C ~Tc max
Note: All specifications are typical at 25°C unless otherwise stated.
3 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
General Specifications
Parameter
Min.
Typ.
Max.
87.50%
88.50%
89.50%
90.50%
-
88.00%
89.00%
90.00%
91.00%
-
87.50%
88.00%
89.50%
90.00%
-
90.00%
91.00%
92.00%
93.00%
-
90.00%
91.00%
92.00%
93.00%
-
89.50%
90.00%
91.50%
92.00%
-
90.50%
91.50%
92.50%
93.50%
-
90.50%
91.00%
92.50%
93.00%
-
89.50%
90.00%
91.50%
92.00%
-
MTBF
-
473,000
Hours
-
Lifetime
-
114,000
Hours
-
Operating Case Temperature
for Safety Tc_s
-40°C
-
+90°C
Operating Case Temperature
for Warranty Tc_w
-40°C
-
+80°C
Case temperature for 5 years warranty
Humidity: 10% RH to 95% RH;
Storage Temperature
-40°C
-
+85°C
Humidity: 5% RH to 95% RH;
Efficiency at 120 Vac input:
EUM-100S105DT
Io= 700 mA
Io=1050 mA
EUM-100S150DT
Io=1050 mA
Io=1500 mA
EUM-100S280DT
Io=1750 mA
Io=2800 mA
Efficiency at 220 Vac input:
EUM-100S105DT
Io= 700 mA
Io=1050 mA
EUM-100S150DT
Io=1050 mA
Io=1500 mA
EUM-100S280DT
Io=1750 mA
Io=2800 mA
Efficiency at 277 Vac input:
EUM-100S105DT
Io= 700 mA
Io=1050 mA
EUM-100S150DT
Io=1050 mA
Io=1500 mA
EUM-100S280DT
Io=1750 mA
Io=2800 mA
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Net Weight
Measured at 100% load and steady-state
temperature in 25°C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 100% load and steady-state
temperature in 25°C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 100% load and steady-state
temperature in 25°C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 220Vac input, 80%Load and
25°C ambient temperature (MIL-HDBK217F)
Measured at 220Vac input, 80%Load and
70°C case temperature; See lifetime vs. Tc
curve for the details
With mounting ear
5.83 × 2.36 × 1.34
148 × 60 × 34
5.16 × 2.36 × 1.34
131 × 60 × 34
-
595 g
Notes
-
Note: All specifications are typical at 25°C unless otherwise stated.
4 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Dimming Specifications
Parameter
Min.
Typ.
Max.
-20 V
-
20 V
200 μA
300 μA
450 μA
10%Ioset
-
Ioset
70 mA
105 mA
175 mA
-
Ioset
0.25 V
-
4.75 V
Dimming mode set to 1-5V in PC interface.
1V
-
9V
Default 1-10V dimming mode with positive
logic.
PWM_in High Level
-
10V
-
PWM_in Low Level
-
0V
-
200 Hz
-
2 KHz
0%
-
100%
Absolute Maximum Voltage
on the Vdim (+) Pin
Source Current on Vdim
(+)Pin
EUM-100S105DT
EUM-100S150DT
Dimming EUM-100S280DT
Output
EUM-100S105DT
Range
EUM-100S150DT
EUM-100S280DT
Recommended Dimming
Range for 1-5V
Recommended Dimming
Range for 1-10V
PWM_in Frequency Range
PWM_in Duty Cycle
Notes
Vdim(+) = 0 V
700 mA ≤ Ioset ≤ 1050 mA
1050 mA ≤ Ioset ≤ 1500 mA
1750 mA ≤ Ioset ≤ 2800 mA
70 mA ≤ Ioset < 700 mA
105 mA ≤ Ioset < 1050 mA
175 mA ≤ Ioset < 1750 mA
Safety &EMC Compliance
Safety Category
UL/CUL
Standard
UL8750,CAN/CSA-C22.2 No. 250.13
CE
EN 61347-1, EN61347-2-13
KS
KS C 7655
EMI Standards
(1)
EN 55015
Notes
Conducted emission Test &Radiated emission Test
EN 61000-3-2
Harmonic current emissions
EN 61000-3-3
Voltage fluctuations & flicker
ANSI C63.4 Class B
(1)
FCC Part 15
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: [1] this device may not cause harmful interference, and [2] this
device must accept any interference received, including interference that may cause
undesired Operation.
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4
Electrical Fast Transient / Burst-EFT
EN 61000-4-5
Surge Immunity Test: AC Power Line: Differential Mode 6 kV, Common Mode 10 kV
5 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Safety &EMC Compliance (Continued)
EMS Standards
Notes
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8
Power Frequency Magnetic Field Test
EN 61000-4-11
Voltage Dips
EN 61547
Electromagnetic Immunity Requirements Applies To Lighting Equipment
Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it
depends also on the other devices connected to the driver and on the fixture itself.
Derating
Lifetime vs. Case Temperature
6 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Inrush Current Waveform
Efficiency vs. Load
EUM-100S105DT(Io=700mA)
EUM-100S105DT(Io=1050mA)
EUM-100S150DT(Io=1050mA)
EUM-100S150DT(Io=1500mA)
7 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
EUM-100S280DT(Io=1750mA)
EUM-100S280DT(Io=2800mA)
Power Factor
Total Harmonic Distortion
8 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Protection Functions
Parameter
Notes
Over Temperature Protection
Decreases output current, returning to normal after over temperature is removed.
Short Circuit Protection
Auto Recovery. No damage will occur when any output is short circuited. The output
shall return to normal when the fault condition is removed.
Over Voltage Protection
Limits output voltage at no load and in case the normal voltage limit fails.
Dimming
1-5V Dimming
The recommended implementation of the dimming control is provided below.
Implementation 1: Positive logic
Implementation 2: Negative logic
Notes:
1. The dimmer can also be replaced by an active 1-5V voltage source signal or passive components like
resistors and zener.
2. If 1-5V dimming is not used, Dim + should be open.
3. When 1-5V negative logic dimming mode and Dim+ is open, the driver will output maximum current.
9 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
1-10V Dimming
The recommended implementation of the dimming control is provided below.
Implementation 3: Positive logic
Implementation 4: Negative logic
Notes:
1. The dimmer can also be replaced by an active 1-10V voltage source signal or passive components like
resistors and zener.
2. If 1-10V dimming is not used, Dim + should be open.
3. When 1-10V negative logic dimming mode and Dim+ is open, the driver will output minimum current.
10V PWM Dimming
The recommended implementation of the dimming control is provided below.
Implementation 5: Positive logic
10 / 13
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUM-100SxxxDT
100W Programmable IP67 Driver
Rev. A
Implementation 6: Negative logic
Notes:
1. If PWM dimming is not used, Dim + should be open.
2. When PWM negative logic dimming mode and Dim+ is open, the driver will output minimum current.
Time Dimming
Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self AdaptingPercentage and Traditional Timer.
• Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two
days (if difference
很抱歉,暂时无法提供与“EUM-100S150DT”相匹配的价格&库存,您可以联系我们找货
免费人工找货