EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Features
Ultra High Efficiency (Up to 93.0%)
Full Power at Wide Output Current Range (Constant Power)
Thermal Sensing and Protection for LED Module
DALI/Timer Dimmable (3 Timer Modes)
Dim-to-Off with Standby Power ≤ 0.5 W
Always-on Auxiliary Power: 12Vdc, 200mA (Transient Peak
Current up to 400mA)
Output Lumen Compensation
Input Surge Protection: 6kV line-line, 10kV line-earth
All-Around Protection: OVP, SCP, OTP
Waterproof (IP67)
SELV Output
Suitable for Independent Use
7 Years Warranty
Description
The EUD-096SxxxBVA series is a 96W, constant-current, programmable LED driver that operates from 90-305
Vac input with excellent power factor. Created for low bay, tunnel and street lights, it provides a dim-to-off mode
with low standby power. The high efficiency of these drivers and compact metal case enables them to run cooler,
significantly improving reliability and extending product life. To ensure trouble-free operation, protection is
provided against input surge, output over voltage, short circuit, and over temperature.
Models
Adjustable
Output
Current
Range
Full-Power
Current
Range (1)
Default
Output
Current
Input
Voltage
Range(2)
90~305 Vac/
127~250 Vdc
90~305 Vac/
70-1050mA 700-1050mA 700 mA
127~250 Vdc
90~305 Vac/
140-2100mA 1400-2100mA 2100 mA
127~250 Vdc
90~305 Vac/
245-3500mA 2450-3500mA 2800 mA
127~250 Vdc
45-700mA
450-700mA
530 mA
Output
Voltage
Range
Max.
Typical Power Factor
Output Efficiency
120Vac 220Vac
Power
(3)
Model Number
74~213Vdc 96 W
91.5%
0.99
0.96
EUD-096S070BVA
(4)
48~137Vdc 96 W
92.5%
0.99
0.96
EUD-096S105BVA
(4)
24 ~ 69Vdc 96 W
93.0%
0.99
0.96
EUD-096S210BVA
(5)
14 ~ 39Vdc 96 W
91.0%
0.99
0.96
EUD-096S350BVA
(5)
Notes: (1) Output current range with constant power at 96W
(2) Certified voltage range: 100-240Vac or 127-250Vdc (except CCC, PSE and KS).
(3) Measured at full load and 220Vac input (see below “General Specifications” for details).
(4) They are certificated to Global-mark
(5) SELV Output
1 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
I-V Operation Area
EUD-096S070BVA
EUD-096S105BVA
EUD-096S210BVA
EUD-096S350BVA
Input Specifications
Parameter
Min.
Typ.
Max.
Input Voltage
90 Vac
-
305 Vac
Input Frequency
47 Hz
-
63 Hz
Leakage Current
-
-
0.70 mA
-
-
1.32 A
Measured at full load and 100 Vac input.
-
-
0.60 A
Measured at full load and 220 Vac input.
-
-
1.10 A s
Input AC Current
2
Inrush Current(I t)
2
Notes
127-250 Vdc
IEC60598-1; 240Vac/ 60Hz
At 220Vac input, 25℃ cold start,
duration=576 μs, 10%Ipk-10%Ipk. See
Inrush Current Waveform for the details.
2 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Input Specifications (Continued)
Parameter
Min.
Typ.
Max.
0.90
-
-
THD
-
-
20%
THD
-
-
10%
Min.
Typ.
Max.
-5%Ioset
-
5%Ioset
45 mA
70 mA
140 mA
245 mA
-
700 mA
1050 mA
2100 mA
3500 mA
450 mA
700 mA
1400 mA
2450 mA
-
700 mA
1050 mA
2100 mA
3500 mA
-
5%Iomax
10%Iomax
-
2%Iomax
-
Startup Overshoot Current
-
-
10%Iomax
No Load Output Voltage
EUD-096S070BVA
EUD-096S105BVA
EUD-096S210BVA
EUD-096S350BVA
-
-
240 V
170 V
90 V
44 V
Line Regulation
-
-
±0.5%
Load Regulation
-
-
±1.5%
-
-
1.0 s
-
-
0.5 s
-
0.03%/C
-
12V Auxiliary Output Voltage
10.8 V
12 V
13.2 V
12V Auxiliary Output Source
Current
0 mA
-
200 mA
Return terminal is “OTP−“
400 mA
400mA peak for a maximum duration of
300ms in a 2s period during which time the
average should not exceed 200mA.
PF
Notes
At 100-240Vac, 50-60Hz, 60%-100% Load
(58-96W)
At 220-240Vac, 50-60Hz, 75%-100% Load
(72-96W)
Output Specifications
Parameter
Output Current Tolerance
Output Current Setting(Ioset)
Range
EUD-096S070BVA
EUD-096S105BVA
EUD-096S210BVA
EUD-096S350BVA
Output Current Setting Range
with Constant Power
EUD-096S070BVA
EUD-096S105BVA
EUD-096S210BVA
EUD-096S350BVA
Total Output Current Ripple
(pk-pk)
Output Current Ripple at
< 200 Hz (pk-pk)
12V Auxiliary Output
Transient Peak Current
-
-
At full load condition
At full load condition, 20 MHz BW
At full load condition. Only this component
of ripple is associated with visible flicker.
Turn-on Delay Time
Temperature Coefficient of
Ioset
Notes
At full load condition
Measured at full load
Measured at 120Vac input, 60%-100%
Load.
Measured at 220Vac input, 60%-100%
Load.
Case temperature = 0C ~Tc max
Note: All specifications are typical at 25C unless otherwise stated.
3 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
General Specifications
Parameter
Efficiency at 120 Vac input:
EUD-096S070BVA
Io= 450mA
Io= 700mA
EUD-096S105BVA
Io= 700mA
Io=1050mA
EUD-096S210BVA
Io=1400mA
Io=2100mA
EUD-096S350BVA
Io=2450mA
Io=3500mA
Efficiency at 220 Vac input:
EUD-096S070BVA
Io= 450mA
Io= 700mA
EUD-096S105BVA
Io= 700mA
Io=1050mA
EUD-096S210BVA
Io=1400mA
Io=2100mA
EUD-096S350BVA
Io=2450mA
Io=3500mA
Efficiency at 277 Vac input:
EUD-096S070BVA
Io= 450mA
Io= 700mA
EUD-096S105BVA
Io= 700mA
Io=1050mA
EUD-096S210BVA
Io=1400mA
Io=2100mA
EUD-096S350BVA
Io=2450mA
Io=3500mA
Standby power
Min.
Typ.
Max.
87.0%
85.5%
90.0%
88.5%
-
88.0%
86.5%
91.0%
89.5%
-
88.0%
86.0%
91.0%
89.0%
-
86.5%
84.5%
89.5%
87.5%
-
89.5%
88.5%
91.5%
90.5%
-
90.5%
88.5%
92.5%
90.5%
-
91.0%
88.5%
93.0%
90.5%
-
89.0%
87.5%
91.0%
89.5%
-
90.0%
88.5%
92.0%
90.5%
-
91.0%
89.0%
93.0%
91.0%
-
91.0%
89.0%
93.0%
91.0%
-
89.5%
87.5%
91.5%
89.5%
-
-
-
0.5 W
Notes
Measured at full load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at full load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at full load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 230Vac/50Hz; Dimming off
Measured at 220Vac input, 80%Load and
25C ambient temperature (MIL-HDBK217F)
Measured at 220Vac input, 80%Load and
70C case temperature; See lifetime vs. Tc
curve for the details
MTBF
-
229,000
Hours
-
Lifetime
-
104,000
Hours
-
Operating Case Temperature
for Safety Tc_s
-40°C
-
+90°C
Operating Case Temperature
for Warranty Tc_w
-40°C
-
+75°C
Case temperature for 7 years warranty.
Please see Inventronics Warranty
Statement for complete details.
Storage Temperature
-40°C
-
+85°C
Humidity: 5%RH to 100%RH
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Net Weight
With mounting ear
7.92 × 2.66 × 1.44
201 × 67.5 × 36.5
7.09 × 2.66 × 1.44
180 × 67.5 × 36.5
-
960 g
-
Note: All specifications are typical at 25C unless otherwise stated.
4 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Dimming Specifications
Parameter
Min.
Typ.
Max.
DA, DA High Level
9.5V
16V
22.5V
DA, DA Low Level
-6.5V
0V
6.5V
DA, DA Current
0mA
-
2mA
EUD-096S070BVA
EUD-096S105BVA
EUD-096S210BVA
Dimming EUD-096S350BVA
Output
EUD-096S070BVA
Range
EUD-096S105BVA
EUD-096S210BVA
EUD-096S350BVA
10%Ioset
-
Ioset
45mA
70mA
140mA
245mA
-
Ioset
Notes
450mA≤ Ioset ≤ 700mA
700mA ≤ Ioset ≤ 1050mA
1400mA≤ Ioset ≤ 2100mA
2450mA ≤ Ioset≤ 3500mA
45mA ≤ Ioset < 450mA
70mA ≤ Ioset < 700mA
140mA ≤ Ioset < 1400mA
245mA ≤ Ioset < 2450mA
Note: All specifications are typical at 25 C unless stated otherwise.
Standards Compliance
Safety Category
Standard
CE
EN 61347-1, EN61347-2-13
KS
KS C 7655
EMI Standards
EN 55015(1)
Notes
Conducted emission Test &Radiated emission Test
EN 61000-3-2
Harmonic current emissions
EN 61000-3-3
Voltage fluctuations & flicker
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4
Electrical Fast Transient / Burst-EFT
EN 61000-4-5
Surge Immunity Test: AC Power Line: line to line 6 kV, line to earth 10 kV
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8
Power Frequency Magnetic Field Test
EN 61000-4-11
Voltage Dips
EN 61547
Electromagnetic Immunity Requirements Applies To Lighting Equipment
DALI Standards
DALI
(2)
Notes
IEC62386-101,102 & part of 207
(3)
Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that
contains it depends also on the other devices connected to the driver and on the fixture itself.
(2) To perform electric strength (hi-pot) testing, the “GDT ground disconnect” (nut and metal lock
sheet) on the driver end-cap should be removed temporarily to prevent the internal gas discharge
tube from conducting (as allowed by IEC 60598-1 Clause 10.2). After testing is completed, these
items must be reinstalled to restore line-to-earth surge protection and secure the end cap.
(3) Optional Commands Implemented: 242 (query short circuit), 243 (query open circuit)
5 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Lifetime vs. Case Temperature
Inrush Current Waveform
Efficiency vs. Load
EUD-096S070BVA(Io=450mA)
EUD-096S070BVA(Io=700mA)
6 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
EUD-096S105BVA(Io=700mA)
EUD-096S105BVA(Io=1050mA)
EUD-096S210BVA(Io=1400mA)
EUD-096S210BVA(Io=2100mA)
EUD-096S350BVA(Io=2450mA)
EUD-096S350BVA(Io=3500mA)
7 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Power Factor
Total Harmonic Distortion
Protection Functions
Parameter
External
Thermal
Protection
NTC
Min.
Typ.
Max.
R1
-
7.81 kOhm
-
When R_NTC falls below R1, External
Thermal Protection is triggered, reducing
output current until R2 is reached.
R2
-
4.16 kOhm
-
When R_NTC is less than R2, output current
is reduced to the programmed “Protection
Current Floor.”
10%Ioset
60%Ioset
100%Ioset
10%Ioset > Iomin (default setting is 60%)
Iomin
60%Ioset
100%Ioset
10%Ioset ≤Iomin (default setting is 60%)
Protection
Current Floor
Notes
Over Temperature Protection
Decreases output current, returning to normal after over temperature is removed.
Short Circuit Protection
Auto Recovery. No damage will occur when any output is short circuited. The output
shall return to normal when the fault condition is removed.
Over Voltage Protection
Limits output voltage at no load and in case the normal voltage limit fails.
8 / 11
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-096SxxxBVA
96W Programmable IP67 Driver with DALI
Rev. B
Dimming
DALI Dimming
The recommended implementation of the dimming control is provided below.
Implementation: DALI Dimming
Time Dimming
Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self AdaptingPercentage and Traditional Timer.
Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two
days (if difference
很抱歉,暂时无法提供与“EUD-096S210BVA”相匹配的价格&库存,您可以联系我们找货
免费人工找货