0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
21 03 311 2400

21 03 311 2400

  • 厂商:

    HARTING(浩亭)

  • 封装:

  • 描述:

    HARTING - 21 03 311 2400 - Sensor Cable, HARAX, M12 Receptacle, Free End, 4 Positions, 500 mm, 19.6 ...

  • 数据手册
  • 价格&库存
21 03 311 2400 数据手册
HARAX ® Contents Page Technical characteristics circular connector with HARAX ® rapid termination 50.02 Circular connector M8/M12 with HARAX ® rapid termination . . . . . . . . . . . 50.05 Han® M12 panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.08 Han® M12 pcb adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.10 microFX® . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.12 Han ® 7/8’’ circular connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.16 Han® M12 circular connector with crimp termination . . . . . . . . . . . . . . . . . . 50.17 HARAX ® panel feed-through . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.18 Han® M8 and Han® M12 system cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.23 Circular connector 7/8“ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.35 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50.37 HARAX ® 7/8“ Han® M12-Crimp HARAX 50 . 01 ® HARAX Circular connector Technical characteristics Specifications Approval IEC 60 352-4 IEC 61 076-2-101 IEC 61 076-2-104 HARAX ® M8-S/ HARAX ® M8-S (0.08 mm²) M12-S 32 V 32 V HARAX ® M12 angled 32 V HARAX ® M12-L 3 poles, 4 poles 50 V HARAX ® M12-L screened version, A-coded 50 V 2A 4A 4A 6A 4A Conductor cross section 0.08 - 0.14 mm² AWG 28 - 26 0.14 - 0.34 mm² AWG 26 - 22 0.25 - 0.5 mm² AWG 24/7 - 20 0.34 - 0.75 mm² AWG 22 - 18 0.14 - 0.34 mm² AWG 26 - 22 Diameter of individual strands Conductor insulation material Conductor diameter • 0.05 mm PVC / PP / TPE 0.6 - 1.0 mm • 0.1 mm PVC / PP / TPE 1.0 - 1.6 mm M8-S: 2.5 - 5.1 mm 1.9 - 2.5 mm (transp.) M12-S: 2.5 - 3.5 mm (grey) 2.5 - 4.0 mm (transp.) 4.0 - 5.1 mm (black) - 25 °C / + 85 °C - 25 °C / + 85 °C • 0.1 mm PVC 1.2 - 1.6 mm • 0.1 mm PVC 1.6 - 2.0 mm • 0.1 mm PVC 1.2 - 1.6 mm 4 - 5.1 mm 3 poles: 5.5 - 7.2 mm 7 - 8.8 mm 4 poles: 6 - 8 mm - 25 °C / + 85 °C - 25 °C / + 85 °C - 25 °C / + 85 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C IP 67 IP 67 IP 67 IP 65 / IP 67 IP 67 10 10 10 10 10 0.4 Nm / SW 9 M8-S: 0.4 Nm / SW 9 0.6 Nm / SW 13 M12-S: 0.6 Nm / SW 13 0.6 Nm / SW 17 0.6 Nm / SW 17 Construction type Rated voltage Rated current (see current carrying capacity) Cable diameter Limiting temperatures Temperature during connection Degree of protection Termination cycles with the same cross section Recommended tightening torque / Hexagonal wrench Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. Control and test procedures according to DIN IEC 60 512-5. M8-S, 4 poles 1 = wire gauge 0.25 mm² M12-S, 4 poles 2 = wire gauge 0.34 mm² Rated current [A] wire gauge 1.4 mm² Rated current [A] M8-S, 3 poles Ambient temperature [oC] M12-L 3 poles, 4 poles 1 = wire gauge 0.34 mm² 2 = wire gauge 0.75 mm² Rated current [A] 50 . 02 M12, 4 poles, angled 1 = wire gauge 0.25 mm² 2 = wire gauge 0.5 mm² Rated current [A] HARAX Ambient temperature [oC] Ambient temperature [oC] Ambient temperature [oC] ® HARAX Circular connector Technical characteristics Specifications Approval IEC 60 352-4 IEC 61 076-2-101 IEC 61 076-2-104 Construction type Rated voltage Rated current (see current carrying capacity) Conductor cross section Diameter of individual strands Conductor insulation material Conductor diameter Cable diameter Limiting temperatures Temperature during connection Degree of protection Termination cycles with the same cross section Recommended tightening torque / Hexagonal wrench HARAX ® M12-L screened version Ethernet PROFIBUS 50 V 32 V 4A 4A 0.25 - 0.34 mm² AWG 24- 22 0.75 - 1.5 mm² AWG 18 - 16 • 0.1 mm PVC, Zell-PE 2 - 2.6 mm • 0.15 mm PVC, PP, TPE ”2.8 mm Han ® 7/8“ 230 V / 400 V HARAX ® M12-L 5 poles 50 V Han ® M12 Crimp 50 V 10 A 4A 4A À 0.14 - 0.34 mm² AWG 26 - 22 Á 0.34 - 0.5 mm² AWG 22-20 • 0.1 mm PVC / PE 1.2 - 2.0 mm À 5.5 - 7.2 mm (black) Á 7 - 8.8 mm (light grey) - 25 °C / + 85 °C 7 - 8.8 mm 6.8 - 9.5 mm (black) 4.7 - 6 mm 9 - 12.5 mm 6 - 8 mm (grey) - 25 °C / + 85 °C - 40 °C / + 85 °C - 40 °C / + 85 °C 2.0 - 2.3 mm 4.5 - 5.4 mm (transparent) 7 - 8.8 mm (light grey) - 40 °C / + 85 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C - 5 °C … + 50 °C IP 67 IP 67 IP 65 / IP 67 IP 65 / IP 67 IP 67 10 10 10 10 0.6 Nm / SW 17 0.6 Nm / SW 17 1.5 Nm / SW 22 0.6 Nm / SW 17 7/8“ M12L, 5 poles 0.34 - 0.5 mm² AWG 22 - 20 0.6 Nm / SW 17 1 = wire gauge 0.25 mm² 2 = wire gauge 0.34 mm² Rated current [A] Rated current [A] 1 = wire gauge 0.75 mm² / 1.5 mm² 0.25 - 0.34 mm² AWG 24 - 22 0.34 - 0.5 mm² AWG 22 - 20 • 0.1 mm PVC 1.2 - 2.0 mm Ambient temperature [oC] M12, Crimp 1 = wire gauge 0.34 mm² / 0.5 mm² Ambient temperature [oC] M12L, 5 poles 1 = wire gauge 0.34 mm² 2 = wire gauge 0.5 mm² Rated current [A] Rated current [A] HARAX Ambient temperature [oC] Ambient temperature [oC] 50 . 03 HARAX ® Circular connector Assembly manual HARAX® 1. 1. strip cable 2. assemble HARAX ® elements 3. cut off cable ends 4. screw the connector Nut 2. Strain relief Insert 3. 4. Screw the nut onto the insert until a stop is noticeable. Note! For reconnection cut off the used cable ends and repeat steps 1 to 4. Assembly manual HARAX ® shielded 1. 1. strip cable 2. assemble HARAX ® elements twist screening braid ans push it into the sealing slot 2. 3. Slide ring over the sealing cut off cable ends and the screening braid 4. screw the connector Nut HARAX 3. Strain relief Insert 50 . 04 4. Note! For reconnection cut off the used cable ends and repeat steps 1 to 4. HARAX ® Circular connector Identification Part No. Male Female Drawing Dimensions in mm HARAX ® M8-S straight version, 3 poles straight version, 4 poles straight version, 3 poles for 0.08 - 0.14 mm² 21 02 151 1305 21 02 151 1405 21 02 159 1305 21 02 151 2305 21 02 151 2405 straight version, 3 poles straight version, 4 poles View mating side: 3 poles, male version View mating side: 4 poles, male version HARAX ® M12-S straight version, 4 poles X = View mating side 21 03 111 1405 21 03 111 2405 HARAX ® M12 angled version, 4 poles X = View mating side View mating side: 21 01 140 5081 HARAX angled version, 4 poles 21 01 140 5091 50 . 05 Stock items in bold type Han02_Kap50_AT .indd 5 08 .12 .2008 12:40:33 HARAX ® Circular connector Part No. Identification Male Female Drawing Dimensions in mm HARAX ® M12-L 3 poles, A-coded, with pre-leading contact 3 poles, A-coded 4 poles, A-coded 21 03 212 1400 21 03 212 1306 21 03 212 1305 F 3 poles, A-coded, with pre-leading contact 3 poles, A-coded 4 poles, A-coded 5 poles, A-coded, 0.25 - 0.34 mm², AWG 24 - 22 Cable diameter: 4.7 - 6 mm M 21 03 212 2400 21 03 212 2306 21 03 212 2305 21 03 271 1505 View mating side, male version: HARAX ® M12-L 3 poles with pre-leading contact 3 poles 4 poles 21 03 271 2505 M 5 poles, A-coded, 0.34 - 0.5 mm², AWG 22 - 20 Cable diameter: 6 - 8 mm 21 03 272 1505 21 03 272 2505 F Han® M12 panel feed-through Male, A-coded, 50 cm conductors, 0.5 mm², 5 poles 21 03 311 1501 HARAX 50 . 06 Female, A-coded, 50 cm conductors, 0.5 mm², 5 poles 21 03 311 2501 Stock items in bold type Han02_Kap50_AT .indd 6 08 .12 .2008 12:40:39 HARAX ® Circular connector Part No. Identification Male Female HARAX ® M12-L, screened version 2 poles, B-coded 2 poles + shielding, B-coded 4 poles, D-coded, 0.14 - 0.34 mm², AWG 26-22 0.34 - 0.5 mm², AWG 22-20 4 poles, A-coded Dimensions in mm View mating side, male version: HARAX ® M12-L, screened version 21 03 241 1301 21 03 241 1300 2 poles 21 03 241 1301 B-coded 21 03 281 1405 21 03 282 1405 21 03 221 1405 21 03 241 2301 21 03 241 2300 2-poles, B-coded 2 poles + shielding, B-coded 4 poles, D-coded, 0.14 - 0.34 mm², AWG 26-22 0.34 - 0.5 mm², AWG 22-20 4 poles, A-coded Identification Drawing 3 poles PROFIBUS B-coded 2 poles 21 03 241 2301 B-coded 4 poles Ethernet D-coded 4 poles A-coded 21 03 281 2405 21 03 282 2405 21 03 221 2405 Part No. Drawing Dimensions in mm Han® M12-RJ45 panel feed-through 4 poles, D-coded, angled 21 03 381 4400 Han® M12-RJ45 panel feed-through 4 poles, D-coded, straight 21 03 381 2400 HARAX Han® M12 Gender Changer 4 poles, D-coded 21 03 381 6405 50 . 07 Stock items in bold type Han® M12 panel feed-through Identification Part No. Drawing Dimensions in mm Drawing Dimensions in mm Han® M12 panel feed-through Female, D-coded, 50 cm conductors, AWG 22, 4 poles 21 03 371 2403 Male, D-coded, 50 cm conductors, AWG 22, 4 poles 21 03 371 1403 Han® M12 panel feed-through Female, A-coded, 50 cm conductors, 0.5 mm² Male, A-coded, 50 cm conductors, 0.5 mm² Identification 21 03 311 2400 21 03 311 1402 Part No. HARAX® panel feed-through Female, A-coded 0.14 - 0.34 mm², AWG 26 - 22 5.5 - 7.2 mm 21 03 321 2425 Male, A-coded 0.14 - 0.34 mm², AWG 26 - 22 5.5 - 7.2 mm 21 03 321 1425 Han® M12 panel feed-through Crimp HARAX Female, A-coded 4.5 - 5.4 / 7 - 8.8 mm 50 . 08 21 03 822 2425 Male, A-coded 4.5 - 5.4 / 7 - 8.8 mm 21 03 822 1425 Stock items in bold type Han02_Kap50_AT .indd 8 08 .12 .2008 12:40:56 Han® M12 panel feed-through Identification Part No. Drawing Dimensions in mm Han® M12 panel feed-through for outer termination Female, D-coded, screened version, 360 mm cable1), AWG 26, 4 poles 21 03 383 6407 Han® M12 panel feed-through for inner termination Female, D-coded, screened version, 700 mm cable1), AWG 26, 4 poles 21 03 383 6405 Han® M12 panel feed-through with RJ45 Female, D-coded, screened version, 48 mm cable1), AWG 26, 4 poles 21 03 683 6401 HARAX® panel feed-through Female, D-coded 0.14 - 0.34 mm², AWG 26 - 22 5.5 - 7.2 mm 21 03 381 2425 HARAX Han® M12 panel feed-through Crimp Female, D-coded 4.5 - 5.4 / 7 - 8.8 mm 21 03 882 2425 50 . 09 1) Other length on request Stock items in bold type Han® M12 pcb adapter Technical characteristics: Han® M12 pcb Degree of protection Rated current Rated voltage mating cycles Limiting temperatures Temperature during connection IP 20 max. 4 A (dependent on pcb layout) 50 V max. 100 - 25 °C / + 85 °C - 5 °C / + 50 °C Current carrying capacity The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interruptet current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. Control and test procedures according to DIN IEC 60 512-5. wire gauge 0.75 mm² Rated current [A] M12, A-Kodierung, straight, female, 4 poles wire gauge 0.5 mm² Rated current [A] M12, A-Kodierung, straight, male, 4 poles Ambient temperature [°C] Ambient temperature [°C] wire gauge 0.5 mm² Rated current [A] M12, A-Kodierung, straight, male, 5 poles wire gauge 0.5 mm² Rated current [A] M12, A-Kodierung, straight, female, 5 poles Ambient temperature [°C] 50 . 10 M12, D-Kodierung, gewinkelt, female, 4 poles wire gauge 0.5 mm² wire gauge AWG 22 Rated current [A] M12, D-Kodierung, straight, female, 4 poles Rated current [A] HARAX Ambient temperature [°C] Ambient temperature [°C] Ambient temperature [°C] Han® M12 pcb adapter Identification Part No. Drawing Dimensions in mm Han® M12 Female, D-coded, straight, 4 poles 21 03 371 2415 21 03 381 6410 Han® M12 Male, D-coded, straight, 4 poles 21 03 371 1400 Han® M12 Female, D-coded, angled, 4 poles without fixing hole 21 03 381 4410 HARAX with fixing hole 21 03 381 4412 50 . 11 Stock items in bold type Han® M12 pcb adapter Identification Part No. Drawing Dimensions in mm Han® M12 Female, A-coded, straight 4 poles 21 03 321 6410 5 poles 21 03 321 6510 4 poles 21 03 321 1410 5 poles 21 03 321 1510 Han® M12 Male, A-coded, straight HARAX 50 . 12 Stock items in bold type Notes HARAX 50 . 13 microFX® *HQHUDO'HVFULSWLRQ l l Fibre optic data transmission system for industrial applications Optical transceiver for 1300 nm l Passive interface as coupling unit and panel feed-through l Based on M12 hoods and housings in accordance with IEC 61 076-2-101 l Suitable for multimode glass fibre l 2 supplementary electrical contacts l Degree of protection: IP 65 / IP 67 l Wide temperature range of -40 °C up to +85 °C l Minimum insertion loss: < 0.3 dB ,GHQWL¿FDWLRQ 3DUW1R 7UDQVFHLYHU 7HFKQLFDOFKDUDFWHULVWLFV Mechanical Features 6WRUDJHWHPSHUDWXUH ƒ&ƒ& :RUNLQJWHPSHUDWXUH ƒ&ƒ& 'HJUHHRISURWHFWLRQ ,3 7LJKWHQLQJWRUTXH 1FP Electrical Data 5DWHGYROWDJHRIHOHFWULFDOFRQWDFWV 9'& 5DWHGFXUUHQW $PD[ Optical Data Transceiver for Multimode &HQWHUZDYHOHQJWK Ȝ&  QPXSWRQP 2XWSXWRSWLFDOSRZHUPD[ 30  G%P ,QSXWRSWLFDOSRZHUPLQ 36$7  G%P 'DWDWUDQVPLVVLRQUDWH    0ELWV LQDFFRUGDQFH ZLWK)DVW(WKHUQHW %DVH);,((X 'UDZLQJ 'LPHQVLRQVLQPP 9LHZPDWLQJVLGH  IRUPXOWLPRGH  ZLWKJODVV¿EUHV  QP 3DQHOFXWRXW ‘PP  HARAX 50 . 14 Contact Function Description  9&&5; 5HFHLYHUVXSSO\YROWDJH9 2 5; 5HFHLYHUGDWDRXWSXWQRQLQYHUWHG3(&/  RX5HFHLYHUGDWDRXWSXWLQYHUWHG3(&/  *1' *URXQG 5HFHLYHU  6' 6LJQDO'HIHFW3(&/  566, 5HFHLYHUVLJQDOVWUHQJWKLQGLFDWRURXWSXWDQDORJYROWDJH  5HV 5HVHUYHGIRUIXWXUHXVH  6&/ 9 6'$  7;',6  *1' *URXQG 7UDQVPLWWHU  TX7UDQVPLWWHUGDWDLQSXWLQYHUWHG3(&/  7; 7UDQVPLWWHUGDWDLQSXWQRQLQYHUWHG3(&/  9&&7; 7UDQVPLWWHUVXSSO\YROWDJH9 Stock items in bold type microFX® ,GHQWL¿FDWLRQ 3DUW1R 'UDZLQJ 'LPHQVLRQVLQPP &RQQHFWRU 9LHZ PDWLQJVLGH   RUGHUFRQWDFWVVHSDUDWHO\ 2SWLFDO&RQWDFWV  IRU*,¿EUHV  —P  (OHFWULFDO&RQWDFWV  PP²ZLUHJDXJH  3DQHOIHHGWKURXJK 9LHZPDWLQJVLGH  &RXSOLQJXQLW 9LHZPDWLQJVLGH  HARAX &RUGVHW   /HQJWKP  P  P  P  50 . 15 Stock items in bold type Han® 7/8“ Circular connector Identification Part No. Drawing Dimensions in mm HARAX ® 7/8“ Male 21 04 116 1505 HARAX ® 7/8“ Female 21 04 116 2505 Han® 7/8“ panel feed-through 30 cm conductors, 0.75 mm² Male 21 04 316 1505 Female 21 04 316 2505 HARAX 30 cm conductors, 0.75 mm² 50 . 16 Stock items in bold type Han® M12 Crimp Identification Part No. Drawing Dimensions in mm Han® M12 Crimp Complete length when assembled app. 41.5 mm Male, D-coded 4.5 - 5.4 mm / 7 - 8.8 mm 21 03 882 1405 SW 17 Complete length when assembled app. 41.5 mm Male, A-coded 4.5 - 5.4 mm / 7 - 8.8 mm SW 13 21 03 812 1405 SW 17 Complete length when assembled app. 38 mm Female, A-coded 4.5 - 5.4 mm / 7 - 8.8 mm SW 13 21 03 812 2405 SW 17 SW 13 Order crimp contacts separately Crimping tool 09 99 000 0501 Locator 61 03 600 0023 Single contacts turned male contacts* AWG 22-20 / 0.33-0.52 AWG 26-22 / 0.13-0.33 61 03 000 0073 61 03 000 0094 AWG 22-20 AWG 26-22 turned female contacts* AWG 22-20 / 0.33-0.52 AWG 26-22 / 0.13-0.33 a 8.10 8.10 b 4.0 4.0 c 14.8 14.8 d 1.12 0.90 e 1.66 1.66 f 14.4 14.4 HARAX 61 03 000 0074 61 03 000 0096 50 . 17 * Performance level 1 as per CECC 75301-802, 500 mating cycles, 10 days 4 mixed gas test – IEC 60512 Stock items in bold type ® HARAX Pg 9 panel feed-through Features Technical characteristics O The faston blade was chosen acc. to DIN 46 330 - A 2.8 Rated voltage 32 V Rated current (see current carrying capacity) 4A Each type is delivered with a termination element consisting of a nut, a seal an a splice ring Wire gauge 0.25 - 0.5 mm² 24/7 AWG - 22 AWG Diameter of individual strands • 0.1 mm Conductor insulation material PVC Conductor diameter 1.2 - 1.6 mm Cable diameter 4.0 - 5.1 mm Working temperature - 25 oC … + 85 oC Temperature during connection - 5 oC … + 50 oC Degree of protection IP 67 Termination cycles with the same cross section 10 O O O O Splice ring with Pg 9 For assembly in openings without threads a Pg 9 locknut is available Diameter of the mounting cutout: d = 15.5 mm Current carrying capacity Assembly manual The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted current-loaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. 1. Control and test procedures according to DIN IEC 60 512-3. Strip cable jecket Pg 9, 3 contacts 1 = wire gauge 3 x 0.25 mm² Assemble HARAX® elements a Nut b Strain relief c Insert 2 = wire gauge 3 x 0.5 mm² Rated current [A] 2. 3. Ambient temperature [oC] Put seal and splice ring together Cut off cable ends HARAX 4. 1 = wire gauge 4 x 0.25 mm² 2 = wire gauge 4 x 0.5 mm² 50 . 18 Twist the nut onto the insert until a stop is noticeable Rated current [A] Pg 9, 4 contacts Ambient temperature [oC] ® HARAX Pg 9 panel feed-through Identification Part No. Drawing Dimensions in mm HARAX ® Pg 9 panel feed-through View: Termination side 3 contacts, with pre-assembled 0.5 m / 0.5 mm² pigtail cable 21 01 130 4241 HARAX ® Pg 9 panel feed-through View: Termination side 4 contacts, with pre-assembled 0.5 m / 0.5 mm² pigtail cable 21 01 140 4341 HARAX ® Pg 9 panel feed-through Faston blade termination acc. to DIN 46 330-A 2,8 View: Termination side 3 contacts with faston blades 21 01 130 4011 Termination element M12 HARAX ® 3 contacts Screw cap, splice ring, seal 21 01 010 0001 HARAX Termination element M12 HARAX ® 4 contacts Screw cap, splice ring, seal 21 01 010 0006 50 . 19 Stock items in bold type HARAX ® Pg 13.5 / M20 panel feed-through Technical characteristics Construction type Rated voltage acc. to UL / CSA Rated current (see current carrying capacity) Testing voltage Conductor cross section Diameter of individual strands Outer cable diameter Termination cycles with the same cross section Limiting temperature Temperature during connection Degree of protection Conductor insulation material Max. tightening torque Pg 13,5 3 poles 250 V 4 kV 3 with faston terminals with insulation cap 600 V 16 A Pg 13,5 / M20 4 poles 230/400 V 4 kV 3 600 V 16 A 4 kV (1.2 / 50) 0.75 - 1.5 mm² 4 kV (1.2 / 50) 0.75 - 1.5 mm² • 0.2 mm 6.0 - 9.0 mm • 0.2 mm 6.0 - 9.0 mm 10 - 25 / + 85 oC 10 - 25 / + 85 oC - 5 … + 50 oC IP 67 PVC 8 Nm - 5 … + 50 oC IP 67 PVC 8 Nm Current carrying capacity 1 = wire gauge 0.75 mm² 2 = wire gauge 1.5 mm² Rated current [A] Approval Pg 13,5 3 contacts IEC 60 352-4 DIN 61 984 , VDE Ambient temperature [oC] Pg 13,5 / M20 4 contacts 1 = wire gauge 0.75 mm² 2 = wire gauge 1.5 mm² Rated current [A] Specifications The current carrying capacity is limited by maximum temperature of materials for inserts and contacts including terminals. The current capacity-curve is valid for continuous, not interrupted currentloaded contacts of connectors when simultaneous power on all contacts is given, without exceeding the maximum temperature. Control and test procedures according to DIN IEC 60 512-3. Ambient temperature [oC] Assembly manual 1. 2. 3. Nut Strain relief Insert HARAX ® Pg 13.5 – 3 contacts – is supplied with either faston blades or solder terminals. HARAX ® Pg 13.5 / M20 – 4 contacts – is supplied only with solder termination. HARAX 4. 50 . 20 Connection and disconnection of the cable must only be performed by suitably qualified persons when supply is isolated. The nut must be tightened completely down so that the notches engage on the contact carrier. The opening of the gland always requires a wrench. Note: For reconnection cut off the used cable ends and repeat steps 1 to 4. HARAX ® Pg 13.5 / M20 panel feed-through Identification Part No. HARAX ® Pg 13.5 / 3 contacts with faston blades Drawing Dimensions in mm View: Mating side 21 01 130 1013 HARAX ® Pg 13.5 / 3 contacts with solder termination 21 01 130 1023 HARAX ® Pg 13.5 / 3 contacts with pre-assembled pigtail cable. I = 500 mm, 1.5 mm² 21 01 130 1223 HARAX ® Pg 13.5 / 2 + PE with faston blades View: Mating side 21 01 130 3013 HARAX ® Pg 13.5 / 2 + PE with solder termination 21 01 130 3023 HARAX ® Pg 13.5 / 2 + PE with pre-assembled pigtail cable, I = 500 mm, 1.5 mm² 21 01 130 3233 HARAX ® Pg 13.5 / 4 contacts with solder termination 21 01 140 1023 View: Mating side HARAX ® Pg 13.5 / 3 + PE with solder termination 21 01 140 3023 HARAX ® Pg 13.5 / 4 contacts with pre-assembled strand, I = 500 mm, 1.5 mm² 21 01 140 1323 HARAX ® Pg 13.5 / 3 + PE with pre-assembled strand, l = 500 mm, 1.5 mm² 21 01 140 3333 HARAX ® M20 / 4 contacts with solder termination 21 01 141 1023 View: Mating side HARAX ® M20 / 3 + PE with solder termination HARAX 21 01 141 3023 HARAX ® M20 / 4 contacts with pre-assembled strand, l = 500 mm, 1.5 mm² 21 01 141 1323 HARAX ® M20 / 3 + PE with pre-assembled strand, l = 500 mm, 1.5 mm² Other length on request 50 . 21 21 01 141 3333 Stock items in bold type Notes HARAX 50 . 22 Han® M12 Circular connector System cables with Han® M12 Circular connector, A-coded Han® M8 Circular connector Technical characteristics Han® M12 Circular connector, without PE Rated voltage max. 250 V AC/DC, max. 30 V DC (with LED) Rated current/contact max. 4 A Locking Screw locking M12x1, self securing Recommended torque 0.6 Nm Temperature range (dependent on connected conductor) - 25 °C … +85 °C Degree of protection IP 67 Number of wires / wire gauge 4 x 0.34 mm² Conductor insulation PP (br, ws, bl, sw) Arrangement of insulated strands 42 x 0.1 mm Sheath PUR (UL, CSA) Outer diameter appr. 4.7 mm Bending radius 10 x outer diameter Temperature range (working and storage) -25 °C … + 80 °C Han® M8 Circular connector, without PE Rated voltage max. 60 V AC/DC Rated current/contact max. 4 A Locking Screw locking M8x1, self securing Recommended torque 0.4 Nm Temperature range (dependent on connected conductor) -25 °C … +85 °C Degree of protection IP 67 Number of wires / wire gauge 3 x 0.25 mm² Conductor insulation PP (br, bl, sw) Arrangement of insulated strands 32 x 0.1 mm Sheath PUR (UL, CSA) Outer diameter appr. 4.1 mm Bending radius 10 x outer diameter Temperature range (working and storage) -5 °C … + 80 °C HARAX 50 . 23 Han® M12 Circular connector System cables with Han® M12 Circular connector, A-coded Identification Part No. Drawing Dimensions in mm Han® M12 Circular connector Female straight, Male straight Cable sleeve Cable imprint View mating side Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 03 415 2401 21 03 415 2402 21 03 415 2403 21 03 415 2404 21 03 415 2405 Schematic diagram Han® M12 Circular connector Female angled, Male straight View mating side Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 03 415 5401 21 03 415 5402 21 03 415 5403 21 03 415 5404 21 03 415 5405 Schematic diagram Han® M12 Circular connector Female angled, with LED, Male straight View mating side HARAX Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 03 415 7401 21 03 415 7402 21 03 415 7403 21 03 415 7404 21 03 415 7405 Schematic diagram 50 . 24 Stock items in bold type Han® M12 Circular connector System cables with Han® M12 Circular connector, A-coded Identification Part No. Drawing Dimensions in mm Han® M12 Circular connector Female angled pre-assembled on one end Schematic diagram Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m View mating side 21 03 515 4401 21 03 515 4402 21 03 515 4403 21 03 515 4404 21 03 515 4405 HARAX X® M12 cable-Set Delivery range: Han® M12 connector with individually adaptable cable and HARAX X® M12-S Length: 1,5 m 3,0 m 5,0 m 7,5 m 10,0 m 21 83 515 4401 21 83 515 4402 21 83 515 4403 21 83 515 4404 21 83 515 4405 HARAX X® M12-S (21 03 111 1405) View mating side Han® M12 Circular connector Female angled, with LED pre-assembled on one end Schematic diagram Length: 1,5 m 3,0 m 5,0 m 7,5 m 10,0 m View mating side 21 03 515 7401 21 03 515 7402 21 03 515 7403 21 03 515 7404 21 03 515 7405 HARAX X® M12 cable-Set Delivery range: Han® M12 connector with individually adaptable cable and HARAX X® M12-S Length: 1,5 m 3,0 m 5,0 m 7,5 m 10,0 m HARAX 21 83 515 7401 21 83 515 7402 21 83 515 7403 21 83 515 7404 21 83 515 7405 HARAX X® M12-S (21 03 111 1405) View mating side Stock items in bold type 50 . 25 Han® M8 Circular connector System cables with Han® M8 Circular connector Identification Part No. Drawing Dimensions in mm Han® M8 Circular connector Female angled, Male straight Cable sleeve Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m Cable imprint View mating side 21 02 454 5301 21 02 454 5302 21 02 454 5303 21 02 454 5304 21 02 454 5305 Schematic diagram Han® M8 Circular connector Female angled, with LED Male straight Cable sleeve Cable imprint View mating side Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 02 454 7301 21 02 454 7302 21 02 454 7303 21 02 454 7304 21 02 454 7305 Schematic diagram HARAX 50 . 26 Stock items in bold type Han® M8 Circular connector System cables with Han® M8 Circular connector Identification Part No. Drawing Dimensions in mm Han® M8 Circular connector Female angled pre-assembled on one end Schematic diagram Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 02 554 4301 21 02 554 4302 21 02 554 4303 21 02 554 4304 21 02 554 4305 View mating side HARAX X® M8 cable-Set Delivery range: Han® M8 connector with individually adaptable cable and HARAX X® M8-S Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 82 554 4301 21 82 554 4302 21 82 554 4303 21 82 554 4304 21 82 554 4305 HARAX X® M8-S (21 02 151 1305) View mating side Han® M8 Circular connector Female angled, with LED pre-assembled on one end Schematic diagram Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 02 554 7301 21 02 554 7302 21 02 554 7303 21 02 554 7304 21 02 554 7305 View mating side HARAX X® M8 cable-Set Delivery range: Han® M8 connector with individually adaptable cable and HARAX X® M8-S Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m HARAX 21 82 554 7301 21 82 554 7302 21 82 554 7303 21 82 554 7304 21 82 554 7305 HARAX X® M8-S (21 02 151 1305) View mating side Stock items in bold type 50 . 27 Han® M12 Circular connector System cables with Han® M12 Circular connector, B-coded Technical characteristics Rated voltage max. 125 V AC/ DC Rated current/contact max. 4 A Locking Screw locking M12 x 1 mm, self securing Recommended torque 0.6 Nm Temperature range (male) °C -25 °C … +85 °C (dependent on connected conductor) Degree of protection IP 67 Number of wires / wire gauge 4 x 0.64 mm² Conductor insulation PUR (rt, gn) Arrangement of insulated strands 19 x 0.13 mm Sheath PUR (UL/CSA) Outer diameter appr. 7.8 mm Bending radius 65 x outer diameter Temperature range °C (applicate with fixed cable) -30 °C … + 80 °C Identification Part No. Drawing Han® M12 Circular connector, Male, straight pre-assembled on one end, useable as trailing cable Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 03 549 1301 21 03 549 1302 21 03 549 1303 21 03 549 1304 21 03 549 1305 Schematic diagram 2 4 JUHHQ grün UHG rot VKLHOGLQJ Schirm Han® M12 Circular connector, Male, angled HARAX pre-assembled on one end, useable as trailing cable Length: 50 . 28 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 03 549 3301 21 03 549 3302 21 03 549 3303 21 03 549 3304 21 03 549 3305 Schematic diagram 2 4 JUHHQ grün UHG rot VKLHOGLQJ Schirm Stock items in bold type Han® M12 Circular connector System cables with Han® M12 Circular connector, B-coded Identification Part No. Drawing Han® M12 Circular connector, Female, straight pre-assembled on one end, useable as trailing cable Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 03 549 2301 21 03 549 2302 21 03 549 2303 21 03 549 2304 21 03 549 2305 grün JUHHQ rot UHG 2 Schematic diagram 4 VKLHOGLQJ Schirm Han® M12 Circular connector, Female, angled pre-assembled on one end, useable as trailing cable Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 03 549 4301 21 03 549 4302 21 03 549 4303 21 03 549 4304 21 03 549 4305 grün JUHHQ rot UHG 2 Schematic diagram 4 VKLHOGLQJ Schirm Han® M12 Circular connector, Male, straight Female, straight pre-assembled on one end, useable as trailing cable Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 03 449 4301 21 03 449 4302 21 03 449 4303 21 03 449 4304 21 03 449 4305 Schematic diagram 2 2 4 4 VKLHOGLQJ Schirm Han® M12 Circular connector, Male, angled Female, angled HARAX pre-assembled on one end, useable as trailing cable Length: 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 03 449 6301 21 03 449 6302 21 03 449 6303 21 03 449 6304 21 03 449 6305 Schematic diagram 2 2 4 4 50 . 29 VKLHOGLQJ Schirm Stock items in bold type Han® M12 Accessories, B-coded Identification Part No. Technical characteristics Han® M12-male moving load B-coded 21 03 030 1300 Han® M12-male/female panel feed-through B-coded 21 03 330 1300 Han® M12-panel feed-through Male, B-coded, 20 cm conductor Rated voltage 24 V AC/DC Voltage/contact 4A Thread M16 x 1.5 Degree of protection IP 67 in locked position (EN 60529) Temperature range -25 °C … + 85 °C Rated voltage 250 V AC/DC Voltage/contact max. 4A Termination solder, with pigtails (TPE insulation) assembled 21 03 339 1301 Conductor cross section 0.25 mm² Han® M12-panel feed-through Female, B-coded, 20 cm conductor Degree of protection IP 67 in locked position (EN 60529) Temperature range -25 °C … + 85 °C Rated voltage 250 V AC/DC Voltage/contact max. 4A Termination solder, with pigtails (TPE insulation) assembled 21 03 339 2301 Conductor cross section 0.25 mm² Degree of protection IP 67 in locked position (EN 60529) Temperature range -25 °C … + 85 °C PROFIBUS-cable 100 m raw, PUR cable, useable as trailing cable 21 01 000 0021 HARAX Han® M12 dynamometric screwdriver 50 . 30 Han® M8 dynamometric screwdriver SW 9 09 99 000 0380 SW 13 SW 17 09 99 000 0382 09 99 000 0384 Stock items in bold type Han® M12 Circular connector System cables with Han® M12 Circular connector, D-coded Technical characteristics Han® M12 Circular connector – AWG 22/7 Rated voltage max. 50 V AC/DC Rated current/contact max. 4 A Locking Screw locking M12x1, self securing Recommended torque 0.6 Nm Temperature range - 20 °C … +60 °C Degree of protection IP 67 Number of wires / wire gauge 2 x 2 x AWG 22/7 Conductor insulation PE (yellow, orange, white, blue) acc. to PROFInet® Arrangement of insulated strands 7 x 0.25 mm Sheath PUR (UL, CSA) Outer diameter appr. 6.5 mm Bending radius 10 x outer diameter Temperature range -20 °C … + 60 °C Han® M12 Circular connector – AWG 26 Rated voltage max. 50V AC/DC Rated current/contact max. 2 A Locking Screw locking M12x1, self securing Recommended torque 0.6 Nm Temperature range - 5 °C … +60 °C Degree of protection IP 67 Number of wires / wire gauge 2 x 2 x AWG 26 Conductor insulation PE (white/orange, orange, white/green, green) acc. to EIA/ TIA 568B Arrangement of insulated strands 7 x 0.16 mm Sheath PUR (UL, CSA) Outer diameter appr. 5.6 mm Bending radius 10 x outer diameter Temperature range -5 °C … + 60 °C HARAX 50 . 31 Han® M12 Circular connector System cables with Han® M12 Circular connector, D-coded Identification Part No. Pre-assembled and tested system cables for structured cabling of industrial Ethernet networks, based on Han® M12 Circular connectors, D-coded Drawing Dimensions in mm Cable type: Shielded Twisted Pair Standard Cable Mating interface: M12 D-coded acc. to IEC 61 076-2-101 Transmission performance acc. to ISO/IEC 11801:2002: Class D, 100% tested Degree of protection IP 65 / IP 67 (when mated) Pin assignment 2 x Han® M12 Circular connector, D-coded, straight Length: 1 m 3m 5m 10 m 15 m 25 m 40 m 21 03 483 1401 21 03 483 1403 21 03 483 1405 21 03 483 1410 21 03 483 1415 21 03 483 1425 21 03 483 1440 Conductor colour EIA/TIA 568B Contact assignment Signal Function Conductor colour PROFInet® TD+ Transmission Data+ Yellow White/ Orange 1 TD- Transmission Data- Orange Orange 3 RD+ Receiver Data+ White White/Green 2 RD- Receiver Data- Blue Green 4 cable: AWG 26 / 0.14 mm² other length on request HARAX 50 . 32 2 x Han® M12 Circular connector, D-coded, straight Length: 1 m 3m 5m 10 m 15 m 25 m 40 m 21 03 485 1401 21 03 485 1403 21 03 485 1405 21 03 485 1410 21 03 485 1415 21 03 485 1425 21 03 485 1440 cable: AWG 22 / 0.34 mm² other length on request Stock items in bold type Han® M12 Circular connector System cables with Han® M12 Circular connector, D-coded Identification Part No. Pre-assembled and tested system cables for structured cabling of industrial Ethernet networks, based on Han® M12 Circular connectors, D-coded Drawing Dimensions in mm Cable type: Shielded Twisted Pair Standard Cable Mating interface: M12 D-coded acc. to IEC 61 076-2-101 Transmission performance acc. to ISO/IEC 11801:2002: Class D, 100% tested Degree of protection IP 65 / IP 67 (when mated) Pin assignment 1 x Han® M12 Circular connector, D-coded, straight Length: 1 m 3m 5m 10 m 25 m 40 m 21 03 583 1401 21 03 583 1403 21 03 583 1405 21 03 583 1410 21 03 583 1425 21 03 583 1440 Conductor colour EIA/TIA 568B Contact assignment Signal Function Conductor colour PROFInet® TD+ Transmission Data+ Yellow White/ Orange 1 TD- Transmission Data- Orange Orange 3 RD+ Receiver Data+ White White/Green 2 RD- Receiver Data- Blue Green 4 cable: AWG 26 / 0.14 mm² other length on request 1 x Han® M12 Circular connector, D-coded, straight Length: 1 m 3m 5m 10 m 25 m 40 m 21 03 585 1401 21 03 585 1403 21 03 585 1405 21 03 585 1410 21 03 585 1425 21 03 585 1440 cable: AWG 22 / 0.34 mm² HARAX 50 . 33 other length on request Stock items in bold type Han® M12 Circular connector Identification Part No. Drawing Dimensions in mm 1 x Han® M12 Circular connector, straight pre-assembled on one end, 8 poles Length: 1.0 m 21 03 514 1801 3.0 m 21 03 514 1803 5.0 m 21 03 514 1805 Han® M12 Circular connector with IDC termination technology, 8 poles 21 03 121 1801 Han® M12 pcb 8 poles 21 03 311 2801 HARAX 50 . 34 Stock items in bold type Circular connector 7/8’’ Overmolded cordsets 7/8’’ Technical characteristics Degree of protection IP 67 Temperature range applies to moved cable cables permanently installed -20 °C … +80 °C -50 °C … +80 °C Rated current max. 8 A every contact (+40 °C) Rated voltage 230 / 400 V Rated impulse voltage 3 kV Pollution degree 3 Material group Category I acc. to IEC 60 664-1 Cable data Jacket material PUR Jacket colour grey Wire isolation TPM Wire colours brown, white, blue, black, green/yellow Wire gauge 5 x 1.5 mm² Standards UL / CSA HARAX 50 . 35 Circular connector 7/8’’ Overmolded cordsets 7/8’’ Identification Part No. Drawing Dimensions in mm Overmolded cordsets 7/8’’ Female straight 5 pin Length: 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 04 516 2501 21 04 516 2502 21 04 516 2503 21 04 516 2504 21 04 516 2505 1.5 m 3.0 m 5.0 m 7.5 m 10.0 m 21 04 516 4501 21 04 516 4502 21 04 516 4503 21 04 516 4504 21 04 516 4505 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 04 416 1501 21 04 416 1502 21 04 416 1503 21 04 416 1504 21 04 416 1505 0.3 m 0.6 m 1.0 m 1.5 m 2.0 m 21 04 416 3501 21 04 416 3502 21 04 416 3503 21 04 416 3504 21 04 416 3505 Schematic diagram View mating side Overmolded cordsets 7/8’’ Female angled 5 pin Length: Schematic diagram View mating side Overmolded cordsets 7/8’’ Male-Female straight 5 pin Length: Schematic diagram View mating side Schematic diagram View mating side Overmolded cordsets 7/8’’ Male-Female angled 5 pin Length: HARAX 50 . 36 Stock items in bold type Han02_Kap50_AT .indd 36 08 .12 .2008 12:42:28 Accessories Identification Part No. Drawing Dimensions in mm Seal M12 2.9 - 4.0 mm 4 - 5.1 mm 21 01 010 2011 21 01 010 2001 Seal M12-L 3 poles: 5.5 - 7.2 mm 4 + 5 poles: 6 - 8 mm 21 01 010 2003 21 01 010 2007 Seal M8 for 2.5 - 3.5 mm cable Ø for 3.2 - 4.4 mm cable Ø for 4.2 - 5.4 mm cable Ø 21 01 010 2008 21 01 010 2004 21 01 010 2005 Set of 3 seals for HARAX ® M8-S for 2.5 - 3.2 mm cable Ø for 3.2 - 4.0 mm cable Ø for 4.0 - 5.1 mm cable Ø 21 01 010 2013 Seal Pg 13.5 / M20 6 - 9 mm 21 01 010 2002 HARAX Cap M12 21 01 000 0003 50 . 37 Stock items in bold type Accessories Identification Part No. Drawing Dimensions in mm Lock nut Pg 9 nickel plated 21 01 000 0008 Lock nut M16 nickel plated 21 01 000 0010 Lock nut 7/8’’ nickel plated 21 01 000 0023 Lock nut Pg 13.5 nickel plated 21 01 000 0020 Lock nut Pg 13.5 21 01 000 0007 Lock nut M20 21 01 000 0009 HARAX Socket wrench 21 01 000 0001 50 . 38 Stock items in bold type
21 03 311 2400 价格&库存

很抱歉,暂时无法提供与“21 03 311 2400”相匹配的价格&库存,您可以联系我们找货

免费人工找货
21033112400
    •  国内价格 香港价格
    • 1+258.228621+31.22049
    • 10+210.4875910+25.44848
    • 25+194.0595725+23.46229
    • 50+182.4996750+22.06467
    • 100+171.62997100+20.75050
    • 250+168.13789250+20.32830

    库存:124

    21033112400
    •  国内价格
    • 1+190.61606
    • 50+186.95056

    库存:12