HARAX ®
Contents
Page
Technical characteristics circular connector with HARAX ® rapid termination
50.02
Circular connector M8/M12 with HARAX ® rapid termination . . . . . . . . . . .
50.05
Han® M12 panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.08
Han® M12 pcb adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.10
microFX® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.12
Han ® 7/8’’ circular connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.16
Han® M12 circular connector with crimp termination . . . . . . . . . . . . . . . . . .
50.17
HARAX ® panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.18
Han® M8 and Han® M12 system cable . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.23
Circular connector 7/8“ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.35
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
50.37
HARAX ® 7/8“
Han® M12-Crimp
HARAX
50
.
01
®
HARAX Circular connector
Technical characteristics
Specifications
Approval
IEC 60 352-4
IEC 61 076-2-101
IEC 61 076-2-104
HARAX ® M8-S/
HARAX ® M8-S
(0.08 mm²)
M12-S
32 V
32 V
HARAX ® M12
angled
32 V
HARAX ® M12-L
3 poles, 4 poles
50 V
HARAX ® M12-L
screened version, A-coded
50 V
2A
4A
4A
6A
4A
Conductor
cross section
0.08 - 0.14 mm²
AWG 28 - 26
0.14 - 0.34 mm²
AWG 26 - 22
0.25 - 0.5 mm²
AWG 24/7 - 20
0.34 - 0.75 mm²
AWG 22 - 18
0.14 - 0.34 mm²
AWG 26 - 22
Diameter of individual strands
Conductor insulation material
Conductor diameter
0.05 mm
PVC / PP / TPE
0.6 - 1.0 mm
0.1 mm
PVC / PP / TPE
1.0 - 1.6 mm
M8-S: 2.5 - 5.1 mm
1.9 - 2.5 mm (transp.) M12-S:
2.5 - 3.5 mm (grey)
2.5 - 4.0 mm (transp.)
4.0 - 5.1 mm (black)
- 25 °C / + 85 °C
- 25 °C / + 85 °C
0.1 mm
PVC
1.2 - 1.6 mm
0.1 mm
PVC
1.6 - 2.0 mm
0.1 mm
PVC
1.2 - 1.6 mm
4 - 5.1 mm
3 poles: 5.5 - 7.2 mm 7 - 8.8 mm
4 poles: 6 - 8 mm
- 25 °C / + 85 °C
- 25 °C / + 85 °C
- 25 °C / + 85 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C - 5 °C … + 50 °C
- 5 °C … + 50 °C
IP 67
IP 67
IP 67
IP 65 / IP 67
IP 67
10
10
10
10
10
0.4 Nm / SW 9
M8-S: 0.4 Nm / SW 9 0.6 Nm / SW 13
M12-S: 0.6 Nm / SW 13
0.6 Nm / SW 17
0.6 Nm / SW 17
Construction type
Rated voltage
Rated current
(see current carrying capacity)
Cable diameter
Limiting temperatures
Temperature during
connection
Degree of protection
Termination cycles with
the same cross section
Recommended tightening
torque / Hexagonal wrench
Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded
contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum
temperature.
Control and test procedures according to DIN IEC 60 512-5.
M8-S, 4 poles 1 = wire gauge 0.25 mm²
M12-S, 4 poles 2 = wire gauge 0.34 mm²
Rated current [A]
wire gauge 1.4 mm²
Rated current [A]
M8-S, 3 poles
Ambient temperature [oC]
M12-L
3 poles, 4 poles
1 = wire gauge 0.34 mm²
2 = wire gauge 0.75 mm²
Rated current [A]
50
.
02
M12, 4 poles,
angled
1 = wire gauge 0.25 mm²
2 = wire gauge 0.5 mm²
Rated current [A]
HARAX
Ambient temperature [oC]
Ambient temperature [oC]
Ambient temperature [oC]
®
HARAX Circular connector
Technical characteristics
Specifications
Approval
IEC 60 352-4
IEC 61 076-2-101
IEC 61 076-2-104
Construction type
Rated voltage
Rated current
(see current carrying capacity)
Conductor
cross section
Diameter of individual strands
Conductor insulation material
Conductor diameter
Cable diameter
Limiting temperatures
Temperature during
connection
Degree of protection
Termination cycles with
the same cross section
Recommended tightening
torque / Hexagonal wrench
HARAX ® M12-L screened version
Ethernet
PROFIBUS
50 V
32 V
4A
4A
0.25 - 0.34 mm²
AWG 24- 22
0.75 - 1.5 mm²
AWG 18 - 16
0.1 mm
PVC, Zell-PE
2 - 2.6 mm
0.15 mm
PVC, PP, TPE
2.8 mm
Han ® 7/8“
230 V / 400 V
HARAX ® M12-L
5 poles
50 V
Han ® M12
Crimp
50 V
10 A
4A
4A
À 0.14 - 0.34 mm²
AWG 26 - 22
Á 0.34 - 0.5 mm²
AWG 22-20
0.1 mm
PVC / PE
1.2 - 2.0 mm
À 5.5 - 7.2 mm
(black)
Á 7 - 8.8 mm
(light grey)
- 25 °C / + 85 °C
7 - 8.8 mm
6.8 - 9.5 mm (black)
4.7 - 6 mm
9 - 12.5 mm
6 - 8 mm
(grey)
- 25 °C / + 85 °C
- 40 °C / + 85 °C
- 40 °C / + 85 °C
2.0 - 2.3 mm
4.5 - 5.4 mm
(transparent)
7 - 8.8 mm
(light grey)
- 40 °C / + 85 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C
- 5 °C … + 50 °C
IP 67
IP 67
IP 65 / IP 67
IP 65 / IP 67
IP 67
10
10
10
10
0.6 Nm / SW 17
0.6 Nm / SW 17
1.5 Nm / SW 22
0.6 Nm / SW 17
7/8“
M12L, 5 poles
0.34 - 0.5 mm²
AWG 22 - 20
0.6 Nm / SW 17
1 = wire gauge 0.25 mm²
2 = wire gauge 0.34 mm²
Rated current [A]
Rated current [A]
1 = wire gauge 0.75 mm² / 1.5 mm²
0.25 - 0.34 mm²
AWG 24 - 22
0.34 - 0.5 mm²
AWG 22 - 20
0.1 mm
PVC
1.2 - 2.0 mm
Ambient temperature [oC]
M12, Crimp
1 = wire gauge 0.34 mm² /
0.5 mm²
Ambient temperature [oC]
M12L, 5 poles
1 = wire gauge 0.34 mm²
2 = wire gauge 0.5 mm²
Rated current [A]
Rated current [A]
HARAX
Ambient temperature
[oC]
Ambient temperature
[oC]
50
.
03
HARAX ® Circular connector
Assembly manual HARAX®
1.
1. strip cable
2. assemble HARAX ® elements
3. cut off cable ends
4. screw the connector
Nut
2.
Strain relief
Insert
3.
4.
Screw the nut onto the insert until a stop is
noticeable.
Note!
For reconnection cut off the used cable ends
and repeat steps 1 to 4.
Assembly manual HARAX ® shielded
1.
1. strip cable
2. assemble HARAX ® elements
twist screening braid ans push it into the
sealing slot
2.
3. Slide ring over the sealing cut off cable
ends and the screening braid
4. screw the connector
Nut
HARAX
3.
Strain relief
Insert
50
.
04
4.
Note!
For reconnection cut off the used cable ends
and repeat steps 1 to 4.
HARAX ® Circular connector
Identification
Part No.
Male
Female
Drawing
Dimensions in mm
HARAX ® M8-S
straight version, 3 poles
straight version, 4 poles
straight version, 3 poles
for 0.08 - 0.14 mm²
21 02 151 1305
21 02 151 1405
21 02 159 1305
21 02 151 2305
21 02 151 2405
straight version, 3 poles
straight version, 4 poles
View mating side:
3 poles, male version
View mating side:
4 poles, male version
HARAX ® M12-S
straight version, 4 poles
X = View
mating side
21 03 111 1405
21 03 111 2405
HARAX ® M12
angled version, 4 poles
X = View
mating side
View mating side:
21 01 140 5081
HARAX
angled version, 4 poles
21 01 140 5091
50
.
05
Stock items in bold type
Han02_Kap50_AT .indd 5
08 .12 .2008 12:40:33
HARAX ® Circular connector
Part No.
Identification
Male
Female
Drawing
Dimensions in mm
HARAX ® M12-L
3 poles, A-coded,
with pre-leading contact
3 poles, A-coded
4 poles, A-coded
21 03 212 1400
21 03 212 1306
21 03 212 1305
F
3 poles, A-coded,
with pre-leading contact
3 poles, A-coded
4 poles, A-coded
5 poles, A-coded,
0.25 - 0.34 mm², AWG 24 - 22
Cable diameter: 4.7 - 6 mm
M
21 03 212 2400
21 03 212 2306
21 03 212 2305
21 03 271 1505
View mating side, male version: HARAX ® M12-L
3 poles with
pre-leading
contact
3 poles
4 poles
21 03 271 2505
M
5 poles, A-coded,
0.34 - 0.5 mm², AWG 22 - 20
Cable diameter: 6 - 8 mm
21 03 272 1505
21 03 272 2505
F
Han® M12 panel feed-through
Male, A-coded,
50 cm conductors,
0.5 mm², 5 poles
21 03 311 1501
HARAX
50
.
06
Female, A-coded,
50 cm conductors,
0.5 mm², 5 poles
21 03 311 2501
Stock items in bold type
Han02_Kap50_AT .indd 6
08 .12 .2008 12:40:39
HARAX ® Circular connector
Part No.
Identification
Male
Female
HARAX ® M12-L, screened version
2 poles, B-coded
2 poles + shielding, B-coded
4 poles, D-coded,
0.14 - 0.34 mm², AWG 26-22
0.34 - 0.5 mm², AWG 22-20
4 poles, A-coded
Dimensions in mm
View mating side, male version:
HARAX ® M12-L, screened version
21 03 241 1301
21 03 241 1300
2 poles
21 03 241 1301
B-coded
21 03 281 1405
21 03 282 1405
21 03 221 1405
21 03 241 2301
21 03 241 2300
2-poles, B-coded
2 poles + shielding, B-coded
4 poles, D-coded,
0.14 - 0.34 mm², AWG 26-22
0.34 - 0.5 mm², AWG 22-20
4 poles, A-coded
Identification
Drawing
3 poles
PROFIBUS
B-coded
2 poles
21 03 241 2301
B-coded
4 poles
Ethernet
D-coded
4 poles
A-coded
21 03 281 2405
21 03 282 2405
21 03 221 2405
Part No.
Drawing
Dimensions in mm
Han® M12-RJ45
panel feed-through
4 poles,
D-coded,
angled
21 03 381 4400
Han® M12-RJ45
panel feed-through
4 poles,
D-coded,
straight
21 03 381 2400
HARAX
Han® M12
Gender Changer
4 poles, D-coded
21 03 381 6405
50
.
07
Stock items in bold type
Han® M12 panel feed-through
Identification
Part No.
Drawing
Dimensions in mm
Drawing
Dimensions in mm
Han® M12 panel feed-through
Female, D-coded,
50 cm conductors, AWG 22,
4 poles
21 03 371 2403
Male, D-coded,
50 cm conductors, AWG 22,
4 poles
21 03 371 1403
Han® M12 panel feed-through
Female, A-coded,
50 cm conductors, 0.5 mm²
Male, A-coded,
50 cm conductors, 0.5 mm²
Identification
21 03 311 2400
21 03 311 1402
Part No.
HARAX® panel feed-through
Female, A-coded
0.14 - 0.34 mm², AWG 26 - 22
5.5 - 7.2 mm
21 03 321 2425
Male, A-coded
0.14 - 0.34 mm², AWG 26 - 22
5.5 - 7.2 mm
21 03 321 1425
Han® M12 panel feed-through Crimp
HARAX
Female, A-coded
4.5 - 5.4 / 7 - 8.8 mm
50
.
08
21 03 822 2425
Male, A-coded
4.5 - 5.4 / 7 - 8.8 mm
21 03 822 1425
Stock items in bold type
Han02_Kap50_AT .indd 8
08 .12 .2008 12:40:56
Han® M12 panel feed-through
Identification
Part No.
Drawing
Dimensions in mm
Han® M12 panel feed-through
for outer termination
Female, D-coded, screened version,
360 mm cable1), AWG 26, 4 poles
21 03 383 6407
Han® M12 panel feed-through
for inner termination
Female, D-coded, screened version,
700 mm cable1), AWG 26, 4 poles
21 03 383 6405
Han® M12 panel feed-through
with RJ45
Female, D-coded, screened version,
48 mm cable1), AWG 26, 4 poles
21 03 683 6401
HARAX® panel feed-through
Female,
D-coded
0.14 - 0.34 mm²,
AWG 26 - 22
5.5 - 7.2 mm
21 03 381 2425
HARAX
Han® M12 panel feed-through
Crimp
Female,
D-coded
4.5 - 5.4 / 7 - 8.8 mm
21 03 882 2425
50
.
09
1) Other
length on request
Stock items in bold type
Han® M12 pcb adapter
Technical characteristics: Han® M12 pcb
Degree of protection
Rated current
Rated voltage
mating cycles
Limiting temperatures
Temperature during connection
IP 20
max. 4 A (dependent on pcb layout)
50 V
max. 100
- 25 °C / + 85 °C
- 5 °C / + 50 °C
Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts
including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded
contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum
temperature.
Control and test procedures according to DIN IEC 60 512-5.
wire gauge 0.75 mm²
Rated current [A]
M12, A-Kodierung, straight, female, 4 poles
wire gauge 0.5 mm²
Rated current [A]
M12, A-Kodierung, straight, male, 4 poles
Ambient temperature [°C]
Ambient temperature [°C]
wire gauge 0.5 mm²
Rated current [A]
M12, A-Kodierung, straight, male, 5 poles
wire gauge 0.5 mm²
Rated current [A]
M12, A-Kodierung, straight, female, 5 poles
Ambient temperature [°C]
50
.
10
M12, D-Kodierung, gewinkelt, female, 4 poles
wire gauge 0.5 mm²
wire gauge AWG 22
Rated current [A]
M12, D-Kodierung, straight, female, 4 poles
Rated current [A]
HARAX
Ambient temperature [°C]
Ambient temperature [°C]
Ambient temperature [°C]
Han® M12 pcb adapter
Identification
Part No.
Drawing
Dimensions in mm
Han® M12
Female, D-coded,
straight, 4 poles
21 03 371 2415
21 03 381 6410
Han® M12
Male, D-coded,
straight, 4 poles
21 03 371 1400
Han® M12
Female, D-coded,
angled, 4 poles
without fixing hole
21 03 381 4410
HARAX
with fixing hole
21 03 381 4412
50
.
11
Stock items in bold type
Han® M12 pcb adapter
Identification
Part No.
Drawing
Dimensions in mm
Han® M12
Female, A-coded,
straight
4 poles
21 03 321 6410
5 poles
21 03 321 6510
4 poles
21 03 321 1410
5 poles
21 03 321 1510
Han® M12
Male, A-coded,
straight
HARAX
50
.
12
Stock items in bold type
Notes
HARAX
50
.
13
microFX®
*HQHUDO'HVFULSWLRQ
l
l
Fibre optic data transmission system
for industrial applications
Optical transceiver for 1300 nm
l
Passive interface as coupling unit
and panel feed-through
l
Based on M12 hoods and housings
in accordance with IEC 61 076-2-101
l
Suitable for multimode glass fibre
l
2 supplementary electrical contacts
l
Degree of protection: IP 65 / IP 67
l
Wide temperature range
of -40 °C up to +85 °C
l
Minimum insertion loss: < 0.3 dB
,GHQWL¿FDWLRQ
3DUW1R
7UDQVFHLYHU
7HFKQLFDOFKDUDFWHULVWLFV
Mechanical Features
6WRUDJHWHPSHUDWXUH
&&
:RUNLQJWHPSHUDWXUH
&&
'HJUHHRISURWHFWLRQ
,3
7LJKWHQLQJWRUTXH
1FP
Electrical Data
5DWHGYROWDJHRIHOHFWULFDOFRQWDFWV
9'&
5DWHGFXUUHQW
$PD[
Optical Data Transceiver for Multimode
&HQWHUZDYHOHQJWKȜ&
QPXSWRQP
2XWSXWRSWLFDOSRZHUPD[30
G%P
,QSXWRSWLFDOSRZHUPLQ36$7
G%P
'DWDWUDQVPLVVLRQUDWH
0ELWV
LQDFFRUGDQFH
ZLWK)DVW(WKHUQHW
%DVH);,((X
'UDZLQJ
'LPHQVLRQVLQPP
9LHZPDWLQJVLGH
IRUPXOWLPRGH
ZLWKJODVV¿EUHV
QP
3DQHOFXWRXW
PP
HARAX
50
.
14
Contact Function Description
9&&5; 5HFHLYHUVXSSO\YROWDJH9
2
5;
5HFHLYHUGDWDRXWSXWQRQLQYHUWHG3(&/
RX5HFHLYHUGDWDRXWSXWLQYHUWHG3(&/
*1' *URXQG5HFHLYHU
6'
6LJQDO'HIHFW3(&/
566, 5HFHLYHUVLJQDOVWUHQJWKLQGLFDWRURXWSXWDQDORJYROWDJH
5HV
5HVHUYHGIRUIXWXUHXVH
6&/
9
6'$
7;',6
*1' *URXQG7UDQVPLWWHU
TX7UDQVPLWWHUGDWDLQSXWLQYHUWHG3(&/
7;
7UDQVPLWWHUGDWDLQSXWQRQLQYHUWHG3(&/
9&&7; 7UDQVPLWWHUVXSSO\YROWDJH9
Stock items in bold type
microFX®
,GHQWL¿FDWLRQ
3DUW1R
'UDZLQJ
'LPHQVLRQVLQPP
&RQQHFWRU
9LHZ
PDWLQJVLGH
RUGHUFRQWDFWVVHSDUDWHO\
2SWLFDO&RQWDFWV
IRU*,¿EUHV
P
(OHFWULFDO&RQWDFWV
PP²ZLUHJDXJH
3DQHOIHHGWKURXJK
9LHZPDWLQJVLGH
&RXSOLQJXQLW
9LHZPDWLQJVLGH
HARAX
&RUGVHW
/HQJWKP
P
P
P
50
.
15
Stock items in bold type
Han® 7/8“ Circular connector
Identification
Part No.
Drawing
Dimensions in mm
HARAX ® 7/8“ Male
21 04 116 1505
HARAX ® 7/8“ Female
21 04 116 2505
Han® 7/8“ panel feed-through
30 cm conductors, 0.75 mm²
Male
21 04 316 1505
Female
21 04 316 2505
HARAX
30 cm conductors, 0.75 mm²
50
.
16
Stock items in bold type
Han® M12 Crimp
Identification
Part No.
Drawing
Dimensions in mm
Han® M12 Crimp
Complete length when assembled app. 41.5 mm
Male, D-coded
4.5 - 5.4 mm / 7 - 8.8 mm
21 03 882 1405
SW 17
Complete length when assembled app. 41.5 mm
Male, A-coded
4.5 - 5.4 mm / 7 - 8.8 mm
SW 13
21 03 812 1405
SW 17
Complete length when assembled app. 38 mm
Female, A-coded
4.5 - 5.4 mm / 7 - 8.8 mm
SW 13
21 03 812 2405
SW 17
SW 13
Order crimp contacts separately
Crimping tool
09 99 000 0501
Locator
61 03 600 0023
Single contacts
turned male contacts*
AWG 22-20 / 0.33-0.52
AWG 26-22 / 0.13-0.33
61 03 000 0073
61 03 000 0094
AWG 22-20
AWG 26-22
turned female contacts*
AWG 22-20 / 0.33-0.52
AWG 26-22 / 0.13-0.33
a
8.10
8.10
b
4.0
4.0
c
14.8
14.8
d
1.12
0.90
e
1.66
1.66
f
14.4
14.4
HARAX
61 03 000 0074
61 03 000 0096
50
.
17
* Performance level 1 as per CECC 75301-802, 500 mating cycles,
10 days 4 mixed gas test – IEC 60512
Stock items in bold type
®
HARAX Pg 9 panel feed-through
Features
Technical characteristics
O
The faston blade was chosen
acc. to DIN 46 330 - A 2.8
Rated voltage
32 V
Rated current
(see current carrying capacity)
4A
Each type is delivered with a termination
element consisting of a nut, a seal an a splice
ring
Wire gauge
0.25 - 0.5 mm²
24/7 AWG - 22 AWG
Diameter of individual strands
0.1 mm
Conductor insulation material
PVC
Conductor diameter
1.2 - 1.6 mm
Cable diameter
4.0 - 5.1 mm
Working temperature
- 25 oC … + 85 oC
Temperature during connection
- 5 oC … + 50 oC
Degree of protection
IP 67
Termination cycles with
the same cross section
10
O
O
O
O
Splice ring with Pg 9
For assembly in openings without threads
a Pg 9 locknut is available
Diameter of the mounting cutout:
d = 15.5 mm
Current carrying capacity
Assembly manual
The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The
current capacity-curve is valid for continuous, not interrupted
current-loaded contacts of connectors when simultaneous power
on all contacts is given, without exceeding the maximum temperature.
1.
Control and test procedures according to DIN IEC 60 512-3.
Strip cable jecket
Pg 9, 3 contacts
1 = wire gauge
3 x 0.25 mm²
Assemble
HARAX®
elements
a Nut
b Strain relief
c Insert
2 = wire gauge
3 x 0.5 mm²
Rated current [A]
2.
3.
Ambient temperature [oC]
Put seal and splice ring together
Cut off cable ends
HARAX
4.
1 = wire gauge
4 x 0.25 mm²
2 = wire gauge
4 x 0.5 mm²
50
.
18
Twist the nut onto the
insert until a stop
is noticeable
Rated current [A]
Pg 9, 4 contacts
Ambient temperature [oC]
®
HARAX Pg 9 panel feed-through
Identification
Part No.
Drawing
Dimensions in mm
HARAX ® Pg 9 panel feed-through
View:
Termination side
3 contacts, with pre-assembled
0.5 m / 0.5 mm² pigtail cable
21 01 130 4241
HARAX ® Pg 9 panel feed-through
View:
Termination side
4 contacts, with pre-assembled
0.5 m / 0.5 mm² pigtail cable
21 01 140 4341
HARAX ® Pg 9 panel feed-through
Faston blade termination
acc. to DIN 46 330-A 2,8
View:
Termination side
3 contacts
with faston blades
21 01 130 4011
Termination element M12 HARAX ® 3 contacts
Screw cap, splice ring, seal
21 01 010 0001
HARAX
Termination element M12 HARAX ® 4 contacts
Screw cap, splice ring, seal
21 01 010 0006
50
.
19
Stock items in bold type
HARAX ® Pg 13.5 / M20 panel feed-through
Technical characteristics
Construction type
Rated voltage
acc. to UL / CSA
Rated current
(see current carrying
capacity)
Testing voltage
Conductor cross section
Diameter of
individual strands
Outer cable diameter
Termination cycles with
the same cross section
Limiting temperature
Temperature during
connection
Degree of protection
Conductor insulation material
Max. tightening torque
Pg 13,5
3 poles
250 V 4 kV 3
with faston
terminals with
insulation cap
600 V
16 A
Pg 13,5 / M20
4 poles
230/400 V 4 kV 3
600 V
16 A
4 kV (1.2 / 50)
0.75 - 1.5 mm²
4 kV (1.2 / 50)
0.75 - 1.5 mm²
0.2 mm
6.0 - 9.0 mm
0.2 mm
6.0 - 9.0 mm
10
- 25 / + 85 oC
10
- 25 / + 85 oC
- 5 … + 50 oC
IP 67
PVC
8 Nm
- 5 … + 50 oC
IP 67
PVC
8 Nm
Current carrying capacity
1 = wire gauge
0.75 mm²
2 = wire gauge
1.5 mm²
Rated current [A]
Approval
Pg 13,5
3 contacts
IEC 60 352-4
DIN 61 984
, VDE
Ambient temperature [oC]
Pg 13,5 / M20
4 contacts
1 = wire gauge
0.75 mm²
2 = wire gauge
1.5 mm²
Rated current [A]
Specifications
The current carrying capacity is limited by maximum temperature
of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted currentloaded contacts of connectors when simultaneous power on all
contacts is given, without exceeding the maximum temperature.
Control and test procedures according to DIN IEC 60 512-3.
Ambient temperature [oC]
Assembly manual
1.
2.
3.
Nut
Strain relief
Insert
HARAX ® Pg 13.5 – 3 contacts – is supplied with either faston blades or solder
terminals.
HARAX ® Pg 13.5 / M20 – 4 contacts – is supplied only with solder termination.
HARAX
4.
50
.
20
Connection and disconnection of the cable must only be performed by suitably
qualified persons when supply is isolated.
The nut must be tightened completely down so that the notches engage on the
contact carrier.
The opening of the gland always requires a wrench.
Note: For reconnection cut off the used cable ends and repeat steps 1 to 4.
HARAX ® Pg 13.5 / M20 panel feed-through
Identification
Part No.
HARAX ® Pg 13.5 / 3 contacts
with faston blades
Drawing
Dimensions in mm
View:
Mating side
21 01 130 1013
HARAX ® Pg 13.5 / 3 contacts
with solder termination
21 01 130 1023
HARAX ® Pg 13.5 / 3 contacts
with pre-assembled pigtail cable. I = 500 mm, 1.5 mm²
21 01 130 1223
HARAX ® Pg 13.5 / 2 + PE
with faston blades
View:
Mating side
21 01 130 3013
HARAX ® Pg 13.5 / 2 + PE
with solder termination
21 01 130 3023
HARAX ® Pg 13.5 / 2 + PE
with pre-assembled pigtail cable, I = 500 mm, 1.5 mm²
21 01 130 3233
HARAX ® Pg 13.5 / 4 contacts
with solder termination
21 01 140 1023
View:
Mating side
HARAX ® Pg 13.5 / 3 + PE
with solder termination
21 01 140 3023
HARAX ® Pg 13.5 / 4 contacts
with pre-assembled strand, I = 500 mm, 1.5 mm²
21 01 140 1323
HARAX ® Pg 13.5 / 3 + PE
with pre-assembled strand, l = 500 mm, 1.5 mm²
21 01 140 3333
HARAX ® M20 / 4 contacts
with solder termination
21 01 141 1023
View:
Mating side
HARAX ® M20 / 3 + PE
with solder termination
HARAX
21 01 141 3023
HARAX ® M20 / 4 contacts
with pre-assembled strand, l = 500 mm, 1.5 mm²
21 01 141 1323
HARAX ® M20 / 3 + PE
with pre-assembled strand, l = 500 mm, 1.5 mm²
Other length on request
50
.
21
21 01 141 3333
Stock items in bold type
Notes
HARAX
50
.
22
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, A-coded
Han® M8 Circular connector
Technical characteristics
Han® M12 Circular connector, without PE
Rated voltage
max. 250 V AC/DC, max. 30 V DC (with LED)
Rated current/contact
max. 4 A
Locking
Screw locking M12x1, self securing
Recommended torque
0.6 Nm
Temperature range
(dependent on connected conductor)
- 25 °C … +85 °C
Degree of protection
IP 67
Number of wires / wire gauge
4 x 0.34 mm²
Conductor insulation
PP (br, ws, bl, sw)
Arrangement of insulated strands
42 x 0.1 mm
Sheath
PUR (UL, CSA)
Outer diameter
appr. 4.7 mm
Bending radius
10 x outer diameter
Temperature range (working and storage)
-25 °C … + 80 °C
Han® M8 Circular connector, without PE
Rated voltage
max. 60 V AC/DC
Rated current/contact
max. 4 A
Locking
Screw locking M8x1, self securing
Recommended torque
0.4 Nm
Temperature range
(dependent on connected conductor)
-25 °C … +85 °C
Degree of protection
IP 67
Number of wires / wire gauge
3 x 0.25 mm²
Conductor insulation
PP (br, bl, sw)
Arrangement of insulated strands
32 x 0.1 mm
Sheath
PUR (UL, CSA)
Outer diameter
appr. 4.1 mm
Bending radius
10 x outer diameter
Temperature range (working and storage)
-5 °C … + 80 °C
HARAX
50
.
23
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, A-coded
Identification
Part No.
Drawing
Dimensions in mm
Han® M12 Circular connector
Female straight, Male straight
Cable sleeve
Cable imprint
View mating side
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 03 415 2401
21 03 415 2402
21 03 415 2403
21 03 415 2404
21 03 415 2405
Schematic diagram
Han® M12 Circular connector
Female angled, Male straight
View mating side
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 03 415 5401
21 03 415 5402
21 03 415 5403
21 03 415 5404
21 03 415 5405
Schematic diagram
Han® M12 Circular connector
Female angled, with LED,
Male straight
View mating side
HARAX
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 03 415 7401
21 03 415 7402
21 03 415 7403
21 03 415 7404
21 03 415 7405
Schematic diagram
50
.
24
Stock items in bold type
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, A-coded
Identification
Part No.
Drawing
Dimensions in mm
Han® M12 Circular connector
Female angled
pre-assembled on one end
Schematic diagram
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
View
mating side
21 03 515 4401
21 03 515 4402
21 03 515 4403
21 03 515 4404
21 03 515 4405
HARAX
X® M12 cable-Set
Delivery range: Han® M12 connector
with individually adaptable cable and
HARAX
X® M12-S
Length:
1,5 m
3,0 m
5,0 m
7,5 m
10,0 m
21 83 515 4401
21 83 515 4402
21 83 515 4403
21 83 515 4404
21 83 515 4405
HARAX
X® M12-S (21 03 111 1405)
View
mating side
Han® M12 Circular connector
Female angled, with LED
pre-assembled on one end
Schematic diagram
Length:
1,5 m
3,0 m
5,0 m
7,5 m
10,0 m
View
mating side
21 03 515 7401
21 03 515 7402
21 03 515 7403
21 03 515 7404
21 03 515 7405
HARAX
X® M12 cable-Set
Delivery range: Han® M12 connector
with individually adaptable cable and
HARAX
X® M12-S
Length:
1,5 m
3,0 m
5,0 m
7,5 m
10,0 m
HARAX
21 83 515 7401
21 83 515 7402
21 83 515 7403
21 83 515 7404
21 83 515 7405
HARAX
X® M12-S (21 03 111 1405)
View
mating side
Stock items in bold type
50
.
25
Han® M8 Circular connector
System cables with
Han® M8 Circular connector
Identification
Part No.
Drawing
Dimensions in mm
Han® M8 Circular connector
Female angled, Male straight
Cable sleeve
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
Cable imprint
View mating side
21 02 454 5301
21 02 454 5302
21 02 454 5303
21 02 454 5304
21 02 454 5305
Schematic diagram
Han® M8 Circular connector
Female angled, with LED
Male straight
Cable sleeve
Cable imprint
View mating side
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 02 454 7301
21 02 454 7302
21 02 454 7303
21 02 454 7304
21 02 454 7305
Schematic diagram
HARAX
50
.
26
Stock items in bold type
Han® M8 Circular connector
System cables with
Han® M8 Circular connector
Identification
Part No.
Drawing
Dimensions in mm
Han® M8 Circular connector
Female angled
pre-assembled on one end
Schematic diagram
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 02 554 4301
21 02 554 4302
21 02 554 4303
21 02 554 4304
21 02 554 4305
View mating
side
HARAX
X® M8 cable-Set
Delivery range: Han® M8 connector
with individually adaptable cable and
HARAX
X® M8-S
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 82 554 4301
21 82 554 4302
21 82 554 4303
21 82 554 4304
21 82 554 4305
HARAX
X® M8-S (21 02 151 1305)
View mating
side
Han® M8 Circular connector
Female angled, with LED
pre-assembled on one end
Schematic diagram
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 02 554 7301
21 02 554 7302
21 02 554 7303
21 02 554 7304
21 02 554 7305
View mating
side
HARAX
X® M8 cable-Set
Delivery range: Han® M8 connector
with individually adaptable cable and
HARAX
X® M8-S
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
HARAX
21 82 554 7301
21 82 554 7302
21 82 554 7303
21 82 554 7304
21 82 554 7305
HARAX
X® M8-S (21 02 151 1305)
View mating
side
Stock items in bold type
50
.
27
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, B-coded
Technical characteristics
Rated voltage
max. 125 V AC/ DC
Rated current/contact
max. 4 A
Locking
Screw locking M12 x 1 mm, self securing
Recommended torque
0.6 Nm
Temperature range (male) °C
-25 °C … +85 °C
(dependent on connected conductor)
Degree of protection
IP 67
Number of wires / wire gauge
4 x 0.64 mm²
Conductor insulation
PUR (rt, gn)
Arrangement of insulated strands
19 x 0.13 mm
Sheath
PUR (UL/CSA)
Outer diameter
appr. 7.8 mm
Bending radius
65 x outer diameter
Temperature range °C (applicate with fixed cable)
-30 °C … + 80 °C
Identification
Part No.
Drawing
Han® M12 Circular connector,
Male, straight
pre-assembled on one end,
useable as trailing cable
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 03 549 1301
21 03 549 1302
21 03 549 1303
21 03 549 1304
21 03 549 1305
Schematic
diagram
2
4
JUHHQ
grün
UHG
rot
VKLHOGLQJ
Schirm
Han® M12 Circular connector,
Male, angled
HARAX
pre-assembled on one end,
useable as trailing cable
Length:
50
.
28
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 03 549 3301
21 03 549 3302
21 03 549 3303
21 03 549 3304
21 03 549 3305
Schematic
diagram
2
4
JUHHQ
grün
UHG
rot
VKLHOGLQJ
Schirm
Stock items in bold type
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, B-coded
Identification
Part No.
Drawing
Han® M12 Circular connector,
Female, straight
pre-assembled on one end,
useable as trailing cable
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 03 549 2301
21 03 549 2302
21 03 549 2303
21 03 549 2304
21 03 549 2305
grün
JUHHQ
rot
UHG
2
Schematic
diagram
4
VKLHOGLQJ
Schirm
Han® M12 Circular connector,
Female, angled
pre-assembled on one end,
useable as trailing cable
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 03 549 4301
21 03 549 4302
21 03 549 4303
21 03 549 4304
21 03 549 4305
grün
JUHHQ
rot
UHG
2
Schematic
diagram
4
VKLHOGLQJ
Schirm
Han® M12 Circular connector,
Male, straight
Female, straight
pre-assembled on one end,
useable as trailing cable
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 03 449 4301
21 03 449 4302
21 03 449 4303
21 03 449 4304
21 03 449 4305
Schematic
diagram
2
2
4
4
VKLHOGLQJ
Schirm
Han® M12 Circular connector,
Male, angled
Female, angled
HARAX
pre-assembled on one end,
useable as trailing cable
Length:
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 03 449 6301
21 03 449 6302
21 03 449 6303
21 03 449 6304
21 03 449 6305
Schematic
diagram
2
2
4
4
50
.
29
VKLHOGLQJ
Schirm
Stock items in bold type
Han® M12 Accessories, B-coded
Identification
Part No.
Technical characteristics
Han® M12-male
moving load
B-coded
21 03 030 1300
Han® M12-male/female
panel feed-through
B-coded
21 03 330 1300
Han® M12-panel feed-through
Male, B-coded, 20 cm conductor
Rated voltage
24 V AC/DC
Voltage/contact
4A
Thread
M16 x 1.5
Degree of protection
IP 67 in locked position
(EN 60529)
Temperature range
-25 °C … + 85 °C
Rated voltage
250 V AC/DC
Voltage/contact
max. 4A
Termination
solder, with pigtails (TPE
insulation) assembled
21 03 339 1301
Conductor cross section 0.25 mm²
Han® M12-panel feed-through
Female, B-coded, 20 cm conductor
Degree of protection
IP 67 in locked position
(EN 60529)
Temperature range
-25 °C … + 85 °C
Rated voltage
250 V AC/DC
Voltage/contact
max. 4A
Termination
solder, with pigtails (TPE
insulation) assembled
21 03 339 2301
Conductor cross section 0.25 mm²
Degree of protection
IP 67 in locked position
(EN 60529)
Temperature range
-25 °C … + 85 °C
PROFIBUS-cable
100 m raw, PUR cable,
useable as trailing cable
21 01 000 0021
HARAX
Han® M12
dynamometric screwdriver
50
.
30
Han® M8
dynamometric screwdriver
SW 9
09 99 000 0380
SW 13
SW 17
09 99 000 0382
09 99 000 0384
Stock items in bold type
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, D-coded
Technical characteristics
Han® M12 Circular connector – AWG 22/7
Rated voltage
max. 50 V AC/DC
Rated current/contact
max. 4 A
Locking
Screw locking M12x1, self securing
Recommended torque
0.6 Nm
Temperature range
- 20 °C … +60 °C
Degree of protection
IP 67
Number of wires / wire gauge
2 x 2 x AWG 22/7
Conductor insulation
PE (yellow, orange, white, blue) acc. to PROFInet®
Arrangement of insulated strands
7 x 0.25 mm
Sheath
PUR (UL, CSA)
Outer diameter
appr. 6.5 mm
Bending radius
10 x outer diameter
Temperature range
-20 °C … + 60 °C
Han® M12 Circular connector – AWG 26
Rated voltage
max. 50V AC/DC
Rated current/contact
max. 2 A
Locking
Screw locking M12x1, self securing
Recommended torque
0.6 Nm
Temperature range
- 5 °C … +60 °C
Degree of protection
IP 67
Number of wires / wire gauge
2 x 2 x AWG 26
Conductor insulation
PE (white/orange, orange, white/green, green)
acc. to EIA/ TIA 568B
Arrangement of insulated strands
7 x 0.16 mm
Sheath
PUR (UL, CSA)
Outer diameter
appr. 5.6 mm
Bending radius
10 x outer diameter
Temperature range
-5 °C … + 60 °C
HARAX
50
.
31
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, D-coded
Identification
Part No.
Pre-assembled and
tested system cables
for structured cabling of industrial
Ethernet networks, based on Han®
M12 Circular connectors, D-coded
Drawing
Dimensions in mm
Cable type:
Shielded Twisted Pair
Standard Cable
Mating interface:
M12 D-coded
acc. to IEC 61 076-2-101
Transmission performance
acc. to ISO/IEC 11801:2002:
Class D, 100% tested
Degree of protection
IP 65 / IP 67 (when mated)
Pin assignment
2 x Han® M12
Circular connector,
D-coded,
straight
Length: 1 m
3m
5m
10 m
15 m
25 m
40 m
21 03 483 1401
21 03 483 1403
21 03 483 1405
21 03 483 1410
21 03 483 1415
21 03 483 1425
21 03 483 1440
Conductor
colour
EIA/TIA
568B
Contact
assignment
Signal
Function
Conductor
colour
PROFInet®
TD+
Transmission Data+
Yellow
White/
Orange
1
TD-
Transmission Data-
Orange
Orange
3
RD+
Receiver Data+
White
White/Green
2
RD-
Receiver Data-
Blue
Green
4
cable: AWG 26 / 0.14 mm²
other length on request
HARAX
50
.
32
2 x Han® M12
Circular connector,
D-coded,
straight
Length: 1 m
3m
5m
10 m
15 m
25 m
40 m
21 03 485 1401
21 03 485 1403
21 03 485 1405
21 03 485 1410
21 03 485 1415
21 03 485 1425
21 03 485 1440
cable: AWG 22 / 0.34 mm²
other length on request
Stock items in bold type
Han® M12 Circular connector
System cables with
Han® M12 Circular connector, D-coded
Identification
Part No.
Pre-assembled and
tested system cables
for structured cabling of industrial
Ethernet networks, based on Han®
M12 Circular connectors, D-coded
Drawing
Dimensions in mm
Cable type:
Shielded Twisted Pair
Standard Cable
Mating interface:
M12 D-coded
acc. to IEC 61 076-2-101
Transmission performance
acc. to ISO/IEC 11801:2002:
Class D, 100% tested
Degree of protection
IP 65 / IP 67 (when mated)
Pin assignment
1 x Han® M12
Circular connector,
D-coded,
straight
Length: 1 m
3m
5m
10 m
25 m
40 m
21 03 583 1401
21 03 583 1403
21 03 583 1405
21 03 583 1410
21 03 583 1425
21 03 583 1440
Conductor
colour
EIA/TIA
568B
Contact
assignment
Signal
Function
Conductor
colour
PROFInet®
TD+
Transmission Data+
Yellow
White/
Orange
1
TD-
Transmission Data-
Orange
Orange
3
RD+
Receiver Data+
White
White/Green
2
RD-
Receiver Data-
Blue
Green
4
cable: AWG 26 / 0.14 mm²
other length on request
1 x Han® M12
Circular connector,
D-coded,
straight
Length: 1 m
3m
5m
10 m
25 m
40 m
21 03 585 1401
21 03 585 1403
21 03 585 1405
21 03 585 1410
21 03 585 1425
21 03 585 1440
cable: AWG 22 / 0.34 mm²
HARAX
50
.
33
other length on request
Stock items in bold type
Han® M12 Circular connector
Identification
Part No.
Drawing
Dimensions in mm
1 x Han® M12
Circular connector, straight
pre-assembled on one end,
8 poles
Length:
1.0 m
21 03 514 1801
3.0 m
21 03 514 1803
5.0 m
21 03 514 1805
Han® M12 Circular connector
with IDC termination technology,
8 poles
21 03 121 1801
Han® M12 pcb
8 poles
21 03 311 2801
HARAX
50
.
34
Stock items in bold type
Circular connector 7/8’’
Overmolded cordsets 7/8’’
Technical characteristics
Degree of protection
IP 67
Temperature range
applies to moved cable
cables permanently installed
-20 °C … +80 °C
-50 °C … +80 °C
Rated current
max. 8 A every contact (+40 °C)
Rated voltage
230 / 400 V
Rated impulse voltage
3 kV
Pollution degree
3
Material group
Category I acc. to IEC 60 664-1
Cable data
Jacket material
PUR
Jacket colour
grey
Wire isolation
TPM
Wire colours
brown, white, blue, black, green/yellow
Wire gauge
5 x 1.5 mm²
Standards
UL / CSA
HARAX
50
.
35
Circular connector 7/8’’
Overmolded cordsets 7/8’’
Identification
Part No.
Drawing
Dimensions in mm
Overmolded cordsets 7/8’’
Female straight
5 pin
Length:
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 04 516 2501
21 04 516 2502
21 04 516 2503
21 04 516 2504
21 04 516 2505
1.5 m
3.0 m
5.0 m
7.5 m
10.0 m
21 04 516 4501
21 04 516 4502
21 04 516 4503
21 04 516 4504
21 04 516 4505
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 04 416 1501
21 04 416 1502
21 04 416 1503
21 04 416 1504
21 04 416 1505
0.3 m
0.6 m
1.0 m
1.5 m
2.0 m
21 04 416 3501
21 04 416 3502
21 04 416 3503
21 04 416 3504
21 04 416 3505
Schematic diagram
View mating
side
Overmolded cordsets 7/8’’
Female angled
5 pin
Length:
Schematic diagram
View mating
side
Overmolded cordsets 7/8’’
Male-Female straight
5 pin
Length:
Schematic diagram
View mating side
Schematic diagram
View mating side
Overmolded cordsets 7/8’’
Male-Female angled
5 pin
Length:
HARAX
50
.
36
Stock items in bold type
Han02_Kap50_AT .indd 36
08 .12 .2008 12:42:28
Accessories
Identification
Part No.
Drawing
Dimensions in mm
Seal M12
2.9 - 4.0 mm
4 - 5.1 mm
21 01 010 2011
21 01 010 2001
Seal M12-L
3 poles:
5.5 - 7.2 mm
4 + 5 poles: 6 - 8 mm
21 01 010 2003
21 01 010 2007
Seal M8
for 2.5 - 3.5 mm cable Ø
for 3.2 - 4.4 mm cable Ø
for 4.2 - 5.4 mm cable Ø
21 01 010 2008
21 01 010 2004
21 01 010 2005
Set of 3 seals for HARAX ® M8-S
for 2.5 - 3.2 mm cable Ø
for 3.2 - 4.0 mm cable Ø
for 4.0 - 5.1 mm cable Ø
21 01 010 2013
Seal Pg 13.5 / M20
6 - 9 mm
21 01 010 2002
HARAX
Cap M12
21 01 000 0003
50
.
37
Stock items in bold type
Accessories
Identification
Part No.
Drawing
Dimensions in mm
Lock nut Pg 9
nickel plated
21 01 000 0008
Lock nut M16
nickel plated
21 01 000 0010
Lock nut 7/8’’
nickel plated
21 01 000 0023
Lock nut Pg 13.5
nickel plated
21 01 000 0020
Lock nut Pg 13.5
21 01 000 0007
Lock nut M20
21 01 000 0009
HARAX
Socket wrench
21 01 000 0001
50
.
38
Stock items in bold type