Bridgelux Gen 7 Vero 13 Array
®
®
Product Data Sheet DS91
1
Vero® Series
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing
unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color
points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is also designed as a replacement for halogen lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher efficacy.
Features
• Efficacy of 160 lm/W typical
• Lumen output performance ranges from
460 to 7,300 lumens
• Broad range of CCT options from 2700K to 6500K
• CRI options include; minimum 70, 80, and 90
• 2 and 3 SDCM color control for 2700K-4000K CCT
• Reliable operation at up to 2X nominal drive current
• Radial die pattern and improved lumen density
• Thermally isolated solder pads
• Onboard connector port
• Top side part number markings
• Vf bin code backside marking
Benefits
• Broad application coverage for interior and
exterior lighting
• Flexibility for application driven lighting design
requirements
• High quality true color reproduction
• Uniform consistent white light
• Flexibility in design optimization
• Enhanced ease of use and assembly
• Solderless connectivity enables plug & play
installation and field upgradability
• Improved inventory management and
quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
19
Eye Safety
20
Absolute Maximum Ratings
21
Performance Curves
22
Typical Radiation Pattern
25
Typical Color Spectrum
26
Mechanical Dimensions
27
Color Binning Information
28
Packaging and Labeling
29
Design Resources
31
Precautions
31
Disclaimers
31
About Bridgelux
32
1
Product Feature Map
Vero 13 is the second smallest form factor in the Vero
family of the next generation solid state light sources. In
addition to delivering the performance and light quality
required for many lighting applications, Vero incorporates
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
2D Bar code provides full manufacturing traceability
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
Optics location/mounting features
Correlates to the true case temperature
on the back surface of the LED array
Mounting holes
Radial die configuration improves lumen
density and beam control
Zhaga Book 3 compatible
mounting locations
Top side part number marking improves
inventory management and outgoing
quality control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6 7 8 9 10 11
– 12
– 13 14
BXRC – 30 E 200 0 – C – 7 3
CCT Bin Options
Product Family
Nominal CCT
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
57 = 5,700K
65 = 6,500K
Gen. 7
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Flux Indicator
200x = 2000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E2000-B-7x
2700
80
450
2403
2163
34.8
15.7
153
BXRC-27E2000-C-7x
2700
80
630
3365
3028
34.8
21.9
153
BXRC-27E2000-D-7x
2700
80
500
2440
2196
31.8
15.9
153
BXRC-27G20H0-B-7x
2700
90
450
2083
1875
34.8
15.7
133
BXRC-27G20H0-C-7x
2700
90
630
2916
2624
34.8
21.9
133
BXRC-27G20H0-D-7x
2700
90
500
2115
1903
31.8
15.9
133
BXRC-27G2000-B-7x
2700
90
450
2000
1800
34.8
15.7
128
BXRC-27G2000-C-7x
2700
90
630
2800
2520
34.8
21.9
128
BXRC-27G2000-D-7x
2700
90
500
2031
1828
31.8
15.9
128
BXRC-27H2000-B-7x
2700
97
450
1742
1568
34.8
15.7
111
BXRC-27H2000-C-7x
2700
97
630
2439
2195
34.8
21.9
111
BXRC-27H2000-D-7x
2700
97
500
1769
1592
31.8
15.9
111
BXRC-30C2001-B-74
3000
70
450
2756
2481
34.8
15.7
176
176
BXRC-30C2001-C-74
3000
70
630
3859
3473
34.8
21.9
BXRC-30C2001-D-74
3000
70
500
2798
2519
31.8
15.9
176
BXRC-30E2000-B-7x
3000
80
450
2500
2250
34.8
15.7
160
BXRC-30E2000-C-7x
3000
80
630
3500
3150
34.8
21.9
160
BXRC-30E2000-D-7x
3000
80
500
2538
2285
31.8
15.9
160
BXRC-30G20H0-B-7x
3000
90
450
2177
1959
34.8
15.7
139
BXRC-30G20H0-C-7x
3000
90
630
3047
2743
34.8
21.9
139
BXRC-30G20H0-D-7x
3000
90
500
2210
1989
31.8
15.9
139
BXRC-30G2000-B-7x
3000
90
450
2081
1873
34.8
15.7
133
BXRC-30G2000-C-7x
3000
90
630
2913
2622
34.8
21.9
133
BXRC-30G2000-D-7x
3000
90
500
2113
1901
31.8
15.9
133
BXRC-30G200C-B-73
3000
90
450
1947
1752
35.0
15.8
124
BXRC-30G200C-D-73
3000
90
500
1965
1769
31.8
15.9
124
BXRC-30H2000-B-7x
3000
97
450
1855
1669
34.8
15.7
118
BXRC-30H2000-C-7x
3000
97
630
2597
2337
34.8
21.9
118
BXRC-30H2000-D-7x
3000
97
500
1883
1695
31.8
15.9
118
BXRC-30A2001-B-738,9
3000
93
450
1879
1691
34.8
15.7
120
BXRC-30A2001-C-738,9
3000
93
630
2631
2368
34.8
21.9
120
BXRC-30A2001-D-738,9
3000
93
500
1908
1717
31.8
15.9
120
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E2000-B-7x
3500
80
450
2581
2323
34.8
15.7
165
BXRC-35E2000-C-7x
3500
80
630
3613
3252
34.8
21.9
165
BXRC-35E2000-D-7x
3500
80
500
2620
2358
31.8
15.9
165
BXRC-35G2000-B-7x
3500
90
450
2145
1931
34.8
15.7
137
BXRC-35G2000-C-7x
3500
90
630
3003
2703
34.8
21.9
137
BXRC-35G2000-D-7x
3500
90
500
2178
1960
31.8
15.9
137
BXRC-35A2001-B-738,9
3500
93
450
2020
1818
34.8
15.7
129
BXRC-35A2001-C-738,9
3500
93
630
2828
2545
34.8
21.9
129
BXRC-35A2001-D-73
3500
93
500
2051
1846
31.8
15.9
129
BXRC-40C2001-B-74
4000
70
450
2803
2523
34.8
15.7
179
179
8,9
BXRC-40C2001-C-74
4000
70
630
3924
3532
34.8
21.9
BXRC-40C2001-D-74
4000
70
500
2846
2561
31.8
15.9
179
BXRC-40E2000-B-7x
4000
80
450
2597
2337
34.8
15.7
166
BXRC-40E2000-C-7x
4000
80
630
3636
3272
34.8
21.9
166
BXRC-40E2000-D-7x
4000
80
500
2637
2373
31.8
15.9
166
BXRC-40G2000-B-7x
4000
90
450
2226
2003
34.8
15.7
142
BXRC-40G2000-C-7x
4000
90
630
3116
2805
34.8
21.9
142
BXRC-40G2000-D-7x
4000
90
500
2260
2034
31.8
15.9
142
BXRC-40H2000-B-73
4000
97
450
1911
1719
34.8
15.7
122
BXRC-40H2000-C-73
4000
97
630
2675
2407
34.8
21.9
122
BXRC-40H2000-D-73
4000
97
500
1940
1746
31.8
15.9
122
BXRC-40A2001-B-738,9
4000
93
450
2161
1945
34.8
15.7
138
BXRC-40A2001-C-738,9
4000
93
630
3026
2723
34.8
21.9
138
BXRC-40A2001-D-738,9
4000
93
500
2194
1975
31.8
15.9
138
BXRC-50C2001-B-7x
5000
70
450
2855
2569
34.8
15.7
182
BXRC-50C2001-C-7x
5000
70
630
3997
3597
34.8
21.9
182
BXRC-50C2001-D-7x
5000
70
500
2899
2609
31.8
15.9
182
BXRC-50E2001-B-7x
5000
80
450
2678
2410
34.8
15.7
171
BXRC-50E2001-C-7x
5000
80
630
3749
3374
34.8
21.9
171
BXRC-50E2001-D-7x
5000
80
500
2719
2447
31.8
15.9
171
BXRC-50G2001-B-7x
5000
90
450
2274
2047
34.8
15.7
145
BXRC-50G2001-C-7x
5000
90
630
3184
2866
34.8
21.9
145
BXRC-50G2001-D-7x
5000
90
500
2309
2078
31.8
15.9
145
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C2001-B-7x
5700
70
450
2758
2482
34.8
15.7
176
176
BXRC-57C2001-C-7x
5700
70
630
3861
3475
34.8
21.9
BXRC-57C2001-D-7x
5700
70
500
2800
2520
31.8
15.9
176
BXRC-57E2001-B-7x
5700
80
450
2647
2382
34.8
15.7
169
BXRC-57E2001-C-7x
5700
80
630
3705
3335
34.8
21.9
169
BXRC-57E2001-D-7x
5700
80
500
2687
2418
31.8
15.9
169
BXRC-65C2001-B-7x
6500
70
450
2807
2526
34.8
15.7
179
BXRC-65C2001-C-7x
6500
70
630
3929
3536
34.8
21.9
179
BXRC-65C2001-D-7x
6500
70
500
2850
2565
31.8
15.9
179
BXRC-65E2001-B-7x
6500
80
450
2694
2424
34.8
15.7
172
BXRC-65E2001-C-7x
6500
80
630
3771
3394
34.8
21.9
172
BXRC-65E2001-D-7x
6500
80
500
2735
2461
31.8
15.9
172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
113
BXRC-30A2001-B-73
3000
80
93
450
1748
1573
34.4
15.5
BXRC-30A2001-C-73
3000
80
93
630
2447
2202
34.4
21.6
113
BXRC-30A2001-D-73
3000
80
93
500
1774
1597
31.2
15.6
114
121
BXRC-35A2001-B-73
3500
80
93
450
1879
1691
34.4
15.5
BXRC-35A2001-C-73
3500
80
93
630
2630
2367
34.4
21.6
121
BXRC-35A2001-D-73
3500
80
93
500
1908
1717
31.2
15.6
122
BXRC-40A2001-B-73
4000
80
93
450
2010
1809
34.4
15.5
130
BXRC-40A2001-C-73
4000
80
93
630
2814
2532
34.4
21.6
130
BXRC-40A2001-D-73
4000
80
93
500
2041
1837
31.2
15.6
131
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-27E2000-B-7x
2700
80
450
2163
1947
33.9
15.3
142
BXRC-27E2000-C-7x
2700
80
630
3028
2725
33.9
21.4
142
BXRC-27E2000-D-7x
2700
80
500
2196
1977
30.9
15.5
142
BXRC-27G20H0-B-7x
2700
90
450
1875
1687
33.9
15.3
123
BXRC-27G20H0-C-7x
2700
90
630
2624
2362
33.9
21.4
123
BXRC-27G20H0-D-7x
2700
90
500
1903
1713
30.9
15.5
123
BXRC-27G2000-B-7x
2700
90
450
1800
1620
33.9
15.3
118
BXRC-27G2000-C-7x
2700
90
630
2520
2268
33.9
21.4
118
BXRC-27G2000-D-7x
2700
90
500
1828
1645
30.9
15.5
118
BXRC-27H2000-B-7x
2700
97
450
1568
1411
33.9
15.3
103
BXRC-27H2000-C-7x
2700
97
630
2195
1975
33.9
21.4
103
BXRC-27H2000-D-7x
2700
97
500
1592
1433
30.9
15.5
103
BXRC-30C2001-B-74
3000
70
450
2481
2232
33.9
15.3
163
BXRC-30C2001-C-74
3000
70
630
3473
3125
33.9
21.4
163
BXRC-30C2001-D-74
3000
70
500
2519
2267
30.9
15.5
163
BXRC-30E2000-B-7x
3000
80
450
2250
2025
33.9
15.3
147
BXRC-30E2000-C-7x
3000
80
630
3150
2835
33.9
21.4
147
BXRC-30E2000-D-7x
3000
80
500
2285
2056
30.9
15.5
148
BXRC-30G20H0-B-7x
3000
90
450
1959
1763
33.9
15.3
128
BXRC-30G20H0-C-7x
3000
90
630
2743
2468
33.9
21.4
128
BXRC-30G20H0-D-7x
3000
90
500
1989
1790
30.9
15.5
129
BXRC-30G2000-B-7x
3000
90
450
1873
1685
33.9
15.3
123
BXRC-30G2000-C-7x
3000
90
630
2622
2360
33.9
21.4
123
BXRC-30G2000-D-7x
3000
90
500
1901
1711
30.9
15.5
123
BXRC-30G200C-B-73
3000
90
450
1752
1577
34.1
15.3
114
BXRC-30G200C-D-73
3000
90
500
1769
1592
30.9
15.5
114
BXRC-30H2000-B-7x
3000
97
450
1669
1502
33.9
15.3
109
BXRC-30H2000-C-7x
3000
97
630
2337
2103
33.9
21.4
109
BXRC-30H2000-D-7x
3000
97
500
1695
1526
30.9
15.5
110
BXRC-30A2001-B-7x
7,8
3000
93
450
1691
1522
33.9
15.3
111
BXRC-30A2001-C-7x7,8
3000
93
630
2368
2131
33.9
21.4
111
BXRC-30A2001-D-7x7,8
3000
93
500
1717
1545
30.9
15.5
111
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E2000-B-7x
3500
80
450
2323
2090
33.9
15.3
152
BXRC-35E2000-C-7x
3500
80
630
3252
2927
33.9
21.4
152
BXRC-35E2000-D-7x
3500
80
500
2358
2122
30.9
15.5
152
BXRC-35G2000-B-7x
3500
90
450
1931
1738
33.9
15.3
127
BXRC-35G2000-C-7x
3500
90
630
2703
2433
33.9
21.4
127
BXRC-35G2000-D-7x
3500
90
500
1960
1764
30.9
15.5
127
BXRC-35A2001-B-737,8
3500
93
450
1818
1636
33.9
15.3
119
BXRC-35A2001-C-737,8
3500
93
630
2545
2291
33.9
21.4
119
BXRC-35A2001-D-737,8
3500
93
500
1846
1661
30.9
15.5
119
BXRC-40C2001-B-74
4000
70
450
2523
2271
33.9
15.3
165
BXRC-40C2001-C-74
4000
70
630
3532
3179
33.9
21.4
165
BXRC-40C2001-D-74
4000
70
500
2561
2305
30.9
15.5
166
BXRC-40E2000-B-7x
4000
80
450
2337
2103
33.9
15.3
153
BXRC-40E2000-C-7x
4000
80
630
3272
2945
33.9
21.4
153
BXRC-40E2000-D-7x
4000
80
500
2373
2136
30.9
15.5
153
BXRC-40G2000-B-7x
4000
90
450
2003
1803
33.9
15.3
131
BXRC-40G2000-C-7x
4000
90
630
2805
2524
33.9
21.4
131
BXRC-40G2000-D-7x
4000
90
500
2034
1831
30.9
15.5
132
BXRC-40H2000-B-73
4000
97
450
1719
1548
33.9
15.3
113
BXRC-40H2000-C-73
4000
97
630
2407
2167
33.9
21.4
113
BXRC-40H2000-D-73
4000
97
500
1746
1571
30.9
15.5
113
BXRC-40A2001-B-737,8
4000
93
450
1945
1750
33.9
15.3
127
BXRC-40A2001-C-737,8
4000
93
630
2723
2451
33.9
21.4
127
BXRC-40A2001-D-737,8
4000
93
500
1975
1777
30.9
15.5
128
BXRC-50C2001-B-7x
5000
70
450
2569
2313
33.9
15.3
168
BXRC-50C2001-C-7x
5000
70
630
3597
3238
33.9
21.4
168
BXRC-50C2001-D-7x
5000
70
500
2609
2348
30.9
15.5
169
BXRC-50E2001-B-7x
5000
80
450
2410
2169
33.9
15.3
158
BXRC-50E2001-C-7x
5000
80
630
3374
3036
33.9
21.4
158
BXRC-50E2001-D-7x
5000
80
500
2447
2202
30.9
15.5
158
BXRC-50G2001-B-7x
5000
90
450
2047
1842
33.9
15.3
134
BXRC-50G2001-C-7x
5000
90
630
2866
2579
33.9
21.4
134
BXRC-50G2001-D-7x
5000
90
500
2078
1870
30.9
15.5
134
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C2001-B-7x
5700
70
450
2482
2234
33.9
15.3
163
BXRC-57C2001-C-7x
5700
70
630
3475
3128
33.9
21.4
163
BXRC-57C2001-D-7x
5700
70
500
2520
2268
30.9
15.5
163
BXRC-57E2001-B-7x
5700
80
450
2382
2144
33.9
15.3
156
BXRC-57E2001-C-7x
5700
80
630
3335
3001
33.9
21.4
156
BXRC-57E2001-D-7x
5700
80
500
2418
2177
30.9
15.5
156
BXRC-65C2001-B-7x
6500
70
450
2526
2273
33.9
15.3
166
BXRC-65C2001-C-7x
6500
70
630
3536
3183
33.9
21.4
166
BXRC-65C2001-D-7x
6500
70
500
2565
2308
30.9
15.5
166
BXRC-65E2001-B-7x
6500
80
450
2424
2182
33.9
15.3
159
BXRC-65E2001-C-7x
6500
80
630
3394
3054
33.9
21.4
159
BXRC-65E2001-D-7x
6500
80
500
2461
2215
30.9
15.5
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-27E2000-B-7x
80
BXRC-27E2000-C-7x
80
BXRC-27E2000-D-7x
80
BXRC-27G20H0-B-7x
90
BXRC-27G20H0-C-7x
90
BXRC-27G20H0-D-7x
90
BXRC-27G2000-B-7x
90
BXRC-27G2000-C-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
655
1267
2403
3473
4430
909
1760
3365
4829
6164
646
1252
2440
3448
4409
567
1098
2083
3010
3839
788
1525
2916
4185
5342
560
1085
2115
2988
3821
545
1054
2000
2890
3687
757
1465
2800
4019
5130
600
1149
2163
3042
3805
859
1657
3028
4515
5743
617
1193
2196
3267
4167
520
996
1875
2636
3298
745
1436
2624
3913
4977
535
1034
1903
2831
3611
499
956
1800
2531
3167
715
1379
2520
3757
4779
175
166
153
144
136
174
164
153
143
135
175
165
153
139
128
152
143
133
125
118
151
142
133
124
117
152
143
133
120
111
146
138
128
120
113
145
137
128
119
113
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27G2000-D-7x
90
BXRC-27H2000-B-7x
97
BXRC-27H2000-C-7x
97
BXRC-27H2000-D-7x
97
BXRC-30C2001-B-74
70
BXRC-30C2001-C-74
70
BXRC-30C2001-D-74
70
BXRC-30E2000-B-7x
80
BXRC-30E2000-C-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
538
1042
2031
2870
3669
474
918
1742
2517
3211
659
1276
2439
3500
4468
468
908
1769
2499
3196
751
1453
2756
3983
5081
1043
2018
3859
5538
7069
741
1436
2798
3955
5056
681
1318
2500
3613
4609
946
1831
3500
5024
6412
513
993
1828
2719
3468
435
833
1568
2205
2758
623
1201
2195
3272
4163
447
864
1592
2368
3020
688
1318
2481
3488
4364
986
1901
3473
5177
6586
707
1368
2519
3746
4778
624
1195
2250
3164
3959
894
1724
3150
4697
5974
146
137
128
115
107
127
120
111
105
99
126
119
111
104
98
127
120
111
100
93
201
190
176
166
156
199
188
176
164
155
201
189
176
159
147
182
172
160
150
142
181
171
160
149
141
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30E2000-D-7x
80
BXRC-30G20H0-B-7x
90
BXRC-30G20H0-C-7x
90
BXRC-30G20H0-D-7x
90
BXRC-30G2000-B-7x
90
BXRC-30G2000-C-7x
90
BXRC-30G2000-D-7x
90
BXRC-30G200C-B-73
90
BXRC-30G200C-D-73
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
125
250
500
750
1000
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
3.7
7.6
15.9
24.9
34.4
672
1303
2538
3587
4587
593
1147
2177
3146
4013
823
1594
3047
4374
5583
585
1134
2210
3123
3993
567
1097
2081
3007
3836
787
1524
2913
4181
5336
559
1084
2113
2985
3817
530
1026
1947
2813
3589
520
1008
1965
2777
3551
642
1241
2285
3398
4334
543
1041
1959
2755
3447
778
1501
2743
4089
5202
559
1080
1989
2959
3774
519
995
1873
2633
3295
744
1435
2622
3909
4972
534
1033
1901
2828
3607
486
931
1752
2464
3082
497
961
1769
2631
3356
182
172
160
144
133
159
150
139
131
123
157
149
139
130
123
158
150
139
125
116
152
143
133
125
118
150
142
133
124
117
151
143
133
120
111
142
134
124
117
110
141
133
124
112
103
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30H2000-B-7x
97
BXRC-30H2000-C-7x
97
BXRC-30H2000-D-7x
97
BXRC-30A2001-B-73
93
BXRC-30A2001-C-73
93
BXRC-30A2001-D-73
93
BXRC-35E2000-B-7x
80
BXRC-35E2000-C-7x
80
BXRC-35E2000-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
505
978
1855
2681
3419
702
1358
2597
3727
4757
499
966
1883
2661
3403
512
991
1879
2716
3464
711
1376
2631
3776
4819
505
979
1908
2696
3448
703
1360
2581
3730
4757
976
1890
3613
5186
6619
694
1345
2620
3703
4735
463
887
1669
2348
2937
663
1279
2337
3485
4433
476
920
1695
2521
3216
469
898
1691
2378
2976
672
1296
2368
3530
4491
482
933
1717
2554
3258
644
1234
2323
3266
4086
923
1780
3252
4848
6167
662
1281
2358
3508
4474
135
128
118
111
105
134
127
118
111
104
135
127
118
107
99
137
129
120
113
106
136
128
120
112
106
137
129
120
108
100
188
178
165
155
146
187
176
165
154
145
188
177
165
149
138
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35G2000-B-7x
90
BXRC-35G2000-C-7x
90
BXRC-35G2000-D-7x
90
BXRC-35A2001-B-73
93
BXRC-35A2001-C-73
93
BXRC-35A2001-D-73
93
BXRC-40C2001-B-74
70
BXRC-40C2001-C-74
70
BXRC-40C2001-D-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
584
1131
2145
3100
3955
811
1571
3003
4311
5502
577
1118
2178
3078
3936
550
1065
2020
2919
3724
764
1479
2828
4059
5181
543
1053
2051
2899
3706
763
1478
2803
4051
5167
1060
2053
3924
5633
7189
753
1460
2846
4022
5143
535
1026
1931
2715
3397
767
1479
2703
4030
5126
551
1065
1960
2916
3719
504
966
1818
2557
3199
722
1393
2545
3795
4827
519
1002
1846
2746
3502
700
1340
2523
3548
4438
1002
1933
3532
5266
6698
720
1391
2561
3810
4860
156
148
137
129
122
155
147
137
128
121
156
147
137
124
114
147
139
129
121
114
146
138
129
121
114
147
139
129
116
108
204
193
179
168
159
203
192
179
167
158
204
193
179
162
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40E2000-B-7x
80
BXRC-40E2000-C-7x
80
BXRC-40E2000-D-7x
80
BXRC-40G2000-B-7x
90
BXRC-40G2000-C-7x
90
BXRC-40G2000-D-7x
90
BXRC-40H2000-B-7x
97
BXRC-40H2000-C-7x
97
BXRC-40H2000-D-7x
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
707
1369
2597
3753
4787
982
1902
3636
5218
6660
698
1353
2637
3726
4764
606
1173
2226
3217
4103
842
1630
3116
4473
5709
598
1160
2260
3194
4084
520
1007
1911
2761
3522
723
1399
2675
3839
4900
513
995
1940
2741
3505
648
1242
2337
3287
4112
929
1791
3272
4878
6206
667
1289
2373
3530
4502
556
1064
2003
2817
3525
796
1535
2805
4181
5319
571
1105
2034
3026
3859
477
913
1719
2418
3025
683
1317
2407
3589
4565
490
948
1746
2597
3312
189
179
166
156
147
188
178
166
155
146
189
178
166
150
138
162
153
142
134
126
161
152
142
133
125
162
153
142
128
119
139
132
122
115
108
138
131
122
114
108
139
131
122
110
102
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A2001-B-73
93
BXRC-40A2001-C-73
93
BXRC-40A2001-D-73
93
BXRC-50C2001-B-7x
70
BXRC-50C2001-C-7x
70
BXRC-50C2001-D-7x
70
BXRC-50E2001-B-7x
80
BXRC-50E2001-C-7x
80
BXRC-50E2001-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
589
1139
2161
3123
3984
817
1583
3026
4343
5542
581
1126
2194
3101
3965
778
1505
2855
4126
5263
1080
2091
3997
5737
7322
767
1487
2899
4096
5238
729
1411
2678
3869
4936
1013
1961
3749
5380
6867
720
1395
2719
3842
4912
539
1033
1945
2735
3422
773
1490
2723
4060
5164
555
1072
1975
2937
3747
713
1365
2569
3613
4521
1021
1969
3597
5363
6822
733
1417
2609
3881
4950
668
1280
2410
3389
4240
958
1846
3374
5030
6398
687
1329
2447
3640
4642
158
149
138
130
122
156
148
138
129
122
157
148
138
125
115
208
197
182
172
162
206
195
182
170
161
208
196
182
165
152
195
184
171
161
152
194
183
171
160
151
195
184
171
154
143
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G2001-B-7x
90
BXRC-50G2001-C-7x
90
BXRC-50G2001-D-7x
90
BXRC-57C2001-B-7x
70
BXRC-57C2001-C-7x
70
BXRC-57C2001-D-7x
70
BXRC-57E2001-B-7x
80
BXRC-57E2001-C-7x
80
BXRC-57E2001-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
619
1199
2274
3287
4192
860
1665
3184
4570
5833
611
1185
2309
3263
4172
751
1454
2758
3986
5084
1043
2020
3861
5542
7074
741
1437
2800
3957
5060
721
1395
2647
3825
4879
1001
1938
3705
5318
6787
711
1379
2687
3797
4855
568
1087
2047
2878
3601
813
1568
2866
4272
5435
584
1129
2078
3091
3943
688
1319
2482
3491
4367
986
1902
3475
5181
6591
708
1369
2520
3749
4782
661
1265
2382
3349
4191
946
1825
3335
4972
6324
679
1313
2418
3597
4588
166
157
145
137
129
164
155
145
136
128
165
156
145
131
121
201
190
176
166
156
199
189
176
165
155
201
189
176
159
147
193
182
169
159
150
191
181
169
158
149
193
182
169
153
141
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-65C2001-B-7x
70
BXRC-65C2001-C-7x
70
BXRC-65C2001-D-7x
70
BXRC-65E2001-B-7x
80
BXRC-65E2001-C-7x
80
BXRC-65E2001-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
113
225
450
675
900
158
315
630
945
1260
125
250
500
750
1000
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
33.2
34.0
34.8
35.6
36.1
33.2
34.0
34.8
35.6
36.1
29.6
30.3
31.8
33.2
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
3.7
7.7
15.7
24.1
32.5
5.2
10.7
21.9
33.7
45.5
3.7
7.6
15.9
24.9
34.4
764
1479
2807
4056
5174
1062
2055
3929
5640
7198
754
1462
2850
4027
5149
734
1420
2694
3893
4965
1019
1972
3771
5412
6908
724
1403
2735
3865
4942
700
1342
2526
3552
4444
1004
1935
3536
5272
6707
720
1393
2565
3815
4866
672
1288
2424
3409
4265
963
1857
3394
5060
6437
691
1337
2461
3661
4670
205
193
179
169
159
203
192
179
167
158
204
193
179
162
150
196
186
172
162
153
195
184
172
161
152
196
185
172
155
144
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx200x-B-7x
BXRC-xxx200x-C-7x
BXRC-xxx200x-D-7x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.28
31.0
38.3
-14.3
0.35
32.2
39.7
37.4
-14.3
0.20
31.0
38.3
36.1
38.8
-14.3
0.24
32.2
39.7
29.4
31.8
34.2
-13.3
0.34
28.4
35.0
31.8
34.4
37.0
-13.3
0.41
30.8
37.9
Minimum
Typical
Maximum
450
32.2
34.8
37.4
-14.3
900
33.4
36.1
38.8
630
32.2
34.8
1260
33.4
500
1000
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
19
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx200x-B-7x
BXRC-xxx200x-C-7x
BXRC-xxx200x-D-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
450
RG1
RG1
RG1
RG1
675
RG1
RG1
RG1
RG2
900
RG1
RG1
RG2
RG2
630
RG1
RG1
RG1
RG1
945
RG1
RG1
RG2
RG2
1260
RG1
RG2
RG2
RG2
500
RG1
RG1
RG1
RG1
750
RG1
RG1
RG1
RG2
1000
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
20
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx200x-B-7x
BXRC-xxx200x-C-7x
BXRC-xxx200x-D-7x
Maximum Drive Current3
900mA
1260mA
1000mA
Maximum Peak Pulsed Drive Current4
1290mA
1800mA
1430mA
Maximum Reverse Voltage5
-60V
-60V
-55V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
21
Performance Curves
Figure 1: Vero 13B Drive Current vs. Voltage
Figure 2: Vero 13C Drive Current vs. Voltage
1000
1400
900
1200
700
Forward Current (mA)
Forward Current (mA)
800
600
500
400
300
1000
800
600
400
200
200
100
0
32
33
34
35
36
37
0
38
32
33
34
Forward Voltage (V)
35
36
37
38
Forward Voltage (V)
Figure 3: Vero 13D Drive Current vs. Voltage
Figure 4: Vero 13B Typical Relative Flux vs. Current
200%
1100
180%
1000
160%
Relative Luminous Flux
Forward Current (mA)
900
800
700
600
500
400
300
120%
100%
80%
60%
40%
200
20%
100
0
140%
0%
29
30
31
32
33
34
0
35
100
200
300
200%
200%
180%
180%
160%
160%
140%
140%
120%
100%
80%
60%
850
Forward Current (mA)
900
1000
60%
20%
0%
700
800
80%
40%
550
700
100%
20%
400
600
120%
40%
250
500
Figure 6 Vero 13D Typical Relative Flux vs. Current
Relative Luminous Flux
Relative Luminous Flux
Figure 5: Vero 13C Typical Relative Flux vs. Current
100
400
Forward Current (mA)
Forward Voltage (V)
1000
1150
1300
0%
0
100
200
300
400
500
600
700
800
900
1000
1100
Forward Current (mA)
Note for Figure 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
22
Performance Curves
Figure 7: Typical DC Flux vs. Case Temperature
0
103%
25
50
75
100
125
0.003
Warm White
Neutral White
100%
Cool White
0.000
25°C Pulsed
97%
-0.003
94%
ccy Shift
Relative Luminous Flux
Figure 8: Typical DC ccy Shift vs. Case Temperature
91%
-0.006
88%
-0.009
85%
-0.012
Warm White
82%
0
25
50
75
100
125
Case Temperature (°C)
-0.015
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Figure 9: Typical DC ccx Shift vs. Case Temperature
0
25
50
75
100
125
0.000
-0.002
ccx Shift
-0.004
-0.006
-0.008
Warm White
-0.010
-0.012
Neutral White
Cool White
25°C Pulsed
Case Temperature (°C)
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
23
Performance Curves
Figure 10: 2700K, 97 CRI Color Shift vs. Case Temperature1
Figure 11: 3000K, 97 CRI Color Shift vs. Case Temperature1
0.4110
0.4050
15°C
Pulsed Center
Point
Tc = 25°C
0.4100
25°C
25°C
45°C
0.4010
45°C
ccy
ccy
0.4080
Pulsed Center
Point
Tc = 25°C
15°C
0.4030
0.4090
0.4070
65°C
70°C
0.3990
0.4060
85°C
85°C
0.4050
0.3970
105°C
0.4040
105°C
0.4030
0.457
0.4572
0.4574
0.4576
0.4578
0.3950
0.4323
0.458
0.4328
0.4333
ccx
Figure 12: 3000K, 90 CRI Color Shift vs. Case Temperature3
0.4343
0.369
15°C
0.402
Pulsed Center
Point Tc=25°C
25°C
15°C
0.368
25°C
0.367
0.401
0.366
0.399
ccy
45°C
0.4
0.4348
0.4353
Figure 13: 3000K Class A Color Shift vs. Case Temperature1
0.403
ccy
0.4338
ccx
65°C
0.398
45°C
0.365
0.364
70°C
0.363
85°C
0.397
Pulsed
Center Point
Tc=25°C
85°C
0.362
105°C
0.396
0.395
0.444
0.361
0.4445
0.445
0.4455
0.446
0.4465
105°C
0.36
0.416
0.447
0.4165
0.417
ccx
0.4175
0.418
0.4185
ccx
Figure 14: 3500K Class A Color Shift vs. Case Temperature1
Figure 15: 4000K Class A Color Shift vs. Case Temperature1
0.37
0.3760
15°C
0.368
25°C
0.366
Pulsed
Center Point
Tc=25°C
15°C
0.3740
25°C
0.3720
45°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.364
0.3680
70°C
0.362
70°C
0.3660
85°C
0.36
85°C
0.3640
105°C
0.358
0.392
105°C
0.393
0.394
0.395
0.396
0.397
ccx
Note for Figures 10-15:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRC-30G200C-x-73
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
24
Typical Radiation Pattern
Figure 16: Typical Spatial Radiation Pattern
Note for Figure 16:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 17: Typical Polar Radiation Pattern
25
Typical Color Spectrum
Figure 18: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 18:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 19: Typical Color Spectrum for Vero 13 with Décor Series
1
27H
0.9
30H
30G (Décor Series Showcase)
Relative Spectral Power Distribution
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 19:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
26
Mechanical Dimensions
Figure 20: Drawing for Vero 13 LED Array
Notes for Figure 20:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
27
Color Binning Information
Figure 21: Warm and Neutral White Test Bins in xy Color
Figure 22: Cool White Test Bins in xy Color Space
Space
0.44
0.39
4 SDCM
3 SDCM
3 SDCM
0.38
2 SDCM
2700K
0.42
0.37
3000K
0.4
5000K
0.36
3500K
5700K
0.35
Y
Y
4000K
0.34
0.38
6500K
0.33
0.36
0.32
0.31
0.34
0.36
0.39
0.42
X
0.45
0.3
0.48
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
2700K
3000K1
3500K1
4000K1
ANSI Bin
(for reference only)
(2580K - 2870K)
(2870K - 3220K)
(3220K - 3710K)
(3710K - 4260K)
73 (3 SDCM)
(2651K - 2794K)
(2968K - 3136K)
(3369K - 3586K)
(3851K - 4130K)
72 (2 SDCM)
(2674K - 2769K)
(2995K - 3107K)
(3404K - 3548K)
(3895K - 4081K)
Center Point (x,y)
(0.4578, 0.4101)
(0.4338, 0.403)
(0.4465, 0.4024)2
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Décor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3287, 0.3417)
(0.3123, 0.3282)
28
Packaging and Labeling
Figure 23: Drawing for Vero 13 Packaging Tray
Notes for Figure 23:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
29
Packaging and Labeling
Figure 24: Vero Series Packaging and Labeling
Notes for Figure 24:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 25: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E2000C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
30
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
31
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 Vero 13 Array Series Product Data Sheet DS91 Rev. N (10/2018)
32