0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-40E2000-B-73

BXRC-40E2000-B-73

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO134000KROUND

  • 数据手册
  • 价格&库存
BXRC-40E2000-B-73 数据手册
Bridgelux Gen 7 Vero 13 Array ® ® Product Data Sheet DS91 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is also designed as a replacement for halogen lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features • Efficacy of 170 lm/W typical • Lumen output performance ranges from 460 to 7,300 lumens • Broad range of CCT options from 2700K to 6500K • CRI options include; minimum 70, 80, and 90 • 2 and 3 SDCM color control for 2700K-4000K CCT • Reliable operation at up to 2X nominal drive current • Radial die pattern and improved lumen density • Thermally isolated solder pads • Onboard connector port • Top side part number markings • Vf bin code backside marking Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Flexibility in design optimization • Enhanced ease of use and assembly • Solderless connectivity enables plug & play installation and field upgradability • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 19 Eye Safety 20 Absolute Maximum Ratings 21 Performance Curves 22 Typical Radiation Pattern 25 Typical Color Spectrum 26 Mechanical Dimensions 27 Color Binning Information 28 Packaging and Labeling 29 Design Resources 31 Precautions 31 Disclaimers 31 About Bridgelux 32 1 Product Feature Map Vero 13 is the second smallest form factor in the Vero family of the next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Optics location/mounting features Correlates to the true case temperature on the back surface of the LED array Mounting holes Radial die configuration improves lumen density and beam control Zhaga Book 3 compatible mounting locations Top side part number marking improves inventory management and outgoing quality control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 200 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 200x = 2000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x 2700 80 450 2506 2255 34.8 15.7 160 BXRC-27E2000-C-7x 2700 80 630 3508 3157 34.8 21.9 160 BXRC-27E2000-D-7x 2700 80 500 2544 2290 31.8 15.9 160 BXRC-27G20H0-B-7x 2700 90 450 2145 1931 34.8 15.7 137 BXRC-27G20H0-C-7x 2700 90 630 3004 2703 34.8 21.9 137 BXRC-27G20H0-D-7x 2700 90 500 2178 1960 31.8 15.9 137 BXRC-27G2000-B-7x 2700 90 450 2067 1860 34.8 15.7 132 BXRC-27G2000-C-7x 2700 90 630 2894 2605 34.8 21.9 132 BXRC-27G2000-D-7x 2700 90 500 2099 1889 31.8 15.9 132 BXRC-27H2000-B-7x 2700 97 450 1832 1649 34.8 15.7 117 BXRC-27H2000-C-7x 2700 97 630 2565 2309 34.8 21.9 117 BXRC-27H2000-D-7x 2700 97 500 1860 1674 31.8 15.9 117 BXRC-30C2001-B-74 3000 70 450 2787 2509 34.8 15.7 178 178 BXRC-30C2001-C-74 3000 70 630 3902 3512 34.8 21.9 BXRC-30C2001-D-74 3000 70 500 2830 2547 31.8 15.9 178 BXRC-30E2000-B-7x 3000 80 450 2662 2396 34.8 15.7 170 BXRC-30E2000-C-7x 3000 80 630 3727 3354 34.8 21.9 170 BXRC-30E2000-D-7x 3000 80 500 2703 2433 31.8 15.9 170 BXRC-30G20H0-B-7x 3000 90 450 2255 2030 34.8 15.7 144 BXRC-30G20H0-C-7x 3000 90 630 3157 2841 34.8 21.9 144 BXRC-30G20H0-D-7x 3000 90 500 2290 2061 31.8 15.9 144 BXRC-30G2000-B-7x 3000 90 450 2161 1945 34.8 15.7 138 BXRC-30G2000-C-7x 3000 90 630 3026 2723 34.8 21.9 138 BXRC-30G2000-D-7x 3000 90 500 2194 1975 31.8 15.9 138 BXRC-30G200C-B-73 3000 90 450 2095 1885 35.0 15.8 133 BXRC-30G200C-D-73 3000 90 500 2115 1903 31.8 15.9 133 BXRC-30H2000-B-7x 3000 97 450 1958 1762 34.8 15.7 125 BXRC-30H2000-C-7x 3000 97 630 2741 2466 34.8 21.9 125 BXRC-30H2000-D-7x 3000 97 500 1988 1789 31.8 15.9 125 BXRC-30A2001-B-738,9 3000 93 450 1942 1748 34.8 15.7 124 BXRC-30A2001-C-73 8,9 3000 93 630 2719 2447 34.8 21.9 124 BXRC-30A2001-D-738,9 3000 93 500 1972 1774 31.8 15.9 124 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x 3500 80 450 2725 2452 34.8 15.7 174 174 BXRC-35E2000-C-7x 3500 80 630 3815 3433 34.8 21.9 BXRC-35E2000-D-7x 3500 80 500 2767 2490 31.8 15.9 174 BXRC-35G2000-B-7x 3500 90 450 2239 2015 34.8 15.7 143 BXRC-35G2000-C-7x 3500 90 630 3135 2822 34.8 21.9 143 BXRC-35G2000-D-7x 3500 90 500 2274 2046 31.8 15.9 143 BXRC-35A2001-B-738,9 3500 93 450 2067 1860 34.8 15.7 132 BXRC-35A2001-C-738,9 3500 93 630 2894 2605 34.8 21.9 132 BXRC-35A2001-D-73 3500 93 500 2099 1889 31.8 15.9 132 BXRC-40C2001-B-74 4000 70 450 2866 2579 34.8 15.7 183 8,9 BXRC-40C2001-C-74 4000 70 630 4012 3611 34.8 21.9 183 BXRC-40C2001-D-74 4000 70 500 2910 2619 31.8 15.9 183 BXRC-40E2000-B-7x 4000 80 450 2741 2466 34.8 15.7 175 BXRC-40E2000-C-7x 4000 80 630 3837 3453 34.8 21.9 175 BXRC-40E2000-D-7x 4000 80 500 2783 2504 31.8 15.9 175 BXRC-40G2000-B-7x 4000 90 450 2286 2058 34.8 15.7 146 BXRC-40G2000-C-7x 4000 90 630 3201 2881 34.8 21.9 146 BXRC-40G2000-D-7x 4000 90 500 2321 2089 31.8 15.9 146 BXRC-40H2000-B-73 4000 97 450 2067 1860 34.8 15.7 132 BXRC-40H2000-C-73 4000 97 630 2894 2605 34.8 21.9 132 BXRC-40H2000-D-73 4000 97 500 2099 1889 31.8 15.9 132 BXRC-40A2001-B-738,9 4000 93 450 2239 2015 34.8 15.7 143 BXRC-40A2001-C-738,9 4000 93 630 3135 2822 34.8 21.9 143 BXRC-40A2001-D-738,9 4000 93 500 2274 2046 31.8 15.9 143 BXRC-50C2001-B-7x 5000 70 450 2881 2593 34.8 15.7 184 BXRC-50C2001-C-7x 5000 70 630 4034 3631 34.8 21.9 184 BXRC-50C2001-D-7x 5000 70 500 2926 2633 31.8 15.9 184 BXRC-50E2001-B-7x 5000 80 450 2772 2495 34.8 15.7 177 BXRC-50E2001-C-7x 5000 80 630 3881 3492 34.8 21.9 177 BXRC-50E2001-D-7x 5000 80 500 2814 2533 31.8 15.9 177 BXRC-50G2001-B-7x 5000 90 450 2396 2156 34.8 15.7 153 BXRC-50G2001-C-7x 5000 90 630 3354 3019 34.8 21.9 153 BXRC-50G2001-D-7x 5000 90 500 2433 2189 31.8 15.9 153 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C2001-B-7x 5700 70 450 2803 2523 34.8 15.7 179 179 BXRC-57C2001-C-7x 5700 70 630 3924 3532 34.8 21.9 BXRC-57C2001-D-7x 5700 70 500 2846 2561 31.8 15.9 179 BXRC-57E2001-B-7x 5700 80 450 2662 2396 34.8 15.7 170 BXRC-57E2001-C-7x 5700 80 630 3727 3354 34.8 21.9 170 BXRC-57E2001-D-7x 5700 80 500 2703 2433 31.8 15.9 170 BXRC-65C2001-B-7x 6500 70 450 2803 2523 34.8 15.7 179 BXRC-65C2001-C-7x 6500 70 630 3924 3532 34.8 21.9 179 BXRC-65C2001-D-7x 6500 70 500 2846 2561 31.8 15.9 179 BXRC-65E2001-B-7x 6500 80 450 2694 2424 34.8 15.7 172 BXRC-65E2001-C-7x 6500 80 630 3771 3394 34.8 21.9 172 BXRC-65E2001-D-7x 6500 80 500 2735 2461 31.8 15.9 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 117 BXRC-30A2001-B-73 3000 80 93 450 1806 1625 34.4 15.5 BXRC-30A2001-C-73 3000 80 93 630 2528 2275 34.4 21.6 117 BXRC-30A2001-D-73 3000 80 93 500 1834 1650 31.2 15.6 118 124 BXRC-35A2001-B-73 3500 80 93 450 1922 1730 34.4 15.5 BXRC-35A2001-C-73 3500 80 93 630 2691 2422 34.4 21.6 124 BXRC-35A2001-D-73 3500 80 93 500 1952 1757 31.2 15.6 125 BXRC-40A2001-B-73 4000 80 93 450 2083 1874 34.4 15.5 135 BXRC-40A2001-C-73 4000 80 93 630 2916 2624 34.4 21.6 135 BXRC-40A2001-D-73 4000 80 93 500 2115 1903 31.2 15.6 136 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-27E2000-B-7x 2700 80 450 2255 2030 33.9 15.3 148 BXRC-27E2000-C-7x 2700 80 630 3157 2841 33.9 21.4 148 BXRC-27E2000-D-7x 2700 80 500 2290 2061 30.9 15.5 148 BXRC-27G20H0-B-7x 2700 90 450 1931 1738 33.9 15.3 127 BXRC-27G20H0-C-7x 2700 90 630 2703 2433 33.9 21.4 127 BXRC-27G20H0-D-7x 2700 90 500 1960 1764 30.9 15.5 127 BXRC-27G2000-B-7x 2700 90 450 1860 1674 33.9 15.3 122 BXRC-27G2000-C-7x 2700 90 630 2605 2344 33.9 21.4 122 BXRC-27G2000-D-7x 2700 90 500 1889 1700 30.9 15.5 122 BXRC-27H2000-B-7x 2700 97 450 1649 1484 33.9 15.3 108 BXRC-27H2000-C-7x 2700 97 630 2309 2078 33.9 21.4 108 BXRC-27H2000-D-7x 2700 97 500 1674 1507 30.9 15.5 108 BXRC-30C2001-B-74 3000 70 450 2509 2258 33.9 15.3 164 BXRC-30C2001-C-74 3000 70 630 3512 3161 33.9 21.4 164 BXRC-30C2001-D-74 3000 70 500 2547 2292 30.9 15.5 165 BXRC-30E2000-B-7x 3000 80 450 2396 2156 33.9 15.3 157 BXRC-30E2000-C-7x 3000 80 630 3354 3019 33.9 21.4 157 BXRC-30E2000-D-7x 3000 80 500 2433 2189 30.9 15.5 157 BXRC-30G20H0-B-7x 3000 90 450 2030 1827 33.9 15.3 133 BXRC-30G20H0-C-7x 3000 90 630 2841 2557 33.9 21.4 133 BXRC-30G20H0-D-7x 3000 90 500 2061 1855 30.9 15.5 133 BXRC-30G2000-B-7x 3000 90 450 1945 1750 33.9 15.3 127 BXRC-30G2000-C-7x 3000 90 630 2723 2451 33.9 21.4 127 BXRC-30G2000-D-7x 3000 90 500 1975 1777 30.9 15.5 128 BXRC-30G200C-B-73 3000 90 450 1885 1697 34.1 15.3 123 BXRC-30G200C-D-73 3000 90 500 1903 1713 30.9 15.5 123 BXRC-30H2000-B-7x 3000 97 450 1762 1586 33.9 15.3 115 BXRC-30H2000-C-7x 3000 97 630 2466 2220 33.9 21.4 115 BXRC-30H2000-D-7x 3000 97 500 1789 1610 30.9 15.5 116 BXRC-30A2001-B-7x7,8 3000 93 450 1748 1573 33.9 15.3 115 BXRC-30A2001-C-7x7,8 3000 93 630 2447 2202 33.9 21.4 115 BXRC-30A2001-D-7x7,8 3000 93 500 1774 1597 30.9 15.5 115 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E2000-B-7x 3500 80 450 2452 2207 33.9 15.3 161 BXRC-35E2000-C-7x 3500 80 630 3433 3090 33.9 21.4 161 BXRC-35E2000-D-7x 3500 80 500 2490 2241 30.9 15.5 161 BXRC-35G2000-B-7x 3500 90 450 2015 1814 33.9 15.3 132 BXRC-35G2000-C-7x 3500 90 630 2822 2539 33.9 21.4 132 BXRC-35G2000-D-7x 3500 90 500 2046 1842 30.9 15.5 132 BXRC-35A2001-B-737,8 3500 93 450 1860 1674 33.9 15.3 122 BXRC-35A2001-C-737,8 3500 93 630 2605 2344 33.9 21.4 122 BXRC-35A2001-D-737,8 3500 93 500 1889 1700 30.9 15.5 122 BXRC-40C2001-B-74 4000 70 450 2579 2321 33.9 15.3 169 BXRC-40C2001-C-74 4000 70 630 3611 3250 33.9 21.4 169 BXRC-40C2001-D-74 4000 70 500 2619 2357 30.9 15.5 169 BXRC-40E2000-B-7x 4000 80 450 2466 2220 33.9 15.3 162 BXRC-40E2000-C-7x 4000 80 630 3453 3108 33.9 21.4 162 BXRC-40E2000-D-7x 4000 80 500 2504 2254 30.9 15.5 162 BXRC-40G2000-B-7x 4000 90 450 2058 1852 33.9 15.3 135 BXRC-40G2000-C-7x 4000 90 630 2881 2593 33.9 21.4 135 BXRC-40G2000-D-7x 4000 90 500 2089 1880 30.9 15.5 135 BXRC-40H2000-B-73 4000 97 450 1860 1674 33.9 15.3 122 BXRC-40H2000-C-73 4000 97 630 2605 2344 33.9 21.4 122 BXRC-40H2000-D-73 4000 97 500 1889 1700 30.9 15.5 122 BXRC-40A2001-B-737,8 4000 93 450 2015 1814 33.9 15.3 132 132 BXRC-40A2001-C-737,8 4000 93 630 2822 2539 33.9 21.4 BXRC-40A2001-D-737,8 4000 93 500 2046 1842 30.9 15.5 132 BXRC-50C2001-B-7x 5000 70 450 2593 2334 33.9 15.3 170 BXRC-50C2001-C-7x 5000 70 630 3631 3268 33.9 21.4 170 BXRC-50C2001-D-7x 5000 70 500 2633 2370 30.9 15.5 170 BXRC-50E2001-B-7x 5000 80 450 2495 2245 33.9 15.3 164 BXRC-50E2001-C-7x 5000 80 630 3492 3143 33.9 21.4 164 BXRC-50E2001-D-7x 5000 80 500 2533 2280 30.9 15.5 164 BXRC-50G2001-B-7x 5000 90 450 2156 1941 33.9 15.3 141 BXRC-50G2001-C-7x 5000 90 630 3019 2717 33.9 21.4 141 BXRC-50G2001-D-7x 5000 90 500 2189 1970 30.9 15.5 142 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 165 BXRC-57C2001-B-7x 5700 70 450 2523 2271 33.9 15.3 BXRC-57C2001-C-7x 5700 70 630 3532 3179 33.9 21.4 165 BXRC-57C2001-D-7x 5700 70 500 2561 2305 30.9 15.5 166 BXRC-57E2001-B-7x 5700 80 450 2396 2156 33.9 15.3 157 BXRC-57E2001-C-7x 5700 80 630 3354 3019 33.9 21.4 157 BXRC-57E2001-D-7x 5700 80 500 2433 2189 30.9 15.5 157 BXRC-65C2001-B-7x 6500 70 450 2523 2271 33.9 15.3 165 BXRC-65C2001-C-7x 6500 70 630 3532 3179 33.9 21.4 165 BXRC-65C2001-D-7x 6500 70 500 2561 2305 30.9 15.5 166 BXRC-65E2001-B-7x 6500 80 450 2424 2182 33.9 15.3 159 BXRC-65E2001-C-7x 6500 80 630 3394 3054 33.9 21.4 159 BXRC-65E2001-D-7x 6500 80 500 2461 2215 30.9 15.5 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-27E2000-B-7x 80 BXRC-27E2000-C-7x 80 BXRC-27E2000-D-7x 80 BXRC-27G20H0-B-7x 90 BXRC-27G20H0-C-7x 90 BXRC-27G20H0-D-7x 90 BXRC-27G2000-B-7x 90 BXRC-27G2000-C-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 682 1321 2506 3621 4619 948 1835 3508 5035 6426 673 1305 2544 3595 4597 584 1131 2145 3100 3955 812 1571 3004 4311 5502 577 1118 2178 3078 3936 563 1090 2067 2987 3811 782 1514 2894 4154 5301 625 1198 2255 3171 3967 896 1728 3157 4707 5987 643 1243 2290 3406 4344 535 1026 1931 2715 3397 767 1479 2703 4030 5127 551 1065 1960 2916 3719 516 988 1860 2616 3273 739 1425 2605 3883 4940 183 173 160 151 142 181 171 160 150 141 182 172 160 144 134 156 148 137 129 122 155 147 137 128 121 156 147 137 124 114 151 142 132 124 117 149 141 132 123 116 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G2000-D-7x 90 BXRC-27H2000-B-7x 97 BXRC-27H2000-C-7x 97 BXRC-27H2000-D-7x 97 BXRC-30C2001-B-74 70 BXRC-30C2001-C-74 70 BXRC-30C2001-D-74 70 BXRC-30E2000-B-7x 80 BXRC-30E2000-C-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 556 1077 2099 2966 3792 499 966 1832 2648 3378 693 1342 2565 3682 4699 492 955 1860 2629 3361 759 1469 2787 4028 5138 1054 2041 3902 5601 7149 749 1452 2830 3999 5114 725 1403 2662 3847 4907 1007 1949 3727 5349 6828 531 1026 1889 2810 3584 457 876 1649 2319 2901 655 1263 2309 3442 4378 470 909 1674 2490 3176 696 1333 2509 3528 4414 997 1922 3512 5236 6661 716 1383 2547 3789 4833 664 1273 2396 3369 4215 952 1836 3354 5001 6362 150 142 132 119 110 134 126 117 110 104 132 125 117 109 103 133 126 117 106 98 203 192 178 167 158 202 191 178 166 157 203 191 178 161 149 194 183 170 160 151 193 182 170 159 150 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E2000-D-7x 80 BXRC-30G20H0-B-7x 90 BXRC-30G20H0-C-7x 90 BXRC-30G20H0-D-7x 90 BXRC-30G2000-B-7x 90 BXRC-30G2000-C-7x 90 BXRC-30G2000-D-7x 90 BXRC-30G200C-B-73 90 BXRC-30G200C-D-73 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 125 250 500 750 1000 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 3.7 7.6 15.9 24.9 34.4 716 1387 2703 3820 4884 614 1189 2255 3259 4157 853 1651 3157 4531 5783 606 1175 2290 3236 4137 589 1139 2161 3123 3984 817 1583 3026 4343 5542 581 1126 2194 3101 3965 570 1104 2095 3027 3861 560 1085 2115 2988 3821 683 1321 2433 3619 4615 563 1078 2030 2854 3571 806 1555 2841 4236 5389 579 1119 2061 3065 3909 539 1033 1945 2735 3422 773 1490 2723 4060 5164 555 1072 1975 2937 3747 523 1001 1885 2651 3317 535 1034 1903 2831 3611 194 183 170 153 142 164 155 144 135 128 163 154 144 135 127 164 155 144 130 120 158 149 138 130 122 156 148 138 129 122 157 148 138 125 115 153 144 134 126 119 152 143 133 120 111 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30H2000-B-7x 97 BXRC-30H2000-C-7x 97 BXRC-30H2000-D-7x 97 BXRC-30A2001-B-73 93 BXRC-30A2001-C-73 93 BXRC-30A2001-D-73 93 BXRC-35E2000-B-7x 80 BXRC-35E2000-C-7x 80 BXRC-35E2000-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 533 1032 1958 2829 3608 740 1433 2741 3933 5020 526 1020 1988 2809 3591 529 1024 1942 2806 3580 735 1422 2719 3902 4980 522 1012 1972 2786 3562 742 1436 2725 3938 5023 1031 1995 3815 5475 6988 732 1420 2767 3910 4999 489 936 1762 2477 3100 700 1350 2466 3677 4678 502 971 1789 2661 3394 485 928 1748 2458 3075 694 1339 2447 3648 4640 498 964 1774 2639 3367 680 1303 2452 3449 4315 974 1879 3433 5119 6511 699 1352 2490 3704 4724 143 135 125 118 111 142 134 125 117 110 142 134 125 113 104 142 134 124 117 110 140 133 124 116 109 141 133 124 112 103 199 188 174 164 154 197 186 174 163 153 198 187 174 157 145 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35G2000-B-7x 90 BXRC-35G2000-C-7x 90 BXRC-35G2000-D-7x 90 BXRC-35A2001-B-73 93 BXRC-35A2001-C-73 93 BXRC-35A2001-D-73 93 BXRC-40C2001-B-74 70 BXRC-40C2001-C-74 70 BXRC-40C2001-D-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 610 1180 2239 3236 4128 847 1640 3135 4500 5743 602 1167 2274 3213 4108 563 1090 2067 2987 3811 782 1514 2894 4154 5301 556 1077 2099 2966 3792 780 1511 2866 4141 5283 1084 2099 4012 5759 7350 770 1493 2910 4112 5258 559 1071 2015 2834 3546 801 1544 2822 4207 5351 575 1111 2046 3044 3882 516 988 1860 2616 3273 739 1425 2605 3883 4940 531 1026 1889 2810 3584 715 1370 2579 3627 4538 1025 1976 3611 5383 6848 736 1422 2619 3895 4968 163 154 143 135 127 162 153 143 134 126 163 154 143 129 119 151 142 132 124 117 149 141 132 123 116 150 142 132 119 110 209 197 183 172 162 207 196 183 171 161 209 197 183 165 153 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40E2000-B-7x 80 BXRC-40E2000-C-7x 80 BXRC-40E2000-D-7x 80 BXRC-40G2000-B-7x 90 BXRC-40G2000-C-7x 90 BXRC-40G2000-D-7x 90 BXRC-40H2000-B-7x 97 BXRC-40H2000-C-7x 97 BXRC-40H2000-D-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 746 1445 2741 3960 5052 1037 2007 3837 5507 7028 737 1428 2783 3932 5028 623 1205 2286 3304 4215 865 1674 3201 4594 5864 615 1191 2321 3280 4195 563 1090 2067 2987 3811 782 1514 2894 4154 5301 556 1077 2099 2966 3792 684 1310 2466 3468 4339 980 1890 3453 5148 6549 703 1360 2504 3725 4751 571 1093 2058 2894 3620 818 1577 2881 4295 5464 587 1135 2089 3108 3964 516 988 1860 2616 3273 739 1425 2605 3883 4940 531 1026 1889 2810 3584 200 189 175 165 155 198 187 175 164 154 199 188 175 158 146 167 158 146 137 130 165 156 146 136 129 166 157 146 132 122 151 142 132 124 117 149 141 132 123 116 150 142 132 119 110 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A2001-B-73 93 BXRC-40A2001-C-73 93 BXRC-40A2001-D-73 93 BXRC-50C2001-B-7x 70 BXRC-50C2001-C-7x 70 BXRC-50C2001-D-7x 70 BXRC-50E2001-B-7x 80 BXRC-50E2001-C-7x 80 BXRC-50E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 610 1180 2239 3236 4128 847 1640 3135 4500 5743 602 1167 2274 3213 4108 785 1519 2881 4164 5312 1090 2110 4034 5790 7390 774 1501 2926 4134 5286 755 1461 2772 4006 5110 1048 2030 3881 5570 7109 745 1444 2814 3977 5085 559 1071 2015 2834 3546 801 1544 2822 4207 5351 575 1111 2046 3044 3882 719 1378 2593 3647 4562 1030 1987 3631 5413 6886 740 1430 2633 3917 4995 692 1325 2495 3508 4389 991 1911 3492 5207 6624 711 1375 2533 3768 4805 163 154 143 135 127 162 153 143 134 126 163 154 143 129 119 210 199 184 173 163 208 197 184 172 162 210 198 184 166 154 202 191 177 167 157 200 189 177 165 156 202 190 177 160 148 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G2001-B-7x 90 BXRC-50G2001-C-7x 90 BXRC-50G2001-D-7x 90 BXRC-57C2001-B-7x 70 BXRC-57C2001-C-7x 70 BXRC-57C2001-D-7x 70 BXRC-57E2001-B-7x 80 BXRC-57E2001-C-7x 80 BXRC-57E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 653 1263 2396 3463 4417 906 1755 3354 4815 6145 644 1248 2433 3438 4396 763 1478 2803 4051 5167 1060 2053 3924 5633 7189 753 1460 2846 4022 5143 725 1403 2662 3847 4907 1007 1949 3727 5349 6828 716 1387 2703 3820 4884 598 1145 2156 3032 3794 857 1652 3019 4501 5726 615 1189 2189 3257 4154 700 1340 2523 3548 4438 1002 1933 3532 5266 6698 720 1391 2561 3810 4860 664 1273 2396 3369 4215 952 1836 3354 5001 6362 683 1321 2433 3619 4615 175 165 153 144 136 173 164 153 143 135 174 165 153 138 128 204 193 179 168 159 203 192 179 167 158 204 193 179 162 149 194 183 170 160 151 193 182 170 159 150 194 183 170 153 142 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-65C2001-B-7x 70 BXRC-65C2001-C-7x 70 BXRC-65C2001-D-7x 70 BXRC-65E2001-B-7x 80 BXRC-65E2001-C-7x 80 BXRC-65E2001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 113 225 450 675 900 158 315 630 945 1260 125 250 500 750 1000 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 29.6 30.3 31.8 33.2 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 3.7 7.7 15.7 24.1 32.5 5.2 10.7 21.9 33.7 45.5 3.7 7.6 15.9 24.9 34.4 763 1478 2803 4051 5167 1060 2053 3924 5633 7189 753 1460 2846 4022 5143 734 1420 2694 3893 4965 1019 1972 3771 5412 6908 724 1403 2735 3865 4942 700 1340 2523 3548 4438 1002 1933 3532 5266 6698 720 1391 2561 3810 4860 672 1288 2424 3409 4265 963 1857 3394 5060 6437 691 1337 2461 3661 4670 204 193 179 168 159 203 192 179 167 158 204 193 179 162 149 196 186 172 162 153 195 184 172 161 152 196 185 172 155 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.28 31.0 38.3 -14.3 0.35 32.2 39.7 37.4 -14.3 0.20 31.0 38.3 36.1 38.8 -14.3 0.24 32.2 39.7 29.4 31.8 34.2 -13.3 0.34 28.4 35.0 31.8 34.4 37.0 -13.3 0.41 30.8 37.9 Minimum Typical Maximum 450 32.2 34.8 37.4 -14.3 900 33.4 36.1 38.8 630 32.2 34.8 1260 33.4 500 1000 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 19 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 450 RG1 RG1 RG1 RG1 675 RG1 RG1 RG1 RG2 900 RG1 RG1 RG2 RG2 630 RG1 RG1 RG1 RG1 945 RG1 RG1 RG2 RG2 1260 RG1 RG2 RG2 RG2 500 RG1 RG1 RG1 RG1 750 RG1 RG1 RG1 RG2 1000 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 20 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx200x-B-7x BXRC-xxx200x-C-7x BXRC-xxx200x-D-7x Maximum Drive Current3 900mA 1260mA 1000mA Maximum Peak Pulsed Drive Current4 1290mA 1800mA 1430mA Maximum Reverse Voltage5 -60V -60V -55V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 21 Performance Curves Figure 1: Vero 13B Drive Current vs. Voltage Figure 2: Vero 13C Drive Current vs. Voltage 1000 1400 900 1200 700 Forward Current (mA) Forward Current (mA) 800 600 500 400 300 1000 800 600 400 200 200 100 0 32 33 34 35 36 37 0 38 32 33 34 Forward Voltage (V) 35 36 37 38 Forward Voltage (V) Figure 3: Vero 13D Drive Current vs. Voltage Figure 4: Vero 13B Typical Relative Flux vs. Current 200% 1100 180% 1000 160% Relative Luminous Flux Forward Current (mA) 900 800 700 600 500 400 300 120% 100% 80% 60% 40% 200 20% 100 0 140% 0% 29 30 31 32 33 34 0 35 100 200 300 200% 200% 180% 180% 160% 160% 140% 140% 120% 100% 80% 60% 850 Forward Current (mA) 900 1000 60% 20% 0% 700 800 80% 40% 550 700 100% 20% 400 600 120% 40% 250 500 Figure 6 Vero 13D Typical Relative Flux vs. Current Relative Luminous Flux Relative Luminous Flux Figure 5: Vero 13C Typical Relative Flux vs. Current 100 400 Forward Current (mA) Forward Voltage (V) 1000 1150 1300 0% 0 100 200 300 400 500 600 700 800 900 1000 1100 Forward Current (mA) Note for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 22 Performance Curves Figure 7: Typical DC Flux vs. Case Temperature 0 103% 25 50 75 100 125 0.003 Warm White Neutral White 100% Cool White 0.000 25°C Pulsed 97% -0.003 94% ccy Shift Relative Luminous Flux Figure 8: Typical DC ccy Shift vs. Case Temperature 91% -0.006 88% -0.009 85% -0.012 Warm White 82% 0 25 50 75 100 125 Case Temperature (°C) -0.015 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Figure 9: Typical DC ccx Shift vs. Case Temperature 0 25 50 75 100 125 0.000 -0.002 ccx Shift -0.004 -0.006 -0.008 Warm White -0.010 -0.012 Neutral White Cool White 25°C Pulsed Case Temperature (°C) Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 23 Performance Curves Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 25°C 45°C 0.4010 45°C ccy ccy 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 0.4090 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.4572 0.4574 0.4576 0.4578 0.3950 0.4323 0.458 0.4328 0.4333 ccx Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature3 0.4343 0.369 15°C 0.402 Pulsed Center Point Tc=25°C 25°C 15°C 0.368 25°C 0.367 0.401 0.366 0.399 ccy 45°C 0.4 0.4348 0.4353 Figure 13: 3000K Class A Color Shift vs. Case Temperature1 0.403 ccy 0.4338 ccx 65°C 0.398 45°C 0.365 0.364 70°C 0.363 85°C 0.397 Pulsed Center Point Tc=25°C 85°C 0.362 105°C 0.396 0.395 0.444 0.361 0.4445 0.445 0.4455 0.446 0.4465 105°C 0.36 0.416 0.447 0.4165 0.417 ccx 0.4175 0.418 0.4185 ccx Figure 14: 3500K Class A Color Shift vs. Case Temperature1 Figure 15: 4000K Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 25°C 0.366 Pulsed Center Point Tc=25°C 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 70°C 0.3660 85°C 0.36 85°C 0.3640 105°C 0.358 0.392 105°C 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 10-15: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G200C-x-73 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 24 Typical Radiation Pattern Figure 16: Typical Spatial Radiation Pattern Note for Figure 16: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 17: Typical Polar Radiation Pattern 25 Typical Color Spectrum Figure 18: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 18: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 19: Typical Color Spectrum for Vero 13 with Décor Series 1 27H 0.9 30H 30G (Décor Series Showcase) Relative Spectral Power Distribution 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 19: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 26 Mechanical Dimensions Figure 20: Drawing for Vero 13 LED Array Notes for Figure 20: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ±0.1mm. 4. Mounting holes (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 27 Color Binning Information Figure 21: Warm and Neutral White Test Bins in xy Color Figure 22: Cool White Test Bins in xy Color Space Space 0.44 0.39 4 SDCM 3 SDCM 3 SDCM 0.38 2 SDCM 2700K 0.42 0.37 3000K 0.4 5000K 0.36 3500K 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 X 0.45 0.3 0.48 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 28 Packaging and Labeling Figure 23: Drawing for Vero 13 Packaging Tray Notes for Figure 23: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 29 Packaging and Labeling Figure 24: Vero Series Packaging and Labeling Notes for Figure 24: 1. Each tray holds 100 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 25: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E2000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 31 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserve. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. V Bridgelux Gen 7 Vero 13 Array Series Product Data Sheet DS91 Rev. P (03/2019) 32
BXRC-40E2000-B-73 价格&库存

很抱歉,暂时无法提供与“BXRC-40E2000-B-73”相匹配的价格&库存,您可以联系我们找货

免费人工找货
BXRC-40E2000-B-73
    •  国内价格
    • 1+8.06073

    库存:78