0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-40E10K0-C-73-SE

BXRC-40E10K0-C-73-SE

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVEROSE4000KROUND

  • 数据手册
  • 价格&库存
BXRC-40E10K0-C-73-SE 数据手册
Bridgelux Vero SE 29 Array ® ® Product Data Sheet DS123 1 Vero SE Introduction Vero® SE Series is a revolutionary light source system that integrates Bridgelux’s seventh generation COB technology with poke-in connectivity enabling solder-free installation. Vero SE LED light sources streamline assembly processes, lower manufacturing cost, simplify luminaire design, improve light quality and increase design flexibility. Vero SE is available in four different light emitting surface (LES) configurations that operate reliably over a broad current range. With Vero SE, secondary connector and holder components are not required, allowing for rapid integration of arrays into fixtures and an efficient field replaceable solution. Vero SE arrays deliver increased lumen density for improved beam control and precision lighting with 2 and 3 SDCM color control standards for clean and consistent uniform lighting. Bridgelux Décor Series is our state of the art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and offer pleasing and inspiring lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series Food products are a must have for any butcher counter or bakery. Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these industries. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Features • Poke-in connectivity • Efficacy of 159 lm/W typical • Lumen output performance ranges from 5,368 to 37,173 lumens Benefits • Poke-in connectivity enables solderless, connector free installation • Broad application coverage for interior and exterior lighting • Broad range of CCT options from 1750K to 6500K • Flexibility for application driven lighting design requirements • CRI options: minimum 65, 70, 80, and 90 • High quality, true color reproduction • Color control: 2 and 3 SDCM for 2700K-4000K CCT • Uniform consistent white light • Reliable operation at up to 2X nominal drive current • Flexibility in design optimization • Radial die pattern and improved lumen density • Enhanced ease of use and assembly • Top side part number markings • No exposed solder pads or electrical connections • Ability to configure multiple arrays in series and parallel reduces customer driver cost • Vf bin code backside marking • Improved inventory management and quality control Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 20 Eye Safety 21 Absolute Maximum Ratings 22 Performance Curves 23 Typical Radiation Pattern 27 Typical Color Spectrum 28 Mechanical Dimensions 29 Color Binning Information 30 Packaging and Labeling 31 Design Resources 33 Precautions 33 Disclaimers 33 About Bridgelux 34 1 Product Feature Map Vero SE 29 is the largest form factor in the product family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero SE incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero SE Series family of products. 2D Bar code provides full manufacturing traceability Polarity indication marks simplify manufacturing operator instructions Wire release mechanisms x4 Tc Measurement point Optic mounting holes Radial die configuration improves lumen density and beam control Mounting holes Top side part number marking improves inventory management and outgoing quality control Test ports for probing Dual poke-in connectivity Product Nomenclature The part number designation for Bridgelux Vero SE LED arrays is explained as follows: 1 2 3 4 – 5 6 7 8 9 10 11 – 12 – 13 14 – 15 16 BXRC – 30 E 10K 0 – C – 7 3 – SE Product Family Nominal CCT 17 = 1,750K 20 = 2,000K 25 = 2,500K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 56 = 5,600K 57 = 5,700K 65 = 6,500K Special Edition CCT Bin Options Gen. 7 Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. A = Class A 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted Flux Indicator 10Kx = 10,000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-74-SE 1750 80 1800 8237 7413 52.0 93.6 88 BXRC-17E10K0-C-74-SE 1750 80 1710 10443 9399 69.4 118.7 88 BXRC-17E10K0-D-74-SE 1750 80 2100 6948 6254 37.6 79.0 88 BXRC-20B10K1-C-73-SE 2000 65 1710 17682 15914 69.4 118.7 149 BXRC-20B10K1-D-73-SE 2000 65 2100 11765 10589 37.6 79.0 149 BXRC-25E10K0-B-74-SE 2500 80 1800 13385 12046 52.0 93.6 143 BXRC-25E10K0-C-74-SE 2500 80 1710 16970 15273 69.4 118.7 143 BXRC-25E10K0-D-74-SE 2500 80 2100 11291 10162 37.6 79.0 143 BXRC-27E10K0-B-7x-SE 2700 80 1800 14321 12889 52.0 93.6 153 BXRC-27E10K0-C-7x-SE 2700 80 1710 18157 16341 69.4 118.7 153 BXRC-27E10K0-D-7x-SE 2700 80 2100 12081 10873 37.6 79.0 153 BXRC-27G1KH0-B-7x-SE 2700 90 1800 12355 11120 52.0 93.6 132 BXRC-27G1KH0-C-7x-SE 2700 90 1710 15665 14098 69.4 118.7 132 BXRC-27G1KH0-D-7x-SE 2700 90 2100 10423 9380 37.6 79.0 132 BXRC-27G10K0-B-7x-SE 2700 90 1800 11887 10698 52.0 93.6 127 BXRC-27G10K0-C-7x-SE 2700 90 1710 15072 13564 69.4 118.7 127 BXRC-27G10K0-D-7x-SE 2700 90 2100 10028 9025 37.6 79.0 127 10 BXRC-27H10K0-D-74-SE 2700 97 2100 8765 7888 37.6 79.0 111 BXRC-30C10K1-B-74-SE 3000 70 1800 16380 14742 52.0 93.6 175 175 BXRC-30C10K1-C-74-SE 3000 70 1710 20768 18691 69.4 118.7 BXRC-30C10K1-D-74-SE 3000 70 2100 13818 12436 37.6 79.0 175 BXRC-30E10K0-B-7x-SE10 3000 80 1800 14882 13394 52.0 93.6 159 BXRC-30E10K0-C-7x-SE10 3000 80 1710 18869 16982 69.4 118.7 159 BXRC-30E10K0-D-7x-SE10 3000 80 2100 12555 11299 37.6 79.0 159 BXRC-30G1KH0-B-7x-SE 3000 90 1800 12917 11625 52.0 93.6 138 BXRC-30G1KH0-C-7x-SE 3000 90 1710 16377 14739 69.4 118.7 138 BXRC-30G1KH0-D-7x-SE 3000 90 2100 10896 9807 37.6 79.0 138 BXRC-30G10K0-B-7x-SE 3000 90 1800 12449 11204 52.0 93.6 133 BXRC-30G10K0-C-7x-SE 3000 90 1710 15784 14205 69.4 118.7 133 BXRC-30G10K0-D-7x-SE 3000 90 2100 10502 9452 37.6 79.0 133 BXRC-30H10K0-D-7X-SE 3000 97 2100 9317 8386 37.6 79.0 118 8,9 BXRC-30A10K1-B-73-SE 3000 93 1800 11232 10109 52.0 93.6 120 BXRC-30A10K1-C-73-SE8,9 3000 93 1710 14241 12817 69.4 118.7 120 BXRC-30A10K1-D-73-SE8,9 3000 93 2100 9475 8528 37.6 79.0 120 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI Nominal Drive Current3 (mA) 2 Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x-SE10 3500 80 1800 15350 13815 52.0 93.6 164 BXRC-35E10K0-C-7x-SE10 3500 80 1710 19463 17516 69.4 118.7 164 BXRC-35E10K0-D-7x-SE 3500 80 2100 12949 11654 37.6 79.0 164 BXRC-35G10K0-B-7x-SE 3500 90 1800 12823 11541 52.0 93.6 137 BXRC-35G10K0-C-7x-SE 3500 90 1710 16258 14633 69.4 118.7 137 BXRC-35G10K0-D-7x-SE 3500 90 2100 10818 9736 37.6 79.0 137 BXRC-35A10K1-B-73-SE8,9 3500 93 1800 12074 10867 52.0 93.6 129 129 10 BXRC-35A10K1-C-73-SE8,9 3500 93 1710 15309 13778 69.4 118.7 BXRC-35A10K1-D-73-SE8,9 3500 93 2100 10186 9167 37.6 79.0 129 BXRC-40C10K1-B-74-SE 4000 70 1800 16848 15163 52.0 93.6 180 BXRC-40C10K1-C-74-SE 4000 70 1710 21361 19225 69.4 118.7 180 BXRC-40C10K1-D-74-SE 4000 70 2100 14213 12792 37.6 79.0 180 BXRC-40E10K0-B-7x-SE10 4000 80 1800 15444 13900 52.0 93.6 165 BXRC-40E10K0-C-7x-SE10 4000 80 1710 19581 17623 69.4 118.7 165 BXRC-40E10K0-D-7x-SE 4000 80 2100 13028 11726 37.6 79.0 165 BXRC-40G10K0-B-7x-SE 4000 90 1800 13291 11962 52.0 93.6 142 BXRC-40G10K0-C-7x-SE 4000 90 1710 16852 15167 69.4 118.7 142 BXRC-40G10K0-D-7x-SE 4000 90 2100 11212 10091 37.6 79.0 142 BXRC-40H10K0-D-7X-SE 4000 97 2100 9633 8670 37.6 79.0 122 BXRC-40A10K1-B-73-SE8,9 4000 93 1800 12917 11625 52.0 93.6 138 BXRC-40A10K1-C-73-SE8,9 4000 93 1710 16377 14739 69.4 118.7 138 10 8,9 BXRC-40A10K1-D-73-SE 4000 93 2100 10896 9807 37.6 79.0 138 BXRC-50C10K1-B-7x-SE10 5000 70 1800 17035 15332 52.0 93.6 182 BXRC-50C10K1-C-7x-SE10 5000 70 1710 21599 19439 69.4 118.7 182 BXRC-50C10K1-D-7x-SE10 5000 70 2100 14371 12934 37.6 79.0 182 BXRC-50E10K1-B-7x-SE10 5000 80 1800 16006 14405 52.0 93.6 171 BXRC-50E10K1-C-7x-SE10 5000 80 1710 20293 18264 69.4 118.7 171 BXRC-50E10K1-D-7x-SE10 5000 80 2100 13502 12152 37.6 79.0 171 BXRC-50G10K1-B-7x-SE 5000 90 1800 13572 12215 52.0 93.6 145 BXRC-50G10K1-C-74-SE 5000 90 1710 17208 15487 69.4 118.7 145 BXRC-50G10K1-D-74-SE 5000 90 2100 11449 10304 37.6 79.0 145 BXRC-56G10K0-B-74-SE 5600 80 1800 14227 12804 52.0 93.6 152 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-50G10K1-C-7x-SE 5600 80 1710 18038 16235 69.4 118.7 152 BXRC-50G10K1-D-7x-SE 5600 80 2100 12002 10802 37.6 79.0 152 BXRC-56G10K1-B-74-SE 5600 97 2100 10423 9380 37.6 79.0 132 BXRC-56G10K1-C-74-SE 5700 70 1800 16474 14826 52.0 93.6 176 BXRC-56G10Kx-D-74-SE 5700 70 1710 20887 18798 69.4 118.7 176 BXRC-56H10K0-D-74-SE 5700 70 2100 13897 12507 37.6 79.0 176 10 BXRC-57C10K1-B-7x-SE 5700 80 1800 15818 14237 52.0 93.6 169 BXRC-57C10K1-C-7x-SE10 5700 80 1710 20056 18050 69.4 118.7 169 BXRC-57C10K1-D-7x-SE10 5700 80 2100 13344 12010 37.6 79.0 169 BXRC-57E10K1-B-7x-SE10 6500 70 1800 16754 15079 52.0 93.6 179 BXRC-57E10K1-C-7x-SE10 6500 70 1710 21243 19118 69.4 118.7 179 BXRC-57E10K1-D-7x-SE10 6500 70 2100 14134 12720 37.6 79.0 179 BXRC-65C10K1-B-7x-SE10 6500 80 1800 16099 14489 52.0 93.6 172 10 BXRC-65C10K1-C-7x-SE 6500 80 1710 20412 18371 69.4 118.7 172 BXRC-65C10K1-D-7x-SE10 6500 80 2100 13581 12223 37.6 79.0 172 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 10. SKUs meet DLC premium (Outdoor Mid Output) requirements under certain system level conditions. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A10K1-B-73-SE 3000 80 93 1800 10446 9401 50.9 91.6 114 BXRC-30A10K1-C-73-SE 3000 80 93 1710 13244 11920 67.9 116.1 114 BXRC-30A10K1-D-73-SE 3000 80 93 2100 8812 7931 36.8 77.3 114 BXRC-35A10K1-B-73-SE 3500 80 93 1800 11229 10106 50.9 91.6 123 BXRC-35A10K1-C-73-SE 3500 80 93 1710 14237 12814 67.9 116.1 123 BXRC-35A10K1-D-73-SE 3500 80 93 2100 9473 8526 36.8 77.3 123 BXRC-40A10K1-B-73-SE 4000 80 93 1800 12013 10811 50.9 91.6 131 BXRC-40A10K1-C-73-SE 4000 80 93 1710 15231 13708 67.9 116.1 131 BXRC-40A10K1-D-73-SE 4000 80 93 2100 10134 9120 36.8 77.3 131 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-17E10K0-B-74-SE 1750 80 1800 7413 6672 50.7 91.2 81 BXRC-17E10K0-C-74-SE 1750 80 1710 9399 8459 68.1 116.4 81 BXRC-17E10K0-D-74-SE 1750 80 2100 6254 5628 36.6 76.8 81 BXRC-20B10K1-C-73-SE 2000 65 1710 15914 14323 68.1 116.4 137 BXRC-20B10K1-D-73-SE 2000 65 2100 10589 9530 36.6 76.8 138 132 BXRC-25E10K0-B-74-SE 2500 80 1800 12046 10842 50.7 91.2 BXRC-25E10K0-C-74-SE 2500 80 1710 15273 13746 68.1 116.4 131 BXRC-25E10K0-D-74-SE 2500 80 2100 10162 9146 36.6 76.8 132 BXRC-27E10K0-B-7x-SE 2700 80 1800 12889 11600 50.7 91.2 141 BXRC-27E10K0-C-7x-SE 2700 80 1710 16341 14707 68.1 116.4 140 BXRC-27E10K0-D-7x-SE 2700 80 2100 10873 9786 36.6 76.8 142 122 BXRC-27G1KH0-B-7x-SE 2700 90 1800 11120 10008 50.7 91.2 BXRC-27G1KH0-C-7x-SE 2700 90 1710 14098 12689 68.1 116.4 121 BXRC-27G1KH0-D-7x-SE 2700 90 2100 9380 8442 36.6 76.8 122 117 BXRC-27G10K0-B-7x-SE 2700 90 1800 10698 9629 50.7 91.2 BXRC-27G10K0-C-7x-SE 2700 90 1710 13564 12208 68.1 116.4 117 BXRC-27G10K0-D-7x-SE 2700 90 2100 9025 8123 36.6 76.8 118 BXRC-27H10K0-D-74-SE 2700 97 2100 7888 7099 36.6 76.9 103 162 BXRC-30C10K1-B-74-SE 3000 70 1800 14742 13268 50.7 91.2 BXRC-30C10K1-C-74-SE 3000 70 1710 18691 16822 68.1 116.4 161 BXRC-30C10K1-D-74-SE 3000 70 2100 12436 11193 36.6 76.8 162 BXRC-30E10K0-B-7x-SE 3000 80 1800 13394 12055 50.7 91.2 147 BXRC-30E10K0-C-7x-SE 3000 80 1710 16982 15284 68.1 116.4 146 BXRC-30E10K0-D-7x-SE 3000 80 2100 11299 10169 36.6 76.8 147 BXRC-30G1KH0-B-7X-SE 3000 90 1800 11625 10463 50.7 91.2 127 BXRC-30G1KH0-C-7X-SE 3000 90 1710 14739 13265 68.1 116.4 127 BXRC-30G1KH0-D-7X-SE 3000 90 2100 9807 8826 36.6 76.8 128 123 BXRC-30G10K0-B-7x-SE 3000 90 1800 11204 10084 50.7 91.2 BXRC-30G10K0-C-7x-SE 3000 90 1710 14205 12785 68.1 116.4 122 BXRC-30G10K0-D-7x-SE 3000 90 2100 9452 8506 36.6 76.8 123 BXRC-30H10K0-D-7X-SE 3000 97 2100 8386 7547 36.6 76.8 109 7,8 BXRC-30A10K1-B-73-SE 3000 93 1800 10109 9098 50.7 91.2 111 BXRC-30A10K1-C-73-SE7,8 3000 93 1710 12817 11535 68.1 116.4 110 BXRC-30A10K1-D-73-SE7,8 3000 93 2100 8528 7675 36.6 76.8 111 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E10K0-B-7x-SE 3500 80 1800 13815 12434 50.7 91.2 151 BXRC-35E10K0-C-7x-SE 3500 80 1710 17516 15765 68.1 116.4 150 BXRC-35E10K0-D-7x-SE 3500 80 2100 11654 10489 36.6 76.8 152 BXRC-35G10K0-B-7x-SE 3500 90 1800 11541 10387 50.7 91.2 127 BXRC-35G10K0-C-7x-SE 3500 90 1710 14633 13169 68.1 116.4 126 127 BXRC-35G10K0-D-7x-SE 3500 90 2100 9736 8762 36.6 76.8 BXRC-35A10K1-B-73-SE7,8 3500 93 1800 10867 9780 50.7 91.2 119 BXRC-35A10K1-C-73-SE7,8 3500 93 1710 13778 12400 68.1 116.4 118 BXRC-35A10K1-D-73-SE7,8 3500 93 2100 9167 8251 36.6 76.8 119 BXRC-40C10K1-B-74-SE 4000 70 1800 15163 13647 50.7 91.2 166 BXRC-40C10K1-C-74-SE 4000 70 1710 19225 17303 68.1 116.4 165 BXRC-40C10K1-D-74-SE 4000 70 2100 12792 11512 36.6 76.8 167 BXRC-40E10K0-B-7x-SE 4000 80 1800 13900 12510 50.7 91.2 152 BXRC-40E10K0-C-7x-SE 4000 80 1710 17623 15861 68.1 116.4 151 153 BXRC-40E10K0-D-7x-SE 4000 80 2100 11726 10553 36.6 76.8 BXRC-40G10K0-B-7x-SE 4000 90 1800 11962 10766 50.7 91.2 131 BXRC-40G10K0-C-7x-SE 4000 90 1710 15167 13650 68.1 116.4 130 BXRC-40G10K0-D-7x-SE 4000 90 2100 10091 9082 36.6 76.8 131 BXRC-40H10K0-D-7X-SE 4000 97 2100 8670 7803 36.6 76.8 113 7,8 BXRC-40A10K1-B-73-SE 4000 93 1800 11625 10463 50.7 91.2 127 BXRC-40A10K1-C-73-SE7,8 4000 93 1710 14739 13265 68.1 116.4 127 BXRC-40A10K1-D-73-SE7,8 4000 93 2100 9807 8826 36.6 76.8 128 168 BXRC-50C10K1-B-7x-SE 5000 70 1800 15332 13799 50.7 91.2 BXRC-50C10K1-C-7x-SE 5000 70 1710 19439 17495 68.1 116.4 167 BXRC-50C10K1-D-7x-SE 5000 70 2100 12934 11640 36.6 76.8 168 158 BXRC-50E10K1-B-7x-SE 5000 80 1800 14405 12965 50.7 91.2 BXRC-50E10K1-C-7x-SE 5000 80 1710 18264 16438 68.1 116.4 157 BXRC-50E10K1-D-7x-SE 5000 80 2100 12152 10937 36.6 76.8 158 BXRC-50G10K1-B-7x-SE 5000 90 1800 12215 10993 50.7 91.2 134 BXRC-50G10K1-C-7x-SE 5000 90 1710 15487 13938 68.1 116.4 133 BXRC-50G10K1-D-7x-SE 5000 90 2100 10304 9274 36.6 76.8 134 BXRC-56G10K1-B-74-SE 5600 80 1800 12804 11524 50.7 91.2 140 139 BXRC-56G10K1-C-74-SE 5600 80 1710 16235 14611 68.1 116.4 BXRC-56G10Kx-D-74-SE 5600 80 2100 10802 9722 36.6 76.8 141 BXRC-56H10K0-D-74-SE 5600 97 2100 9380 8442 36.6 76.8 122 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 163 BXRC-57C10K1-B-7x-SE 5700 70 1800 14826 13344 50.7 91.2 BXRC-57C10K1-C-7x-SE 5700 70 1710 18798 16918 68.1 116.4 161 BXRC-57C10K1-D-7x-SE 5700 70 2100 12507 11257 36.6 76.8 163 BXRC-57E10K1-B-7x-SE 5700 80 1800 14237 12813 50.7 91.2 156 BXRC-57E10K1-C-7x-SE 5700 80 1710 18050 16245 68.1 116.4 155 BXRC-57E10K1-D-7x-SE 5700 80 2100 12010 10809 36.6 76.8 156 BXRC-65C10K1-B-7x-SE 6500 70 1800 15079 13571 50.7 91.2 165 BXRC-65C10K1-C-7x-SE 6500 70 1710 19118 17207 68.1 116.4 164 BXRC-65C10K1-D-7x-SE 6500 70 2100 12720 11448 36.6 76.8 166 BXRC-65E10K1-B-7x-SE 6500 80 1800 14489 13040 50.7 91.2 159 BXRC-65E10K1-C-7x-SE 6500 80 1710 18371 16534 68.1 116.4 158 BXRC-65E10K1-D-7x-SE 6500 80 2100 12223 11001 36.6 76.8 159 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero SE LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero SE may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-17E10K0-B-74-SE 80 BXRC-17E10K0-C-74-SE 80 BXRC-17E10K0-D-74-SE 80 BXRC-20B10K1-C-73-SE 65 BXRC-20B10K1-D-73-SE 65 BXRC-25E10K0-B-74-SE 80 BXRC-25E10K0-C-74-SE 80 BXRC-25E10K0-D-74-SE 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 4276 5630 8237 11873 15196 5933 7540 10443 14815 18569 3822 4919 6948 9892 12468 10045 12767 17682 25085 31441 6471 8328 11765 16749 21110 6948 9149 13385 19294 24694 9640 12253 16970 24075 30175 6211 7993 11291 16075 20260 3903 5118 7413 10589 13389 5645 6955 9399 12742 15603 3724 4578 6254 8335 10181 9559 11777 15914 21575 26419 6305 7751 10589 14113 17238 6343 8317 12046 17207 21757 9174 11302 15273 20706 25356 6052 7439 10162 13544 16544 96 93 88 81 76 105 98 88 80 73 103 97 88 80 72 178 166 149 136 124 174 164 149 135 122 156 151 143 132 123 170 160 143 130 119 167 158 143 129 117 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27E10K0-B-7x-SE 80 BXRC-27E10K0-C-7x-SE 80 BXRC-27E10K0-D-7x-SE 80 BXRC-27G1KH0-B-7x-SE 90 BXRC-27G1KH0-C-7x-SE 90 BXRC-27G1KH0-D-7x-SE 90 BXRC-27G10K0-B-7x-SE 90 BXRC-27G10K0-C-7x-SE 90 BXRC-27G10K0-D-7x-SE 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 7434 9789 14321 20643 26421 10315 13110 18157 25758 32285 6645 8552 12081 17199 21677 6414 8445 12355 17810 22795 8899 11310 15665 22223 27854 5733 7378 10423 14838 18701 6171 8125 11887 17135 21931 8562 10882 15072 21381 26799 5516 7099 10028 14276 17993 6786 8898 12889 18410 23279 9815 12093 16341 22154 27129 6475 7959 10873 14492 17701 5855 7677 11120 15883 20084 8468 10433 14098 19113 23405 5586 6866 9380 12503 15271 5633 7386 10698 15281 19323 8147 10038 13564 18389 22519 5374 6606 9025 12029 14693 166 162 153 141 131 182 171 153 139 127 179 169 153 138 125 144 139 132 122 113 157 147 132 120 109 154 146 132 119 108 138 134 127 117 109 151 142 127 116 105 148 140 127 115 104 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27H10K0-D-74-SE 97 BXRC-30C10K1-B-74-SE 70 BXRC-30C10K1-C-74-SE 70 BXRC-30C10K1-D-74-SE 70 BXRC-30E10K0-B-7x-SE 80 BXRC-30E10K0-C-7x-SE 80 BXRC-30E10K0-D-7x-SE 80 BXRC-30G1KH0-B-7x-SE 90 BXRC-30G1KH0-C-7x-SE 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 4821 6204 8765 12478 15726 9305 11827 16380 23237 29125 11423 14702 20768 29566 37264 7601 9782 13818 19672 24794 7726 10173 14882 21453 27457 10719 13624 18869 26768 33551 6906 8887 12555 17873 22527 6705 8829 12917 18619 23831 9303 11824 16377 23233 29120 4697 5774 7888 10514 12842 8855 10909 14742 19986 24473 11131 13682 18691 24912 30429 7406 9103 12436 16575 20246 7052 9247 13394 19132 24192 10200 12567 16982 23023 28193 6729 8271 11299 15060 18395 6121 8026 11625 16605 20997 8853 10907 14739 19982 24469 130 123 111 100 91 208 195 175 159 145 202 192 175 160 146 204 193 175 158 143 173 168 159 147 137 189 178 159 145 132 186 176 159 144 130 150 146 138 127 119 164 154 138 126 114 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G1KH0-D-7x-SE 90 BXRC-30G10K0-B-7x-SE 90 BXRC-30G10K0-C-7x-SE 90 BXRC-30G10K0-D-7x-SE 90 BXRC-30H10K0-D-7x-SE 97 BXRC-30A10K1-B-73-SE 93 BXRC-30A10K1-C-73-SE 93 BXRC-30A10K1-D-73-SE 93 BXRC-35E10K0-B-7x-SE 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 5994 7714 10896 15513 19552 6462 8509 12449 17945 22967 8966 11396 15784 22391 28065 5776 7434 10502 14951 18843 5125 6596 9317 13265 16718 5831 7678 11232 16191 20722 8090 10282 14241 20202 25322 5212 6707 9475 13489 17001 7969 10493 15350 22127 28321 5840 7179 9807 13071 15966 5899 7735 11204 16003 20236 8532 10512 14205 19258 23582 5628 6919 9452 12597 15387 4994 6138 8386 11177 13652 5322 6979 10109 14439 18258 7698 9485 12817 17376 21277 5078 6242 8528 11366 13883 7274 9538 13815 19734 24952 161 152 138 125 113 145 141 133 123 114 158 149 133 121 110 155 147 133 120 109 138 130 118 107 97 131 127 120 111 103 143 134 120 109 99 140 132 120 108 98 178 173 164 151 141 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35E10K0-C-7x-SE 80 BXRC-35E10K0-D-7x-SE 80 BXRC-35G10K0-B-7x-SE 90 BXRC-35G10K0-C-7x-SE 90 BXRC-35G10K0-D-7x-SE 90 BXRC-35A10K1-B-73-SE 93 BXRC-35A10K1-C-73-SE 93 BXRC-35A10K1-D-73-SE 93 BXRC-40C10K1-B-74-SE 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 11056 14052 19463 27610 34606 7123 9167 12949 18435 23235 6657 8765 12823 18484 23658 9236 11739 16258 23064 28909 5950 7658 10818 15400 19410 6268 8253 12074 17405 22277 8697 11053 15309 21718 27221 5603 7211 10186 14501 18276 8746 11516 16848 24286 31084 10521 12962 17516 23747 29079 6940 8531 11654 15534 18974 6076 7968 11541 16485 20844 8789 10828 14633 19837 24292 5798 7127 9736 12976 15850 5722 7502 10867 15522 19627 8276 10196 13778 18679 22873 5459 6710 9167 12218 14924 7984 10468 15163 21659 27387 195 183 164 149 136 191 181 164 148 134 149 145 137 127 118 163 153 137 125 114 160 151 137 124 112 140 136 129 119 111 154 144 129 117 107 151 142 129 117 106 196 190 180 166 155 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C10K1-C-74-SE 70 BXRC-40C10K1-D-74-SE 70 BXRC-40E10K0-B-7x-SE 80 BXRC-40E10K0-C-7x-SE 80 BXRC-40E10K0-D-7x-SE 80 BXRC-40G10K0-B-7x-SE 90 BXRC-40G10K0-C-7x-SE 90 BXRC-40G10K0-D-7x-SE 90 BXRC-40H10K0-D-7x-SE 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 12135 15423 21361 30304 37983 7818 10061 14213 20234 25502 8017 10557 15444 22262 28493 11123 14138 19581 27778 34818 7166 9223 13028 18548 23377 6900 9085 13291 19159 24521 9573 12167 16852 23906 29964 6167 7937 11212 15962 20118 5299 6819 9633 13714 17285 11547 14227 19225 26063 31916 7617 9363 12792 17049 20825 7318 9596 13900 19854 25105 10585 13041 17623 23891 29256 6983 8583 11726 15628 19089 6298 8258 11962 17086 21605 9110 11223 15167 20561 25178 6009 7387 10091 13450 16428 5163 6346 8670 11555 14114 214 201 180 164 149 210 199 180 163 147 179 174 165 152 142 197 184 165 150 137 193 182 165 149 135 154 150 142 131 122 169 159 142 129 118 166 157 142 128 116 142 135 122 110 100 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40A10K1-B-73-SE 93 BXRC-40A10K1-C-73-SE 93 BXRC-40A10K1-D-73-SE 93 BXRC-50C10K1-B-74-SE 70 BXRC-50C10K1-C-74-SE 70 BXRC-50C10K1-D-74-SE 70 BXRC-50E10K1-B-74-SE 80 BXRC-50E10K1-C-74-SE 80 BXRC-50E10K1-D-74-SE 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 6705 8829 12917 18619 23831 9303 11824 16377 23233 29120 5994 7714 10896 15513 19552 8843 11644 17035 24556 31429 12270 15594 21599 30640 38405 7905 10173 14371 20459 25785 8309 10940 16006 23072 29529 11528 14652 20293 28788 36084 7427 9558 13502 19222 24227 6121 8026 11625 16605 20997 8853 10907 14739 19982 24469 5840 7179 9807 13071 15966 8072 10585 15332 21899 27691 11676 14385 19439 26353 32271 7702 9467 12934 17238 21056 7585 9945 14405 20576 26018 10970 13516 18264 24760 30320 7236 8895 12152 16197 19783 150 146 138 127 119 164 154 138 126 114 161 152 138 125 113 198 192 182 168 156 217 203 182 166 151 212 201 182 165 149 186 181 171 158 147 204 191 171 156 142 200 189 171 155 140 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50G10K1-B-74-SE 90 BXRC-50G10K1-C-74-SE 90 BXRC-50G10K1-D-74-SE 90 BXRC-56G10K0-B-74-SE 80 BXRC-56G10K0-C-74-SE 80 BXRC-56G10K0-D-74-SE 80 BXRC-56H10K0-D-74-SE 80 BXRC-57C10K1-B-74-SE 70 BXRC-57C10K1-C-74-SE 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7046 9277 13572 19564 25040 9775 12424 17208 24411 30597 6298 8105 11449 16300 20543 7386 9725 14227 20508 26248 10247 13024 18038 25590 32074 6602 8496 12002 17087 21535 5733 7378 10423 14838 18701 8552 11260 16474 23746 30393 11865 15080 20887 29630 37139 6431 8433 12215 17447 22062 9302 11461 15487 20996 25710 6136 7543 10304 13734 16775 6742 8840 12804 18290 23127 9751 12014 16235 22009 26951 6432 7907 10802 14397 17585 5586 6866 9380 12503 15271 7806 10236 14826 21177 26778 11291 13911 18798 25484 31207 158 153 145 134 125 173 162 145 132 120 169 160 145 131 119 165 161 152 140 131 181 170 152 138 126 177 168 152 137 125 154 146 132 119 108 191 186 176 163 151 210 197 176 160 146 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57C10K1-D-74-SE 70 BXRC-57E10K1-B-74-SE 80 BXRC-57E10K1-C-74-SE 80 BXRC-57E10K1-D-74-SE 80 BXRC-65C10K1-B-74-SE 70 BXRC-65C10K1-C-74-SE 70 BXRC-65C10K1-D-74-SE 70 BXRC-65E10K1-B-74-SE 80 BXRC-65E10K1-C-7x-SE 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 1050 1400 2100 3150 4200 900 1200 1800 2700 3600 855 1140 1710 2565 3420 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 35.4 36.2 37.6 39.5 41.2 49.6 50.5 52.0 54.1 55.8 66.2 67.3 69.4 72.1 74.4 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 37.2 50.6 79.0 124.4 172.9 44.7 60.6 93.6 146.1 201.0 56.6 76.7 118.7 185.0 254.6 7644 9838 13897 19784 24935 8212 10812 15818 22802 29184 11393 14481 20056 28452 35662 7340 9446 13344 18998 23944 8698 11452 16754 24151 30911 12067 15337 21243 30135 37772 7774 10005 14134 20122 25360 8357 11004 16099 23207 29702 11595 14738 20412 28957 36295 7448 9155 12507 16670 20362 7496 9829 14237 20335 25713 10842 13357 18050 24471 29966 7152 8791 12010 16007 19552 7939 10410 15079 21538 27235 11483 14148 19118 25919 31739 7575 9311 12720 16954 20709 7629 10003 14489 20696 26170 11034 13595 18371 24905 30498 205 194 176 159 144 184 179 169 156 145 201 189 169 154 140 197 187 169 153 138 195 189 179 165 154 213 200 179 163 148 209 198 179 162 147 187 182 172 159 148 205 192 172 157 143 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number BXRC-65E10K1-D-7x-SE CRI Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 80 1050 1400 2100 3150 4200 35.4 36.2 37.6 39.5 41.2 37.2 50.6 79.0 124.4 172.9 7470 9614 13581 19335 24369 7279 8947 12223 16291 19899 201 190 172 155 141 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 19 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx10Kx-B-7x-SE BXRC-xxx10Kx-C-7x-SE BXRC-xxx10Kx-D-7x-SE Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.06 46.1 57.5 -24.9 0.07 49.7 61.6 74.6 -33.2 0.04 61.5 76.8 74.4 80.0 -33.2 0.05 66.2 82.2 34.8 37.6 40.4 -17.4 0.06 33.4 41.6 38.1 41.2 44.3 -17.4 0.07 36.7 45.4 Minimum Typical Maximum 1800 48.1 52.0 55.9 -24.9 3600 51.7 55.8 60.0 1710 64.2 69.4 3420 68.8 2100 4200 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 20 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx10Kx-B-7x-SE BXRC-xxx10Kx-C-7x-SE BXRC-xxx10Kx-D-7x-SE CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 1800 RG1 RG1 RG1 RG1 2700 RG1 RG1 RG2 RG2 3600 RG1 RG1 RG2 RG2 1710 RG1 RG1 RG1 RG2 2565 RG1 RG1 RG2 RG2 3420 RG1 RG2 RG2 RG2 2100 RG1 RG1 RG1 RG1 3150 RG1 RG1 RG1 RG2 4200 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero SE Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 21 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C BXRC-xxx10Kx-B-7x-SE BXRC-xxx10Kx-C-7x-SE BXRC-xxx10Kx-D-7x-SE Maximum Drive Current3 3600mA 3420mA 4200mA Maximum Peak Pulsed Drive Current4 5140mA 4890mA 6000mA Maximum Reverse Voltage5 -90V -120V -65V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN120: Assembly Considerations for Bridgelux Vero SE LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 22 Performance Curves Figure 2: Vero SE 29C Drive Current vs. Voltage 4000 4000 3500 3500 3000 3000 Forward Current (mA) Forward Current (mA) Figure 1: Vero SE 29B Drive Current vs. Voltage 2500 2000 1500 1000 2500 2000 1500 1000 500 0 500 47 48 49 50 51 52 53 54 55 56 57 0 58 63 64 65 66 67 68 Forward Voltage (V) Figure 3: Vero SE 29D Drive Current vs. Voltage 71 72 73 74 75 76 200% 180% 4000 160% Relative Luminous Flux 3500 Forward Current (mA) 70 Figure 4: Vero SE 29B Typical Relative Flux vs. Current 4500 3000 2500 2000 1500 1000 140% 120% 100% 80% 60% 40% 500 0 69 Forward Voltage (V) 20% 33 34 35 36 37 38 39 40 41 42 0% 0 Forward Voltage (V) 500 1000 1500 2000 2500 3000 3500 4000 Forward Current (mA) Figure 6 Vero SE 29D Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux Figure 5: Vero SE 29C Typical Relative Flux vs. Current 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0 400 800 1200 1600 2000 2400 Forward Current (mA) 2800 3200 3600 4000 0% 0 500 1000 1500 2000 2500 3000 3500 4000 4500 Forward Current (mA) Notes for Figures 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 23 Performance Curves Figure 7: Typical DC Flux vs. Case Temperature Figure 8: Typical DC ccy Shift vs. Case Temperature 0 103% Neutral White 50 75 100 125 0.000 Cool White 25°C Pulsed 97% -0.003 ccy Shift Relative Luminous Flux 100% 25 0.003 Warm White 94% 91% -0.006 -0.009 88% Warm White -0.012 85% -0.015 82% 0 25 50 75 100 Neutral White Cool White 25°C Pulsed 125 Case Temperature (°C) Case Temperature (°C) Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: Typical DC ccx Shift vs. Case Temperature 0.4101 0 25 50 75 100 0.41 125 0.4099 0.000 0.4098 -0.002 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 ccy ccx Shift -0.004 -0.006 65°C 0.4093 Warm White -0.012 0.4095 0.4094 -0.008 -0.010 45°C 0.4096 Neutral White 85°C 0.4092 Cool White 25°C Pulsed 105°C 0.4091 Case Temperature (°C) 0.409 0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532 ccx Notes for Figures 7-9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. . For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 24 Performance Curves Figure 11: 1750K Color Shift vs. Case Temperature1 Figure 12: 2500K Color Shift vs. Case Temperature1 0.3705 0.4145 Pulsed Center Point Tc = 25°C 15°C 0.37 15°C 0.414 25°C 0.413 0.3695 0.369 ccy ccy 45°C 85°C 0.411 105°C 0.52 70°C 85°C 0.4115 0.3685 0.5198 45°C 0.4125 0.412 70°C 0.368 0.5196 0.5202 0.5204 105°C 0.4105 0.468 0.5206 0.47 0.472 Figure 13: 5600K Color Shift vs. Case Temperature1,3 0.369 0.342 25°C 0.338 25°C 0.367 0.366 0.336 45°C 0.334 ccy ccy 15°C 0.368 Pulsed Center Point Tc = 25°C 15°C 0.34 0.332 70°C 0.478 Pulsed Center Point Tc=25°C 45°C 0.365 0.364 70°C 0.363 85°C 0.328 0.476 Figure 14: 3000K Class A Color Shift vs. Case Temperature1 0.344 0.326 0.474 ccx ccx 0.33 Pulsed Center Point Tc = 25°C 0.4135 25°C 85°C 0.362 105°C 0.361 0.324 0.322 0.32 0.322 0.324 0.326 0.328 105°C 0.36 0.416 0.33 0.4165 0.417 ccx Figure 15: 3500K Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 16: 4000K Class A Color Shift vs. Case Temperature1 0.37 0.3760 15°C 0.368 Pulsed Center Point Tc=25°C 25°C 0.366 15°C 0.3740 25°C 0.3720 45°C 45°C ccy 0.3700 ccy Pulsed Center Point Tc=25°C 0.364 0.3680 70°C 0.362 85°C 0.36 85°C 0.3640 105°C 0.358 0.392 70°C 0.3660 105°C 0.393 0.394 0.395 0.396 0.397 ccx 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 Note for Figures 10-16: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Color shift shown for product hot targeted at Tc=85°C 25 Performance Curves Figure 17: Vero SE 29D Drive Current Derating Curve 4400 Drive Current (mA) 4200 4000 3960 3800 3600 3400 Max Drive Current LM-80 Max Drive Current 3200 0 10 20 30 40 50 60 70 80 90 100 110 Case Temperature (⁰C) Notes for Figure 17: 1. The maximum allowable drive current for the Vero 29D product is dependent on the operating case temperature. Please refer to the Product Feature Map (page 2) for the location of the Tc Point 2. LM-80 Max Drive Current must not be exceeded in order to meet LM-80 lifetime projections. 3. Lumen maintenance (L70) and lifetime predictions are valid for drive current and case temperature conditions used for LM-80 testing as included in the applicable LM-80 test report for these products. Contact your Bridgelux sales representative for LM-80 report. 26 Typical Radiation Pattern Figure 18: Typical Spatial Radiation Pattern Note for Figure 18: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 19: Typical Polar Radiation Pattern 27 Typical Color Spectrum Figure 20: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 20: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 21: Typical Color Spectrum for Vero SE 29 with Décor Series 1 17E 20B 0.9 25E 27H Relative Spectral Power Distribution 0.8 30H 56G 0.7 56H 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 21: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 28 Mechanical Dimensions Figure 22: Drawing for Vero SE 29 LED Array Notes for Figure 22: 1. Drawings are not to scale. 2. Drawing dimensions are in millimeters. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting holes (2X) are for M3 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 43.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 8. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 29 Color Binning Information Figure 23: Graph of Warm and Neutral White Test Bins in xy Color Space 0.44 2500K 4SDCM 3 SDCM 4 SDCM 2000K 3SDCM 2700K 0.42 3000K 3500K 0.4 Y 4000K 1750K 4SDCM 0.38 0.36 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 1750K 2500K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5167, 0.336) (0.4765, 0.4137) (0.4578, 0.4101) (0.4338, 0.403) (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Class A products. Please contact your Bridgelux Sales Representative for more information. Figure 24: Graph of Cool White Test Bins in xy Color Space 0.39 4 SDCM 3 SDCM 0.38 0.37 5000K 0.36 5700K Y 0.35 0.34 6500K 0.33 0.32 0.31 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5600K1 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5829K - 5481K) (6270K - 6765K) 73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K) Center Point (x,y) (0.3447, 0.3553) (0.3293, 0.3423) (0.3287, 0.3417) (0.3123, 0.3282) Note for Table 9: 1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C. 30 Packaging and Labeling Figure 25: Drawing for Vero SE 29 Packaging Tray Notes for Figure 25: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 31 Packaging and Labeling Figure 26: Vero SE Series Packaging and Labeling Notes for Figure 26: 1. Each tray holds 50 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 27: Vero SE Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E10K0C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin definitions. 32 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN120 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 33 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Vero SE 29 Array Series Product Data Sheet DS123 Rev. K (11/2018) 34
BXRC-40E10K0-C-73-SE 价格&库存

很抱歉,暂时无法提供与“BXRC-40E10K0-C-73-SE”相匹配的价格&库存,您可以联系我们找货

免费人工找货