Directory chapter 20
Page
Summary of shell housings and accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.02
Shell housing C . . . . . . . . . . . . . . . . . . . . . . . . . .
20.04
Shell housing A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.08
Shell housing B . . . . . . . . . . . . . . . . . . . . . . . . .
20.10
Shell housing D 15 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.14
Open hood G . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.17
Junction element O . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.17
Shell housings D 20/2 and D 20/4 . . . . . . . . . . . . .
20.18
EMC housing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.24
Shell housings D 20/2 and D 20/4 metallised. . . . .
20.25
Shell housings D 20 metal . . . . . . . . . . . . .
20.28
Electronic connectors in Heavy Duty Housings . . . . . . . . . . . . . . . . . . . . . . . . .
20.30
Application examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
20.32
Shell
housings
Shell housings
20
.
01
Summary shell housings and accessories
Appropriate connectors in
shell housings
Types
B, C, D, E
Type
F
Types
F, H, MH
Types
E, F, H, MH
Check list:
How to order
shell housings
and accessories.
Types
F, H, MH
… 9968
The Part No. is stated.
… 9930
Shell housings
Cable insert
C
A
B
G
O
09 02 064 0501
09 02 064 0502
09 03 096 0501
09 05 048 0501
09 06 048 0501
09 06 048 0401
09 06 048 0402
09 06 048 0503
09 06 048 0504
09 06 048 0505
09 06 000 9957
09 06 000 9968
°09 06 000 9930°
09 02 000 9910
09 02 000 9911
09 06 000 9914
09 06 000 9915
Insert for LED
09 06 000 9917
Locking lever
09 02 000 9902
09 02 000 9903
Locking screws
09 02 000 9909
M 2.5 x 16
M 2.5 x 00
09 02 000 9909
M 2.5 x 16
M 2.5 x 00
09 02 000 9909
M 2.5 x 16
M 2.5 x 00
M 2.5 x 12
M 2.5 x 00
09 02 000 9909
M 2.5 x 16
M 2.5 x 00
M 2.5 x 22
Supplied with the
interface connector I
C
Order 2 pieces, in some cases each with
different Part Nos. for left and right hand
Order
2 sets
° order 2 pieces
for fixing elements
with male connectors
for interface
connectors U
for interface
connectors I
Fixing brackets
Supplied
with the
shell housing
09 06 000 9913
09 06 000 9919
09 06 000 9926
M 2.5 x 20
M 2.5 x 00
09 06 000 9926
M 2.5 x 20
M 2.5 x 00
09 06 000 9955
M 2.5 x 26
Supplied
with the
shell housing
Supplied
with the
shell housing
Supplied
with the
shell housing
09 06 000 9926
M 2.5 x 20
M 2.5 x 00
A
B
B
B
09 02 000 9919
09 06 000 9901
09 02 000 9920
09 06 000 9902
09 06 000 9907
09 06 000 9966
09 06 000 9908
09 06 000 9967
09 06 000 9907
09 06 000 9966
09 06 000 9908
09 06 000 9967
09 06 000 9907
09 06 000 9966
09 06 000 9908
09 06 000 9967
09 02 000 9921
09 02 000 9922
09 06 000 9905
09 06 000 9906
09 06 000 9909
09 06 000 9910
09 06 000 9909
09 06 000 9910
09 06 000 9909
09 06 000 9910
for 19” racks
Shell
housings
for male
connectors
Multiple
fixing
left
Single
fixing
left
right
right
B
B
09 06 000 9933
09 06 000 9933
only … 9930
09 06 000 9933
09 06 000 9933
for female
connectors
Multiple
fixing
left
right
Fixing brackets
for inverse
male connectors
on pcb
R
R1
R 32
09 02 000 9953
09 02 000 9954
Distance fixing
brackets
for piggyback connectors
Type D top
Type E bottom
Type F top
bottom
20
.
02
09 04 000 9907
09 04 000 9906
09 06 000 9936
09 06 000 9937
09 04 000 9907
09 04 000 9906
09 06 000 9936
09 06 000 9937
Protection strip
09 06 000 9929
Protection and fixing strip
09 06 001 9909
for 20 mm shell housing
for 20 mm shell housing
Female connectors
Male connectors
Detailed system description see chapter 00
Summary shell housings and accessories
Appropriate connectors
in shell housings
Types
F, H, MH
Types
F, H, MH
D 15
D 20
Types
F, H, MH
Types
F, H, MH
Check list:
How to order
shell housings
and accessories.
The Part No. is stated.
Shell housings
09 06 048 0515
09 06 948 0521
09 06 948 0522
09 06 000 9988
09 06 000 9989
09 06 900 9988
09 06 000 9986
09 06 000 9987
09 06 900 9986
09 06 900 9987
09 06 000 9926
M 2,5 x 16
M 2,5 x 00
Supplied
with the
shell housing
Supplied
with the
shell housing
Supplied
with the
shell housing
B
B
B
B
09 06 000 9907
09 06 000 9966
09 06 000 9907
09 06 000 9966
09 06 000 9995
09 06 000 9997
09 06 900 9907
09 06 900 9966
09 06 900 9995
09 06 900 9997
09 06 900 9997
09 06 000 9908
09 06 000 9967
09 06 000 9996
09 06 000 9998
09 06 900 9908
09 06 900 9967
09 06 900 9996
09 06 000 9909
09 06 001 9934
09 06 900 9909
09 06 901 9934
09 06 000 9910
09 06 001 9935
09 06 900 9910
09 06 901 9935
09 06 001 9909
09 06 001 9909
Insert for LED
Order 2 pieces, in some cases each with
different Part Nos. for left and right hand
Locking screws
Order
2 sets
for fixing elements
with male connectors
D 20 metal
09 06 048 0521
09 06 048 0522
Cable insert
Locking lever
D 20 metallised
09 06 848 0550
09 06 848 0551
Supplied
with the
shell housing
for interface connectors U
for interface connectors I
Fixing brackets
for 19” racks
left
right
Single
fixing
left
right
09 06 000 9908
09 06 000 9967
09 06 000 9909
09 06 000 9910
09 06 900 9996
09 06 901 9924
09 06 901 9925
Shell
housings
for male
connectors
Multiple
fixing
B
for female
connectors
Multiple
fixing
left
09 06 000 9933
right
09 06 000 9933
Protection and fixing strip
for 20 mm shell housing
20
.
03
Female connectors
Male connectors
Detailed system description see chapter 00
Shell housing C for types B, C, D, E and har-bus® 64
1 Shell
1x
2 Cover
1x
3 Blinding plate
1x
4 Cable tie
1x
5 Blinding piece
2x
6 Grounding plate
1x
7 Screw BZ 2.2 x 9.5
DIN ISO 1481
er t
d
un
bl
ca
Ro
g
ers
lev
n
cki
Lo
2x
3
ws
cre
2x
2x
gs
5
8 Screw
a) BZ 2.9 x 6.5
DIN ISO 1482
ns
ei
kin
oc
L
4
3x
9
)0
b), c), d) BZ 2.9 x 13
DIN ISO 1483 3x
(10
6
5
(15
1
7
1
50
02
0
64
0
mm
)
mm
09
02
4
06
02
05
2a
7
2b
ale
eB
nn
Cr
fem
p
m
ter
im
Shell
housings
le
C
pe
a
fem
Ty
le
eD
a
fem
c
Cr
nal
Sol
2c
l
ina
90
term
(20
0
m)
m
nal
rmi
te
der
tor
l
ina
Sol
rm
p te
Crim
2d
8
Typ
r
cto
ne ctor
n
co ne
ale con
m
fe ale
fem
p
Crim
l
ina
Sol
nal
rmi
te
der
term
E ® 64
ype bus
T
20
r.
ha
04 Moulding material: thermoplastic resin, glass-fibre filled, UL 94-V0
01
05
rmi
te
imp
ec
n
on
c
der
tor
ne
m
l
Typ
n
co
5
0
m)
01
05
ina
to
ec
co
8
04
90
(15
r
3
6
09
Separate accessories
for housings
Fitting female connectors
Flat cable access
Housing parts supplied
Shell housing C for types B, C, D, E and har-bus® 64
I
Identification
Shell housing C
for female connectors
type B
I
Part No.
II
Drawing
III
Dimensions in mm
10 mm
09 02 064 0501
Type B
15 mm
09 02 064 0502
Type B
Shell housing C
for female connectors
types C, D
15 mm
09 03 096 0501
Type C
Shell housing C
for female connectors
type E,
har-bus® 64
III
Type D
20 mm
09 05 048 0501
Shell
housings
II
Type E, har-bus® 64
Blanking pieces
Inserts see
page 20.07
Grounding plate
Cable tie
1)
BZ 2.2 x 9.5
DIN ISO 1481
Possible access for flat cable (18 x Ø 1.27). Remove the blanking piece.
20
.
05
Shell housing C
I
III
IV
Accessories
Identification
Part No.
II
Drawing
Dimensions in mm
Locking lever for
shell housing C
I
left
09 02 000 9902
right
09 02 000 9903
Shell housing C
left
right
Male connector type B, C, D, E
Fixing brackets C
for male connectors
Multiple fixing
II
left
09 02 000 9919
Shell housing C
left
right
Male connector type B, C, D, E
right
09 02 000 9920
Single fixing
M 2.5 x 16
DIN EN ISO
7045
III
Shell
housings
left
09 02 000 9921
Shell housing C
left
right
09 02 000 9922
right
Male connector type B, C, D, E
Fixing brackets R
for inverse male
connectors
on pcb’s
IV
20
.
06
M 2.5 DIN EN ISO 4036
for 19“ racks according
to DIN EN 60 297,
part 3-101
M 2.5 x 16
DIN EN ISO
7045
R1
09 02 000 9953
R 32
09 02 000 9954
Shell housing C
M 2.5
DIN EN
ISO 4036
Male connector type Q, R
See application example 4, chapter 01
BZ 2.2 x 9.5
DIN ISO 7049
Shell housing C
II
I
Accessories
Identification
Part No.
Drawing
Dimensions in mm
for shell housing C
09 02 064 0501
09 02 000 9910
Supplied with:
Round cable insert 1x
Blinding piece A 1x
Blinding piece B 1x
Cable tie 1x
max. ø 6.5
Round cable insert
2 x ø 6.5
Cable tie
Round cable insert
2 x ø 11.5
for shell housings C
09 02 064 0502
09 03 096 0501
09 05 048 0501
09 02 000 9911
max. ø 11.5
I
Cable tie
Shell
housings
Supplied with:
Round cable insert 1x
Blinding piece A 1x
Blinding piece B 1x
Cable tie 1x
II
09 02 000 99091)
M 2.5 x 16
DIN EN ISO 7045
Locking
screws
Shell housing C
Interface connector U
20
.
07
1)
Order 2 pieces for one shell housing
Shell housing A for type F
5
6
g
kin
oc
4
7
ws
cre
9
)0
nn
o
ec
al
fem
e
Typ
(15
r
cto
e
06
0
48
0
mm
F
3
1a
7
Cr
t
mp
i
n
al
fem
06
9
)0
(15
r
cto
e
nn
on
ati
n
5
Shell
housings
6
L
1c
g
kin
oc
fem
Typ
ale
s
ew
r
c
s
n
co
2x
02
)
ne
(15
er m
pt
1x
0
48
1
0
2x
1c Shell
1x
2c Cover
1x
4 Cable clamp
2x
5 Screw
BZ 2.9 x 9.5
DIN ISO 1481
4x
6 Hexagonal nut M3
DIN EN ISO 4032 4x
7 Screw
M3 x 12
DIN EN ISO 1207 4x
eF
7
rim
mm
0
09
4
80
4
60
r
cto
2c
n
tio
ina
5 Screw
BZ 2.9 x 9.5
DIN ISO 1481
7 Screw
M3 x 12
DIN EN ISO 1207 4x
6
4
7
1x
6 Hexagonal nut M3
DIN EN ISO 4032 4x
7
C
4 Cable clamp
1b Casing shell
1b
rim
1x
mm
eF
p
y
T
mi
3 Blinding piece
40
s
o
ec
1b
2x
ws
cre
ng
cki
Lo
er
pt
2x
7 Screw
M3 x 12
DIN EN ISO 1207 2x
6
6
7
1a Casing shell
6 Hexagonal nut M3
DIN EN ISO 4032 2x
tio
ina
erm
1
50
s
L
1a
2x
6
C
20
.
08 Moulding material: thermoplastic resin, glass-fibre filled, UL 94-V0
Separate accessories
for housings
Fitting female connectors
Cable access
Housing parts supplied
Shell housing A for type F
III
I
Identification
Part No.
IV
II
Drawing
Dimensions in mm
Shell housing A
Side entry
15 mm
09 06 048 0501
I
Flat cable entry
Top entry
II
15 mm
09 06 048 0401
15 mm
09 06 048 0402
Cable clamp
incl. screw
09 00 000 5329
See à + Ä on page 20.08
Fixing brackets A
for male connectors
for 19” racks according
to DIN EN 60 297,
part 3-101
Shell
housings
Identification recess 12.2 x 64.8
Shell housing A
left
09 06 000 9901
Male connector type F
Multiple fixing
III
right
09 06 000 9902
left
1)
Single fixing
right
nut and screw not supplied with bracket
left
09 06 000 9905
Male connector type F
IV
right
09 06 000 9906
left
right
20
.
09
Shell housing B for types F, H and MH
1 Shell
1x
2 Cover
1x
3 Blinding plate
1x
4 Cable clamp
2x
5 Screw BZ 2.9 x 9.5
DIN ISO 1481
4x
6 Blinding piece
2x
7 Grounding plate
1x
D
LE
r
. fo
g
e.
s
er t
Ins
er t
ns
ei
l
ab
c
nd
u
Ro
8 Screw
a) BZ 2.9 x 9.5
DIN ISO 1483
3x
b), c) BZ 2.9 x 13
DIN ISO 1483
g
kin
oc
ers
lev
L
3x
5
3
2x
x
s2
ew
cr
gs
6
n
cki
0
m)
6
8
04
90
1
(20
0
m)
90
(20
4
04
05
m
7
6
03
05
m
4
5
6
8
04
90
(15
Lo
6
8
04
0
m)
m
2a
2b
rt
Shell
housings
tor
ale
e
Typ
F
fem
ec
onn
c
ge
Ca
tor
ale
Typ
fem
n
con
8
S
nal
i
term
le
ma
p
ec
eH
p
Crim
e
old
2c
l
na
i
erm
m
cla
H
eM
s
Fa
l
er
pt
e
ac
erf
na
mi
eF
int
p
Ty
l
ina
erm
pt
rim
co
fe
Typ
ton
im
Cr
r
cto
e
nn
C
20
.
10 Moulding material: thermoplastic resin, glass-fibre filled, UL 94-V0
n
co
tor
c
ne
05
05
I
Separate accessories
for housings
Fitting female connectors
Fitting male connectors
Flat cable access
Housing parts supplied
Shell housing B for types F, H and MH
II
III
Identification
Part No.
I
Drawing
Dimensions in mm
Shell housing B
15 mm
09 06 048 0503
II
20 mm
09 06 048 0504
III
20 mm
09 06 048 0505
Inserts see page 20.13
Blanking piece
Grounding plate
Shell
housings
I
1)
Possible access for flat cable (18 x ø 1.27). Remove the blanking piece
20
.
11
Shell housing B
I
III
II
Accessories
Identification
Part No.
Drawing
Dimensions in mm
Locking lever
for shell housing B
09 06 048 0503
09 06 000 99131)
I
Shell housing B
1)
Order 2 pieces
for one shell housing
left
09 06 000 9913
09 06 000 99261)
right
Male connector type F, H, MH
right
09 06 000 9919
Locking screws
II
left
M 2.5 x 20
09 06 048 0504
09 06 048 0505
Shell housing B
Male connector type F, H, MH
1)
Order 2 pieces
for one shell housing
M 2.5
DIN EN
ISO
4036
Fixing brackets B
for male connectors
for 19” racks according
to DIN EN 60 297,
part 3-101
Shell
housings
Multiple fixing
without nut
with nut
M 2.5 DIN 562
left
09 06 000 9907
Shell housing B
left
right
09 06 000 9908
right
Male connector type F, H, MH
left
09 06 000 9966
right
09 06 000 9967
Single fixing
without nut
III
20
.
12
left
09 06 000 9909
right
09 06 000 9910
Shell housing B
left
right
Male connector type F, H, MH
Shell housing B
II
IV
III
I
Accessories
Identification
Part No.
Drawing
Dimensions in mm
Fixing brackets B
for female connectors
for 19” racks according
to DIN EN 60 297,
part 3-101
Multiple fixing
09 06 000 99331)
I
1)
Order 2 pieces
for one female connector
M 2.5 x 8
DIN EN
ISO 12072)
2)
Female connector type F
nut and screw not supplied with fixing brackets
Round cable insert
2 x ø 10
for shell housings B
09 06 048 0503
09 06 048 0504
09 06 000 9914
Supplied with:
Round cable insert 1x
Blinding piece 1x
Round cable insert
2 x ø 12.5
II
for shell housing B
09 06 048 0505
09 06 000 9915
Shell
housings
Supplied with:
Round cable insert 1x
Blinding piece 1x
III
for shell housing B
09 06 048 0505
09 06 000 9917
pcb
35.5 x 17 x 1.5
Insert for LED
Protection strip
IV
09 06 000 9929
Used with shell housings
type B for front side access
09 06 048 0504
09 06 048 0505
Male connector type F
20
.
13
Shell housing D 15 for types F, H and MH
3
cal
ni
cha
Me
g
idin
gu
ws
cre
und
gro
gs
g
kin
tin
c
a
m
Lo
irst
4
2
5
ion
ect
n
con
2x
f
and
5
51
9
)0
1
(15
06
0
48
0
mm
3
6
1
4
7
6
ale
F
pe
tor
c
ne
n
co
fem
Ty
r
r te
Shell
housings
e
p
Crim
ld
So
nal
l
na
mi
le
ma
ec
n
on
c
fe
eH
Typ
i
term
mp
la
ec
g
Ca
tor
le
ma
tor
c
e
nn
co
l
ina
p
im
2 Blinding plate
1x
3 Cable tie
2x
4 Blinding piece
2x
5 Hexagonal nut M2.5
DIN EN ISO 4035
2x
6 Screw BZ 2.9 x 9.5
DIN ISO 1481
2x
7 Screw M2.5 x 12
DIN EN ISO 7045
2x
Typ
ton
Cr
2x
fe
H
eM
s
Fa
m
ter
1 Casing shell
F
pe
e
ac
erf
n
co
tor
c
ne
I
int
Ty
Separate accessories
for housings
20
.
14
l
er
pt
im
Cr
na
mi
Moulding material: thermoplastic resin,
glass-fibre filled, UL 94-V0
Fitting female connectors
Fitting male connectors
Housing parts supplied
Shell housing D 15 for types F, H and MH
II
I
Identification
Part No.
Drawing
III
Dimensions in mm
Shell housing D 15
I
Cable tie 2 x
Blanking
pieces
2 x BZ 2.2 x 9.5 DIN ISO 1481
15 mm
09 06 048 0515
M 2.5
DIN EN ISO
4 036
Shell
housings
M 2.5 x 12
DIN EN ISO
7045
Mechanical guiding
and first mating
ground connection
II
09 06 000 9961
Locking screws
Shell housing D 15
III
09 06 000 99261)
Male connector type F, H, MH
1)
Order 2 pieces
for one shell housing
M 2.5
DIN EN
ISO
4 036
20
.
15
Shell housing D 15
I
II
III
Accessories
Identification
Part No.
Drawing
Dimensions in mm
Fixing brackets B
for male connectors
for 19” racks according
to DIN EN 60 297,
part 3-101
Shell housing D 15
Multiple fixing
left
09 06 000 9907
without nut
I
with nut
M 2.5 DIN 562
left
right
09 06 000 9908
right
Male connector type F, H, MH
left
09 06 000 9966
right
09 06 000 9967
Single fixing
without nut
left
right
09 06 000 9910
right
Male connector type F, H, MH
Shell
housings
II
Shell housing D 15
left
09 06 000 9909
Fixing brackets B
for female connectors
for 19” racks according
to DIN EN 60 297,
part 3-101
Multiple fixing
III
20
.
16
1)
Order 2 pieces
for one female connector
09 06 000 99331)
Female connector type F
M 2.5 x 8
DIN EN
ISO 12072)
2)
nut and screw not supplied with fixing brackets
Open hood G, junction element O, locking lever
II
Identification
Open hood G
Part No.
I
for types E, F, H
and MH, for applications
A B C
Supplied with:
Open hood 1x
Locking screw 2x
(09 06 000 9958)
Cable tie 1x
Screw 2x
Open hood G
09 06 000 9957
III
IV
Drawing
2 x BZ 2.2 x 9.5 DIN ISO 1481
I
Dimensions in mm
Cable tie 1 x
II
for types E, F, H
and MH, for application
A
B
C
C
U element
Junction element O
for type F
IV
Supplied with:
Junction element 2x
Cable tie 2x
Screw 2x
Screw M2.5 x 20 2x
09 06 000 9968
Locking lever
for type F, H and MH
Female connector
Female connector
I element
Male connector
Fixing
brackets B
2 x M 2.5 x 20
DIN EN ISO 7045
Shell
housings
09 06 001 9939
2 x BZ 2.2 x 9.5 DIN ISO 1481
Supplied with:
Open hood 1x
Pre-assembled,
undetachable locking
screw 2x
Cable tie 1x
Screw 2x
M 2.5 x 8
DIN EN ISO 12072)
09 06 000 99301)
III
Female connector
M 2.5 DIN EN ISO 4 0322)
M 2.5 x 8
DIN EN ISO 12072)
09 06 000 99111)
Female connector type F
2)
1)
Order 2 pieces
for one female connector
M 2.5 DIN EN ISO
4 0322)
nut and screw
not supplied
with locking
levers
20
.
17
Shell housing D 20/2 for types F, H and MH
m)
b
pc 2.5 m ED
L
x 1 . for
5
.
g
(79 e.
ED
rL
. fo
.5
d:
ire
u
req
s
er t
r
. fo
D
LE
p
g
e.
.5
79
(
cb
2
x1
g
e.
)
m
m
Ins
for
.
.g
se
D
LE
er t
Ins
nd
u
Ro
t
Fla
1 Shell
1x
2 Cover
1x
3 Screw
(09 06 000 9993)
2x
4 Locking washer 2.3
DIN 6799
2x
5 Cable clamp
2x
6 Blinding piece
2x
7 Screw BZ 2.2 x 9.5
DIN ISO 7049
er t
ins
le
ab
c
er t
ns
ei
4
7
bl
ca
3
3
5
4
1
6
6
7
1
52
8 0 21
4
05
60
9 0 948
0
)
06
mm 09
(20 mm)
(20
7
Shell
housings
r
cto
ne
on
c
ale
lde
So
2
mp
la
ec
g
Ca
or
ect
ton
s
Fa
n
on
c
ale
eH
Typ
rm
r te
p te
Crim
fem
Typ
fem
or
ect
er
pt
l
na
mi
im
Cr
n
on
c
ale
20
.
18
l
ina
al
rmin
fem
H
x
eM
tor ts 2
p
c
y
e
e
T
n
k
con brac
e
l
g
Ma Fixin
g
din
Co
5
eF
10x
pcb
Moulding material: thermoplastic resin, glass-fibre filled, UL 94-V0
g
din
Co
Separate accessories
for housings
Fitting female connectors
Fitting male connectors
Fixing brackets
Housing parts supplied
Shell housing D 20
Fitting female connectors
Part-No.
Type
D 20/2
D 20/4
D 20 metal
D 20 metal HF
X
X
X
X
X
X
09 06 2__ _823
F with open solder lugs
X
09 06 2__ _853
F with closed solder lugs
X
09 06 248 3201
F moulding for crimp contacts
X
09 06 215 2871
H for faston
X
X
X
09 06 015 2813
H with cage clamps
X
X
X
09 06 231 2881
MH moulding for crimp contacts
X
X
X
X
09 06 2__ _853
Order example:
7 = performance level 3
6 = performance level 2
2 = performance level 1
32 = 32 contacts
48 = 48 contacts
1)
Shell
housings
Technical characteristics
D 20/2
D 20/2
metallised1)
D 20/4
D 20/4
metallised1)
D 20 metal
D 20 metal HF
Part No.
09 06 048 0521
09 06 948 0521
09 06 048 0522
09 06 948 0522
09 06 848 0550
09 06 848 0551
Material
Polycarbonate
Polycarbonate
Polycarbonate
Polycarbonate
Zinc alloy
Zinc alloy
Surface
none
nickel/copper
none
nickel/copper
nickel-plated
nickel-plated
Weight [g]
36
44
43
52
182
188
Cable entries
side (2 x),
top (2 x)
side (2 x),
top (2 x)
side (4 x)
side (4 x)
side (2 x),
top (2 x)
side (2 x)
top (2 x)
Protection
IP 20
IP 20
IP 20
IP 20
IP 20
IP 20
upper temperature limit is +105 °C
20
.
19
Shell housing D 20 for types F, H and MH
I
II
III
Identification
Part No.
Shell housing
D 20/2
Dimensions in mm
Order inserts separately
Two side
cable entries
I
Drawing
Blanking piece 2 x
20 mm
09 06 048 0521
Shell housing
D 20/4
Four side
cable entries
II
Supplied with:
Shell 1x
Cover 1x
Locking screw 2x
Locking washer 2.3 2x
Screw BZ 2.2x9.5 12x
Blinding piece 3x
Cable clamp 2x
20 mm
09 06 048 0522
Shell
housings
Inserts e. g. for LED*
for 55 mm height
09 06 000 9986
pcb
for 60 mm height
09 06 000 9987
pcb
Round cable insert*
2 x ø 11
III
09 06 000 9988
Flat cable insert*
09 06 000 9989
20
.
20
* Fits D 20/2
Shell housing D 20
II
III
I
Coding
Identification
Part No.
Drawing
Dimensions in mm
Code comb for
shell housing3)
(can also be used as a
blanking cover)
I
09 06 000 9984
Coding pin3)
II
1)
09 06 001 99051)
Order 13 pieces per code comb
Order 13 pieces
per code comb
Code comb
for male connectors3)
III
09 06 000 9985
Shell
housings
Mounting possibilities
for the code comb in the
shell housing D 20/2
2)
Use the lower slot when
coding the male connector with fixing brackets
Mounting example A max. cable entry ø 14 mm to the top, see page 20.23
Mounting example B max. cable entry ø 14 mm to the bottom, see page 20.23
3)
Fits D 20/2 and D 20/4
20
.
21
Shell housing D 20
Identification
Part No.
Drawing
Dimensions in mm
Mounting possibilities
for code comb
at the male connector
with fixing brackets
M 2.5 x 18
DIN EN ISO 1207
pcb
M 2.5
Fixing brackets B
for male connectors*
for 19” racks according
to DIN EN 60 297,
part 3-101
Single fixing*
left
09 06 000 9909
M 2.5
DIN EN ISO 4 036
Shell housing D 20
left
right
right
09 06 000 9910
without nut
left
09 06 001 9934
right
09 06 001 9935
M 2.5
DIN 562
Multiple fixing*
without coding
at the fixing bracket
without nut
Shell
housings
without coding
at the fixing bracket
with nut
M 2.5 DIN 562
left
09 06 000 9907
left
09 06 000 9966
with coding
at fixing bracket1)
with nut
M 2.5
15 mm
DIN 562
20 mm
left
09 06 000 9995
09 06 000 9997
15 mm
20 mm
right
09 06 000 9996
09 06 000 9998
fits female connectors
and I element crimp
20
.
22
left
M 2.5
DIN 562
Shell housing D 20
left
2)
supplied with fixing
09 06 001 9909
* Fits D 20/2 and D 20/4
Specific coding between the fixing bracket and the pcb guiding rail.
The guiding rail and corresponding coding pins are not scope of delivery
1)
right
right
09 06 000 9908
right
09 06 000 9967
Protection and fixing strip* for 20 mm
shell housing
Single fixing
Shell housing D 20
right
mounting examples
with nut
M 2.5 DIN 562
Shell housing D 20
Mounting examples
Dimensions in mm
Single fixing
Multiple fixing
or
Shell
housings
or
Mounting example A2)
max. cable entry to the top
Mounting example B
max. cable entry
to the bottom
Separate accessories
for housings
Fitting female connectors
1)
Specific coding between the fixing bracket and the pcb guiding rail
2)
Max. cable entry (ø 14 mm) from the bottom with fixing brackets 09 06 901 9924/…9925
possible. See page 20.29.
Fitting male connectors
Fixing brackets
Housing parts supplied
20
.
23
EMC housing
EMC with HARTING connectors
HARTING offers metallised D 20 housings and full
metal housings for EMC connectors according to
IEC 60 603-2. Its strong EMI characteristics and
metallised fixing elements offers optimal shielding
and grounding.
The connection of the cable braid to different types of
connector housings, as well as the influence of
the connector itself on EMC characteristics of an
instrument application, were analysed in regard to the
shielding effectiveness against electromagnetic
radiation. The shielded signal data lines of a railway
application were carried via two eurocard pcb´s
installed into a 19”-rack. The fixing of the cable braid
was realised with different HARTING D 20 housings.
The application including the connectors was then
exposed to RF signals, transient bursts and electrostatic
discharges.
Shell
housings
The standard plastic housings showed minimal EMC
performance. The EMC performance of metallised and
full metal housings showed significant improvements.
20
.
24
One advantage of metallised housings is their
reduced weight (40 grams compared to 180 grams of
a full metal housing). Therefore, minimal interference
is applied to the pcb in applications where strong
vibration is occuring. The HARTING housings are
comparatively light through the use of metallised
plastic.
The main advantages of a full metal housing are
improved cable braid fixing, easy mounting and
robustness.
In general, one should keep in mind that an unshielded
cable entry leads to loss of the shielding against
electromagnetic interference.
“A high-resistance interruption of the cable shield
(e.g. by using “pigtails” via twisted stranded
wires of the cable shield) may affect the EMC
performance and therefore cause unacceptable
effects to the electromagnetic environment.”
These housings are applied in electronic
installations of the railway vehicles of
the GERMAN RAILWAY. They are also
recommended for stationary installations of
the GERMAN RAILWAY (see norm BN 74016,
part 1 of December 1989).
Shell housing D 20 metallised for types F, H and MH
I
Identification
Part No.
Shell housing
D 20/2 metallised
II
Drawing
Dimensions in mm
Order inserts separately
with two side
cable entries
Blanking piece 2 x
I
20 mm
09 06 948 0521
Supplied with:
see page 20.18
Shell housing
D 20/4 metallised
with four side
cable entries
II
20 mm
09 06 948 0522
Shell
housings
Supplied with:
Shell 1x
Cover 1x
Locking screw 2x
Locking washer 2.3 2x
Screw KA 22x7.5 12x
Blinding piece 3x
Cable clamp 4x
Metallised insert
e. g. for LED*
for 55 mm height
09 06 900 9986
pcb
for 60 mm height
09 06 900 9987
pcb
Metallised
round cable insert*
2 x ø 11
* Fits D 20/2 metallised
09 06 900 9988
20
.
25
Shell housing D 20 metallised
I
II
Coding
Identification
Part No.
Drawing
Dimensions in mm
Metallised code comb
for shell housing3)
(can also be used as
blanking cover)
09 06 900 9984
I
Code pin3)
09 06 001 99051)
1)
Order 13 pieces per code comb
Order 13 pieces
per code comb
Metallised code comb
for male connector3)
II
09 06 900 9985
Shell
housings
Mounting possibilities
for the code comb
in shell housing D 20/2
metallised
2)
20
.
26
Use the lower slot
when coding the male connector with fixing brackets
Mounting example A max. cable entry ø 14 mm to the top, see page 20.23
Mounting example B max. cable entry ø 14 mm to the bottom, see page 20.23
3)
Fits D 20/2 and D 20/4 metallised
Shell housing D 20 metallised
Identification
Part No.
Drawing
Dimensions in mm
Mounting possibilities
for coding
at the male connector
with fixing brackets
M 2.5 x 18
DIN EN ISO 1207
pcb
M 2.5
Fixing brackets B
metallised
for male connectors*
without nut
with nut
M 2.5 DIN EN ISO
4 036
Multiple fixing*
without coding
at fixing bracket
without nut
without coding
at fixing bracket
with nut
M 2.5 DIN 562
left
09 06 900 9909
right
09 06 900 9910
left
09 06 901 9934
right
09 06 901 9935
left
M 2.5
DIN EN ISO 4 036
left
09 06 900 9907
right
09 06 900 9908
left
09 06 900 9966
right
09 06 900 9967
right
Shell housing D 20
left
right
M 2.5
DIN 562
Shell housing D 20
left
with coding
at fixing bracket1)
with nut
M 2.5 DIN 562
left
15 mm
09 06 900 9995
20 mm
09 06 900 9997
right
15 mm
09 06 900 9996
Protection and fixing*
strip for 20 mm shell
housing
Single fixing
fits female connectors
and I element crimp
2)
supplied with fixing
09 06 001 9909
* Fits D 20/2 and D 20/4 metallised
Specific coding between the fixing bracket and pcb guiding rail
1)
right
Shell
housings
Single fixing*
Shell housing D 20
mounting examples
for 19” racks according
to DIN EN 60 297,
part 3-101
M 2.5
DIN EN ISO 4 036
20
.
27
Shell housing D 20 metal for types F, H and MH
I
Identification
Part No.
Shell housing
D 20 metal
I
Supplied with:
Shell with coding
Cover
Locking screw
(hexagonal)
M2.5 x 22
Screw (torx)
M2.5 x 10
Earth screw
M4 x 8
1x
1x
2x
09 06 848 0550
4x
2x
Shell
housings
Shell housing
D 20 metal HF
with nickel-plated
surface
II
Supplied with:
Shell with coding
and HF-sealing spring
Cover
with shielding plate
Locking screw
(hexagonal)
M2.5 x 22
Screw (torx)
M2.5 x 10
Earth screw
M4 x 8
20
.
28
1x
1x
2x
4x
2x
09 06 848 0551
Drawing
II
Dimensions in mm
Shell housing D 20 metal HF for types F, H and MH
IV
I
V
VII
VI
II
Identification
Part No.
Drawing
Fixing brackets B
metallised
for male connectors
with nut
M 2.5
DIN EN ISO 4 036
Dimensions in mm
Shell housing D 20
for 19” racks according
to DIN EN 60 297,
part 3-101
Single fixing
VIII
III
left
I
left
20 mm
09 06 901 9924
II
right
20 mm
09 06 901 9925
right
M 2.5 DIN EN ISO 4 036
Multiple fixing
Shell housing D 20
with coding
at fixing bracket
with nut
M 2.5 DIN 562
III
left
20 mm
09 06 900 9997
IV
right
15 mm
09 06 900 9996
V
09 06 800 9951
VI
09 06 800 9955
VII
09 06 800 9950
VIII
09 06 001 9906
left
right
Shell
housings
Blinding piece
Cable clamp
Cable grommet
with strain relief
Code pin
Earth screw
09 06 800 9958
Order 13 pieces
per code comb
20
.
29
Electronic connectors in heavy duty housings
For applications where robust, high density, splash-proof
connectors are required, e.g. in the automated control and
industrial processing systems, HARTING have combined
the proven reliability of DIN 41 612 connectors with standard
Han® 24 B heavy duty hoods and housings, to bring forward a
connector system with up to 96 ways and various contact plating
thicknesses to suit the individual requirements.
Advantages
● The
combination enhances design flexibility, as it permits an
identical wiring interface between the standard 19“ racking
systems and the peripheral equipment.
●
Simplified stock-holding, identical operating tools.
Inserts
Female
2 x 48 way type F female connectors
with crimp contact elements
see chapter 02
Male
2 x 48 way type F interface connectors I
with crimp contact elements
see chapter 02
Hoods and housings
see catalogue "Heavy Duty Han® Connectors"
chapter 30
size 24 B
Degree of protection for hoods and housings: IP 65
Retaining frames
For fixing the inserts into the housing.
Alternative versions with pre-mating contacts and ground
termination.
Shell
housings
If the working voltages are in excess of 42 V (50 V) it is essential
to use retaining frames which have pre-mating ground contacts.
20
.
30
Retaining frames
II
Identification
Part No.
I
Drawing
Dimensions in mm
Retaining frame
without contact
elements
09 06 001 9904
I
Retaining frame with
2 contact pins and
ground termination
09 06 001 9902
Retaining frame with
2 contact sockets and
ground termination
09 06 001 9903
Each retaining frame is supplied with 4 fixing screws for mounting the inserts
and with 2 guide pins and sockets that provide mechanical protection for
the contacts during mating and disconnection. These can also be used as a
coding system to prevent cross plugging of adjacent connectors.
Mounting example
Shell
housings
II
Connectors in the retaining frame with contact sockets
Guide pin
Ground
termination
Contact socket
Guide sockets
M 2.5 x 6
DIN EN ISO
1207
20
.
31
Retaining frame for types C and R is available with part no. 09 03 000 9911
Shell
housings
Notes
20
.
32