EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Features
Ultra High Efficiency (Up to 95.0%)
Full Power at Wide Output Current Range (Constant Power)
Thermal Sensing and Protection for LED Module
0-10V/PWM/Timer Dimmable (3 Timer Modes)
Dim-to-Off with Standby Power ≤ 0.5 W
Always-on Auxiliary Power: 12Vdc, 200mA
Output Lumen Compensation
Input Surge Protection: 6kV line-line, 10kV line-earth
All-Around Protection: OVP, SCP, OTP
Waterproof (IP67) and UL Dry / Damp / Wet Location
SELV Output
TYPE HL, for use in a Class I, Division 2 hazardous
(Classified) location
7 Years Warranty
Description
The EUD-600SxxxDT series is a 600W, constant-current, programmable LED driver that operates from 90-305
Vac input with excellent power factor. Created for many lighting applications including high bay, high mast,
aquaculture and sports, it provides a dim-to-off mode with low standby power. The high efficiency of these
drivers and compact metal case enables them to run cooler, significantly improving reliability and extending
product life. To ensure trouble-free operation, protection is provided against input surge, output over voltage,
short circuit, and over temperature.
Models
Adjustable
Full-Power Default
Output
Current Output
Current
Range(1) Current
Range
0.11–1.40A 1.10–1.40A
1.4 A
0.136-1.70A 1.36–1.70A
1.7A
0.168–2.10A 1.68–2.10A
2.1A
0.224-2.80A 2.24–2.80A
2.8 A
0.336-4.20A 3.36–4.20A
4.2 A
0.448-5.60A 4.48–5.60A
5.6 A
0.592-7.40A 5.92–7.40A
7.0 A
0.784-9.80A 7.84–9.80A
9.8 A
1.0 – 12.5 A 10 – 12.5 A 12.5 A
Input
Voltage
Range(2)
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
90~305Vac/
127~300Vdc
Output
Voltage
Range
Power Factor
Max.
Typical
Output Efficiency
Power
(3)
120Vac 220Vac
Model Number
214 ~ 545Vdc 600 W
95.0%
0.99
0.96
EUD-600S140DT
176 ~ 441Vdc
600 W
94.0%
0.96
0.95
EUD-600S170DT
143 ~ 357Vdc 600 W
94.5%
0.99
0.96
EUD-600S210DT
108 ~ 268Vdc 600 W
95.0%
0.99
0.96
EUD-600S280DT
72 ~ 178Vdc
600 W
94.5%
0.99
0.96
EUD-600S420DT
54 ~ 134Vdc
600 W
94.5%
0.99
0.96
EUD-600S560DT
41 ~ 101Vdc
600 W
94.0%
0.99
0.96
EUD-600S740DT
(4)
31 ~ 76Vdc
600 W
94.0%
0.99
0.96
EUD-600S980DT
(4)
24 ~ 60Vdc
600 W
94.0%
0.99
0.96
EUD-600S12ADT(4)
1 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Notes: (1) Output current range with constant power at 600W
(2) Certified input voltage range: UL, FCC 100-277Vac or 127-300Vdc; otherwise 100-240Vac or 127-250Vdc
(3) Measured at 100% load and 220Vac input (see below “General Specifications” for details).
(4) SELV Output
I-V Operating Area
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
330
(10%Ioset,600/Ioset)
220
oa
d
(2800,214)
(Ioset,600/Ioset)
Lo
%
60
165
ad
Output Voltage(V)
(2240,268)
10
0%
L
(1344,268)
275 (224,268)
(2800,129)
110
(280,108)
55
(Ioset,108)
(2800,108)
Good Performance Area
Allowed Operating Area
Programmed Operating Area
550
2200
0
0
1100
1650
2750
3300
Output Current (mA)
Note: 2240mA
Ioset
2800mA
2 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
%
60
ad
Lo
3 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Input Specifications
Parameter
Min.
Typ.
Max.
Input Voltage
90 Vac
-
305 Vac
Input Frequency
47 Hz
-
63 Hz
-
-
0.75 MIU
-
-
0.70 mA
-
-
6.0 A
-
-
3.5 A
-
-
4.70 A s
0.90
-
-
THD
-
-
20%
THD
-
-
10%
At 220-240Vac, 50-60Hz, 75%-100% Load
(450 - 600W)
Min.
Typ.
Max.
Notes
-5%Ioset
-
5%Ioset
110 mA
136 mA
168mA
224 mA
336 mA
448 mA
592 mA
784 mA
1000 mA
-
1400 mA
1700 mA
2100 mA
2800 mA
4200 mA
5600 mA
7400 mA
9800 mA
12500 mA
1100 mA
1360 mA
1680 mA
2240 mA
3360 mA
4480 mA
5920 mA
7840 mA
10000 mA
-
1400 mA
1700 mA
2100 mA
2800 mA
4200 mA
5600 mA
7400 mA
9800 mA
12500 mA
-
5%Iomax
10%Iomax
-
2%Iomax
-
100% load
-
-
10%Iomax
100% load
Leakage Current
Input AC Current
2
Inrush Current(I t)
PF
2
Notes
127-300Vdc
UL8750; 277Vac/ 60Hz, grounding
effectively
IEC60598-1; 240Vac/ 60Hz, grounding
effectively
Measured at 100% load and 120 Vac
input.
Measured at 100% load and 220 Vac
input.
At 220Vac input, 25℃ cold start,
duration=7.64 ms, 10%Ipk-10%Ipk. See
Inrush Current Waveform for the details.
At 100-277Vac, 50-60Hz, 60%-100% Load
(360 - 600W)
Output Specifications
Parameter
Output Current Tolerance
Output Current Setting(Ioset)
Range
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
Output Current Setting Range
with Constant Power
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
Total Output Current Ripple
(pk-pk)
Output Current Ripple at
< 200 Hz (pk-pk)
Startup Overshoot Current
100% load
100% load, 20 MHz BW
4 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Output Specifications (Continued)
Parameter
Min.
Typ.
Max.
No Load Output Voltage
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
-
600 V
475 V
410 V
290 V
190 V
150 V
118 V
87 V
70 V
605V
480 V
415 V
295 V
200 V
155 V
120 V
95 V
80 V
Line Regulation
-
-
±0.5%
Load Regulation
-
-
±1.5%
-
-
1.0 s
-
-
0.5 s
-
0.03%/C
-
12V Auxiliary Output Voltage
10.8 V
12 V
13.2 V
12V Auxiliary Output Source
Current
0 mA
-
200 mA
Turn-on Delay Time
Temperature Coefficient of
Ioset
Notes
100% load
Measured at 120Vac input, 60%-100%
Load
Measured at 220Vac input, 60%-100%
Load
Case temperature = 0C ~Tc max
Return terminal is “Dim−“
Note: All specifications are typical at 25C unless otherwise stated.
General Specifications
Parameter
Efficiency at 120 Vac input:
EUD-600S140DT
lo= 1100 mA
lo= 1400 mA
EUD-600S170DT
Io= 1360 mA
Io= 1700 mA
EUD-600S210DT
lo= 1680 mA
lo= 2100 mA
EUD-600S280DT
Io= 2240 mA
Io= 2800 mA
EUD-600S420DT
Io= 3360 mA
Io= 4200 mA
EUD-600S560DT
Io= 4480 mA
Io= 5600 mA
EUD-600S740DT
Io= 5920 mA
Io= 7400 mA
EUD-600S980DT
Io= 7840 mA
Io= 9800 mA
EUD-600S12ADT
lo= 10000 mA
lo= 12500 mA
Min.
Typ.
Max.
90.5%
90.0%
92.5%
92.0%
-
90.0%
89.5%
92.0%
91.5%
-
90.0%
89.5%
92.0%
91.5%
-
91.0%
90.0%
93.0%
92.0%
-
90.5%
89.5%
92.5%
91.5%
-
90.0%
89.5%
92.0%
91.5%
-
89.5%
89.0%
91.5%
91.0%
-
90.0%
89.5%
92.0%
91.5%
-
89.5%
89.0%
91.5%
91.0%
-
Notes
Measured at100% load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
5 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
General Specifications (Continued)
Parameter
Efficiency at 220 Vac input:
EUD-600S140DT
lo= 1100 mA
lo= 1400 mA
EUD-600S170DT
Io= 1360 mA
Io= 1700 mA
EUD-600S210DT
lo= 1680 mA
lo= 2100 mA
EUD-600S280DT
Io= 2240 mA
Io= 2800 mA
EUD-600S420DT
Io= 3360 mA
Io= 4200 mA
EUD-600S560DT
Io= 4480 mA
Io= 5600 mA
EUD-600S740DT
Io= 5920 mA
Io= 7400 mA
EUD-600S980DT
Io= 7840 mA
Io= 9800 mA
EUD-600S12ADT
lo= 10000 mA
lo= 12500 mA
Efficiency at 277 Vac input:
EUD-600S140DT
lo= 1100 mA
lo= 1400 mA
EUD-600S170DT
Io= 1360 mA
Io= 1700 mA
EUD-600S210DT
lo= 1680 mA
lo= 2100 mA
EUD-600S280DT
Io= 2240 mA
Io= 2800 mA
EUD-600S420DT
Io= 3360 mA
Io= 4200 mA
EUD-600S560DT
Io= 4480 mA
Io= 5600 mA
EUD-600S740DT
Io= 5920 mA
Io= 7400 mA
EUD-600S980DT
Io= 7840 mA
Io= 9800 mA
EUD-600S12ADT
lo= 10000 mA
lo= 12500 mA
Min.
Typ.
Max.
92.5%
92.0%
94.5%
94.0%
-
92.0%
92.0%
94.0%
94.0%
-
92.5%
92.0%
94.5%
94.0%
-
93.0%
92.5%
95.0%
94.5%
-
92.5%
92.0%
94.5%
94.0%
-
92.5%
92.0%
94.5%
94.0%
-
92.0%
91.5%
94.0%
93.5%
-
92.0%
91.0%
94.0%
93.0%
-
91.5%
91.0%
93.5%
93.0%
-
93.0%
92.5%
95.0%
94.5%
-
92.5%
92.0%
94.5%
94.0%
-
92.5%
92.0%
94.5%
94.0%
-
93.0%
92.5%
95.0%
94.5%
-
93.0%
92.0%
95.0%
94.0%
-
93.0%
92.5%
95.0%
94.5%
-
92.5%
91.5%
94.5%
93.5%
-
92.5%
91.5%
94.5%
93.5%
-
92.0%
91.5%
94.0%
93.5%
-
Notes
Measured at 100% load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
Measured at 100% load and steady-state
temperature in 25C ambient;
(Efficiency will be about 2.0% lower if
measured immediately after startup.)
6 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
General Specifications (Continued)
Parameter
Min.
Typ.
Max.
Standby power
-
-
0.5 W
MTBF
-
200,000
Hours
-
Lifetime
-
90,000
Hours
-
Operating Case Temperature
for Safety Tc_s
-40°C
-
+89C
Operating Case Temperature
for Warranty Tc_w
-40°C
-
+75C
Case temperature for 7 years warranty.
Please see Inventronics Warranty
Statement for complete details.
Storage Temperature
-40°C
-
+85°C
Humidity: 5%RH to 100%RH
Dimensions
Inches (L × W × H)
Millimeters (L × W × H)
Net Weight
Measured at 230Vac/50Hz; Dimming off
Measured at 220Vac input, 80%Load and
25C ambient temperature (MIL-HDBK217F)
Measured at 220Vac input, 80%Load and
70C case temperature; See lifetime vs. Tc
curve for the details
With mounting ear
10.83× 5.67 × 1.91
275 × 144 × 48.5
9.84 × 5.67 × 1.91
250 × 144 × 48.5
-
Notes
3515 g
-
Note: All specifications are typical at 25C unless otherwise stated.
Dimming Specifications
Parameter
Absolute Maximum Voltage
on the Vdim (+) Pin
Source Current on Vdim (+)Pin
Dimming
Output
Range
Min.
Typ.
Max.
-20 V
-
20 V
200 uA
300 uA
450 uA
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
10%Ioset
-
Ioset
EUD-600S140DT
EUD-600S170DT
EUD-600S210DT
EUD-600S280DT
EUD-600S420DT
EUD-600S560DT
EUD-600S740DT
EUD-600S980DT
EUD-600S12ADT
110 mA
136 mA
168 mA
224 mA
336 mA
448 mA
592 mA
784 mA
1000 mA
-
Ioset
Notes
Vdim(+) = 0 V
1100 mA ≤ Ioset ≤ 1400 mA
1360 mA ≤ Ioset ≤ 1700 mA
1680 mA ≤ Ioset ≤ 2100 mA
2240 mA ≤ Ioset ≤ 2800 mA
3360 mA ≤ Ioset ≤ 4200 mA
4480 mA ≤ Ioset ≤ 5600 mA
5920 mA ≤ Ioset ≤7400 mA
7840 mA ≤ Ioset ≤ 9800 mA
10000 mA ≤ Ioset ≤ 12500 mA
110 mA ≤ Ioset < 1100 mA
136 mA ≤ Ioset < 1360 mA
168 mA ≤ Ioset <1680 mA
224 mA ≤ Ioset< 2240 mA
336 mA ≤ Ioset < 3360 mA
448 mA ≤ Ioset < 4480 mA
592 mA ≤ Ioset < 5920 mA
784 mA ≤ Ioset < 7840 mA
1000 mA ≤ Ioset < 10000 mA
7 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Dimming Specifications (Continued)
Parameter
Min.
Typ.
Max.
0V
-
10 V
Dim off Voltage
0.35 V
0.5 V
0.65 V
Dim on Voltage
0.55 V
0.7 V
0.85 V
-
0.2 V
-
PWM_in High Level
3V
-
10 V
PWM_in Low Level
-0.3 V
-
0.6 V
PWM_in Frequency Range
200 Hz
-
3 KHz
1%
-
99%
3%
5%
8%
5%
7%
10%
92%
95%
97%
90%
93%
95%
-
2%
-
Recommended Dimming
Input Range
Hysteresis
PWM_in Duty Cycle
PWM Dimming off (Positive
Logic)
PWM Dimming on (Positive
Logic)
PWM Dimming off ( Negative
Logic)
PWM Dimming on ( Negative
Logic)
Hysteresis
Notes
Default 0-10V dimming mode.
Dimming mode set to PWM in PC interface.
Note: All specifications are typical at 25 C unless stated otherwise.
Safety &EMC Compliance
Safety Category
UL/CUL
Standard
UL8750,CAN/CSA-C22.2 No. 250.13
CE
EN 61347-1, EN61347-2-13
EMI Standards
(1)
EN 55015
Notes
Conducted emission Test &Radiated emission Test
EN 61000-3-2
Harmonic current emissions
EN 61000-3-3
Voltage fluctuations & flicker
ANSI C63.4 Class B
(1)
FCC Part 15
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: [1] this device may not cause harmful interference, and [2] this
device must accept any interference received, including interference that may cause
undesired Operation.
EMS Standards
Notes
EN 61000-4-2
Electrostatic Discharge (ESD): 8 kV air discharge, 4 kV contact discharge
EN 61000-4-3
Radio-Frequency Electromagnetic Field Susceptibility Test-RS
EN 61000-4-4
Electrical Fast Transient / Burst-EFT
EN 61000-4-5
Surge Immunity Test: AC Power Line: line to line 6 kV, line to earth 10 kV
(2)
8 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Safety &EMC Compliance
EMS Standards
Notes
EN 61000-4-6
Conducted Radio Frequency Disturbances Test-CS
EN 61000-4-8
Power Frequency Magnetic Field Test
EN 61000-4-11
Voltage Dips
EN 61547
Electromagnetic Immunity Requirements Applies To Lighting Equipment
Note: (1) This LED driver meets the EMI specifications above, but EMI performance of a luminaire that contains it
depends also on the other devices connected to the driver and on the fixture itself.
(2) To perform electric strength (hi-pot) testing, the “GDT ground disconnect” (nut and metal lock sheet) on the
driver end-cap should be removed temporarily to prevent the internal gas discharge tube from conducting (as
allowed by IEC 60598-1 Clause 10.2). After testing is completed, these items must be reinstalled to restore
line-to-earth surge protection and secure the end cap.
Derating
Lifetime vs. Case Temperature
9 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Inrush Current Waveform
Efficiency vs. Load
EUD-600S140DT(Io=1100mA)
EUD-600S140DT(Io=1400mA)
EUD-600S170DT(Io=1360mA)
EUD-600S170DT(Io=1700mA)
10 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
EUD-600S210DT(Io=1680mA)
EUD-600S210DT(Io=2100mA)
EUD-600S280DT(Io=2240mA)
EUD-600S280DT(Io=2800mA)
EUD-600S420DT(Io=3360mA)
EUD-600S420DT(Io=4200mA)
11 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
EUD-600S560DT(Io=4480mA)
EUD-600S560DT(Io=5600mA)
EUD-600S740DT(Io=5920mA)
EUD-600S740DT(Io=7400mA)
EUD-600S980DT(Io=7840mA)
EUD-600S980DT(Io=9800mA)
12 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
EUD-600S12ADT(Io=10000mA)
EUD-600S12ADT(Io=12500mA)
Power Factor
Total Harmonic Distortion
13 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
Protection Functions
Parameter
External
Thermal
Protection
NTC
Min.
Typ.
Max.
R1
-
7.81 kOhm
-
R2
-
4.16 kOhm
-
10%Ioset
60%Ioset
100%Ioset
10%Ioset>Iomin (default setting is 60%)
Iomin
60%Ioset
100%Ioset
10%Ioset≤Iomin (default setting is 60%)
Protection
Current Floor
Notes
When R_NTC falls below R1, External
Thermal Protection is triggered, reducing
output current until R2 is reached.
When R_NTC is less than R2, output current
is reduced to the programmed “Protection
Current Floor.”
Over Temperature Protection
Decreases output current, returning to normal after over temperature is removed.
Short Circuit Protection
Auto Recovery. No damage will occur when any output is short circuited. The output
shall return to normal when the fault condition is removed.
Over Voltage Protection
Limits output voltage at no load and in case the normal voltage limit fails.
Dimming
0-10V Dimming
The recommended implementation of the dimming control is provided below.
Implementation 1: DC Input
Notes:
1. The dimmer can also be replaced by an active 0-10V voltage source signal or passive components like
resistors and zener.
2. Do NOT connect Dim− to the output V− or V+, otherwise the driver will not work properly.
3. If 0-10V dimming is not used, Dim + should be open.
14 / 18
Specifications are subject to changes without notice.
www.inventronics-co.com
Tel: 86-571-56565800
Fax: 86-571-86601139
sales@inventronics-co.com
EUD-600SxxxDT
600W Programmable IP67 Driver
Rev.E
PWM Dimming
Implementation 2: Positive logic
Implementation 3: Negative logic
Time Dimming
Time dimming control includes 3 kinds of modes, they are Self Adapting-Midnight, Self AdaptingPercentage and Traditional Timer.
Self Adapting-Midnight: Automatically adjusts the dimming curve based on the on-time of past two
days (if difference