Document Record
No.
Date
1 2014.02.14
Modified Content
Page
Draft
6
D
Runsong Zhong
Lianghua Guo
6
B/0
Kings Luo
Wenhua Yan
2 2014.04.08 Added TUV certification
3 2015.02.04
Add 125mA and 250mA
CQC certification;
4,15,16
Add 200mA I-T Curve
Edition Prepared/modified by
B/1
Kings Luo
Checked by
Wenhua Yan
4 2015.02.09
Add 8A and 10A CQC
certification;
19,20
B/2
Kings Luo
Wenhua Yan
5 2015.06.18
The fuse high to change
the 7.6mm
5
B/3
Jeffery
Gem Guo
B/4
Jeffery
Gem Guo
B/5
Jeffery
Gem Guo
B/6
Jeffery
Lin Gao
9 2015.12.12 Update PSE certification
B/7
Jeffery
Lin Gao
10 2016.01.14
Update I2T value
B/8
Jeffery
Wenhua Yan
11 2016.04.15
Add the 0.16A~0.4A
CQC certification
B/9
Jeffery
Helge
B/10
Jeffery
Wenqiang Luo
C/0
J.Q.
Fei Gao
C/1
J.Q.
Fei Gao
6 2015.08.04 Update UR certification
7 2015.09.09
Update CQC , TUV
certification
8 2015.11.18
Update the tapping
9
3,7
12 2016.8.24 Change the construction
13 2017.12.08
Update BSI,SEMKO
certification
14 2018.03.05 Update TUV certification
15 2018.10.08 Change of the innor core
and material
4
C/2
Xiang Xiong
Fei Gao
16 2019.02.25 Update UL certification
7
C/3
Xiang Xiong
Fei Gao
17 2019.03.11 Add 6.3A PSE certification
7
C/4
Xiang Xiong
Fei Gao
Add 12A,12.5A,15A
18 2019.04.24 and16A IT curve
6
C/5
Xiang Xiong
Fei Gao
19 2019.10.14
Change CQC to CCC
D/0
YaLan Wang
Fei Gao
20 2020.04.23
Update tape drawing
D/1
YaLan Wang
Fei Gao
D/2
YaLan Wang
Fei Gao
21 2020.04.24 Add 300V CQC certification
TABLE OF CONTENTS
1. SCOPE AND DESCRIPTION............................................................................................................ 3
2. GENERAL INFORMATION................................................................................................................3
3. AGENCY APPROVALS......................................................................................................................3
4. PART NUMBERING SYSTEM.......................................................................................................... 4
5. CONSTRUCTION AND MECHANICAL CHARACTERISTICS.................................................... 5
6. ELECTRICAL SPECIFICATIONS.................................................................................................... 6
7. SOLDERING PARAMETERS........................................................................................................... 8
8. ORDERING INFORMATION..............................................................................................................8
9. PACKING INFORMATION.................................................................................................................9
10.APPENDIX..........................................................................................................................................10
2
932 / OC FUSE
1. SCOPE AND DESCRIPTION
Following electronic product specifications apply to fuses of the
932 series. The 932 series is a sub miniature fuse links for overcurrent protection.
Its main applications are for consumer electronics, LED drivers,
power supplies, battery chargers and controllers for industrial use.
2. GENERAL INFORMATION
General Description
The 932 series provides protection for printed circuit boards used in a large variety of
applications that need fuses with time-delay, low breaking capacity. The sub-miniature device is
constructed of a plastic cap and base with a tin plated copper lead wire. It offers excellent
mounting characteristics and is 100% tested for cold resistance.
Detailed Features
• Subminiature fuse with time delay, low breaking capacity
• Small, rectangular and leaded design minimizes board space and eliminates the need for
additional mounting components
• Plastic cap / brown thermoplastic fuse body.
• 0.6mm lead wires made of tin plated copper.
• Protection against harmful over-currents in primary and secondary applications.
• Lead-free, Halogen-free, RoHS compliant
• Designed according to IEC 60127-3
• TUV compliance to EN 60127-7: 2016
3. AGENCY APPROVALS
Agency
Agency File Number
Voltage/ Current Rating
400/300/277/250/125V AC: 0.1A~16A;
E300003
250V AC:125mA;160mA;200mA;250mA;315mA
400mA;500mA;630mA;800mA;1A;1.25A
1.6A;2A;2.5A;3.15A;4A;5A;6.3A;8A;10A
2019010207235037
PSE15020937
PSE19021462
250V AC: 1A, 1.25A, 1.6A, 2A, 2.5A, 3.15A, 4A, 5A,
250V AC: 6.3A
250V AC: 630mA, 800mA, 1A, 1.25A, 1.6A, 2A, 2.5A,
3.15A, 4A, 5A, 6.3A
40033369
SU05042-13003,
SU05042-13002,
SU05042-13001
250V AC: 500mA, 630mA, 800mA, 1A, 1.25A, 1.6A,
2A, 2.5A, 3.15A, 4A, 5A, 6.3A
300V AC:500mA;1A;1.25A;1.6A;2A;2.5A;3.15A;4A;5A;
CQC20012242947
6.3A;8A;10A
3
932 / OC FUSE
R 50279350
300V AC: 125mA, 160mA,200mA, 250mA, 315mA,
400mA, 500mA, 630mA, 800mA, 1A, 1.25A, 1.6A,
2A, 2.5A, 3.15A, 4A, 5A, 6.3A, 8A, 10A
250V AC: 125mA, 160mA,200mA, 250mA, 315mA,
400mA, 500mA,
KM 677189
250V AC:3.15A;5A;8A;10A
1719061
250V AC:3.15A;5A;8A;10A
4. PART NUMBERING SYSTEM
4.1 Part Number
Example: 9321315278
932
1315
2
78
1
2
3
4
1 .Product Series …………..................
2 .Ampere Rating ……………..............
3 .Rated Voltage …………...................
932
3.15A (see table 4.2 below)
1– 125V
2– 250V
3– 300V
K– 400V
4 .Supplementary Code ………...........
Complement Code
4.2. Ampere / Voltage Rating Table
AMP CODE
CURRENT RATING
VOLTAGE RATING
0100
100mA
125 / 250 / 277/ 300/ 400V AC
0125
125mA
125 / 250 / 277/ 300/ 400V AC
0160
160mA
125 / 250 / 277/ 300/ 400V AC
0200
200mA
125 / 250 / 277/ 300/ 400V AC
0250
250mA
125 / 250 / 277/ 300/ 400V AC
0315
315mA
125 / 250 / 277/ 300/ 400V AC
0400
400mA
125 / 250 / 277/ 300/ 400V AC
0500
500mA
0630
630mA
125 / 250 / 277/ 300/ 400V AC
125 / 250 / 277/ 300/ 400V AC
0800
800mA
1100
1.00A
125 / 250 / 277/ 300/ 400V AC
125 / 250 / 277/ 300/ 400V AC
1125
1.25A
125 / 250 / 277/ 300/ 400V AC
1160
1.60A
125 / 250 / 277/ 300/ 400V AC
1200
2.00A
125 / 250 / 277/ 300/ 400V AC
1250
2.50A
125 / 250 / 277/ 300/ 400V AC
1315
3.15A
1400
4.00A
125 / 250 / 277/ 300/ 400V AC
125 / 250 / 277/ 300/ 400V AC
1500
5.00A
125 / 250 / 277/ 300/ 400V AC
1630
6.30A
125 / 250 / 277/ 300/ 400V AC
1700
7.00A
125 / 250 / 277/ 300/ 400V AC
1800
8.00A
125 / 250 / 277/ 300/ 400V AC
4
932 / OC FUSE
2100
10.00A
125 / 250 / 277/ 300/ 400V AC
2120
12.00A
125 / 250 / 277/ 300/ 400V AC
2125
12.50A
125 / 250 / 277/ 300/ 400V AC
2150
15.00A
125 / 250 / 277/ 300/ 400V AC
2160
16.00A
125 / 250 / 277/ 300/ 400V AC
5. CONSTRUCTION AND MECHANICAL CHARACTERISTICS
Construction (cross section)
Melting
Soldering
Sand
Inner Core
Plastic shell
Lead
Dimensions (units: mm)
8.3±0.2
4.1±0.2
Operating Temperature:
Storage Conditions:
Min0.5
7.6±0.40
-55°C to +125°C
+10℃ to +60℃
Relative humidity: ≤ 75% yearly average
without dew, maximum 30 days at 95%
Vibration Resistance:
18.8±1.5mm
0.60±0.1
24 cycles at 15 min. each (60068-6)
10-60Hz at 0.75mm amplitude
60-2000Hz at 10g acceleration
5.08±0.1
Long Leads: L=18.8±1.5mm
Short Leads: L=4.3±0.3mm
5
932 / OC FUSE
6. ELECTRICAL SPECIFICATIONS
Time vs Current Characteristics Table
(measured with constant current power supply)
Time vs Current Characteristics: IEC 60127-3/Ⅳ
Rated Current
100mA~6.3A
150%
>1h
210%
1h
1h