CR6211-250-50

CR6211-250-50

  • 厂商:

    CR

  • 封装:

    -

  • 描述:

    TRANSDCR AC 0-5 VDC OUT 1PHASE

  • 详情介绍
  • 数据手册
  • 价格&库存
CR6211-250-50 数据手册
AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE The CR6200 Series, Power Transducers and Transmitters are designed to provide a controlled output that is proportional to the average power. These devices are specifically targeted to provide an efficient solution to most power sensing needs. Units are designed for operation in systems with sinusoidal voltage and current wave forms. Applications Energy Management Motor Efficiency Multi-point power sensing Remote power sensing over long distances CR6210 CR6211 CR6220 CR6221 Features 35mm DIN Rail or Panel Mount Ranges available for any power sensing need Active and Reactive power sensing 0 - 5 VDC and 4 - 20 mADC outputs Connection diagram printed on case Transducers C Regulatory Agencies Recognized to meet UL 61010B-1 Constructed to meet CAN/CSA-C22.2, No. 61010-1-2004 Meets requirement of IEC 61010-1 and BS EN 61010-1 CR6230 CR6231 CR6240 CR6241 E199795 CR6250 CR6251 CR6260 CR6261 V CR Magnetics has a wide selection of Current and Potential Transformers to extend the range of any part. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System I - ACTIVE POWER - REACTIVE POWER POWER TRANSDUCERS CAN BE ORDERED TO MEASURE ACTIVE OR REACTIVE POWER 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 52 E-mail: sales@crmagnetics.com AC Power Transducer DIN RAIL / PANEL MOUNT, ACTIVE / REACTIVE Add suffix for input range - PART NUMBERS - CR6210 CR6211 CR6220 CR6221 CR6230 CR6231 CR6240 CR6241 CR6250 CR6251 CR6260 CR6261 - 1 Phase, Active Power with 0 - 5 VDC Output 1 Phase, Reactive Power with 0 - 5 VDC Output 1 Phase, Active Power with 4 - 20 mADC Output 1 Phase, Reactive Power with 4 - 20 mADC Output 2-Phase, 3-Wire, Active Power with 0 - 5 VDC Output 2-Phase, 3-Wire, Reactive Power with 0 - 5 VDC Output 2-Phase, 3-Wire, Active Power with 4 - 20 mADC Output 2-Phase, 3-Wire, Reactive Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Active Power with 0 - 5 VDC Output 3-Phase, 4-Wire, Reactive Power with 0 - 5 VDC Output 3-Phase, 4-Wire, Active Power with 4 - 20 mADC Output 3-Phase, 4-Wire, Reactive Power with 4 - 20 mADC Output SPECIFICATIONS [26.6] 1.05 Custom ranges available * not UL recognized 5 25 - 0-5 AAC 0-25 AAC CR Magnetics has a wide selection of current and potential transformers to extend the range of any part. Cleaning:................. Water-dampened cloth Relative Humidity:... 5% to 95%, Non-Condensing Supply Current: CR6210:......................Typical 35mA Max 45mA CR6220: Typical 75mA Max 110mA CR6230:......................Typical 50mA Max 70mA CR6240: Typical 75mA Max 110mA CR6250:......................Typical 50mA Max 70mA CR6260: Typical 75mA Max 120mA Torque Specs.:.............3.0 inch lbs. (0.4Nm) Weight:.........................0.5 lbs. DIN RAIL MOUNTING CLIP [25] .98 [62] 2.44 End View [31] 1.22 [6.6] .26 [6.6] .26 [73.1][83.3] 2.88 3.28 [64] 2.52 [3.3] .13 Optional Mounting [35] 1.38 [13.5] .53 [76.7] 3.02 [5.6] .22 TYP Top View 0-150 VAC 0-250 VAC 0-500 VAC * - [64] [76.7] 2.52 3.02 [5.6] .22 TYP [6.6] .260 [62] 2.44 [30.8] 1.21 [19.8] [19.8] .78 .78 [76.7] [64.2] 3.02 2.53 [28.3] 1.12 [88.7] 3.49 CR6210 CR6211 CR6220 CR6221 CR6230 CR6231 CR6240 CR6241 CR6250 CR6251 CR6260 CR6261 [36.6] 1.44 OUTLINE DRAWING NOTE: The building installation must have a switch or circuit-breaker that is in close proximity and within easy reach of the operator. The switch or circuit breaker shall be marked as the disconnecting device for the equipment. The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 53 E-mail: sales@crmagnetics.com C Transducers Basic Accuracy:......................... 0.5% Linearity:................................... 10% to 100% FS Thermal Drift:............................ 500 PPM/°C Operating Temperature:............ 0°C to +60°C Installation Category:................. CAT II Vibration Tested To:................... IEC 60068-2-6,1995 Pollution Degree:........................2 Response Time: ....................... 250 ms max. 0-90% FS Supply Voltage:......................... 12 to 24 VDC MTBF:.......................................Greater than 100 K hours Frequency Range:....................50 Hz - 400 Hz, sine wave Insulation Voltage:.................... 2500 VDC Altitude:.................................... 2000 meter max.Output Load:........................................ 4-20 mADC -0 to 300 Ω 0-5 VDC - 2K Ω or Greater 150 250 500 AC Power Transducer DIN RAIL / PANEL MOUNT, AVERAGE SENSING N L1 N L1 1 2 3 4 7 6 5 + - - + 1 2 3 4 OUTPUT 1 9 8 9 8 OUTPUT 1 7 6 - + 5 SUPPLY Supply LOAD LOAD CR6210 CR6211 Single element, 0 - 5 VDC Output CR6220 CR6221 Single element, 4 - 20 mADC Output N N 1 2 3 4 L1 1 2 3 4 9 8 7 6 5 OUTPUT 1 + - OUTPUT 1 C L1 L2 SUPPLY CR6220 CR6221 Single element, 4 - 20 mADC Output with external voltage transformers L3 1 2 1 OUTPUT 1 8 7 + - 6 5 L3 L1 L2 9 3 4 2 9 3 4 8 7 6 + - OUTPUT 1 + - 5 SUPPLY LOAD SUPPLY LOAD CR6230 CR6231 2 element - 3 Wire, 0 - 5 VDC Output CR6240 CR6241 2 element - 3 Wire, 4 - 20 mADC output L1 L3 L2 L3 L2 + 1 1 2 3 4 OUTPUT 1 9 8 7 6 5 2 9 3 4 8 7 - + OUTPUT 1 + - 6 5 SUPPLY SUPPLY LOAD LOAD CR6230 CR6231 2 element - 3 Wire, 0 - 5 VDC Output shown with external voltage and current transformers CR6240 CR6241 2 element - 3 Wire, 4 - 20 mADC Output shown with external current transformer L1 L1 L2 - + - LOAD CR6210 CR6211 Single element, 0 - 5 VDC Output with external voltage transformers L1 + 9 8 7 6 5 SUPPLY LOAD Transducers L1 L3 L2 L3 N N 1 2 3 4 9 8 7 6 5 1 2 3 4 OUTPUT 1 + SUPPLY + 9 8 7 6 5 OUTPUT 1 + - SUPPLY LOAD LOAD CR6250 CR6251 3 element - 4 Wire, 0 - 5 VDC Output shown with external voltage and current transformers CR6260 CR6261 3 element - 4 Wire, 4 - 20 mADC Output shown with external current transformers CONNECTION DIAGRAMS The Professional Energy Monitoring Company M N TI ISO 9001:2008 Quality Management System 3500 Scarlet Oak Blvd. St. Louis MO USA 63122 V: 636-343-8518 F: 636-343-5119 Web: http://www.crmagnetics.com 54 E-mail: sales@crmagnetics.com
CR6211-250-50
物料型号: - CR6210: 单相,有功功率,0 - 5 VDC输出 - CR6211: 单相,无功功率,0 - 5 VDC输出 - CR6220: 单相,有功功率,4 - 20 mADC输出 - CR6221: 单相,无功功率,4 - 20 mADC输出 - CR6230: 两相三线,有功功率,0 - 5 VDC输出 - CR6231: 两相三线,无功功率,0 - 5 VDC输出 - CR6240: 两相三线,有功功率,4 - 20 mADC输出 - CR6241: 两相三线,无功功率,4 - 20 mADC输出 - CR6250: 三相四线,有功功率,0 - 5 VDC输出 - CR6260: 三相四线,有功功率,4 - 20 mADC输出 - CR6261: 三相四线,无功功率,4 - 20 mADC输出

器件简介: CR6200系列功率变送器和变送器专为提供与平均功率成比例的控制输出而设计,适用于正弦波电压和电流波形的系统。

引脚分配封装信息: 文档中提供了不同型号的端视图和顶视图,展示了引脚分配和封装尺寸。

参数特性: - 基本精度:0.5% - 线性度:10%至100% FS - 热漂移:500 PPM/°C - 工作温度:0°C至+60°C - 响应时间:最大250毫秒(0-90% FS) - 供电电压:12至24 VDC - 频率范围:50 Hz至400 Hz,正弦波

功能详解: 这些设备可用于能源管理、电机效率、多点功率检测和远程功率检测。

应用信息: 适用于能源管理、电机效率、多点功率检测和远程功率检测。

封装信息: 提供了DIN导轨安装夹的尺寸信息。