EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
Features
•
Ultra High Efficiency (Up to 93.5%)
•
Full Power at Wide Output Current Range (Constant Power)
•
Thermal Sensing and Protection for LED Module
•
DALI/AC Dim/Timer Dimmable (3 Timer Modes)
•
Dim-to-Off with Standby Power ≤ 0.5 W
•
Always-on Auxiliary Power: 12Vdc, 200mA (Transient Peak
Current up to 400mA)
•
Output Lumen Compensation
•
Long Lifetime Over 100k Hours at 75°C Case Temperature
•
Input Surge Protection: DM 6 kV, CM 10 kV
•
All-Around Protection: OVP, SCP, OTP
•
IP20 Design and Suitable for Outdoor Applications in
Luminaires with IP>54
•
SELV Output
•
Suitable for Luminaires with Protection Class I and II
•
Complies with Zhaga Interface Specification Book 13
•
7 Years Warranty
Description
The EBS-120SxxxBTE series is a 120W, constant-current, programmable LED driver that operates from 176305 Vac input with excellent power factor. Created for many lighting applications including street, tunnel and
high bay, it provides a dim-to-off mode with low standby power. The high efficiency of these drivers and better
thermal design enable them to run cooler, significantly improving reliability and extending product life. To ensure
trouble-free operation, protection is provided against input surge, output over voltage, short circuit, and over
temperature of both the driver and the external LED array.
Models
Adjustable
Output
Current
Range
Full-Power
Current
Range(1)
Default
Output
Current
Input
Voltage
Range(2)
Output
Voltage
Range
Max.
Typical
Output Efficiency
Power
(3)
176~305Vac
86~240Vdc 120 W
190~250Vdc
176~305Vac
70-1050mA 700-1050mA 700 mA
57~171Vdc 120 W
190~250Vdc
176~305Vac
105-1500mA 1050-1500mA 1050 mA
40~114Vdc 120 W
190~250Vdc
50-700mA
500-700mA
530 mA
Power
Factor
(3)
Model Number
93.5%
0.98
EBS-120S070BTE
93.5%
0.98
EBS-120S105BTE
93.5%
0.98
EBS-120S150BTE
(4)
Notes: (1) Output current range with constant power at 120W
(2) Certified voltage range: 200-240Vac or 190-250Vdc (except CCC and KS)
(3) Measured at full load and 220Vac input (see below “General Specifications” for details).
(4) SELV Output.
1 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
I-V Operating Area
EBS-120S070BTE
EBS-120S105BTE
EBS-120S150BTE
Input Specifications
Parameter
Min.
Typ.
Max.
176 Vac
-
305 Vac
Input Frequency
47 Hz
-
63 Hz
Leakage Current
-
-
0.70 mA
Input AC Current
-
-
0.67 A
2
-
-
1.30 A s
0.90
-
-
THD
-
-
20%
THD
-
-
10%
Input Voltage
Inrush Current(I t)
PF
2
Notes
190~250 Vdc
IEC60598-1; 240Vac/ 60Hz
Measured at full load and 220 Vac input.
At 220Vac input, 25°C cold start,
duration=1.03 ms, 10%Ipk-10%Ipk. See
Inrush Current Waveform for the details.
At 200-240Vac, 50-60Hz, 60%-100% Load
(72-120W)
At 220-240Vac, 50-60Hz, 70%-100% Load
(84-120W)
2 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
Output Specifications
Parameter
Min.
Typ.
Max.
-5%Ioset
-
5%Ioset
50 mA
70 mA
105 mA
-
700 mA
1050 mA
1500 mA
500 mA
700 mA
1050 mA
-
700 mA
1050 mA
1500 mA
-
5%Iomax
10%Iomax
-
2%Iomax
-
Startup Overshoot Current
-
-
10%Iomax
No Load Output Voltage
EBS-120S070BTE
EBS-120S105BTE
EBS-120S150BTE
-
-
270 V
190 V
120 V
Line Regulation
-
-
±0.5%
Load Regulation
-
-
±1.5%
Turn-on Delay Time
-
-
0.5 s
Temperature Coefficient of
Ioset
-
0.03%/°C
-
12V Auxiliary Output Voltage
10.8 V
12 V
13.2 V
12V Auxiliary Output Source
Current
0 mA
-
200 mA
Return terminal is “Return“
-
-
400 mA
400mA peak for a maximum duration of
300ms in a 2s period during which time the
average should not exceed 200mA.
Output Current Tolerance
Output Current Setting(Ioset)
Range
EBS-120S070BTE
EBS-120S105BTE
EBS-120S150BTE
Output Current Setting Range
with Constant Power
EBS-120S070BTE
EBS-120S105BTE
EBS-120S150BTE
Total Output Current Ripple
(pk-pk)
Output Current Ripple at
< 200 Hz (pk-pk)
12V Auxiliary Output
Transient Peak Current
Notes
At full load condition
At full load condition, 20 MHz BW
At full load condition. Only this component
of ripple is associated with visible flicker.
At full load condition
Measured at full load
Measured at 220Vac input, 60%-100% Load
Case temperature = 0°C ~Tc max
Note: All specifications are typical at 25°C unless otherwise stated.
General Specifications
Parameter
Min.
Typ.
Max.
91.5%
89.5%
93.5%
91.5%
-
91.5%
89.5%
93.5%
91.5%
-
91.5%
89.5%
93.5%
91.5%
-
Standby power
-
-
0.5 W
MTBF
-
216,000
Hours
-
Efficiency at 220 Vac input:
EBS-120S070BTE
Io= 500 mA
Io= 700 mA
EBS-120S105BTE
Io= 700 mA
Io=1050 mA
EBS-120S150BTE
Io=1050 mA
Io=1500 mA
Notes
Measured at full load and steady-state
temperature in 25°C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 230Vac/50Hz; Dimming off
Measured at 220Vac input, 80% Load and
25°C ambient temperature (MIL-HDBK217F)
3 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
General Specifications (Continued)
Parameter
Lifetime
Operating Case Temperature
for Safety Tc_s
Min.
Typ.
Max.
-
120,000
Hours
-
-40°C
-
+90°C
Measured at 220Vac input, 80%Load and
75°C case temperature; See lifetime vs. Tc
curve for the details
Operating Case Temperature
for Warranty Tc_w
-40°C
-
+75°C
Storage Temperature
-40°C
-
+85°C
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Net Weight
Notes
Case temperature for 7 years warranty.
Please see Inventronics Warranty Statement
for complete details.
No condensation.
Humidity: 5%RH to 85%RH;
No condensation.
6.50 × 2.76 × 1.56
165 × 70 × 39.5
-
520 g
-
Note: All specifications are typical at 25°C unless otherwise stated.
Dimming Specifications
DALI
Parameter
Min.
Typ.
Max.
DA, DA High Level
9.5 V
16 V
22.5 V
DA, DA Low Level
-6.5 V
0V
6.5 V
DA, DA Current
0 mA
-
2 mA
Start Input Voltage
180 Vac
-
250 Vac
Start Output Level
30%
-
100%
Stop Input Voltage
160 Vac
-
230 Vac
Stop Output Level
30%
-
85%
20 Vac
-
-
-
1 Vac
-
-
1%
-
10%Ioset
-
Ioset
50 mA
70 mA
105 mA
-
Ioset
AC Dim Gap between Start
and Stop Input
Voltage
Increment of Start
and Stop Input
Voltage
Increment of Start
and Stop Output
Level
EBS-120S070BTE
EBS-120S105BTE
Dimming EBS-120S150BTE
Output
Range EBS-120S070BTE
EBS-120S105BTE
EBS-120S150BTE
Notes
Default is 220 Vac
Default is 100%
Default is 170 Vac
Default is 30%
500 mA ≤ Ioset ≤ 700 mA
700 mA ≤ Ioset ≤ 1050 mA
1050 mA ≤ Ioset ≤ 1500 mA
50 mA ≤ Ioset < 500 mA
70 mA ≤ Ioset < 700 mA
105 mA ≤ Ioset < 1050 mA
Note: All specifications are typical at 25 °C unless stated otherwise.
4 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
Safety &EMC Compliance
Safety Category
ENEC & TUV & CE
CCC
Standard
EN 61347-1, EN61347-2-13
GB 19510.1, GB 19510.14
KS
KS C 7655
Performance
ENEC
Standard
EN 62384
EMI Standards
EN 55015
(1)
Notes
Conducted emission Test &Radiated emission Test
EN 61000-3-2
Harmonic current emissions
EN 61000-3-3
Voltage fluctuations & flicker
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4
Electrical Fast Transient / Burst-EFT
EN 61000-4-5
Surge Immunity Test: AC Power Line: Differential Mode 6 kV, Common Mode 8 kV
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8
Power Frequency Magnetic Field Test
EN 61000-4-11
Voltage Dips
EN 61547
Surge Immunity Test: AC Power Line: Differential Mode 6 kV, Common Mode 10 kV
Electromagnetic Immunity Requirements Applies to Lighting Equipment
DALI Standards
DALI
Notes
(2)
IEC62386-101,102 & part of 207
Notes: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it
depends also on the other devices connected to the driver and on the fixture itself.
(2) Optional Commands Implemented: 242 (query short circuit), 243 (query open circuit).
5 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
Rev. D
120W Class I/II Programmable IP20 Driver with DALI
Lifetime vs. Case Temperature
Inrush Current Waveform
Efficiency vs. Load
EBS-120S070BTE(Io=500mA)
EBS-120S070BTE(Io=700mA)
6 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
Rev. D
120W Class I/II Programmable IP20 Driver with DALI
EBS-120S105BTE(Io=700mA)
EBS-120S105BTE(Io=1050mA)
EBS-120S150BTE(Io=1050mA)
EBS-120S150BTE(Io=1500mA)
Power Factor
7 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
Total Harmonic Distortion
Protection Functions
Parameter
External
Thermal
Protection
NTC
Min.
Typ.
Max.
Notes
R1
-
7.81 kOhm
-
R2
-
4.16 kOhm
-
Protection
Current Floor
10%Ioset
60%Ioset
100%Ioset
10%Ioset>Iomin (default setting is 60%)
Iomin
60%Ioset
100%Ioset
10%Ioset≤Iomin (default setting is 60%)
When R_NTC falls below R1, External Thermal
Protection is triggered, reducing output current
until R2 is reached.
When R_NTC is less than R2, output current is
reduced to the programmed “Protection
Current Floor.”
Over Temperature Protection
Decreases output current, returning to normal after over temperature is removed.
Short Circuit Protection
Auto Recovery. No damage will occur when any output is short circuited. The output
shall return to normal when the fault condition is removed.
Over Voltage Protection
Limits output voltage at no load and in case the normal voltage limit fails.
Dimming
DALI Dimming
The recommended implementation of the dimming control is provided below.
8 / 14
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EBS-120SxxxBTE
120W Class I/II Programmable IP20 Driver with DALI
Rev. D
Implementation: DALI Dimming
Time Dimming
Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self AdaptingPercentage and Traditional Timer.
• Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two
days (if difference
很抱歉,暂时无法提供与“EBS-120S070BTE”相匹配的价格&库存,您可以联系我们找货
免费人工找货