Bridgelux Gen 7 Vero 29 Array
®
®
Product Data Sheet DS93
1
Vero® Series
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing
unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color
points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Features
• Efficacy of 160 lm/W typical
• Lumen output performance ranges from 3,850 to
38,400 lumens
• Broad range of CCT options from 1750K to 6500K
• CRI options include minimum 65, 70, 80, and 90, 2
and 3 SDCM color control for 2700K-4000K CCT
Benefits
• Broad application coverage for interior and exterior
lighting
• Flexibility for application driven lighting design
requirements
• High quality true color reproduction
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Thermally isolated solder pads
• Solderless connectivity enables plug & play
installation and field upgradability
• Onboard connector port
• Top side part number markings
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
20
Eye Safety
21
Absolute Maximum Ratings
22
Performance Curves
23
Typical Radiation Pattern
27
Typical Color Spectrum
28
Mechanical Dimensions
29
Color Binning Information
30
Packaging and Labeling
31
Design Resources
33
Precautions
33
Disclaimers
33
About Bridgelux
34
1
Product Feature Map
Vero 29 is the largest form factor in the Vero family of
next generation solid state light sources. In addition to
delivering the performance and light quality required
for many lighting applications, Vero incorporates several
features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
Mounting holes
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
2D Bar code provides full
manufacturing traceability
Top side part number marking improves
inventory management and outgoing
quality control
Radial die configuration improves lumen
density and beam control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRC – 30 E 10K 0 – C – 7 3
CCT Bin Options
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Gen. 7
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
Flux Indicator
10Kx = 10,000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74
1750
80
1800
8330
7497
52.0
93.6
89
BXRC-17E10K0-C-74
1750
80
1710
10562
9506
69.4
118.7
89
BXRC-17E10K0-D-74
1750
80
2100
7027
6325
37.6
79.0
89
BXRC-20B10K0-C-73
2000
65
1710
17724
15952
69.4
118.7
149
BXRC-20B10K0-D-73
2000
65
2100
11793
10613
37.6
79.0
149
BXRC-25E10K0-B-74
2500
80
1800
13401
12061
52.0
93.6
143
BXRC-25E10K0-C-74
2500
80
1710
16991
15292
69.4
118.7
143
BXRC-25E10K0-D-74
2500
80
2100
11305
10174
37.6
79.0
143
BXRC-27E10K0-B-7X
2700
80
1800
14365
12928
52.0
93.6
153
BXRC-27E10K0-C-7X
2700
80
1710
18213
16392
69.4
118.7
153
BXRC-27E10K0-D-7X
2700
80
2100
12118
10906
37.6
79.0
153
BXRC-27G1KH0-B-7X
2700
90
1800
12449
11204
52.0
93.6
133
BXRC-27G1KH0-C-7X
2700
90
1710
15784
14205
69.4
118.7
133
BXRC-27G1KH0-D-7X
2700
90
2100
10502
9452
37.6
79.0
133
BXRC-27G10K0-B-7X
2700
90
1800
11981
10783
52.0
93.6
128
BXRC-27G10K0-C-7X
2700
90
1710
15190
13671
69.4
118.7
128
2700
90
2100
10107
9096
37.6
79.0
128
BXRC-27H10K0-D-74
2700
97
2100
8788
7909
37.6
79.0
111
BXRC-30C10K1-B-74
3000
70
1800
16474
14826
52.0
93.6
176
BXRC-30C10K1-C-74
3000
70
1710
20887
18798
69.4
118.7
176
BXRC-27G10K0-D-7X
8,9
BXRC-30C10K1-D-74
3000
70
2100
13897
12507
37.6
79.0
176
BXRC-30E10K0-B-7X10
3000
80
1800
14976
13478
52.0
93.6
160
BXRC-30E10K0-C-7X10
3000
80
1710
18988
17089
69.4
118.7
160
BXRC-30E10K0-D-7X10
3000
80
2100
12634
11370
37.6
79.0
160
BXRC-30G1KH0-B-7X
3000
90
1800
13010
11709
52.0
93.6
139
BXRC-30G1KH0-C-7X
3000
90
1710
16496
14846
69.4
118.7
139
BXRC-30G1KH0-D-7X
3000
90
2100
10975
9878
37.6
79.0
139
BXRC-30G10K0-B-7X
3000
90
1800
12437
11193
52.0
93.6
133
BXRC-30G10K0-C-7X
3000
90
1710
15768
14191
69.4
118.7
133
BXRC-30G10K0-D-7X
3000
90
2100
10491
9442
37.6
79.0
133
BXRC-30H10K0-D-7X
3000
97
2100
9353
8418
37.6
79.0
118
BXRC-30A10K1-B-738,9
3000
93
1800
11232
10109
52.0
93.6
120
BXRC-30A10K1-C-738,9
3000
93
1710
14241
12817
69.4
118.7
120
BXRC-30A10K1-D-738,9
3000
93
2100
9475
8528
37.6
79.0
120
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80
CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on
CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7X10
3500
80
1800
15444
13900
52.0
93.6
165
BXRC-35E10K0-C-7X10
3500
80
1710
19581
17623
69.4
118.7
165
BXRC-35E10K0-D-7X10
3500
80
2100
13028
11726
37.6
79.0
165
BXRC-35G10K0-B-7X
3500
90
1800
12822
11540
52.0
93.6
137
BXRC-35G10K0-C-7X
3500
90
1710
16257
14631
69.4
118.7
137
BXRC-35G10K0-D-7X
3500
90
2100
10817
9735
37.6
79.0
137
BXRC-35A10K1-B-738,9
3500
93
1800
12074
10867
52.0
93.6
129
BXRC-35A10K1-C-738,9
3500
93
1710
15309
13778
69.4
118.7
129
BXRC-35A10K1-D-738,9
3500
93
2100
10186
9167
37.6
79.0
129
BXRC-40C10K1-B-74
4000
70
1800
16871
15184
52.0
93.6
180
BXRC-40C10K1-C-74
4000
70
1710
21391
19252
69.4
118.7
180
BXRC-40C10K1-D-74
4000
70
2100
14233
12809
37.6
79.0
180
BXRC-40E10K0-B-7X10
4000
80
1800
15538
13984
52.0
93.6
166
BXRC-40E10K0-C-7X10
4000
80
1710
19700
17730
69.4
118.7
166
BXRC-40E10K0-D-7X10
4000
80
2100
13107
11797
37.6
79.0
166
BXRC-40G10K0-B-7X
4000
90
1800
13304
11974
52.0
93.6
142
10
BXRC-40G10K0-C-7X
4000
90
1710
16868
15181
69.4
118.7
142
BXRC-40G10K0-D-7X
4000
90
2100
11223
10101
37.6
79.0
142
BXRC-40H10K0-D-73
4000
97
2100
9633
8670
37.6
79.0
122
BXRC-40A10K1-B-738,9
4000
93
1800
12917
11625
52.0
93.6
138
BXRC-40A10K1-C-738,9
4000
93
1710
16377
14739
69.4
118.7
138
BXRC-40A10K1-D-738,9
4000
93
2100
10896
9807
37.6
79.0
138
BXRC-50C10K1-B-7410
5000
70
1800
17064
15358
52.0
93.6
182
BXRC-50C10K1-C-7410
5000
70
1710
21635
19472
69.4
118.7
182
BXRC-50C10K1-D-7410
5000
70
2100
14395
12956
37.6
79.0
182
BXRC-50E10K1-B-74
5000
80
1800
16004
14403
52.0
93.6
171
BXRC-50E10K1-C-74
5000
80
1710
20291
18262
69.4
118.7
171
BXRC-50E10K1-D-74
5000
80
2100
13501
12151
37.6
79.0
171
BXRC-50G10K1-B-74
5000
90
1800
13594
12234
52.0
93.6
145
BXRC-50G10K1-C-74
5000
90
1710
17235
15512
69.4
118.7
145
BXRC-50G10K1-D-74
5000
90
2100
11467
10321
37.6
79.0
145
BXRC-56G10K0-B-74
5600
90
1800
14268
12842
52.0
93.6
152
BXRC-56G10K0-C-74
5600
90
1710
18091
16282
69.4
118.7
152
BXRC-56G10K0-D-74
5600
90
2100
12037
10833
37.6
79.0
152
BXRC-56H10K1-D-74
5600
97
2100
10410
9369
37.6
79.0
132
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI
products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and
R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C10K1-B-7410
5700
70
1800
16486
14837
52.0
93.6
176
BXRC-57C10K1-C-7410
5700
70
1710
20902
18812
69.4
118.7
176
BXRC-57C10K1-D-7410
5700
70
2100
13907
12517
37.6
79.0
176
BXRC-57E10K1-B-7410
5700
80
1800
15818
14237
52.0
93.6
169
BXRC-57E10K1-C-7410
5700
80
1710
20056
18050
69.4
118.7
169
BXRC-57E10K1-D-7410
5700
80
2100
13344
12010
37.6
79.0
169
BXRC-65C10K1-B-7410
6500
70
1800
16775
15097
52.0
93.6
179
BXRC-65C10K1-C-7410
6500
70
1710
21269
19142
69.4
118.7
179
BXRC-65C10K1-D-7410
6500
70
2100
14151
12736
37.6
79.0
179
BXRC-65E10K1-B-7410
6500
80
1800
16099
14489
52.0
93.6
172
BXRC-65E10K1-C-7410
6500
80
1710
20412
18371
69.4
118.7
172
BXRC-65E10K1-D-7410
6500
80
2100
13581
12223
37.6
79.0
172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A and Décor Series Ultra products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI
products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and
R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A10K1-B-73
3000
80
93
1800
10446
9401
50.9
91.6
114
BXRC-30A10K1-C-73
3000
80
93
1710
13244
11920
67.9
116.1
114
BXRC-30A10K1-D-73
3000
80
93
2100
8812
7931
36.8
77.3
114
BXRC-35A10K1-B-73
3500
80
93
1800
11229
10106
50.9
91.6
123
BXRC-35A10K1-C-73
3500
80
93
1710
14237
12814
67.9
116.1
123
BXRC-35A10K1-D-73
3500
80
93
2100
9473
8526
36.8
77.3
122
BXRC-40A10K1-B-73
4000
80
93
1800
12013
10811
50.9
91.6
131
BXRC-40A10K1-C-73
4000
80
93
1710
15231
13708
67.9
116.1
131
BXRC-40A10K1-D-73
4000
80
93
2100
10134
9120
36.8
77.3
131
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E10K0-B-74
1750
80
1800
7497
6748
50.7
91.2
82
BXRC-17E10K0-C-74
1750
80
1710
9506
8555
68.1
116.4
82
BXRC-17E10K0-D-74
1750
80
2100
6325
5692
36.6
76.8
82
BXRC-20B10K0-C-73
2000
65
1710
15952
14356
68.1
116.4
137
BXRC-20B10K0-D-73
2000
65
2100
10613
9552
36.6
76.8
138
BXRC-25E10K0-B-74
2500
80
1800
12061
10855
50.7
91.2
132
BXRC-25E10K0-C-74
2500
80
1710
15292
13762
68.1
116.4
131
BXRC-25E10K0-D-74
2500
80
2100
10174
9157
36.6
76.8
133
BXRC-27E10K0-B-7X
2700
80
1800
12928
11635
50.7
91.2
142
BXRC-27E10K0-C-7X
2700
80
1710
16392
14752
68.1
116.4
141
BXRC-27E10K0-D-7X
2700
80
2100
10906
9816
36.6
76.8
142
BXRC-27G1KH0-B-7X
2700
90
1800
11204
10084
51.0
91.7
122
BXRC-27G1KH0-C-7X
2700
90
1710
14205
12785
68.4
116.9
122
BXRC-27G1KH0-D-7X
2700
90
2100
9452
8506
36.6
76.8
123
BXRC-27G10K0-B-7X
2700
90
1800
10783
9704
51.0
91.7
118
BXRC-27G10K0-C-7X
2700
90
1710
13671
12304
68.4
116.9
117
BXRC-27G10K0-D-7X
2700
90
2100
9096
8187
36.6
76.8
118
BXRC-27H10K0-D-74
2700
97
2100
7909
7118
36.6
76.8
103
BXRC-30C10K1-B-74
3000
70
1800
14826
13344
51.0
91.7
162
BXRC-30C10K1-C-74
3000
70
1710
18798
16918
68.4
116.9
161
BXRC-30C10K1-D-74
3000
70
2100
12507
11257
36.6
76.8
163
BXRC-30E10K0-B-7X
3000
80
1800
13478
12131
51.0
91.7
147
BXRC-30E10K0-C-7X
3000
80
1710
17089
15380
68.4
116.9
146
BXRC-30E10K0-D-7X
3000
80
2100
11370
10233
36.6
76.8
148
BXRC-30G1KH0-B-7X
3000
90
1800
11709
10538
51.0
91.7
128
BXRC-30G1KH0-C-7X
3000
90
1710
14846
13362
68.4
116.9
127
BXRC-30G1KH0-D-7X
3000
90
2100
9878
8890
36.6
76.8
129
BXRC-30G10K0-B-7X
3000
90
1800
11193
10074
50.7
91.2
123
BXRC-30G10K0-C-7X
3000
90
1710
14191
12772
68.1
116.4
122
BXRC-30G10K0-D-7X
3000
90
2100
9442
8498
36.6
76.8
123
BXRC-30H10K0-D-7X
3000
97
2100
8418
7576
36.6
76.9
110
BXRC-30A10K1-B-737,8
3000
93
1800
10109
9098
50.7
91.2
111
BXRC-30A10K1-C-737,8
3000
93
1710
12817
11535
68.1
116.4
110
BXRC-30A10K1-D-737,8
3000
93
2100
8528
7675
36.6
76.8
111
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A and Décor Series Ultra products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7X
3500
80
1800
13900
12510
50.7
91.2
152
BXRC-35E10K0-C-7X
3500
80
1710
17623
15861
68.1
116.4
151
BXRC-35E10K0-D-7X
3500
80
2100
11726
10553
36.6
76.8
153
BXRC-35G10K0-B-7X
3500
90
1800
11540
10386
50.7
91.2
127
BXRC-35G10K0-C-7X
3500
90
1710
14631
13168
68.1
116.4
126
BXRC-35G10K0-D-7X
3500
90
2100
9735
8762
36.6
76.8
127
BXRC-35A10K1-B-737,8
3500
93
1800
10867
9780
50.7
91.2
119
BXRC-35A10K1-C-737,8
3500
93
1710
13778
12400
68.1
116.4
118
BXRC-35A10K1-D-737,8
3500
93
2100
9167
8251
36.6
76.8
119
BXRC-40C10K1-B-74
4000
70
1800
15184
13666
51.0
91.7
166
BXRC-40C10K1-C-74
4000
70
1710
19252
17327
68.4
116.9
165
BXRC-40C10K1-D-74
4000
70
2100
12809
11528
36.6
76.8
167
BXRC-40E10K0-B-7X
4000
80
1800
13984
12585
50.7
91.2
153
BXRC-40E10K0-C-7X
4000
80
1710
17730
15957
68.1
116.4
152
BXRC-40E10K0-D-7X
4000
80
2100
11797
10617
36.6
76.8
154
BXRC-40G10K0-B-7X
4000
90
1800
11974
10776
50.7
91.2
131
BXRC-40G10K0-C-7X
4000
90
1710
15181
13663
68.1
116.4
130
BXRC-40G10K0-D-7X
4000
90
2100
10101
9091
36.6
76.8
132
BXRC-40H10K0-D-73
4000
97
2100
8670
7803
36.6
76.9
113
BXRC-40A10K1-B-737,8
4000
93
1800
11625
10463
50.7
91.2
127
BXRC-40A10K1-C-737,8
4000
93
1710
14739
13265
68.1
116.4
127
BXRC-40A10K1-D-737,8
4000
93
2100
9807
8826
36.6
76.8
128
BXRC-50C10K1-B-74
5000
70
1800
15358
13822
50.7
91.2
168
BXRC-50C10K1-C-74
5000
70
1710
19472
17525
68.1
116.4
167
BXRC-50C10K1-D-74
5000
70
2100
12956
11660
36.6
76.8
169
BXRC-50E10K1-B-74
5000
80
1800
14403
12963
50.7
91.2
158
BXRC-50E10K1-C-74
5000
80
1710
18262
16436
68.1
116.4
157
BXRC-50E10K1-D-74
5000
80
2100
12151
10935
36.6
76.8
158
BXRC-50G10K1-B-74
5000
90
1800
12234
11011
50.7
91.2
134
BXRC-50G10K1-C-74
5000
90
1710
15512
13960
68.1
116.4
133
BXRC-50G10K1-D-74
5000
90
2100
10321
9289
36.6
76.8
134
BXRC-56G10K0-B-74
5600
90
1800
12842
11557
50.7
91.2
141
BXRC-56G10K0-C-74
5600
90
1710
16282
14653
68.1
116.4
140
BXRC-56G10K0-D-74
5600
90
2100
10833
9750
36.6
76.8
141
BXRC-56H10K1-D-74
5600
97
2100
9369
8432
36.6
76.9
122
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Class A and Décor Series Ultra products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C10K1-B-74
5700
70
1800
14837
13353
50.7
91.2
163
BXRC-57C10K1-C-74
5700
70
1710
18812
16931
68.1
116.4
162
BXRC-57C10K1-D-74
5700
70
2100
12517
11265
36.6
76.8
163
BXRC-57E10K1-B-74
5700
80
1800
14237
12813
50.7
91.2
156
BXRC-57E10K1-C-74
5700
80
1710
18050
16245
68.1
116.4
155
BXRC-57E10K1-D-74
5700
80
2100
12010
10809
36.6
76.8
156
BXRC-65C10K1-B-74
6500
70
1800
15097
13588
50.7
91.2
166
BXRC-65C10K1-C-74
6500
70
1710
19142
17228
68.1
116.4
164
BXRC-65C10K1-D-74
6500
70
2100
12736
11462
36.6
76.8
166
BXRC-65E10K1-B-74
6500
80
1800
14489
13040
50.7
91.2
159
BXRC-65E10K1-C-74
6500
80
1710
18371
16534
68.1
116.4
158
BXRC-65E10K1-D-74
6500
80
2100
12223
11001
36.6
76.8
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A and Décor Series Ultra products. CRI values are minimums
for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E10K0-B-74
80
BXRC-17E10K0-C-74
80
BXRC-17E10K0-D-74
80
BXRC-20B10K0-C-73
65
BXRC-20B10K0-D-73
65
BXRC-25E10K0-B-74
80
BXRC-25E10K0-C-74
80
BXRC-25E10K0-D-74
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
4325
5694
8330
12008
15369
6000
7626
10562
14983
18780
3865
4975
7027
10005
12609
10068
12797
17724
25144
31515
6487
8348
11793
16789
21160
6957
9160
13401
19317
24724
9652
12267
16991
24103
30211
6218
8003
11305
16094
20284
3948
5176
7497
10709
13541
5709
7034
9506
12887
15781
3766
4630
6325
8430
10297
9581
11804
15952
21625
26482
6320
7769
10613
14146
17279
6350
8326
12061
17227
21783
9185
11316
15292
20731
25386
6059
7448
10174
13561
16564
97
94
89
82
76
106
99
89
81
74
104
98
89
80
73
178
167
149
136
124
175
165
149
135
122
156
151
143
132
123
171
160
143
130
119
167
158
143
129
117
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E10K0-B-7X
80
BXRC-27E10K0-C-7X
80
BXRC-27E10K0-D-7X
80
BXRC-27G1KH0-B-7X
90
BXRC-27G1KH0-C-7X
90
BXRC-27G1KH0-D-7X
90
BXRC-27G10K0-B-7X
90
BXRC-27G10K0-C-7X
90
BXRC-27G10K0-D-7X
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
7457
9819
14365
20707
26502
10346
13150
18213
25837
32385
6666
8578
12118
17252
21743
6462
8509
12449
17945
22967
8966
11396
15784
22391
28065
5776
7434
10502
14951
18843
6220
8189
11981
17270
22104
8629
10968
15190
21549
27010
5559
7155
10107
14389
18135
6807
8925
12928
18466
23350
9845
12130
16392
22222
27212
6495
7983
10906
14536
17755
5899
7735
11204
16003
20236
8532
10512
14205
19258
23582
5628
6919
9452
12597
15387
5677
7444
10783
15402
19475
8211
10117
13671
18534
22696
5417
6658
9096
12124
14809
167
162
153
142
132
183
171
153
140
127
179
169
153
139
126
145
141
133
123
114
158
149
133
121
110
155
147
133
120
109
139
135
128
118
110
153
143
128
116
106
149
141
128
116
105
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27H10K0-D-74
97
BXRC-30C10K1-B-74
70
BXRC-30C10K1-C-74
70
BXRC-30C10K1-D-74
70
BXRC-30E10K0-B-7X
80
BXRC-30E10K0-C-7X
80
BXRC-30E10K0-D-7X
80
BXRC-30G1KH0-B-7X
90
BXRC-30G1KH0-C-7X
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
4834
6221
8788
12511
15768
9358
11894
16474
23370
29292
11489
14786
20887
29735
37477
7644
9838
13897
19784
24935
7774
10237
14976
21588
27630
10786
13709
18988
26937
33762
6949
8943
12634
17986
22668
6754
8893
13010
18754
24003
9371
11910
16496
23401
29331
4710
5790
7909
10542
12876
8905
10972
14826
20100
24613
11194
13760
18798
25055
30603
7448
9155
12507
16670
20362
7097
9305
13478
19252
24344
10264
12646
17089
23168
28370
6771
8323
11370
15155
18511
6165
8084
11709
16725
21149
8917
10986
14846
20127
24646
130
123
111
101
91
210
196
176
160
146
203
193
176
161
147
205
194
176
159
144
174
169
160
148
137
191
179
160
146
133
187
177
160
145
131
151
147
139
128
119
166
155
139
127
115
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G1KH0-D-7X
90
BXRC-30G10K0-B-7X
90
BXRC-30G10K0-C-7X
90
BXRC-30G10K0-D-7X
90
BXRC-30H10K0-D-7X
97
BXRC-30A10K1-B-73
93
BXRC-30A10K1-C-73
93
BXRC-30A10K1-D-73
93
BXRC-35E10K0-B-7X
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
6037
7770
10975
15625
19693
6456
8501
12437
17927
22945
8957
11385
15768
22369
28038
5771
7427
10491
14936
18825
5145
6621
9353
13315
16782
5831
7678
11232
16191
20722
8090
10282
14241
20202
25322
5212
6707
9475
13489
17001
8017
10557
15444
22262
28493
5882
7231
9878
13166
16081
5893
7727
11193
15988
20216
8524
10502
14191
19239
23559
5623
6912
9442
12585
15372
5013
6162
8418
11219
13704
5322
6979
10109
14439
18258
7698
9485
12817
17376
21277
5078
6242
8528
11366
13883
7318
9596
13900
19854
25105
162
153
139
126
114
145
140
133
123
114
158
148
133
121
110
155
147
133
120
109
138
131
118
107
97
131
127
120
111
103
143
134
120
109
99
140
132
120
108
98
179
174
165
152
142
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35E10K0-C-7X
80
BXRC-35E10K0-D-7X
80
BXRC-35G10K0-B-7X
90
BXRC-35G10K0-C-7X
90
BXRC-35G10K0-D-7X
90
BXRC-35A10K1-B-73
93
BXRC-35A10K1-C-73
93
BXRC-35A10K1-D-73
93
BXRC-40C10K1-B-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
11123
14138
19581
27778
34818
7166
9223
13028
18548
23377
6656
8765
12822
18483
23656
9235
11738
16257
23063
28907
5950
7657
10817
15399
19408
6268
8253
12074
17405
22277
8697
11053
15309
21718
27221
5603
7211
10186
14501
18276
8758
11532
16871
24320
31127
10585
13041
17623
23891
29256
6983
8583
11726
15628
19089
6076
7967
11540
16484
20843
8788
10827
14631
19836
24290
5797
7126
9735
12975
15849
5722
7502
10867
15522
19627
8276
10196
13778
18679
22873
5459
6710
9167
12218
14924
7995
10483
15184
21689
27425
197
184
165
150
137
193
182
165
149
135
149
145
137
127
118
163
153
137
125
114
160
151
137
124
112
140
136
129
119
111
154
144
129
117
107
151
142
129
117
106
196
190
180
167
155
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C10K1-C-74
70
BXRC-40C10K1-D-74
70
BXRC-40E10K0-B-7X
80
BXRC-40E10K0-C-7X
80
BXRC-40E10K0-D-7X
80
BXRC-40G10K0-B-7X
90
BXRC-40G10K0-C-7X
90
BXRC-40G10K0-D-7X
90
BXRC-40H10K0-D-73
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
12152
15445
21391
30346
38035
7829
10075
14233
20262
25537
8066
10621
15538
22397
28666
11191
14224
19700
27947
35029
7210
9279
13107
18660
23519
6907
9094
13304
19178
24546
9582
12179
16868
23930
29994
6173
7945
11223
15978
20138
5299
6819
9633
13714
17285
11563
14247
19252
26100
31960
7628
9376
12809
17073
20854
7363
9654
13984
19974
25257
10649
13120
17730
24036
29434
7025
8635
11797
15723
19205
6304
8266
11974
17103
21626
9118
11235
15181
20581
25203
6015
7394
10101
13463
16444
5163
6346
8670
11555
14114
215
201
180
164
149
210
199
180
163
148
181
175
166
153
143
198
185
166
151
138
194
183
166
150
136
155
150
142
131
122
169
159
142
129
118
166
157
142
128
116
142
135
122
110
100
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A10K1-B-73
93
BXRC-40A10K1-C-73
93
BXRC-40A10K1-D-73
93
BXRC-50C10K1-B-74
70
BXRC-50C10K1-C-74
70
BXRC-50C10K1-D-74
70
BXRC-50E10K1-B-74
80
BXRC-50E10K1-C-74
80
BXRC-50E10K1-D-74
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
6705
8829
12917
18619
23831
9303
11824
16377
23233
29120
5994
7714
10896
15513
19552
8858
11664
17064
24598
31482
12290
15621
21635
30693
38470
7918
10190
14395
20494
25829
8308
10939
16004
23069
29526
11527
14650
20291
28785
36079
7426
9557
13501
19220
24224
6121
8026
11625
16605
20997
8853
10907
14739
19982
24469
5840
7179
9807
13071
15966
8086
10603
15358
21937
27738
11695
14409
19472
26398
32326
7715
9484
12956
17268
21092
7584
9944
14403
20573
26014
10969
13514
18262
24757
30317
7236
8894
12151
16195
19781
150
146
138
127
119
164
154
138
126
114
161
152
138
125
113
198
193
182
168
157
217
204
182
166
151
213
201
182
165
149
186
181
171
158
147
204
191
171
156
142
200
189
171
155
140
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G10K1-B-74
90
BXRC-50G10K1-C-74
90
BXRC-50G10K1-D-74
90
BXRC-56G10K0-B-74
80
BXRC-56G10K0-C-74
80
BXRC-56G10K0-D-74
80
BXRC-56H10K1-D-74
97
BXRC-57C10K1-B-74
70
BXRC-57C10K1-C-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7057
9292
13594
19595
25079
9791
12444
17235
24450
30646
6308
8118
11467
16326
20576
7407
9753
14268
20568
26324
10277
13062
18091
25664
32167
6621
8521
12037
17136
21597
5726
7369
10410
14820
18679
8558
11269
16486
23764
30415
11874
15092
20902
29652
37166
6442
8446
12234
17475
22097
9317
11479
15512
21029
25751
6146
7555
10321
13756
16802
6761
8866
12842
18343
23194
9779
12049
16282
22073
27029
6451
7930
10833
14439
17636
5579
6858
9369
12487
15253
7812
10243
14837
21193
26798
11299
13921
18812
25503
31230
158
153
145
134
125
173
162
145
132
120
170
160
145
131
119
166
161
152
141
131
182
170
152
139
126
178
168
152
138
125
154
146
132
119
108
192
186
176
163
151
210
197
176
160
146
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57C10K1-D-74
70
BXRC-57E10K1-B-74
80
BXRC-57E10K1-C-74
80
BXRC-57E10K1-D-74
80
BXRC-65C10K1-B-74
70
BXRC-65C10K1-C-74
70
BXRC-65C10K1-D-74
70
BXRC-65E10K1-B-74
80
BXRC-65E10K1-C-74
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7650
9845
13907
19799
24954
8212
10812
15818
22802
29184
11393
14481
20056
28452
35662
7340
9446
13344
18998
23944
8708
11466
16775
24181
30949
12082
15356
21269
30172
37818
7784
10018
14151
20146
25392
8357
11004
16099
23207
29702
11595
14738
20412
28957
36295
7454
9162
12517
16682
20377
7496
9829
14237
20335
25713
10842
13357
18050
24471
29966
7152
8791
12010
16007
19552
7949
10423
15097
21565
27268
11497
14165
19142
25951
31778
7584
9323
12736
16975
20734
7629
10003
14489
20696
26170
11034
13595
18371
24905
30498
206
194
176
159
144
184
179
169
156
145
201
189
169
154
140
197
187
169
153
138
195
189
179
166
154
214
200
179
163
149
209
198
179
162
147
187
182
172
159
148
205
192
172
157
143
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
BXRC-65E10K1-D-74
CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
80
1050
1400
2100
3150
4200
35.4
36.2
37.6
39.5
41.2
37.2
50.6
79.0
124.4
172.9
7470
9614
13581
19335
24369
7279
8947
12223
16291
19899
201
190
172
155
141
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
19
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.06
46.1
57.5
-24.9
0.07
49.7
61.6
74.6
-33.2
0.04
61.5
76.8
74.4
80.0
-33.2
0.05
66.2
82.2
34.8
37.6
40.4
-17.4
0.06
33.4
41.6
38.1
41.2
44.3
-17.4
0.07
36.7
45.4
Minimum
Typical
Maximum
1800
48.1
52.0
55.9
-24.9
3600
51.7
55.8
60.0
1710
64.2
69.4
3420
68.8
2100
4200
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
20
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1800
RG1
RG1
RG1
RG1
2700
RG1
RG1
RG2
RG2
3600
RG1
RG1
RG2
RG2
1710
RG1
RG1
RG1
RG2
2565
RG1
RG1
RG2
RG2
3420
RG1
RG2
RG2
RG2
2100
RG1
RG1
RG1
RG1
3150
RG1
RG1
RG1
RG2
4200
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed
.
21
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
125°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
Maximum Drive Current3
3600mA
3420mA
4200mA
Maximum Peak Pulsed Drive Current4,5
5140mA
4890mA
6000mA
Maximum Reverse Voltage6
-90V
-120V
-65V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector
is 3150mA.
5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
22
Performance Curves
Figure 2: Vero 29C Drive Current vs. Voltage
4000
4000
3500
3500
3000
3000
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero 29B Drive Current vs. Voltage
2500
2000
1500
1000
2500
2000
1500
1000
500
0
500
47
48
49
50
51
52
53
54
55
56
57
0
58
63
64
65
66
67
68
Forward Voltage (V)
Figure 3: Vero 29D Drive Current vs. Voltage
71
72
73
74
75
76
200%
180%
4000
160%
Relative Luminous Flux
3500
Forward Current (mA)
70
Figure 4: Vero 29B Typical Relative Flux vs. Current
4500
3000
2500
2000
1500
1000
140%
120%
100%
80%
60%
40%
500
0
69
Forward Voltage (V)
20%
33
34
35
36
37
38
39
40
41
42
0%
0
Forward Voltage (V)
500
1000
1500
2000
2500
3000
3500
4000
Forward Current (mA)
Figure 6: Vero 29D Typical Relative Flux vs. Current
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
Figure 5: Vero 29C Typical Relative Flux vs. Current
120%
100%
80%
60%
120%
100%
80%
60%
40%
40%
20%
20%
0%
0
400
800
1200
1600
2000
2400
Forward Current (mA)
2800
3200
3600
4000
0%
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
23
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
Figure 7: Typical DC Flux vs. Case Temperature
0
103%
Neutral White
50
75
100
125
0.000
Cool White
25°C Pulsed
97%
-0.003
ccy Shift
Relative Luminous Flux
100%
25
0.003
Warm White
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
-0.015
82%
0
25
50
75
100
Neutral White
Cool White
25°C Pulsed
125
Case Temperature (°C)
Case Temperature (°C)
Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 9: Typical DC ccx Shift vs. Case Temperature
0 .410 1
0
25
50
75
100
0 .41
125
0 .4099
0.000
0 .4098
-0.002
Pulsed C enter
Point T c =25°C
15°C
25°C
0 .4097
ccy
ccx Shift
-0.004
-0.006
65°C
0 .4093
Warm White
-0.012
0 .4095
0 .4094
-0.008
-0.010
45°C
0 .4096
Neutral White
85°C
0 .4092
Cool White
25°C Pulsed
10 5°C
0 .4091
Case Temperature (°C)
0 .409
0 .525
0 .526
0 .527
0 .528
0 .529
0 .53
0 .531
0 .532
ccx
Notes for Figures 7 - 9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
24
Performance Curves
Figure 12: 2500K Color Shift vs. Case Temperature1
Figure 11: 1750K Color Shift vs. Case Temperature1
0 .370 5
0 .4145
Pulsed C enter Point
T c = 25°C
15°C
0 .37
15°C
0 .414
25°C
0 .4135
25°C
0 .413
0 .3695
0 .369
ccy
ccy
45°C
85°C
0 .411
10 5°C
0 .5198
0 .52
70 °C
85°C
0 .4115
0 .3685
0 .368
0 .5196
45°C
0 .4125
0 .412
70 °C
0 .5202
0 .5204
10 5°C
0 .410 5
0 .468
0 .5206
0 .47
0 .472
0 .474
0 .344
0 .369
15°C
0 .342
25°C
0 .338
0 .367
ccy
ccy
25°C
0 .332
70 °C
0 .33
0 .365
0 .364
70 °C
0 .363
85°C
0 .328
Pulsed
C enter Point
T c =25°C
45°C
45°C
0 .334
0 .326
0 .368
Pulsed C enter
Point
T c = 25°C
0 .366
0 .336
0 .478
Figure 14: 3000K, Class A Color Shift vs. Case Temperature1
Figure 13: 5600K Color Shift vs. Case Temperature1,3
0 .34
0 .476
ccx
ccx
15°C
Pulsed
C enter Point
T c = 25°C
85°C
0 .362
10 5°C
0 .361
0 .324
0 .322
0 .32
0 .322
0 .324
0 .326
0 .328
10 5°C
0 .36
0 .416
0 .33
0 .4165
0 .417
ccx
Figure 15: 3500K, Class A Color Shift vs. Case Temperature1
ccx
0 .4175
0 .418
0 .4185
Figure 16: 4000K, Class A Color Shift vs. Case Temperature1
0 .37
0 .3760
15°C
0 .368
25°C
0 .366
Pulsed
C enter Point
T c =25°C
15°C
0 .3740
25°C
0 .3720
45°C
45°C
ccy
0 .370 0
ccy
Pulsed
C enter Point
T c =25°C
0 .364
0 .3680
70 °C
0 .362
85°C
0 .36
85°C
0 .3640
10 5°C
0 .358
0 .392
70 °C
0 .3660
10 5°C
0 .393
0 .394
0 .395
0 .396
0 .397
ccx
0 .3620
0 .373
0 .374
0 .375
0 .376
ccx
0 .377
0 .378
0 .379
Note for Figures 10-16:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
25
Performance Curves
Figure 17: Vero 29D Drive Current Derating Curve
440 0
Drive Curre nt (mA)
420 0
40 0 0
3960
380 0
360 0
340 0
Max Drive C urrent
L M- 80 Max Drive C urrent
320 0
0
10
20
30
40
50
60
70
80
90
10 0
110
Cas e T e mpe rature (⁰ C)
Notes for Figure 17:
1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product
Feature Map (page 2) for the location of the Tc Point
2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections.
3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included
in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report.
26
Typical Radiation Pattern
Figure 18: Typical Spatial Radiation Pattern
Note for Figure 18:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 19: Typical Polar Radiation Pattern
27
Typical Color Spectrum
Figure 20: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 20:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 21: Typical Color Spectrum for Vero 29 with Décor Series
1
17E
20 B
0 .9
25E
27H
R e lative S pe c tral Pow e r Dis tribution
0 .8
30 H
56G
0 .7
56H
0 .6
0 .5
0 .4
0 .3
0 .2
0 .1
0
40 0
450
50 0
550
600
W ave le ngth (nm)
6 50
70 0
750
80 0
Note for Figure 21:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
28
Mechanical Dimensions
Figure 22: Drawing for Vero 29 LED Array
Notes for Figure 22:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ± 0.10mm.
4. Mounting holes (4X) are for M3 screws.
5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
29
Color Binning Information
Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space
0 .44
250 0 K
4S DCM
3 S DCM
4 S DCM
0 .42
20 0 0 K
3S DCM
270 0 K
30 0 0 K
350 0 K
0 .4
Y
40 0 0 K
1750 K
4S DCM
0 .38
0 .36
0 .34
0 .36
0 .39
0 .42
0 .45
X
0 .48
0 .51
0 .54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2000K
2500K
2700K
3000K1
3500K1
4000K1
(for reference only)
ANSI Bin
-
-
-
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
-
-
-
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
-
-
-
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.5167, 0.336)
(0.5280, 0.4100)
(0.4765, 0.4137)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
Figure 24: Graph of Cool White Test Bins in xy Color Space
0 .39
4 S DC M
3 S DC M
0 .38
0 .37
5000K
0 .36
5700K
Y
0 .35
0 .34
6500K
0 .33
0 .32
0 .31
0 .3
0 .3
0 .31
0 .32
0 .33
0 .34
0 .35
0 .36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K1
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
30
Packaging and Labeling
Figure 25: Drawing for Vero 29 Packaging Tray
Notes for Figure 25:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
31
Packaging and Labeling
Figure 26: Vero Series Packaging and Labeling
Notes for Figure 26:
1. Each tray holds 50 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 27: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E10K0C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
32
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
33
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 Vero 29 Array Series Product Data Sheet DS93 Rev. N (09/2018)