Bridgelux Gen 7 Vero 29 Array
®
®
Product Data Sheet DS93
1
Vero® Series
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing
unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color
points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color
tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums.
Décor Series Ultra is designed as a replacement for halogen lamps
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Features
• Efficacy of 170 lm/W typical
• Lumen output performance ranges from 3,850 to
38,400 lumens
• Broad range of CCT options from 1750K to 6500K
• CRI options include minimum 65, 70, 80, and 90, 2
and 3 SDCM color control for 2700K-4000K CCT
Benefits
• Broad application coverage for interior and exterior
lighting
• Flexibility for application driven lighting design
requirements
• High quality true color reproduction
• Uniform consistent white light
• Reliable operation at up to 2X nominal drive current
• Flexibility in design optimization
• Radial die pattern and improved lumen density
• Enhanced ease of use and assembly
• Thermally isolated solder pads
• Solderless connectivity enables plug & play
installation and field upgradability
• Onboard connector port
• Top side part number markings
• Vf bin code backside marking
• Improved inventory management and quality control
Contents
Product Feature Map
2
Product Nomenclature
2
Product Selection Guide
3
Performance at Commonly Used Drive Currents
10
Electrical Characteristics
20
Eye Safety
21
Absolute Maximum Ratings
22
Performance Curves
23
Typical Radiation Pattern
27
Typical Color Spectrum
28
Mechanical Dimensions
29
Color Binning Information
30
Packaging and Labeling
31
Design Resources
33
Precautions
33
Disclaimers
33
About Bridgelux
34
1
Product Feature Map
Vero 29 is the largest form factor in the Vero family of
next generation solid state light sources. In addition to
delivering the performance and light quality required
for many lighting applications, Vero incorporates several
features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
Mounting holes
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Polarity indication marks simplify
manufacturing operator instructions
Tc Measurement point
2D Bar code provides full
manufacturing traceability
Top side part number marking improves
inventory management and outgoing
quality control
Radial die configuration improves lumen
density and beam control
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Optional Molex Pico-EZmate™ connector harness
(sold separately)
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
1 2 3 4
5 6
7 8 9 10 11
–
12
– 13 14
BXRC – 30 E 10K 0 – C – 7 3
CCT Bin Options
Product Family
Nominal CCT
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
Gen. 7
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
Array Configuration
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
Flux Indicator
10Kx = 10,000 lm
2
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
BXRC-17E10K0-B-74
1750
80
1800
8611
7750
BXRC-17E10K0-C-74
1750
80
1710
10918
9826
Typical
Power
(W)
Typical
Efficacy
(lm/W)
52.0
93.6
92
69.4
118.7
92
Typical Vf
(V)
BXRC-17E10K0-D-74
1750
80
2100
7264
6538
37.6
79.0
92
BXRC-20B10K1-C-73
2000
65
1710
18632
16769
69.4
118.7
157
BXRC-20B10K1-D-73
2000
65
2100
12397
11157
37.6
79.0
157
BXRC-25E10K0-B-74
2500
80
1800
14321
12889
52.0
93.6
153
153
BXRC-25E10K0-C-74
2500
80
1710
18157
16341
69.4
118.7
BXRC-25E10K0-D-74
2500
80
2100
12081
10873
37.6
79.0
153
BXRC-27E10K0-B-7x
2700
80
1800
14976
13478
52.0
93.6
160
BXRC-27E10K0-C-7x
2700
80
1710
18988
17089
69.4
118.7
160
BXRC-27E10K0-D-7x
2700
80
2100
12634
11370
37.6
79.0
160
BXRC-27G1KH0-B-7x
2700
90
1800
12823
11541
52.0
93.6
137
BXRC-27G1KH0-C-7x
2700
90
1710
16258
14633
69.4
118.7
137
BXRC-27G1KH0-D-7x
2700
90
2100
10818
9736
37.6
79.0
137
BXRC-27G10K0-B-7x
2700
90
1800
12355
11120
52.0
93.6
132
BXRC-27G10K0-C-7x
2700
90
1710
15665
14098
69.4
118.7
132
BXRC-27G10K0-D-7x
2700
90
2100
10423
9380
37.6
79.0
132
BXRC-27H10K0-D-7x
2700
97
2100
9243
8319
37.6
79.0
117
BXRC-30C10K1-B-74
3000
70
1800
16661
14995
52.0
93.6
178
BXRC-30C10K1-C-74
3000
70
1710
21124
19012
69.4
118.7
178
BXRC-30C10K1-D-74
3000
70
2100
14055
12649
37.6
79.0
178
BXRC-30E10K0-B-7x10
3000
80
1800
15912
14321
52.0
93.6
170
BXRC-30E10K0-C-7x10
3000
80
1710
20175
18157
69.4
118.7
170
BXRC-30E10K0-D-7x10
3000
80
2100
13423
12081
37.6
79.0
170
BXRC-30G1KH0-B-7x
3000
90
1800
13478
12131
52.0
93.6
144
BXRC-30G1KH0-C-7x
3000
90
1710
17089
15380
69.4
118.7
144
BXRC-30G1KH0-D-7x
3000
90
2100
11370
10233
37.6
79.0
144
BXRC-30G10K0-B-7x
3000
90
1800
12917
11625
52.0
93.6
138
BXRC-30G10K0-C-7x
3000
90
1710
16377
14739
69.4
118.7
138
BXRC-30G10K0-D-7x
3000
90
2100
10896
9807
37.6
79.0
138
BXRC-30H10K0-D-7x
3000
97
2100
9870
8883
37.6
79.0
125
BXRC-30A10K1-B-738,9
3000
93
1800
11606
10446
52.0
93.6
124
BXRC-30A10K1-C-73
8,9
3000
93
1710
14716
13244
69.4
118.7
124
BXRC-30A10K1-D-738,9
3000
93
2100
9791
8812
37.6
79.0
124
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93.
Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
3
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7x10
3500
80
1800
16286
14658
52.0
93.6
174
BXRC-35E10K0-C-7x10
3500
80
1710
20649
18584
69.4
118.7
174
BXRC-35E10K0-D-7x10
3500
80
2100
13739
12365
37.6
79.0
174
BXRC-35G10K0-B-7x
3500
90
1800
13385
12046
52.0
93.6
143
BXRC-35G10K0-C-7x
3500
90
1710
16970
15273
69.4
118.7
143
BXRC-35G10K0-D-7x
3500
90
2100
11291
10162
37.6
79.0
143
BXRC-35A10K1-B-738,9
3500
93
1800
12355
11120
52.0
93.6
132
BXRC-35A10K1-C-738,9
3500
93
1710
15665
14098
69.4
118.7
132
BXRC-35A10K1-D-738,9
3500
93
2100
10423
9380
37.6
79.0
132
BXRC-40C10K1-B-74
4000
70
1800
17129
15416
52.0
93.6
183
BXRC-40C10K1-C-74
4000
70
1710
21717
19546
69.4
118.7
183
BXRC-40C10K1-D-74
4000
70
2100
14450
13005
37.6
79.0
183
BXRC-40E10K0-B-7x10
4000
80
1800
16380
14742
52.0
93.6
175
BXRC-40E10K0-C-7x10
4000
80
1710
20768
18691
69.4
118.7
175
BXRC-40E10K0-D-7x10
4000
80
2100
13818
12436
37.6
79.0
175
BXRC-40G10K0-B-7x
4000
90
1800
13666
12299
52.0
93.6
146
BXRC-40G10K0-C-7x
4000
90
1710
17326
15594
69.4
118.7
146
BXRC-40G10K0-D-7x
4000
90
2100
11528
10375
37.6
79.0
146
BXRC-40H10K0-D-7x
4000
97
2100
10423
9380
37.6
79.0
132
BXRC-40A10K1-B-738,9
4000
93
1800
13385
12046
52.0
93.6
143
143
BXRC-40A10K1-C-738,9
4000
93
1710
16970
15273
69.4
118.7
BXRC-40A10K1-D-738,9
4000
93
2100
11291
10162
37.6
79.0
143
BXRC-50C10K1-B-7x10
5000
70
1800
17222
15500
52.0
93.6
184
BXRC-50C10K1-C-7x10
5000
70
1710
21836
19652
69.4
118.7
184
BXRC-50C10K1-D-7x10
5000
70
2100
14529
13076
37.6
79.0
184
BXRC-50E10K1-B-7x
5000
80
1800
16567
14910
52.0
93.6
177
BXRC-50E10K1-C-7x
5000
80
1710
21005
18905
69.4
118.7
177
BXRC-50E10K1-D-7x
5000
80
2100
13976
12578
37.6
79.0
177
BXRC-50G10K1-B-7x
5000
90
1800
14321
12889
52.0
93.6
153
BXRC-50G10K1-C-7x
5000
90
1710
18157
16341
69.4
118.7
153
BXRC-50G10K1-D-7x
5000
90
2100
12081
10873
37.6
79.0
153
BXRC-56G10K0-B-74
5600
90
1800
14414
12973
52.0
93.6
154
154
BXRC-56G10K0-C-74
5600
90
1710
18276
16448
69.4
118.7
BXRC-56G10K0-D-74
5600
90
2100
12160
10944
37.6
79.0
154
BXRC-56H10K1-D-74
5600
97
2100
10975
9878
37.6
79.0
139
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-57C10K1-B-7x10
5700
70
1800
16754
15079
52.0
93.6
179
BXRC-57C10K1-C-7x10
5700
70
1710
21243
19118
69.4
118.7
179
BXRC-57C10K1-D-7x10
5700
70
2100
14134
12720
37.6
79.0
179
BXRC-57E10K1-B-7x10
5700
80
1800
15912
14321
52.0
93.6
170
BXRC-57E10K1-C-7x10
5700
80
1710
20175
18157
69.4
118.7
170
BXRC-57E10K1-D-7x10
5700
80
2100
13423
12081
37.6
79.0
170
BXRC-65C10K1-B-7x10
6500
70
1800
16754
15079
52.0
93.6
179
BXRC-65C10K1-C-7x10
6500
70
1710
21243
19118
69.4
118.7
179
BXRC-65C10K1-D-7x10
6500
70
2100
14134
12720
37.6
79.0
179
BXRC-65E10K1-B-7x10
6500
80
1800
16099
14489
52.0
93.6
172
BXRC-65E10K1-C-7x10
6500
80
1710
20412
18371
69.4
118.7
172
BXRC-65E10K1-D-7x10
6500
80
2100
13581
12223
37.6
79.0
172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93.
Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
10. SKUs can meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions.
5
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2
CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A10K1-B-73
3000
80
93
1800
10794
9715
50.9
91.6
118
118
BXRC-30A10K1-C-73
3000
80
93
1710
13685
12317
67.9
116.1
BXRC-30A10K1-D-73
3000
80
93
2100
9106
8195
36.8
77.3
118
BXRC-35A10K1-B-73
3500
80
93
1800
11490
10341
50.9
91.6
125
126
BXRC-35A10K1-C-73
3500
80
93
1710
14568
13112
67.9
116.1
BXRC-35A10K1-D-73
3500
80
93
2100
9693
8724
36.8
77.3
125
BXRC-40A10K1-B-73
4000
80
93
1800
12448
11203
50.9
91.6
136
BXRC-40A10K1-C-73
4000
80
93
1710
15782
14204
67.9
116.1
136
BXRC-40A10K1-D-73
4000
80
93
2100
10501
9451
36.8
77.3
136
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
85
BXRC-17E10K0-B-74
1750
80
1800
7750
6975
50.7
91.2
BXRC-17E10K0-C-74
1750
80
1710
9826
8844
68.1
116.4
84
BXRC-17E10K0-D-74
1750
80
2100
6538
5884
36.6
76.8
85
BXRC-20B10K0-C-73
2000
65
1710
16769
15092
68.1
116.4
144
BXRC-20B10K0-D-73
2000
65
2100
11157
10041
36.6
76.8
145
BXRC-25E10K0-B-74
2500
80
1800
12889
11600
50.7
91.2
141
BXRC-25E10K0-C-74
2500
80
1710
16341
14707
68.1
116.4
140
BXRC-25E10K0-D-74
2500
80
2100
10873
9786
36.6
76.8
142
BXRC-27E10K0-B-7x
2700
80
1800
13478
12131
50.7
91.2
148
BXRC-27E10K0-C-7x
2700
80
1710
17089
15380
68.1
116.4
147
BXRC-27E10K0-D-7x
2700
80
2100
11370
10233
36.6
76.8
148
BXRC-27G1KH0-B-7x
2700
90
1800
11541
10387
51.0
91.7
126
BXRC-27G1KH0-C-7x
2700
90
1710
14633
13169
68.4
116.9
125
BXRC-27G1KH0-D-7x
2700
90
2100
9736
8762
36.6
76.8
127
121
BXRC-27G10K0-B-7x
2700
90
1800
11120
10008
51.0
91.7
BXRC-27G10K0-C-7x
2700
90
1710
14098
12689
68.4
116.9
121
BXRC-27G10K0-D-7x
2700
90
2100
9380
8442
36.6
76.8
122
BXRC-27H10K0-D-7x
2700
97
2100
8319
7487
36.6
76.8
108
BXRC-30C10K1-B-74
3000
70
1800
14995
13495
51.0
91.7
163
BXRC-30C10K1-C-74
3000
70
1710
19012
17110
68.4
116.9
163
BXRC-30C10K1-D-74
3000
70
2100
12649
11384
36.6
76.8
165
BXRC-30E10K0-B-7x
3000
80
1800
14321
12889
51.0
91.7
156
BXRC-30E10K0-C-7x
3000
80
1710
18157
16341
68.4
116.9
155
BXRC-30E10K0-D-7x
3000
80
2100
12081
10873
36.6
76.8
157
BXRC-30G1KH0-B-7x
3000
90
1800
12131
10918
51.0
91.7
132
BXRC-30G1KH0-C-7x
3000
90
1710
15380
13842
68.4
116.9
132
BXRC-30G1KH0-D-7x
3000
90
2100
10233
9210
36.6
76.8
133
127
BXRC-30G10K0-B-7x
3000
90
1800
11625
10463
50.7
91.2
BXRC-30G10K0-C-7x
3000
90
1710
14739
13265
68.1
116.4
127
BXRC-30G10K0-D-7x
3000
90
2100
9807
8826
36.6
76.8
128
BXRC-30H10K0-D-7X
3000
97
2100
8883
7995
36.6
76.9
116
BXRC-30A10K1-B-737,8
3000
93
1800
10446
9401
50.7
91.2
115
BXRC-30A10K1-C-737,8
3000
93
1710
13244
11920
68.1
116.4
114
BXRC-30A10K1-D-737,8
3000
93
2100
8812
7931
36.6
76.8
115
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-35E10K0-B-7X
3500
80
1800
14658
13192
50.7
91.2
161
BXRC-35E10K0-C-7X
3500
80
1710
18584
16726
68.1
116.4
160
BXRC-35E10K0-D-7X
3500
80
2100
12365
11129
36.6
76.8
161
BXRC-35G10K0-B-7X
3500
90
1800
12046
10842
50.7
91.2
132
BXRC-35G10K0-C-7X
3500
90
1710
15273
13746
68.1
116.4
131
BXRC-35G10K0-D-7X
3500
90
2100
10162
9146
36.6
76.8
132
BXRC-35A10K1-B-737,8
3500
93
1800
11120
10008
50.7
91.2
122
BXRC-35A10K1-C-737,8
3500
93
1710
14098
12689
68.1
116.4
121
BXRC-35A10K1-D-73
3500
93
2100
9380
8442
36.6
76.8
122
BXRC-40C10K1-B-74
4000
70
1800
15416
13874
51.0
91.7
168
7,8
BXRC-40C10K1-C-74
4000
70
1710
19546
17591
68.4
116.9
167
BXRC-40C10K1-D-74
4000
70
2100
13005
11704
36.6
76.8
169
162
BXRC-40E10K0-B-7X
4000
80
1800
14742
13268
50.7
91.2
BXRC-40E10K0-C-7X
4000
80
1710
18691
16822
68.1
116.4
161
BXRC-40E10K0-D-7X
4000
80
2100
12436
11193
36.6
76.8
162
135
BXRC-40G10K0-B-7X
4000
90
1800
12299
11069
50.7
91.2
BXRC-40G10K0-C-7X
4000
90
1710
15594
14034
68.1
116.4
134
BXRC-40G10K0-D-7X
4000
90
2100
10375
9338
36.6
76.8
135
BXRC-40H10K0-D-7x
4000
97
2100
9380
8442
36.6
76.9
122
BXRC-40A10K1-B-737,8
4000
93
1800
12046
10842
50.7
91.2
132
BXRC-40A10K1-C-737,8
4000
93
1710
15273
13746
68.1
116.4
131
BXRC-40A10K1-D-737,8
4000
93
2100
10162
9146
36.6
76.8
132
BXRC-50C10K1-B-7x
5000
70
1800
15500
13950
50.7
91.2
170
BXRC-50C10K1-C-7x
5000
70
1710
19652
17687
68.1
116.4
169
BXRC-50C10K1-D-7x
5000
70
2100
13076
11768
36.6
76.8
170
BXRC-50E10K1-B-7x
5000
80
1800
14910
13419
50.7
91.2
163
BXRC-50E10K1-C-7x
5000
80
1710
18905
17014
68.1
116.4
162
BXRC-50E10K1-D-7x
5000
80
2100
12578
11320
36.6
76.8
164
BXRC-50G10K1-B-7x
5000
90
1800
12889
11600
50.7
91.2
141
BXRC-50G10K1-C-7x
5000
90
1710
16341
14707
68.1
116.4
140
BXRC-50G10K1-D-7x
5000
90
2100
10873
9786
36.6
76.8
142
BXRC-56G10K0-B-74
5600
90
1800
12973
11676
50.7
91.2
142
BXRC-56G10K0-C-74
5600
90
1710
16448
14803
68.1
116.4
141
BXRC-56G10K0-D-74
5600
90
2100
10944
9849
36.6
76.8
143
BXRC-56H10K1-D-74
5600
97
2100
9878
8890
36.6
76.9
129
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Class A, Decor Series Street and Landmark and Décor Series Ultra
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number
Nominal CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
165
BXRC-57C10K1-B-7x
5700
70
1800
15079
13571
50.7
91.2
BXRC-57C10K1-C-7x
5700
70
1710
19118
17207
68.1
116.4
164
BXRC-57C10K1-D-7x
5700
70
2100
12720
11448
36.6
76.8
166
BXRC-57E10K1-B-7x
5700
80
1800
14321
12889
50.7
91.2
157
BXRC-57E10K1-C-7x
5700
80
1710
18157
16341
68.1
116.4
156
BXRC-57E10K1-D-7x
5700
80
2100
12081
10873
36.6
76.8
157
165
BXRC-65C10K1-B-7x
6500
70
1800
15079
13571
50.7
91.2
BXRC-65C10K1-C-7x
6500
70
1710
19118
17207
68.1
116.4
164
BXRC-65C10K1-D-7x
6500
70
2100
12720
11448
36.6
76.8
166
BXRC-65E10K1-B-7x
6500
80
1800
14489
13040
50.7
91.2
159
BXRC-65E10K1-C-7x
6500
80
1710
18371
16534
68.1
116.4
158
BXRC-65E10K1-D-7x
6500
80
2100
12223
11001
36.6
76.8
159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Décor Series Class A, Decor Series Street and Landmark and Décor Series Ultra
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
9
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number
CRI
BXRC-17E10K0-B-74
80
BXRC-17E10K0-C-74
80
BXRC-17E10K0-D-74
80
BXRC-20B10K0-C-73
65
BXRC-20B10K0-D-73
65
BXRC-25E10K0-B-74
80
BXRC-25E10K0-C-74
80
BXRC-25E10K0-D-74
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.7
78.9
124.4
173.0
4470
5886
8611
12413
15887
5665
7473
10918
15717
20113
3670
4854
7264
10608
13861
9667
12752
18632
26822
34323
6263
8283
12397
18102
23654
7434
9789
14321
20643
26421
9421
12427
18157
26138
33448
6103
8072
12081
17641
23051
4081
5350
7750
11070
13998
5176
6794
9826
13846
17281
3353
4413
6538
9345
11910
8832
11594
16769
23628
29491
5722
7530
11157
15947
20324
6786
8898
12889
18410
23279
8607
11298
16341
23026
28739
5576
7339
10873
15540
19806
100
97
92
85
79
100
97
92
85
79
99
96
92
85
80
171
166
157
145
135
168
163
157
145
137
166
162
153
141
131
167
162
153
141
131
164
159
153
142
133
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
10
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27E10K0-B-7x
80
BXRC-27E10K0-C-7x
80
BXRC-27E10K0-D-7x
80
BXRC-27G1KH0-B-7x
90
BXRC-27G1KH0-C-7x
90
BXRC-27G1KH0-D-7x
90
BXRC-27G10K0-B-7x
90
BXRC-27G10K0-C-7x
90
BXRC-27G10K0-D-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
7774
10237
14976
21588
27630
9852
12996
18988
27334
34979
6382
8441
12634
18448
24106
6657
8765
12823
18484
23658
8436
11128
16258
23405
29951
5465
7228
10818
15796
20641
6414
8445
12355
17810
22795
8128
10721
15665
22551
28857
5265
6964
10423
15220
19888
7097
9305
13478
19252
24344
9001
11815
17089
24080
30054
5831
7674
11370
16251
20712
6076
7968
11541
16485
20844
7707
10117
14633
20618
25734
4993
6571
9736
13915
17735
5855
7677
11120
15883
20084
7426
9747
14098
19866
24795
4811
6331
9380
13407
17088
174
169
160
148
137
174
169
160
148
137
172
167
160
148
139
149
145
137
127
118
149
145
137
127
118
147
143
137
127
119
144
139
132
122
113
144
140
132
122
113
142
138
132
122
115
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-27H10K0-D-7x
97
BXRC-30C10K1-B-74
70
BXRC-30C10K1-C-74
70
BXRC-30C10K1-D-74
70
BXRC-30E10K0-B-7x
80
BXRC-30E10K0-C-7x
80
BXRC-30E10K0-D-7x
80
BXRC-30G1KH0-B-7X
90
BXRC-30G1KH0-C-7x
90
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
4669
6176
9243
13497
17637
9464
12029
16661
23635
29625
10960
14458
21124
30409
38914
7100
9391
14055
20523
26818
8260
10876
15912
22937
29357
10468
13808
20175
29043
37165
6781
8969
13423
19601
25613
6997
9213
13478
19429
24867
8867
11696
17089
24601
31481
4266
5615
8319
11890
15154
9006
11096
14995
20328
24893
10014
13144
19012
26789
33435
6487
8538
12649
18080
23042
7540
9887
14321
20455
25865
9564
12554
18157
25585
31933
6195
8154
12081
17267
22007
6387
8375
12131
17327
21909
8101
10634
15380
21672
27049
125
122
117
109
102
212
199
178
162
147
194
188
178
164
153
191
185
178
165
155
185
180
170
157
146
185
180
170
157
146
182
177
170
158
148
157
152
144
133
124
157
152
144
133
124
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-30G1KH0-D-7x
90
BXRC-30G10K0-B-7x
90
BXRC-30G10K0-C-7x
90
BXRC-30G10K0-D-7x
90
BXRC-30H10K0-D-7x
97
BXRC-30A10K1-B-73
93
BXRC-30A10K1-C-73
93
BXRC-30A10K1-D-73
93
BXRC-35E10K0-B-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
5744
7597
11370
16603
21695
6705
8829
12917
18619
23831
8497
11209
16377
23576
30169
5505
7280
10896
15911
20792
4986
6595
9870
14412
18833
6025
7933
11606
16730
21413
7635
10072
14716
21184
27109
4946
6542
9791
14297
18682
8455
11132
16286
23477
30047
5248
6907
10233
14626
18641
6121
8026
11625
16605
20997
7763
10191
14739
20769
25922
5029
6619
9807
14017
17864
4555
5996
8883
12696
16182
5500
7212
10446
14920
18867
6976
9157
13244
18662
23292
4519
5948
8812
12595
16052
7718
10119
14658
20937
26474
154
150
144
134
125
150
146
138
127
119
150
146
138
127
119
148
144
138
128
120
134
130
125
116
109
135
131
124
115
107
135
131
124
115
106
133
129
124
115
108
189
184
174
161
149
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-35E10K0-C-7x
80
BXRC-35E10K0-D-7x
80
BXRC-35G10K0-B-7x
90
BXRC-35G10K0-C-7x
90
BXRC-35G10K0-D-7x
90
BXRC-35A10K1-B-73
93
BXRC-35A10K1-C-73
93
BXRC-35A10K1-D-73
93
BXRC-40C10K1-B-74
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
10714
14133
20649
29726
38039
6941
9180
13739
20062
26215
6948
9149
13385
19294
24694
8805
11615
16970
24430
31262
5704
7544
11291
16488
21545
6414
8445
12355
17810
22795
8128
10721
15665
22551
28857
5265
6964
10423
15220
19888
8892
11708
17129
24691
31602
9789
12849
18584
26187
32684
6341
8346
12365
17673
22525
6343
8317
12046
17207
21757
8045
10560
15273
21521
26861
5211
6859
10162
14525
18512
5855
7677
11120
15883
20084
7426
9747
14098
19866
24795
4811
6331
9380
13407
17088
8117
10643
15416
22020
27843
189
184
174
161
149
187
181
174
161
152
156
151
143
132
123
156
151
143
132
123
153
149
143
133
125
144
139
132
122
113
144
140
132
122
113
142
138
132
122
115
199
193
183
169
157
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40C10K1-C-74
70
BXRC-40C10K1-D-74
70
BXRC-40E10K0-B-7x
80
BXRC-40E10K0-C-7x
80
BXRC-40E10K0-D-7x
80
BXRC-40G10K0-B-7X
90
BXRC-40G10K0-C-7X
90
BXRC-40G10K0-D-7X
90
BXRC-40H10K0-D-7x
97
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
11268
14864
21717
31263
40007
7300
9654
14450
21100
27571
8503
11196
16380
23611
30220
10776
14214
20768
29897
38258
6981
9232
13818
20177
26366
7094
9341
13666
19699
25212
8990
11859
17326
24942
31918
5824
7702
11528
16834
21997
5265
6964
10423
15220
19888
10295
13514
19546
27541
34375
6669
8777
13005
18587
23690
7762
10178
14742
21057
26626
9845
12923
18691
26337
32872
6378
8394
12436
17775
22654
6476
8491
12299
17568
22214
8213
10781
15594
21973
27425
5321
7003
10375
14829
18900
4811
6331
9380
13407
17088
199
194
183
169
157
196
191
183
170
159
190
185
175
162
150
190
185
175
162
150
188
182
175
162
152
159
154
146
135
125
159
155
146
135
125
157
152
146
135
127
142
138
132
122
115
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-40A10K1-B-73
93
BXRC-40A10K1-C-73
93
BXRC-40A10K1-D-73
93
BXRC-50C10K1-B-7x
70
BXRC-50C10K1-C-7x
70
BXRC-50C10K1-D-7x
70
BXRC-50E10K1-B-7x
80
BXRC-50E10K1-C-7x
80
BXRC-50E10K1-D-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
6948
9149
13385
19294
24694
8805
11615
16970
24430
31262
5704
7544
11291
16488
21545
8941
11772
17222
24826
31774
11330
14945
21836
31434
40226
7340
9707
14529
21215
27722
8600
11324
16567
23881
30565
10899
14376
21005
30238
38695
7060
9338
13976
20408
26667
6343
8317
12046
17207
21757
8045
10560
15273
21521
26861
5211
6859
10162
14525
18512
8161
10701
15500
22140
27995
10351
13587
19652
27691
34562
6706
8825
13076
18689
23819
7851
10294
14910
21298
26930
9957
13070
18905
26638
33248
6450
8490
12578
17978
22913
156
151
143
132
123
156
151
143
132
123
153
149
143
133
125
200
194
184
170
158
200
195
184
170
158
197
192
184
171
160
193
187
177
164
152
193
187
177
163
152
190
184
177
164
154
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-50G10K1-B-7x
90
BXRC-50G10K1-C-7x
90
BXRC-50G10K1-D-7x
90
BXRC-56G10K0-B-7x
80
BXRC-56G10K0-C-7x
80
BXRC-56G10K0-D-7x
80
BXRC-56H10K1-D-74
97
BXRC-57C10K1-B-7x
70
BXRC-57C10K1-C-7x
70
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7434
9789
14321
20643
26421
9421
12427
18157
26138
33448
6103
8072
12081
17641
23051
7483
9853
14414
20778
26594
9483
12508
18276
26309
33667
6143
8125
12160
17756
23202
5545
7333
10975
16027
20942
8698
11452
16754
24151
30911
11022
14539
21243
30580
39132
6786
8898
12889
18410
23279
8607
11298
16341
23026
28739
5576
7339
10873
15540
19806
6831
8956
12973
18530
23431
8663
11372
16448
23177
28927
5612
7386
10944
15642
19936
5066
6667
9878
14118
17994
7939
10410
15079
21538
27235
10070
13218
19118
26939
33623
166
162
153
141
131
167
162
153
141
131
164
159
153
142
133
168
163
154
142
132
168
163
154
142
132
165
160
154
143
134
149
145
139
129
121
195
189
179
165
154
195
190
179
165
154
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
CRI
BXRC-57C10K1-D-7x
70
BXRC-57E10K1-B-7x
80
BXRC-57E10K1-C-7x
80
BXRC-57E10K1-D-7x
80
BXRC-65C10K1-B-7x
70
BXRC-65C10K1-C-7x
70
BXRC-65C10K1-D-7x
70
BXRC-65E10K1-B-7x
80
BXRC-65E10K1-C-7x
80
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
1050
1400
2100
3150
4200
900
1200
1800
2700
3600
855
1140
1710
2565
3420
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
35.4
36.2
37.6
39.5
41.2
49.6
50.5
52.0
54.1
55.8
66.2
67.3
69.4
72.1
74.4
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
37.2
50.6
79.0
124.4
172.9
44.7
60.6
93.6
146.1
201.0
56.6
76.7
118.7
185.0
254.6
7140
9443
14134
20639
26969
8260
10876
15912
22937
29357
10468
13808
20175
29043
37165
6781
8969
13423
19601
25613
8698
11452
16754
24151
30911
11022
14539
21243
30580
39132
7140
9443
14134
20639
26969
8357
11004
16099
23207
29702
10591
13970
20412
29384
37602
6523
8586
12720
18181
23172
7540
9887
14321
20455
25865
9564
12554
18157
25585
31933
6195
8154
12081
17267
22007
7939
10410
15079
21538
27235
10070
13218
19118
26939
33623
6523
8586
12720
18181
23172
7629
10003
14489
20696
26170
9676
12701
18371
25886
32308
192
186
179
166
156
185
180
170
157
146
185
180
170
157
146
182
177
170
158
148
195
189
179
165
154
195
190
179
165
154
192
186
179
166
156
187
182
172
159
148
187
182
172
159
148
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number
BXRC-65E10K1-D-7x
CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
80
1050
1400
2100
3150
4200
35.4
36.2
37.6
39.5
41.2
37.2
50.6
79.0
124.4
172.9
6861
9074
13581
19831
25914
6268
8250
12223
17470
22266
184
179
172
159
150
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
19
Electrical Characteristics
Table 5: Electrical Characteristics
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8
Part Number
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
Drive Current
(mA)
Typical
Coefficient
of Forward
Voltage4
∆Vf/∆Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
0.06
46.1
57.5
-24.9
0.07
49.7
61.6
74.6
-33.2
0.04
61.5
76.8
74.4
80.0
-33.2
0.05
66.2
82.2
34.8
37.6
40.4
-17.4
0.06
33.4
41.6
38.1
41.2
44.3
-17.4
0.07
36.7
45.4
Minimum
Typical
Maximum
1800
48.1
52.0
55.9
-24.9
3600
51.7
55.8
60.0
1710
64.2
69.4
3420
68.8
2100
4200
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application.
20
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
CCT1,5
Drive
Current 5
(mA)
2700K/3000K
4000K2
5000K3
6500K4
1800
RG1
RG1
RG1
RG1
2700
RG1
RG1
RG2
RG2
3600
RG1
RG1
RG2
RG2
1710
RG1
RG1
RG1
RG2
2565
RG1
RG1
RG2
RG2
3420
RG1
RG2
RG2
RG2
2100
RG1
RG1
RG1
RG1
3150
RG1
RG1
RG1
RG2
4200
RG1
RG1
RG2
RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed
.
21
Absolute Maximum Ratings
Table 7: Maximum Ratings
Parameter
Maximum Rating
LED Junction Temperature (Tj)
150°C
Storage Temperature
-40°C to +105°C
Operating Case Temperature1 (Tc)
105°C
Soldering Temperature2
300°C or lower for a maximum of 6 seconds
BXRC-xxx10Kx-B-7x
BXRC-xxx10Kx-C-7x
BXRC-xxx10Kx-D-7x
Maximum Drive Current3
3600mA
3420mA
4200mA
Maximum Peak Pulsed Drive Current4,5
5140mA
4890mA
6000mA
Maximum Reverse Voltage6
-90V
-120V
-65V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Per IEC 62031, LED Modules for General Lighting - Safety Specifications, the maximum allowable current when using the Molex Pico Connector
is 3150mA.
5. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
6. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
22
Performance Curves
Figure 2: Vero 29C Drive Current vs. Voltage
4000
4000
3500
3500
3000
3000
Forward Current (mA)
Forward Current (mA)
Figure 1: Vero 29B Drive Current vs. Voltage
2500
2000
1500
1000
2500
2000
1500
1000
500
0
500
47
48
49
50
51
52
53
54
55
56
57
0
58
63
64
65
66
67
68
Forward Voltage (V)
Figure 3: Vero 29D Drive Current vs. Voltage
71
72
73
74
75
76
200%
180%
4000
160%
Relative Luminous Flux
3500
Forward Current (mA)
70
Figure 4: Vero 29B Typical Relative Flux vs. Current
4500
3000
2500
2000
1500
1000
140%
120%
100%
80%
60%
40%
500
0
69
Forward Voltage (V)
20%
33
34
35
36
37
38
39
40
41
42
0%
0
Forward Voltage (V)
500
1000
1500
2000
2500
3000
3500
4000
Forward Current (mA)
Figure 6: Vero 29D Typical Relative Flux vs. Current
200%
200%
180%
180%
160%
160%
140%
140%
Relative Luminous Flux
Relative Luminous Flux
Figure 5: Vero 29C Typical Relative Flux vs. Current
120%
100%
80%
60%
120%
100%
80%
60%
40%
40%
20%
20%
0%
0
400
800
1200
1600
2000
2400
Forward Current (mA)
2800
3200
3600
4000
0%
0
500
1000
1500
2000
2500
3000
3500
4000
4500
Forward Current (mA)
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
23
Performance Curves
Figure 8: Typical DC ccy Shift vs. Case Temperature
Figure 7: Typical DC Flux vs. Case Temperature
103%
Neutral White
100%
25°C Pulsed
25
50
75
100
125
-0.003
94%
91%
-0.006
-0.009
88%
Warm White
-0.012
85%
82%
0
0.000
Cool White
97%
ccy Shift
Relative Luminous Flux
0.003
Warm White
-0.015
0
25
50
75
100
Neutral White
Cool White
25°C Pulsed
125
Case Temperature (°C)
Case Temperature (°C)
Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 9: Typical DC ccx Shift vs. Case Temperature
0.4101
0.000
0
25
50
75
100
0.41
125
0.4099
0.4098
-0.002
Pulsed Center
Point Tc=25°C
15°C
25°C
0.4097
ccy
ccx Shift
-0.004
-0.006
65°C
0.4093
Warm White
-0.012
0.4095
0.4094
-0.008
-0.010
45°C
0.4096
Neutral White
85°C
0.4092
Cool White
25°C Pulsed
105°C
0.4091
Case Temperature (°C)
0.409
0.525
0.526
0.527
0.528
0.529
0.53
0.531
0.532
ccx
Notes for Figures 7 - 9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
24
Performance Curves
Figure 12: 2500K Color Shift vs. Case Temperature1
Figure 11: 1750K Color Shift vs. Case Temperature1
0.3705
0.4145
Pulsed Center Point
Tc = 25°C
15°C
0.37
15°C
0.414
25°C
0.4135
25°C
0.413
0.3695
0.369
ccy
ccy
45°C
85°C
0.411
105°C
0.5198
0.52
70°C
85°C
0.4115
0.3685
0.368
0.5196
45°C
0.4125
0.412
70°C
0.5202
0.5204
105°C
0.4105
0.468
0.5206
0.47
0.472
0.474
0.369
15°C
0.342
0.34
0.367
0.332
70°C
0.33
0.365
0.364
70°C
0.363
85°C
0.328
Pulsed
Center Point
Tc=25°C
45°C
45°C
0.334
ccy
ccy
25°C
0.366
0.336
0.326
0.368
Pulsed Center
Point
Tc = 25°C
25°C
0.338
0.478
Figure 14: 3000K, Class A Color Shift vs. Case Temperature1
0.344
15°C
0.476
ccx
ccx
Figure 13: 5600K Color Shift vs. Case Temperature1,3
Pulsed
Center Point
Tc = 25°C
85°C
0.362
105°C
0.361
0.324
0.322
0.32
0.322
0.324
0.326
0.328
105°C
0.36
0.416
0.33
0.4165
0.417
ccx
Figure 15: 3500K, Class A Color Shift vs. Case Temperature1
ccx
0.4175
0.418
0.4185
Figure 16: 4000K, Class A Color Shift vs. Case Temperature1
0.37
0.3760
15°C
0.368
Pulsed
Center Point
Tc=25°C
25°C
0.366
15°C
0.3740
25°C
0.3720
45°C
45°C
ccy
0.3700
ccy
Pulsed
Center Point
Tc=25°C
0.364
0.3680
70°C
0.362
85°C
0.36
85°C
0.3640
105°C
0.358
0.392
70°C
0.3660
105°C
0.393
0.394
0.395
0.396
0.397
ccx
0.3620
0.373
0.374
0.375
0.376
ccx
0.377
0.378
0.379
Note for Figures 10-16:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
25
Performance Curves
Figure 17: Vero 29D Drive Current Derating Curve
4400
Drive Current (mA)
4200
4000
3960
3800
3600
3400
Max Drive Current
LM-80 Max Drive Current
3200
0
10
20
30
40
50
60
70
80
90
100
110
Case Temperature (⁰C)
Notes for Figure 17:
1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product
Feature Map (page 2) for the location of the Tc Point
2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections.
3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included
in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report.
26
Typical Radiation Pattern
Figure 18: Typical Spatial Radiation Pattern
Note for Figure 18:
1. Typical viewing angle is 120⁰.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
Figure 19: Typical Polar Radiation Pattern
27
Typical Color Spectrum
Figure 20: Typical Color Spectrum
110%
3000K
100%
4000K
5000K
Relative Spectral Power Distribution
90%
6500K
80%
70%
60%
50%
40%
30%
20%
10%
0%
400
450
500
550
600
650
700
750
800
Wavelength (nm)
Note for Figure 20:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
Figure 21: Typical Color Spectrum for Vero 29 with Décor Series
1
17E
20B
0.9
25E
27H
Relative Spectral Power Distribution
0.8
30H
56G
0.7
56H
0.6
0.5
0.4
0.3
0.2
0.1
0
400
450
500
550
600
Wavelength (nm)
650
700
750
800
Note for Figure 21:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
28
Mechanical Dimensions
Figure 22: Drawing for Vero 29 LED Array
Notes for Figure 22:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ± 0.10mm.
4. Mounting holes (4X) are for M3 screws.
5. Bridgelux recommends four tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
29
Color Binning Information
Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space
0.44
2500K
4SDCM
3 SDCM
4 SDCM
2000K
3SDCM
2700K
0.42
3000K
3500K
0.4
Y
4000K
1750K
4SDCM
0.38
0.36
0.34
0.36
0.39
0.42
0.45
X
0.48
0.51
0.54
Note: Pulsed Test Conditions, Tc = 25°C
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code
1750K
2000K
2500K
2700K
ANSI Bin
(for reference only)
-
-
-
(2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM)
-
-
-
(2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
72 (2 SDCM)
-
-
-
(2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)
Center Point (x,y)
(0.5167, 0.366)
(0.5280, 0.4100)
(0.4765, 0.4137)
(0.4578, 0.4101)
3000K1
(0.4338, 0.403)
3500K1
4000K1
(0.4073, 0.3917)
(0.3818, 0.3797)
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
Figure 24: Graph of Cool White Test Bins in xy Color Space
0.39
4 SDCM
3 SDCM
0.38
0.37
5000K
0.36
5700K
Y
0.35
0.34
6500K
0.33
0.32
0.31
0.3
0.3
0.31
0.32
0.33
0.34
0.35
0.36
X
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Bin Code
5000K
5600K1
5700K
6500K
ANSI Bin (for reference only)
(4745K - 5311K)
(5310K - 6020K)
(5312K - 6022K)
(6022K - 7042K)
74 (4 SDCM)
(4801K - 5282K)
(5475K - 5830K)
(5829K - 5481K)
(6270K - 6765K)
73 (3 SDCM)
(4835K - 5215K)
(5490K - 5820K)
(5490K - 5820K)
(6250K - 6745K)
Center Point (x,y)
(0.3447, 0.3553)
(0.3293, 0.3423)
(0.3287, 0.3417)
(0.3123, 0.3282)
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
30
Packaging and Labeling
Figure 25: Drawing for Vero 29 Packaging Tray
Notes for Figure 25:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
31
Packaging and Labeling
Figure 26: Vero Series Packaging and Labeling
Notes for Figure 26:
1. Each tray holds 50 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 27: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number
30E10K0C 73 2F
Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
32
Design Resources
Application Notes
3D CAD Models
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
Optical Source Models
LM80
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales representative for LM-80 report.
Precautions
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
Disclaimers
MINOR PRODUCT CHANGE POLICY
STANDARD TEST CONDITIONS
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
Unless otherwise stated, array testing is performed
at the nominal drive current.
33
About Bridgelux: Bridging Light and Life™
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering
products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
© 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners..
Bridgelux Gen 7 Vero 29 Array Series Product Data Sheet DS93 Rev. R (09/2020)
34