EUK-150S350DV

EUK-150S350DV

  • 厂商:

    INVENTRONICS(英飞特)

  • 封装:

  • 描述:

  • 数据手册
  • 价格&库存
EUK-150S350DV 数据手册
EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Features  High Efficiency (Up to 93%)  Full Power at Wide Output Current Range (Constant Power)  Isolated 0-10V/10V PWM Dimmable (DV models) 3-Timer-Modes Dimmable (TV models)  Input Surge Protection: 6kV line-line, 10kV line-earth  All-Around Protection: OVP, SCP, OTP  Waterproof (IP67)  SELV Output  Suitable for Independent Use  5 Years Warranty Description The EUK-150SxxxDV(TV) series is a 150W, constant-current, programmable IP67 LED driver that operates from 90-305Vac input with excellent power factor. It is created for many lighting applications including high bay, tunnel and roadway. The high efficiency of these drivers and compact metal case enables them to run cooler, significantly improving reliability and extending product life. To ensure trouble-free operation, protection is provided against input surge, output over voltage, short circuit, and over temperature. Models Adjustable Output Current Range Full-Power Current Range (1) Default Output Current 70-1050mA 700-1050mA 700 mA 105-1500mA 1050-1500mA 1050 mA 140-2100mA 1400-2100mA 1400 mA 245-3500mA 2450-3500mA 3150 mA 385-5600mA 3850-5600mA 4200 mA Input Voltage Range(2) 90~305 Vac/ 127~250 Vdc 90~305 Vac/ 127~250 Vdc 90~305 Vac/ 127~250 Vdc 90~305 Vac/ 127~250 Vdc 90~305 Vac/ 127~250 Vdc Output Voltage Range Max. Typical Power Factor Output Efficiency 120Vac 220Vac Power (3) Model Number 75~214 Vdc 150W 93.0% 0.99 0.96 EUK-150S105DV(TV) 50~143Vdc 150W 93.0% 0.99 0.96 EUK-150S150DV(TV) 38~107 Vdc 150W 92.5% 0.99 0.96 EUK-150S210DV(TV)(4) 22 ~ 61 Vdc 150W 91.5% 0.99 0.96 EUK-150S350DV(TV)(4) 14 ~ 39 Vdc 150W 90.5% 0.99 0.96 EUK-150S560DV(TV)(4) Notes: (1) Output current range with constant power at 150W (2) Certified voltage range: 100-240Vac or 127-250Vdc (except CCC, PSE, KS and BIS) (3) Measured at 100% load and 220Vac input (see below “General Specifications” for details). (4) SELV Output. (5) For BIS models add suffix -3000. 1 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D I-V Operation Area EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) 2 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Input Specifications Parameter Min. Typ. Max. Input Voltage 90 Vac - 305 Vac Input Frequency 47 Hz - 63 Hz Leakage Current - - 0.70 mA - - 1.60 A Measured at 100% load and 120 Vac input. - - 0.90A Measured at 100% load and 220 Vac input. - - 2.60A s 0.9 - - THD - - 20% THD - - 10% At 220-240Vac, 50-60Hz, 75%-100% Load (112.5-150W) Min. Typ. Max. Notes -5%Ioset - 5%Ioset 70 mA 105 mA 140 mA 245 mA 385 mA - 1050 mA 1500 mA 2100 mA 3500 mA 5600 mA 700 mA 1050 mA 1400 mA 2450 mA 3850 mA - 1050 mA 1500 mA 2100 mA 3500 mA 5600 mA - 5%Iomax 10%Iomax - 2%Iomax - 100% load Startup Overshoot Current - - 10%Iomax 100% load No Load Output Voltage EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) - - 240 V 160 V 120 V 80 V 50 V Line Regulation - - ±0.5% Load Regulation - - ±1.5% - - 1.0 s - - 0.5 s Input AC Current 2 Inrush Current(I t) PF 2 Notes 127~250 Vdc IEC60598-1; 240Vac/ 60Hz At 220Vac input, 25C cold start, duration=456μs, 10%Ipk-10%Ipk. See Inrush Current Waveform for the details. At 100-240Vac, 50-60Hz, 60%-100% Load (90-150W) Output Specifications Parameter Output Current Tolerance Output Current Setting(Ioset) Range EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) Output Current Setting Range with Constant Power EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) Total Output Current Ripple (pk-pk) Output Current Ripple at < 200 Hz (pk-pk) Turn-on Delay Time 100% load 100% load. 20 MHz BW 100% load Measured at 120Vac input, 60%-100% Load Measured at 220Vac input, 60%-100% Load 3 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Output Specifications (Continued) Parameter Temperature Coefficient of Ioset Min. Typ. Max. - 0.03%/C - Notes Case temperature = 0C ~Tc max Note: All specifications are typical at 25C unless otherwise stated. General Specifications Parameter Efficiency at 120 Vac input: EUK-150S105DV(TV) Io= 700 mA Io=1050 mA EUK-150S150DV(TV) Io=1050 mA Io=1500 mA EUK-150S210DV(TV) Io=1400 mA Io=2100 mA EUK-150S350DV(TV) Io=2450 mA Io=3500 mA EUK-150S560DV(TV) Io=3850 mA Io=5600 mA Efficiency at 220 Vac input: EUK-150S105DV(TV) Io= 700 mA Io=1050 mA EUK-150S150DV(TV) Io=1050 mA Io=1500 mA EUK-150S210DV(TV) Io=1400 mA Io=2100 mA EUK-150S350DV(TV) Io=2450 mA Io=3500 mA EUK-150S560DV(TV) Io=3850 mA Io=5600 mA Efficiency at 277 Vac input: EUK-150S105DV(TV) Io= 700 mA Io=1050 mA EUK-150S150DV(TV) Io=1050 mA Io=1500 mA EUK-150S210DV(TV) Io=1400 mA Io=2100 mA EUK-150S350DV(TV) Io=2450 mA Io=3500 mA EUK-150S560DV(TV) Io=3850 mA Io=5600 mA MTBF Min. Typ. Max. 89.0% 87.5% 91.0% 89.5% - 89.0% 87.5% 91.0% 89.5% - 88.5% 86.5% 90.5% 88.5% - 87.0% 86.0% 89.0% 88.0% - 86.0% 84.5% 88.0% 86.5% - 91.0% 90.0% 93.0% 92.0% - 91.0% 90.0% 93.0% 92.0% - 90.5% 89.0% 92.5% 91.0% - 89.5% 88.5% 91.5% 90.5% - 88.5% 87.0% 90.5% 89.0% - 91.5% 90.5% 93.5% 92.5% - 91.5% 90.0% 93.5% 92.0% - 90.5% 89.0% 92.5% 91.0% - 90.0% 88.5% 92.0% 90.5% - 88.5% 87.0% 90.5% 89.0% 271,000 Hours - - - Notes Measured at 100% load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Measured at 100% load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Measured at 100% load and steady-state temperature in 25C ambient; (Efficiency will be about 2.0% lower if measured immediately after startup.) Measured at 220Vac input, 80%Load and 25C ambient temperature 4 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D General Specifications (Continued) Parameter Lifetime Operating Case Temperature for Safety Tc_s Operating Case Temperature for Warranty Tc_w Storage Temperature Min. Typ. Max. Notes - 81,000 Hours - Measured at 220Vac input, 80%Load and 70C case temperature; See lifetime vs. Tc curve for the details -40°C - +85°C -40°C - +75C -40°C - +85°C Case temperature for 5 years warranty Humidity: 5%RH to 100%RH Dimensions Inches (L × W × H) Millimeters (L × W × H) With mounting ear 7.56 × 2.66 × 1.44 192 × 67.5 × 36.5 6.74 × 2.66 × 1.44 171 × 67.5 × 36.5 Net Weight - 890 g - Note: All specifications are typical at 25C unless otherwise stated. Dimming Specifications Parameter DV Models TV Models Min. Typ. Max. -20 V - 20 V 200 uA 300 uA 450 uA 0V - 10 V PWM_in High Level - 10V - PWM_in Low Level - 0V - PWM_in Frequency Range 200 Hz - 2 KHz PWM_in Duty Cycle 0% - 100% Dimming Level 10% - 100% Hold Time 0 Hours - 18 Hours Fade Time 0 Minutes - 60 Minutes 1 - 6 Absolute Maximum Voltage on the Vdim (+) Pin Source Current on Vdim (+)Pin Recommended Dimming Range for 010V Dimming Step Dimming Output Range EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) EUK-150S105DV(TV) EUK-150S150DV(TV) EUK-150S210DV(TV) EUK-150S350DV(TV) EUK-150S560DV(TV) 10%Ioset - Ioset 70 mA 105 mA 140 mA 245 mA 385 mA - Ioset Notes Vdim(+) = 0 V Default is Traditional Timer. Dimming mode set to Self-AdaptingMidnight or Self Adapting-Percentage in PC interface. 700 mA ≤ Ioset ≤ 1050 mA 1050 mA ≤ Ioset ≤ 1500 mA 1400 mA ≤ Ioset ≤ 2100 mA 2450 mA ≤ Ioset ≤ 3500 mA 3850 mA ≤ Ioset ≤ 5600 mA 70 mA ≤ Ioset < 700 mA 105 mA ≤ Ioset < 1050 mA 140 mA ≤ Ioset < 1400 mA 245 mA ≤ Ioset < 2450 mA 385 mA ≤ Ioset < 3850 mA 5 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Safety &EMC Compliance Safety Category Standard ENEC & TUV & CE CCC EN 61347-1, EN61347-2-13 GB 19510.1, GB 19510.14 KS KS C 7655 PSE J 61347-1(H20), J 61347-2-13(H21) BIS IS 15885(Part2/Sec13) EAC IEC 61347-1, IEC 61347-2-13 EMI Standards EN 55015/GB 17743 Notes (1) Conducted emission Test &Radiated emission Test EN 61000-3-2/GB 17625.1 Harmonic current emissions EN 61000-3-3 Voltage fluctuations & flicker EMS Standards Notes EN 61000-4-2 Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge EN 61000-4-3 Radio-Frequency Electromagnetic Field Susceptibility Test-RS EN 61000-4-4 Electrical Fast Transient / Burst-EFT EN 61000-4-5 Surge Immunity Test: AC Power Line: line to line 6 kV, line to earth 10 kV EN 61000-4-6 Conducted Radio Frequency Disturbances Test-CS EN 61000-4-8 Power Frequency Magnetic Field Test EN 61000-4-11 Voltage Dips EN 61547 (2) Electromagnetic Immunity Requirements Applies To Lighting Equipment Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it depends also on the other devices connected to the driver and on the fixture itself. (2) To perform electric strength (hi-pot) testing, the “GDT ground disconnect” (nut and metal lock sheet) on the driver end-cap should be removed temporarily to prevent the internal gas discharge tube from conducting (as allowed by IEC 60598-1 Clause 10.2). After testing is completed, these items must be reinstalled to restore lineto-earth surge protection and secure the end cap. 6 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Derating Lifetime vs. Case Temperature Inrush Current Waveform 7 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Efficiency vs. Load EUK-150S105DV(TV)(Io=700mA) EUK-150S105DV(TV)(Io=1050mA) EUK-150S150DV(TV)(Io=1050mA) EUK-150S150DV(TV)(Io=1500mA) EUK-150S210DV(TV)(Io=1400mA) EUK-150S210DV(TV)(Io=2100mA) 8 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D EUK-150S350DV(TV)(Io=2450mA) EUK-150S350DV(TV)(Io=3500mA) EUK-150S560DV(TV)(Io=3850mA) EUK-150S560DV(TV)(Io=5600mA) Power Factor 9 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV) 150W Programmable IP67 Driver Rev. D Total Harmonic Distortion Protection Functions Parameter Notes Over Temperature Protection Decreases output current, returning to normal after over temperature is removed. Short Circuit Protection Auto Recovery. No damage will occur when any output is short circuited. The output shall return to normal when the fault condition is removed. Over Voltage Protection Limits output voltage at no load and in case the normal voltage limit fails. Dimming  0-10V Dimming (Only DV models) The recommended implementation of the dimming control is provided below. Implementation 1 Notes: 1. The dimmer can also be replaced by an active 0-10V voltage source signal or passive components like resistors and zener. 2. If 0-10V dimming is not used, Dim + should be open. 10 / 14 Specifications are subject to changes without notice. www.inventronics-co.com Tel: 86-571-56565800 Fax: 86-571-86601139 sales@inventronics-co.com EUK-150SxxxDV(TV)  150W Programmable IP67 Driver Rev. D 10V PWM Dimming (Only DV models) The recommended implementation of the dimming control is provided below. Implementation 2 Notes: If PWM dimming is not used, Dim + should be open.  Time Dimming (Only TV models) Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self AdaptingPercentage and Traditional Timer.  Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two days (if difference
EUK-150S350DV 价格&库存

很抱歉,暂时无法提供与“EUK-150S350DV”相匹配的价格&库存,您可以联系我们找货

免费人工找货