DC Voltage Transducer
DIN RAIL / PANEL MOUNT, RMS
The CR5300 Series, DC Voltage Transducers and Transmitters,
are designed to provide an output DC signal that is
proportional to the input DC voltage. These devices are
especially suited for applications with a current shunt to
monitor DC current.
Applications
Power Supply over/under sensing
Battery chargers and systems
Mobile applications
Power sensing
CR5310
Features
CR5320
Output isolated from input
Available with 0-5 VDC, 0-10 VDC or 4 - 20 mADC outputs
35mm DIN rail or panel mount
Connection diagram printed on case
Single Element
0.1 - 600 VDC Input Range
C
Transducers
CR5311
Regulatory Agencies
If you need a relay output, use a CR3395.
See Section for Details.
Recognized to meet UL 61010B-1
Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004
Meets requirement of IEC 61010-1 and BS EN 61010-1
CR5310 with Resistor Application is
shown below (optional).
L1
E199795
L2
1
2
3
4
9
8
7
6
5
M
XXXX
+
-
Add suffix for input range
PART NUMBERS
CR5310
CR5311
CR5320
-
Single Element with ± 5 VDC output
Single Element with ± 10 VDC output
Single Element with 4 - 20 mADC output
NOTE: CR5300 Series is available with 12V Power Supply. Use same application as 24V Power Supply.
Example Part Number: CR5310-300-12V
The Professional
Energy Monitoring
Company
M N TI
ISO 9001:2008 Quality Management System
1
5
10
50
150
200
-
0-1 VDC
0-5 VDC
0-10 VDC
0-50 VDC
0-150 VDC
0-200 VDC
Ranges available up to and
including 1,000 VDC
* UL Recognized up to 300 Vdc
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
48
E-mail: sales@crmagnetics.com
DC Voltage Transducer
DIN RAIL / PANEL MOUNT, RMS
SPECIFICATIONS
Basic Accuracy:....................... 1.0 %
Linearity:................................... 10% to 100% FS
Thermal Drift:........................... 500 PPM/°C
Operating Temperature:........... 0°C to +50°C
Installation Category:............... CAT II
Isolation Voltage:....................... 2500KVRMS/1mA/1Sec
Vibration Tested To:................. IEC 60068-2-6,1995
Pollution Degree:..................... 2
Altitude:................................... 2000 meter max.
Response Time: .................... 250 ms. max.
Insulation Voltage:................... 2500 VDC
Cleaning:................................. Water-dampened cloth
Supply Voltage:............. 24 VDC ±10%
Frequency Range:........ DC only
Output Load:.................. 4-20 mADC - 0 to 300 Ω
0-5 VDC - 2K Ω or Greater
Relative Humidity:........ 5% to 95%, Non-Condensing
Supply Current:
CR5310:........................ Typical 35mA
Max 40mA
CR5320:........................ Typical 35mA
Max 40mA
Torque Specs.:.............. 3.0 inch lbs. (0.4Nm)
Weight:.......................... 0.5 lbs.
C
Top View
[3.3]
.13
Optional
Mounting
DIN RAIL
MOUNTING
CLIP
[73.1]
2.88
[83.3]
3.28
+
INPUT 1
-
1
2
3
4
+
9
8
7
6
5
OUTPUT 1
-
+ SUPPLY
CR5310 5 VDC Output
CR5311 10 VDC Output
[62.1]
2.45
[5.6]
.22
TYP
[88.7]
3.49
+
CR5310 CR5311 CR5320
INPUT 1
-
1
2
3
4
+
9
8
7
6
5
OUTPUT 1
+
-
-
SUPPLY
[30.4]
1.20
CR5320 4 - 20 mADC Output
[28.3]
1.12
End View
[36.6]
1.44
OUTLINE DRAWING
CONNECTION DIAGRAM
NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker
shall be marked as the disconnecting device for the equipment.
The Professional
Energy Monitoring
Company
M N TI
ISO 9001:2008 Quality Management System
3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119
Web: http://www.crmagnetics.com
49
E-mail: sales@crmagnetics.com
Transducers
[26.6]
1.05
很抱歉,暂时无法提供与“CR5311-0.1”相匹配的价格&库存,您可以联系我们找货
免费人工找货