Bridgelux Vero SE 18 Array
®
®
Product Data Sheet DS122
1
Vero SE
Introduction
Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with
poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower
manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility.
Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range.
With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into
fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control
and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting.
Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series
color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and a minimum R9 value of 93, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is also a good replacement for halogen lamps.
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher efficacy.
Features
• Poke-in connectivity
• Efficacy of 157 lm/W typical
• Lumen output performance ranges from 1,372 to
13,060 lumens
Benefits
• Poke-in connectivity enables solderless, connector
free installation
• Broad application coverage for interior and exterior
lighting
• Broad range of CCT options from 1750K to 6500K
• Flexibility for application driven lighting design
requirements
• CRI options: minimum 65, 70, 80, and 90
• High quality, true color reproduction
• Color control: 2 and 3 SDCM for 2700K-4000K CCT
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Top side part number markings
• Ability to configure multiple Vero SE arrays in series
and parallel reduces customer driver cost
• No exposed solder pads or electrical connections
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
20
Eye Safety
21
Absolute Maximum Ratings
22
Performance Curves
23
Typical Radiation Pattern
27
Typical Color Spectrum
28
Mechanical Dimensions
29
Color Binning Information
30
Packaging and Labeling
31
Design Resources
33
Precautions
33
Disclaimers
33
About Bridgelux
34
1
Product Feature Map
Vero SE 18 is the second largest form factor in the
product family of next generation solid state light
sources. In addition to delivering the performance and
light quality required for many lighting applications,
Vero SE incorporates several features to simplify the
design integration and manufacturing process, accelerate
time to market and reduce system costs. Please visit www.
bridgelux.com for more information on the Vero SE family
of products.
2D Bar code provides full
manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Wire release mechanisms x4
Tc Measurement point
Optic mounting holes
Radial die configuration improves lumen
density and beam control
Mounting holes
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Test ports for probing
Dual poke-in connectivity
Product Nomenclature
The part number designation for Bridgelux Vero SE LED arrays is explained as follows:
1 2 3 4
–
5 6 7 8 9 10 11
– 12
– 13 14
– 15 16
BXRC – 30 E 400 0 – C – 7 3 – SE
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Special Edition
CCT Bin Options
Gen. 7
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
400x = 4000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
80
900
2725
2452
80
1170
3542
3188
Part Number
Nominal
CCT1
(K)
CRI2
BXRC-17E4000-B-74-SE
1750
BXRC-17E4000-C-74-SE
1750
Typical
Power
(W)
Typical
Efficacy
(lm/W)
34.8
31.3
87
34.8
40.7
87
BXRC-17E4000-D-74-SE
1750
80
1050
2649
2384
29.0
30.5
87
BXRC-20B4001-C-73-SE
2000
65
1170
5985
5387
34.8
40.7
147
BXRC-20B4001-D-73-SE
2000
65
1050
4476
4029
29.0
30.5
147
BXRC-25E4000-B-74-SE
2500
80
900
4416
3975
34.8
31.3
141
BXRC-25E4000-C-74-SE
2500
80
1170
5741
5167
34.8
40.7
141
BXRC-25E4000-D-74-SE
2500
80
1050
4293
3864
29.0
30.5
141
BXRC-27E4000-B-7x-SE
2700
80
900
4729
4256
34.8
31.3
151
151
BXRC-27E4000-C-7x-SE
2700
80
1170
6148
5533
34.8
40.7
BXRC-27E4000-D-7x-SE
2700
80
1050
4598
4138
29.0
30.5
151
BXRC-27G40H0-B-7x-SE
2700
90
900
4072
3664
34.8
31.3
130
BXRC-27G40H0-C-7x-SE
2700
90
1170
5293
4764
34.8
40.7
130
BXRC-27G40H0-D-7x-SE
2700
90
1050
3959
3563
29.0
30.5
130
BXRC-27G4000-B-7x-SE
2700
90
900
3946
3552
34.8
31.3
126
BXRC-27G4000-C-7x-SE
2700
90
1170
5130
4617
34.8
40.7
126
BXRC-27G4000-D-7x-SE
2700
90
1050
3837
3453
29.0
30.5
126
BXRC-27H4000-B-7x-SE
2700
97
900
3414
3072
34.8
31.3
109
BXRC-27H4000-C-7x-SE
2700
97
1170
4438
3994
34.8
40.7
109
BXRC-27H4000-D-7x-SE
2700
97
1050
3319
2987
29.0
30.5
109
BXRC-30C4001-B-74-SE
3000
70
900
5387
4848
34.8
31.3
172
BXRC-30C4001-C-74-SE
3000
70
1170
7003
6303
34.8
40.7
172
BXRC-30C4001-D-74-SE
3000
70
1050
5237
4714
29.0
30.5
172
BXRC-30E4000-B-7x-SE
3000
80
900
4917
4426
34.8
31.3
157
BXRC-30E4000-C-7x-SE
3000
80
1170
6392
5753
34.8
40.7
157
BXRC-30E4000-D-7x-SE
3000
80
1050
4781
4303
29.0
30.5
157
BXRC-30G40H0-B-7x-SE
3000
90
900
4291
3862
34.8
31.3
137
BXRC-30G40H0-C-7x-SE
3000
90
1170
5578
5020
34.8
40.7
137
BXRC-30G40H0-D-7x-SE
3000
90
1050
4172
3754
29.0
30.5
137
BXRC-30G4000-B-7x-SE
3000
90
900
4103
3693
34.8
31.3
131
BXRC-30G4000-C-7x-SE
3000
90
1170
5334
4800
34.8
40.7
131
BXRC-30G4000-D-7x-SE
3000
90
1050
3989
3590
29.0
30.5
131
BXRC-30G400C-B-73-SE
3000
90
900
3790
3411
34.8
31.3
121
BXRC-30G400C-D-73-SE
3000
90
1050
3684
3316
29.0
30.5
121
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products
is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-B-7x-SE
3000
97
900
3664
3298
34.8
31.3
117
BXRC-30H4000-C-7x-SE
3000
97
1170
4764
4287
34.8
40.7
117
BXRC-30H4000-D-7x-SE
3000
97
1050
3563
3206
29.0
30.5
117
BXRC-30A4001-B-73-SE8,9
3000
93
900
3696
3326
34.8
31.3
118
BXRC-30A4001-C-73-SE8,9
3000
93
1170
4804
4324
34.8
40.7
118
BXRC-30A4001-D-73-SE8,9
3000
93
1050
3593
3234
29.0
30.5
118
BXRC-35E4000-B-7x-SE
3500
80
900
5074
4566
34.8
31.3
162
BXRC-35E4000-C-7x-SE
3500
80
1170
6596
5936
34.8
40.7
162
BXRC-35E4000-D-7x-SE
3500
80
1050
4933
4440
29.0
30.5
162
BXRC-35G4000-B-7x-SE
3500
90
900
4228
3805
34.8
31.3
135
BXRC-35G4000-C-7x-SE
3500
90
1170
5497
4947
34.8
40.7
135
BXRC-35G4000-D-7x-SE
3500
90
1050
4111
3700
29.0
30.5
135
BXRC-35A4001-B-73-SE8,9
3500
93
900
3978
3580
34.8
31.3
127
BXRC-35A4001-C-73-SE8,9
3500
93
1170
5171
4654
34.8
40.7
127
BXRC-35A4001-D-73-SE8,9
3500
93
1050
3867
3480
29.0
30.5
127
BXRC-40C4001-B-74-SE
4000
90
900
5544
4989
34.8
31.3
177
177
BXRC-40C4001-C-74-SE
4000
90
1170
7207
6486
34.8
40.7
BXRC-40C4001-D-74-SE
4000
90
1050
5390
4851
29.0
30.5
177
BXRC-40E4000-B-7x-SE
4000
80
900
5105
4595
34.8
31.3
163
163
BXRC-40E4000-C-7x-SE
4000
80
1170
6637
5973
34.8
40.7
BXRC-40E4000-D-7x-SE
4000
80
1050
4963
4467
29.0
30.5
163
BXRC-40G4000-B-7x-SE
4000
90
900
4385
3946
34.8
31.3
140
BXRC-40G4000-C-7x-SE
4000
90
1170
5700
5130
34.8
40.7
140
BXRC-40G4000-D-7x-SE
4000
90
1050
4263
3837
29.0
30.5
140
BXRC-40H4000-B-7X-SE
4000
97
900
3758
3383
34.8
31.3
120
BXRC-40H4000-C-7X-SE
4000
97
1170
4886
4397
34.8
40.7
120
BXRC-40H4000-D-7X-SE
4000
97
1050
3654
3289
29.0
30.5
120
BXRC-40A4001-B-73-SE8,9
4000
93
900
4260
3834
34.8
31.3
136
BXRC-40A4001-C-73-SE8,9
4000
93
1170
5537
4984
34.8
40.7
136
BXRC-40A4001-D-73-SE8,9
4000
93
1050
4141
3727
29.0
30.5
136
BXRC-50C4001-B-7x-SE
5000
70
900
5606
5046
34.8
31.3
179
BXRC-50C4001-C-7x-SE
5000
70
1170
7288
6559
34.8
40.7
179
BXRC-50C4001-D-7x-SE
5000
70
1050
5451
4905
29.0
30.5
179
BXRC-50E4001-B-7x-SE
5000
80
900
5262
4736
34.8
31.3
168
BXRC-50E4001-C-7x-SE
5000
80
1170
6840
6156
34.8
40.7
168
BXRC-50E4001-D-7x-SE
5000
80
1050
5116
4604
29.0
30.5
168
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for
all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI
products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50G4001-B-7x-SE
5000
90
900
4479
4031
34.8
31.3
143
BXRC-50G4001-C-7x-SE
5000
90
1170
5822
5240
34.8
40.7
143
BXRC-50G4001-D-7x-SE
5000
90
1050
4354
3919
29.0
30.5
143
BXRC-56G4000-B-74-SE
5600
90
900
4698
4228
34.8
31.3
150
BXRC-56G4000-C-74-SE
5600
90
1170
6107
5497
34.8
40.7
150
BXRC-56G400x-D-74-SE
5600
90
1050
4568
4111
29.0
30.5
150
BXRC-56H4000-D-74-SE
5600
97
1050
3959
3563
29.0
30.5
130
BXRC-57C4001-B-7x-SE
5700
70
900
5418
4877
34.8
31.3
173
BXRC-57C4001-C-7x-SE
5700
70
1170
7044
6339
34.8
40.7
173
BXRC-57C4001-D-7x-SE
5700
70
1050
5268
4741
29.0
30.5
173
BXRC-57E4001-B-7x-SE
5700
80
900
5199
4679
34.8
31.3
166
BXRC-57E4001-C-7x-SE
5700
80
1170
6759
6083
34.8
40.7
166
BXRC-57E4001-D-7x-SE
5700
80
1050
5055
4549
29.0
30.5
166
BXRC-65C4001-B-7x-SE
6500
70
900
5512
4961
34.8
31.3
176
BXRC-65C4001-C-7x-SE
6500
70
1170
7166
6449
34.8
40.7
176
BXRC-65C4001-D-7x-SE
6500
70
1050
5359
4823
29.0
30.5
176
BXRC-65E4001-B-7x-SE
6500
80
900
5293
4764
34.8
31.3
169
BXRC-65E4001-C-7x-SE
6500
80
1170
6881
6193
34.8
40.7
169
BXRC-65E4001-D-7x-SE
6500
80
1050
5146
4631
29.0
30.5
169
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A4001-B-73-SE
3000
80
93
900
3437
3093
34.3
30.9
111
BXRC-30A4001-C-73-SE
3000
80
93
1170
4468
4021
34.3
40.2
111
BXRC-30A4001-D-73-SE
3000
80
93
1050
3342
3007
28.5
29.9
112
BXRC-35A4001-B-73-SE
3500
80
93
900
3699
3329
34.3
30.9
120
BXRC-35A4001-C-73-SE
3500
80
93
1170
4809
4328
34.3
40.2
120
BXRC-35A4001-D-73-SE
3500
80
93
1050
3596
3237
28.5
29.9
120
BXRC-40A4001-B-73-SE
4000
80
93
900
3961
3565
34.3
30.9
128
BXRC-40A4001-C-73-SE
4000
80
93
1170
5150
4635
34.3
40.2
128
BXRC-40A4001-D-73-SE
4000
80
93
1050
3851
3466
28.5
29.9
129
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E4000-B-74-SE
1750
80
900
2452
2207
33.9
30.5
80
BXRC-17E4000-C-74-SE
1750
80
1170
3188
2869
33.9
39.7
80
BXRC-17E4000-D-74-SE
1750
80
1050
2384
2146
28.3
29.7
80
BXRC-20B4001-C-73-SE
2000
65
1170
5387
4848
34.1
39.9
135
BXRC-20B4001-D-73-SE
2000
65
1050
4029
3626
28.3
29.7
136
BXRC-25E4000-B-74-SE
2500
80
900
3975
3577
33.9
30.5
130
BXRC-25E4000-C-74-SE
2500
80
1170
5167
4650
33.9
39.7
130
BXRC-25E4000-D-74-SE
2500
80
1050
3864
3478
28.3
29.7
130
BXRC-27E4000-B-7x-SE
2700
80
900
4256
3831
33.9
30.5
139
BXRC-27E4000-C-7x-SE
2700
80
1170
5533
4980
33.9
39.7
139
BXRC-27E4000-D-7x-SE
2700
80
1050
4138
3724
28.3
29.7
139
BXRC-27G40H0-B-7x-SE
2700
90
900
3664
3298
33.9
30.5
120
BXRC-27G40H0-C-7x-SE
2700
90
1170
4764
4287
33.9
39.7
120
BXRC-27G40H0-D-7x-SE
2700
90
1050
3563
3206
28.3
29.7
120
BXRC-27G4000-B-7x-SE
2700
90
900
3552
3197
33.9
30.5
116
BXRC-27G4000-C-7x-SE
2700
90
1170
4617
4155
33.9
39.7
116
BXRC-27G4000-D-7x-SE
2700
90
1050
3453
3108
28.3
29.7
116
BXRC-27H4000-B-7x-SE
2700
97
900
3072
2765
33.9
30.5
101
101
BXRC-27H4000-C-7x-SE
2700
97
1170
3994
3595
33.9
39.7
BXRC-27H4000-D-7x-SE
2700
97
1050
2987
2688
28.3
29.7
101
BXRC-30C4001-B-74-SE
3000
70
900
4848
4364
33.9
30.5
159
BXRC-30C4001-C-74-SE
3000
70
1170
6303
5673
33.9
39.7
159
BXRC-30C4001-D-74-SE
3000
70
1050
4714
4242
28.3
29.7
159
BXRC-30E4000-B-7x-SE
3000
80
900
4426
3983
33.9
30.5
145
BXRC-30E4000-C-7x-SE
3000
80
1170
5753
5178
33.9
39.7
145
BXRC-30E4000-D-7x-SE
3000
80
1050
4303
3872
28.3
29.7
145
BXRC-30G40H0-B-7x-SE
3000
90
900
3862
3476
33.9
30.5
127
BXRC-30G40H0-C-7x-SE
3000
90
1170
5020
4518
33.9
39.7
127
BXRC-30G40H0-D-7x-SE
3000
90
1050
3754
3379
28.3
29.7
126
BXRC-30G4000-B-7x-SE
3000
90
900
3693
3323
33.9
30.5
121
BXRC-30G4000-C-7x-SE
3000
90
1170
4800
4320
33.9
39.7
121
BXRC-30G4000-D-7x-SE
3000
90
1050
3590
3231
28.3
29.7
121
BXRC-30G400C-B-73-SE
3000
90
900
3411
3070
33.9
30.5
112
BXRC-30G400C-D-73-SE
3000
90
1050
3316
2984
28.3
29.7
112
BXRC-30H4000-B-7x-SE
3000
97
900
3298
2968
33.9
30.5
108
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-C-7x-SE
3000
97
1170
4287
3859
33.9
39.7
108
BXRC-30H4000-D-7x-SE
3000
97
1050
3206
2886
28.3
29.7
108
BXRC-30A4001-B-73-SE7,8
3000
93
900
3326
2994
33.9
30.5
109
BXRC-30A4001-C-73-SE7,8
3000
93
1170
4324
3892
33.9
39.7
109
BXRC-30A4001-D-73-SE7,8
3000
93
1050
3234
2910
28.3
29.7
109
BXRC-35E4000-B-7x-SE
3500
80
900
4566
4110
33.9
30.5
150
BXRC-35E4000-C-7x-SE
3500
80
1170
5936
5343
33.9
39.7
150
BXRC-35E4000-D-7x-SE
3500
80
1050
4440
3996
28.3
29.7
150
BXRC-35G4000-B-7x-SE
3500
90
900
3805
3425
33.9
30.5
125
BXRC-35G4000-C-7x-SE
3500
90
1170
4947
4452
33.9
39.7
125
BXRC-35G4000-D-7x-SE
3500
90
1050
3700
3330
28.3
29.7
125
BXRC-35A4001-B-73-SE7,8
3500
93
900
3580
3222
33.9
30.5
117
BXRC-35A4001-C-73-SE7,8
3500
93
1170
4654
4188
33.9
39.7
117
BXRC-35A4001-D-73-SE7,8
3500
93
1050
3480
3132
28.3
29.7
117
BXRC-40C4001-B-74-SE
4000
70
900
4989
4490
33.9
30.5
164
BXRC-40C4001-C-74-SE
4000
70
1170
6486
5837
33.9
39.7
164
BXRC-40C4001-D-74-SE
4000
70
1050
4851
4366
28.3
29.7
163
BXRC-40E4000-B-7x-SE
4000
80
900
4595
4135
33.9
30.5
151
BXRC-40E4000-C-7x-SE
4000
80
1170
5973
5376
33.9
39.7
151
BXRC-40E4000-D-7x-SE
4000
80
1050
4467
4020
28.3
29.7
150
BXRC-40G4000-B-7x-SE
4000
90
900
3946
3552
33.9
30.5
129
BXRC-40G4000-C-7x-SE
4000
90
1170
5130
4617
33.9
39.7
129
BXRC-40G4000-D-7x-SE
4000
90
1050
3837
3453
28.3
29.7
129
BXRC-40H4000-B-7X-SE
4000
97
900
3383
3044
33.9
30.5
111
BXRC-40H4000-C-7X-SE
4000
97
1170
4397
3958
33.9
39.7
111
BXRC-40H4000-D-7X-SE
4000
97
1050
3289
2960
28.3
29.7
111
BXRC-40A4001-B-73-SE7,8
4000
93
900
3834
3450
34.1
30.7
125
BXRC-40A4001-C-73-SE7,8
4000
93
1170
4984
4485
34.1
39.9
125
BXRC-40A4001-D-73-SE7,8
4000
93
1050
3727
3354
28.3
29.7
126
BXRC-50C4001-B-7x-SE
5000
70
900
5046
4541
34.1
30.7
165
BXRC-50C4001-C-7x-SE
5000
70
1170
6559
5903
34.1
39.9
165
BXRC-50C4001-D-7x-SE
5000
70
1050
4905
4415
28.3
29.7
165
BXRC-50E4001-B-7x-SE
5000
80
900
4736
4262
34.1
30.7
154
BXRC-50E4001-C-7x-SE
5000
80
1170
6156
5541
34.1
39.9
154
BXRC-50E4001-D-7x-SE
5000
80
1050
4604
4144
28.3
29.7
155
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50,
the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
131
BXRC-50G4001-B-7x-SE
5000
90
900
4031
3628
34.1
30.7
BXRC-50G4001-C-7x-SE
5000
90
1170
5240
4716
34.1
39.9
131
BXRC-50G4001-D-7x-SE
5000
90
1050
3919
3527
28.3
29.7
132
BXRC-56G4000-B-74-SE
5600
90
900
4228
3805
34.1
30.7
138
BXRC-56G4000-C-74-SE
5600
90
1170
5497
4947
34.1
39.9
138
BXRC-56G400x-D-74-SE
5600
90
1050
4111
3700
28.3
29.7
138
BXRC-56H4000-D-74-SE
5600
97
1050
3563
3206
28.3
29.7
120
159
BXRC-57C4001-B-7x-SE
5700
80
900
4877
4389
34.1
30.7
BXRC-57C4001-C-7x-SE
5700
80
1170
6339
5706
34.1
39.9
159
BXRC-57C4001-D-7x-SE
5700
80
1050
4741
4267
28.3
29.7
160
BXRC-57E4001-B-7x-SE
5700
80
900
4679
4211
34.1
30.7
153
BXRC-57E4001-C-7x-SE
5700
80
1170
6083
5475
34.1
39.9
153
BXRC-57E4001-D-7x-SE
5700
80
1050
4549
4094
28.3
29.7
153
BXRC-65C4001-B-7x-SE
6500
70
900
4961
4465
34.1
30.7
162
BXRC-65C4001-C-7x-SE
6500
70
1170
6449
5804
34.1
39.9
162
BXRC-65C4001-D-7x-SE
6500
70
1050
4823
4341
28.3
29.7
163
155
BXRC-65E4001-B-7x-SE
6500
80
900
4764
4287
34.1
30.7
BXRC-65E4001-C-7x-SE
6500
80
1170
6193
5574
34.1
39.9
155
BXRC-65E4001-D-7x-SE
6500
80
1050
4631
4168
28.3
29.7
156
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 98.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E4000-B-74-SE
80
BXRC-17E4000-C-74-SE
80
BXRC-17E4000-D-74-SE
80
BXRC-20B4001-C-73-SE
65
BXRC-20B4001-D-73-SE
65
BXRC-25E4000-B-74-SE
80
BXRC-25E4000-C-74-SE
80
BXRC-25E4000-D-74-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
1463
1919
2725
4053
5215
1851
2425
3542
5096
6537
1411
1835
2649
3784
4817
3127
4098
5985
8610
11045
2384
3101
4476
6394
8139
2371
3110
4416
6568
8452
3000
3931
5741
8259
10594
2287
2974
4293
6133
1315
1721
2452
3571
4533
1752
2248
3188
4485
5634
1310
1682
2384
3346
4189
2960
3798
5387
7579
9519
2213
2841
4029
5654
7078
2131
2790
3975
5787
7347
2839
3643
5167
7269
9131
2123
2725
3864
5423
98
95
87
82
77
95
92
87
79
74
97
93
87
79
73
161
155
147
134
124
164
157
147
133
123
159
154
141
133
124
155
149
141
129
119
157
151
141
128
2100
31.5
66.2
7807
6789
118
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E4000-B-7x-SE
80
BXRC-27E4000-C-7x-SE
80
BXRC-27E4000-D-7x-SE
80
BXRC-27G40H0-B-7x-SE
90
BXRC-27G40H0-C-7x-SE
90
BXRC-27G40H0-D-7x-SE
90
BXRC-27G4000-B-7x-SE
90
BXRC-27G4000-C-7x-SE
90
BXRC-27G4000-D-7x-SE
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
2539
3331
4729
7034
9051
3212
4209
6148
8845
11345
2449
3185
4598
6568
8360
2186
2868
4072
6056
7793
2766
3624
5293
7615
9767
2109
2742
3959
5654
7198
2119
2779
3946
5869
7553
2680
3513
5130
7380
9467
2044
2658
3837
5480
6976
2282
2988
4256
6198
7868
3040
3901
5533
7785
9778
2273
2919
4138
5807
7270
1964
2572
3664
5336
6774
2617
3358
4764
6702
8418
1957
2513
3563
5000
6259
1904
2493
3552
5171
6565
2537
3255
4617
6496
8159
1897
2436
3453
4846
6067
170
164
151
143
133
166
160
151
138
128
168
161
151
137
126
147
142
130
123
115
142
137
130
119
110
145
139
130
118
109
142
137
126
119
111
138
133
126
115
107
140
135
126
114
105
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27H4000-B-7x-SE
80
BXRC-27H4000-C-7x-SE
80
BXRC-27H4000-D-7x-SE
80
BXRC-30C4001-B-74-SE
70
BXRC-30C4001-C-74-SE
70
BXRC-30C4001-D-74-SE
70
BXRC-30E4000-B-7x-SE
80
BXRC-30E4000-C-7x-SE
80
BXRC-30E4000-D-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
1833
2404
3414
5077
6534
2319
3039
4438
6385
8190
1768
2299
3319
4741
6035
2892
3794
5387
8012
1647
2157
3072
4474
5680
2194
2816
3994
5619
7059
1641
2107
2987
4192
5248
2599
3403
4848
7059
123
119
109
103
96
119
115
109
100
92
121
116
109
99
91
194
187
172
163
1800
37.8
68.1
10310
8962
151
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
3659
4795
7003
10075
12923
2790
3628
5237
7481
9523
2640
3463
4917
7313
3463
4443
6303
8867
11138
2590
3325
4714
6615
8281
2372
3106
4426
6444
189
182
172
157
146
192
184
172
156
144
177
171
157
149
1800
37.8
68.1
9411
8181
138
585
780
1170
1755
2340
525
700
1050
1575
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
3340
4377
6392
9196
11796
2547
3312
4781
6828
3161
4056
5753
8094
10167
2364
3035
4303
6038
172
166
157
143
133
175
168
157
142
2100
31.5
66.2
8693
7559
131
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G40H0-B-7x-SE
90
BXRC-30G40H0-C-7x-SE
90
BXRC-30G40H0-D-7x-SE
90
BXRC-30G4000-B-7x-SE
90
BXRC-30G4000-C-7x-SE
90
BXRC-30G4000-D-7x-SE
90
BXRC-30G400C-B-73-SE
90
BXRC-30G400C-D-73-SE
90
BXRC-30H4000-B-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
525
700
1050
1575
2100
450
600
900
1350
1800
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
2304
3022
4291
6382
8212
2914
3819
5578
8025
10293
2222
2890
4172
5959
7585
2203
2890
4103
6102
7853
2787
3652
5334
7673
9843
2125
2763
3989
5698
7253
2035
2669
3790
5636
7253
1963
2552
3684
5263
6699
1967
2581
3664
5450
7013
2070
2711
3862
5623
7139
2758
3539
5020
7063
8872
2063
2648
3754
5269
6596
1979
2592
3693
5377
6826
2637
3384
4800
6754
8483
1972
2532
3590
5038
6307
1828
2394
3411
4966
6305
1822
2339
3316
4654
5826
1768
2315
3298
4802
6097
154
149
137
130
121
150
145
137
125
116
153
146
137
124
115
148
143
131
124
115
144
139
131
120
111
146
140
131
119
110
136
132
121
115
107
135
129
121
110
101
132
127
117
111
103
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30H4000-C-7x-SE
80
BXRC-30H4000-D-7x-SE
80
BXRC-30A4001-B-73-SE
93
BXRC-30A4001-C-73-SE
93
BXRC-30A4001-D-73-SE
93
BXRC-35E4000-B-7x-SE
80
BXRC-35E4000-C-7x-SE
80
BXRC-35E4000-D-7x-SE
80
BXRC-35G4000-B-7x-SE
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
2489
3262
4764
6853
8791
1898
2468
3563
5089
6478
1984
2603
3696
5497
7073
2510
3290
4804
6912
8866
1914
2489
3593
5132
6533
2724
3574
5074
7546
9711
3446
4516
6596
9489
12172
2628
3417
4933
7046
8969
2270
2978
4228
6289
8092
2356
3023
4287
6032
7577
1762
2262
3206
4500
5633
1783
2335
3326
4843
6149
2376
3048
4324
6083
7641
1777
2281
3234
4538
5681
2448
3205
4566
6649
8441
3261
4185
5936
8352
10491
2439
3131
4440
6230
7800
2040
2671
3805
5541
7034
128
124
117
107
99
130
125
117
106
98
133
129
118
112
104
129
125
118
108
100
131
126
118
107
99
183
176
162
153
143
178
171
162
148
137
180
173
162
147
135
152
147
135
128
119
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35G4000-C-7x-SE
90
BXRC-35G4000-D-7x-SE
90
BXRC-35A4001-B-73-SE
93
BXRC-35A4001-C-73-SE
93
BXRC-35A4001-D-73-SE
93
BXRC-40C4001-B-74-SE
70
BXRC-40C4001-C-74-SE
70
BXRC-40C4001-D-74-SE
70
BXRC-40E4000-B-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
2872
3763
5497
7907
10143
2190
2848
4111
5872
7475
2136
2801
3978
5916
7613
2702
3540
5171
7439
9542
2060
2679
3867
5524
7032
2976
3904
5544
8245
10610
3765
4934
7207
10368
13299
2871
3733
5390
7698
9800
2741
3596
5105
7593
9771
2718
3488
4947
6960
8742
2033
2610
3700
5192
6500
1919
2513
3580
5212
6618
2557
3281
4654
6547
8224
1912
2455
3480
4884
6115
2675
3502
4989
7265
9223
3563
4573
6486
9125
11462
2665
3421
4851
6807
8522
2463
3225
4595
6690
8493
148
143
135
123
114
150
144
135
123
113
143
138
127
120
112
139
134
127
116
108
141
136
127
115
106
200
193
177
168
156
194
187
177
162
150
197
189
177
161
148
184
178
163
154
144
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40E4000-C-7x-SE
80
BXRC-40E4000-D-7x-SE
80
BXRC-40G4000-B-7x-SE
90
BXRC-40G4000-C-7x-SE
90
BXRC-40G4000-D-7x-SE
90
BXRC-40H4000-B-7x-SE
97
BXRC-40H4000-C-7x-SE
97
BXRC-40H4000-D-7x-SE
97
BXRC-40A4001-B-73-SE
93
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
3468
4544
6637
9548
12247
2644
3438
4963
7089
9025
2354
3088
4385
6522
8392
2978
3903
5700
8200
10519
2271
2953
4263
6089
7751
2018
2647
3758
5590
7193
2553
3345
4886
7029
9016
1947
2531
3654
5219
6644
2287
3000
4260
6335
8152
3282
4211
5973
8403
10555
2454
3151
4467
6269
7848
2115
2770
3946
5746
7295
2819
3617
5130
7218
9066
2108
2706
3837
5384
6741
1813
2374
3383
4925
6253
2416
3100
4397
6187
7771
1807
2320
3289
4615
5778
2055
2691
3834
5582
7087
179
172
163
149
138
182
174
163
148
136
158
152
140
133
123
153
148
140
128
119
156
149
140
127
117
135
131
120
114
106
132
127
120
110
102
134
128
120
109
100
153
148
136
129
120
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A4001-C-73-SE
93
BXRC-40A4001-D-73-SE
93
BXRC-50C4001-B-7x-SE
70
BXRC-50C4001-C-7x-SE
70
BXRC-50C4001-D-7x-SE
70
BXRC-50E4001-B-7x-SE
80
BXRC-50E4001-C-7x-SE
80
BXRC-50E4001-D-7x-SE
80
BXRC-50G4001-B-7x-SE
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
2893
3791
5537
7966
10218
2206
2869
4141
5915
7530
3010
3949
5606
8338
10730
3808
4990
7288
10485
13449
2904
3776
5451
7785
9911
2825
3706
5262
7826
10070
3574
4683
6840
9840
12623
2725
3544
5116
7307
9302
2405
3154
4479
6661
8572
2738
3513
4984
7011
8807
2048
2629
3727
5231
6548
2705
3541
5046
7347
9327
3604
4624
6559
9228
11592
2695
3460
4905
6884
8618
2539
3324
4736
6895
8754
3382
4340
6156
8661
10879
2529
3247
4604
6461
8089
2161
2829
4031
5869
7451
149
144
136
124
115
152
145
136
123
114
202
195
179
169
158
196
189
179
163
152
199
191
179
162
150
189
183
168
159
148
184
178
168
153
142
187
179
168
152
140
161
156
143
135
126
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G4001-C-7x-SE
90
BXRC-50G4001-D-7x-SE
90
BXRC-56G4000-B-74-SE
80
BXRC-56G4000-C-74-SE
80
BXRC-56G400x-D-74-SE
80
BXRC-56H4000-D-74-SE
97
BXRC-57C4001-B-7x-SE
70
BXRC-57C4001-C-7x-SE
70
BXRC-57C4001-D-7x-SE
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
3042
3986
5822
8376
10744
2320
3016
4354
6220
7918
2522
3309
4698
6987
8992
3191
4182
6107
8786
11270
2433
3164
4568
6524
8305
2109
2742
3959
5654
7198
2909
3816
5418
8059
10370
3680
4823
7044
10133
12998
2806
3649
5268
7524
9579
2879
3694
5240
7372
9260
2153
2764
3919
5500
6885
2267
2968
4228
6156
7816
3020
3875
5497
7733
9714
2258
2899
4111
5769
7222
1957
2513
3563
5000
6259
2614
3423
4877
7100
9015
3483
4469
6339
8919
11203
2605
3344
4741
6654
8330
157
151
143
131
121
159
153
143
130
120
169
163
150
142
132
164
159
150
137
127
167
160
150
136
125
145
139
130
118
109
195
188
173
164
152
190
183
173
158
146
193
185
173
157
145
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57E4001-B-7x-SE
80
BXRC-57E4001-C-7x-SE
80
BXRC-57E4001-D-7x-SE
80
BXRC-65C4001-B-7x-SE
70
BXRC-65C4001-C-7x-SE
70
BXRC-65C4001-D-7x-SE
70
BXRC-65E4001-B-7x-SE
80
BXRC-65E4001-C-7x-SE
80
BXRC-65E4001-D-7x-SE
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
450
600
900
1350
1800
585
780
1170
1755
2340
525
700
1050
1575
2100
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
33.1
33.8
34.8
36.5
37.8
33.2
33.8
34.8
36.5
37.9
27.7
28.2
29.0
30.4
31.5
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
14.9
20.3
31.3
49.2
68.1
19.4
26.4
40.7
64.1
88.8
14.6
19.8
30.5
47.9
66.2
2791
3662
5199
7733
9951
3531
4628
6759
9723
12472
2693
3501
5055
7220
9191
2960
3882
5512
8198
10550
3744
4906
7166
10309
13224
2855
3712
5359
7655
9745
2842
3728
5293
7872
10130
3595
4711
6881
9899
12698
2741
3565
5146
7350
9357
2508
3284
4679
6813
8650
3342
4288
6083
8558
10750
2499
3209
4549
6384
7992
2659
3482
4961
7224
9171
3543
4547
6449
9074
11397
2650
3402
4823
6769
8474
2554
3344
4764
6936
8806
3402
4366
6193
8713
10944
2544
3267
4631
6500
8137
187
181
166
157
146
182
176
166
152
141
185
177
166
151
139
198
192
176
167
155
193
186
176
161
149
196
188
176
160
147
191
184
169
160
149
185
179
169
154
143
188
180
169
153
141
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
19
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx400x-B-7x-SE
BXRC-xxx400x-C-7x-SE
BXRC-xxx400x-D-7x-SE
Drive
Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.15
31.0
38.4
-14.9
0.19
33.8
41.6
37.4
-14.9
0.11
31.0
38.4
37.8
40.6
-14.9
0.13
33.8
41.6
26.8
29.0
31.2
-12.2
0.16
25.8
32.0
29.2
31.5
33.9
-12.2
0.19
28.2
34.7
Minimum
Typical
Maximum
900
32.2
34.8
37.4
-14.9
1800
35.0
37.8
40.6
1170
32.2
34.8
2340
35.0
1050
2100
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal
interface material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design
and selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
20
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx400x-B-7x-SE
BXRC-xxx400x-C-7x-SE
BXRC-xxx400x-D-7x-SE
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
900
RG1
RG1
RG1
RG1
1350
RG1
RG1
RG1
RG2
1800
RG1
RG1
RG2
RG2
1170
RG1
RG1
RG1
RG1
1755
RG1
RG1
RG2
RG2
2340
RG1
RG1
RG2
RG2
1050
RG1
RG1
RG1
RG1
1575
RG1
RG1
RG1
RG2
2100
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC
62471 for the assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
21
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
BXRC-xxx400x-B-7x-SE
BXRC-xxx400x-C-7x-SE
BXRC-xxx400x-D-7x-SE
Maximum Drive Current3
1800mA
2340mA
2100mA
Maximum Peak Pulsed Drive Current4
2570mA
3340mA
3000mA
Maximum Reverse Voltage5
-60V
-60V
-50V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
22
Performance Curves
Figure 2: Vero SE 18C Drive Current vs. Voltage
2000
2700
1800
2400
1600
2100
1400
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero SE 18B Drive Current vs. Voltage
1200
1000
800
600
1800
1500
1200
900
600
400
300
200
0
0
32
33
34
35
36
37
38
39
32
33
34
200%
2000
180%
1750
160%
1500
140%
Relative Luminous Flux
Forward Current (mA)
2250
1250
37
38
39
1000
750
500
120%
100%
80%
60%
40%
250
20%
26
27
28
29
30
31
0%
32
0
200
400
600
Forward Voltage (V)
800
1000
1200
1400
1600
1800
2000
Forward Current (mA)
Figure 5: Vero SE 18C Typical Relative Flux vs. Current
Figure 6: Vero SE 18D Typical Relative Flux vs.
Current
y = -7E-08x + 0.001x + 0.027
2
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
36
Figure 4: Vero SE 18B Typical Relative Flux vs. Current
Figure 3: Vero SE 18D Drive Current vs. Voltage
0
35
Forward Voltage (V)
Forward Voltage (V)
120%
100%
80%
60%
40%
120%
100%
80%
60%
40%
20%
20%
0%
100
400
700
1000
1300
1600
Forward Current (mA)
1900
2200
2500
0%
200
400
600
800
1000
1200
1400
1600
1800
2000
2200
2400
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
23
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
Figure 7: Typical DC Flux vs. Case Temperature
0
103%
Neutral White
50
75
100
125
0.000
Cool White
25°C Pulsed
97%
-0.003
ccy Shift
Relative Luminous Flux
100%
25
0.003
Warm White
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
-0.015
82%
0
25
50
75
100
125
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Case Temperature (°C)
Figure 9: Typical DC ccx Shift vs. Case Temperature
0
25
50
75
100
125
0.000
-0.002
ccx Shift
-0.004
-0.006
-0.008
Warm White
-0.010
-0.012
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
24
Performance Curves
Figure 10: 1750K Color Shift vs. Case Temperature1
Figure 11: 2000K, 65 CRI Color Shift vs. Case Temperature1
0.3705
0.37
0.4101
Pulsed Center Point
Tc = 25°C
15°C
0.41
0.4099
25°C
0.4098
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
0.3695
0.369
ccy
ccy
45°C
45°C
0.4096
0.4095
65°C
0.4094
70°C
0.4093
85°C
0.3685
85°C
0.4092
105°C
0.368
0.5196
105°C
0.4091
0.5198
0.52
0.5202
0.5204
0.409
0.525
0.5206
0.526
0.527
0.528
Figure 12: 2500K Color Shift vs. Case Temperature1
0.4135
Pulsed
Center Point
Tc = 25°C
0.411
70°C
0.399
65°C
85°C
0.397
105°C
0.396
0.47
45°C
0.398
85°C
0.4105
0.468
Pulsed Center
Point Tc=25°C
25°C
0.4
0.4125
0.4115
0.472
0.474
0.476
0.395
0.444
0.478
105°C
0.4445
0.445
0.4455
0.446
0.4465
0.447
ccx
ccx
Figure 14: 2700K, 97 CRI Color Shift vs. Case Temperature1
Figure 15: 3000K, 97 CRI Color Shift vs. Case Temperature1
0.4110
0.4050
15°C
Pulsed Center
Point
Tc = 25°C
0.4100
25°C
0.4080
Pulsed Center
Point
Tc = 25°C
15°C
0.4030
25°C
0.4090
45°C
0.4010
45°C
ccy
ccy
0.532
0.401
45°C
0.412
15°C
0.402
ccy
ccy
0.413
0.531
0.403
15°C
25°C
0.53
Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature1,3,4
0.4145
0.414
0.529
ccx
ccx
0.4070
65°C
70°C
0.3990
0.4060
85°C
85°C
0.4050
0.3970
105°C
0.4040
105°C
0.4030
0.457
0.4572
0.4574
0.4576
0.4578
0.458
ccx
Notes for Figures 10-15:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRC-30G400C-x-73-SE
4. Color shift shown for product hot targeted at Tc=85°C
0.3950
0.4323
0.4328
0.4333
0.4338
0.4343
0.4348
0.4353
ccx
25
Performance Curves
Figure 16: 5600K Color Shift vs. Case Temperature1
Figure 17: 3000K Class A Color Shift vs. Case Temperature1
0.344
0.369
0.342
25°C
0.338
0.336
0.367
0.366
0.332
70°C
0.33
45°C
0.364
70°C
85°C
0.362
105°C
0.324
0.361
0.322
0.32
0.322
0.324
0.326
0.328
Figure 18: 3500K Class A Color Shift vs. Case Temperature1
105°C
0.36
0.416
0.33
ccx
0.4165
0.417
ccx
0.4175
0.418
0.4185
Figure 19: 4000K Class A Color Shift vs. Case Temperature1
0.3760
0.37
15°C
0.368
15°C
0.3740
Pulsed
Center Point
Tc=25°C
25°C
0.366
25°C
0.3720
45°C
Pulsed
Center Point
Tc=25°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.365
0.363
85°C
0.328
0.326
25°C
45°C
0.334
15°C
0.368
ccy
ccy
Pulsed Center
Point
Tc = 25°C
15°C
0.34
0.364
0.3680
70°C
0.362
0.3660
85°C
0.36
85°C
0.3640
105°C
0.358
0.392
70°C
105°C
0.393
0.394
0.395
0.396
0.397
ccx
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
Notes for Figures 16-19:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
26
Typical Radiation Pattern
Figure 20: Typical Spatial Radiation Pattern
Notes for Figure 20:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 21: Typical Polar Radiation Pattern
27
Typical Color Spectrum
Figure 22: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 22:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 23: Typical Color Spectrum for Vero SE 18 with Décor Series
1
17E
20B
0.9
25E
27H
30G (Décor Series Showcase)
0.8
30H
Relative Spectral Power Distribution
56G
56H
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 23:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
28
Mechanical Dimensions
Figure 24: Drawing for Vero SE 18 LED Array
Notes for Figure 24:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M3 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
29
Color Binning Information
Figure 25: Warm and Neutral White Test Bins in xy Color Space
0.44
3 SDCM
2500K
4SDCM
4 SDCM
2 SDCM
2000K
3SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
1750K
4SDCM
0.38
0.36
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2000K
2500K
2700K
ANSI Bin
(for reference only)
-
-
-
(2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM)
-
-
-
(2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
72 (2 SDCM)
-
-
-
(2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)
Center Point (x,y)
(0.5167, 0.336)
(0.5280, 0.4100) (0.4765, 0.4137)
(0.4578, 0.4101)
3000K1
3500K1
4000K1
(0.4338, 0.403)
(0.4073, 0.3917)
(0.4465, 0.4024)2
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
Figure 26: Graph of Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K1
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
30
Packaging and Labeling
Figure 27: Drawing for Vero SE 18 Packaging Tray
Notes for Figure 27:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
31
Packaging and Labeling
Figure 28: Vero SE Series Packaging and Labeling
Notes for Figure 28:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 29: Vero SE Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E4000C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin
definitions.
32
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales
representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN121 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
33
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Vero SE 18 Array Series Product Data Sheet DS122 Rev. K (11/2018)