Bridgelux Gen 7 Vero 10 Array
®
®
Product Data Sheet DS90
1
Vero® Series
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing
unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color
points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher efficacy.
Features
• Efficacy of 167 lm/W typical
• Lumen output performance ranges from 520 to
4,100 lumens
• Broad range of CCT options from 2700K to 6500K
• CRI options include minimum 65, 70, 80, and 90
• 2 and 3 SDCM color control for 2700K-4000K CCT
• Reliable operation at up to 2X nominal drive current
• Radial die pattern and improved lumen density
Benefits
• Broad application coverage for interior and exterior
lighting
• Flexibility for application driven lighting design
requirements
• High quality true color reproduction
• Uniform consistent white light
• Flexibility in design optimization
• Enhanced ease of use and assembly
• Thermally isolated solder pads
• Solderless connectivity enables plug & play
installation and field upgradability
• On-board connector port
• Improved inventory management and quality control
• Top side part number markings
• Vf bin code backside marking
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
19
Eye Safety
20
Absolute Maximum Ratings
21
Performance Curves
22
Typical Radiation Pattern
25
Typical Color Spectrum
26
Mechanical Dimensions
27
Color Binning Information
28
Packaging and Labeling
29
Design Resources
31
Precautions
31
Disclaimers
31
About Bridgelux
32
1
Product Feature Map
Vero 10 is the smallest form factor in the Vero family of
next generation solid state light sources. In addition to
delivering the performance and light quality required
for many lighting applications, Vero incorporates several
features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
2D Bar code provides full
manufacturing traceability
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
Mounting holes
Top side part number marking improves
inventory management and outgoing
quality control
Radial die configuration improves lumen
density and beam control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6 7 8 9 10 11
– 12
– 13 14
BXRC – 30 E 100 0 – C – 7 3
CCT Bin Options
Product Family
Nominal CCT
20 = 2,000K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen. 7
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
100x = 1000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
152
BXRC-20B1000-B-73
2000
65
270
1431
1259
34.8
9.4
BXRC-20B1000-D-73
2000
65
350
1386
1220
26.0
9.1
152
BXRC-27E1000-B-7x
2700
80
270
1458
1283
34.8
9.4
155
BXRC-27E1000-C-7x
2700
80
360
1944
1711
34.8
12.5
155
BXRC-27E1000-D-7x
2700
80
350
1412
1243
26.0
9.1
155
BXRC-27G10H0-B-7x
2700
90
270
1249
1099
34.8
9.4
133
BXRC-27G10H0-C-7x
2700
90
360
1665
1465
34.8
12.5
133
BXRC-27G10H0-D-7x
2700
90
350
1209
1064
26.0
9.1
133
BXRC-27G1000-B-7x
2700
90
270
1203
1059
34.8
9.4
128
BXRC-27G1000-C-7x
2700
90
360
1604
1412
34.8
12.5
128
BXRC-27G1000-D-7x
2700
90
350
1165
1025
26.0
9.1
128
BXRC-27H1000-B-7x
2700
97
270
1066
938
34.8
9.4
113
BXRC-27H1000-C-7x
2700
97
360
1422
1251
34.8
12.5
113
BXRC-27H1000-D-7x
2700
97
350
1033
909
26.0
9.1
113
BXRC-30C1001-B-74
3000
70
270
1622
1428
34.8
9.4
173
BXRC-30C1001-C-74
3000
70
360
2163
1904
34.8
12.5
173
BXRC-30C1001-D-74
3000
70
350
1571
1383
26.0
9.1
173
BXRC-30E1000-B-7x
3000
80
270
1549
1363
34.8
9.4
165
BXRC-30E1000-C-7x
3000
80
360
2066
1818
34.8
12.5
165
BXRC-30E1000-D-7x
3000
80
350
1501
1321
26.0
9.1
165
BXRC-30G10H0-B-7x
3000
90
270
1312
1155
34.8
9.4
140
BXRC-30G10H0-C-7x
3000
90
360
1750
1540
34.8
12.5
140
BXRC-30G10H0-D-7x
3000
90
350
1271
1119
26.0
9.1
140
BXRC-30G1000-B-7x
3000
90
270
1258
1107
34.8
9.4
134
134
BXRC-30G1000-C-7x
3000
90
360
1677
1476
34.8
12.5
BXRC-30G1000-D-7x
3000
90
350
1218
1072
26.0
9.1
134
BXRC-30G100C-B-73
3000
90
270
1212
1067
34.8
9.4
129
BXRC-30G100C-D-73
3000
90
350
1174
1033
26.0
9.1
129
BXRC-30H1000-B-7x
3000
97
270
1139
1003
34.8
9.4
121
BXRC-30H1000-C-7x
3000
97
360
1519
1337
34.8
12.5
121
BXRC-30H1000-D-7x
3000
97
350
1103
971
26.0
9.1
121
BXRC-30A1001-B-73
3000
93
270
1130
995
34.8
9.4
120
8,9
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI
Nominal Drive
Current3
(mA)
2
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A1001-C-738,9
3000
93
360
1507
1326
34.8
12.5
120
BXRC-30A1001-D-738,9
3000
93
350
1095
963
26.0
9.1
120
BXRC-35E1000-B-7x
3500
80
270
1586
1396
34.8
9.4
169
BXRC-35E1000-C-7x
3500
80
360
2114
1861
34.8
12.5
169
BXRC-35E1000-D-7x
3500
80
350
1536
1352
26.0
9.1
169
BXRC-35G1000-B-7x
3500
90
270
1303
1147
34.8
9.4
139
BXRC-35G1000-C-7x
3500
90
360
1738
1529
34.8
12.5
139
BXRC-35G1000-D-7x
3500
90
350
1262
1111
26.0
9.1
139
BXRC-35A1001-B-738,9
3500
93
270
1203
1059
34.8
9.4
128
BXRC-35A1001-C-73
8,9
3500
93
360
1604
1412
34.8
12.5
128
BXRC-35A1001-D-738,9
3500
93
350
1165
1025
26.0
9.1
128
BXRC-40C1001-B-74
4000
70
270
1668
1468
34.8
9.4
178
178
BXRC-40C1001-C-74
4000
70
360
2224
1957
34.8
12.5
BXRC-40C1001-D-74
4000
70
350
1615
1422
26.0
9.1
178
BXRC-40E1000-B-7x
4000
80
270
1595
1404
34.8
9.4
170
BXRC-40E1000-C-7x
4000
80
360
2127
1871
34.8
12.5
170
BXRC-40E1000-D-7x
4000
80
350
1545
1359
26.0
9.1
170
BXRC-40G1000-B-7x
4000
90
270
1331
1171
34.8
9.4
142
BXRC-40G1000-C-7x
4000
90
360
1774
1561
34.8
12.5
142
BXRC-40G1000-D-7x
4000
90
350
1289
1134
26.0
9.1
142
BXRC-40H1000-B-7x
4000
97
270
1203
1059
34.8
9.4
128
128
BXRC-40H1000-C-7x
4000
97
360
1604
1412
34.8
12.5
BXRC-40H1000-D-7x
4000
97
350
1165
1025
26.0
9.1
128
BXRC-40A1001-B-738,9
4000
93
270
1303
1147
34.8
9.4
139
BXRC-40A1001-C-738,9
4000
93
360
1738
1529
34.8
12.5
139
BXRC-40A1001-D-738,9
4000
93
350
1262
1111
26.0
9.1
139
BXRC-50C1001-B-7x
5000
70
270
1677
1476
34.8
9.4
178
BXRC-50C1001-C-7x
5000
70
360
2236
1968
34.8
12.5
178
BXRC-50C1001-D-7x
5000
70
350
1624
1429
26.0
9.1
178
BXRC-50E1001-B-7x
5000
80
270
1613
1420
34.8
9.4
172
BXRC-50E1001-C-7x
5000
80
360
2151
1893
34.8
12.5
172
BXRC-50E1001-D-7x
5000
80
350
1562
1375
26.0
9.1
172
BXRC-50G1001-B-7x
5000
90
270
1394
1227
34.8
9.4
148
BXRC-50G1001-C-7x
5000
90
360
1859
1636
34.8
12.5
148
BXRC-50G1001-D-7x
5000
90
350
1351
1188
26.0
9.1
148
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI
2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C1001-B-7x
5700
70
270
1631
1436
34.8
9.4
174
BXRC-57C1001-C-7x
5700
70
360
2175
1914
34.8
12.5
174
BXRC-57C1001-D-7x
5700
70
350
1580
1390
26.0
9.1
174
BXRC-57E1001-B-7x
5700
80
270
1549
1363
34.8
9.4
165
BXRC-57E1001-C-7x
5700
80
360
2066
1818
34.8
12.5
165
BXRC-57E1001-D-7x
5700
80
350
1501
1321
26.0
9.1
165
BXRC-65C1001-B-7x
6500
70
270
1631
1436
34.8
9.4
174
BXRC-65C1001-C-7x
6500
70
360
2175
1914
34.8
12.5
174
BXRC-65C1001-D-7x
6500
70
350
1580
1390
26.0
9.1
174
BXRC-65E1001-B-7x
6500
80
270
1568
1380
34.8
9.4
167
BXRC-65E1001-C-7x
6500
80
360
2090
1839
34.8
12.5
167
BXRC-65E1001-D-7x
6500
80
350
1518
1336
26.0
9.1
167
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A1001-B-73
3000
80
93
270
1051
875
34.3
9.3
114
BXRC-30A1001-C-73
3000
80
93
360
1401
1167
34.3
12.3
114
BXRC-30A1001-D-73
3000
80
93
350
1018
848
25.5
8.9
114
BXRC-35A1001-B-73
3500
80
93
270
1119
1228
34.3
9.3
121
BXRC-35A1001-C-73
3500
80
93
360
1492
1637
34.3
12.3
121
BXRC-35A1001-D-73
3500
80
93
350
1084
1189
25.5
8.9
122
BXRC-40A1001-B-73
4000
80
93
270
1212
1009
34.3
9.3
131
BXRC-40A1001-C-73
4000
80
93
360
1616
1346
34.3
12.3
131
BXRC-40A1001-D-73
4000
80
93
350
1174
977
25.5
8.9
132
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-20B1000-B-73
2000
65
270
1288
1133
33.8
9.1
141
BXRC-20B1000-D-73
2000
65
350
1247
1098
25.3
8.9
141
BXRC-27E1000-B-7x
2700
80
270
1312
1155
33.8
9.1
144
BXRC-27E1000-C-7x
2700
80
360
1750
1540
33.8
12.2
144
BXRC-27E1000-D-7x
2700
80
350
1271
1119
25.3
8.9
144
BXRC-27G10H0-B-7x
2700
90
270
1124
989
33.8
9.1
123
BXRC-27G10H0-C-7x
2700
90
360
1498
1319
33.8
12.2
123
BXRC-27G10H0-D-7x
2700
90
350
1088
958
25.3
8.9
123
BXRC-27G1000-B-7x
2700
90
270
1083
953
33.8
9.1
119
BXRC-27G1000-C-7x
2700
90
360
1444
1270
33.8
12.2
119
BXRC-27G1000-D-7x
2700
90
350
1049
923
25.3
8.9
118
BXRC-27H1000-B-7x
2700
97
270
960
845
33.8
9.1
105
BXRC-27H1000-C-7x
2700
97
360
1280
1126
33.8
12.2
105
BXRC-27H1000-D-7x
2700
97
350
929
818
25.3
8.9
105
BXRC-30C1001-B-74
3000
70
270
1460
1285
33.8
9.1
160
BXRC-30C1001-C-74
3000
70
360
1947
1713
33.8
12.2
160
BXRC-30C1001-D-74
3000
70
350
1414
1244
25.3
8.9
160
BXRC-30E1000-B-7x
3000
80
270
1394
1227
33.8
9.1
153
BXRC-30E1000-C-7x
3000
80
360
1859
1636
33.8
12.2
153
BXRC-30E1000-D-7x
3000
80
350
1351
1188
25.3
8.9
153
BXRC-30G10H0-B-7x
3000
90
270
1181
1039
33.8
9.1
129
BXRC-30G10H0-C-7x
3000
90
360
1575
1386
33.8
12.2
129
BXRC-30G10H0-D-7x
3000
90
350
1144
1007
25.3
8.9
129
BXRC-30G1000-B-7x
3000
90
270
1132
996
33.8
9.1
124
BXRC-30G1000-C-7x
3000
90
360
1509
1328
33.8
12.2
124
BXRC-30G1000-D-7x
3000
90
350
1096
965
25.3
8.9
124
BXRC-30G100C-B-73
3000
90
270
1091
960
33.8
9.1
120
BXRC-30G100C-D-73
3000
90
350
1057
930
25.3
8.9
119
BXRC-30H1000-B-7x
3000
97
270
1025
902
33.8
9.1
112
BXRC-30H1000-C-7x
3000
97
360
1367
1203
33.8
12.2
112
BXRC-30H1000-D-7x
3000
97
350
993
874
25.3
8.9
112
BXRC-30A1001-B-737,8
3000
93
270
1017
895
33.8
9.1
111
BXRC-30A1001-C-737,8
3000
93
360
1356
1193
33.8
12.2
111
BXRC-30A1001-D-73
3000
93
350
985
867
25.3
8.9
111
3500
80
270
1427
1256
33.8
9.1
156
7,8
BXRC-35E1000-B-7x
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the
minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E1000-C-7x
3500
80
360
1903
1675
33.8
12.2
156
BXRC-35E1000-D-7x
3500
80
350
1382
1216
25.3
8.9
156
BXRC-35G1000-B-7x
3500
90
270
1173
1032
33.8
9.1
128
BXRC-35G1000-C-7x
3500
90
360
1564
1376
33.8
12.2
128
BXRC-35G1000-D-7x
3500
90
350
1136
1000
25.3
8.9
128
BXRC-35A1001-B-73
7,8
3500
93
270
1083
953
33.8
9.1
119
BXRC-35A1001-C-737,8
3500
93
360
1444
1270
33.8
12.2
119
BXRC-35A1001-D-737,8
3500
93
350
1049
923
25.3
8.9
118
BXRC-40C1001-B-74
4000
70
270
1501
1321
33.8
9.1
164
BXRC-40C1001-C-74
4000
70
360
2001
1761
33.8
12.2
164
BXRC-40C1001-D-74
4000
70
350
1454
1279
25.3
8.9
164
BXRC-40E1000-B-7x
4000
80
270
1435
1263
33.8
9.1
157
BXRC-40E1000-C-7x
4000
80
360
1914
1684
33.8
12.2
157
BXRC-40E1000-D-7x
4000
80
350
1390
1223
25.3
8.9
157
BXRC-40G1000-B-7x
4000
90
270
1198
1054
33.8
9.1
131
BXRC-40G1000-C-7x
4000
90
360
1597
1405
33.8
12.2
131
BXRC-40G1000-D-7x
4000
90
350
1160
1021
25.3
8.9
131
BXRC-40H1000-B-7x
4000
97
270
1083
953
33.8
9.1
119
BXRC-40H1000-C-7x
4000
97
360
1444
1270
33.8
12.2
119
BXRC-40H1000-D-7x
4000
97
350
1049
923
25.3
8.9
118
BXRC-40A1001-B-737,8
4000
93
270
1173
1032
33.8
9.1
128
128
BXRC-40A1001-C-737,8
4000
93
360
1564
1376
33.8
12.2
BXRC-40A1001-D-737,8
4000
93
350
1136
1000
25.3
8.9
128
BXRC-50C1001-B-7x
5000
70
270
1509
1328
33.8
9.1
165
BXRC-50C1001-C-7x
5000
70
360
2012
1771
33.8
12.2
165
BXRC-50C1001-D-7x
5000
70
350
1462
1286
25.3
8.9
165
BXRC-50E1001-B-7x
5000
80
270
1452
1278
33.8
9.1
159
BXRC-50E1001-C-7x
5000
80
360
1936
1704
33.8
12.2
159
BXRC-50E1001-D-7x
5000
80
350
1406
1237
25.3
8.9
159
BXRC-50G1001-B-7x
5000
90
270
1255
1104
33.8
9.1
137
BXRC-50G1001-C-7x
5000
90
360
1673
1473
33.8
12.2
137
BXRC-50G1001-D-7x
5000
90
350
1215
1070
25.3
8.9
137
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the
minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C1001-B-7x
5700
70
270
1468
1292
33.8
9.1
161
BXRC-57C1001-C-7x
5700
70
360
1958
1723
33.8
12.2
161
BXRC-57C1001-D-7x
5700
70
350
1422
1251
25.3
8.9
161
BXRC-57E1001-B-7x
5700
80
270
1394
1227
33.8
9.1
153
BXRC-57E1001-C-7x
5700
80
360
1859
1636
33.8
12.2
153
BXRC-57E1001-D-7x
5700
80
350
1351
1188
25.3
8.9
153
BXRC-65C1001-B-7x
6500
70
270
1468
1292
33.8
9.1
161
BXRC-65C1001-C-7x
6500
70
360
1958
1723
33.8
12.2
161
BXRC-65C1001-D-7x
6500
70
350
1422
1251
25.3
8.9
161
BXRC-65E1001-B-7x
6500
80
270
1411
1242
33.8
9.1
154
BXRC-65E1001-C-7x
6500
80
360
1881
1655
33.8
12.2
154
BXRC-65E1001-D-7x
6500
80
350
1366
1202
25.3
8.9
154
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the
minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-20B1001-B-73
65
BXRC-20B1001-D-73
65
BXRC-27E1000-B-7x
80
BXRC-27E1000-C-7x
80
BXRC-27E1000-D-7x
80
BXRC-27G10H0-B-7x
90
BXRC-27G10H0-C-7x
90
BXRC-27G10H0-D-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
180
270
405
540
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
4.5
6.1
9.4
14.4
19.5
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
762
1000
1431
2099
2689
740
971
1386
2040
2613
777
1019
1458
2139
2741
1034
1354
1944
2831
3617
754
989
1412
2079
2663
665
872
1249
1832
2347
885
1160
1665
2424
3097
646
847
1209
1780
2280
685
897
1288
1867
2380
673
873
1247
1759
2201
698
914
1312
1903
2426
922
1203
1750
2460
3096
686
889
1271
1793
2243
598
783
1124
1630
2077
790
1030
1498
2106
2651
587
762
1088
1535
1920
170
163
152
145
138
170
164
152
142
131
173
166
155
148
140
173
166
155
147
139
173
167
155
145
134
148
143
133
127
120
148
142
133
126
119
148
143
133
124
115
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27G1000-B-7x
90
BXRC-27G1000-C-7x
90
BXRC-27G1000-D-7x
90
BXRC-27H1000-B-7x
97
BXRC-27H1000-C-7x
97
BXRC-27H1000-D-7x
97
BXRC-30C1001-B-74
70
BXRC-30C1001-C-74
70
BXRC-30C1001-D-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
641
841
1203
1765
2261
853
1117
1604
2336
2984
622
816
1165
1715
2197
568
745
1066
1564
2004
756
990
1422
2070
2645
551
723
1033
1520
1948
864
1134
1622
2380
3049
1150
1507
2163
3150
4023
839
1101
1571
2313
2963
576
754
1083
1570
2001
761
993
1444
2029
2554
566
734
1049
1479
1850
511
668
960
1392
1774
675
880
1280
1799
2264
501
650
929
1311
1640
777
1017
1460
2117
2699
1026
1338
1947
2736
3444
763
990
1414
1995
2495
143
137
128
122
116
143
137
128
121
115
143
138
128
119
110
127
122
113
108
103
126
121
113
108
102
126
122
113
106
98
193
185
173
165
156
192
185
173
164
155
192
186
173
161
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30E1000-B-7x
80
BXRC-30E1000-C-7x
80
BXRC-30E1000-D-7x
80
BXRC-30G10H0-B-7x
90
BXRC-30G10H0-C-7x
90
BXRC-30G10H0-D-7x
90
BXRC-30G1000-B-7x
90
BXRC-30G1000-C-7x
90
BXRC-30G1000-D-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
826
1083
1549
2273
2912
1098
1439
2066
3008
3843
801
1051
1501
2209
2830
699
917
1312
1925
2467
930
1219
1750
2548
3255
679
890
1271
1871
2397
670
879
1258
1845
2364
892
1168
1677
2442
3119
650
853
1218
1793
2297
742
971
1394
2022
2577
980
1278
1859
2613
3289
729
945
1351
1905
2383
628
823
1181
1713
2183
830
1083
1575
2214
2786
617
801
1144
1614
2018
602
788
1132
1641
2092
796
1038
1509
2121
2670
591
767
1096
1546
1934
184
177
165
157
149
184
176
165
156
148
184
178
165
154
142
156
150
140
133
126
156
149
140
132
125
156
150
140
130
121
149
144
134
128
121
149
143
134
127
120
149
144
134
125
115
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G100C-B-73
90
BXRC-30G100C-D-73
90
BXRC-30H1000-B-7x
97
BXRC-30H1000-C-7x
97
BXRC-30H1000-D-7x
97
BXRC-30A1001-B-73
93
BXRC-30A1001-C-73
93
BXRC-30A1001-D-73
93
BXRC-35E1000-B-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
135
180
270
405
540
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
4.5
6.1
9.4
14.4
19.5
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
646
847
1212
1778
2278
627
822
1174
1728
2214
607
796
1139
1671
2141
808
1058
1519
2212
2825
589
773
1103
1624
2081
602
790
1130
1658
2124
801
1050
1507
2194
2803
584
767
1095
1611
2064
845
1108
1586
2327
2981
580
760
1091
1582
2016
570
739
1057
1490
1864
546
714
1025
1487
1895
721
940
1367
1922
2419
536
695
993
1401
1752
541
708
1017
1475
1880
715
932
1356
1906
2399
531
689
985
1390
1738
759
994
1427
2070
2638
144
138
129
123
117
144
139
129
120
111
135
130
121
116
110
135
130
121
115
109
135
131
121
113
105
134
129
120
115
109
134
129
120
114
108
134
130
120
112
104
188
181
169
161
153
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35E1000-C-7x
80
BXRC-35E1000-D-7x
80
BXRC-35G1000-B-7x
90
BXRC-35G1000-C-7x
90
BXRC-35G1000-D-7x
90
BXRC-35A1001-B-73
93
BXRC-35A1001-C-73
93
BXRC-35A1001-D-73
93
BXRC-40C1001-B-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
1124
1473
2114
3079
3933
820
1076
1536
2261
2896
695
911
1303
1912
2450
924
1210
1738
2530
3232
674
884
1262
1858
2380
641
841
1203
1765
2261
853
1117
1604
2336
2984
622
816
1165
1715
2197
889
1165
1668
2447
3135
1003
1308
1903
2675
3367
746
967
1382
1950
2439
624
817
1173
1701
2168
824
1075
1564
2198
2767
613
795
1136
1602
2004
576
754
1083
1570
2001
761
993
1444
2029
2554
566
734
1049
1479
1850
799
1045
1501
2177
2775
188
180
169
160
151
188
182
169
157
146
155
149
139
132
126
155
148
139
131
124
155
149
139
129
120
143
137
128
122
116
143
137
128
121
115
143
138
128
119
110
198
190
178
170
161
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C1001-C-74
70
BXRC-40C1001-D-74
70
BXRC-40E1000-B-7x
80
BXRC-40E1000-C-7x
80
BXRC-40E1000-D-7x
80
BXRC-40G1000-B-7x
90
BXRC-40G1000-C-7x
90
BXRC-40G1000-D-7x
90
BXRC-40H1000-B-7x
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
1182
1549
2224
3238
4136
862
1131
1615
2378
3046
850
1114
1595
2340
2998
1131
1481
2127
3097
3956
825
1082
1545
2274
2913
709
930
1331
1952
2501
943
1236
1774
2584
3300
688
903
1289
1897
2430
641
841
1203
1765
2261
1055
1376
2001
2813
3541
784
1017
1454
2051
2565
764
1000
1435
2082
2653
1009
1316
1914
2690
3386
750
973
1390
1961
2453
637
834
1198
1737
2214
842
1098
1597
2244
2825
626
812
1160
1636
2047
576
754
1083
1570
2001
198
190
178
168
159
198
191
178
165
153
190
182
170
162
154
189
181
170
161
152
189
183
170
158
146
158
152
142
135
128
158
151
142
134
127
158
153
142
132
122
143
137
128
122
116
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40H1000-C-7x
97
BXRC-40H1000-D-7x
97
BXRC-40A1001-B-73
93
BXRC-40A1001-C-73
93
BXRC-40A1001-D-73
93
BXRC-50C1001-B-7x
70
BXRC-50C1001-C-7x
70
BXRC-50C1001-D-7x
70
BXRC-50E1001-B-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
853
1117
1604
2336
2984
622
816
1165
1715
2197
695
911
1303
1912
2450
924
1210
1738
2530
3232
674
884
1262
1858
2380
894
1172
1677
2460
3152
1189
1557
2236
3256
4159
867
1138
1624
2391
3063
860
1127
1613
2367
3032
761
993
1444
2029
2554
566
734
1049
1479
1850
624
817
1173
1701
2168
824
1075
1564
2198
2767
613
795
1136
1602
2004
803
1051
1509
2189
2790
1061
1384
2012
2828
3560
789
1023
1462
2062
2579
773
1011
1452
2105
2684
143
137
128
121
115
143
138
128
119
110
155
149
139
132
126
155
148
139
131
124
155
149
139
129
120
199
191
178
170
161
199
191
178
169
160
199
192
178
166
154
192
184
172
164
155
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50E1001-C-7x
80
BXRC-50E1001-D-7x
80
BXRC-50G1001-B-7x
90
BXRC-50G1001-C-7x
90
BXRC-50G1001-D-7x
90
BXRC-57C1001-B-7x
70
BXRC-57C1001-C-7x
70
BXRC-57C1001-D-7x
70
BXRC-57E1001-B-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
1144
1498
2151
3132
4001
834
1094
1562
2300
2946
743
974
1394
2046
2621
989
1295
1859
2707
3458
721
946
1351
1988
2547
869
1140
1631
2393
3066
1156
1515
2175
3167
4046
844
1107
1580
2326
2980
826
1083
1549
2273
2912
1020
1331
1936
2721
3425
759
984
1406
1983
2481
668
874
1255
1820
2320
882
1150
1673
2352
2960
656
851
1215
1714
2145
781
1022
1468
2129
2714
1032
1346
1958
2752
3463
767
995
1422
2006
2509
742
971
1394
2022
2577
191
184
172
163
154
191
185
172
160
148
166
159
148
142
134
165
159
148
141
133
165
160
148
138
128
194
186
174
166
157
193
186
174
165
155
193
187
174
162
150
184
177
165
157
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57E1001-C-7x
80
BXRC-57E1001-D-7x
80
BXRC-65C1001-B-7x
70
BXRC-65C1001-C-7x
70
BXRC-65C1001-D-7x
70
BXRC-65E1001-B-7x
80
BXRC-65E1001-C-7x
80
BXRC-65E1001-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
135
180
270
405
540
180
240
360
540
720
175
233
350
525
700
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
24.9
25.4
26.0
27.4
28.4
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
4.5
6.1
9.4
14.4
19.5
6.0
8.2
12.5
19.2
26.0
4.4
5.9
9.1
14.4
19.9
1098
1439
2066
3008
3843
801
1051
1501
2209
2830
869
1140
1631
2393
3066
1156
1515
2175
3167
4046
844
1107
1580
2326
2980
835
1095
1568
2300
2946
1111
1456
2090
3044
3888
811
1063
1518
2235
2863
980
1278
1859
2613
3289
729
945
1351
1905
2383
781
1022
1468
2129
2714
1032
1346
1958
2752
3463
767
995
1422
2006
2509
751
982
1411
2046
2608
992
1293
1881
2644
3328
737
956
1366
1927
2411
184
176
165
156
148
184
178
165
154
142
194
186
174
166
157
193
186
174
165
155
193
187
174
162
150
186
179
167
159
151
186
178
167
158
149
186
180
167
155
144
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx100x-B-7x
BXRC-xxx100x-C-7x
BXRC-xxx100x-D-7x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.49
30.9
38.5
-16.1
0.56
32.1
39.9
37.4
-16.1
0.37
30.9
38.5
36.1
38.8
-16.1
0.45
32.1
39.9
24.1
26.0
28.0
-11.8
0.49
23.1
28.7
26.3
28.4
30.5
-11.8
0.57
25.3
31.3
Minimum
Typical
Maximum
270
32.2
34.8
37.4
-16.1
540
33.4
36.1
38.8
360
32.2
34.8
720
33.4
350
700
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
19
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx100x-B-7x
BXRC-xxx100x-C-7x
BXRC-xxx100x-D-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
270
RG1
RG1
RG1
RG1
405
RG1
RG1
RG1
RG2
540
RG1
RG1
RG2
RG2
360
RG1
RG1
RG1
RG2
540
RG1
RG1
RG2
RG2
720
RG1
RG2
RG2
RG2
350
RG1
RG1
RG1
RG1
525
RG1
RG1
RG1
RG2
700
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
20
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx100x-B-7x
BXRC-xxx100x-C-7x
BXRC-xxx100x-D-7x
Maximum Drive Current3
540mA
720mA
700mA
Maximum Peak Pulsed Drive Current4
770mA
1030mA
1000mA
Maximum Reverse Voltage5
-60V
-60V
-45V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
21
Performance Curves
Figure 1: Vero 10B Drive Current vs. Voltage
Figure 2: Vero 10C Drive Current vs. Voltage
800
600
700
Forward Current (mA)
Forward Current (mA)
500
400
300
200
100
0
600
500
400
300
200
100
32
33
34
35
36
37
0
38
32
33
34
Forward Voltage (V)
Figure 3: Vero 10D Drive Current vs. Voltage
36
37
38
Figure 4: Vero 10B Typical Relative Flux vs. Current
200%
800
180%
700
160%
600
Relative Luminous Flux
Forward Current (mA)
35
Forward Voltage (V)
500
400
300
200
140%
120%
100%
80%
60%
40%
100
0
20%
24
25
26
27
28
0%
29
0
100
200
Forward Voltage (V)
Figure 5: Vero 10C Typical Relative Flux vs. Current
400
500
600
Figure 6 Vero 10D Typical Relative Flux vs. Current
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
300
Forward Current (mA)
120%
100%
80%
60%
120%
100%
80%
60%
40%
40%
20%
20%
0%
0%
0
100
200
300
400
500
Forward Current (mA)
600
700
800
0
100
200
300
400
500
600
700
800
Forward Current (mA)
Notes for Figure 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
22
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
Figure 7: Typical DC Flux vs. Case Temperature
0
103%
Neutral White
50
75
100
125
0.000
Cool White
25°C Pulsed
97%
-0.003
ccy Shift
Relative Luminous Flux
100%
25
0.003
Warm White
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
-0.015
82%
0
25
50
75
100
Neutral White
Cool White
25°C Pulsed
125
Case Temperature (°C)
Case Temperature (°C)
Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.4101
0
25
50
75
100
0.41
125
0.000
0.4099
0.4098
-0.002
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
ccy
ccx Shift
-0.004
-0.006
65°C
0.4093
Warm White
-0.012
0.4095
0.4094
-0.008
-0.010
45°C
0.4096
Neutral White
85°C
0.4092
Cool White
25°C Pulsed
105°C
0.4091
Case Temperature (°C)
0.409
0.525
0.526
0.527
0.528
0.529
0.53
0.531
0.532
ccx
Notes for Figures 7 - 9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
23
Performance Curves
Figure 11: 2700K, 97 CRI Color Shift vs. Case Temperature1
Figure 12: 3000K, 97 CRI Color Shift vs. Case Temperature1
0.4110
0.4050
15°C
Pulsed Center
Point
Tc = 25°C
0.4100
25°C
25°C
0.4090
45°C
0.4010
45°C
ccy
ccy
0.4080
Pulsed Center
Point
Tc = 25°C
15°C
0.4030
0.4070
65°C
70°C
0.3990
0.4060
85°C
85°C
0.4050
0.3970
105°C
0.4040
105°C
0.4030
0.457
0.3950
0.4323
0.4572
0.4574
0.4576
0.4578
0.4328
0.4333
0.458
Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature3
Pulsed Center
Point Tc=25°C
25°C
15°C
0.368
25°C
0.401
0.367
0.4
0.366
45°C
ccy
ccy
0.369
15°C
0.399
0.4343
65°C
0.398
0.397
0.4353
Pulsed
Center Point
Tc=25°C
45°C
0.365
0.364
70°C
0.363
85°C
0.4348
Figure 14: 3000K Class A Color Shift vs. Case Temperature1
0.403
0.402
0.4338
ccx
ccx
85°C
0.362
105°C
0.396
0.395
0.444
0.361
0.4445
0.445
0.4455
0.446
0.4465
0.447
105°C
0.36
0.416
0.4165
0.417
ccx
Figure 15: 3500K Class A Color Shift vs. Case Temperature1
ccx
0.4175
0.418
0.4185
Figure 16: 4000K Class A Color Shift vs. Case Temperature1
0.37
15°C
0.368
25°C
15°C
0.3740
25°C
0.3720
45°C
45°C
0.3700
0.364
70°C
0.362
0.3680
85°C
70°C
0.3660
0.36
85°C
0.3640
105°C
0.358
0.392
Pulsed
Center Point
Tc=25°C
ccy
ccy
0.366
0.3760
Pulsed
Center Point
Tc=25°C
105°C
0.393
0.394
0.395
0.396
0.397
ccx
Note for Figures 10-16:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRC-30G100C-x-73
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
24
Typical Radiation Pattern
Figure 17: Typical Spatial Radiation Pattern
Note for Figure 17:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 18: Typical Polar Radiation Pattern
25
Typical Color Spectrum
Figure 19: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 19:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 20: Typical Color Spectrum for Vero 10 with Décor Series
1
20B
27H
0.9
30G (Décor Series Showcase)
30H
Relative Spectral Power Distribution
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 20:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
26
Mechanical Dimensions
Figure 21: Drawing for Vero 10 LED Array
Notes for Figure 21:
1. Drawings are not to scale.
2. Dimensions are in mm.
3. Unless otherwise specified, tolerances are ± 0.10mm.
4. Mounting slots (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 19.0 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or
raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending
on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
27
Color Binning Information
Figure 22: Warm and Neutral White Test Bins in xy Color
Figure 23: Graph of Cool White Test Bins in xy Color Space
Space
0.44
0.39
4 SDCM
3 SDCM
2000K
3SDCM
2 SDCM
0.42
2700K
0.37
3000K
5000K
0.36
3500K
0.4
3 SDCM
0.38
5700K
0.35
Y
Y
4000K
0.34
0.38
6500K
0.33
0.36
0.32
0.31
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
2000K
2700K
3000K1
3500K1
4000K1
ANSI Bin
(for reference only)
-
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
-
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
-
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.5280, 0.4100)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4465, 0.4024)2
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5481K - 5829K)
(6270K - 6765K)
73 (3 SDCM)
(4835K-5215K)
(5490K-5820K)
(6250K-6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3287, 0.3417)
(0.3123, 0.3282)
28
Packaging and Labeling
Figure 24: Drawing for Vero 10 Packaging Tray
Notes for Figure 24:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
29
Packaging and Labeling
Figure 25: Vero Series Packaging and Labeling
Notes for Figure 25:
1. Each tray holds 200 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 26: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E1000C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
30
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
31
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 Vero 10 Array Series Product Data Sheet DS90 Rev. P (03/2019)
32