Safety Switches
NP GP TP
More than safety.
Safety
More than safety.
Around the world – the Swabian
specialists in motion sequence
control for mechanical and systems engineering.
Emil Euchner, the
company’s founder and
inventor of the multiple
limit switch, circa 1928.
EUCHNER’s history began in 1940 with
the establishment of an engineering
office by Emil Euchner. Since that
time, EUCHNER has been involved in
the design and development of switchgear for controlling a wide variety of
motion sequences in mechanical and
systems engineering. In 1953, Emil
Euchner founded EUCHNER + Co., a
milestone in the company’s history. In
1952, he developed the first multiple
limit switch – to this day a symbol of
the enterprising spirit of this familyowned company.
Automation – Safety – ManMachine
Today, our products range from
electromechanical and electronic
components to complex system solutions. With this wide range of products
we can provide the necessary technologies to offer the right solution for
special requirements – regardless of
whether these relate to reliable and
precise positioning or to components
and systems for safety engineering in
the automation sector.
EUCHNER products are sold through a
world-wide sales network of competent partners. With our closeness to
the customer and the guarantee of
reliable solutions throughout the
globe, we enjoy the confidence of customers all over the world.
Quality, reliability, precision
Quality, reliability and precision are the
hallmarks of our corporate philosophy.
They represent concepts and values
to which we feel totally committed.
At EUCHNER, quality means that all
our employees take personal responsibility for the company as a whole
and, in particular, for their own field of
work. This individual commitment to
perfection results in products which
are ideally tailored to the customers’
needs and the requirements of the
market. After all: our customers and
their needs are the focus of all our
efforts. Through efficient and effective
use of resources, the promotion of
personal initiative and courage in finding unusual solutions to the benefit of
our customers, we ensure a high level
of customer satisfaction. We familiarize ourselves with their needs, requirements and products and we learn
from the experiences of our customers’ own customers.
EUCHNER – More than safety.
Quality – made by EUCHNER
2
Table of contents
Safety switches NP/GP/TP
General Information
4
Safety switches NP.../GP... without guard-locking device
Advantages and features
Sample applications
Series NP... 1, 2 and 3 contact switching elements
Series GP... 2 and 4 contact switching elements
6
6
7
8
10
Safety switches TP... with guard-locking device
Advantages and features
Operating principle
Sample applications
Series TP... 2 contact switching elements
Series TP...K 2 contact switching elements with increased overtravel
Series TP... 4 contact switching elements, without door monitoring contact
Series TP...K 4 contact switching elements, without door monitoring contact
with increased overtravel
Series TP... 4 contact switching elements, with door monitoring contact
Series TP...K 4 contact switching elements, with door monitoring contact
with increased overtravel
Series TP... 3 contact switching elements, with door unlock request contact
12
13
14
15
16
18
20
22
Special versions
Series TP... Switching elements with 4 positively driven NC contacts, with door monitoring contact
Series TP... With additional cable entry through the rear mounting face
Series TP... With emergency release through the rear mounting face, short actuation axis
Series TP... With emergency release through the rear mounting face, long actuation axis
Series TP... With M12 plug connectors
Series TP... With 2 M12 plug connectors
30
30
31
32
33
34
36
Actuators
Latch spring for increased retention force
Lockout bar
Safety screws / Replacement screws
Insertion funnel NP/TP
Lock
Adapter NP-K
Built-in LED
Cable glands
Plug connector with / without connection cable
Standard bolt for safety guards
Bolt with emergency release for escape from the hazardous area
Mounting plates EMP for TP...A Satey Switches
38
41
41
41
42
42
43
43
44
44
46
49
50
Index
51
24
26
28
Accessories
Appendix
Technical Status 01-04/04
3
Safety switches NP/GP/TP
General Information
Safety switches are safety-related machine control components
in accordance with EN 954-1 and BGI 575. They are designed to
safely interrupt the safety circuit or to prevent operation until any
danger to the user has been eliminated.
Since safety switches prevent the operation of a system under
certain conditions (generally for as long as the safety guard
remains open), they are also described as interlocking devices.
Interlocking devices are available with or without a guard-locking
device.
According to EN 1088, electromechanical switches with no guardlocking device must be designed so that they positively switch off
hazardous movement when safety guards are opened. They also
prevent machines from being restarted when the safety guard is
open. EUCHNER safety switches NP, GP are examples of an
interlocking device without a guard-locking device.
In order to ensure that the process is not interrupted by
unintentional opening of the safety guard, safety switches with
electromechanical guard-locking devices are frequently used for
process protection.
A guard-locking device can be used for personal protection, if the
locking magnet is controlled by a standstill monitor and the safety
switch has a fail-safe system for monitoring the solenoid.
With the aid of the interlocking monitoring system, EUCHNER safety
switch TP meets all the necessary conditions for use for personal
protection.
Safety switches NP, GP and TP have been designed so that the
same actuators can be used for both types of switch. For the
design engineer, this offers the advantage of simplicity: If safety
switches with and without a guard-locking device are used, only
the drilling pattern for the switch needs to be modified. The
actuator assembly remains the same. For different applications
where hinged and sliding doors are used, EUCHNER offers straight
or bent actuators. Actuators with rubber bushings facilitate flexible fastening or bedding of the actuator. Where there is a slight
misalignment of the door, the actuator aligns itself to the switch
actuator opening.
When inserted, spring bearing actuators (so-called hinged
actuators) fit almost friction-free. They are suitable for small hinged
doors with a minimum radius of 100 mm.
In this context, the actuator with overtravel is a particularly
interesting example. When the door is closed, this allows a certain
amount of “play”. In the closed state, the door can move slightly
in the direction of the actuator. With protective doors this is
particularly useful if they have a rubber buffer as a stop. An actuator
with overtravel prevents unintentional stopping of the machine
when the door or actuator (in the case of the NP, GP switch)
springs back.
4
In practice, a misalignment of the protective doors may be noticed
when in operation. If preventative action is not taken, the actuator
may be driven against the actuator head and damage it when the
door is being closed.
To protect the actuation head, EUCHNER offers a metal funnel for
safety switches NP, GP and TP (see page 42). The use of this
extra component increases the depth of actuator travel and an
overtravel actuatdor does not relieve the system operator from
the responsibility of maintaining the protective door alignment at
regular intervals.
In order to prevent tampering, actuators must be positively
connected to the protective door. It should not be possible to
break the connection with simple tools. All EUCHNER actuators
are supplied with safety screws.
The safety screws and both the straight and bent actuator, are
made of stainless steel. This material property is particularly
necessary for the food and chemical industries where the safety
switch requirements are higher. With their highly resistant housing
material (PA6, a glass-fiber reinforced thermoplastic) and the high
degree of protection IP 67 for safety switches NP, GP and TP,
they can be used in the toughest environmental conditions.
The actuation head in safety switches NP, GP and TP can easily
be changed to any 90° position for the approach direction.
Removing the 4 actuation head screws, the opening for the
actuation head can be rotated to the required approach direction.
If the actuation head is permanent in order to prevent tampering,
it can be secured to the housing with safety screws (see chapter
on accessories).
If an adapter (see page 43) has been installed between the housing
and the actuation head, safety switches NP can be tripped from
the top by actuators with increased overtravel. The unused actuator
opening can be sealed with the cap supplied.
With modern wiring concepts there is a trend towards plug-in
connections. A switch with plug-connectors can be easily replaced
during servicing work. EUCHNER offers safety switches NP and
TP with 6-pole and 11-pole plug connectors. In addition to the
relevant mating connectors, connectors with fixed cables are also
offered as accessories. Safety switches with M12 plug connector
are available on request.
Safety switches NP/GP/TP
Standard aluminum profiles are often used for safety guards. These
are becoming increasingly prevalent due to the ease of installation,
with a groove profile width of 40 mm and/or 45 mm becoming
standard. EUCHNER safety switches NP, GP and TP have the
40 mm width and can be secured flush to the barrier. Specially
developed adapter plates (see pages 33 and 34) facilitate fast
assembly of safety switches TP with the standard profiles. The
adapter plates can be used for all standard commercially available
profiles.
A further move towards standardization was made with the market
introduction of bolts (see pages 33 and 34). For safety switches
NP, GP and TP, EUCHNER offers bolts which can be fastened to
standard profiles with little effort.
Pre-wired with connectors, safety switches NP, GP and TP can
offer maximum protection. The standard safety switches are BG,
CAS, SAQ, SUVA and UL approved.
Your advantages
! Safety switches with separate actuator for protecting safety guards
! Fully insulated by glass fiber reinforced thermoplastic
! Degree of protection IP 67
! 4 Lateral approach directions can be changed quickly and conveniently
! 1 Approach direction from top
! Rear actuator head opening facilitates removal of dirt
! The same actuators can be used for NP, GP and TP switches
! Actuators and safety screws are made of stainless steel
! Actuators with rubber bushings
! Increased actuator overtravel in all directions of approach
! Different switching elements available
! A number of different connection types are available
! Small switch width (NP : 35 mm, GP/TP : 40 mm),
! suitable for aluminum profile assembly
! Attractive design
! Approved by BG, CSA, SAQ, SUVA, UL
5
Safety switches NP/GP/TP
Safety switches NP... without guard-locking device
-Safety switches in the NP series ... offer important advantages
! Safety switches (without guard-locking device) with separate actuator for protecting safety guards
! Installation in accordance with EN 50047 (NP...AS) or alternatively with 40 mm hole spacing (NP...AB)
! Small switch width (35 mm)
! Ideal for profile assembly
! Option: with the adapter set, an upgrade for increased overtravel from the top is available
! Switching elements with 1, 2 or 3 contact elements
! 10 N Retention force and/or 30 N with latch spring
! Connection using cable entry M20 x 1.5 or 6-pole plug connector
! Slide bolts available
Approach direction can be changed quickly
6
Safety switches NP/GP/TP
Sample applications for safety switches in the NP series ...
7
Safety switches NP/GP/TP
*
Safety switches NP...
! With 1, 2 or 3 contact elements
! Cable entry M20x1.5 or
Plug connector SR6 (relevant plug connectors see page 45)
Dimension drawing NP1-AS
(Fixing to EN 50047)
Insertion depth
Insertion
depth
Actuator
inserted
43
35
3,5
(dependent action contact element)
618
1 positively driven NC contact
628
1 positively driven NC contact + 1 NO
contact
638
2 positively driven NC contacts
648
2 positively driven NC contacts +
1 NO contact
20
26
Actuator
removed
4,3
98
v
with adapter H = 105
* for cable entry M
Switching elements
h
31
*
22
21
+1
22
21
22
30
8
35
22
M20x1,5
+1
16
36
618
Please order actuator separately
(see pages 38 to 40).
21
22
21
22
13
14
13
14
21
11
22
12
21
11
22
12
638
31
21
32
22
31
21
32
22
648
13
14
13
14
628
3,5
8,5
Dimension drawing NP1-AB
(40 mm hole spacing)
Insertion depth
h
Insertion
depth
31
5,5
43
30
25
+1
35
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
A
40
8
The safety switch and actuator must be installed
properly. The actuator must be positively
connected with the mounting surface, e.g. by
using safety screws (see page 41) or by welding,
riveting, pinning. The safety switch must not be
used as an end stop.
Changing the approach direction
10
35
3,5
with adapter H = 105
98
v
Installation notes
50
22
+1
Please order actuator
separately
(see pages 38 to 40).
16
36
25
M20x1,5
3,5
8,5
8
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Glass fiber reinforced thermoplastic
Degree of protection to IEC 60529
IP 67 for M20x1.5 / IP 65 for SR6
Mounting position
optional
Mechanical service life
1 x 106 switching cycles
Ambient temperature
- 20 to +80
Approach speed, max.
20
Weight
approx. 0.11
Switching element
618
628
638
648
Contact elements
1 NC
1 NC
+ 1 NO
2 NC
2 NC
+ 1 NO
Switching principle
Dependent action contact element
Contact material
Silver alloy
Rated impulse withstand voltage Uimp
2.5
Rated insulation voltage Ui
NP1: Ui = 400 / NP2: Ui = 250
Utilization category to IEC 947-5-1
AC-15 Ie 4 A Ue 230 V / DC-13 Ie 4 A Ue 24 V
Switching voltage min. at 10 mA
24
Switching current min. at 24 V
30
Conventional thermal current Ith
4
Short circuit protection (control circuit fuse)
to IEC 60269-1: 4 A gG
Connection method NP1...
Screw terminal, M20x1.5
Connection method NP2...
Plug connector SR6
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5 mm2
Insertion depth (necessary minimum travel + permissible overtravel)
Standard actuator
Overtravel actuator
Approach direction side (h)
28 + 2
28 + 7
29.5 + 7
Approach direction from top (v)
29.5 + 1.5
Only with adapter NP-K
Order No. 074 578 / page 45
°C
m/min
kg
kV
V≅
V
mA
A
mm
mm
Pin assignment NP2...
View of
connection
side
inserted
inserted
Dimension drawing NP2...
Unit
628
1
3
21
22
13
14
638
2
4
1
3
21
22
11
12
2
4
Ordering table
Series /
Connection type /
Installation method
NP1...AS-M
Cable entry
Fitting to
EN 50047
NP1...AB-M
Cable entry
40 mm
hole spacing
NP2...AS
Plug connector SR6
Fitting to
EN 50047
NP2...AB
Plug connector SR6
40 mm
hole spacing
Increased
overtravel
Article
A
(side)
NP1-618AS-M
NP1-628AS-M
NP1-638AS-M
NP1-648AS-M
NP1-618AB-M
NP1-628AB-M
NP1-638AB-M
NP1-648AB-M
1 pos. driven NC
1 pos. driven NC + 1 NO
2 pos. driven NC
2 pos. driven NC + 1 NO
1 pos. driven NC
1 pos. driven NC + 1 NO
2 pos. driven NC
2 pos. driven NC + 1 NO
083 685
083 688
083 691
082 280
083 680
083 686
083 690
082 276
NP2-628AS
1 pos. driven NC + 1 NO
059 447
NP2-638AS
2 pos. driven NC
059 449
628
NP2-628AB
1 pos. driven NC + 1 NO
059 448
638
NP2-638AB
2 pos. driven NC
059 450
Switching
element
618
628
638
648
618
628
638
648
628
638
A
(side)
Contact elements
Order No.
Ordering example: NP1, switching element 638, increased overtravel side A, 40 mm hole spacing (B), cable entry M
NP1-638AB-M
Order No. 083 690
9
Safety switches NP/GP/TP
*
Safety Switches GP...
! With 2 or 4 contact elements
! Cable entry M20x1.5
* Approvals pending
Dimension drawing GP1...
Switching elements
528
1 positively driven NC contact +
1 NO contact
2 positively driven NC contacts
4 positively driven NC contacts
3 positively driven NC contacts +
1 NO contact
2 positively driven NC contacts +
2 NO contacts
h
538
2121
2131
31
3131
43
∅ 4,1
32
Actuator
removed
∅ 5,1
22
125
M20 x 1,5 (3x)
30
31
16
40
7,5
16
42
Please order actuator
separately
(see pages 38 to 40).
Actuator
inserted
3
3,5
35
V
21
22
21
22
13
14
13
14
21
22
21
22
11
12
11
12
41
42
33
21
34
22
11
12
41
42
33
21
34
22
11
12
41
42
33
21
34
22
13
3,5
8,5
14
41
42
33
21
34
22
11
12
41
42
33
21
34
22
11
12
41
42
33
21
34
22
13
14
528
538
2121
2131
3131
Changing the approach direction
Upon removal of the actuating head fixing
screws, the approach direction can be changed to any 90° increment. The standard setting is approach direction A.
Assembly instructions
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as
an end stop.
C
A
B
D
A
In the event of faults, the complete safety
switch must be replaced.
10
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Reinforced thermoplastic
Degree of protection
IP 67
according to IEC 60529
Installation position
Any
Mechanical life
2 x 106 operating cycles
Ambient temperature
- 20 to + 80
Approach speed, max.
20
Insertion/extraction force
8/25
Weight
Approx. 0.16
Switching element
528
538
2121
2131
3131
Contact elements
1 NC + 1 NO 2 NC
4 NC
3 NC + 1 NO 2 NC + 2 NO
Switching principle
Slow-action contact element
Contact material
Silver alloy, gold flashed
Rated impulse withstand voltage Uimp
2.5
Rated insulation voltage Ui
250
Utilization category according to IEC 947-5-1
AC-15 Ie 4 A Ue 230 V / DC-13 Ie 4 A Ue 24 V
Switching voltage, min. at 10 mA
12
Switching current, min. at 24 V
1
Conventional thermal current Ith
4
Short circuit protection (control circuit fuse)
According to IEC 60269-1: 4 A gG
Connection method GP...M
Screw terminal, M20x1.5
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5
Insertion depth
Standard actuators
Overtravel actuators
Unit
°C
m/min
N
kg
kV
V≅
V
mA
A
mm²
(necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
28 + 2
29.5 + 1.5
28 + 7
29.5 + 7
mm
mm
Ordering table
Series /
Connection type
Switching
element
Increased
overtravel
528
GP1...M
cable entry
538
2121
2131
3131
Article
GP1-528A-M
A
(side + top)
GP1-538A-M
GP1-2121A-M
GP1-2131A-M
GP1-3131A-M
Contact
elements
1 positively driven NC contact +
1 NO contact
2 positively driven NC contacts
4 positively driven NC contacts
3 positively driven NC contacts +
1 NO contact
2 positively driven NC contacts +
2 NO contacts
Order No.
089 725
090 250
090 252
090 255
090 258
11
Safety switches NP/GP/TP
Safety switches TP... with guard-locking device
EUCHNER safety switch TP has a built-in solenoid (a guard-locking
device) which is designed to provide process and personal
protection.
According to standard EN 1088, switches with a guard-locking
device must have a mechanical unlocking mechanism. This
mechanism must allow manual unlocking of the guard-locking
device from the machine’s access side with a suitable tool or key.
When the tool or key is removed, the mechanical unlocking
mechanism must return automatically to the starting position or
remain in a safe position. The mechanical unlocking mechanism
for safety switch TP meets these requirements.
When delivered, the mechanical unlocking device is sealed to
prevent tampering.
EUCHNER offers an optional lock as an accessory for the
mechanical unlocking mechanism; this can be retro-fitted to the
safety switch cover. Authorized personnel can unlock the
mechanical unlocking device with a key to interrupt the safety
circuit. When the safety switch is unlocked, the operator can
access the machine.
If the hazardous area behind the safety device can be accessed,
measures must be taken to ensure that anyone who is accidentally
locked in (e.g. if a door closes to), can automatically free
themselves. Safety switches TP have an optional emergency
release to the rear that can be operated by a rotary lever.
EUCHNER also offers appropriate bolts for such applications (for
an exact description see page 49).
For safety switches TP, a choice of three M20x1.5 cable entries
are available to the user. Depending on the switch alignment, a
convenient cable entry can be used.
In the case of variant TP...-C1761 (see page 31), the switch has
an extra cable entry to the rear. This allows the cable to be fed
directly to the switch through a drill hole in the safety guard. A flat
seal between the rear of the housing and the mounting face
protects from the penetration of dirt.
Safety switches TP are also available with plug connectors. If an
M12 plug connector (8-pole) is used , it can be connected directly
to an AS-Interface or Profisafe module.
Safety switches TP... with different contact elements
Switching elements with 4 contact elements
offer important advantages
! 2 contact switching elements
! 1 NC contact + 1 NO contact
! 2 NC contacts
! Versatile connection options
! Only one switch for several applications
! Switching elements with 3 contact elements
(with door unlock request contact)
! 2 NC contacts + 1 NO contact
! 4 contact switching elements
! 2 NC contacts + 2 NO contacts
! 3 NC contacts + 1 NO contact
! 4 NC contacts
! Installation in the conventional EUCHNER housing
! No conversion problems
! Familiar housing dimensions and drilling pattern
! Fewer types
! Savings in storage costs
! Redundant (twin-channel) integration into the safety circuit
through the use of 2 electrically separated positively driven
NC contacts. When wiring several safety switches in series,
redundant integration into the safety circuit is also possible.
! Greater safety for the user
! High control category (according to EN 954-1)
! Approval for BG, CSA, SAQ, SUVA, UL
12
Safety switches NP/GP/TP
-Safety switches in the TP series ... offer important advantages
! Safety switches with separate actuator and guard-locking device for protecting safety guards
! Retention force 1200 N in locked state
! Mechanical auxiliary unlocking mechanism from the front
! Mechanical key unlocking mechanism from the front (optional, retro-fit)
! Emergency release through the rear mounting face available as an option
! User-operated mechanism for emergency escape from hazardous area
! A voltage rectifier is placed before the solenoid coil
! Voltage peaks are avoided when the solenoid is switched
! Large selection of switching elements
! Switch with door unlock request contact available
! An unlock command can be issued locally without a stop button
! 3 cable entries M20 x 1.5 or plug connector (6 or 12-pole)
! Switch with M12 plug connector suitable for direct connection to AS-Interface Safety at Work module
! Slide bolts available
Approach direction can be changed quickly
13
Safety switches NP/GP/TP
Operating principle
The sectional drawings show safety switch TP in the three basic
positions:
! Door closed and locked
! Door closed and unlocked
! Door open and unlocked
Door open and unlocked
When the actuator is being removed, the cam disc is rotated.
Because of its eccentric contour, the plunger is pressed fully down.
NO contact 13-14 closes and sends a signal to the control that
the safety guard is open.
Since the solenoid plunger and the cam disc are positively
connected, the NC contacts 21-22 & 41-42 remain securely open.
This design feature of the guard-locking device ensures that the
locking mechanism (solenoid plunger) cannot lock if the safety
guard is open. This is also mentioned in BGI 575 Protection
Against Unintentional Closing.
Door closed and locked
If the solenoid plunger is in the top position (right illustration), this
prevents rotation of the cam disc in the actuation head. The
actuator or safety guard is therefore locked. When the plunger is
in this position, positively driven NC contacts 21-22 and 41-42
are held in the closed position. This means that the machine
protected by the safety circuit can be started.
Door closed and unlocked
If the solenoid is switched on (in the case of safety switches
TP...4131), the cam disc blocking is lifted and the NC contacts
(21-22 and 41-42) are opened at the same time. NO contact 3334 signals that the interlocking solenoid is unlocked.
The state of a switching element can be polled because of the
sequential switching pattern (solenoid plunger can adopt three
basic positions)
In consequence of this technology, EUCHNER’s safety switch TP
has a slender structural design. It is ideally suited to applications
for which small structural switch designs are essential.
Door
closed
and
locked
Actuator
Door
closed
and
unlocked
Door
open
and
unlocked
42
21
33
22
34
13
14
E1
E2
42
21
33
22
34
13
14
E1
E2
42
21
33
22
34
13
14
E1
E2
Safety circuit
Channel A
Channel B
Door closed
41
41
41
Door locked
+24 V
PLC
Output
14
Inputs
Safety switches NP/GP/TP
Applications for TP... series Safety Switches
15
Safety switches NP/GP/TP
*
Safety switches TP...
! With 2 contact elements
! With door monitoring contact for TP3.../TP4...
! Cable entry M20x1.5 or
Plug connector SR6 (relevant plug connectors see page 45)
Dimension drawing TP...M
h
Insertion depth
43
v
Insertion
depth
35
* with cable entry M, 24 V DC / 110 V AC
Switching elements
31
3,5
*
(dependent action contact element)
528
1 positively driven NC contact + 1 NO
contact
537
1 positively driven NC contact +
1 NC contact as door monitoring
contact
538
2 positively driven NC contacts
Actuator inserted
locked
unlocked
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
144
Mechanical unlocking
mechanism
E1
E2
E2
E1
E2
21
22
21
22
21
22
13
14
13
14
13
14
21
22
21
22
21
22
11
12
11
12
11
12
21
22
21
22
21
22
11
12
11
12
11
12
528
537
22
M20x1,5 (3x)
Mechanical unlocking
screw
E1
Actuator
removed
16
30
Locking methods
16
42
Please order actuator separately
(see pages 38 to 40).
538
40
TP1.../ TP3...: Actuator inserted, mechanically
locked, unlock by applying voltage.
TP2.../ TP4...: Lock by applying voltage.
3,5
8,5
Mechanical unlocking mechanism
Safety switches can be unlocked by using the
mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
Dimension drawing TP...SR6
Please order plug connector
separately
(see page 45).
inserted
inserted
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
A
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
16
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Glass fiber reinforced thermoplastic
Degree of protection to IEC 60529
TP...M: IP 67 / TP...SR6: IP 65
Mounting position
optional
Mechanical service life
1 x 106 switching cycles
Ambient temperature
- 20 to + 55
Approach speed, max.
20
Insertion/extraction force (not locked)
TP1, TP2: approx. 8 / TP3: approx. 10 / TP4: approx. 15
Retention force when locked
1200
Weight
approx. 0.5
Switching element
528
537
538
Contact elements
1 NC
+ 1 NO
1 NC
+ 1 NC
2 NC
Switching principle
Dependent action contact element
Contact material
silver alloy, gold flashed
Rated impulse withstand voltage Uimp
2.5
Rated insulation voltage Ui
250
Utilization category to IEC 947-5-1
AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
Switching voltage min. at 10 mA
12
Switching current min. at 24 V
10
Conventional thermal current Ith
6
Short circuit protection (control circuit fuse)
to IEC 60269-1: 6 A gG
Connection method TP...M
Screw terminal, M20x1.5
Connection method TP...SR6
Plug connector SR6
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5 mm2
Solenoid
Connection
reverse polarity protected, integrated bridge rectifier
Solenoid operating voltage
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
Duty cycle
100
Power consumption
8
Insertion depth (necessary minimum travel + permissible overtravel)
Standard actuator
Overtravel actuator
Approach direction side (h)
28 + 2
28 + 7
Approach direction from top (v)
29.5 + 1.5
–
5
Pin assignment TP...SR6
View of
connection side
5
E1
E2
6
528
5
E1
E2
537
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
E2
6
Unit
538
6
3
21
22
4 Solenoid monitoring
3
21
22
4 Door monitoring
3
21
22
4 Solenoid monitoring
1
13
14
2 Solenoid monitoring
1
11
12
2 Solenoid monitoring
1
11
12
2 Solenoid monitoring
Ordering table
Series /
Locking method /
Connection type
TP1-...M / TP3-...M
Mechanical locking,
Cable entry
TP2-...M / TP4-...M
Electrical locking,
Cable entry
TP1-...SR6 / TP3-...SR6
Mechanical locking,
Plug connector SR6
TP2-...SR6 / TP4-...SR6
Electrical locking,
Plug connector SR6
Switching
element
528
537
538
528
537
538
528
537
538
528
537
538
Increased
overtravel
A
(side)
A
(side)
Article
TP1-528A...M
TP3-537A...M
TP1-538A...M
TP2-528A...M
TP4-537A...M
TP2-538A...M
TP1-528A...SR6
TP3-537A...SR6
TP1-538A...SR6
TP2-528A...SR6
TP4-537A...SR6
TP2-538A...SR6
Order No.
Solenoid operating
024
110
084 295
084 300
084 336
084 337
084 310
084 315
084 325
084 330
084 339
084 340
084 333
084 334
087 431
087 435
087 434
087 437
087 433
087 436
087 441
087 444
087 443
087 447
087 442
087 446
Ordering example: TP2, electr. locking, switching element 528, increased overtravel side A,
solenoid operating voltage 230 V AC, cable entry M
TP2-528 A 230 M
voltage
230
084 304
084 338
084 320
084 332
084 341
084 335
087 438
087 440
087 439
087 448
087 450
087 449
Order No. 084 332
17
Safety switches NP/GP/TP
*
Safety switches TP..K..
! Increased overtravel with approach direction from top
! With 2 contact elements
! With door monitoring contact for TP3.../TP4...
! Cable entry M20x1.5 or
Plug connector SR6 (relevant plug connectors see page 45)
Dimension drawing TP...M
Insertion depth
h
50
v
Insertion
depth
42
* with cable entry M, 24 V DC / 110 V AC
Switching elements
31
3,5
*
(dependent action contact element)
528
1 positively driven NC contact + 1 NO
contact
537
1 positively driven NC contact +
1 NC contact as door monitoring
contact
538
2 positively driven NC contacts
Actuator inserted
locked
unlocked
Actuator
removed
199
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
E1
E1
E2
E2
144
Mechanical unlocking
mechanism
21
22
21
22
21
22
13
14
13
14
13
14
21
22
21
22
21
22
11
12
11
12
11
12
21
22
21
22
21
22
11
12
11
12
11
12
528
537
22
M20x1,5 (3x)
Mechanical unlocking
screw
E1
E2
16
30
538
40
42
Locking methods
16
Please order actuator separately
(see pages 38 to 40).
TP1.../ TP3...: Actuator inserted, mechanically
locked, unlock by applying voltage.
TP2.../ TP4...: Lock by applying voltage.
3,5
8,5
Mechanical unlocking mechanism
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
Dimension drawing TP...SR6
Please order plug connector
separately
(see page 45).
inserted
inserted
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction an be changed to any
90° increment. The standard setting is approach
direction K.
K
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
18
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Glass fiber reinforced thermoplastic
Degree of protection to IEC 60529
TP...M: IP 67 / TP...SR6: IP 65
Mounting position
optional
Mechanical service life
1 x 106 switching cycles
Ambient temperature
- 20 to + 55
Approach speed, max.
20
Insertion/extraction force (not locked)
approx. 8
Retention force when locked
1200
Weight
approx. 0.5
Switching element
528
537
538
Contact elements
1 NC
+ 1 NO
1 NC
+ 1 NC
2 NC
Switching principle
Dependent action contact element
Contact material
silver alloy, gold flashed
Rated impulse withstand voltage Uimp
2.5
Rated insulation voltage Ui
250
Utilization category to IEC 947-5-1
AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
Switching voltage min. at 10 mA
12
Switching current min. at 24 V
10
Conventional thermal current Ith
6
Short circuit protection (control circuit fuse)
to IEC 60269-1: 6 A gG
Connection method TP...M
Screw terminal, M20x1.5
Connection method TP...SR6
Plug connector SR6
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5 mm2
Solenoid
Connection
reverse polarity protected, integrated bridge rectifier
Solenoid operating voltage
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
Duty cycle
100
Power consumption
8
Insertion depth (necessary minimum travel + permissible overtravel)
Standard actuator
Overtravel actuator
Approach direction side (h)
28 + 2
28 + 7
Approach direction from top (v)
29.5 + 1.5
29.5 + 7
5
Pin assignment TP...SR6
View of
connection side
5
E1
E2
6
528
5
E1
E2
538
3
21
22
4 Solenoid monitoring
3
21
22
4
1
13
14
2 Solenoid monitoring
1
11
12
2 Solenoid monitoring
Door monitoring
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
E2
6
537
Unit
6
3
21
22
4 Solenoid monitoring
1
11
12
2 Solenoid monitoring
Ordering table
Series /
Locking method /
Connection type
TP1-...M / TP3-...M
Mechanical locking,
Cable entry
TP2-...M / TP4-...M
Electrical locking,
Cable entry
TP1-...SR6 / TP3-...SR6
Mechanical locking,
Plug connector SR6
TP2-...SR6 / TP4-...SR6
Electrical locking,
Plug connector SR6
Switching
element
528
537
538
528
537
538
528
537
538
528
537
538
Increased
overtravel
K
(side + top)
K
(side + top)
Article
TP1-528K...M
TP3-537K...M
TP1-538K...M
TP2-528K...M
TP4-537K...M
TP2-538K...M
TP1-528K...SR6
TP3-537K...SR6
TP1-538K...SR6
TP2-528K...SR6
TP4-537K...SR6
TP2-538K...SR6
Order No.
Solenoid operating voltage
024
110
230
084 342
084 347
084 343 on request
084 344
on request
084 348
084 349
084 346 on request
088 210
088 213
088 212
on request on request
088 214
088 216
088 215
Ordering example: TP2, electr. locking, switching element 528, increased overtravel side and
top K, solenoid operating voltage 24 V AC/DC, cable entry M
TP2-528 K 024 M
Order No. 084 344
19
Safety switches NP/GP/TP
*
Safety switches TP...
! With 4 contact elements, without door monitoring contact
! Cable entry M20x1.5 or
Plug connector SR11 (relevant plug connectors see page 45)
Dimension drawing TP...M
*
* with cable entry M, 24 V DC / 110 V AC
Switching elements
h
31
Insertion depth
Insertion
depth
(dependent action contact element)
4131 2 positively driven NC contacts +2 NO
contacts
Actuator
removed
3,5
43
35
v
Actuator inserted
locked
unlocked
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
E1
E1
E2
E2
192
41
144
Mechanical unlocking
mechanism
M20x1,5 (3x)
Mechanical unlocking
screw
E1
E2
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
4131
Locking methods
22
TP1...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP2...: Lock by applying voltage.
Mechanical unlocking mechanism
16
40
16
42
Please order actuator separately
(see pages 38 to 40).
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
30
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
3,5
8,5
Dimension drawing TP...SR11
Please order plug connector
separately
(see page 45).
inserted
inserted
A
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
20
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Housing material
Degree of protection to IEC 60529
Mounting position
Mechanical service life
Ambient temperature
Approach speed, max.
Insertion/extraction force (not locked)
Retention force when locked
Weight
Switching element
Contact elements
Switching principle
Contact material
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Utilization category to IEC 947-5-1
Switching voltage min. at 10 mA
Switching current min. at 24 V
Conventional thermal current Ith
Short circuit protection (control circuit fuse)
Connection method TP...M
Connection method TP...SR11
Connection to switching element
Solenoid
Connection
Solenoid operating voltage
Duty cycle
Power consumption
Insertion depth (necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
Value
Glass fiber reinforced thermoplastic
TP...M: IP 67 / TP...SR11: IP 65
optional
1 x 106 switching cycles
- 20 to + 55
20
approx. 8
1200
approx. 0.5
4131
+ 2 NO
2 NC
Dependent action contact element
silver alloy, gold flashed
TP...M: Uimp = 2.5 / TP...SR11: Uimp = 1,5
TP...M: Ui = 250 / TP...SR11: Ui = 50
TP...M: AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
TP...SR11: AC-15 Ie 4 A Ue 50 V / DC-13 Ie 4 A Ue 24 V
12
10
TP...M: 6 / TP...SR11: 4
to IEC 60269-1, TP ...M: 6 A gG / TP...SR11: 4 A gG
Screw terminal, M20x1.5
Plug connector SR11
Screw terminals, max. cross-section of a single connector 1.5 mm2
reverse polarity protected, integrated bridge rectifier
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
100
8
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
–
9
Pin assignment TP...SR11
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
E2
4131
View of
connection side
Unit
7
5
3
1
41
33
21
13
42
34
22
14
10
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Solenoid monitoring
Ordering table
Series /
Locking method /
Connection type
TP1-...M
Mechanical locking,
Cable entry
TP2-...M
Electrical locking,
Cable entry
TP1-...SR11
Mechanical locking,
Plug connector SR11
TP2-...SR11
Electrical locking,
Plug connector SR11
Switching
element
Increased
overtravel
Article
Order No.
Solenoid operating voltage
024
110
230
084 115
084 116 084 117
TP1-4131A...M
4131
A
(side)
–
–
–
084 125
084 126
084 128
–
–
–
–
–
–
–
TP2-4131A...M
088 202
TP1-4131A...SR11
4131
A
(side)
–
088 203
TP2-4131A...SR11
Ordering example: TP2, electr. locking, switching element 4131, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP2-4131 A 024 M
–
Order No. 084 125
21
Safety switches NP/GP/TP
*
Safety switches TP..K..
! Increased overtravel with approach direction from top
! With 4 contact elements, without door monitoring contact
! Cable entry M20x1.5 or
Plug connector SR11 (relevant plug connectors see page 45)
Dimension drawing TP...M
*
* with cable entry M, 24 V DC / 110 V AC
Switching elements
Insertion depth
h
31
Insertion
depth
(dependent action contact element)
4131 2 positively driven NC contacts +2 NO
contacts
Actuator
removed
50
42
3,5
v
Actuator inserted
locked
unlocked
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
E1
E1
E2
E2
199
41
144
Mechanical unlocking
mechanism
22
M20x1,5 (3x)
Mechanical unlocking
screw
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
4131
Locking methods
TP1...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP2...: Lock by applying voltage.
Mechanical unlocking mechanism
16
40
16
Please order actuator separately
(see pages 38 to 40).
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
30
42
Changing the approach direction
3,5
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction K.
8,5
Dimension drawing TP...SR11
Please order plug connector
separately
(see page 45).
inserted
inserted
K
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
22
E1
E2
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Housing material
Degree of protection to IEC 60529
Mounting position
Mechanical service life
Ambient temperature
Approach speed, max.
Insertion/extraction force (not locked)
Retention force when locked
Weight
Switching element
Contact elements
Switching principle
Contact material
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Utilization category to IEC 947-5-1
Switching voltage min. at 10 mA
Switching current min. at 24 V
Conventional thermal current Ith
Short circuit protection (control circuit fuse)
Connection method TP...M
Connection method TP...SR11
Connection to switching element
Solenoid
Connection
Solenoid operating voltage
Duty cycle
Power consumption
Insertion depth (necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
Value
Glass fiber reinforced thermoplastic
TP...M: IP 67 / TP...SR11: IP 65
optional
1 x 106 switching cycles
- 20 to + 55
20
approx. 8
1200
approx. 0.5
4131
+ 2 NO
2 NC
Dependent action contact element
silver alloy, gold flashed
TP...M: Uimp = 2.5 / TP...SR11: Uimp = 1,5
TP...M: Ui = 250 / TP...SR11: Ui = 50
TP...M: AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
TP...SR11: AC-15 Ie 4 A Ue 50 V / DC-13 Ie 4 A Ue 24 V
12
10
TP...M: 6 / TP...SR11: 4
to IEC 60269-1, TP ...M: 6 A gG / TP...SR11: 4 A gG
Screw terminal, M20x1.5
Plug connector SR11
Screw terminals, max. cross-section of a single connector 1.5 mm2
reverse polarity protected, integrated bridge rectifier
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
100
8
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
29.5 + 7
9
Pin assignment TP...SR11
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
E2
4131
View of
connection side
Unit
7
5
3
1
41
33
21
13
42
34
22
14
10
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Solenoid monitoring
Ordering table
Series /
Locking method /
Connection type
TP1-...M
Mechanical locking,
Cable entry
TP2-...M
Electrical locking,
Cable entry
TP1-...SR11
Mechanical locking,
Plug connector SR11
TP2-...SR11
Electrical locking,
Plug connector SR11
Switching
element
Increased
overtravel
Article
TP1-4131K...M
4131
K
(side + top)
TP2-4131K...M
Order No.
Solenoid operating voltage
024
110
230
084 150
084 254 084 255
–
–
–
084 253
on request
on request
–
–
–
–
–
–
–
088 217
TP1-4131K...SR11
4131
K
(side + top)
–
088 218
TP2-4131K...SR11
Ordering example: TP2, electr. locking, switching element 4131, increased overtravel side
and top K, solenoid operating voltage 024 V AC/DC, cable entry M
TP2-4131 K 024 M
–
Order No. 084 253
23
Safety switches NP/GP/TP
*
Safety switches TP...
! With 4 contact elements
! With door monitoring contact
! Cable entry M20x1.5 or
Plug connector SR11 (relevant plug connectors see page 45)
Dimension drawing TP...M
h
Insertion depth
43
v
Insertion
depth
35
* with cable entry M, 24 V DC / 110 V AC
Switching elements
31
3,5
*
(dependent action contact element)
4131 2 positively driven NC contacts +
1 NO contact + 1 NO contact as door
monitoring contact
2131 2 positively driven NC contacts +
1 NO contact + 1 NC contact as door
monitoring contact
4121 2 positively driven NC contacts + 1 NC /
1 NO contact as door monitoring contact
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Actuator inserted
locked
unlocked
Actuator
removed
144
Mechanical unlocking
mechanism
M20x1,5 (3x)
Mechanical unlocking
screw
E1
E1
E2
E2
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
4131
22
41
E1
E2
16
30
40
Please order actuator separately
(see pages 38 to 40).
16
42
2131
4121
Locking methods
3,5
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
8,5
Dimension drawing TP...SR11
Mechanical unlocking mechanism
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
Changing the approach direction
inserted
inserted
Please order plug connector
separately
(see page 45).
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
A
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
24
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Housing material
Degree of protection to IEC 60529
Mounting position
Mechanical service life
Ambient temperature
Approach speed, max.
Insertion/extraction force (not locked)
Retention force when locked
Weight
Switching element
Contact elements
Switching principle
Contact material
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Utilization category to IEC 947-5-1
Switching voltage min. at 10 mA
Switching current min. at 24 V
Conventional thermal current Ith
Short circuit protection (control circuit fuse)
Connection method TP...M
Connection method TP...SR11
Connection to switching element
Solenoid
Connection
Solenoid operating voltage
Duty cycle
Power consumption
Insertion depth (necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
Pin assignment TP...SR11
Value
Glass fiber reinforced thermoplastic
TP...M: IP 67 / TP...SR11: IP 65
optional
1 x 106 switching cycles
- 20 to + 55
20
TP3: approx. 10 / TP4: approx. 15
1200
approx. 0.5
4131
2131
4121
2 NC + 1 NO + 1 NO 2 NC + 1 NO + 1 NC 2 NC + 1 NC + 1 NO
Dependent action contact element
silver alloy, gold flashed
TP...M: Uimp = 2.5 / TP...SR11: Uimp = 1.5
TP...M: Ui = 250 / TP...SR11: Ui = 50
TP...M: AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
TP...SR11: AC-15 Ie 4 A Ue 50 V / DC-13 Ie 4 A Ue 24 V
12
10
TP...M: 6 / TP...SR11: 4
to IEC 60269-1, TP ...M: 6 A gG / TP...SR11: 4 A gG
Screw terminal, M20x1.5
Plug connector SR11
Screw terminals, max. cross-section of a single connector 1.5 mm2
reverse polarity protected, integrated bridge rectifier
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
100
8
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
–
9
E2
View of
connection side
9
E1
4131
7
5
3
1
41
33
21
13
42
34
22
14
E2
10
2131
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Door monitoring
9
E1
7
5
3
1
41
33
21
11
42
34
22
12
kV
V≅
V
mA
A
mm2
mm
mm
E1
4121
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Door monitoring
°C
m/min
N
N
kg
%
W
E2
10
Unit
7
5
3
1
41
31
21
13
42
32
22
14
10
8 Solenoid monitoring
6 Door monitoring
4 Solenoid monitoring
2 Door monitoring
Ordering table
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
TP4-...M
Electrical locking,
Cable entry
TP3-...SR11
Mechanical locking,
Plug connector SR11
TP4-...SR11
Electrical locking,
Plug connector SR11
Switching
element
4131
2131
4121
4131
2131
4121
4131
2131
4121
4131
2131
4121
Increased
overtravel
A
(side)
A
(side)
Article
TP3-4131A...M
TP3-231A...M
TP3-4121A...M
TP4-4131A...M
TP4-2131A...M
TP4-4121A...M
TP3-4131A...SR11
TP3-2131A...SR11
TP3-4121A...SR11
TP4-4131A...SR11
TP4-2131A...SR11
TP4-4121A...SR11
Order No.
Solenoid operating
024
110
084 129
084 130
084 142
084 143
084 135
084 137
084 132
084 133
084 145
084 147
084 139
084 140
088 204
088 205
–
088 206
088 207
088 208
–
088 209
Ordering example: TP4, electr. locking, switching element 4131, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP4-4131 A 024 M
voltage
230
084 131
084 144
084 138
084 134
084 148
084 141
–
–
Order No. 084 132
25
Safety switches NP/GP/TP
*
Safety switches TP..K..
! Increased overtravel with approach direction from top
! With 4 contact elements, with door monitoring contact
! Cable entry M20x1.5 or
Plug connector SR11 (relevant plug connectors see page 45)
Dimension drawing TP...M
Insertion depth
h
50
v
Insertion
depth
42
* with cable entry M, 24 V DC / 110 V AC
Switching elements
31
3,5
*
(dependent action contact element)
4131 2 positively driven NC contacts +
1 NO contact + 1 NO contact as door
monitoring contact
2131 2 positively driven NC contacts +
1 NO contact + 1 NC contact as door
monitoring contact
4121 2 positively driven NC contacts + 1 NC /
1 NO contact as door monitoring contact
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Actuator
removed
199
Actuator inserted
locked
unlocked
144
Mechanical unlocking
mechanism
M20x1,5 (3x)
Mechanical unlocking
screw
E1
E2
E2
22
41
16
30
E1
E2
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
4131
2131
40
16
42
Please order actuator separately
(see pages 38 to 40).
E1
4121
Locking methods
3,5
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
8,5
Dimension drawing TP...SR11
Mechanical unlocking mechanism
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
inserted
inserted
Please order plug connector
separately
(see page 45).
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction K.
K
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
26
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Housing material
Degree of protection to IEC 60529
Mounting position
Mechanical service life
Ambient temperature
Approach speed, max.
Insertion/extraction force (not locked)
Retention force when locked
Weight
Switching element
Contact elements
Switching principle
Contact material
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Utilization category to IEC 947-5-1
Switching voltage min. at 10 mA
Switching current min. at 24 V
Conventional thermal current Ith
Short circuit protection (control circuit fuse)
Connection method TP...M
Connection method TP...SR11
Connection to switching element
Solenoid
Connection
Solenoid operating voltage
Duty cycle
Power consumption
Insertion depth (necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
Pin assignment TP...SR11
Value
Glass fiber reinforced thermoplastic
TP...M: IP 67 / TP...SR11: IP 65
optional
1 x 106 switching cycles
- 20 to + 55
20
TP3: approx. 10 / TP4: approx. 15
1200
approx. 0.5
4131
2131
4121
2 NC + 1 NO + 1 NO 2 NC + 1 NO + 1 NC 2 NC + 1 NC + 1 NO
Dependent action contact element
silver alloy, gold flashed
TP...M: Uimp = 2.5 / TP...SR11: Uimp = 1.5
TP...M: Ui = 250 / TP...SR11: Ui = 50
TP...M: AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
TP...SR11: AC-15 Ie 4 A Ue 50 V / DC-13 Ie 4 A Ue 24 V
12
10
TP...M: 6 / TP...SR11: 4
to IEC 60269-1, TP ...M: 6 A gG / TP...SR11: 4 A gG
Screw terminal, M20x1.5
Plug connector SR11
Screw terminals, max. cross-section of a single connector 1.5 mm2
reverse polarity protected, integrated bridge rectifier
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
100
8
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
29.5 + 7
9
E2
View of
connection side
9
E1
4131
7
5
3
1
41
33
21
13
42
34
22
14
10
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Door monitoring
9
E1
E2
2131
7
5
3
1
41
33
21
11
42
34
22
12
kV
V≅
V
mA
A
mm2
mm
mm
E1
4121
8 Solenoid monitoring
6 Solenoid monitoring
4 Solenoid monitoring
2 Door monitoring
°C
m/min
N
N
kg
%
W
E2
10
Unit
7
5
3
1
41
31
21
13
42
32
22
14
10
8 Solenoid monitoring
6 Door monitoring
4 Solenoid monitoring
2 Door monitoring
Ordering table
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
TP4-...M
Electrical locking,
Cable entry
TP3-...SR11
Mechanical locking,
Plug connector SR11
TP4-...SR11
Electrical locking,
Plug connector SR11
Switching
element
4131
2131
4121
4131
2131
4121
4131
2131
4121
4131
2131
4121
Increased
overtravel
K
(side + top)
K
(side + top)
Article
TP3-4131K...M
TP3-2131K...M
TP3-4121K...M
TP4-4131K...M
TP4-2131K...M
TP4-4121K...M
TP3-4131K...SR11
TP3-2131K...SR11
TP3-4121K...SR11
TP4-4131K...SR11
TP4-2131K...SR11
TP4-4121K...SR11
Order No.
Solenoid operating
024
110
084 256
084 257
084 264
084 260
084 259 on request
084 266
084 263
088 219
088 220
088 221
–
088 222
088 223
088 224
Ordering example: TP4, electr. locking, switching element 4131, increased overtravel side and
top K, solenoid operating voltage 024 V AC/DC, cable entry M
TP4-4131 K 024 M
voltage
230
084 258
084 265
084 262
on request
–
Order No. 084 259
27
Safety switches NP/GP/TP
Safety switches TP...
! With door unlock request contact
! With 3 contact elements
! Cable entry M20x1.5 or
Plug connector SR11 (relevant plug connectors see page 45)
Dimension drawing TP...M
Switching elements
h
31
Insertion depth
3,5
43
35
v
Insertion
depth
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Actuator fully
inserted
Closed
E1
E2
Actuator
removed
Locked
Request
E1
E2
E1
E2
144
Auxiliary actuation
(dependent action contact element)
4120 1 positively driven NC contact as door
unlock request contact
1 positively driven NC contact +
1 NO contact
(no door monitoring contact)
M20x1,5 (3x)
Locking screw
31
21
13
32
22
14
31
21
13
32
22
14
31
21
13
32
22
14
4120
Locking methods
22
TP5...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP6...: Lock by applying voltage.
16
30
40
42
Door unlock request contact
The unlock request contact 21-22 is operated if
the door together with the actuator is moved
slightly away from its closed position. This action opens the 21-22 contact, which can then
be used via the PLC to unlock the solenoid. The
door can then be opened in the normal way. This
procedure ensures that the control concepts
such as run down and safe speed monitoring
can still be adhered to.
16
Please order actuator separately
(see pages 38 to 40).
3,5
8,5
Dimension drawing TP...SR11
Please order plug connector
separately
(see page 45).
Auxiliary actuation
Changing the approach direction
inserted
inserted
Used to manually operate the switch element.
The 21-22 positively driven contact can be
opened but the safety guard remains locked.
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
A
Installation notes
The safety switch and actuator must be installed properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
28
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameter
Housing material
Degree of protection to IEC 60529
Mounting position
Mechanical service life
Ambient temperature
Approach speed, max.
Insertion/extraction force (not locked)
Retention force when locked
Weight
Switching element
Contact elements
Switching principle
Contact material
Rated impulse withstand voltage Uimp
Rated insulation voltage Ui
Utilization category to IEC 947-5-1
Switching voltage min. at 10 mA
Switching current min. at 24 V
Conventional thermal current Ith
Short circuit protection (control circuit fuse)
Connection method TP...M
Connection method TP...SR11
Connection to switching element
Solenoid
Connection
Solenoid operating voltage
Duty cycle
Power consumption
Insertion depth (necessary minimum travel + permissible overtravel)
Approach direction side (h)
Approach direction from top (v)
Value
Glass fiber reinforced thermoplastic
TP...M: IP 67 / TP...SR11: IP 65
optional
5 x 105 switching cycles
- 20 to + 55
20
approx. 8
800
approx. 0.5
4120
1 NC
+ 1 NC
+ 1 NO
Dependent action contact element
silver alloy, gold flashed
TP...M: Uimp = 2.5 / TP...SR11: Uimp = 1.5
TP...M: Ui = 250 / TP...SR11: Ui = 50
TP...M: AC-15 Ie 6 A Ue 230 V / DC-13 Ie 6 A Ue 24 V
TP...SR11: AC-15 Ie 4 A Ue 50 V / DC-13 Ie 4 A Ue 24 V
12
10
TP...M: 6 / TP...SR11: 4
to IEC 60269-1, TP ...M: 6 A gG / TP...SR11: 4 A gG
Screw terminal, M20x1.5
Plug connector SR11
Screw terminals, max. cross-section of a single connector 1.5 mm2
reverse polarity protected, integrated bridge rectifier
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
100
8
Standard actuator
Overtravel actuator
28 + 2
28 + 7
29.5 + 1.5
–
9
Pin assignment TP...SR11
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
E2
View of
connection side
Unit
4120
5
3
1
31
21
13
32
22
14
10
6 Solenoid monitoring
4 Door unlock request contact
2 Solenoid monitoring
Ordering table
Series /
Locking method /
Connection type
TP5-...M
Mechanical locking,
Cable entry
TP6-...M
Electrical locking,
Cable entry
TP5-...SR11
Mechanical locking,
Plug connector SR11
TP6-...SR11
Electrical locking,
Plug connector SR11
Switching
element
Increased
overtravel
TP5-4120A...M
4120
Order No.
Solenoid operating voltage
024
110
230
Article
084 279
A
(side)
TP6-4120A...M
on request
on request
on request
on request
084 280
TP5-4120A...SR11
4120
A
(side)
on request
TP6-4120A...SR11
Ordering example: TP6, electr. locking, switching element 4120, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP6-4120 A 024 M
Order No. 084 280
29
Safety switches NP/GP/TP
*
Safety switches TP...
! With 4 positively driven NC contacts
! With door monitoring contact
! Cable entry M20x1.5
*
Dimension drawing TP...M
Technical data
As for standard version (see pages 16 - 28).
Insertion depth
h
31
Insertion
depth
Switching elements
v
(dependent action contact element)
4141 2 positively driven NC contacts (solenoid monitoring), 2 positively driven
NC contacts (door monitoring)
43
35
3,5
Approvals pending
Actuator inserted
locked
unlocked
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Actuator
removed
144
192
Mechanical unlocking
mechanism
E1
E1
E2
E2
M20x1,5 (3x)
Mechanical unlocking
screw
41
E1
E2
42
41
42
41
42
31
32
31
32
31
32
21
22
12
21
22
21
22
11
12
11
12
4141
22
11
16
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
40
16
42
Please order actuator separately
(see pages 38 to 40).
Locking methods
30
Mechanical unlocking mechanism
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
3,5
8,5
9
Pin assignment TP...SR11
E1
E2
4141
View of
connection side
7
5
3
1
41
31
21
11
42
32
22
12
10
8 Solenoid monitoring
6 Door monitoring
4 Solenoid monitoring
2 Door monitoring
Ordering table
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
TP4-...M
Electrical locking,
Cable entry
TP3-...SR11
Mechanical locking,
Plug connector SR11
TP4-...SR11
Electrical locking,
Plug connector SR11
30
Switching
element
4141
Increased
overtravel
Article
Order No.
Solenoid operating voltage
024
TP3-4141A024M
084 270
TP4-4141A024M
084 275
TP3-4141A024SR11
088 922
TP4-4141A024SR11
088 923
A
(seitlich)
Safety switches NP/GP/TP
Safety switches TP...
! With additional cable entry through the rear mounting face
! With 4 contact elements, with door monitoring contact
! Cable entry M20x1.5
Dimension drawing TP...M C1761
Technical data
As for standard version (see pages 16 - 28).
Insertion depth
h
31
Deviation from standard
Insertion
depth
3,5
35
43
v
! Opening in the rear of housing for a cable
gland. A flat seal between the rear housing
and the mounting face prevents the ingress
of dirt.
Switching elements
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Mechanical unlocking
screw
22
18
M20x1,5 (3x)
144
Auxiliary
unlocking mechanism
(dependent action contact element)
4131 2 positively driven NC contacts + 1
NO contact + 1 NO contact as door
monitoring contact
2131 2 positively driven NC contacts + 1
NO contact + 1 NC contact as door
monitoring contact
4121 2 positively driven NC contacts +1 NC
contact /
1 NO contact as door monitoring
contact
Actuator inserted
locked
unlocked
∅12
16
Actuator
removed
30
40
42
Flat seal
E1
E2
E2
E1
E2
16
E1
42
41
42
41
42
33
34
33
34
33
34
21
41
22
21
22
21
22
13
14
13
14
13
14
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
4131
3,5
8,5
Please order actuator separately
(see pages 38 to 40).
2131
4121
Locking methods
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
Ordering table (further types available on request)
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
Switching
element
Increased
overtravel
Article
Order No.
Solenoid operating voltage
024
2131
A
(side)
TP3-2131A024M C1761
084 290
Ordering example: TP3, Mech. locking, switching element 2131, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP3-2131 A 024 M C1761
Order No. 084 290
31
Safety switches NP/GP/TP
*
Safety switches TP...
! Emergency release through the rear mounting face
! Short actuation axis
! With 4 contact elements, with door monitoring contact
! Cable entry M20x1.5
*
Dimension drawing TP...M C1743
Approval with switching element 4141 pending
Technical data
As for standard version (see pages 16 - 28).
Insertion depth
h
31
Deviation from standard
Insertion
depth
! Emergency release through the rear
mounting face with marked ON/OFF position
67,5
3,5
35
43
v
Switching elements
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
Emergency
release
Norm.
position
Mechanical unlocking
mechanism
4
Mechanical unlocking
screw
∅14
M4
144
192
36
20
Released
31
(dependent action contact element)
4131 2 positively driven NC contacts +
1 NO contact + 1 NO contact as door
monitoring contact
2131 2 positively driven NC contacts +
1 NO contact + 1 NC contact as door
monitoring contact
4121 2 positively driven NC contacts +1 NC
contact / 1 NO contact as door
monitoring contact
4141 2 positively driven NC contacts (solenoid monitoring), 2 positively driven
NC contacts (door monitoring)
22
Actuator inserted
locked
unlocked
16
30
40
M20x1,5 (3x)
E1
E1
E2
E2
16
42
Actuator
removed
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
3,5
8,5
Please order actuator separately
(see pages 38 to 40).
E1
E2
42
41
42
41
42
31
32
31
32
31
32
21
22
12
21
22
21
22
11
12
11
12
41
11
4131
2131
4121
4141
Locking methods
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
Ordering table (further types available on request)
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
Switching
element
Increased
overtravel
Article
2131
4121
4141
A
(side)
TP3-2131A024M C1743
TP3-4121A024M C1743
TP3-4141A024M C1743
Ordering example: TP3, Mech. locking, switching element 2131, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP3-2131 A 024 M C1743
32
Order No.
Solenoid operating voltage
024
084 285
087 427
086 165
Cat no. 084 285
Safety switches NP/GP/TP
Safety switches TP...
! Emergency release through the rear mounting face
! Long actuation axis
! With 4 contact elements, with door monitoring contact
! Cable entry M20 x 1.5
Dimension drawing TP...M C1993
Technical data
As for standard version (see pages 16 - 28).
Insertion
depth
h
31
Insertion
depth
v
3,5
35
43
for M5 > 35 mm
ISO 1207
(DIN 84)
ISO 4762
(DIN 912)
67,5
61,5
Emergency
release
Norm.
position
Auxiliary
unlocking
mechanism
4
74,7
Locking
screw
∅14
M4
144
192
36
53
Deviation from standard
! The switch with a long actuation axis is
suitable for fixing directly to 40 mm wide
aluminum profiles.
It can be used in combination with bolt TP-.F
(see page 49).
Released
Switching elements
(dependent action contact element)
4131 2 positively driven NC contacts +
1 NO contact + 1 NO contact as door
monitoring contact
2131 2 positively driven NC contacts +
1 NO contact + 1 NC contact as door
monitoring contact
4121 2 positively driven NC contacts +1 NC
contact / 1 NO contact as door
monitoring contact
22
Actuator inserted
locked
unlocked
16
30
40
M20x1,5 (3x)
E1
E1
E2
E2
E1
E2
16
42
Actuator
removed
41
3,5
8,5
Please order actuator separately
(see pages 38 to 40).
42
41
42
41
42
33
34
33
34
33
34
21
22
21
22
21
22
13
14
13
14
13
14
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
33
21
11
42
34
22
12
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
41
31
21
13
42
32
22
14
4131
2131
4121
Locking methods
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
Ordering table (further types available on request)
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
Cable entry
Switching
element
Increased
overtravel
Article
Order No.
Solenoid operating voltage
024
2131
A
(side)
TP3-2131A024M C1993
087 400
Ordering example: TP3, Mech. locking, switching element 2131, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, cable entry M
TP3-2131 A 024 M C1993
Cat no. 087 400
33
Safety switches NP/GP/TP
*
Safety switches TP...
! With 3 positively driven NC contacts
(fed out through M12 plug connector)
! With door monitoring contact
! M12 plug connector (relevant plug connectors see page 44)
Dimension drawing TP...M C1992
31
Insertion
depth
* Approval pending
Deviation from standard
Insertion depth
h
! An M12 8-pole plug connector is used for
connection to safety switch TP...C1992. This
switch version is suitable for direct connection to a safe bus module.
43
3,5
35
v
Switching elements
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
(dependent action contact element)
4141H 2 positively driven NC contacts (solenoid monitoring), 2 positively driven
NC contacts (door monitoring)
Actuator inserted
locked
unlocked
M20x1,5 (2x)
144
Mechanical unlocking
mechanism
Mechanical unlocking
screw
E1
E1
E2
E2
14
22
41
Actuator
removed
E1
E2
42
41
42
41
42
31
32
31
32
31
32
21
22
12
21
22
21
22
11
12
11
12
11
4141H
30
16
42
Locking methods
40
16
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
Mechanical unlocking mechanism
Please order actuator separately
(see pages 38 to 40).
3,5
8,5
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
Installation notes
The safety switch and actuator must be assembled properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
A
The complete safety switch must be replaced in the event of faults.
34
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Glass fiber reinforced thermoplastic
Degree of protection to IEC 60529
IP 67
Mounting position
optional
Mechanical service life
1 x 106 switching cycles
Ambient temperature
- 20 to + 55
Approach speed, max.
20
Insertion/extraction force (not locked)
TP3: approx.10 / TP4: approx. 15
Retention force when locked
1200
Weight
approx. 0.5
Switching element
4141H
Contact elements
+ 2 NC
2 NC
Switching principle
Dependent action contact element
Contact material
silver alloy, gold flashed
Rated impulse withstand voltage Uimp
1,5
Rated insulation voltage Ui
30
Utilization category to IEC 947-5-1
AC-15 Ie 1 A Ue 24 V / DC-13 Ie 1 A Ue 24 V
Switching voltage min. at 10 mA
12
Switching current min. at 24 V
1
Conventional thermal current Ith
1
Short circuit protection (control circuit fuse)
to IEC 60269-1: 1 A gG
Connection method
M12 plug connector
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5 mm2
Solenoid
Connection
reverse polarity protected, integrated bridge rectifier
Solenoid operating voltage
24 V AC/DC (all -15% / +10%)
Duty cycle
100
Power consumption
8
Insertion depth (necessary minimum travel + permissible overtravel)
Standard actuator
Overtravel actuator
Approach direction side (h)
28 + 2
28 + 7
Approach direction from top (v)
29.5 + 1.5
–
Pin assignment TP...C1992
View of
connection side
5
5
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
8
6
4
7
3
1
Unit
E2
4141H
7
2
3
1
41
31
21
11
42
32
22
12
6
8 Solenoid monitoring
4 Solenoid monitoring
2 Door monitoring
Ordering table (further types available on request)
Series /
Locking method /
Connection type
TP3-...M
Mechanical locking,
M12 plug connector
TP4-...M
Electrical locking,
M12 plug connector
Switching
element
Increased
overtravel
4141H
A
(side)
Article
Order No.
Solenoid operating voltage
024
TP3-4141HA024SM8 C1992
087 377
TP4-4141HA024SM8 C1992
087 378
Ordering example: TP3, Mech. locking, switching element 4141H, increased overtravel side A,
solenoid operating voltage 024 V AC/DC, M12 plug connector
TP3-4141H A 024 SM8 C1992
Order No. 087 377
35
Safety switches NP/GP/TP
Safety switches TP...
! With 2 positively driven NC contacts
(fed out through C2 plug connector)
! With door monitoring contact
! 2 M12 plug connectors (4-pole)
Dimension drawing TP...M C2013
Deviation from standard
(M12 plug connector right)
! Two M12 4-pole plug connectors are used for
connection to safety switches TP...C2012 and
TP...C2013. This switch version is suitable for
direct connection to a safe bus module for
example.
Insertion depth
h
31
3,5
Insertion
depth
v
Switching elements
35
43
(dependent action contact element)
4141H 2 positively driven NC contacts (solenoid monitoring), 2 positively driven
NC contacts (door monitoring)
Actuator inserted
locked
unlocked
192
for M5 > 35 mm
ISO 1207 (DIN 84)
ISO 4762 (DIN 912)
144
Mechanical unlocking
mechanism
Actuator
removed
22
M20x1,5
Mechanical
unlocking screw
E1
E1
E2
E2
E1
E2
41
42
41
42
41
42
31
32
31
32
31
32
21
22
12
21
22
21
22
11
12
11
12
4141H
18
11
30
40
Plug
connector
C1
Locking methods
16
42
3,5
Please order
actuator separately
(see pages 38 to 40).
TP3...: Actuator inserted, mechanically locked,
unlock by applying voltage.
TP4...: Lock by applying voltage.
Mechanical unlocking mechanism
16
Plug
connector
C2
8,5
Safety switches can be unlocked by means of
the mechanical unlocking mechanism in the event
of power failure, for example. The mechanical
unlocking mechanism has to be sealed to prevent
tampering (for example with sealing lacquer).
Changing the approach direction
Upon removal of the actuator head fixing screws,
the approach direction can be changed to any
90° increment. The standard setting is approach
direction A.
Plug connector alignment
Plug connector C2 is aligned so that the cable exits downwards in the case of an
angled M12 plug connector.
Plug connector C1 is not aligned.
A
Installation notes
The safety switch and actuator must be assembled properly. The actuator must be
positively connected with the mounting surface, e.g. by using safety screws (see
page 41) or by welding, riveting, pinning. The safety switch must not be used as an
end stop.
36
The complete safety switch must be replaced in the event of faults.
Safety switches NP/GP/TP
Technical data
Parameters
Value
Housing material
Glass fiber reinforced thermoplastic
Degree of protection to IEC 60529
IP 67
Mounting position
optional
Mechanical service life
1 x 106 switching cycles
Ambient temperature
- 20 to + 55
Approach speed, max.
20
Insertion/extraction force (not locked)
approx. 10
Retention force when locked
1200
Weight
approx. 0.5
Switching element
4141H
Contact elements
+ 2 NC
2 NC
Switching principle
Dependent action contact element
Contact material
silver alloy, gold flashed
Rated impulse withstand voltage Uimp
2.5
Rated insulation voltage Ui
250
Utilization category to IEC 947-5-1
AC-15 Ie 1.5 A Ue 230 V / DC-13 Ie 1.5 A Ue 24 V
Switching voltage min. at 10 mA
12
Switching current min. at 24 V
1
Conventional thermal current Ith
2
Short circuit protection (control circuit fuse)
to IEC 60269-1: 2 A gG
Connection method
2 M12 plug connectors
Connection to switching element
Screw terminals, max. cross-section of a single connector 1.5 mm2
Solenoid
Connection
reverse polarity protected, integrated bridge rectifier
Solenoid operating voltage
24 V AC/DC, 110 V AC, 230 V AC (all -15% / +10%)
Duty cycle
100
Power consumption
8
Insertion depth (necessary minimum travel + permissible overtravel)
Standard actuator
Overtravel actuator
Approach direction side (h)
28 + 2
28 + 7
Approach direction from top (v)
29.5 + 1.5
–
Pin assignment TP...C2012 / TP...C2013
4
C1.4
E2
4141H
1
2
C2.3
C2.1
°C
m/min
N
N
kg
kV
V≅
V
mA
A
mm2
%
W
mm
mm
E1
3
View of
connection side of
plug connector
C1 and C2
Unit
41
31
21
11
42
32
22
12
C1.3
C2.4 Solenoid monitoring
C2.2 Door monitoring
Ordering table (further types available on request)
Series /
Locking method /
Connection type
TP3-...C2012
Mechanical locking,
M12 plug connector left
TP4-...C2012
Electrical locking,
M12 plug connector left
TP3-...C2013
Mechanical locking,
M12 plug connector right
Switching
element
4141H
Increased
overtravel
A
(seitlich)
Article
Order No.
Solenoid operating voltage
024
TP3-4141HA024SM4C2012
087 425
TP4-4141HA024SM4C2012
092 772
TP3-4141HA024SM4C2013
087 426
Ordering example: TP3, Mech. locking, switching element 4141H, increased overtravel side A,
solenoid operating voltage 024 V DC, left M12 plug connector
TP3-4141H A 024 SM4 C2012
Order No. 087 425
37
Safety switches NP/GP/TP
Accessories
Standard actuators
Bent actuator
(incl. 2 safety screws M5x10)
Straight actuator
(incl. 2 safety screws M5x10)
Article
Actuator-P-G
Order No.
059 226
Article
Actuator-P-W
Order No.
059 227
Min. door radius 1000 mm
Min. door radius 1000 mm
Hinged actuator for top and bottom hinged doors
(incl. 2 safety screws M5x25)
Article
Hinged actuator P-OU
Adjustment
screw
Order No.
070 050
Adjustment
screw
Min. door radius 90 mm
Hinged actuator for right and left hinged doors
(incl. 2 safety screws M5x10)
Adjustment
screw
Min. door radius 100 mm
38
Article
Hinged actuator P-LR
Adjustment
screw
Order No.
059 440
Safety switches NP/GP/TP
Overtravel actuators
Bent actuator
(incl. 2 safety screws M5x10)
Straight actuator
(incl. 2 safety screws M5x10)
Article
Actuator-P-GN
Order No.
074 570
Article
Actuator-P-WN
Order No.
074 571
Min. door radius 1000 mm
Min. door radius 1000 mm
Hinged actuator for top and bottom hinged doors
(incl. 2 safety screws M5x25)
Article
Hinged actuator P-OUN
Adjustment
screw
Order No.
074 572
Adjustment
screw
Min. door radius 90 mm
Hinged actuator for right and left hinged doors
(incl. 2 safety screws M5x10)
Adjustment
screw
Article
Hinged actuator P-LRN
Order No.
074 573
Adjustment
screw
Min. door radius 100 mm
39
Safety switches NP/GP/TP
Standard actuators with rubber bush
Bent actuator
(incl. 2 safety screws M4x14)
Straight actuator
(incl. 2 safety screws M4x14)
Article
Actuator-P-GT
Order No.
070 046
Article
Actuator-P-WT
Min. door radius 1000 mm
Order No.
070 038
Min. door radius 1000 mm
Overtravel actuators with rubber bush
Bent actuator
(incl. 2 safety screws M4x14)
Straight actuator
(incl. 2 safety screws M4x14)
Article
Actuator-P-GNT
Min. door radius 1000 mm
40
Order No.
074 576
Article
Actuator-P-WNT
Order No.
074 577
Min. door radius 1000 mm
Safety switches NP/GP/TP
Latch spring for increased retention force
Lockout bar
(for safety switches NP/GP or TP in unlocked condition)
Article
Latch spring NP/TP
Order No.
076 501
Article
Lockout bar P
Order No.
070 651
1
7,5
0,5
66
30,5
20
14
ø4,1
Notes
! The latch spring provides an increased retention force of
approx. 30 N
! May only be used in conjunction with the straight actuator
with rubber bush (Order No. 070 046)
When the safety guard is in the open condition, the lockout bar
can be inserted into the safety switch head in-place of the actuator.
The lockout bar can be secured with 2 standard commercially
available padlocks providing a secure lockout method of a
potentially hazardous area. This guarantees protection for anyone
who needs to enter potentially hazardous areas.
(31)
3,5
(20)
min.ø10
8
ca. 4,5
Spring stroke
Installation example
M4 / ø4,1 max.
min.ø10
Safety screws
Screw type
M5x10
Material stainless steel
M5x25
M4x14
Material stainless steel
3x30
self-tapping screw (plastite)
Use
! for straight actuator
! for bent actuator
! for hinged actuators for right
and left hinged doors
! for hinged actuators for top
and bottom hinged doors
! for straight actuator/
bent with bush
! for actuation heads
NP...A, GP... and TP...A
Packaging unit
Article
Order No.
100 pieces
M5x10/V100
086 231
100 pieces
M5x25/V100
073 457
100 pieces
M4x14/V100
086 232
100 pieces
3x30/V100
075 532
Packaging unit
Article
Order No.
100 pieces
3x30/V100
082 237
100 pieces
3x38/V100
076 755
Replacement screws (not safety screws)
Screw type
3x30
self-tapping screw (plastite)
Material stainless steel
3x38
self-tapping screw (plastite)
Use
! for actuation heads
NP...A, GP... and TP...A
! for actuation heads
NP...K, TP...K
41
Safety switches NP/GP/TP
Insertion funnel NP/GP/TP
(for safety switches NP/GP/TP)
+3
47
4
Notes
! May only be used in conjunction with safety
switches NP...A, GP... and TP...A (switches
without top entry overtravel)
! The insertion funnel can only be used in
combination with an overtravel actuator.
! It may only be secured to the actuation head
with the 3 x 34 self-tapping screws (plastite,
supplied)
16
3,5
35
33,5
+1,5
3
32
The insertion funnel provides the actuator with a
wider entry area into the safety switch. With the
insertion funnel the switch head is better
protected against damage.
M3x34 self-tapping screws (plastite, supplied)
are used to secure it to the actuation head.
3,5
8,5
00
10
R>
Article
Insertion funnel NP/GP/TP
000
R>1
00
10
R>
Order No.
086 237
Warning
Lock (mechanical key unlocking mechanism)
The two locks listed as Order No. 084 177 and
086 236 are only suitable for safety switches
TP with metric thread as listed in this catalogue.
43
Application
Blad
67,5
19
Mechanical
unlocking
mechanism
(norm. position)
144
20,5
39
192
locked
Marking
Locking
screw
unlocked
The lock is used in combination with TP safety
switch .
The keyed unlocking mechanism provides
authorized personnel with ability to disengage
the solenoid with a specific key.
The unlocking mechanism holds the solenoid in
the unlocked position.
Installation
Two screws are used to fix the lock to the cover
of the TP safety switch (onto the mechanical
unlocking mechanism).
Notes
42
30
! Please order TP safety switch separately
! 2 keys are included
! All TP safety switches can be retrofitted with
the key release
40
Description
Unique
lock TP
(unique key needed to open)
Identical
lock TP
(standard key opens all locks)
Replacement standard keys (2x)
for identical locks
42
Order No.
084 177
086 236
077 206
Safety switches NP/GP/TP
Adapter NP-K for safety switch NP
Application
Dimension drawing
Adapter NP-K is used for top entry overtravel applications for the
safety switch NP.. only.
Adapter NP-K
Notes
! The adapter cannot be used for GP/TP series of safety
switches
! 4 screws 3 x 38 (not safety screws) are supplied
Ordering table
Article
Adapter NP-K
Order No.
074 578
Assembly
K
A
Built-in LED
Dimension drawing
∅ 28,7
8
1,
R1
The built-in LED is suitable for direct installation in one M20x1.5
thread of the three cable entries in safety switch GP.../TP...
The built-in LED can indicate to the user whether the solenoid is
locked/unlocked or whether the door is open/closed.
The switching element can be wired individually.
Technical data
1
M20x1,5
ca. 115
8
14,5
9,5
38,5
∅ 26,5
Application
27
SW
Parameters
LED color
Connection
Screw-in thread
Operating voltage/
Degree of protection
Value
red
2 connection cables
M20x1 .5
DC 24 V / 45 mA
IP 65
Ordering table
Article
Built-in LED
Order No.
087 423
43
Safety switches NP/GP/TP
Cable glands (plastic)
The cable gland table below shows the cable diameter and the dimensions used with the EUCHNER NP...M, GM..M and TP...M safety
switches.
M
Outer cable diameter D
A
B
E
SW
Article
Order No.
M20 X 1.5
6-12
max. 28
11
27
24
EKPM20/06
086 233
Data in mm
B
E
M
A
SW
M12 plug connector (8-pole socket) with connection cable For TP...C1992 safety switches
8
5
"l"
4
6
3
7
2
1
View of connection side
of 8-pole socket plug
Technical data
Parameters
Plug connector
Connection cable
44
∅6
Wire
color
WH
BN
GN
YE
GY
PK
BU
RD
∅ 14
Socket
pin
1
2
3
4
5
6
7
8
Ordering table
Value
Straight 8-pole
M12 socket plug
Screw connection
Connecting knurled nut
connected to cable screen
8 x 0.25 mm² screened
Outer sheath PVC
Cable length “l”
5m
10 m
15 m
20 m
25 m
50 m
Order No.
077 751
077 752
077 753
077 871
077 872
077 873
Safety switches NP/GP/TP
Plug connector SR6 (socket 6+PE) with / without connection cable
SR6EF...
Socket
pin
1
2
3
4
5
6
쵰
Wire
number
1
2
3
4
5
6
7
SR6WF...
inserted
inserted
View of connection side
of 7-pole socket plug
Technical data
Ordering table
Parameters
Housing material
Number of poles
Nominal voltage
Degree of protection to IEC 60,529
Connection cable
Outer diameter
Wire cross-section
Value
plastic
6 + PE
250 V≅
IP65 /inserted)
PUR grey
∅ 8 mm
1.0 mm²
Plug
version
Socket
straight
Socket
right angle
Connection
cable
None
5m
10 m
15 m
None
5m
10 m
15 m
Article
designation
SR6EF
SR6EF-5000
SR6EF-10000
SR6EF-15000
SR6WF
SR6WF-5000
SR6WF-10000
SR6WF-15000
Order No.
013 176
077 632
077 633
077 634
024 999
077 638
077 639
077 640
Plug connector SR11 (socket 11+PE) with / without connection cable
Socket
pin
1
2
3
4
5
6
7
8
9
10
11
쵰
Wire
number
1
2
3
4
5
6
7
8
9
10
11
12
SR11EF...
SR11WF...
inserted
inserted
View of connection side
of 12-pole socket plug
Ordering table
Technical data
Parameters
Housing material
Number of poles
Nominal voltage
Degree of protection to IEC 60,529
Connection cable
Outer diameter
Wire cross-section
Value
plastic
11 + PE
50 V≅
IP65 /inserted)
PUR grey
∅ 10.5 mm
1.0 mm²
Plug
version
Socket
straight
Socket
right angle
Connection
cable
None
5m
10 m
15 m
None
5m
10 m
15 m
Article
designation
SR11EF
SR11EF-5000
SR11EF-10000
SR11EF-15000
SR11WF
SR11WF-5000
SR11WF-10000
SR11WF-15000
Order No.
070 859
077 629
077 630
077 631
054 773
077 635
077 636
077 637
45
Safety switches NP/GP/TP
Bolt NP
! For NP...AS safety switches
Dimension drawing
Bolt NP for right or left hinged doors
(46
6
25
20
75
)
±1
20
125
151,5
ø6,2
Approach
direction
47
62
19
10
±1
ø6,2
Detail A
114
After adjustment,
join the parts with
a positive connection
40
Detail A
Characteristics
! Easy screw fitting to both aluminum extruded
profiles and machine guards
! Distinctive yellow color for easy recognition
! Symmetrical design for right-hinged or lefthinged doors
! No additional door handle necessary
! Automatic snap-in function to retain position
of the bolt when pushed to its locked position
(only at version Bolt 1 NP/TP)
! Snap-in mechanism prevents unintentional
opening of the hinged door
! Extended hole at the bolt permits fixing of
padlocks
! Bolt for safety switch NP...AS and TP...A is
identical
Notes
28,5
Guard
frame (40x40)
Door hung on left
! Only NP...AS can be mounted on the switch
bracket NP.
! Actuator included
! Please order safety switch and switch bracket separately
104
Ordering table
140
46
37
Article
Bolt O NP/TP
without snap-in function
Bolt 1 NP/TP
with snap-in mechanism,
1 x snap-in function closed
Switch bracket NP
Order No.
073 535
073 536
073 538
Safety switches NP/GP/TP
Bolt TP
! For GP... and TP...A safety switches
Dimension drawing
Bolt TP for right or left hinged doors
(46
6
25
75
20
)
±1
20
ø6,2
Approach
direction
47
62
25,5
10
±1
Detail A
217
114
250
ø6,2
Characteristics
Detail A
After adjustment,
join the parts with
a positive connection
40
! Easily installed to both aluminum extruded
profiles and machine guards
! Distinctive yellow color for easy recognition
! Symmetrical design for right-hinged or lefthinged doors
! No additional door handle necessary
! Automatic snap-in function to retain position
of the bolt when pushed to its locked position
(only at version Bolt 1 NP/TP)
! Snap-in mechanism prevents unintentional
opening of the hinged door
! Extended hole at the bolt permits fixing of
padlocks
Notes
34,5
Guard
frame (40x40)
Door hung on left
! The TP switch must be turned to A approach
direction for proper mounting.
! Bolt for safety switch NP...AS and TP...A
are identical
! Actuator included
! Please order safety switch and switch bracket separately
104
Ordering table
140
Article
Bolt O NP/TP
without snap-in function
Bolt 1 NP/TP
with snap-in function,
1 x snap-in function closed
Switch bracket TP
Order No.
073 535
073 536
073 539
37
47
Safety switches NP/GP/TP
Bolt with emergency release for escape from the hazardous area
Bolts with an emergency release offer the following important advantages:
! Bolts with an emergency release allow the operator to open the closed safety guard and escape from the hazardous area.
! Protection for the operator in an emergency.
If there is a risk that someone may be accidentally locked into an accessible hazardous area, the EU Machinery Directive stipulates:
“Machines must be designed, built and equipped in such a manner that the person at risk will not remain locked into the machine, or,
if this is not possible, can call for help”.
In the case of safety switches with a guard-locking device, the German trade association recommends the use of a manually operated
emergency release in accordance with BGI 575. With the emergency release, the guard-locking device can be disabled from the inside
in case of danger. The emergency release for the safety switch must be within easy reach inside the hazardous area and must be
operable without the need of any other tools.
Figure 1 shows safety switch TP... used in conjunction with bolt TP-.F with an emergency
release into the back of the switch. With this combination, the emergency release is
operated by turning lever (figure 1, A) and slide bolt (figure 1, B).
With the safety switch in normal mode (rotary lever in locked position), the operator
can start the locking process. If someone is inside the hazardous area and the door
is accidentally closed and locked, this could pose a serious threat to the individual.
B
A
Fig. 1: Safety switch with bolt (rear view)
#
By turning the lever (emergency release, figure 2, 1), the person locked in can trigger
the safety switch’s mechanical unlocking system. The solenoid monitoring contacts
are forced open. The safety circuit is interrupted and a command to stop the machine
operation is triggered.
The slide bolt (figure 2, 2) allows the actuator to be pulled out of the safety switch so
the exit door can be opened.
2
#
"
1
Fig. 2: Emergency release with lever activated
In order to prevent anyone from being locking into the hazardous area, the following
precautions should be taken when using bolt TP-.F.
! Padlock (figure 3, C)
The bolt tongue has an oblong slot which holds up to three padlocks. When service
work is being carried out, the doors cannot be locked thus the machine cannot be
started by third parties.
! Detent knob (figure 3, D)
Operators who tend to monitor the processes closely and temporary enter into the
machine pose a high level of risk.
In order to take positive action to prevent anyone from accidentally being locking
inside a hazardous area, a detent knob must be pulled to slide the actuator into the
safety switch.
48
D
C
Fig. 3: Padlock and detent knob
Safety switches NP/GP/TP
Bolt TP-.F
! For safety switches GP.../TP... and safety switches with
emergency release TP...A.-C1743 and TP...A.-C1993
! Emergency release lever to escape from out of the hazardous
area
Dimension drawing
Bolt TP-AF with emergency release for right hinged doors
40
15
110
20
20
for
M6 screw
15
35
74
171,5
14
42
60
18
30
for M6 screw
283
Adjusting
screw
safeguarded
Safety switch TP...
Approach direction A
144
M5
for M6 screw
Features
(4x)
! Bolt with snap-in
! When the bolt is open the knob snaps into
position preventing unintended closure.
30
90
Guard
frame (40 x 40)
120
305
for
M6 screw
85
69
33
10
8
Door hung
on right
(16)
1)
ca.25
58
1) Bolt with snap-in mechanism.
When the bolt is open the knob
snaps into position preventing
unintended closure. Pulling the
snap-in knob upward allows for
closure of the bolt.
135
62
Characteristics
! Easy screw fitting to both aluminum extruded
profiles and machine guards
! Distinctive yellow color for easy recognition
! Robust version for heavy doors
! No additional door handle necessary
! Extended hole at the bolt permits fixing of
padlocks
Notes
! The TP switch must be turned to A approach
direction for proper mounting.
! Actuator included
! Please order safety switch separately
Ordering table
Article
Bolt TP-AF
(with emergency release)
for right hinged doors
Bolt TP-CF
(with emergency release)
for left hinged doors
Bolt TP-A
(without emergency release)
for right hinged doors
Bolt TP-C
(without emergency release)
for left hinged doors
Order No.
086 186
086 188
084 430
084 432
49
Safety switches NP/GP/TP
Mounting plates EMP for TP...A Safety Switches
Switch
Switch
mounting
type
Switch
mounting plate
Actuator
mounting plate
EMP-SB
Order No.
093 456
TP...A
A
vertical
EMP-B1
Order No.
093 457
45
Minimum distance
hinged actuator
to switch
Order No.
070 038
074 577
Angle
actuator
> 1000 mm
46
43
M4 (4x)
4
83
Actuator
see page
38 - 40
M5 (4x)
M5 (8x)
Order No.
059 440
074 573
> 100 mm
180
162
56
4
M5 x 10
EMP-B2
Order No.
093 458
B
horizontal
Order No.
070 050
074 572
> 90 mm
6,5
70
M5 (2x)
50
M5 x 25
Mounting A, safety switch vertical
A
TP
Mounting B, safety switch horizontal
B
30-50
TP
30-50
Note
B Mounting plate material: St37 galvanized.
B The EMP mounting plate is suitable for the TP...A safety switch only. The TP...K safety switch (with adapter) is not usable in
combination with the mounting plates.
B The EMP-SB mounting plate is also suitable for the TP...C1743 and TP...C1993 safety switches with emergency release from the
rear.
50
Safety switches NP/GP/TP
Index sorted by article
Article
ADAPTER NP-K
ACTUATOR-P-G
ACTUATOR-P-GN
ACTUATOR-P-GNT
ACTUATOR-P-GT
ACTUATOR-P-W
ACTUATOR-P-WN
ACTUATOR-P-WNT
ACTUATOR-P-WT
BOLT 0 NP / TP
BOLT 0 NP / TP
BOLT 1 NP / TP
BOLT 1 NP / TP
BOLT TP-A
BOLT TP-AF
BOLT TP-C
BOLT TP-CF
BUILT-IN LED
10m connection cable with M12 (8-pole)
15m connection cable with M12 (8-pole)
20m connection cable with M12 (8-pole)
25m connection cable with M12 (8-pole)
50m connection cable with M12 (8-pole)
5m connection cable with M12 (8-pole)
EKPM20/06
EMP-B1
EMP-B2
EMP-SB
3X30/V100
3X30/V100
3X38/V100
GP1-528A-M
GP1-538A-M
GP1-2121A-M
GP1-2131A-M
GP1-3131A-M
HINGED ACTUATOR P-LR
HINGED ACTUATOR P-LRN
HINGED ACTUATOR P-OU
HINGED ACTUATOR P-OUN
IDENTICAL LOCK TP
INSERTION FUNNEL NP / TP
LATCH SPRING NP / TP
LOCKOUT BAR P
M4X14/V100
M5X10/V100
M5X25/V100
NP1-618AB-M
NP1-618AS-M
NP1-628AB-M
NP1-628AS-M
NP1-638AB-M
NP1-638AS-M
NP1-648AB-M
NP1-648AS-M
NP2-628AB
NP2-628AS
NP2-638AB
NP2-638AS
REPLACEMENT KEYS FOR IDENTICAL LOCKS
SR11EF
SR11EF-10000
SR11EF-15000
SR11EF-5000
SR11WF
SR11WF-10000
SR11WF-15000
SR11WF-5000
SR6EF
Order No. Page
074578
43
059226
38
074570
39
074576
40
070046
40
059227
38
074571
39
074577
40
070038
40
073535
46
073535
47
073536
46
073536
47
084430
49
086186
49
084432
49
086188
49
087423
43
077752
44
077753
44
077871
44
077872
44
077873
44
077751
44
086233
44
093457
50
093458
50
093456
50
075532
41
082237
41
076755
41
089725
11
090250
11
090252
11
090255
11
090258
11
059440
38
074573
39
070050
38
074572
39
086236
42
086237
42
076501
41
070651
41
086232
41
086231
41
073457
41
083680
9
083685
9
083686
9
083688
9
083690
9
083691
9
082276
9
082280
9
059448
9
059447
9
059450
9
059449
9
077206
42
070859
45
077630
45
077631
45
077629
45
054773
45
077636
45
077637
45
077635
45
013176
45
Article
SR6EF-10000
SR6EF-15000
SR6EF-5000
SR6WF
SR6WF-10000
SR6WF-15000
SR6WF-5000
SWITCH BRACKET NP
SWITCH BRACKET TP
TP1-4131A024M
TP1-4131A024SR11
TP1-4131A110M
TP1-4131A230M
TP1-4131K024M
TP1-4131K024SR11
TP1-4131K110M
TP1-4131K230M
TP1-528A024M
TP1-528A024SR6
TP1-528A110M
TP1-528A110SR6
TP1-528A230M
TP1-528A230SR6
TP1-528K024M
TP1-528K024SR6
TP1-538A024M
TP1-538A024SR6
TP1-538A110M
TP1-538A110SR6
TP1-538A230M
TP1-538A230SR6
TP1-538K024M
TP1-538K024SR6
TP2-4131A024M
TP2-4131A024SR11
TP2-4131A110M
TP2-4131A230M
TP2-4131K024M
TP2-4131K024SR11
TP2-528A024M
TP2-528A024SR6
TP2-528A110M
TP2-528A110SR6
TP2-528A230M
TP2-528A230SR6
TP2-528K024M
TP2-528K024SR6
TP2-538A024M
TP2-538A024SR6
TP2-538A110M
TP2-538A110SR6
TP2-538A230M
TP2-538A230SR6
TP2-538K024M
TP2-538K024SR6
TP3-2131A024M
TP3-2131A024MC1743
TP3-2131A024MC1761
TP3-2131A024MC1993
TP3-2131A024SR11
TP3-2131A110M
TP3-2131A230M
TP3-2131K024M
TP3-2131K024SR11
TP3-2131K230M
TP3-4121A024M
TP3-4121A024MC1743
TP3-4121A024SR11
TP3-4121A110M
Order No. Page
077633
45
077634
45
077632
45
024999
45
077639
45
077640
45
077638
45
073538
46
073539
47
084115
21
088202
21
084116
21
084117
21
084150
23
088217
23
084254
23
084255
23
084295
17
087431
17
084300
17
087435
17
084304
17
087438
17
084342
19
088210
19
084310
17
087433
17
084315
17
087436
17
084320
17
087439
17
084343
19
088212
19
084125
21
088203
21
084126
21
084128
21
084253
23
088218
23
084325
17
087441
17
084330
17
087444
17
084332
17
087448
17
084344
19
088214
19
084333
17
087442
17
084334
17
087446
17
084335
17
087449
17
084346
19
088215
19
084142
25
084285
32
084290
31
087400
33
088205
25
084143
25
084144
25
084264
27
088220
27
084265
27
084135
25
087427
32
088206
25
084137
25
51
Safety switches NP/GP/TP
Index sorted by catalogue number
Article
TP3-4121A230M
TP3-4121K024M
TP3-4121K024SR11
TP3-4121K230M
TP3-4131A024M
TP3-4131A024SR11
TP3-4131A110M
TP3-4131A230M
TP3-4131K024M
TP3-4131K024SR11
TP3-4131K110M
TP3-4131K230M
TP3-4141A024M
TP3-4141A024MC1742
TP3-4141A024SR11
TP3-4141HA024SM4C2012
TP3-4141HA024SM4C2013
TP3-4141HA024SM8C1992
TP3-537A024M
TP3-537A024SR6
TP3-537A110M
TP3-537A110SR6
TP3-537A230M
TP3-537A230SR6
TP3-537K024M
TP3-537K024SR6
TP4-2131A024M
TP4-2131A024SR11
TP4-2131A110M
TP4-2131A230M
TP4-2131K024M
TP4-2131K024SR11
TP4-4121A024M
TP4-4121A024SR11
TP4-4121A110M
TP4-4121A230M
TP4-4121K024M
TP4-4121K024SR11
TP4-4131A024M
TP4-4131A024SR11
TP4-4131A110M
TP4-4131A230M
TP4-4131K024M
TP4-4131K024SR11
TP4-4141A024M
TP4-4141HA024SM4C2012
TP4-4141HA024SM8 C1992
TP4-537A024M
TP4-537A024SR6
TP4-537A110M
TP4-537A110SR6
TP4-537A230M
TP4-537A230SR6
TP4-537K024M
TP4-537K024SR6
TP4-537K110M
TP5-4120A024M
TP6-4120A024M
UNIQUE LOCK TP
52
Order No. Page
084138
25
084260
27
088221
27
084262
27
084129
25
088204
25
084130
25
084131
25
084256
27
088219
27
084257
27
084258
27
084270
30
086165
32
088922
30
087425
37
087426
37
087377
35
084336
17
087434
17
084337
17
087437
17
084338
17
087440
17
084347
19
088213
19
084145
25
088208
25
084147
25
084148
25
084266
27
088223
27
084139
25
088209
25
084140
25
084141
25
084263
27
088224
27
084132
25
088207
25
084133
25
084134
25
084259
27
088222
27
084275
30
092772
37
087378
35
084339
17
087443
17
084340
17
087447
17
084341
17
087450
17
084348
19
088216
19
084349
19
084279
29
084280
29
084177
42
Order No. Article
013176 SR6EF
024999 SR6WF
054773 SR11WF
059226 ACTUATOR-P-G
059227 ACTUATOR-P-W
059440 HINGED ACTUATOR P-LR
059447 NP2-628AS
059448 NP2-628AB
059449 NP2-638AS
059450 NP2-638AB
070038 ACTUATOR-P-WT
070046 ACTUATOR-P-GT
070050 HINGED ACTUATOR P-OU
070651 LOCKOUT BAR P
070859 SR11EF
073457 M5X25/V100
073535 BOLT 0 NP / TP
073535 BOLT 0 NP / TP
073536 BOLT 1 NP / TP
073536 BOLT 1 NP / TP
073538 SWITCH BRACKET NP
073539 SWITCH BRACKET TP
074570 ACTUATOR-P-GN
074571 ACTUATOR-P-WN
074572 HINGED ACTUATOR P-OUN
074573 HINGED ACTUATOR P-LRN
074576 ACTUATOR-P-GNT
074577 ACTUATOR-P-WNT
074578 ADAPTER NP-K
075532 3X30/V100
076501 LATCH SPRING NP / TP
076755 3X38/V100
077206 REPLACEMENT KEYS FOR IDENTICAL LOCKS
077629 SR11EF-5000
077630 SR11EF-10000
077631 SR11EF-15000
077632 SR6EF-5000
077633 SR6EF-10000
077634 SR6EF-15000
077635 SR11WF-5000
077636 SR11WF-10000
077637 SR11WF-15000
077638 SR6WF-5000
077639 SR6WF-10000
077640 SR6WF-15000
077751 5m connection cable with M12 (8-pole)
077752 10m connection cable with M12 (8-pole)
077753 15m connection cable with M12 (8-pole)
077871 20m connection cable with M12 (8-pole)
077872 25m connection cable with M12 (8-pole)
077873 50m connection cable with M12 (8-pole)
082237 3X30/V100
082276 NP1-648AB-M
082280 NP1-648AS-M
083680 NP1-618AB-M
083685 NP1-618AS-M
083686 NP1-628AB-M
083688 NP1-628AS-M
083690 NP1-638AB-M
083691 NP1-638AS-M
084115 TP1-4131A024M
084116 TP1-4131A110M
084117 TP1-4131A230M
084125 TP2-4131A024M
084126 TP2-4131A110M
084128 TP2-4131A230M
084129 TP3-4131A024M
084130 TP3-4131A110M
084131 TP3-4131A230M
Page
45
45
45
38
38
38
9
9
9
9
40
40
38
41
45
41
46
47
46
47
46
47
39
39
39
39
40
40
43
41
41
41
42
45
45
45
45
45
45
45
45
45
45
45
45
44
44
44
44
44
44
41
9
9
9
9
9
9
9
9
21
21
21
21
21
21
25
25
25
Safety switches NP/GP/TP
Order No. Article
084132 TP4-4131A024M
084133 TP4-4131A110M
084134 TP4-4131A230M
084135 TP3-4121A024M
084137 TP3-4121A110M
084138 TP3-4121A230M
084139 TP4-4121A024M
084140 TP4-4121A110M
084141 TP4-4121A230M
084142 TP3-2131A024M
084143 TP3-2131A110M
084144 TP3-2131A230M
084145 TP4-2131A024M
084147 TP4-2131A110M
084148 TP4-2131A230M
084150 TP1-4131K024M
084177 UNIQUE LOCK TP
084253 TP2-4131K024M
084254 TP1-4131K110M
084255 TP1-4131K230M
084256 TP3-4131K024M
084257 TP3-4131K110M
084258 TP3-4131K230M
084259 TP4-4131K024M
084260 TP3-4121K024M
084262 TP3-4121K230M
084263 TP4-4121K024M
084264 TP3-2131K024M
084265 TP3-2131K230M
084266 TP4-2131K024M
084270 TP3-4141A024M
084275 TP4-4141A024M
084279 TP5-4120A024M
084280 TP6-4120A024M
084285 TP3-2131A024MC1743
084290 TP3-2131A024MC1761
084295 TP1-528A024M
084300 TP1-528A110M
084304 TP1-528A230M
084310 TP1-538A024M
084315 TP1-538A110M
084320 TP1-538A230M
084325 TP2-528A024M
084330 TP2-528A110M
084332 TP2-528A230M
084333 TP2-538A024M
084334 TP2-538A110M
084335 TP2-538A230M
084336 TP3-537A024M
084337 TP3-537A110M
084338 TP3-537A230M
084339 TP4-537A024M
084340 TP4-537A110M
084341 TP4-537A230M
084342 TP1-528K024M
084343 TP1-538K024M
084344 TP2-528K024M
084346 TP2-538K024M
084347 TP3-537K024M
084348 TP4-537K024M
084349 TP4-537K110M
084430 BOLT TP-A
084432 BOLT TP-C
086165 TP3-4141A024MC1743
086186 BOLT TP-AF
086188 BOLT TP-CF
086231 M5X10/V100
086232 M4X14/V100
086233 EKPM20/06
Page
25
25
25
25
25
25
25
25
25
25
25
25
25
25
25
23
42
23
23
23
27
27
27
27
27
27
27
27
27
27
30
30
29
29
32
31
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
19
19
19
19
19
19
19
49
49
32
49
49
41
41
44
Order No. Article
086236 IDENTICAL LOCK TP
086237 INSERTION FUNNEL NP / TP
087377 TP3-4141HA024SM8C1992
087378 TP4-4141HA024SM8 C1992
087400 TP3-2131A024MC1993
087423 BUILT-IN LED
087425 TP3-4141HA024SM4C2012
087426 TP3-4141HA024SM4C2013
087427 TP3-4121A024MC1743
087431 TP1-528A024SR6
087433 TP1-538A024SR6
087434 TP3-537A024SR6
087435 TP1-528A110SR6
087436 TP1-538A110SR6
087437 TP3-537A110SR6
087438 TP1-528A230SR6
087439 TP1-538A230SR6
087440 TP3-537A230SR6
087441 TP2-528A024SR6
087442 TP2-538A024SR6
087443 TP4-537A024SR6
087444 TP2-528A110SR6
087446 TP2-538A110SR6
087447 TP4-537A110SR6
087448 TP2-528A230SR6
087449 TP2-538A230SR6
087450 TP4-537A230SR6
088202 TP1-4131A024SR11
088203 TP2-4131A024SR11
088204 TP3-4131A024SR11
088205 TP3-2131A024SR11
088206 TP3-4121A024SR11
088207 TP4-4131A024SR11
088208 TP4-2131A024SR11
088209 TP4-4121A024SR11
088210 TP1-528K024SR6
088212 TP1-538K024SR6
088213 TP3-537K024SR6
088214 TP2-528K024SR6
088215 TP2-538K024SR6
088216 TP4-537K024SR6
088217 TP1-4131K024SR11
088218 TP2-4131K024SR11
088219 TP3-4131K024SR11
088220 TP3-2131K024SR11
088221 TP3-4121K024SR11
088222 TP4-4131K024SR11
088223 TP4-2131K024SR11
088224 TP4-4121K024SR11
088922 TP3-4141A024SR11
088923 TP4-4141A024SR11
089725 GP1-528A-M
090250 GP1-538A-M
090252 GP1-2121A-M
090255 GP1-2131A-M
090258 GP1-3131A-M
092772 TP4-4141HA024SM4C2012
093456 EMP-SB
093457 EMP-B1
093458 EMP-B2
Page
42
42
35
35
33
43
37
37
32
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
17
21
21
25
25
25
25
25
25
19
19
19
19
19
19
23
23
27
27
27
27
27
27
30
30
11
11
11
11
11
37
50
50
50
53
Repr
esent
ation int
ern
ation
al
epre
sentation
intern
ernation
ational
Australia
Micromax Pty. Ltd.
PO Box 1238
AUS-Wollongong
NSW Australia 2500
Tel. +61 (0) 2 4271 1300
Fax +61 (0) 2 4271 8091
micromax@micromax.com.au
Austria
EUCHNER Ges. mbH
Süddruckgasse 4
A-2512 Tribuswinkel
Tel. +43 (0) 22 52 4 21 91
Fax +43 (0) 22 52 4 52 25
info@euchner.at
Benelux
EUCHNER (BENELUX) B.V.
Postbus 119
NL-3350 AC Papendrecht
Tel. +31 (0) 78 6 15 47 66
Fax +31 (0) 78 6 15 43 11
info@euchner.nl
Brazil
EUCHNER Itda.
Av. Prof. Luiz Ignacio Anhaia
Mello no. 4387
S. Lucas
São Paulo SP Brasil
CEP 03295-000
Tel. +55 (0) 11 69 18-22 00
Fax +55 (0) 11 61 01-06 13
euchner@euchner.com.br
Canada
IAC & Associates Inc.
1925 Provincial Road
Windsor, Ontario N9A 6J3
Tel. +1 (5 19) 966-3444
Fax +1 (5 19) 966-6160
sales@iacnassociates.com
China
Knowhow I&C Co
Rm 1106,
Science and Technology
Building No. 11
Baishiqiao Rd.
Beijing, 100081
Tel. +86 (0) 10 6846 6483
Fax +86 (0) 10 6891 4989
knowhow@public3.bta.net.cn
Czech Republic
Amtek spol s.r.o.
.
.
Elektronicke Soucastky
ˆ
Automatizacni Technika
.
Presne strojìrenstvi
Videnská 125
CZ-619 00 Brno
Ceská republika
Tel. +420 5 47 12 55 70
Fax +420 5 47 12 55 56
amtek@amtek.cz
ˆ
ˆ
ˆ
Denmark
Robotek EL & TEKNIK A/S
Blokken 31, Postboks 30
DK-3460 Birkerød
Tel. +45 44 84 73 60
Fax +45 44 84 41 77
info@robotek.dk
54
Eastern Europe
Hera Handels Ges. mbH
Hauptstraße 61
A-2391 Kaltleutgeben
Tel. +43 (0) 22 38 7 75 18
Fax +43 (0) 22 38 7 75 28
hera@telering.at
Finland
Sähkölehto Oy
Lehto & Co.
Holkkitie 14
FIN-00880 Helsinki
Tel. +358 (0) 9 774 6420
Fax +358 (0) 9 759 1071
office@sahkolehto.fi
France
EUCHNER France S.A.R.L.
Immeuble Le Colorado
ERAGNY PARC
Rue Rosa Luxembourg
Parc d'affaires des Bellevues
F-95610 ERAGNY sur OISE
Tel. +33 (0) 1 39 09 90 90
Fax +33 (0) 1 39 09 90 99
info@euchner.fr
Hong Kong
Imperial Engineers &
Equipment Co. Ltd.
Unit B 12th Floor
Cheung Lee Industrial Building
9 Cheung Lee Street
HK-Chaiwan, Hong Kong
Tel. +8 52/28 89 02 92
Fax +8 52/28 89 18 14
ieeclhk@netvigator.com
Hungary
EUCHNER Ges.mbH
Magyarországi Fióktelep
H-2045 Törökbálint
Tópark Ipari park 3301/28
Feketerét u. 1.
Tel. +36/23/428 374
Fax +36/23/428 375
info@euchner.hu
India
Teknic Controlgear PVT Ltd.
703, Madhava,
Bandra Kurla Complex
Bandra East
IND-Mumbai 400051
Tel. +91 (0) 22 654 2392
+91 (0) 22 654 2393
+91 (0) 22 654 2396
Fax +91 (0) 22 654 2391
teknic@vsnl.com
Iran
INFOCELL IRAN Co.
# 84, Manoucheri Ave.,
P.O. Box 81655-861, Isfahan, IRAN
Tel. +98 311 221 1358
Fax +98 311 222 6176
info@infocell-co.com
Italy
TRITECNICA S.r.l.
Viale Lazio 26
I-20135 Milano
Tel. +39 02 54 194-1
Fax +39 02 55 01 04 74
info@tritecnica.it
Japan
Solton Co. Ltd.
2-13-7, Shin-Yokohama
Kohoku-ku, Yokohama
Japan 222-0033
Tel. +81 (0) 45 4 71 77 11
Fax +81 (0) 45 4 71 77 17
sales@solton.co.jp
Korea
EUCHNER Korea Ltd.
RM 810 Daerung Technotown
#448 Gasan-Dong
Kumchon-Gu, Seoul
Tel. +82 (02) 2107 3500
Fax +82 (02) 2107 3999
sijang@euchner.co.kr
Mexico
SEPIA S.A. de C.V.
Maricopa # 10
302, Col. Napoles.
Del. Benito Juarez
MEX-03810 Mexico D:F:
Tel. +52 (5) 6822 347
Fax +52 (5) 5367 787
sepia@prodigy.net.mx
New Zealand
WAF, W. Arthur Fisher
11 Te Apunga Place
Mt. Wellington
Aukland, New Zealand
Tel. +64 (0) 9 270 0100
Fax +64 (0) 9 270 0900
chrisl@waf.co.nz
Norway
ELIS ELEKTRO AS
Postboks 38
Lindeberg gard
N-1007 Oslo
Tel. +47 (22) 90 56 70
Fax +47 (22) 90 56 71
post@eliselektro.no
Poland
ELTRON
pl. Wolnosci
´ 7B
PL 50-071 Wroclaw
´
Tel. +48 (0)71 343 97 55
Fax +48 (0)71 343 96 64
LP@eltron.pl
Portugal
PAM – Serviços Técnicos
Industriais, Lda
Rua Senhora da Alegria 188
P-4785 Alvarelhos STS
Tel. +3 51 (0) 22 98 27 518
Fax +3 51 (0) 22 98 27 519
pam@mail.telepac.pt
Singapore
SENTRONICS
Automation and Marketing Pte Ltd
Blk 3021 Ubi Avenue 2
# 03-169
SGP-Singapore 408897
Tel. +65/6744 8018
Fax +65/6744 1929
sentronics@pacific.net.sg
Slovenia
SMM d.o.c.
Production Systems Ltd.
Jaskova 1E
SLO-2001 Maribor
Slovenia
Tel. +386 (0)2 450 23 26
Fax +386 (0)2 462 51 60
franc.kit@smm.si
Spain
EUCHNER, S.L.
Av. de Zarauz, 84-Bajo
P.O. Box 224
E-20009 San Sebastian
Tel. +34 (9 43) 31 67 60
Fax +34 (9 43) 31 64 05
euchner@edunet.es
Sweden
Censit AB
Box 331
S-33123 Värnamo
Tel. +46 (0) 3 70 69 10 10
Fax +46 (0) 3 70 188 88
info@censit.se
Switzerland
EUCHNER AG
Ing.- und Vertriebsbüro
Grofstraße 17
CH-8887 Mels/St. Gallen
Tel. +41 (0) 81 7 20 45 90
Fax +41 (0) 81 7 20 45 99
euchner.schweiz@bluewin.ch
Taiwan
Daybreak International
(Taiwan) Corp.
3 Fl., 124 Chung-Cheng Road
Shihlin
Taipei, Taiwan
Tel. +8 86 (0) 2 8 866 1231
Fax +8 86 (0) 2 8 866 1239
day111@ms23.hinet.net
Turkey
PINAR MÜHENDISLIK SAN.
ve Tic. Ltd. Sti.
Perpa Tic. Merkezi
Kat. 11, No. 1705
TR-80270 Okmeydani/lstanbul
Tel. +90 (0) 2 12 2 20 02 77
Fax +90 (0) 2 12 2 20 13 16
pinarmuh@superonline.com
United Kingdom
EUCHNER (U.K.) Ltd.
Unit 2, Petre Drive,
GB-Sheffield, S4 7PZ
Tel. +44 (0) 1 14 2 56 01 23
Fax +44 (0) 1 14 2 42 53 33
info@euchner.co.uk
USA
EUCHNER USA Inc.
6723 Lyons St.
USA-E. Syracuse, NY 13057
Tel. +1 (3 15) 7 01-03 15
Fax +1 (3 15) 7 01-03 19
info@euchner-usa.com
He
ad offic
e
Hea
office
EUCHNER GmbH + Co. KG
Kohlhammerstraße 16
D-70771 Leinfelden-Echterdingen
Germany
Tel. +49/7 11/75 97-0
Fax +49/7 11/75 33 16
info@euchner.de
www
hner
www..euc
euchner
hner..com
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More Automation
than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More Safety
than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More ManMachine
than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
than safety. More than safety. More
safety. More than safety. More than
More than safety. More than safety.
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
than safety. More
safety. More than
More than safety.
55
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor
than
safe
Mor