Make sure to visit
our Website
http://www.sefram.fr
SEFRAM DAS30 / DAS50 /
DAS60
Sefram
Sefram
Handheld Data Acquisition Solution
Capabilities
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
2 to 6 analogue channels
Universal input
DC, AC+DC RMS voltage measurement
Frequency, counter
Temperature: thermocouple, Pt100/Pt1000*
Power analysis function (up to 400Hz for DAS60)
16 logical channels
14-bit resolution
10" TFT panoramic LCD touch screen
1 Ms/s sampling rate
100 kHz bandwidth
32 GB internal hard disk (64GB for DAS60)
32 Mword memory
Interfaces: 2 x USB, Ethernet
Lithium-ion battery
Autonomy: up to 9,5 hours.
110mm Thermal printer module*
IEC 1010 CAT III 600V
* factory options: - printer module (all models)
- Pt100 / Pt1000 (DAS30 / 50)
DAS30 / 50 / 60
Multifunction recorders
for all your applications
The new DAS30 / 50 / 60 series recorders have been designed
to meet the requirements of all applications in industry (IEC
61010, CAT. III 600V). You can view your measurements (traces,
digital values) and record directly in the internal memory or
into a USB memory stick. Using Sefram software, you can
transfer easily your records on a computer.
Universal input
The new DAS30 / 50 / 60 recorders offer universal input, which
are convenient for all types of signals :
- voltage ranges from 1mV to 1000V DC or 425Vrms
- temperature (thermocouples) and Pt100/Pt1000*
- counter, frequency
- current (with optional shunt)
Easy-to-use
Typical applications
Thanks to the new user interface combined with its large
touch screen LCD, the portable DAS recorders are design for
ease of use for a wide range of data recording applications and
easy transfer of your records.
The new DAS30 / 50 / 60 recorders are general purpose and
multifunction recorders and are suitable for many applications:
- maintenance/failure diagnostic on electrical systems
- voltage, current, temperature recording and monitoring
- power analysis for single-phase and three-phase systems
Selection guide
2 isolated universal channels
4 isolated universal channels
6 isolated universal channels
Memory
2 Pt100/Pt1000 input
110mm thermal printer
DAS30
•
32GB
factory option
factory option
DAS50
•
32GB
factory option
factory option
DAS60
•
64GB
•
factory option
Data Acquisition Solution
Sefram
Sefram
SEFRAM DAS30 / DAS50 / DAS60
Handheld Data Acquisition Solution
Channels setup: one screen with colors to differentiate channels
Oscilloscope mode
Digital display of measurements
XY mode
Trigger: several type of trigger, one channel, on a level, slope,
several channels or combined conditions.
With the thermal printer module, you can set up your print
Factory options
110mm thermal printer module
It’s possible to install on Sefram DAS30 / 50 / 60 recorders a thermal printer module (110 mm width, 10 meters thermal
paper roll).
Pt100/Pt1000 board
This board is included in the DAS60 and is a factory option for DAS30 / 50. It adds 2 channels dedicated to Pt100/Pt1000
platinium resistance measurements, with 2 wires, 3 wires or 4 wires setup. Using a 20 bit analog to digital converter, this
card will provide an excellent accuracy and resolution for temperature measurement.
Data Acquisition Solution
Sefram
Sefram
SEFRAM DAS30 / DAS50 / DAS60
Handheld Data Acquisition Solution
SEFRAM VIEWER
This licence free software is supplied with each recorder. It allows the visualization of the recordings and the data
transfer to other applications. SEFRAM Viewer makes the acquired signal analysis easier.
Capabilities
•
•
•
•
•
•
•
•
Curve printing
Display of values (text)
Cursors and zoom
File concatenation
8 math calculations
Up to 120 characters text notes
Bitmap, Excel®, txt, csv export
Easy setup of curves display
FLEXPRO™: a powerful software for your data analysis.
With Flexpro® :
• More than 100 functions
of statistical and math analysis
• Powerful graphical display
• Measurement report editing
ENERGY / POWER ANALYSIS
A very powerful analysis for single-phase or three-phase networks. Analysis is provided with Fresnel diagram
or oscilloscope mode.
The DAS60 can work with 400Hz networks and has a trigger selection function.
Your instrument shows how to connect the inputs with a schematic and you can setup parameters and measurements on the
same screen.
Example of a three-phase network.
Real time display of signals and harmoics (up to rank 50)
Setup of parameters to measure or calculate.
Data Acquisition Solution
SPECIFICATIONS – UNIVERSAL INPUT
Number of channels :
2 (DAS30), 4 (DAS50), 6 (DAS60)
VOLTAGE
Bandwidth :
DC voltage ranges :
Maximum input voltage :
Max offset :
Accuracy :
TRMS AC+DC ranges :
Bandwidth (- 3 dB) :
Response time :
Crest factor :
100 kHz
1 mV to 1000 V
± 500 VDC or 440 VAC
± 5 ranges (up to ± 500 V)
± 0,1% of range ; ± 10µV / ± 0,1% offset
from 200 mV to 424 V
5 Hz - 500 Hz
100 ms typical (40 ms to 50 Hz)
2,2 and 600 V peak voltage
FREQUENCY
Sensitivity :
Duty cycle :
Frequency range :
Basic accuracy
100 mV rms min.
10% min.
0,1 Hz to 100 kHz
0,02% of full scale
PAPER
PLOT CARACTERISTICS (factory option for all models)
Paper width :
Paper speed :
Paper speed in memory mode :
Resolution & accuracy : Y axis :
X axis :
XY mode :
Storage
Setup backup :
Internal hard disk :
Ranges
-210°C to 1200°C
-250°C to 1370°C
-200°C to 400°C
-50°C to 1760°C
200°C to 1820°C
-250°C to 1000°C
-250°C to 1300°C
0°C to 2320°C
-200°C to 900°C
Display :
Automatic measurements :
Interfaces :
Power supply :
Battery (factory installed) :
Autonomy :
Charging time:
Accuracy Cold junction compensation ±1,25°C
POWER ANALYSIS FUNCTION
Networks :
Display :
Measurements :
Single phase, 2 phases, 3 phases
Fresnel diagram, oscilloscope, data
Mean value, RMS value, peak value,
crest factor, THD and DF for voltages
and currents, active, reactive and apparent
power, power factor (cos ϕ)
calculated up to rank 50,
with display and record
Harmonics :
.
SAMPLING
Resolution :
Sampling rate :
Memory length :
Triggering :
14 bit
1M sample/sec per channel max.
32Mword in segments of up to 128 Blocks
Positive edge, negative edge, on logical input,
delay, Go No Go
-100% to +100%
Pre trigger :
.
BANDWIDTH
Bandwidth ( -3dB)
Range :
Range :
Range :
Internal analogue filters :
Slope :
Programmable digital filters :
Slope :
Input impedance (DC) :
Maximum input voltage :
Between 2 terminals of one channel
Isolation between frame ground
and channel :
> 1 V : 100kHz
> 50mV : 50kHz
5 mV : 20kHz
10 kHz, 1 kHz, 100 Hz, 10 Hz.
20 dB/decade
10 Hz, 1 Hz, 0,1 Hz, 0,01 Hz, 0,001 Hz
40 dB/decade
>25MΩ for range 100 MΩ at 500 VDC
.
LOGIC
INPUT
Channels :
TTL – Max voltage :
Sampling rate :
Sensor supply :
Alarms 2 :
16
24V
The same sampling rate as analogue inputs.
9 to 15 V
A & B 0-5 V output.
PT100 / PT1000* INPUT (factory option for DAS30 / 50)
Number of channels :
2
Current :
1mA for Pt100 and 100µA for Pt1000
Resolution :
20 bits
Temperature range:
-200°C to +850°C
Measurements :
2, 3, 4 wires
Accuracy at 20°C :
±0,2°C
unlimited on the hard disk
32 GB (solid state) for DAS30 / 50
and 64GB for DAS60
GENERAL SPECIFICATIONS
TEMPERATURE
Sensor
Couple J
Couple K
Couple T
Couple S
Couple B
Couple E
Couple N
Couple C
Couple L
110 mm
from 1 mm/min to 25mm/s
10 mm/s max.
8 dots per mm
16 dots per mm
8 dots per mm (both axis)
Dimensions & weight :
Operating temperature range :
Max. RH. :
Storage temperature range :
Warranty :
Safety :
OPTIONNAL
10 inches TFT LCD coloured touch screen
F(t)and XY functions.
Zoom, cursors, dV, dT and zoom between
cursors.
Calculation functions
y=ax+b , y=/x/+b, y=a√x+b+c,
y=ax2+b, y=(log x)+b, yae(x+b)+c
20 automatic measurements ( F, T, Vpp, Tm…)
2 x USB port, Ethernet
100 to 240 VAC, ouput 15 V 5A max.
Lithium ion 10,8 V, 6,5 Ah.
Typically 9h30min after a complete charge
4 hours without screen saver
1 hour (recorder off)
Complete charge in 4 hours.
295 x 210 x 105 mm, 2,5 Kg
0°C to 40°C
80% without condensation.
-20°C to 60°C
2 years
IEC 61010 - CAT III 600V
ACCESSORIES
Accessory clamps
SP 201 - 200 AAC, 10mV/1A, ø 15 mm.
SP 221 - 100 AAC, 100mV/1A, ø 15 mm.
SP 230 - 1200 AAC, 10mV/1A, ø 50 mm.
SP 261 - 1200 AAC+DC, 1mV/1A, ø 50 mm.
SP 270 - 2000 AAC, 1 mV/1A, ø 70 mm.
A 1287 - 3000 AAC, 0.333 mV/A, ø 150 mm / Flex
Shunts
Shunts (with banana plugs)
910007100 Shunt CA 0.01 ohm : 3 A
910007200 Shunt CA 0.1 ohm : 1 A
989007000 Shunt CA 50 ohm : 0.05 A
989006000 Shunt CC 1 ohm : 0.5 A
912008000 Shunt CA 10 ohm : 0.15 A
Shunts (with wires)
207030301 Shunt 0.01 ohm : 30 A max
207030500 Shunt 0.001 ohm : 50 A max
Logical channels.
984405500 16 isolated logical channels interface
902407000 16 channels logic probe.
Rugged carrying case
903001000 Rugged carrying case for DAS30/50
906002000 Rugged carrying case for DAS60
FLEXPRO software
916002100 FlexPro View
916002200 FlexPro Standard
916002300 FlexPro Professional
916002400 FlexPro Developer Suite
Printer module (factory option)
903002000 Thermal printer module for DAS30/50
906003000 Thermal printer module for DAS60
Consumables
837500526 Thermal paper roll (10m)
Pt100/Pt1000 (factory option for DAS30 / 50)
903003000 2 channels Pt100/Pt1000
19" rackmount kit
903004000 Rackmount kit for DAS30/50
906001000 Rackmount kit for DAS60
Supplied with : a carrying case, a set of red and black cable
+ alligator clip + quick banana plug, main adaptor, manual (CD-ROM).
FT SEFRAM DAS30/50/60 A 01 - Specifications can be updated without notice
For assistance and ordering
32, rue Edouard Martel • B.P. 55 • 42009 - St Etienne cedex 2
Tel.+33 (0).4.77.59 36 81
Fax. +33 (0).4.77.57.23.23
Website : www.sefram.fr • e-mail : sales@sefram.fr