Counters and Ratemeters
Counting accuracy
www.crouzet-control.com
Presentation
Crouzet Control
Expert in the design of efficient and innovative monitoring & control products, Crouzet Control,
supported by an experienced worldwide team, offers a broad range of industry standard and
application specific adapted products in timing, control relays and counting functions.
Crouzet Control is a brand of InnoVista Sensors™.
With operations around the globe, Crouzet Control is constantly monitoring its customers' needs.
Its sales teams, technicians and designers combine all their skills to adapt products to customer
specifications, both in terms of the application and cost.
Crouzet Control also ensures that its products are manufactured in compliance with quality and
environmental standards (factories certified ISO 9001, 14001 and OHSAS 18001, eco-design).
With its industrial and logistic flexibility Crouzet Control is able to deliver products, whether smallscale or mass production items, in the best possible timescale.
Within this counter catalogue,
Crouzet Control presents:
Over
120 recently launched ergonomic counters for better equipment integration including
small formats..
New electromechanical range:
• Dual function hour counter and energy meter
• Dual function hour and impulse counter displays
New electronic range:
• Counters with backlit double LCD or two colour display
• Multi-function Counters
• Counters that integrate a Tachometer function
In addition to this catalogue, the www.crouzet-control.com
website offers the latest tools, available as free downloads,
including M3 Soft software, technical data sheets for each
product and installation manuals.
2
www.crouzet-control.com
InnoVista Sensors™
your trusted partner of choice to
face industrial challenges of today
and tomorrow
InnoVista Sensors™ is a worldwide industrial specialist of sensors, controllers and actuators for
automated systems.
Through its brands, Crouzet Aerospace, Crouzet Automation, Crouzet Control, Crouzet Motors,
Crouzet Switches and Systron Donner Inertial, InnoVista Sensors™ offers a wide range of reliable,
efficient and customizable components dedicated to the Aerospace & Defence, Transportation
and Industrial market and segments.
Thanks to the recognized expertise of its teams and a strong innovation policy, InnoVista Sensors™
brings performance enhancing solutions to its customers worldwide.
The Crouzet Control team worldwide
Production
Sales subsidiaries
www.crouzet-control.com
3
The basics
A counter, a ratemeter
How can they be defined in simple
terms?
A counter can be used to count a number of actions or events.
It thus participates in production management and preventive maintenance.
A ratemeter can be used to display the speed of rotation of a motor in real time.
A counter, a ratemeter
To execute which actions?
Up counting, Down counting
Up counting
For up counting or down counting a number of parts, events, a
running time, the counter is the ideal solution. There are different
types of counter with the following functions: up/down counter, batch
counter, ratemeter, chronometer, multi-totalizer, elapsed time counter,
impulse counter.
Down counting
Informing, Displaying
Informing
A counter can allow a user to be informed and to display data and
quantities easily. The data displayed can be read directly on the front
panel.
Displaying
Tripping, Actuating
A counter can be used to trip an action or an intervention on a
machine. The outputs actuate directly and/or transmit data to the
control system.
Measuring, Chronometer timing
A counter can be used to schedule preventive maintenance. The
machine running time is measured and the duration of an action
timed with a chronometer.
Tripping
Actuating Measuring
Chronometer timing
In addition to this catalogue, the www.crouzet-control.com
website offers technical data sheets for each product and
installation manuals, available as free downloads.
4
www.crouzet-control.com
Crouzet Control counters and ratemeters
A digital range and
an electromechanical range
Operating
time
Power
used
Preset
settings
Enable
Mode
CTR48
CEM48
Counters
and
Ratemeters
Crouzet Control counters and ratemeters
Their features:
• For fast count applications, a high-speed
counting frequency: up to 50 kHz.
• A two-colour or backlit LCD dual display
for ease of reading.
• Considerable space saving due to dualfunction electromechanical and electronic
ranges.
www.crouzet-control.com
• A complete output operating logic to cover
complex applications.
• Easier maintenance thanks to removable
connectors (CTR48).
• An enhanced multifunction electronic range
for optimised stocks.
5
Applications
Crouzet Control counters and ratemeters
Where are they found?
In electrical cabinets associated with other automation functions for the following markets:
• Industrial automation systems
• Building equipment
Tachometer systems
Speed measurement and control
on shrink wrapping machine.
ELECTRONIC COUNTER
CTR24L 2511
Metric counting
Calculation of cut length on
wood and paper machines.
ELECTRONIC COUNTER
CTR48
6
• Industrial machines
• Medical
Counting quantities
Managing quantities Packaging by unit, batch or
series of batches.
ELECTRONIC COUNTER
CTR48
Position control
Managing quantities Calculation of distance
of travel.
ELECTRONIC COUNTER
CTR48
www.crouzet-control.com
Compressors
Counting operating hours
and counting the number
of starts.
ELECTROMECHANICAL
HOUR AND IMPULSE
COUNTER
CMM48
Assembly line speed
Control of conveyor
movement speed.
RATEMETER
CTR24L 2511
Lifts
Combined impulse and hour
counters - Maintenance.
Start counters and
operating time counters.
ELECTRONIC COUNTER
CTR24L 2514
www.crouzet-control.com
Dehumidifiers
Counting operating hours,
energy consumption.
ELECTROMECHANICAL
HOUR AND ENERGY
COUNTER
CEM48
Milling machine
Combined ratemeter and
counter for controlling the
position and speed of a
router.
ELECTRONIC RATEMETER AND
COUNTERS
CTR24L 2513
Counters
and
Ratemeters
UV lamp
Counting and display of
operating times.
Event management,
wear control.
HOUR COUNTER
CTR24 2323
7
Selection guide
Electronic counters
24 x 48 multifunction counters without preselection
Functions
Totalizer
or Hour counter
or Ratemeter
Double totalizer
Independent inputs
(A and B)
Totalizer and
Ratemeter
Independent inputs
Double totalizer
Common input
Totalizer
+ Ratemeter
or Totalizer
+ Totalizer
or Totalizer + Hour
or Hour + Hour
Modes
Multiplication coefficient/
Decimal point
Max. counting speed
Dir/up.dn/up.up
Ph/2-ph/4-ph
Yes/Yes
50 kHz
Start/Stop
sec -1/min -1
No/Yes
Yes/Yes
999,999 hrs
50 kHz
Counting
A/B/A-B/A+B
AdivB/%AB
Yes/Yes
25 kHz
Yes/Yes
30 kHz
Yes/Yes
50 kHz
Yes/Yes
35 kHz
50 kHz
40 kHz
999,999 hrs
No/Yes
999,999 hrs
Max. counting speed
Display
99,999.99 hrs
LCD
99,999.99 hrs
Orange
(backlit)
99,999,999
LCD
99,999,999
Orange
(backlit)
Dir/up.dn/up.up
Ph/2-ph/4-ph
sec -1/min -1
Counting
(total/partial)
Counting + sec -1/min -1
Counting
Counting + Start/Stop
Start/Stop
24 x 48 counters without preselection
Functions
Inputs/Reset
PNP/Contact
Hour
NPN/Contact
Voltage/Contact
PNP/Contact
Hour
NPN/Contact
Voltage/Contact
Voltage/Contact
Totalizer
PNP/Contact
NPN/Contact
Voltage/Contact
PNP/Contact
Totalizer
NPN/Contact
Voltage/Contact
8
www.crouzet-control.com
Display
Counting capacity
Supply
Part number
Type
Page
10 C 30 V c
87 623 570
CTR24L - 2511
32
999,999
LED
0.001 s C 999,999 hrs
999,999
LED
999,999
10 C 30 V c
87 623 571
CTR24L - 2512
36
LED
999,999
10 C 30 V c
87 623 572
CTR24L - 2513
40
LED
999,999
10 C 30 V c
87 623 573
CTR24L - 2514
44
10 C 30 V c
87 623 574
CTR24L - 2515
48
999,999
LED
999,999
0.001 s C 999,999 hrs
Counters
and
Ratemeters
0.001 s C 999,999 hrs
Counting capacity
0.1 s C 99,999.99 hrs
0.1 s C 99,999.99 hrs
99,999,999
99,999,999
Supply
Lithium battery
Lithium battery
Lithium battery
Lithium battery
Part number
Type
Page
87 622 161
CTR24 - 2223
52
87 622 162
CTR24 - 2233
52
87 622 170
CTR24 - 2224
52
87 622 181
CTR24 - 2323
52
87 622 182
CTR24 - 2333
52
87 622 190
CTR24 - 2324
52
87 610 340
CP2 - 2108
52
87 622 061
CTR24 - 2241
56
87 622 062
CTR24 - 2251
56
87 622 070
CTR24 - 2242
56
87 622 081
CTR24 - 2341
56
87 622 082
CTR24 - 2351
56
87 622 090
CTR24 - 2342
56
The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet-control.com
www.crouzet-control.com
9
Selection guide
48 x 48 multifunction counters with preselection
Functions
Number of preset(s)
Preselection counter
Ratemeter
Chronometer
Multi-totalizer
1
Preselection counter
Ratemeter
Chronometer
Multi-totalizer
Batch counter
2
Preselection counter
Ratemeter
Chronometer
Multi-totalizer
1
Preselection counter
Ratemeter
Chronometer
Multi-totalizer
Batch counter
2
Max. counting speed
Display
40 KHz
Backlit LCD (orange)
extra-bright
2 lines
40 KHz
Two-colour LCD
(red and green)
2 lines
5 KHz
Backlit LCD (green)
2 lines
1
Preselection counter
Chronometer
2
Electromechanical counters
Hour counters
Dimensions (mm)
Counting capacity
48 x 48
99,999.99
48 x 48
999,999.99
24 x 48
15 x 32
Modular
DIN rail
35 mm
10
99,999.99
999,999.99
99,999.99
99,999.99
www.crouzet-control.com
Counting capacity
Outputs
1 x 5 A changeover
1 solid state
-999,999 C 999,999
1 x 5 A changeover
1 x 5 A N/O
2 solid state
1 x 5 A changeover
1 solid state
-999,999 C 999,999
1 x 5 A changeover
1 x 5 A N/O
2 solid state
1 x 3 A changeover
-999,999 C 999,999
1 x 3 A changeover
1 x 3 A N/O
Supply
Part number
Type
Page
10 C 30 V c
87 621 111
CTR48
18
24 V a
87 621 112
CTR48
18
90 C 260 V a
87 621 115
CTR48
18
10 C 30 V c
87 621 121
CTR48
18
24 V a
87 621 122
CTR48
18
90 C 260 V a
87 621 125
CTR48
18
10 C 30 V c
87 621 211
CTR48
18
24 V a
87 621 212
CTR48
18
90 C 260 V a
87 621 215
CTR48
18
10 C 30 V c
87 621 221
CTR48
18
24 V a
87 621 222
CTR48
18
90 C 260 V a
87 621 225
CTR48
18
11 C 30 V c
115 V a
230 V a
11 C 30 V c
115 V a
230 V a
87 629 111
87 629 113
87 629 114
87 629 121
87 629 123
87 629 124
CTR48E
CTR48E
CTR48E
CTR48E
CTR48E
CTR48E
26
26
26
26
26
26
Counters
and
Ratemeters
Frequency
50 Hz a
60 Hz a
c
50 Hz a
60 Hz a
c
c
50 Hz a
c
Supply
Part number
Type
Page
20 C 30 V a
42 C 48 V a
100 C 130 V a
360 C 440 V a
187 C 264 V a
20 C 30 V a
42 C 48 V a
100 C 130 V a
360 C 440 V a
187 C 264 V a
10 C 30 V c
36 C 80 V c
100 C 130 V c
20 C 30 V a
100 C 130 V a
187 C 264 V a
20 C 30 V a
100 C 130 V a
187 C 264 V a
10 C 30 V c
4.5 C 35 V c
24 V a
115 V a
230 V a
10 C 27 V c
99 772 710
99 772 711
99 772 712
99 772 713
99 772 714
99 772 718
99 772 719
99 772 715
99 772 717
99 772 716
99 772 810
99 772 811
99 772 812
99 782 710
99 782 712
99 782 714
99 782 718
99 782 715
99 782 716
99 782 810
99 792 810
99 793 710
99 793 712
99 793 714
99 793 810
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM48
CHM24
CHM24
CHM24
CHM24
CHM24
CHM24
CHM24
CHM15
CHMDR
CHMDR
CHMDR
CHMDR
60
60
60
60
60
60
60
60
60
60
60
60
60
62
62
62
62
62
62
62
64
65
65
65
65
The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet-control.com
www.crouzet-control.com
11
Selection guide
Impulse counters
Dimensions (mm)
Reset to zero
15 x 32
Clip-fixing
No
24 x 48
Clip-fixing
No
24 x 48
Clip-fixing
Yes
24 x 48
Screw-fixing
No
24 x 48
Screw-fixing
Yes
36 x 37
Screw-fixing
No
36 x 37
Screw-fixing
Yes
36 x 48
Screw-fixing
No
36 x 48
Screw-fixing
Yes
Dual function 48 x 48 counters
Functions
Reset to zero
Counting capacity
Impulse
Hour
No
9,999,999
99,999.99 hrs
9,999,999/999,999.99 hrs
Hour
Energy
12
No
99,999.9 hrs
99,999.9 kWh
www.crouzet-control.com
Counting capacity
9,999,999
999,999
99,999
999,999
99,999
999,999
99,999
999,999
99,999
Frequency
50 Hz a
60 Hz a
c
50 Hz a
Supply
Part number
Type
Page
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
5Vc
12 V c
24 V c
24 V a - 50/60 Hz
230 V a - 50/60 Hz
12 V c
24 V c
24 V a - 50/60 Hz
230 V a - 50/60 Hz
12 V c
24 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
110 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
110 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
48 V c
110 V c
24 V a - 50/60 Hz
115 V a - 50/60 Hz
230 V a - 50/60 Hz
24 V c
99 778 710
99 778 712
99 778 714
99 778 805
99 778 806
99 778 810
99 777 710
99 777 714
99 777 815
99 777 810
99 777 720
99 777 724
99 777 825
99 777 820
99 776 904
99 776 902
99 776 901
99 776 907
99 776 905
99 776 924
99 776 922
99 776 921
99 776 927
99 776 604
99 776 602
99 776 601
99 776 607
99 776 605
99 776 613
99 776 611
99 776 610
99 776 616
99 776 704
99 776 702
99 776 701
99 776 707
99 776 736
99 776 705
99 776 713
99 776 711
99 776 710
99 776 716
CIM 15
CIM 15
CIM 15
CIM 15
CIM 15
CIM 15
CIM 24
CIM 24
CIM 24
CIM 24
CIM 24
CIM 24
CIM 24
CIM 24
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 24 x 48
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 37
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
CIM 36 x 48
76
76
76
76
76
76
70
70
70
70
70
70
70
70
78
78
78
78
78
78
78
78
78
72
72
72
72
72
72
72
72
72
74
74
74
74
74
74
74
74
74
74
Supply
Part number
Type
Page
20 C 30 V a
100 C 130 V a
187 C 264 V a
20 C 30 V a
100 C 130 V a
187 C 264 V a
10 C 30 V c
115 V a
230 V a
99 779 710
99 779 712
99 779 714
99 779 718
99 779 715
99 779 716
99 779 810
99 780 712
99 780 714
CMM48
CMM48
CMM48
CMM48
CMM48
CMM48
CMM48
CEM48
CEM48
68
68
68
68
68
68
68
68
68
Counters
and
Ratemeters
The counters and ratemeters accessories guide is available on the product data sheets which can be downloaded from the website www.crouzet-control.com
www.crouzet-control.com
13
Connection diagrams
CTR24 counters
Connections
1. NC
2. Start/Stop input
3. Reset input
4. Enable front panel
Reset
5. Mode 1
(Time selection)
6. GND/Optional
backlighting (only 23xx)
7. Mode 2
(Time selection)
8. Optional
backlighting +
(only 23xx)
Types 2223 and 2323:
Types 2233 and 2333:
Part numbers:
• 87 622 161
• 87 622 181
Part numbers:
• 87 622 162
• 87 622 182
Types 2224 and 2324:
Part numbers:
• 87 622 170
• 87 622 190
14
1. Common z
2. Start/Stop input
3. Reset input
4. Enable front panel
Reset
5. Mode 1
(Time selection)
6. GND/Optional
backlighting (only 23xx)
7. Mode 2
(Time selection)
8. Optional
backlighting +
(only 23xx)
www.crouzet-control.com
1. Fast count
2. Slow count
3. Reset input
4. Enable front panel
Reset
5. Counting (counting
direction)
6. GND
7. Optional
backlighting (only 23xx)
8. Optional
backlighting +
(only 23xx)
Types 2241 and 2341:
Types 2251 and 2351:
Part numbers:
• 87 622 061
• 87 622 081
Part numbers:
• 87 622 062
• 87 622 082
Counters
and
Ratemeters
Types 2242 and 2342:
Part numbers:
• 87 622 070
• 87 622 090
www.crouzet-control.com
1. Fast count
2. Common z
3. Reset input
4. Enable front panel
Reset
5. NC
6. GND
7. Optional
backlighting (only 23xx)
8. Optional
backlighting +
(only 23xx)
15
Crouzet Control,
Technology and expertise,
behind every project
• Local support for all industrial projects.
• A multi-skilled team.
• A sales presence in over 40 countries.
• A Premium offer designed to ensure the excellence of products and services.
• Eco-design integrated in Crouzet's Offer Creation Process.
• Certifications: ISO 9001, ISO 14001, OHSAS 18001.
• Products which comply with international standards (UL, CSA, EC).
• A dynamic R&D department.
In addition to this catalogue, the www.crouzet-control.com
website offers the latest tools, available as free downloads,
including M3 Soft software, technical data sheets for each
product and installation manuals.
16
www.crouzet-control.com
Data sheets
• Up counters / Down counters - 48 x 48 - CTR48
P. 18
• Up counters / Down counters - 48 x 48 - CTR48E - Essential
P. 26
• Multifunction counter - LED 24 x 48 - CTR24L
P. 32
• Multifunction counter with 2 totalizers - LED 24 x 48 - CTR24L
P. 36
• Multifunction counter combining a totalizer and tachometer LED 24 x 48 - CTR24L
P. 40
• Multifunction counter with 2 totalizers (total an partial function) with common input LED 24 x 48 - CTR24L
P. 44
• "DUO" multifunction counter - LED 24 x 48 - CTR24L
P. 48
• Hour counters without preselection - LCD 24 x 48 - CTR24
P. 52
• Totalizers without preselection - LCD 24 x 48 - CTR24
P. 56
• Hour counters 48 x 48 - CHM48
P. 60
• Hour counters 24 x 48 - CHM24
P. 62
• Hour counters 15 x 32 - CHM15
P. 64
• DIN rail mounting hour counters - CHMDR
P. 65
• Dual-function counter (hour counter and watt-hour meter) 48 x 48 - CEM48
P. 66
• Dual-function counter (hour counter and impulse counter) 48 x 48 - CMM48
P. 68
• Impulse counters 24 x 48 - CIM24
P. 70
• Impulse counters 36 x 37 - CIM
P. 72
• Impulse counters 36 x 48 - CIM
P. 74
• Impulse counters with built-in fixing clip15 x 32 - CIM15
P. 76
• Screw-fixing implulse counters 24 x 48 - CIM
P. 78
To order:
Customer Service
Crouzet Control
Tel.: +33 (0) 475 802 102
customer.relation@crouzet.com
www.crouzet-control.com
17
Electronic multifunction counters with preselection
➜ Up counters / Down counters - 48 x 48 - CTR48
■ Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
■ Maximum input frequency 40 kHz
■ Simple parameter setting, configuration using text
menus
Easy modification of presets
Scaling factor
5 A changeover relay and solid state output
Removable connectors
Backlit LCD display (orange) : 2 lines, 6 digits or
multicoloured display (green-red)
■ IP 65 sealed panel
■ Option of locking the keypad, completely or partially
(preset, programming)
■ Accessories for 72 x 72 or 55 x 55 cut-out,
DIN rail adaptor
■
■
■
■
■
Part numbers
Type
Orange
backlight LCD
display
Multicoloured
LCD display
(green-red)
Functions
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Preselection
multi-totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Counter, Tachometer, Chronometer, Multi-totalizer,
Batch counter, Preselection totalizer
Preset
1
Voltages
10 ➞ 30 Vc
1
24 Va
1
90 ➞ 260 Va
2
10 ➞ 30 Vc
2
24 Va
2
90 ➞ 260 Va
1
10 ➞ 30 Vc
1
24 Va
1
90 ➞ 260 Va
2
10 ➞ 30 Vc
2
24 Va
2
90 ➞ 260 Va
Output
1 changeover relay,
1 solid state
1 changeover relay,
1 solid state
1 changeover relay,
1 solid state
1 changeover relay,
1 NO relay, 2 solid state
1 changeover relay,
1 NO relay, 2 solid state
1 changeover relay,
1 NO relay, 2 solid state
1 changeover relay,
1 solid state
1 changeover relay,
1 solid state
1 changeover relay,
1 solid state
1 changeover relay,
1 NO relay, 2 solid state
1 changeover relay,
1 NO relay, 2 solid state
1 changeover relay,
1 NO relay, 2 solid state
Code
87621111
87621112
87621115
87621121
87621122
87621125
87621211
87621212
87621215
87621221
87621222
87621225
Accessories
Description
Adaptor for 72 x 72 mm cut-out
Adaptor for 55 x 55 mm cut-out
DIN rail adaptor
1
18
Code
26546842
26546846
26546841
www.crouzet-control.com
General characteristics
Environmental characteristics
Supply
Relative humidity (no condensation)
Altitude
Certifications
Vibration resistance in 3 axes
Connection by screw terminals
Protection
Front panel watertight seal
Temperature limits use (°C)
Temperature limits stored (°C)
Weight (g)
General characteristics
Reset to zero or to preset
Minimum pulse time
Option to protect against reset from front panel
Scale factor (each input pulse is multiplied by this figure)
Scaling factor (each input impulse is divided by this value)
Decimal point selectable for ease of reading
Sensor supply version a
Programming and current value backed up via EEPROM memory
10 ➞ 30 Vc / 24 V a / 90 ➞ 260 Va
EN 60068-2-30 40/93% RLF
0 < 2000 m
UL - cULus (pending) - CE
10-55 Hz / 1 min / XYZ EN 60068-2-6: 30 min. in each direction
Removable
Conforming to standard EN 60529 IP65 for panel / IP20 for connections
✓
-20 ➞ +65
-25 ➞ +75
150 c version
250 a version
On panel: if not locked during programming
Electrical: automatic, voltage or solid state (NPN or PNP depending on
programming)
Impulse counter: < 15 ms
Chronometer: 500 µs
✓
00.0001 ➞ 99.9999
01.0000 ➞ 99.9999
0
0.0
0.00
0.000
0.0000
0.00000
24 Vc -20/+15% 50 mA
✓
Service life 10 years
Operating characteristics
Functions
Number of presets
Display
Height digits (mm)
Display details
Input characteristics
Inputs
Input modes
Input type
High level
Low level
Solid state output characteristics
Maximum current
Max. voltage
Relay output characteristics
Changeover relay
NO contact
Maximum current
Minimum current
Maximum voltage
Min. voltage
Response time
Mechanical life (operations)
Number of operations to 5 A
Output modes: maintained or pulsed
www.crouzet-control.com
Preselection counter, Tachometer, Chronometer, Multi-totalizer, Batch
counters, Totalizer
1 or 2
LCD with orange backlighting/Multicoloured LCD (green-red)
LCD 9
- 999 999 ➞ 999 999
2 counter inputs
1 reset input, 1 gate input
Dir: Directional
AS: up/dn
AA: up/up
PP: phase
PP2: phase 2
PP4: phase 4
Voltage or solid state
8 Vc ➞ 30 Vc
0 ➞ 2 Vc
30 mA
10 ➞ 30 Vc for the c version
24 Vc -20/+15%
✓
Depending on version
5A
10 mA
30 Vc / 250 Va
5 Vz
< 13 ms
20 x 106
5 x 104
0.01 ➞ 99.99 s
219
Dimensions (mm)
1
4,5
90,3
6 ±0,1
0
48
15,5
0
55 -0,2
45,4 +0,2
72
45,4
48
45
7,4
26546846 - Adaptor for 55 x 55 mm cut-out
48,1
26546842 - Adaptor for 72 x 72 mm cut-out
7,4 ±0,1
7
1 10.5 max.
45 +0.6
0
Panel cut-out
+0.6
45 0
26546841 - DIN rail adaptor
145
50 +0,5
0
22
5,5
75
83
15
41
70
Principles
Display and buttons
1
2
3
4
8
7
6
5
1 Current value
2 Selected value
3 Chronometer display
4 Active output indication
5 Prog/mode button
6 Preset control buttons
7 Button required for programming
parameters
8 Shows which value is displayed
3
20
www.crouzet-control.com
Connections
87621111 / 211
87621112 / 212
1
2
3
4
5
6
NC
7
1
2
3
4
5
6
NC
7
1
2
3
4
5
6
NC
7
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
9
10
11 12 13
NC NC
14 15
+
4
5
6
7
8
9
interconnected)
GND (0 Vc )
INP A (signal A input)
INP B (signal B input)
Reset (Reset input)
Gate input
Output 1 - 10-30 Vc /30 mA
11-12-13: Output 1
14-15: Supply
8
9
10
11
14 15
N~ L~
9
8
1 Sensor voltage supply
1 Sensor voltage supply
2 GND (0 Vc )
2 GND (0 Vc )
3 INP A (signal A input)
3 INP A (signal A input)
4 INP B (signal B input)
4 INP B (signal B input)
5 Reset (Reset input)
5 Reset (Reset input)
6 Gate input
6 Gate input
7 Output 1 - 24 V c /30 mA
7 Output 1 - 24 Vc /30 mA
8 11-12-13: Output 1
8 11-12-13: Output 1
9 14-15: Supply
9 14-15: Supply
Output: 5 A/250 Va / AC: 24 Va
87621125 / 225
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
10
11 12 13
14 15
10
11
interconnected)
GND (0 Vc )
INP A (signal A input)
INP B (signal B input)
Reset (Reset input)
Gate input
Output 1: 10-30 Vc /30 mA
Output 2: 10-30 Vc /30 mA
9-10: Output 1
11-12-13: Output 2
14-15: Supply
Output: 5 A/250 Va / AC: 90 ➞ 260 Vc
www.crouzet-control.com
9
10
11 12 13
14 15
9
10
11 12 13
N~ L~
-
1 Sensor voltage supply (* UB
7
11 12 13
NC NC
9
87621122 / 222
+
6
N~ L~
10
2
9
5
9
1
9
4
14 15
Output: 5 A/250 Va /AC: 24 Va
87621121 / 221
3
11 12 13
8
Output: 5 A/250 Va /AC: 24 Va
2
10
NC NC
1 Sensor voltage supply (* UB
3
9
-
9
8
2
87621115 / 215
9
10
11
14 15
N~ L~
9
10
1 Sensor voltage supply
1 Sensor voltage supply
2 GND (0 Vc )
2 GND (0 Vc )
3 INP A (signal A input)
3 INP A (signal A input)
4 INP B (signal B input)
4 INP B (signal B input)
5 Reset (Reset input)
5 Reset (Reset input)
6 Gate input
6 Gate input
7 Output 1: 24 Vc /30 mA
7 Output 1: 24 Vc /30 mA
8 Output 2: 24 Vc /30 mA
8 Output 2: 24 Vc /30 mA
11
9 9-10: Output 1
9 9-10: Output 1
10 11-12-13: Output 2
10 11-12-13: Output 2
11 14-15: Supply
11 14-15: Supply
Output: 5 A/250 Va / AC: 90 ➞ 260 Vc
Output: 5 A/250 Va / AC: 90 ➞ 260 Vc
421
Applications
Programming diagram
Cntr
tiMErC
tAcho
Input
PnP / npn
Input
PnP / npn
FrQ
HIGH / Low
FrQ
HIGH / Low
Low=30Hz HIGH=max
In.Cnt
dir / AS / AA / PP / PP2 / PP4
StArt
dir: Count direction
AS: Differential counting A-B
AA: Totalising A+B
PP: Quadrature Input
PP2: Quadrature with pulse doubling
PP4: Quadrature x4
rS0: Count mode Add (reset to zero)
rSP2: Count mode Sub (reset to main preset)
rSA0: Count mode Add with automatic reset
rSAP2: Count mode Sub with automatic reset
*bCrSA0: Count mode Add with automatic reset and batch counter
*tCrSA0: Count mode Add with automatic reset and total counter
MurS0: Multitotalizer (reset to zero)
diVidE 01,0000...99,9999
dEcPt
0 / 0,0 / 0,00 / 0,000 / 0,0000 / 0,00000
CoLor** rEd / rEdGm
Low=30Hz HIGH=max
FrQ
HIGH / Low
tcCb / tcCab / tcCbb / tcSb
tcSbb / tcSab / tcAuto
StArt
tA.AS / tA.AA / tA.PP
tA.A
Out.oP rS0 / rSA0 / rSAP2 / bCrSA0 /
rS0: Count mode Add (reset to zero)
rSP2: Count mode Sub (reset to main preset)
rSA0: Count mode Add with automatic reset
rSAP2: Count mode Sub with automatic reset
bCrSA0: Count mode Add with automatic reset and batch counter
tCrSA0: Count mode Add with automatic reset and total counter
tUnit
SEC / MIN / hour / h.Min.S /
dEcPt
0 / 0,0 / 0,00 / 0,000 / 0,0000 / 0,00000
tA.AS: Differential measurement A-B
tA.AA:Total measurement A+B
tA.PP: Freq. Measurement with direction (phase)
tA.A: Single frequency measurement
MultPI 00,0001...99,9999
tUnit
U.MIN / U.SEC
dEcPt
0 / 0,0 / 0,00 / 0,000 / 0,0000 / 0,00000
AVG
oFF / AVG2 / AVG5 / AVG 10 / AVG 20
rESMod no rEs / ELrES / Man.rE / Man.EL
norES: No reset
ELrEs: Electrical reset
ManrE: Manual reset
ManEL: Manual and electrical reset
Moving average
StuPtm 00.0..99,9
Start delay
CoLor rEd / rEdGm
**Only for multicolor version
Low=30Hz HIGH=max
diVidE 01,0000...99,9999
tCrSA0 / rSP2
*Only version 2 preset
MultPI 00,0001...99,9999
PnP / npn
tcCb: Start/Stop pulse duration on input B (comulative)
tcCab: Start edge to input A Stop edge to input B (comulative)
tcCbb: Start edge to input B Stop edge to input B (comulative)
tcSb: Start/Stop pulse duration on input B (single pulse)
tcSbb: Start edge to input B Stop edge to input B (single pulse)
tcSab: Start edge to input A Stop edge to input B (single pulse)
tcAuto: Control timing of reset
Out.oP rS0 / rSA0 / rSAP2 / bCrSA0 /
bCrSA2 / tCrSA0 / tCrSA2 /
bCrSo / bCrSP2 / tCrS0 / tCrSP2 / MurS0
Input
WAit0
rESMod no rEs / ELrES / Man.rE / Man.EL
norES: No reset
ELrEs: Electrical reset
ManrE: Manual reset
ManEL: Manual and electrical reset
00.0..99,9
Waiting time
CoLor** rEd / rEdGm
**Only for multicolor version
OutS1 on / oFF
S1
permanent signal
timed signal
tiMES1 00.01..99,99s
Time signal output regulation
P1
Counter
Output
rSo / rSP2
operation bCrS0
modes
bCrSP2
tCrS0
tCrSP2
MurS0
dir
40 kHz
AS
20 kHz
AA
PP
20 kHz
PP2
PP4
15 kHz
rSA0
5.2 kHz
4.4 kHz
4.2 kHz
4.2 kHz
2.2 kHz
2.1 kHz
1.1 kHz
1.0 kHz
Tachometer
tA.A
tA.AS
tA.AA
Quad
5
22
rSAP2
bCrSA0
bCrSA2
tCrSA0
tCrSA2
Loc: Preset value is locked
UnLoc: Preset value is open
UnLoc-tr: Preset valure is locked is possible to open with pression key with 10s
**OutS2 on / oFF
**S2
permanent signal
**Only version 2 preset
timed signal
tiMES1 00.01..99,99s
Time signal output regulation
P2
Loc / UnLoc / Loc-tr
PrG
Loc / UnLoc
40 kHz
20 kHz
Loc / UnLoc / Loc-tr
Loc: Preset value is locked
UnLoc: Preset value is open
UnLoc-tr: Preset valure is locked is possible to open with pression key with 10s
Loc: Press Key R and P into 15s after powerOn to enter in the programming
UnLoc: Press Key R and P for 3 sec to enter in the programming
www.crouzet-control.com
Curves
Counter: dir
Counter: AS
Counter: AA
dir
AS
AA
INP A
INP A
INP A
INP B
INP B
rS0
0
1
2
1
0
-1
-2
rSP2
P
P+1
P+2
P+1
P
P-1
P-2
Inp A: counter input
Inp B: count direction
rS0: Display 0 ➞ Preset
INP B
rS0
0
1
2
1
0
0
1
rSP2
P
P+1
P+2
P+1
P
P
P+1
Inp A: Add. counter input 1
Inp B: sub. counter input 2
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
rS0
0
1
Counter: PP
Counter: PP2
Counter: PP4
PP
PP2
PP4
INP A
INP A
INP A
INP B
INP B
4
6
7
INP B
rS0
0
1
2
3
2
1
0
rS0
0
1
2
3
4
3
2
rSP2
P
P+1
P+2
P+3
P+2
P+1
P
rSP2
P
P+1
P+2
P+3
P+4
P+3
P+2
A 90° B
Inp A: Counter input
Counting on a rising edge and on a
falling edge
Inp B: Reversal of direction
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
3
Inp A: Add. counter input 1
Inp B: sub. counter input 2
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
A 90° B
Inp A: Counter input
Counting on an edge
Inp B: Reversal of direction
rS0: Display 0 ➞ Preset
2
rSP2: Display Preset ➞ 0
rS0
0
rSP2
P
1
2
3
4
5
6
P+1 P+2 P+3 P+4 P+5 P+6
7
6
P+7
5
4
3
P+6 P+5 P+4 P+3
A 90° B
Inp A: Counter input
Counting on a rising edge and on a
falling edge
Inp B: Counter input
Counting on a rising edge and on a
falling edge, reversal of direction
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
Chronometer: Start tcCb
Chronometer: Start tcCbb
Chronometer: Start tcCAb
INP B
INP B
GATE
T1
T2
off
on
INP A
T1
off
ADD
0
...........
T1
T1+T2
SUB
P
...........
P-T1
P-T1-T2
Inp A: No function
Inp B: On/Off
Cumulative time counting
Add: Display 0 ➞ Preset
T2
ADD
0
...........
T1
T1+T2
SUB
P
...........
P-T1
P-T1-T2
Inp A: No function
Inp B: On/Off
Cumulative time counting
Add: Display 0 ➞ Preset
Sub: Display Preset ➞ 0
T2
GATE
off
on
ADD
0
...........
T1
SUB
P
...........
P-T1
.....................
T1+T2
SUB
P
P-T1
.....................
P-T1-T2
INP A
T1
off
T1
Chronometer: Start tcSAb
INP B
T1
T2
0
Sub: Display Preset ➞ 0
Chronometer: Start tcSbb
INP B
T1
ADD
Inp A: On
Inp B: Off
Cumulative time counting
Add: Display 0 ➞ Preset
Sub: Display Preset ➞ 0
Chronometer: Start tcSb
INP B
T2
off
T2
ADD
0
...........
T1
T2
P-T2
SUB
GATE
P
...........
P-T1
P-T2
ADD
0
T1
.....................
T2
SUB
P
P-T1
.....................
P-T2
Inp A: No function
Inp B: On/Off
Individual time counting while B is
active, automatic reset before each
new count
Add: Display 0 ➞ Preset
on
off
INP B
GATE
Inp A: No function
Inp B: On/Off
Individual time counting, automatic
reset before each new count
Add: Display 0 ➞ Preset
Sub: Display Preset ➞ 0
T1
T2
on
off
Inp A: On
Inp B: Off
Individual time counting, automatic
reset before each new count
Add: Display 0 ➞ Preset
Sub: Display Preset ➞ 0
Sub: Display Preset ➞ 0
www.crouzet-control.com
623
Chronometer: Start tcAuto
off
GATE
on
Tachometer: Start tA.A
off
RESET
PRESET
ADD
0
T2
T1
0 ..... T1 0 .....
T2
T3
..........
T4
T2 +T3 0 .....
SUB
P
P ..... P-T1 P .....
P-T2 ..........
P-T2-T3 P .....
Inp A: No function
Inp B: No function
Time counting command via Reset
(manual or electrical)
Add: Display 0 ➞ Preset
Tachometer: Start tA.AS
INP A
0
FA0
FA1
FA2
0
x
INP A
0
FA0
FA1
FA2
0
Display
0
0
FA0
FA1
FA2
0
INP B
0
0
FB0
FB1
FB2
Display
0
0
FA0
Inp A: Frequency input
Inp B: No function
FA0 - FB0 FA1 - FB1
x
x
- FB2
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula: A - B
Sub: Display Preset ➞ 0
The Gate input has a display memory
function
Tachometer: Start tA.AA
Tachometer: Start tA.PP
INP A
0
FA0
FA1
FA2
0
x
INP B
0
0
FB0
FB1
FB2
x
Display
0
0
FA0
FA0 + FB0 FA1 + FB1
FB2
Output operation: OutoP rS0
RESET
PR2
INP A
INP B
Display
0
fA0
fA1
fA2
fA3
fA4
fA5
0
FA0
FA1
FA2
-FA3
-FA4
PR1
COUNTER
OUT P1
OUT P2
Inp A: Frequency input 1
Inp B: Frequency input 2
Formula: A + B
A 90° B
Inp A: Frequency input 1
Inp B: Reversal of direction
Output operation: OutoP rSA0
Output operation: OutoP bCrSA0
RESET
PR2
PR1
COUNTER
RESET
PR2
RESET
PR2
COUNTER
COUNTER
OUT P1
PR1
BATCH
OUT P2
OUT P1
OUT P2
Output operation: OutoP rSP2
Output operation: OutoP tCrSA0
Output operation: OutoP rSAP2
RESET
RESET
PR2
PR2
PR1
PR1
COUNTER
COUNTER
OUT P1
OUT P1
OUT P2
OUT P2
PR1
TOTAL
OUT P1
OUT P2
Output operation: OutoPbCrSA2
RESET
PR2
COUNTER
PR1
BATCH
OUT P1
OUT P2
7
24
www.crouzet-control.com
Output operation: OutoP tCrSA2
RESET
PR2
RESET
PR2
COUNTER
PR1
TOTAL
Output operation: OutoP bCrS0
COUNTER
0
PR1
OUT P1
BATCH
OUT P2
OUT P1
OUT P2
Output operation: OutoP MurS0 (AA)
RESET Inp.
RESET Man.
A
B
PR1
Output operation: OutoP bCrSP2
RESET
PR2
COUNTER
COUNTER A
PR1
OUT P1
BATCH
PR2
OUT P1
COUNTER B
OUT P2
OUT P2
Output operation: OutoP tCrS0
RESET
PR2
COUNTER
PR1
TOTAL
OUT P1
OUT P2
Output operation: OutoP tCrSP2
RESET
PR2
COUNTER
PR1
TOTAL
OUT P1
OUT P2
COUNTER A+B
Output operation: OutoP MurS0 (AS)
RESET Inp.
RESET Man.
A
B
PR1
COUNTER A
OUT P1
PR2
COUNTER B
OUT P2
COUNTER A+B
www.crouzet-control.com
8 25
Electronic multifunction counters with preselection
➜ Up counters/Down counters - 48 x 48 - CTR48E "Essential"
■ Counter, Preselection chronometer
■ Maximum input frequency 5 k Hz
■ Simple parameter setting, configuration
using text menus
Easy modification of presets
Multiplication factor
3 A changeover relay
Backlit LCD display (green) : 6 digits, height 9 mm
IP 65 sealed panel
Option of locking the keypad, completely or partially
(preset, programming)
■ Accessories for 72 x 72 or 55 x 55 cut-out,
DIN rail adaptor
■
■
■
■
■
■
Part numbers
Type
Green backlit
LCD display
Functions
Counter, Preselection chronometer
Counter, Preselection chronometer
Counter, Preselection chronometer
Counter, Preselection chronometer
Preset
1
1
1
2
Voltages
10 ➞ 30 Vc
115 Va
230 Va
10 ➞ 30 Vc
Counter, Preselection chronometer
2
115 Va
Counter, Preselection chronometer
2
230 Va
Output
1 relay
1 relay
1 relay
1 changeover relay,
1 NO relay
1 changeover relay,
1 NO relay
1 changeover relay,
1 NO relay
Code
87629111
87629113
87629114
87629121
87629123
87629124
Accessories
Description
Adaptor for 72 x 72 mm cut-out
Adaptor for 55 x 55 mm cut-out
DIN rail adaptor
Code
26546842
26546846
26546841
General characteristics
Environmental characteristics
Supply
Relative humidity (no condensation)
Altitude
Certifications
Vibration resistance in 3 axes
Connection by screw terminals
Protection
Front panel watertight seal
Temperature limits use (°C)
Temperature limits stored (°C)
Weight (g)
General characteristics
Reset to zero or to preset
Minimum pulse time
Option to protect against reset from front panel
Scale factor (each input pulse is multiplied by this figure)
Decimal point selectable for ease of reading
Sensor supply version a
Programming and current value backed up via EEPROM memory
11 ➞ 30 Vc / 115 V a / 230 Va
EN 60068-2-30 40/93% RLF
0 < 2000 m
CE
10-55 Hz/1 min/XYZ EN 60068-2-6: 30 min. in each direction
Removable
Conforming to standard EN 60529 IP65 for panel/IP20 for connections
✓
-10 ➞ +50
-25 ➞ +75
150 c version
250 a version
On panel: if not locked during programming
Electrical: automatic, voltage or solid state (NPN or PNP depending on
programming)
Impulse counter: < 15 ms
Chronometer: 500 µs
✓
00.0001 ➞ 99.9999
0
0.0
0.00
0.000
0.0000
0.00000
-40/+15% 50 mA 230 Va
-40/+15% 40 mA 115 Va
✓
Service life 10 years
1
26
www.crouzet-control.com
Operating characteristics
Functions
Number of presets
Display
Height digits (mm)
Display details
Input characteristics
Inputs
Preselection counter, Chronometer
1 or 2
LCD with green backlighting
LCD 9
- 999 999 ➞ 999 999
2 counter inputs
1 reset input, 1 locking input
Dir: Directional
AS: up/dn
PP: phase
Voltage or solid state
3.5 ➞ 30 Vc
0 ➞ 2 Vc
Input modes
Input type
High level
Low level
Relay output characteristics
Changeover relay
NO contact
Maximum current
Minimum current
Maximum voltage
Min. voltage
Response time
Mechanical life (operations)
Number of operations
Output modes: maintained or pulsed
✓
Depending on version
3A
30 mA
30 Vc / 250 Va
5 Vz
< 10 ms
20 x 106
1 x 105
0.01 ➞ 99.99 s
Dimensions (mm)
Panel cut-out
26546842 - Adaptor for 72 x 72 mm cut-out
1
72
45,4
48
45
45 +0.6
0
7,4
48
4,5
15,5
90,3
7
+0.6
45 0
1 10.5 max
26546846 - Adaptor for 55 x 55 mm cut-out
0
0
48,1
6 ±0,1
45,4 +0,2
55 -0,2
7,4 ±0,1
26546841 - DIN rail adaptor
145
50 +0,5
0
22
75
83
5,5
15
41
70
www.crouzet-control.com
227
Connections
87629111
87629113 / 114
1
2
3
4
5
6
1
2
3
4
5
6
NC NC
7
7
8
NC NC
9
11 12 13
10
8
3
4
5
6
7
8
9
1
2
3
4
5
6
1
2
3
4
5
6
NC NC
7
7
9
NC NC
14 15
1 Sensor voltage supply (* UB
2
87629121
9
10
2
3
4
5
6
1
2
3
4
5
6
11 12 13
14 15
2 GND (0 Vc )
3 INP A (signal A input)
4 INP B (signal B input)
5 Reset (Reset input)
6 Lock (locking switch input)
7 11-12-13: Output 1
8 14-15: Supply
NC NC
7
9
9
8
8
7
8
N~ L~
1 Sensor voltage supply
interconnected)
GND (0 Vc )
INP A (signal A input)
INP B (signal B input)
Reset (Reset input)
Lock (locking switch input)
11-12-13: Output 1
14-15: Supply
Power supply - GND
8
1
10
11 12 13
10
14 15
1 Sensor voltage supply (* UB
interconnected)
2 GND (0 Vc )
3 INP A (signal A input)
4 INP B (signal B input)
5 Reset (Reset input)
6 Lock (locking switch input)
7 9-10: Output 1
8 11-12-13: Output 2
9 14-15: Supply
10 Power supply - GND
87629123 / 124
1
2
3
4
5
6
1
2
3
4
5
6
NC NC
7
8
7
8
9
N~ L~
9
10
11 12 13
14 15
1 Sensor voltage supply
2 GND (0 Vc )
3 INP A (signal A input)
4 INP B (signal B input)
5 Reset (Reset input)
6 Lock (locking switch input)
7 9-10: Output 1
8 11-12-13: Output 2
9 14-15: Supply
3
28
www.crouzet-control.com
Applications
Programming diagram
Cntr
tiMErC
Input
PnP / npn
Input
PnP / npn
FrQ
HIGH / Low
FrQ
HIGH / Low
In.Cnt
dir / AS / PP
StArt
tcCab / tcCbb / FrErun
Low=30Hz HIGH=max
Loc
dir: Count direction
AS: Differential counting A-B
PP: Quadrature Input
Low=30Hz HIGH=max
FrErun: Gate Mode (INPA)
tcCab: Start edge to input A Stop edge to input B (comulative)
tcCbb: Start edge to input B Stop edge to input B (comulative)
ProG / PrESEt / PrgPrE
ProG: Programming us locked
PrESEt: Preset value us locked
PrgPrE: Preset and programming us locked
Loc
(The activation is with the electrical input LOCK)
(the choice is valid for P1 and P2 in the case of version to two pres.)
Out.oP rS0 / rSA0 / rSAP2 / rSP2
rS0: Count mode Add (reset to zero)
rSP2: Count mode Sub (reset to main preset)
rSA0: Count mode Add with automatic reset
rSAP2: Count mode Sub with automatic reset
ProG / PrESEt / PrgPrE
ProG: Programming us locked
PrESEt: Preset value us locked
PrgPrE: Preset and programming us locked
(The activation is with the electrical input LOCK)
(the choice is valid for P1 and P2 in the case of version to two pres.)
Out.oP rS0 / rSA0 / rSAP2 / rSP2
rS0: Count mode Add (reset to zero)
rSP2: Count mode Sub (reset to main preset)
rSA0: Count mode Add with automatic reset
rSAP2: Count mode Sub with automatic reset
MultPI 00,0001...99,9999
tUnit
SEC / MIN / hour / h.Min.S /
dEcPt
dEcPt
0 / 0,0 / 0,00 / 0,000 / 0,0000 / 0,00000
0 / 0,0 / 0,00 / 0,000 / 0,0000 / 0,00000
rESMod no rEs / ELrES / Man.rE / Man.EL
norES: No reset
ELrEs: Electrical reset
ManrE: Manual reset
ManEL: Manual and electrical reset
rESMod no rEs / ELrES / Man.rE / Man.EL
norES: No reset
ELrEs: Electrical reset
ManrE: Manual reset
ManEL: Manual and electrical reset
S1
permanent signal
timed signal
tiMES1 00.01..99,99s
Time signal output regulation
Low : 1.0 V
High : 4.0 V
rS0
rSA0
rSP2
rSAP2
dir 15 kHz
1.5 kHz
AS 10 kHz
1.5 kHz
PP 10 kHz
0.7 kHz
www.crouzet-control.com
Low : 3.0 V
High : 30.0 V
rS0
rSA0
rSP2
rSAP2
5 kHz
1.2 kHz
5 kHz
1.2 kHz
2.4 kHz 0.5 kHz
**S2
permanent signal
**Only version 2 preset
timed signal
tiMES1 00.01..99,99s
Time signal output regulation
429
Curves
Counter: dir
Counter: AS
Counter: PP
dir
AS
PP
INP A
INP A
INP A
INP B
INP B
rS0
0
1
2
1
0
-1
-2
rSP2
P
P+1
P+2
P+1
P
P-1
P-2
A 90° B
Inp A: Counter input
Counting on an edge
Inp B: Reversal of direction
rS0: Display 0 ➞ Preset
INP B
rS0
0
1
2
1
0
0
1
rSP2
P
P+1
P+2
P+1
P
P
P+1
Inp A: Add. counter input 1
Inp B: Sub. counter input 2
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
Chronometer: Start tcCbb
2
3
2
1
0
P+1
P+2
P+3
P+2
P+1
P
Chronometer: Start FrErun
INP A
(GATE)
INP B
INP A
T1
INP B
T2
ADD
0
T1
.....................
T1+T2
SUB
P
P-T1
.....................
P-T1-T2
Sub: Display Preset ➞ 0
1
P
rSP2: Display Preset ➞ 0
Chronometer: Start tcCAb
Inp A: On
Inp B: Off
Add: Display 0 ➞ Preset
0
rSP2
A 90° B
Inp A: Counter input
Counting on an edge
Inp B: Reversal of direction
rS0: Display 0 ➞ Preset
rSP2: Display Preset ➞ 0
T1
rS0
T2
active
ADD
0
...........
T1
T1+T2
ADD
0
T1
...........
SUB
P
...........
P-T1
P-T1-T2
SUB
P
...........
Inp A: No function
Inp B: On/Off
RS0/RSP2
Add: Display 0 ➞ Preset
active
T1
T2
...........
T1+T2
P-T1
...........
P-T1-T2
InpA: Gate
Time measurement via InpA
InpB: No function
Sub: Display Preset ➞ 0
Output operation 1: rS0
Output operation 1: rSP2
RESET
S1
RESET
S1
RESET
S1
COUNTER
COUNTER
COUNTER
OUT S1
OUT S1
OUT S2
Output operation 1: rSAP2
RESET
S1
COUNTER
OUT S2
Output operation 2: rSP2
5
30
Output operation 1: rSA0
Output operation 2: rS0
Output operation 2: rSA0
RESET
S2
RESET
S2
PR1-PR3-PR4
PR1-PR3-PR4
COUNTER
COUNTER
OUT P1-P3-P4
OUT P1-P3-P4
OUT S2
OUT S2
Output operation 2: rSAP2
RESET
S2
RESET
S2
PR1-PR3-PR4
PR1-PR3-PR4
COUNTER
COUNTER
OUT P1-P3-P4
OUT P1-P3-P4
OUT S2
OUT S2
www.crouzet-control.com
Crouzet Control,
Technology and expertise,
behind every project
• Local support for all industrial projects.
• A multi-skilled team.
• A sales presence in over 40 countries.
• A Premium offer designed to ensure the excellence of products and services.
• Eco-design integrated in Crouzet's Offer Creation Process.
• Certifications: ISO 9001, ISO 14001, OHSAS 18001.
• Products which comply with international standards (UL, CSA, EC).
• A dynamic R&D department.
In addition to this catalogue, the www.crouzet-control.com
website offers the latest tools, available as free downloads,
including M3 Soft software, technical data sheets for each
product and installation manuals.
To order:
Customer Service
Crouzet Control
Tel.: +33 (0) 475 802 102
customer.relation@crouzet.com
www.crouzet-control.com
31
Electronic multifunction counters without preselection
➜ Multifunction counter - LED 24 x 48 - CTR24L
■ High brightness display: 6-digit LED, height 8 mm
■ Maximum input frequency 50 k Hz
■ Programmable multifunction: Counter/Tachometer/
Chronometer
Reset on panel or external with inhibition option
Supply: 10 ➞ 30 Vc
Easy to program
Scaling factor (Counter - Tachometer)
Decimal point (Counter - Tachometer)
Timing range 0.001 s ➞ 999.999 hrs (Chronometer)
Impulses or time measured in hrs/min/sec and in real
time (Chronometer)
■ Accessories for 50 x 25 mm cut-out
■
■
■
■
■
■
■
Part numbers
Type
CTR24L - 2511
Functions
Counter, Tachometer, Chronometer
Code
87623570
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 5 screw terminals at rear of casing
Connection capacity
Fixed using bracket
Degree of protection front face
Data memory
Temperature limits use (°C)
Temperature limits stored (°C)
Dielectric strength
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Functions
Display
Height digits (mm)
Input characteristics
Inputs
High level
Low level
Cyclical ratio
Polarity
Minimum impulse duration for reset
Frequency of filtered input
Input impedance (kΩ)
Impulse counter
Display details
Elimination of non-significant zeros
1
32
10 ➞ 30 Vc max 55 mA with protection against polarity reversal
✓
1.5 mm2
✓
IP 65
EEPROM
-20 ➞ +55
-25 ➞ +70
According to EN 61010-1: 2000 V/50 Hz/1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Impulse counter, Tachometer, Chronometer
6-digit LED
8
2 counter inputs, 1 reset input
0 ➞ 0.2 x Ub Vc
0.6 x Ub ➞ 30 Vc
Any (maximum frequency given for a cyclical ratio = 1/1)
Schmitt trigger input
NPN or PNP for all inputs (programming)
5 ms
Filter active: 30 Hz
Filter disabled: maximum frequency (programming)
Appr. 5
- 19 999 ➞ 999 999
✓
www.crouzet-control.com
Counting input modes
Inputs INPA / INPB
Reset input (terminal 5)
Reset to zero - Panel
Remise à zéro - Externe (borne 5)
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Tachometer
Display details
Elimination of non-significant zeros
Conversion time
Input INPA
Accuracy
Measurement principle
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Chronometer
Display details
Elimination of non-significant zeros
Functions
Input INPA
Input INPB
Remise à zéro - Externe (borne 5)
Reset input (terminal 5)
Reset to zero - Panel
Accuracy
Decimal point
Time ranges
www.crouzet-control.com
Cnt.Dir ➞ Counter input INPA and counter direction input INPB
Up.dn ➞ INPA INPB differential counting
Up.up ➞ Sum of INPA + INPB
QuAd ➞ Phase discriminator
QuAd2 ➞ Phase discriminator with doubling of impulses
QuAd4 ➞ Phase discriminator with quadrupling of impulses
Dynamic
Dynamic Reset input connected in parallel with the red SET/RESET button
Sets the counter to the defined preset value
If not locked during programming
If not locked during programming
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
CntDir ➞ 50 kHz
UpDown ➞ 25 kHz
UpUp ➞ 25 kHz
Quad1 ➞ 25 kHz
Quad2 ➞ 25 kHz
Quad4 ➞ 15 kHz
0 ➞ 999 999
✓
1/s ou 1/min
Dynamic
< 0.1%
< 38 Hz: measurement of period duration
> 38 Hz: measurement with duration time base = 26.3 ms
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
50 kHz
0.001 s ➞ 999 999 h
✓
GatE.Lo ➞ Time measurement if INPB is not active
GatE.hi ➞ Time measurement if INPB is active
Inb.Inb ➞ Time measurement on/off via the INPB edge
InA.Inb ➞ Measurement on via the INPA edge, measurement off via the
INPB edge
Start
Start/Stop or Gate (depends on the input mode chosen)
If not locked during programming
Dynamic Reset input connected in parallel with the red SET/RESET button
Sets the counter to the defined preset value
If not locked during programming
< 50
0
0.0
0.00
0.000
0.001 s ➞ 999 999 s
0.001 min ➞ 99 999 min
0.001 h ➞ 999 999 h
00 h 00 min 01 s ➞ 99 h 59 min 59 s
233
Dimensions (mm)
CTR24L - 2511
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24L
2
22x45
19,3
4
6,5
59
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
Connections
1
2
3
4
5
1 Supply: 10 ➞ 30 Vc
2 Supply: GND (0 Vc )
3 INPA
4 INPB (NC in tachometer mode)
5 SET/RESET (NC in tachometer mode)
3
34
www.crouzet-control.com
Applications
Programming diagram
2511
CTR24L
ModE
Count
tAcho
InPol
FiltEr
PnP
nPn
oFF
on
InPol
FiltEr
Filter on 30Hz – off Fmax
QuAd
InPut
Cntdir
QuAd2
uP.dn
01.0000
QuAd4
uP.uP
diUiSo
FActor
diUiSo
on
FiltEr
01.0000
0.00
StArt
99.9999
0.00
0.000
tMode
rESet
MAnrE
MAnEl
norES
000000
InA.Inb
GatE.Lo
GatE.hI
hour
h.Min.s
SEC
MIn
s/h/min (accurancy depending on position
of the decimal point)
MIn-1
0
dP
0.0
0.00
ELrES
MAnrE
MAnEl
norES
Decimal point
Wait0
00.1
99.9
rESet
EndPro
0.000
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
SEtPt
000000
999999
The device will be set to the set point
by pressing the red key or activating
the set/reset input
999999
The device will be set to the set point by pressing
the red key or activating the set/reset input
EndPro
EndPro
Count frequency:
DC power supply
Input level
typ. low
typ. High
Fmax*
CntDir
UpDown
Up.up
Quad1
Quad2
Quad4
Inb.Inb
h.m.s (decimal point setting is ignored)
SEC-1
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
SEtPt
on
Time units:
Max time to wait 00.1…..99.9s
ELrES
oFF
count Stop with INPB edge
SEC-1: Value conversion and display in 1/s
Min-1: Value conversion and display in 1/m
0.000
nPn
GatE.Lo: Counting while INPB is inactive
GatE.hi: Counting while INPB is active
Inb.Inb: Count Start/Stop whit INPB edge
InA.Inb: Count Start whit INPA edge,
0
0.0
PnP
Filter on 30Hz – off Fmax
99.9999
Dividing factor
0
Decimal point
oFF
Multiplying factor
diSPn
99.9999
Dividing factor
0.0
InPol
Decimal point
01.0000
dP
nPn
01.0000
dP
99.9999
Multiplying factor
PnP
Filter on 30Hz – off Fmax
Cnt.Dir: Count input INPA +count direction INPB
Up.dn: Differential count INPA – INPB
Up.up: Totalising INPA + INPB
QuAd : Count Up/Down INPA 90° INPBx1
QuAd2: Count Up/Down INPA 90° INPBx2
QuAd4: Count Up/Down INPA 90° INPBx4
FActor
timEr
Count frequency:
24V
12V
Standard
2.5V
2.0V
22.0V
10V
kHz
kHz
50
20
25
15
25
15
25
15
25
15
15
15
www.crouzet-control.com
DC power supply
Input level
typ.low
typ. Hight
Fmax*
Tacho
Counting ranges:
24V
12V
Standard
2.5V
2.0V
22.0V
10V
kHz
kHz
50
20
Seconds
Minutes
Hours
h.min.s
0,001s...999 999s
0,001min...999 999min
0,001h...999 999h
00h00min01s...99h59min59s
435
Electronic multifunction counters without preselection
➜ Multifunction counter with 2 totalizers - LED 24 x 48 - CTR24L
■ High brightness display: 6-digit LED, height 8 mm
■ Maximum input frequency 25 k Hz
■ Counter with 2 separate totalizers, each with a
■
■
■
■
■
■
dedicated input
Reset on panel or external with inhibition option
Supply: 10 ➞ 30 Vc
Easy to program
Scaling factor
Decimal point
Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24L - 2512
Functions
Counter with 2 separate totalizers
Code
87623571
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 5 screw terminals at rear of casing
Terminal capacity
Fixed using bracket
Degree of protection front face
Data memory
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Functions
Display
Height digits (mm)
Input characteristics
Inputs
Low level
High level
Cyclical ratio
Polarity
Minimum impulse duration for reset
Frequency of filtered input
Input impedance (kΩ)
Impulse counter
Display details
Display
Elimination of non-significant zeros
Counting input modes
1
36
10 ➞ 30 Vc max 55 mA with protection against polarity reversal
✓
1.5 mm2
✓
IP 65
EEPROM
-20 ➞ +55
-20 ➞ +55
EN 61010-1: 2000 V / 50 Hz / 1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Counter with 2 separate totalizers
6-digit LED
8
2 counter inputs, 1 reset input
0 ➞ 0.2 x Ub Vc
0.6 x Ub ➞ 30 Vc
Any (maximum frequency given for a cyclical ratio = 1/1)
Schmitt trigger input
NPN or PNP for all inputs (programming)
5 ms
Filter active: 30 Hz
Filter disabled: maximum frequency (programming)
Appr. 5
0 ➞ 999 999
When the buttons are pressed, the counter displays the following values:
CntA ➞ Value of counter A (INPA input)
CntB ➞ Value of counter B (INPB input)
Asubb ➞ Difference between A-B (INPA-INPB input)
Aaddb ➞ Addition of A+B (INPA+INPB input)
AdIUb ➞ Division of A/B (INPA/INPB input)
Aprocb ➞ Percentage (A-B) /A ( (INPA-INPB) /INPA input)
✓
CntA ➞ INPA input counting
CntB ➞ INPB input counting
www.crouzet-control.com
Inputs INPA / INPB
Reset input (terminal 5)
Dynamic
Dynamic Reset input connected in parallel with the red SET/RESET button
Sets the counter to the defined preset value - possible on both totalizers
If not locked during programming
If not locked during programming
1 ➞ 99.9999 (separate for A and B)
1 ➞ 99.9999 (separate for A and B)
0
0.0
0.00
0.000
25 k Hz
Reset to zero - Panel
Reset to zero - External (borne 5)
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Dimensions (mm)
CTR24L - 2512
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24L
2
22x45
19,3
4
6,5
59
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
Connections
1 Supply: 10 ➞ 30 Vc
1
2
3
4
5
2 Supply: GND (0 Vc )
3 INPA
4 INPB
5 SET/RESET
www.crouzet-control.com
237
Applications
Programming diagram
2512
Count frequency:
DC power supply
Input level
typ. low level
typ. high level
Fmax*
tot.tot
CTR24L
InPol
FiltEr
PnP
nPn
oFF
on
24V
12V
Standard
2.5V
2.0V
22.0V
10V
kHz
kHz
25
15
Filter on 30Hz – off Fmax
Counter A
FAcCnA
01.0000
99.9999
01.0000
99.9999
Multiplying factor
diVCnA
Dividing factor
FAcCnb
0.0
0.00
ELrES
MAnrE
MAnEl
norES
Decimal point
reSCnA
01.0000
99.9999
01.0000
99.9999
Multiplying factor
diVCnb
Dividing factor
0
dPCnA
Counter B
dPCnb
0.000
0
0.0
0.00
ELrES
MAnrE
MAnEl
norES
Decimal point
reSCnb
0.000
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
EndPro
SELECTION OF THE DISPLAYED VALUE
CTR24L
Pressing the right key
displays successively the
following varius values
3
38
CntA
Value of counter A (Input INPA)
CntB
Value of counter B (Input INPB)
Asubb
Asubb: Difference A-B (input INPA-INPB)
Aaddb
Aaddb: Sum A+B (Input INPA+INPB)
AdlUb
AdIUb: Quotient A/B (Input INPA/INPB)
Aprocb
Aprocb: Percentage (A-B)/A ( Input (INPA-INPB)/INPA )
www.crouzet-control.com
Crouzet Control,
Technology and expertise,
behind every project
• Local support for all industrial projects.
• A multi-skilled team.
• A sales presence in over 40 countries.
• A Premium offer designed to ensure the excellence of products and services.
• Eco-design integrated in Crouzet's Offer Creation Process.
• Certifications: ISO 9001, ISO 14001, OHSAS 18001.
• Products which comply with international standards (UL, CSA, EC).
• A dynamic R&D department.
In addition to this catalogue, the www.crouzet-control.com
website offers the latest tools, available as free downloads,
including M3 Soft software, technical data sheets for each
product and installation manuals.
To order:
Customer Service
Crouzet Control
Tel.: +33 (0) 475 802 102
customer.relation@crouzet.com
www.crouzet-control.com
39
Electronic multifunction counters without preselection
➜ Multifunction counter combining a totalizer and tachometer - LED 24 x 48 - CTR24L
■ High brightness display: 6-digit LED, height 8 mm
■ Maximum input frequency 30 k Hz
■ Combined function: Position indicator counter and
■
■
■
■
■
■
Tachometer
Reset on panel
Supply: 10 ➞ 30 Vc
Easy to program
Scaling factor (Counter - Tachometer)
Decimal point (Counter - Tachometer)
Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24L - 2513
Functions
Combined: Counter and Tachometer
Code
87623572
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 5 screw terminals at rear of casing
Terminal capacity
Fixed using bracket
Degree of protection front face
Data memory
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Functions
Display
Height digits (mm)
Input characteristics
Inputs
Low level
High level
Cyclical ratio
Polarity
Minimum impulse duration for reset
Frequency of filtered input
Input impedance (kΩ)
Impulse counter
Display details
Elimination of non-significant zeros
Counting input modes
Inputs INPA / INPB
Reset to zero - Panel
1
40
10 ➞ 30 Vc max 55 mA with protection against polarity reversal
✓
1.5 mm2
✓
IP 65
EEPROM
-20 ➞ +55
-25 ➞ +70
According to EN 61010-1: 2000 V / 50 Hz / 1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Impulse counter and Tachometer
6-digit LED
8
2 counter inputs, 1 tachometer input, 1 reset input
0 ➞ 0.2 x Ub Vc
0.6 x Ub ➞ 30 Vc
Any (maximum frequency given for a cyclical ratio = 1/1)
Schmitt trigger input
NPN or PNP for all inputs (programming)
5 ms
Filter active: 30 Hz
Filter disabled: maximum frequency (programming)
Appr. 5
- 19 999 ➞ 999 999
✓
Cnt.Dir ➞ Counter input INPA and counter direction input INPB
Up.dn ➞ INPA INPB differential counting
Up.up ➞ Sum of INPA + INPB
QuAd ➞ Phase discriminator
QuAd2 ➞ Phase discriminator with doubling of impulses
QuAd4 ➞ Phase discriminator with quadrupling of impulses
Dynamic
If not locked during programming
www.crouzet-control.com
Scale factor
Scaling factor
Decimal point
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
Combined Counter + Tachometer functions:
CntDir ➞ 30 kHz
UpDown ➞ 10 kHz
UpUp ➞ 10 kHz
Quad1 ➞ 15 kHz
Quad2 ➞ 15 kHz
Quad4 ➞ 10 kHz
Maximum counting frequency
Tachometer
Display details
Elimination of non-significant zeros
Conversion time
Input INPC
Accuracy
Measurement principle
0 ➞ 999 999
✓
1/s or 1/min
Dynamic
< 0.1%
< 38 Hz: measurement of period duration
> 38 Hz: measurement with duration time base = 26.3 ms
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
30 kHz
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Dimensions (mm)
CTR24L - 2513
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24L
2
22x45
19,3
4
59
6,5
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
www.crouzet-control.com
241
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
Connections
1
2
3
4
5
1 Supply: 10 ➞ 30 Vc
2 Supply: GND (0 V c )
3 INPA (Counter)
4 INPB (Counter)
5 INPC (Tachometer)
3
42
www.crouzet-control.com
Applications
Programming diagram
2513
Count frequency:
DC power supply
Input level
typ. low level
typ. high level
Fmax*
CntDir/Tacho
UpDown/Tacho
Up.up/Tacho
Quad1/Tacho
Quad2/Tacho
Quad4/Tacho
CTR24L
InPol
PnP
nPn
24V
12V
Standard
2.5V
2.0V
22.0V
10V
kHz
kHz
30
10
10
10
10
10
15
10
15
10
10
8
Tachometers
Counter
FiltEr
oFF
Fac.tAc
on
Filter on 30Hz – off Fmax
InPut
01.0000
99.9999
01.0000
99.9999
Multiplying factor
QuAd
QuAd2
QuAd4
Cntdir
uP.dn
uP.uP
Cnt.Dir: Count input INPA +count direction INPB
Up.dn: Differential count INPA – INPB
Up.up: Totalising INPA + INPB
QuAd : Count Up/Down INPA 90° INPBx1
QuAd2: Count Up/Down INPA 90° INPBx2
QuAd4: Count Up/Down INPA 90° INPBx4
diV.tAc
Dividing factor
dP.tAc
0
0.0
Decimal point
FAc.Cnt
01.0000
Multiplying factor
diV.Cnt
01.0000
Dividing factor
0.0
Decimal point
diSPn
99.9999
0.00
SEC-1
MIn-1
00.1
99.9
SEC-1: Value conversion and display in 1/s
Min-1: Value conversion and display in 1/m
Wait0
0.000
Max time to wait 00.1…..99.9s
MAnrE
reS.Cnt
0.000
99.9999
0
dP.Cnt
0.00
EndPro
norES
ManE: manual reset red Key
norES: no reset (red key locked)
SELECTION OF THE DISPLAYED VALUE
CTR24L
Count
Counter (position indicator)
tAcho
Tachometers
Pressing the right key
displays successively the
following varius values
www.crouzet-control.com
443
Electronic multifunction counters without preselection
➜ Multifunction counter with 2 totalizers (total and partial function)
with common input - LED 24 x 48 - CTR24L
■ High brightness display: 6-digit LED, height 8 mm
■ Maximum input frequency 50 k Hz
■ Counter with 2 separate totalizers and a common
■
■
■
■
■
■
input (INPA)
Reset on panel or external with inhibition option
Supply: 10 ➞ 30 Vc
Easy to program
Scaling factor
Decimal point
Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24L - 2514
Functions
Counter with 2 separate totalizers and a common input
Code
87623573
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 5 screw terminals at rear of casing
Terminal capacity
Fixed using bracket
Degree of protection front face
Data memory
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Functions
Display
Height digits (mm)
Input characteristics
Inputs
Low level
High level
Cyclical ratio
Polarity
Minimum impulse duration for reset
Frequency of filtered input
Input impedance (kΩ)
Impulse counter (Partial - Totalizer)
Display details
Display
Elimination of non-significant zeros
Counting input mode
Input INPA
Reset input (terminal 5)
1
44
10 ➞ 30 Vc max 55 mA with protection against polarity reversal
✓
1.5 mm2
✓
IP 65
EEPROM
-20 ➞ +55
-25 ➞ +70
According to EN 61010-1: 2000 V / 50 Hz / 1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Counter with 2 separate totalizers and a common input
6-digit LED
8
1 counter input (INPA), 1 reset input
0 ➞ 0.2 x Ub Vc
0.6 x Ub ➞ 30 Vc
Any (maximum frequency given for a cyclical ratio = 1/1)
Schmitt trigger input
NPN or PNP for all inputs (programming)
5 ms
Filter active: 30 Hz
Filter disabled: maximum frequency (programming)
Appr. 5
0 ➞ 999 999
When the buttons are pressed, the counter displays the following values:
Total 1
Total 2
✓
INPA input counting
Dynamic
Dynamic Reset input connected in parallel with the red SET/RESET button
www.crouzet-control.com
Reset to zero - Panel
Remise à zéro - Externe (borne 5)
Scale factor
Scaling factor
Decimal point
If not locked during programming
If not locked during programming
1 ➞ 99.9999 (separate for A and B)
1 ➞ 99.9999 (separate for A and B)
0
0.0
0.00
0.000
50 k Hz
Maximum counting frequency
Dimensions (mm)
CTR24L - 2514
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24L
2
22x45
19,3
4
6,5
59
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
Connections
1
2
3
4
5
1 Supply: 10 ➞ 30 Vc
2 Supply: GND (0 V c )
3 INPA
4 NC
5 SET/RESET
www.crouzet-control.com
245
Applications
Programming diagram
2514
Count frequency:
DC power supply
Input level
typ. low level
typ. high level
Fmax*
tot.tot
CTR24L
InPol
FiltEr
PnP
nPn
oFF
on
24V
12V
Standard
2.5V
2.0V
22.0V
10V
kHz
kHz
60
20
Filter on 30Hz – off Fmax
Counter 1
Facto1
01.0000
99.9999
01.0000
99.9999
Multiplying factor
diVto1
Dividing factor
FActo2
0.0
0.00
ELrES
MAnrE
MAnEl
norES
Decimal point
reSnn1
01.0000
99.9999
01.0000
99.9999
Multiplying factor
diVto2
Dividing factor
0
dPto1
Counter 2
dPto2
0.000
0
0.0
0.00
ELrES
MAnrE
MAnEl
norES
Decimal point
reSnn2
0.000
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
ManEl: manual reset red Key and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
EndPro
SELECTION OF THE DISPLAYED VALUE
CTR24L
total1
Counter 1 (partial)
total2
Counter 2 (total)
Pressing the right key
displays successively the
following varius values
3
46
www.crouzet-control.com
Crouzet Control,
Technology and expertise,
behind every project
• Local support for all industrial projects.
• A multi-skilled team.
• A sales presence in over 40 countries.
• A Premium offer designed to ensure the excellence of products and services.
• Eco-design integrated in Crouzet's Offer Creation Process.
• Certifications: ISO 9001, ISO 14001, OHSAS 18001.
• Products which comply with international standards (UL, CSA, EC).
• A dynamic R&D department.
In addition to this catalogue, the www.crouzet-control.com
website offers the latest tools, available as free downloads,
including M3 Soft software, technical data sheets for each
product and installation manuals.
To order:
Customer Service
Crouzet Control
Tel.: +33 (0) 475 802 102
customer.relation@crouzet.com
www.crouzet-control.com
47
Electronic multifunction counters without preselection
➜ "DUO" multifunction counter - LED 24 x 48 - CTR24L
■ High brightness display: 6-digit LED, height 8 mm
■ Maximum input frequency 50 kHz (in tot.tot function)
■ Programmable dual functions: Counter + Tachometer/
■
■
■
■
■
■
■
■
Counter + Counter/Counter + Chronometer/
Chronometer + Chronometer
Reset on panel or external with inhibition option
Supply: 10 ➞ 30 Vc
Easy to program
Scaling factor (Counter - Tachometer)
Decimal point (Counter - Tachometer - Chronometer)
Timing range 0.001 s ➞ 999.999 hrs (Chronometer)
Impulses or time measured in hrs/min/sec and in real
time (Chronometer)
Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24L - 2515
Functions
DUO counter: Counter + Tachometer/Counter + Counter/Counter + Chronometer/Chronometer
+ Chronometer
Code
87623574
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 5 screw terminals at rear of casing
Connection capacity
Fixed using bracket
Degree of protection front face
Data memory
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Functions
Display
Height digits (mm)
Input characteristics
Inputs
Low level
High level
Cyclical ratio
Polarity
Minimum impulse duration for reset
Frequency of filtered input
Input impedance (kΩ)
Impulse counter
Display details
Elimination of non-significant zeros
Counting input modes
Input INPA
1
48
10 ➞ 30 Vc max 55 mA with protection against polarity reversal
✓
1.5 mm2
✓
IP 65
EEPROM
-20 ➞ +55
-25 ➞ +70
According to EN 61010-1: 2000 V / 50 Hz / 1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus - CE
50
Counter + Tachometer/Counter + Counter/Counter + Chronometer/
Chronometer + Chronometer
6-digit LED
8
2 counter inputs, 1 reset input
0 ➞ 0.2 x Ub Vc
0.6 x Ub ➞ 30 Vc
Any (maximum frequency given for a cyclical ratio = 1/1)
Schmitt trigger input
NPN or PNP for all inputs (programming)
5 ms
Filter active: 30 Hz
Filter disabled: maximum frequency (programming)
Appr. 5
0 ➞ 999 999
✓
INPA input counting
Dynamic (uses the same INPA input as the counter)
www.crouzet-control.com
Reset input (terminal 5)
Reset to zero - Panel
Reset to zero - External (terminal 5)
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Tachometer
Display details
Elimination of non-significant zeros
Conversion time
Input INPA
Accuracy
Measurement principle
Scale factor
Scaling factor
Decimal point
Maximum counting frequency
Chronometer
Display details
Elimination of non-significant zeros
Functions
Input INPA
Input INPB
Reset input (terminal 5)
Rest to zero - External (terminal 5)
Reset to zero - Panel
Accuracy
Decimal point
Time ranges
Maximum counting frequency
www.crouzet-control.com
Dynamic Reset input connected in parallel with the red SET/RESET button
Sets the counter to the defined preset value
If not locked during programming
If not locked during programming
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
50 kHz
0 ➞ 999 999
✓
1/s or 1/min
Dynamic (uses the same INPA input as the counter)
< 38 Hz: measurement of period duration
> 38 Hz: measurement of duration time base = 26.3 ms
< 0.1%
1 ➞ 99.9999
1 ➞ 99.9999
0
0.0
0.00
0.000
35 kHz
0.001 s ➞ 999 999 h
✓
In tot.tr function:
GatE.Lo ➞ Time measurement if INPB is not active
GatE.hi ➞ Time measurement if INPB is active
Inb.Inb ➞ Time measurement on/off via the INPB edge
In tr.tr function:
IGatE.Lo ➞ Time measurement if INPB is not active
GatE.hi ➞ Time measurement if INPB is active
Inb.Inb ➞ Time measurement on/off via the INPB edge
InA.Inb ➞ Measurement on via the INPA edge, measurement off via the
INPB edge
Start/Stop or Gate (depends on the input mode chosen)
Start/Stop or Gate (depends on the input mode chosen)
Dynamic Reset input connected in parallel with the red SET/RESET button
Sets the counter to the defined preset value
If not locked during programming
If not locked during programming
< 50
0
0.0
0.00
0.000
0.001 s ➞ 999 999 s
0.001 min ➞ 99 999 min
0.001 h ➞ 999 999 h
00 h 00 min 01 s ➞ 99 h 59 min 59 s
40 kHz
249
Dimensions (mm)
CTR24L - 2515
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24L
2
22x45
19,3
4
6,5
59
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
Connections
1
2
3
4
5
1 Supply: 10 ➞ 30 Vc
2 Supply: GND (0 Vc )
3 INPA
4 INPB
5 SET/RESET
3
50
www.crouzet-control.com
Applications
Programming diagram
2515
CTR24L
ModE
tot.tAc
tot.tot
InPol
PnP
nPn
FiltEr
oFF
on
InPol
PnP
nPn
FiltEr
oFF
on
Filter on 30Hz – off Fmax
Fac.tot
01.0000
InPol
FiltEr
Fac.tot
Fac.tot
01.0000
99.9999
Multiplying factor
01.0000
99.9999
Dividing factor
dP.tot
0
0.0
Decimal point
rES.tot
0.00
0.000
ELrES
MAnrE
MAnEl
norES
diV.tot
dP.tot
99.9999
Multiplying factor
diV.tac
01.0000
dP.tAt
rES.tot
ELrES
MAnrE
MAnEl
norES
rES.nn2
ELrES
MAnrE
MAnEl
norES
0.0
01.0000
StArt
on
Inb.Inb
InA.Inb
GatE.Lo
GatE.hI
GatE.Lo: Counting while INPB is inactive
GatE.hi: Counting while INPB is active
Inb.Inb: Count Start/Stop whit INPB edge
InA.Inb: Count Start whit INPA edge,
99.9999
count Stop with INPB edge
0.0
0.00
0.000
tMode
hour
h.Min.s
SEC
MIn
ELrES
MAnrE
Time units:
MAnEl
norES
h.m.s (decimal point setting is ignored)
s/h/min (accurancy depending on position
of the decimal point)
StArt
dP
Inb.Inb
GatE.Lo
GatE.hI
GatE.Lo: Counting while INPB is inactive
GatE.hi: Counting while INPB is active
Inb.Inb: Count Start/Stop whit INPB edge
tMode
hour
h.Min.s
SEC
MIn
Time units:
of the decimal point)
h.m.s (decimal point setting is ignored)
0.000
dP.tm
MIn-1
rES.t
rESetm1
0.0
0.00
0.000
ELrES
MAnrE
MAnEl
norES
ManEl: manual reset red Key
and electrical reset
norES: no reset
ElrES: only electrical reset
rESetm2
ELrES
MAnrE
MAnEl
norES
ManEl: manual reset red Key
0
0.0
0
Decimal point
s/h/min (accurancy depending on position
SEC-1: Value conversion and display in 1/s
Min-1: Value conversion and display in 1/m
oFF
0
Decimal point
SEC-1
99.9999
01.0000
nPn
and electrical reset
EndPro
0.00
FiltEr
PnP
Filter on 30Hz – off Fmax
norES: no reset
ElrES: only electrical reset
ManEl: manual reset red Key
and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
on
InPol
ManEl: manual reset red Key
0
Decimal point
diSPn
0.000
and electrical reset
norES: no reset
ElrES: only electrical reset
99.9999
Dividing factor
0.00
oFF
Decimal point
ManEl: manual reset red Key
and electrical reset
norES: no reset
ElrES: only electrical reset
01.0000
0.0
Decimal point
rES.nn1
dP.tot
0
nPn
Dividing factor
99.9999
Dividing factor
ManEl: manual reset red Key
FActAc
01.0000
PnP
Multiplying factor
diV.tot
diV.tot
tr.tr
Filter on 30Hz – off Fmax
Filter on 30Hz – off Fmax
99.9999
Multiplying factor
tot.tr
0.00
and electrical reset
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
0.000
ELrES
MAnrE
MAnEl
norES
EndPro
ManEl: manual reset red Key
Wait0
and electrical reset
00.1
norES: no reset
ElrES: only electrical reset
MAnrE: manual reset
99.9
Max time to wait 00.1…..99.9s
EndPro
INPA count and frequency input
INPA for count1 and count 2
Decimal point and scale factor
are equal for the two counter
total1
total1
CTR24L
tachO
Pressing the right key
displays successively the
following varius values
www.crouzet-control.com
CTR24L
Pressing the right key
displays successively the
following varius values
total2
EndPro
INPA input for count
INPB input time count
INPA input 2 time counter
INPB input 2 time counter
The two times counters work in parallel
and they have the same bases time
total
CTR24L
Pressing the right key
displays successively the
following varius values
time
time1
CTR24L
time
Pressing the right key
displays successively the
following varius values
451
Electronic counters without preselection
➜ Hour counters without preselection - LCD 24 x 48 - CTR24
■ Display: 8 digits LCD, 8 mm height
■ Built-in module for voltage inputs 10 ➞ 260 Va
(2224-2324)
■ 4 timing ranges: 99.999.99 hrs - 99.999.59 hrs ■
■
■
■
999.999.9 s - 9.999 hrs 59 min 59 s
Powered by a lithium battery, service life 8 years
Reset on panel or external with inhibition option
Backlit model (2323-2333-2324)
Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24 non-backlit model
CTR24 model with orange
backlighting
Type
2223
2233
2224
2323
2333
2324
Functions
Hour counter, solid state input PNP
Hour counter, solid state input NPN
Hour counter, voltage input
Hour counter, solid state input PNP
Hour counter, solid state input NPN
Hour counter, voltage input
Code
87622161
87622162
87622170
87622181
87622182
87622190
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 8 screw terminals at rear of casing
Connection capacity
Fixed using bracket
Degree of protection front face
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Function
Display
Height digits (mm)
Time ranges
Time base: Crystal controlled (Accuracy ± 100)
Input 2223-2323
One start/stop input by volt-free contact or NPN/PNP open-collector
transistor (terminals 2-6)
Low level
High level
Min time closed
Input impedance
Input 2233-2333
One start/stop input by volt-free contact or NPN/PNP open-collector
transistor (terminals 2-6)
Low level
High level
Minimum time closed
Input impedance
1
52
Backlighting: 24 Vc ± 20% 50 mA
✓
1.5 mm2
✓
IP 65
-10 ➞ +60
-20 ➞ +70
According to EN 610110-1: 2000 V / 50 Hz / 1 min.
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Hour counter
8-digit LCD
8
0 ➞ 99 999.99 h
0 ➞ 99 999.59 h
0 ➞ 9 999 999.9 s
0 ➞ 9 999 h 59 min 59 s
✓
✓
0 ➞ 0.7 Vc
4 ➞ 30 Vc PNP
> 100 ms
100 kΩ PNP
✓
0 ➞ 0.7 Vc
3 ➞ 30 Vc
> 100 ms
1 MΩ
www.crouzet-control.com
Reset - External 2223-2323 & 2233-2333
Volt-free contact or open collector (terminals 3-6)
Minimum time closed
Input 2224-2324
One start/stop input Two voltage levels (terminals 3-6)
Voltage - Terminals 1-2
Input impedance
Minimum pulse time c
Minimum pulse time a
Low level
High level
Reset - External 2224-2324
Voltage - Terminals 2-3
Minimum pulse time
Low level
High level
Reset to zero - Panel
Reset via
✓
50 ms
✓
10 ➞ 260 Vz
160 KΩ
100 ms
100 ms
0 ➞ 2 Vz
10 ➞ 260 Vz
✓
16 ms
0 ➞ 2 Vz
10 ➞ 260 Vz
Inhibited: Terminals 4-6 not connected
Active: Terminals 4-6 connected
Supply
1 lithium battery - Life (years)
8
Dimensions (mm)
CTR24
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24
2
22x45
19,3
2,8
47,7
3
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
www.crouzet-control.com
253
Connections
2223-2323
2223-2323
2223-2323
2
2
6
6
1 2 3 4 5 6 7 8
30 Vdc
1 2 3 4 5 6 7
8
9999h59m 59s
9999999.9s
99999h59m
99999.99h
1 NC
2 Start/Stop input
3 Reset input 100 ms
4 Enable panel reset
Start/Stop input
Transistor PNP
Start/Stop input PNP
5 Mode 1 (Time selection)
6 0 V common/ (BL- only 23xx)
7 Mode 2 (Time selection)
8 Backlighting option + 24 Vc (only 2323)
2233-2333
2233-2333
2233-2333
2-3
3-2
6
6
Start/Stop or reset input NPN - Transistor
Start/Stop or reset input PNP - Transistor
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
9999h59m 59s
9999999.9s
99999h59m
99999.99h
1 NC
2 Start/Stop input
3 Reset input 100 ms
4 Enable panel reset
5 Mode 1 (Time selection)
6 0 V common/ (BL- only 23xx)
7 Mode 2 (Time selection)
8 Backlighting option + (only 2333)
3
54
www.crouzet-control.com
2233-2333
2234-2324
2234-2324
3-2
1-3
10-240V~/
2
6
1 2 3 4 5 6 7 8
10260 10260
Vac/dc Vac/dc
1 2 3 4 5 6 7 8
9999h59m 59s
9999999.9s
99999h59m
99999.99h
Start/Stop or reset input NPN - Transistor
Start/Stop or reset input - Voltage
1 Start/Stop input
2 AC/DC common
3 Reset input
4 Enable panel reset
5 Mode 1 (Time selection)
6 0 V common/ (BL- only 23xx)
7 Mode 2 (Time selection)
8 Backlighting option + 24 Vc (only 2324)
2234-2324
2234-2324
1-3
10-240V~/
2
+
2234-2324
+
PNP
1-3
OV
Start/Stop or reset input - Contact
supplied with power
2234-2324
30 V
10-260V
10-260V
2
1-3
NPN
OV
Start/Stop or reset input PNP
Transistor or 3-wire PNP proximity
sensor for leakage current
detector < 1 mA
2
Start/Stop or reset input NPN
Transistor or 3-wire NPN proximity
sensor for leakage current
detector < 1 mA
2234-2324
max
30 V
1-3
max
1-3
2
OV
Start/Stop or reset input: 2-wire
proximity sensor R=470 Ω/2 W for 2-
wire leakage current detector ≤ 1 mA
www.crouzet-control.com
OV
2
Start/Stop or reset input: 2-wire
proximity sensor R=470 Ω/2 W for 2-
wire leakage current detector ≤ 1 mA
4 55
Electronic counters without preselection
➜ Totalizers without preselection - LCD 24 x 48 - CTR24
■ Display: 8-digit LCD, height 8 mm
■ Powered by a lithium battery
■ Counter inputs: solid state (4-30 Vc ) or voltage
(10 ➞ 260 Va )
■ Reset on panel or external with inhibition option
■ Backlit model (2341-2351-2342)
■ Counting directions can be selected with input (22412341/2251-2351)
■ Accessories for 50 x 25 mm cut-out
Part numbers
Type
CTR24 non-backlit model
CTR24 model with orange
backlighting
Type
2241
2251
2242
2341
2351
2342
Functions
Solid state input, lithium battery PNP/NPN
Solid state input, lithium battery NPN/NPN
Voltage input, lithium battery
Solid state input, lithium battery PNP/NPN
Solid state input, lithium battery NPN/NPN
Voltage input, lithium battery
Code
87622061
87622062
87622070
87622081
87622082
87622090
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
DIN rail adaptor
Clip-fixing kit (supplied with the product)
Code
26546843
26546844
26546840
26546848
General characteristics
Environmental characteristics
Consumption
Connection by 8 screw terminals at rear of casing
Connection capacity
Fixed using bracket
Degree of protection front face
Temperature limits use (°C)
Temperature limits stored (°C)
Breakdown voltage
Conformity to standards
Altitude
Certifications
Weight (g)
Operating characteristics
Function
Display
Height digits (mm)
Counting capacity
Inputs 2241-2341
1 slow counting input for contact closure on NPN open-collector transistor
input (terminals 2-6)
1 input for high speed counting signal from voltage level (terminals 1-6)
Low level
High level
High-speed counting
Input impedance
Inputs 2251-2351
1 slow counting input for contact closure on NPN open-collector transistor
input (terminals 2-6)
1 input for high speed counting signal from voltage level (terminals 1-6)
Low level
High level
High-speed counting
Input impedance
1
56
Backlighting: 24 Vc ± 20% 50 mA
✓
1.5 mm2
✓
IP 65
-10 ➞ +60
-20 ➞ +70
According to EN 61010-1: 2000 V / 50 Hz / 1 min
EN 61000-6-2 - EN 55011 class B
2000 m
UL - cULus (pending) - CE
50
Impulse counter
8-digit LCD
8
-9.999.999 ➞ 99.999.999 with elimination of zeros
✓
4 ➞ 30 Vc
0 ➞ 0.7 Vc
4 ➞ 30 Vc PNP
12 KHz max.
42 µs PNP
100 KΩ PNP
✓
3 ➞ 30 Vc
0 ➞ 0.7 Vc
3 ➞ 30 Vc
7 KHz max.
70 µs NPN
1 MΩ
www.crouzet-control.com
Reset - External 2241-2341 & 2251-2351
Volt-free contact or open collector (terminals 3-6)
Inputs 2242-2342
1 input for slow counting 2 voltage levels
Voltage - Terminals 1-2
Input impedance (kΩ)
Slow counting
Minimum pulse time
Low level
High level
Reset - External 2242-2342
Voltage - Terminals 2-3
Minimum pulse time
Low level
High level
Reset to zero - Panel
Reset via
✓
✓
10 ➞ 260 Vz
160
30 Hz
16 ms
0 ➞ 2 Vz
10 ➞ 260 Vz
✓
16 ms
0 ➞ 2 Vz
10 ➞ 260 Vz
Inhibited: Terminals 4-6 not connected
Active: Terminals 4-6 connected
Supply
1 lithium battery - Life (years)
8
Dimensions (mm)
CTR24
Fixing strip with clip-on yoke
48
Panel cut-out
1
+0,6
24
22,2 - 0
+0,3
45
CTR24
2
22x45
19,3
2,8
47,7
3
1 Seal
2 Fixing yoke
4 appliances
26546843 - Adaptor for 50 x 25 mm cut-out Fixed with screws
+ 0,6
30
53
56
25X50
28
25X50
32
40
20 22,2
+ 0,3
45
26546844 - Adaptor for 50 x 25 mm cut-out Fixed with clips
1
4
1
4
Accessory supplied with the counter
26546840 - DIN rail adaptor
101
50,4 x 25,4
75
83
45
45
70
www.crouzet-control.com
257
Connections
2241-2341
2241-2341
2241-2341
4-30V
+
4-30V
36
+
51
PNP
1 2 3 4 5 6 7 8
1
OV
6
30 Vdc -12 KHz
1 2 3 4 5 6 7 8
PNP fast count input - Voltage
1 Fast count
2 Slow count
3 Reset input 12 ms
PNP fast count input Transistor or 3-wire
PNP proximity sensor (for leakage
current detector ≤ 1 mA)
4 Enable panel reset
5 Mode count direction
6 0 V common/ (BL- only 23xx)
7 Backlighting option (only 2341)
8 Backlighting option + 24 Vc (only 2341)
2241-2341
2241-2341
4-30V
2241-2341
4-30V
1
2-3
1
6
6
OV
2-wire proximity sensor fast count input
2241-2341
6
OV
2-wire proximity sensor fast count input
2241-2341
3-2
6
Slow count input (2) or reset input (3)
2251-2351
3-2
6
1 2 3 4 5 6 7 8
7KHz
30Hz
1 2 3 4 5 6 7 8
Slow count input (2) or reset input (3)
Slow count input (2) or reset input (3) Contact not supplied with power
1 Fast count
2 Slow count
3 Reset input 12 ms
4 Enable panel reset
5 Mode count direction
6 0 V common/ (BL- only 23xx)
7 Backlighting option + (only 2351)
8 Backlighting option + 24 Vc (only 2351)
3
58
www.crouzet-control.com
2251-2351
2251-2351
2251-2351
4-30V
1
1-3
+
6
1
NPN
2
6
OV
Fast count input NPN - Voltage
2251-2351
Fast count input NPN Transistor or 3-wire
PNP proximity sensor (for leakage current
detector ≤ 1 mA)
2251-2351
3-2
6
6
2242-2342
2-wire proximity sensor fast count input
2251-2351
2-3
Slow count input (2) or reset input (3)
OV
3-2
6
Slow count input (2) or reset input (3)
2242-2342
Slow count input (2) or reset input (3)
Contact not supplied with power
2242-2342
1-3
10-240V~/
2
1-3
10-240V~/
2
1 2 3 4 5 6 7 8
30Hz
10260 10260
Vac/dc Vac/dc
1 2 3 4 5 6 7 8
Counter or reset input - Voltage
1 Fast count
2 AC/DC common
Counter or reset input Contact supplied with power
3 Reset input 12 ms
4 Enable panel reset
5 count direction
6 0 V common/ (BL- only 23xx)
7 Backlighting option - (only 2342)
8 Backlighting option + 24 Vc (only 2342)
2242-2342
+
2242-2342
2242-2342
10-260V
10-260V
+
PNP
1-3
OV
2
Counter or reset input PNP Transistor or
3-wire PNP proximity sensor (for leakage
current detector < 1 mA)
www.crouzet-control.com
30 V
max
1-3
1-3
NPN
2
OV
2
Counter or reset input NPN Transistor or
3-wire PNP proximity sensor (for leakage
current detector < 1 mA)
OV
Start/Stop or reset input: 2-wire proximity
sensor R=470 Ω/2 W for 2-wire leakage
current detector ≤ 1 mA
459
Electromechanical hour counters
➜ Hour counters 48 X 48 - CHM48
AC: capacity 100.000 hrs (99.999.99 hrs)
DC: capacity 1.000.000 hrs (999.999.99 hrs)
Operation indicator
Panel mounted
DIN rail mounted with connector base (accessory part
number: 26546845)
■ IP52
■ Highly resistant to shocks and impacts
■ Excellent visibility due to the large digit size
■
■
■
■
■
Part numbers
Type
CHM48
Operating frequency (Hz)
50
50
50
50
50
60
60
60
60
60
c
c
c
Voltages
20 ➞ 30 Va
42 ➞ 48 Va
100 ➞ 130 Va
360 ➞ 440 Va
187 ➞ 264 Va
100 ➞ 130 Va
187 ➞ 264 Va
360 ➞ 440 Va
20 ➞ 30 Va
42 ➞ 48 Va
10 ➞ 30 Vc
36 ➞ 80 Vc
100 ➞ 130 Vc
Code
99772710
99772711
99772712
99772713
99772714
99772715
99772716
99772717
99772718
99772719
99772810
99772811
99772812
Accessories
Description
Adaptor for 72 x 72 mm cut-out
Adaptor for 55 x 55 mm cut-out
DIN rail adaptor
Code
26546842
26546846
26546845
General characteristics
General characteristics
Counting capacity
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Counting input mode
Operation indicator
Degree of protection front face
Mounting
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connections (panel mounted version)
Connections (DIN rail mounted version)
Connection capacity
Consumption
Vibration resistance
Test voltage for AC models
Weight (g)
1
60
Va : 99 999.99
Vc : 999.999.99
Not included
1/100 h
4
White on a black background
Red on a black background
Va : frequency + 30 ms
Vc : < 0.003% (24 hrs)
Addition
Va : rotating red lines
Vc : 1/100 hr 1 digit in 36 s
IP52
Any
-15 ➞ +50
-40 ➞ +80
UL (pending)
Screw terminals - 6.35 mm Faston connectors
Screw terminals with accessory 26 546 845
2.5 mm2
Vc : 10 ➞ 30 approx. 500 mW/100 ➞ 130 approx. 750 mW/
Va 50 Hz: 20 ➞ 30 approx. 0.3 VA/42 ➞ 48 approx. 0.25 VA/100 ➞ 130
approx. 0.6 VA/187 ➞ 264 approx. 1.2 VA/360 ➞ 440 approx. 1.65 VA
50 m/s2 (10-500 Hz) IEC 68-2-6
2 000 Va 50 Hz
50
www.crouzet-control.com
Dimensions (mm)
Panel mounted
Panel cut-out
26546842 - Adaptor for 72 x 72 mm cut-out
7,4
48
50
72
45,4
Ø
45 +0.6
0
h
45
max.9
7
+0.6
45 0
1
28
1 Screw terminals
26546846 - Adaptor for 55 x 55 mm cut-out
26546845 - DIN rail mounted
0
7,4 ±0,1
19
48,5
www.crouzet-control.com
5
61,5
32
48,1
0
38
48
6 ±0,1
45,4 +0,2
55 -0,2
41,1
261
Electromechanical hour counters
➜ Hour counters 24 X 48 - CHM24
■
■
■
■
■
■
■
■
Va : capacity 100.000 hrs (99.999.99 hrs)
Vc : capacity 1.000.000 hrs (999.999.99 hrs)
Operation indicator
Panel mounted
IP65 (with accessory 26546847)
Highly resistant to shocks and impacts
Compact size
Excellent visibility due to the large digit size
Part numbers
Type
CHM24
Operating frequency (Hz)
50
50
50
60
60
60
c
Voltages
20 ➞ 30 Va
100 ➞ 130 Va
187 ➞ 264 Va
100 ➞ 130 Va
187 ➞ 264 Va
20 ➞ 30 Va
10 ➞ 30 Vc
Code
99782710
99782712
99782714
99782715
99782716
99782718
99782810
Accessories
Description
Set of seals
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips
Code
26546847
26546843
26546844
General characteristics
General characteristics
Counting capacity
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Counting input mode
Operation indicator
Protection rating
Mounting position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connections (panel mounted version)
Tightening torque (Nm)
Connection capacity
Consumption
Vibration resistance
Test voltage for AC models
Weight (g)
1
62
Va : 99.999.99
Vc : 999.999.99
Not included
1/100 h
4
White on a black background
Red on a black background
Va : frequency + 30 ms
Vc : < 0.003% (24 hrs)
Addition
Va : rotating red lines/DC: 1/100 hr 1 digit in 36 s
IP52 or IP65 with accessory (26546847)
Any
-10 ➞ +50
-40 ➞ +80
CE - UL (pending)
Screw terminals - 6.35 mm Faston connectors
0.8
2.5 mm2
Vc : 10 ➞ 30 approx. 500 mW/100 ➞ 130 approx. 750 mW/
Va 50 Hz: 20 ➞ 30 approx. 0.3 VA/100 ➞ 130 approx. 0.6 VA/187 ➞ 264
approx. 1.2 VA
50 m/s2 (10-500Hz) IEC 68-2-6
2 000 Va 50 Hz
50
www.crouzet-control.com
Dimensions (mm)
26546843 - Adaptor for cut-out
53
56
+0,6
28
25X50
32
40
22,2 - 0
+0,3
45
26546844 - Adaptor for cut-out
25X50
Panel cut-out
1
4
1
4
CHM24
max.19
22 x 45
24
48
3
48,5
www.crouzet-control.com
263
Electromechanical hour counters
➜ Hour counters 15 X 32 - CHM15
■
■
■
■
■
■
■
Capacity 100.000 hrs (99.999.99 hrs)
Wide range of voltages: 4.5 ➞ 35 Vc
Panel mounted
IP65
Highly resistant to shocks and impacts
Compact size
Excellent visibility thanks to the large digit size
Part numbers
Type
CHM15
Operating frequency (Hz)
c
Voltages
4.5 ➞ 35 Vc
Code
99792810
General characteristics
General characteristics
Counting capacity
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Counting input mode
Degree of protection front face
Mounting position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connections (panel mounted version)
Consumption
99.999.99
Not included
1/100 h
4
White on a black background
Red on a black background
Vc : < 0.003% (24 hrs, 25°C)
Addition
IP65
Horizontal readout of digits
-10 ➞ +60
-40 ➞ +80
CE - UL (pending)
Flying leads: 150 mm
5 Vc approx. 82 mW/12 Vc approx. 135 mW/24 Vc approx. 135 mW/
max 170 mW
50 m/s2 (10-500 Hz) IEC 68-2-6
2 000 Va 50 Hz
20
Vibration resistance
Test voltage for AC models
Weight (g)
Dimensions (mm)
Panel cut-out
+0,3
13 - 0
+0,5
30
CHM15
13 x 29.9
1,1
15
32
2
max.3
150
1
64
32,7
www.crouzet-control.com
Electromechanical hour counters
➜ DIN rail mounting hour counters - CHMDR
■
■
■
■
■
■
■
■
Width equivalent to 2 modules
Capacity 100.000 hrs (99.999.99 hrs)
Extended temperature range: -10 ➞ +70°C (a version)
DIN rail mounted according to EN 50022
IP65 on panel
Highly resistant to shocks and impacts
Colour: RAL 7035 grey
Screw terminals
Part numbers
Type
CHMDR
Operating frequency (Hz)
50
50
50
c
Voltages
24 Va
115 Va
230 Va
10 ➞ 27 Vc
Code
99793710
99793712
99793714
99793810
Accessories
General characteristics
General characteristics
Counting capacity
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Counting input mode
Degree of protection front face
Tolerance
Temperature limits use (°C)
99.999.99
Not included
1/100 h
3.5
White on a black background
Black on a white background
Va /Vc : < 0.01% (24 hrs)
Addition
IP 65
Va ± 10%
Va : -10 ➞ +70
Vc : -10 ➞ +50
-40 ➞ +80
CE
Screw terminals
Va : approx. 2.5 VA
Vc : approx. 1 W
1G (10-500 Hz)
2 000 Va 50 Hz
60
Temperature limits stored (°C)
Certifications
Connection
Consumption
Vibration resistance
Test voltage for AC models
Weight (g)
Dimensions (mm)
CHMDR
h
1
www.crouzet-control.com
45
60
44
90
6
36
65
Dual-function electromechanical counters
➜ Dual-function counter (hour counter and watt-hour meter) 48 x 48 - CEM48
■
■
■
■
■
■
Dual-function counter (hour counter and watt-hour meter)
Capacity 100.000 hrs (99.999.99 hrs)
Remote readout via SO output
Panel mounted
IP 65
Excellent visibility due to the large digit size
Part numbers
Type
CEM48
Designation
Single-phase (max. 16 A)
Single-phase (max. 16 A)
Operating frequency (Hz)
50 / 60
50 / 60
Voltages
115 Va
230 Va
Code
99780712
99780714
Accessories
Description
Adaptor for 72 x 72 mm cut-out
Adaptor for 55 x 55 mm cut-out
DIN rail adaptor
Code
26546842
26546846
26546841
General characteristics
General characteristics
Counting capacity
Display by LED
99.999.9 hrs/99.999.9 kWh
LED backlight: the counter is powered up
LED flashing: the energy is being measured
Not included
1/10 h
4
White on a black background
Red on a black background
Hour counter: ± 2%
Watt-hour meter: Class B (1%)
Imax: 16 A
Current limits between 20 mA and 16 A
Use for current > 20 mA
IP65
Any
- 20 ➞ +55
- 25 ➞ +65
CE
Screw terminals
2.5 mm2
Watt-hour meter: 10 impulses/hr, 5 ➞ 30 Vc , Imax: 20 mA
Hour counter: 1000 impulses/kWh, 5 ➞ 30 Vc , Imax: 20 mA
EN 50470-1, EN 50470-3
2 000 Va 50 Hz
83
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Current
Degree of protection front face
Mounting
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Connection capacity
Output signal
Standards
Test voltage for AC models
Weight (g)
Dimensions (mm)
Panel mounted
Panel cut-out
26546842 - Adaptor for 72 x 72 mm cut-out
7,4
GND
72
45,4
50
1
48
Ø
48
L in
45 +0.6
0
SO kWh
L out
N
9
45
+0.6
45 0
1 9 max.
1
66
www.crouzet-control.com
26546846 - Adaptor for 55 x 55 mm cut-out
0
55 -0,2
0
48,1
45,4 +0,2
6 ±0,1
7,4 ±0,1
26546841 - DIN rail adaptor
145
41
50 +0,5
0
5,5
75
83
15
22
70
Connections
CEM48
LN
N
Lin
Lout
kWh
h
006695
006695
SO h
SO kWh
GND
www.crouzet-control.com
267
Dual-function electromechanical counters
➜ Dual-function counters (hour counter and impulse counter) 48 x 48 - CMM48
■ Dual-function counter (hour counter and impulse
■
■
■
■
■
■
■
counter)
Va : capacity 100.000 hrs (99.999.99 hrs)
Vc : capacity 1.000.000 hrs (999.999.99 hrs)
Operation indicator
Panel mounted
IP52
Highly resistant to shocks and impacts
Excellent visibility thanks to the large digit size
Part numbers
Type
CMM48
Operating frequency (Hz)
50
50
50
60
60
60
Vc
Voltages
20 ➞ 30 Va
Code
99779710
99779712
99779714
99779718
99779715
99779716
99779810
100 ➞ 130 Va
187 ➞ 264 Va
20 ➞ 30 Va
100 ➞ 130 Va
187 ➞ 264 Va
10 ➞ 30 Vc
Accessories
Description
Adaptor for 72 x 72 mm cut-out
Adaptor for 55 x 55 mm cut-out
Code
26546842
26546846
General characteristics
General characteristics
Counting capacity
Reset to zero
Read accuracy
Height digits (mm)
Colour of hour numbers
Colour of decimal digits
Accuracy
Counting input mode
Operation indicator
Degree of protection front face
Mounting position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connections (panel mounted version)
Connection capacity
Consumption
Vibration resistance
Test voltage for AC models
Weight (g)
1
68
Va : 99.999.99 hrs
Vc : 999.999.99 hrs
Not included
1/100 h
4
White on a black background
Red on a black background
Va : frequency + 30 ms
Vc : < 0.003% (24 hrs)
Addition
Va : rotating red lines
Vc : 1/100 hr 1 digit in 36 s
IP52
Any
-15 ➞ +50
-40 ➞ +80
CE - UL (pending)
Screw terminals - 6.35 mm Faston connectors
2.5 mm2
Vc : 10 ➞ 30 approx. 1 W
Va 50 Hz: 20 ➞ 30 approx. 0.53 VA
100 ➞ 130 approx. 1.43 VA/187 ➞ 264 approx. 3 VA
50 m/s2 (10-500 Hz) IEC 68-2-6
2 000 Va 50 Hz
65
www.crouzet-control.com
Dimensions (mm)
Panel mounted
Panel cut-out
26546842 - Adaptor for 72 x 72 mm cut-out
1,2
48
30
72
45,4
Ø
h
45 +0.6
0
50
7,4
45
8
+0.6
45 0
26546846 - Adaptor for 55 x 55 mm cut-out
0
0
48,1
6 ±0,1
45,4 +0,2
55 -0,2
7,4 ±0,1
www.crouzet-control.com
269
Electromechanical impulse counters
➜ Impulse counters 24 x 48 - CIM24
■ 5 or 6 digits, height of digits 4 mm
■ With or without manual reset
■ White digits on a black background
Part numbers
Type
Without
manual reset
With manual
reset
Number of digits
6
6
6
6
5
5
5
5
Operating frequency (Hz)
50 / 60
50 / 60
Vc
Vc
50 / 60
50 / 60
Vc
Vc
Voltages
230 Va
24 Va
24 Vc
12 Vc
230 Va
24 Va
24 Vc
12 Vc
Code
99777714
99777710
99777810
99777815
99777724
99777720
99777820
99777825
Accessories
Description
Adaptor for 50 x 25 mm cut-out - Fixed with screws
Adaptor for 50 x 25 mm cut-out - Fixed with clips (supplied with the product)
Adaptor for 48 x 48 mm cut-out
Code
26546843
26546844
26546849
General characteristics
General characteristics
Counting capacity
Height digits (mm)
Max. count rate
Min. count rate
Min pause time between 2 pulses
Max. pulse length (count coil)
Voltage variation
Consumption
Mechanical life count function (operations)
Test voltage according to standard IEC 255-5
Protection Housing
Degree of terminal protection
Environmental protection
Maintenance
Operating position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Mounting
Weight (g)
1
70
999.999 impulses without manual reset
99.999 impulses with manual reset
4
Va ➞ 10 impulses/s
Vc ➞ 10 impulses/s
Va ➞ 50 ms
Vc ➞ 50 ms
Va ➞ 50 ms
Vc ➞ 50 ms
Unlimited
12/24 Vc : ± 10%
Va : ± 10%
24 Va : 0.75 VA
230 Va : 1.5 VA
12/24 Vc : 0.5 W
> 50 x 106
U < 60 V: 500 V
U > 60 V: 2 000 V
IP40
IP00
Plated or stainless steel components
None
Any
- 10 ➞ +50
- 40 ➞ +80
CE
6.35 Faston connectors or screw terminals
With clip
65
www.crouzet-control.com
Dimensions (mm)
Panel cut-out
26546844 - Adaptor for 50 x 25 mm cut-out
53
40
25X50
28
22,2 - 0
25X50
56
32
+0,6
+0,3
45
26546843 - Adaptor for 50 x 25 mm cut-out
1
4
1
4
26546849 - Adaptor for 50 x 25 mm cut-out
48
11
24
22,2
45,2
8
9977771/81 - 6 digits
48
9977772/82 - 5 digits
1
53,8
4
24
24
48
4
49
1
www.crouzet-control.com
6
271
Electromechanical impulse counters
➜ Impulse counters - CIM 36 x 37
■ 5 or 6 digits, height of digits 4 mm
■ With or without manual reset
■ White digits on a black background
Part numbers
Type
Without
manual reset
With manual
reset
Number of digits
6
6
6
6
6
5
5
5
5
Operating frequency (Hz)
50 / 60
50 / 60
50 / 60
Vc
Vc
50 / 60
50 / 60
50 / 60
Vc
Voltages
230 Va
115 Va
24 Va
110 Vc
24 Vc
230 Va
115 Va
24 Va
24 Vc
Code
99776601
99776602
99776604
99776605
99776607
99776610
99776611
99776613
99776616
General characteristics
General characteristics
Counting capacity
Height digits (mm)
Max. count rate
Min. count rate
Min pause time between 2 pulses
Max. pulse length (count coil)
Voltage variation
Consumption
Mechanical life count function (operations)
Test voltage according to standard IEC 255-5
Protection Housing
Degree of terminal protection
Environmental protection
Maintenance
Operating position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Mounting
Weight (g)
1
72
999.999 impulses without manual reset
99.999 impulses with manual reset
4
Va ➞ 18 impulses/s
Vc ➞ 25 impulses/s
Va ➞ 28 ms
Vc ➞ 20 ms
Va ➞ 28 ms
Vc ➞ 20 ms
Unlimited
+ 10% / -15% Un
24 Va / 115 Va : 1.1 VA
230 Va : 2.1 VA
110 Vc : 1 W
24 Vc : 0.8 W
> 50 x 106
U < 60 V: 500 V
U > 60 V: 2 000 V
IP40
IP00
Plated or stainless steel components
None
Any
- 10 ➞ +60
- 40 ➞ +80
CE
6.35 Faston connectors or screw terminals
2 x 2.5 Ø screws - F90° on front face
50
www.crouzet-control.com
Dimensions (mm)
9977660 - Rear faces
Panel cut-out
9977660 - Rear faces
30
24
33,5
¯2,7
9977660 - 6 digits
8,5
49,3
20
6
23,5
30
36
37
2,5
Ø2,5
9977661 - 5 digits
8,5
54,1
20
6
23,5
30
36
37
2,5
2,5
6
www.crouzet-control.com
273
Electromechanical impulse counters
➜ Impulse counters - CIM 36 x 48
■ 5 or 6 digits, height of digits 4 mm
■ With or without manual reset
■ White digits on a black background
Part numbers
Type
Without
manual reset
With manual
reset
Number of digits
6
6
6
6
6
6
5
5
5
5
Operating frequency (Hz)
50 / 60
50 / 60
50 / 60
Vc
Vc
Vc
50 / 60
50 / 60
50 / 60
Vc
Voltages
230 Va
115 Va
24 Va
110 Vc
24 Vc
48 Vc
230 Va
115 Va
24 Va
24 Vc
Code
99776701
99776702
99776704
99776705
99776707
99776736
99776710
99776711
99776713
99776716
General characteristics
General characteristics
Counting capacity
Height digits (mm)
Max. count rate
Min. count rate
Min pause time between 2 pulses
Max. pulse length (count coil)
Voltage variation
Consumption
Mechanical life count function (operations)
Test voltage according to standard IEC 255-5
Protection Housing
Degree of terminal protection
Environmental protection
Maintenance
Operating position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Mounting
Weight (g)
1
74
999.999 impulses without manual reset
99.999 impulses with manual reset
4
Va ➞ 18 impulses/s
Vc ➞ 25 impulses/s
Va ➞ 28 ms
Vc ➞ 20 ms
Va ➞ 28 ms
Vc ➞ 20 ms
Unlimited
+ 10% / -15% Un
24 Va / 115 Va : 1.1 VA
230 Va : 2.1 VA
110 Vc : 1 W
48 Vc : 0.8 W
24 Vc : 0.8 W
> 50 x 106
U < 60 V: 500 V
U > 60 V: 2 000 V
IP40
IP00
Plated or stainless steel components
None
Any
-10 ➞ +60
-40 ➞ +80
CE
6.35 Faston connectors or screw terminals
2 x 2.5 Ø screws - F90° on front face
50
www.crouzet-control.com
Dimensions (mm)
9977670/3 - Rear faces
Panel cut-out
9977671 - Rear faces
30
24
44
Ø2,7
9977670/3 - 6 digits
8,5
49,3
20
23,5
6
30
36
48
2,5
Ø2,5
9977671 - 5 digits
8,5
54,1
Ø2,5
20
6
23,5
30
36
48
2,5
6
www.crouzet-control.com
275
Electromechanical impulse counters
➜ Impulse counters with built-in fixing clip - 15 x 32 - CIM15
■
■
■
■
■
■
7 digits, height of digits 4 mm
Without manual reset
White digits on a black background
Compact size
Built-in fixing clip
IP65 (panel only)
Part numbers
Type
Without manual reset
Operating frequency (Hz)
50 / 60
50 / 60
50 / 60
Vc
Vc
Vc
Voltages
24 Va
115 Va
230 Va
5 Vc
12 Vc
24 Vc
Code
99778710
99778712
99778714
99778805
99778806
99778810
General characteristics
*9.999.999
Counting capacity
Height digits (mm)
Max. count rate
Min. count rate
Min pause time between 2 pulses
Max. pulse length (count coil)
Voltage variation
Consumption
Mechanical life count function (operations)
Test voltage according to standard IEC 255-5
Protection Housing
Degree of terminal protection
Environmental protection
Maintenance
Operating position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Mounting
Weight (g)
1
76
9.999.999
4
Va ➞ 10 impulses/s
Vc ➞ 10 impulses/s (except for 99778810: up to 25 impulses/s)
Va ➞ 50 ms
Vc ➞ 50 ms
Va ➞ 50 ms
Vc ➞ 50 ms
Unlimited
Vc : ± -10%
Va : ± -10%
Va : 800 mVA
Vc : 50 mW
> 50 x 106
U < 60 V: 500 V
U > 60 V: 2 000 V
IP65 panel only
IP00
Plated or stainless steel components
None
Any
-10 ➞ +60
-40 ➞ +80
UL (pending) - CE
Flying leads
Built-in fixing clip
20
www.crouzet-control.com
Dimensions (mm)
Panel cut-out
+0,3
1
13 +0,5
30
1 R max: 0.5 mm
997787/8 - 7 digits
13 x 29.9
2
1,1
15
32
max.3
150
www.crouzet-control.com
32,7
277
Electromechanical impulse counters
➜ Screw-fixing impulse counters - CIM 24 x 48
■ 5 or 6 digits, height of digits 4 mm
■ With or without manual reset
■ White digits on a black background
Part numbers
Type
Without
manual reset
With manual
reset
Number of digits
6
6
6
6
6
5
5
5
5
Operating frequency (Hz)
50 / 60
50 / 60
50 / 60
Vc
Vc
50 / 60
50 / 60
50 / 60
Vc
Voltages
230 Va
115 Va
24 Va
110 Vc
24 Vc
230 Va
115 Va
24 Va
24 Vc
Code
99776901
99776902
99776904
99776905
99776907
99776921
99776922
99776924
99776927
General characteristics
General characteristics
Counting capacity
Height digits (mm)
Max. count rate
Min. count rate
Min pause time between 2 pulses
Max. pulse length (count coil)
Voltage variation
Consumption
Mechanical life count function (operations)
Test voltage according to standard IEC 255-5
Protection Housing
Degree of terminal protection
Environmental protection
Maintenance
Operating position
Temperature limits use (°C)
Temperature limits stored (°C)
Certifications
Connection
Mounting
Weight (g)
1
78
999.999 impulses without manual reset
99.999 impulses with manual reset
4
Va ➞ 18 impulses/s
Vc ➞ 25 impulses/s
Va ➞ 28 ms
Vc ➞ 20 ms
Va ➞ 28 ms
Vc ➞ 20 ms
Unlimited
+ 10% / -15% Un
24 Va / 115 Va : 1.1 VA
230 Va : 2.1 VA
110 Vc : 1 W
24 Vc : 0.8 W
50 x 106
U < 60 V: 500 V
U > 60 V: 2 000 V
IP40
IP00
Plated or stainless steel components
None
Any
-10 ➞ +60
-40 ➞ +80
CE
6.35 Faston connectors or screw terminals
2 M3 screws - F90° on front face
50
www.crouzet-control.com
Dimensions (mm)
9977690 - Rear faces
Panel cut-out
9977692 - Rear faces
41,5
23
37
M3
9977690 - 6 digits
48
8,5
41,5
Ø3,2
www.crouzet-control.com
20
6
22,5
24
49,3
3
2
79
EUROPE / MIDDLE EAST / AFRICA
CANADA
BELGIUM
SPAIN / PORTUGAL
CHINA
InnoVista Sensors™
1461 Lawrence Drive
Thousand Oaks, CA 91320
USA
Tel.: +1 (800) 677 5311
Fax: +1 (800) 677 3865
customer.service@us.crouzet.com
InnoVista Sensors™
Dieweg 3 B
1180 Uccle - BELGIQUE
Tel.: +32 (0) 2 462 07 30
Fax: +32 (0) 2 461 00 23
klantenservice@crouzet.com
InnoVista Sensors™
C/Lleó, 11-13 2º4ª
08911 Badalona - Barcelona
ESPAÑA
Tel.: +34 (93) 484 39 70
Fax: +34 (93) 484 39 73
atencionalcliente@crouzet.com
InnoVista Sensors™
11th floor, Chang Feng
International Tower,
89 Yunling Road (East),
Putuo District,
Shanghai 200 062 - CHINA
Tel.: +86 (21) 8025 7166
Fax: +86 (21) 6107 1771
china@crouzet.com
MEXICO
FRANCE
SWITZERLAND
INDIA
InnoVista Sensors™
Calzada Zavaleta 2505-C
Santa Cruz Buenavista
Puebla, 72150 - MEXICO
Tel.: +52 (222) 409 7000
mexico@crouzet.com
InnoVista Sensors™
2 rue du Docteur Henri Abel,
CS 60059
26902 Valence Cedex 9
FRANCE
Tel.: +33 (0) 475 802 101
Fax: +33 (0) 475 828 900
relationclient@crouzet.com
InnoVista Sensors™
Gewerbepark - Postfach 56
5506 Mägenwil - SCHWEIZ
Tel.: +49 (0) 2103/980-0
Fax: +49 (0) 2103/980-222
kundenservice@crouzet.com
InnoVista Sensors™
4th floor, Trident Towers, #23 100
Feet Ashoka Pillar Road,
2nd Block, Jaynagar
Bangalore 560 011 - INDIA
Tel.: +91 (80) 4113 2204/05
Fax: +91 (80) 4113 2206
india@crouzet.com
USA
GERMANY / AUSTRIA
THE NETHERLANDS
SOUTH KOREA
InnoVista Sensors™
1461 Lawrence Drive
Thousand Oaks, CA 91320
USA
Tel.: +1 (800) 677 5311
Fax: +1 (800) 677 3865
customer.service@us.crouzet.com
InnoVista Sensors™
Otto-Hahn-Str. 3
40721 Hilden
DEUTSCHLAND
Tel.: +49 (0) 2103/980-0
Fax: +49 (0) 2103/980-222
kundenservice@crouzet.com
InnoVista Sensors™
Industrieweg 17
2382 NR Zoeterwoude
NEDERLAND
Tel.: +31 (0) 71-581 20 30
Fax: +31 (0) 71-541 35 74
klantenservice@crouzet.com
InnoVista Sensors™
14F, Kbiz DMC Tower,
189, Seongam-Ro, Mapo-Gu,
Seoul 121-904
SOUTH KOREA
Tel.: +82 (2) 2629 8312
Fax: +82 (2) 2630 9800
korea@crouzet.com
COUNTRIES NOT LISTED
ITALY
COUNTRIES NOT LISTED
EAST ASIA PACIFIC
InnoVista Sensors™
1461 Lawrence Drive
Thousand Oaks, CA 91320
USA
Tel.: +1 (800) 677 5311
Fax: +1 (800) 677 3865
customer.service@us.crouzet.com
InnoVista Sensors™
Via Viganò De Vizzi, 93/95
20092 Cinisello Balsamo (Mi)
ITALIA
Tel.: +39 (02) 66 599 211
Fax: +39 (02) 66 599 218
assistenzaclienti@crouzet.com
www.crouzet.it
InnoVista Sensors™
2 rue du Docteur Henri Abel,
CS 60059
26902 Valence Cedex 9
FRANCE
Tel.: +33 (0) 475 802 102
Fax: +33 (0) 475 828 900
customer.relation@crouzet.com
InnoVista Sensors™
10/F, Wharf T&T Centre, Harbour
City, 7 Canton Road, Tsim Sha Tsui,
Kowloon, HONG KONG
Tel.: +86 (21) 8025 7177
Fax: +86 (21) 6107 1771
eap@crouzet.com
WWW.CROUZET-CONTROL.COM
ASIA / PACIFIC
WWW.INNOVISTASENSORS.COM
Warning:
The product information contained in this catalogue is given purely as information and does not constitute a representation, warrantly or any form of contractual commitment. Crouzet
Automatismes SAS and its subsidiaries reserve the right to modify their products without notice. It is imperative that we should be consulted over any particular use or application of our
products and it is the responsability of the buyer to establish, particularly through all the appropriate tests, that the product is suitable for the use or application. Under no circumstances
will our warranty apply, nor shall we be held responsible for any application (such as any modification, addition, deletion, use in conjunction with other electrical or electronic components,
circuits or assemblies, or any other unsuitable material or substance) which has not been expressly agreed by us prior to the sale of our products.
Ref.: 6711106A EN | 02/2016 - Photos: Ginko, Daniel lattard, Schneider Electric, Fotolia, Shutterstock
AMERICAS