F1770AA06

F1770AA06

  • 厂商:

    CURTISINDUSTRIES

  • 封装:

    -

  • 描述:

    F1770AA06

  • 数据手册
  • 价格&库存
F1770AA06 数据手册
RFI RFI Power Power Line Line Filters Filters Terminal Blocks Family FamilyofofProducts Products > RFI RFI FIlters FIlters >> > Filtered Filtered Power Power Entry Entry >> > Custom Custom Filters Filters >> > Terminal Terminal Blocks Blocks >> > Custom Custom Terminal Terminal Blocks Blocks >> > Liquid Liquid Level Level Controllers Controllers >> > PCB PCB Mount Mount Blocks Blocks >> > DIN DIN Rail Rail RFI POWER LINE FILTERS >> R5 4.12 2400 2400 S. 43rd. S. 43rd. St. St. Milwaukee, Milwaukee, WI WI 53219 53219 1-800-657-0853 1-800-657-0853 www.curtisind.com www.curtisind.com Innovative Innovative Innovative Engineering Engineering Engineering Solutions Solutions Solutions Contents Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 SINGLE PHASE FILTERS ] General Purpose F1100/F1150/F1199 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 F1200/F1250/F1299 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 F1300/F1350/F1399 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 F1900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 High Performance F1400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 F1500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 F1600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 F1700/F1799 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 F1760/F1770/F1780 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 F2800 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Wide Band F5100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 F5200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 F5500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32 F5600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34 F5700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 F5900 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Single Phase Filter Cutouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 ] General Purpose Filtered Modules POWER ENTRY MODULES F2199/F2200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44 F2300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 F2400/F2500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 F2600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48 F2700 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Combination FPE7/FPE8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 FPE1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 Power Entry Module Cutouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 THREE-PHASE FILTERS ] F3480/F3600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60 DC FILTERS ] FD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64 General Purpose FD00 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67 FD02 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 High Performance FD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69 FD2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 FD3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 ] General Purpose Filtered Modules MEDICAL FILTERS F3099 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72 F3000/3100/F3200/F3400/F3500 . . . . . . . . . . . . . . . . . . . . . . . . . 73 F3300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75 Combination FPM7/FPM8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77 FPM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 TECHNICAL CONSIDERATIONS ] Understanding Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 Technical Considerations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 86 Conducted Emissions Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88 Custom Filter Capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 1 F1100/F1150 Curtis Industries Filter RFI Filters Selection Guide F1150 F1200/1299 SINGLE PHASE SINGLE PHASE F1250 POWER ENTRY 0 .5 1 .0 • • 0 .25 0 .40 • • Solder Term. • Screw •• • • P.C. Term • • Switch •• 1 .0 0 .40 Volt Select •• 0 .5 0 .25 I.E.C. • • • 4 • • 4 • • • 7 • • • • 7 •• 0 .5 1 .0 • • • • • 11 ••• •• 0 .25 0 .40 • • • • • 11 F1900 • • 0 .25 0 .40 • 15 F1400 ••••• •••• 0 .25 0 .40 F1500 •••• ••• 0 .25 0 .40 F1600 ••••• ••• 0 .25 0 .40 • • • • • • • • • • • • •• •••• 0 .5 1 .0 • • •••• •••• 0 .5 1 .0 • • F2800 ••••• ••••• 0 .25 0 .50 • • F5100 •• •• 0 .25 0 .50 F1700/1799 F1760/1700/1780 •• •• 0 .25 0 .50 F5500 •••• •••• 0 .25 0 .50 • F5600 ••••• •••• 0 .50 1 .20 • F5700 •••• ••••• 0 .50 1 .20 • F5900 ••••• •••• 0 .50 1 .20 • • • 0 .25 0 .40 • ••• •• 0 .25 0 .40 F2300 • 16 • 18 • 20 • • 22 • • 24 • 26 • 28 • • F5200 • • 30 • 32 • 34 • 36 • 38 • • 44 • • • 45 • F2400/2500 • • 0 .25 0 .40 • F2600 • • 0 .25 0 .40 • F2700 ••••• ••••• 0 .25 0 .40 • • • • • • 46 • 48 • • 50 • 52 • • 52 • • 56 • • FPE7 • • 0 .25 0 .40 • • • • • 0 .25 0 .40 • • • FPE1 •• •• 0 .25 0 .40 • • • •••• •••• • • • FPE8 • • • • • 60 FD00 67 FD02 68 FD1 69 (See Section on DC filters for more information) FD2 70 FD3 70 0 .002 0 .005 • • • • •• F3000/3100/3200/3400/3500 • •• 0 .002 0 .005 • F3300 • • 0 .015 0 .025 • FPM7 • • 0 .002 0 .005 • • • FPM8 • • 0 .002 0 .005 • • • FPM1 •• •• 0 .002 0 .005 • • • F3099 MEDICAL •• • mA @250VAC •••• F1300/1399 F3480/F3600 DC FILTERS THREE-PHASE •• mA @115VAC Catalog Page Number F1350 F2199/2200 2 Differential Mode Q.C. F1100/1199 Common Mode Wire Filter Series MAXIMUM LEAKAGE CURRENT Fused I.E.C. PACKAGE/TERMINATION PERFORMANCE RELATIVE ATTENTUATION www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . • • • 73 • 75 • 77 • • 77 • • 81 • • • 72 • Specifications subject to change. SINGLE PHASE FILTERS ] General Performance High Performance SINGLE PHASE FILTERS Wide Band Curtis Industries A Division of Powers Holdings, Inc . 3 F1100/F1150/F1199 RFI Filters Features: SINGLE PHASE FILTERS F1100/F1150/F1199 Simplified Schematic LI NE General Purpose • Most Economical Design • Designed for General Purpose, Common Mode Applications • Available in Standard (F1100) and Low-Leakage (F1150) (F1160) (F1170) (F1180) (F1190) (F1199) Models L G N Nominal Current Rating 1A 2A 3A 6A 10A 20A 30A Part Number Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Frequency - MHz .15 .50 1.0 5.0 10 30 F1100AA01 F1100BB01 QC/QC Wire/Wire Common Differential 20 35 43 52 55 55 65 50 50 F1150AA01 F1150BB01 QC/QC Wire/Wire Common Differential 20 30 37 50 55 50 65 50 50 F1199AA01 QC/QC Common Differential 32 5 45 14 45 23 43 47 43 50 40 45 F1199AA02 F1199BB02 QC/QC Wire/Wire Common Differential 24 5 35 13 43 16 45 45 45 50 40 45 F1100AA03 F1100BB03 F1100PP03 QC/QC Wire/Wire PC/PC Common Differential 20 35 43 52 55 55 64 50 46 F1150AA03 F1150BB03 QC/QC Wire/Wire Common Differential 20 30 37 50 55 50 64 50 46 F1199AA03 F1199BB03 QC/QC Wire/Wire Common Differential 20 5 30 12 38 14 48 38 48 44 44 42 F1100AA06 F1100BB06 QC/QC Wire/Wire Common Differential 10 22 2 30 5 46 51 50 57 45 49 F1150AA06 F1150BB06 QC/QC Wire/Wire Common Differential 10 20 2 27 5 45 51 45 57 45 49 F1199AA06 F1199BB06 QC/QC Wire/Wire Common Differential 9 5 20 12 28 14 42 33 50 42 47 42 F1100AA10 F1100BB10 QC/QC Wire/Wire Common Differential 10 22 30 2 46 27 50 47 45 50 F1150AA10 F1150BB10 QC/QC Wire/Wire Common Differential 10 20 27 2 45 27 45 47 45 50 F1199AA10 F1199BB10 F1199DD10 QC/QC Wire/Wire Screw/Screw Common Differential 9 5 20 12 25 14 38 33 42 42 40 42 F1100AA20 F1100DD20 QC/QC Screw/Screw Common Differential 8 18 22 5 36 22 42 46 45 60 F1150AA20 F1150DD20 QC/QC Screw/Screw Common Differential 8 15 20 5 32 22 38 46 45 60 F1199AA20 F1199DD20 QC/QC Screw/Screw Common Differential 10 5 20 12 28 15 35 30 38 40 40 40 F1199DD30 Screw/Screw Common Differential 13 5 23 12 30 15 35 30 38 40 40 40 NOTE: Other combinations of terminals may be specified on special order. 4 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . Specifications: (1, 3, 6, 10 and 20Amp) Dimensions Amps A B C D E 1A 2 .500 (63,5) 1 .750 (44,5) .625 (15,8) 2 .125 (53,9) 1 .425 (362) 3A 2 .500 (63,5) 1 .750 (44,5) .750 (19,1) 2 .125 (53,9) 1 .8 (45,8) 6A 2 .500 (63,5) 1 .750 (44,5) .750 (19,1) 2 .125 (53,9) 1 .8 (45,8) 10A 2 .500 (63,5) 1 .750 (44,5) 1 .125 (28,5) 2 .125 (53,9) 1 .8 (45,8) 20A 2 .760 (70,6) 2 .000 (60,8) 1 .125 (28,5) 2 .375 (60,3) 2 .550 (64,8) .188 Dia . (4,77) 2 Holes L I N E B L O A D D A 064179 72031204 (Except F1100/F1150 20-amp) (Except F1100/F1150 20-amp) .250 Q .C . (6.4) F1100BB/FB1150BB (1, 3, 6 and 10Amp) Dimensions F1100DD/F1150DD (20Amp Only) Dimensions .188 Dia . (4,77) 2 Holes 2 .000 (50,8) (5) No. 8-32 .625 Studs (15,8) L I N E L O A D 2 .760 (70,6) Amps A B C D E 1A 2 .500 (63,5) 1 .750 (44,5) .625 (15,8) 2 .125 (53,9) .875 (22,2) 3A 2 .500 (63,5) 1 .750 (44,5) .750 (19,1) 2 .125 (53,9) 1 .250 (31,8) 6A 2 .500 (63,5) 1 .750 (44,5) .750 (19,1) 2 .125 (53,9) 1 .250 (31,8) 10A 2 .500 (63,5) 1 .750 (44,5) 1 .125 (28,5) 2 .125 (53,9) 1 .250 (31,8) .188 Dia . (4,77) 2 Holes 2 .375 (60,3) B 2 .000 (50,8) .625 (15,8) 1 .125 (25,5) L I N E L O A D E C Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . SINGLE PHASE FILTERS E C E78454 General Purpose Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 1A 1A 2A 1 .5A 3A 2 .5A 6A 4A 10A 6A 20A 10A 30A 15A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): F1100/F1150 F1199 Line to Ground: 1500VAC 1500VAC Line to Line: 1768VDC 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect D: Screw B: Wire P: PCB Pins Maximum Leakage Current: Each Line to Ground F1100 F1150 F1199 115VAC, 60Hz: 0.40mA 0.25mA 0.25mA 250VAC, 50Hz: .75mA 0.40mA 0.45mA Agency Approvals: F1100AA/F1150AA Curtis Industries A Division of Powers Holdings, Inc . A D 4 .000 (101,6) Min . .250± .062 (6,35) Typ. No. 18 Gauge Wire 1-800-657-0853 5 F1100/F1150/F1199 RFI Filters (continued) SINGLE PHASE FILTERS General Purpose F1199AA (1, 2, 3, 6, 10 and 20Amp) Dimensions F1199BB (2, 3, 6 and 10Amp) Dimensions Amps A B C D E Amps A B C D E 1A 2 .53 (64,3) 1 .82 (46,2) 0 .66 (16,8) 2 .126 (54,0) 2 .25 (57,2) 2A 2 .53 (64,3) 1 .82 (46,2) 0 .66 (16,8) 2 .126 (54,0) 0 .96 (24,4) 2A 2 .53 (64,3) 1 .82 (46,2) 0 .66 (16,8) 2 .126 (54,0) 2 .25 (57,2) 3A 2 .53 (64,3) 1 .82 (46,2) 0 .78 (19,8) 2 .126 (54,0) 1 .32 (33,5) 3A 2 .53 (64,3) 1 .82 (46,2) 0 .78 (19,8) 2 .126 (54,0) 2 .61 (66,3) 6A 2 .53 (64,3) 1 .82 (46,2) 0 .78 (19,8) 2 .126 (54,0) 1 .32 (33,5) 6A 2 .53 (64,3) 1 .82 (46,2) 0 .78 (19,8) 2 .126 (54,0) 2 .61 (66,3) 10A 2 .53 (64,3) 1 .82 (46,2) 1 .16 (29,5) 2 .126 (54,0) 1 .32 (33,5) 10A 2 .53 (64,3) 1 .82 (46,2) 1 .16 (29,5) 2 .126 (54,0) 2 .61 (66,3) 20A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .36 (85,3) WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. BLUE 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) A D A D G/Y BROWN BROWN B E B E BLUE C C F1199DD (10, 20 and 30Amp) Dimensions Amps A B C D E 10A 2 .53 (64,3) 1 .82 (46,2) 1 .16 (29,5) 2 .126 (54,0) 2 .72 (69,1) 20A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .46 (87,9) 30A 4 .20 (106,7) 3 .38 (85,9) 1 .53 (38,9) 3 .75 (95,25) 5 .34 (135,6) MOUNTING FLANGE #8-3 SCREW TERMINAL F1100PP Recommended PC Mounting .250 Dia . Pads 5 Places 1 .75 .210 A D E Stamp this surface 1 .25 B C L I N E .062 Dia . Hole 5 Places L O A D .500 .750 1 .00 .75 6 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1200/F1250/F1299 RFI Filters Features: • Designed for General Purpose Common Mode and Differential Mode Applications • Higher Line-to-Line Capacitance for Protection from Pulsed, Intermittent, or Continuous RFI 1A 2A 6A 10A 20A 30A Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 F1200AA01 F1200BB01 QC/QC Wire/Wire Common Differential 20 4 35 38 43 59 52 66 55 62 50 54 F1250AA01 F1250BB01 QC/QC Wire/Wire Common Differential 20 4 30 38 37 59 50 66 50 62 50 54 F1299AA02 F1299BB02 QC/QC Wire/Wire Common Differential 24 6 35 35 43 50 45 55 45 50 40 45 F1200AA03 F1200BB03 F1200CA03 QC/QC Wire/Wire IEC/QC Common Differential 20 4 35 38 43 59 52 70 55 64 50 59 F1250AA03 F1250BB03 F1250CA03 QC/QC Wire/Wire IEC/QC Common Differential 20 4 30 38 37 59 50 70 50 64 50 59 F1299AA03 F1299BB03 F1299CA03 QC/QC Wire/Wire IEC/QC Common Differential 26 6 37 40 45 55 45 55 45 50 40 45 F1200AA06 F1200BB06 F1200CA06 QC/QC Wire/Wire IEC/QC Common Differential 10 9 22 25 30 48 46 70 50 70 45 62 F1250AA06 F1250BB06 F1250CA06 QC/QC Wire/Wire IEC/QC Common Differential 10 9 20 25 27 48 45 70 45 70 45 62 F1299AA06 F1299BB06 F1299CA06 QC/QC Wire/Wire IEC/QC Common Differential 20 6 31 35 40 50 45 55 45 50 40 45 F1200AA10 F1200BB10 F1200CA10 QC/QC Wire/Wire IEC/QC Common Differential 10 10 22 16 30 43 46 70 50 70 45 66 F1250AA10 F1250BB10 F1250CA10 QC/QC Wire/Wire IEC/QC Common Differential 10 10 20 16 27 43 45 70 45 70 45 66 F1299AA10 F1299BB10 F1299CA10 F1299DD10 QC/QC Wire/Wire IEC/QC Screw/Screw Common Differential 9 14 20 14 25 38 38 50 42 48 40 45 F1200AA20 F1200DD20 QC/QC Screw/Screw Common Differential 10 9 22 19 30 44 42 70 47 70 40 70 F1250AA20 F1250DD20 QC/QC Screw/Screw Common Differential 10 9 20 19 25 44 38 70 40 70 40 70 F1299AA20 F1299DD20 QC/QC Screw/Screw Common Differential 10 14 20 14 28 38 35 50 38 48 40 45 F1200DD30 Screw/Screw Common Differential 7 11 15 13 20 44 34 70 42 60 40 57 F1299DD30 Screw/Screw Common Differential 12 15 23 40 30 55 35 55 38 55 40 50 SINGLE PHASE FILTERS 3A Part Number General Purpose Nominal Current Rating • Available in Standard (F1200) and Low-Leakage (F1250) (F1260) (F1270) (F1280) (F1299) Models • Available with Integral IEC Connector up to 10Amps NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 7 F1200/F1250/F1299 RFI Filters (continued) SINGLE PHASE FILTERS E78454 064179 72031204 E78454 099523 72102892 L LI NE L G N N F1299 Simplified Schematic L L G N N F1280 .015mA .025mA F1290 .030mA .050mA Except 30Amp Agency Approvals F1299: F1200AA/F1250AA (1, 3, 6, 10 and 20Amp) Dimensions Amps A B C D E F 1A 2 .750 (69,9) 2 .00 (50,8) .875 (22,2) 2 .375 (60,3) 1 .750 (44,5) .550 (14,0) 3A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 1 .750 (44,5) .550 (14,0) 6A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 1 .750 (44,5) .550 (14,0) 10A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) .550 (14,0) 20A 3 .310 (84,1) 2 .50 (63,5 ) 1 .500 (38,1) 2 .940 (74,7) 2 .000 (50,8) .550 (14,0) .188 Dia . (4,77) 2 Holes L I N E B F L O A D Amps A B C D E 1A 2 .750 (69,9) 2 .00 (50,8) .875 (22,2) 2 .375 (60,3) 1 .750 (44,5) 3A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 1 .750 (44,5) 6A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 1 .750 (44,5) 10A 2 .750 (69,9) 2 .00 (50,8) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) www .curtisind .com A D E F C .250 QC (6,4) F1200BB/FB1250BB (1, 3, 6 and 10Amp) Dimensions 8 LO A D Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 1A 2A 3A 6A 10A 20A 30A 250VAC 1A 1 .5A 2 .5A 4A 6A 10A 15A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): F1200 Series F1299 Series Line to Ground: 1500VAC 1500VAC Line to Line: 1768VDC 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect C: IEC Receptacle B: Wire D: Screw Maximum Leakage Current: Each Line to Ground F1200 F1250 F1299 F1260 F1270 115VAC, 60Hz: 0.40mA 0.25mA .25mA .25mA .002mA 250VAC, 50Hz: .75mA .40mA .45mA .45mA .005mA Agency Approvals F1200/F1250: LO A D F1200/F1250 Simplified Schematic LI NE General Purpose Specifications: .188 Dia . (4,77) 2 Holes B .250± .062 (6,35) Typ. 4 .000 (101,6) Min . No. 18 Gauge Wire Curtis Industries A Division of Powers Holdings, Inc . L I N E L O A D D A E C Specifications subject to change. Dimensions are shown for reference purposes only . F1200CA/F1250CA (3, 6, and 10Amp) Dimensions L I N E D (2) No. 6-32 UNC2B L O A D B A C F1200DD/F1250DD A B C D 3A 2 .55 (64,8) 2 .000 (50,8) 1 .50 (38,1) 1 .575 (40,0) 6A 3 .05 (77,5) 2 .000 (50,8) 1 .500 (38,1) 1 .575 (40,0) 10A 3 .05 (77,5) 2 .000 (50,8) 1 .500 (38,1) 1 .575 (40,0) F1200DD30 (20Amp Only) Dimensions (30Amp Only) Dimensions .188 Dia . (4,77) 2 Holes (5) No. 8-32 Studs .625 (15,8) L O A D 2 .940 (74,7) 2 .000 (50,8) 3 .370 (85,57) 3 .312 (84,1) .625 (15,8) .590 (14,99) L O A D 3 .750 (95,25) 3 .140 (79,75) 1 .520 (38,61) 1 .500 (38,1) Also Available with .250” Quick Connect Terminals L I N E 2 .000 (50,8) No. 8-32 Stud 4 .140 (105,2) .250 X .156 Slot 3 .875 (98,42) F1299AA (2, 3, 6, 10 and 20Amp) Dimensions Amps A B C D E 2A 2 .81 (71,4) 2 .07 (52,6) 0 .91 (23,1) 2 .375 (60,33) 3 .10 (78,7) 3A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .10 (78,7) 6A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .10 (78,7) 10A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .35 (85,1) 20A 3 .35 (85,1) 2 .56 (65,0) 1 .53 (38,9) 2 .938 (74,63) 3 .35 (85,1) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . SINGLE PHASE FILTERS 2 .500 (63,5) .600 (15,24) L I N E General Purpose Refer to Page 40 for Standard Mounting Cutouts Amps 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) A D B E Curtis Industries A Division of Powers Holdings, Inc . C 1-800-657-0853 9 F1200/F1250/F1299 RFI Filters (continued) SINGLE PHASE FILTERS General Purpose F1299BB (2, 3, 6 and 10Amp) Dimensions Amps A B C D E 2A 2 .81 (71,4) 2 .07 (52,6) 0 .91 (23,1) 2 .375 (60,33) 1 .81 (46,0) 3A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .10 (78,7) 6A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .10 (78,7) 10A 2 .81 (71,4) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 2 .07 (52,6) WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. BLUE A D BLUE G/Y BROWN BROWN B E C F1299CA (3, 6 and 10Amp) Dimensions Amps A B C D 3A 3 .21 (81,5) 2 .25 (57,2) 1 .28 (32,5) 1 .575 (40,0) 6A 3 .21 (81,5) 2 .25 (57,2) 1 .28 (32,5) 1 .575 (40,0) 10A 3 .71 (94,2) 2 .25 (57,2) 1 .28 (32,5) 1 .575 (40,0) B #6-32 INSERT C A 16.0 (0.63) 6.35(0.25) FASTON TERMINAL, WITH Ø1.78(0.070) HOLE (SLOTTED HOLE FOR GROUND) D IEC CONNECTOR F1299DD (10, 20 and 30Amp) Dimensions Amps A B C D E 10A 2 .81 (71,40) 2 .07 (52,6) 1 .16 (29,5) 2 .375 (60,33) 3 .46 (87,9) 20A 3 .35 (85,1) 2 .56 (65,0) 1 .53 (38,9) 2 .938 (74,63) 3 .46 (87,9) 30A 4 .20 (106,7) 3 .38 (85,9) 1 .53 (38,9) 3 .750 (95,25) 5 .34 (135,6) MOUNTING FLANGE #8-3 SCREW TERMINAL A D B E C SLOTTED HOLE, 6.4(.25)X4.0(.16) #8-32 SCREW TERMINAL A B D 50.8 (2.00) E 10 www .curtisind .com C Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1300/F1350/F1399 RFI Filters Features: Nominal Current Rating 1A 2A 6A 10A 15A 20A Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 F1300AA01 F1300BB01 QC/QC Wire/Wire Common Differential 40 2 65 57 65 69 65 70 65 70 65 60 F1350AA01 F1350BB01 QC/QC Wire/Wire Common Differential 30 2 60 57 65 69 65 70 65 70 65 60 F1399AA02 F1399BB02 QC/QC Wire/Wire Common Differential 40 5 65 45 65 70 65 65 65 60 40 50 F1300AA03 F1300BB03 F1300CA03 F1300CP03 QC/QC Wire/Wire IEC/QC IEC/PC Common Differential 40 7 65 64 65 70 65 70 65 70 65 58 F1350AA03 F1350BB03 F1350CA03 F1350CP03 QC/QC Wire/Wire IEC/QC IEC/PC Common Differential 30 7 60 64 65 70 65 70 65 70 65 58 F1399AA03 F1399BB03 F1399CA03 QC/QC Wire/Wire IEC/QC Common Differential 40 12 65 55 65 70 65 65 65 60 40 50 F1300AA06 F1300BB06 F1300CA06 QC/QC Wire/Wire IEC/QC Common Differential 12 10 48 40 60 70 65 70 65 70 65 60 F1350AA06 F1350BB06 F1350CA06 QC/QC Wire/Wire IEC/QC Common Differential 2 10 40 40 60 70 65 70 65 70 65 60 F1399AA06 F1399BB06 F1399CA06 QC/QC Wire/Wire IEC/QC Common Differential 30 5 55 40 65 70 65 65 65 60 40 50 F1300AA10 F1300BB10 F1300CA10 QC/QC Wire/Wire IEC/QC Common Differential 12 13 48 13 60 64 65 70 65 67 65 56 F1350AA10 F1350BB10 QC/QC Wire/Wire Common Differential 2 13 40 13 60 64 65 70 65 67 65 56 F1399AA10 F1399BB10 F1399CA10 F1399DD10 QC/QC Wire/Wire IEC/QC Screw/Screw Common Differential 5 5 40 12 52 50 60 65 60 60 50 55 F1300AA15 QC/QC Common Differential 14 15 35 10 44 45 56 70 58 67 55 56 F1300AA20 QC/QC Common Differential 5 — 44 — 60 35 65 60 65 57 60 45 F1350AA20 QC/QC Common Differential 2 — 35 — 61 35 63 60 60 57 50 45 F1399AA20 F1399DD20 QC/QC Screw/Screw Common Differential 5 5 40 12 52 50 60 65 60 60 52 55 SINGLE PHASE FILTERS 3A Part Number General Purpose • T Circuit Configuration—Designed for Motor, Capacitive and Other Low Impedance Loads • Dual Coils — Higher Performance in Unknown RFI and Noise Susceptibility Applications • Integral IEC Connector and PC Mounted Versions Now Available NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 11 F1300/F1350/F1399 RFI Filters (continued) General Purpose Specifications: Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 1A 2A 3A 6A 10A 250VAC 1A 1 .5A 2 .5A 4A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): F1300/F1350 Line to Ground: 1500VAC Line to Line: 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect C: IEC Receptacle B: Wire P: PCB Pins Maximum Leakage Current: Each Line to Ground 115VAC, 60Hz: 250VAC, 50Hz: Agency Approvals: SINGLE PHASE FILTERS E78454 F1300 0.4mA .75mA 15A 15A 20A 16A F1350 D1399 0.25mA 0.25mA .40mA 0.45mA F1360 .15mA .25mA F1380 F1390 .015mA .030mA .025mA .050mA 064179 72031204 72031204 Except 15Amp A F1300AA (1, 3, 6, 10 and 15Amp) F1350AA (1, 3, 6 and 10Amp) Dimensions Amps A B C D E 1A 2 .750 (69,9) 1 .750 (44,5) 1 .125 (28,5) 2 .375 (60,3) 2 .925 (74,3) 3A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 3 .49 (88,7) 6A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 3 .49 (88,7) 10A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 3 .49 (88,7) 15A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 3 .49 (88,7) L I N E A B C D E 1A 2 .750 (69,9) 1 .750 (44,5) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) 3A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 2 .500 (63,5) 6A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 2 .500 (63,5) 10A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) B E .250 QC (6,4) (1, 3, 6 and 10Amp) Dimensions www .curtisind .com L O A D C A .188 Dia . (4,77) 2 Holes Amps .188 Dia . (4,77) 2 Holes D F1300BB/F1350BB 12 F1370 .002mA .005mA D L I N E L O A D E C Curtis Industries A Division of Powers Holdings, Inc . B 4 .000 (101,6) Min . .250± .062 (6,35) Typ. No. 18 Gauge Wire Specifications subject to change. Dimensions are shown for reference purposes only . F1300/F1350 Simplified Schematic L G N N LO A D LI NE L L I N E Refer to Page 40 for Standard Mounting Cutouts A B C D E 3A 2 .500 (63,6) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 6A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 10A 2 .880 (73,1) 2 .120 (53,8) 1 .500 (38,1) .65 (16,0) .565 (14,3) L I N E L O A D (2) No. 6-32 UNC2B E B D A C .250 QC (6,4) SINGLE PHASE FILTERS Amps L O A D 2 .000 (50,8) F1300CP/F1350CP (3Amp Only) Dimensions .935 (23,7) (2) No. 6-32 UNC2B .500 (12,7) 1 .500 (38,1) 2 .500 (68,3) .210 (53,3) Refer to Page 40 for Standard Mounting Cutouts 1 .540 (39,1) .25 (6,35) .65 (16,51) F1300AA/F1350AA (20Amp Only) Dimensions General Purpose F1300CA (3, 6 and 10Amp) F1350CA (3 and 6Amp) Dimensions .65 (16,51) 3 .75 (95,25) 3 .35 (85,09) .156 (3,96) 2 .00 (50,8) 1 .52 (38,61) 4 .12 (104.64) .96 (24,38) 3 .92 (99,56) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 13 F1100/F1150 F1300/F1399 RFI RFI Filters Filters (continued) F1399 Simplified Schematic BLUE BROWN BROWN LO A D LI NE General Purpose SINGLE PHASE FILTERS BLUE G/Y D C Amps A B C D E 2A 3 .35 (85,1) 1 .81 (46,0) 1 .16 (29,5) 2 .375 (60,33) 2 .78 (70,6) 3A 3 .85 (97,8) 2 .07 (52,6) 1 .16 (29,5) 2 .938 (74,63) 3 .35 (85,1) 6A 3 .85 (97,8) 2 .07 (52,6) 1 .16 (29,5) 2 .938 (74,63) 3 .35 (85,1) 10A 3 .85 (97,8) 2 .07 (52,6) 1 .53 (38,9) 2 .938 (74,63) 3 .35 (85,1) 20A 5 .23 (132,8) 3 .37 (85,6) 1 .53 (38,9) 3 .75 (95,25) 4 .20 (106.7) F1399DD (10 and 20Amp) Dimensions Amps A B C D E 10A 3 .96 (100,6) 2 .07 (52,6) 1 .53 (38,9) 2 .938 (74,63) 3 .35 (85,1) 20A 5 .34 (135,6) 3 .37 (85,6) 1 .53 (38,9) 3 .75 (95,25) 4 .20 (106,7) D Amps A B C D E 2A 2 .07 (52.6) 1 .81 (46,0) 1 .16 (29,5) 2 .375 (60,33) 2 .78 (70,6) 3A 2 .56 (65,0) 2 .07 (52,6) 1 .16 (29,5) 2 .938 (74,63) 3 .35 (85.1) 6A 2 .56 (65,0) 2 .07 (52,6) 1 .16 (29,5) 2 .938 (74,63) 3 .35 (85.1) 10A 2 .56 (65,0) 2 .07 (52,6) 1 .53 (38,9) 2 .938 (74,63) 3 .35 (85,1) B C 16.0 (0.63) 6.35(0.25) FASTON TERMINAL, WITH Ø1.78(0.070) HOLE (SLOTTED HOLE FOR GROUND) D IEC CONNECTOR F1399CA (3, 6 and 10Amp) Dimensions Amps A B C D 3A 4 .33 (110,0) 2 .25 (57,2) 1 .28 (32,5) 1 .575 (40,0) 6A 4 .33 (110,0) 2 .25 (57,2) 1 .28 (32,5) 1 .575 (40,0) 10A 4 .33 (110,0) 2 .25 (57,2) 1 .53 (38,9) 1 .575 (40,0) #8-32 SCREW TERMINAL SLOTTED HOLE, 6.4(.25)X4.0(.16) #8-32 SCREW TERMINAL A B D C 50.8 (2.00) E www .curtisind .com A #6-32 INSERT B E A C F1399BB (2, 3, 6 and 10Amp) Dimensions B A E B D A 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) F1399AA (2, 3, 6, 10 and 20Amp) Dimensions 14 WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. E Curtis Industries A Division of Powers Holdings, Inc . C Specifications subject to change. Dimensions are shown for reference purposes only . F1900 RFI Filters Specifications: • Designed for Equipment Requiring UL1410 Approval (Consumer Electronics) • Utilizes UL1414 Approved Components • Greater Differential Mode Protection General Purpose Features: Rated Voltage: 125VAC Maximum - 50/60 Hz Rated Current: 120VAC 3A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated urrent Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect Maximum Leakage Current: Each Line to Ground F1900 115VAC, 60Hz: 0.25mA Agency Approvals: F1900 Simplified Schematic L LOAD G E78454 064179 N N SINGLE PHASE FILTERS LINE L .188 Dia . (4,77) 2 Holes F1900AA (3 and 6Amp) Dimensions 2 .375 (60,3) L O A D L I N E 2 .000 (50,8) 2 .750 (69,9) 1 .750 (44,4) .550 (14) .550 (14) 1 .125 (28,5) .250 QC (6,4) Nominal Current Rating Part Number Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 3A F1900AA03 QC/QC Common Differential 20 7 30 19 37 28 50 50 50 57 50 70 6A F1900AA06 QC/QC Common Differential 10 8 20 18 27 24 45 45 45 52 45 64 NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 15 Specifications: Features: • High Peak Current Design — High Insertion Loss for Switching Power Supply Emissions • Low-Leakage Current • Compact Case Sizes in 6 and 10Amp Models • Available with Integral IEC Connector in 3 and 6Amp Models F1400 Simplified Schematic G N N LOAD L L LINE SINGLE PHASE FILTERS High Performance F1400 RFI Filters Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A 10A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect B: Wire C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F1400 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: E78454 Nominal Current Rating Part Number Termination Line/Load 064179 72031235 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 3A F1400AA03 F1400BB03 F1400CA03 QC/QC Wire/Wire IEC/QC Common Differential 58 40 65 60 65 65 65 65 60 65 44 60 6A F1400AA06 F1400BB06 F1400CA06 QC/QC Wire/Wire IEC/QC Common Differential 58 36 65 55 65 60 65 60 60 55 54 50 10A F1400AA10 F1400BB10 QC/QC Wire/Wire Common Differential 56 40 65 50 65 60 65 65 60 65 54 60 NOTE: Other combinations of terminals may be specified on special order. 16 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1400AA (3, 6 and 10Amp) Dimensions D A .188 Dia . (4,77) 2 Holes L O A D F B E F C .250 QC (6,4) Amps A B C D E F 3A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 6A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 10A 4 .70 (119,4) 2 .250 (57,1) 1 .750 (44,4) 4 .250 (107,9) 3 .750 (95,3) .550 (14,0) Amps A B C D E 3A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) 6A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) 10A 4 .70 (119,4) 2 .250 (57,1) 1 .750 (44,4) 4 .250 (107,9) 3 .750 (95,3) D A L I N E L O A D B 4 .00 E .250± .062 (6,35) Typ. (101,6) Min . C SINGLE PHASE FILTERS F1400BB (3, 6 and 10Amp) Dimensions High Performance L I N E No. 18 Gauge Wire F1400CA (3 and 6Amp) Dimensions E L I N E 6-32 Tap 2-Places L O A D A C Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . B D .250 QC (6,4) Refer to Page 40 for Standard Mounting Cutouts Amps A B C D E 3A 2 .880 (73,1) 2 .120 (53,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 6A 2 .880 (73,1) 2 .120 (53,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 17 F1500 RFI Filters Features: • IEC Connector Plus Common and Differential Mode Performance in Compact Case • “L” Circuit Configuration — Cost-Effective in Many Linear and Switching Power Supply Applications • High-Inductance Design for Greater Attenuation • Available with 0.250" Quick Connect Terminals or Wire Leads on the Load Side Termination Line/Load G N N N Part Number L LOAD L OAD G N 064179 72031307 L L L LINE E78454 F1500FA Simplified Schematic F1500CA Simplified Schematic Nominal Current Rating Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 3A 10A 6A 15A 8A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect C: IEC Receptacle F: IEC Receptacle with Fuse Holder Maximum Leakage Current: Each Line to Ground F1500 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: LINE SINGLE PHASE FILTERS High Performance Specifications: MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 3A F1500CA03 F1500FA03 IEC/QC Fused IEC/QC Common Differential 32 35 43 60 50 65 50 60 50 55 50 40 6A F1500CA06 F1500FA06 IEC/QC Fused IEC/QC Common Differential 32 30 42 60 45 65 45 65 45 60 45 50 10A F1500CA10 F1500FA10 IEC/QC Fused IEC/QC Common Differential 29 15 36 50 39 65 45 65 45 60 45 50 15A F1500CA15 IEC/QC Common Differential 26 35 32 60 36 65 44 65 46 65 52 65 NOTE: Other combinations of terminals may be specified on special order. 18 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1500CA E (3, 6, 10 and 15Amp) Dimensions Refer to Page 40 for Standard Mounting Cutouts L O A D L I N E B High Performance (2) No. 6-32 UNC2B A B C D E 3A 2 .000 (50,8) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 6A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 10A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 15A 3 .25 (82,6) 2 .25 (57,2) 1 .75 (44,5) .550 (14,0) .705 (17,9) C .250 QC (6,4) F1500FA L O A D L I N E (3, 6 and 10Amp) Dimensions Refer to Page 40 for Standard Mounting Cutouts (2) No. 6-32 UNC2B Amps A B C D E 3A 2 .000 (50,8) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .752 (19,1) 6A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .752 (19,1) 10A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .752 (19,1) A C Curtis Industries A Division of Powers Holdings, Inc . B D SINGLE PHASE FILTERS (1) 5mm x 20mm Fuse (not included) E Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . D A Amps .250 QC (6,4) 1-800-657-0853 19 Specifications: Features: • T Section, Dual Coil Design – High Insertion Loss for Switching Power Supply Emissions • Low-Leakage Current Design • Space-Efficient with Integral IEC Connector and Compact Case in Current Ratings up to 10Amps • Available in Fused IEC Connector and PC Mounted Versions F1600CX Simplified Schematic L LOAD L LINE SINGLE PHASE FILTERS High Performance F1600 RFI Filters G N N F1600FA Simplified Schematic L L OAD LINE L G N Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 3A 10A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect B: Wire C: IEC Receptacle F: Fused IEC P: PCB Pins Maximum Leakage Current: Each Line to Ground F1600 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: N E78454 Nominal Current Rating Part Number Termination Line/Load 064179 72031235 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 3A F1600CA03 F1600CP03 F1600FA03 F1600CB03 IEC/QC IEC/PC Fused IEC/QC IEC/Wire Common Differential 52 40 65 50 65 60 65 65 65 65 65 50 6A F1600CA06 F1600CP06 F1600FA06 F1600CB06 IEC/QC IEC/PC Fused IEC/QC IEC/Wire Common Differential 45 30 65 45 65 55 65 50 65 50 59 50 10A F1600CA10 F1600CB10 IEC/QC IEC/Wire Common Differential 50 23 65 45 65 55 65 50 65 50 54 50 NOTE: Other combinations of terminals may be specified on special order. 20 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1600CA (3, 6 and 10Amp) Dimensions F1600CB (3, 6 and 10Amp) Dimensions E L O A D Refer to Page 40 for Standard Mounting Cutouts B (2) No. 6-32 UNC2B A D C .250 QC A B C D E 3A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,2) .550 (14,0) .565 (14,3) 6A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,2) .550 (14,0) .565 (14,3) 10A 3 .750 (95,2) 2 .250 (57,2) 1 .750 (44,5) .550 (14,0) .640 (16,3) L O A D L I N E (3 and 6Amp) Dimensions Refer to Page 40 for Standard Mounting Cutouts .935 (19,1) (2) No. 6-32 UNC2B 2,500 (63.5) .500 (12,7) .210 (53,3) 1 .500 (38.2) 1 .540 (39,1) (1) 5mm x 20mm FUSE (not included) .752 (19,1) F1600FA (3 and 6Amp) Dimensions Refer to Page 40 for Standard Mounting Cutouts 2 .00 (50,8) L O A D L I N E (2) No. 6-32 UNC2B 2 .500 (63,5) 1 .500 (38,2) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . SINGLE PHASE FILTERS F1600CP Amps High Performance L I N E B .550 (14.0) .250 QC (6,4) Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 21 F1700/F1799 RFI Filters Specifications: F1700 Simplified Schematic L LOA D L G N N F1799 Simplified Schematic L LOAD L LINE SINGLE PHASE FILTERS Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 2 .5A 6A 4A 10A 6A 20A 10A 30A 15A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect C: IEC Receptacle B: Wire D: Screw Maximum Leakage Current: Each Line to Ground F1700 F1710 F1720 F1740 F1799 115VAC, 60Hz: 0.40mA .15mA .002mA .060mA 0.25mA 250VAC, 50Hz: 0.75mA .25mA .005mA .120mA 0.45mA Agency Approvals: • General Purpose — Designed for Applications with Higher Differential Mode Noise • Higher Line-to-Line Capacitance for Protection from Pulsed, Intermittent or Continuous RFI • A Cost-Effective Replacement for Independent Coil Design in Many SMPS Applications • Available with Integral IEC Connector LINE High Performance Features: G Nominal Current Rating E78454 N N Part Number Termination Line/Load 064179 72031235 Except F1700DD30 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 1.0 5.0 10 30 Common Differential 20 25 35 60 43 65 52 65 55 50 50 50 QC/QC Common Differential 20 25 34 60 40 65 45 65 45 50 40 50 F1720AA03 QC/QC Common Differential 20 35 32 60 35 65 35 60 35 55 40 40 F1740AA03 QC/QC Common Differential 20 35 30 60 35 65 35 60 35 55 40 40 6A F1700AA06 F1700BB06 F1700CA06 QC/QC Wire/Wire IEC/QC Common Differential 10 15 22 50 30 65 46 60 50 60 45 60 10A F1700AA10 F1700BB10 F1700CA10 QC/QC Wire/Wire IEC/QC Common Differential 10 20 22 45 30 60 46 65 50 60 45 55 F1700AA20 QC/QC Common Differential 10 15 22 45 30 60 42 65 47 60 40 55 F1700DD20 F1720DD20 Screw/Screw Common Differential 10 15 22 45 30 60 42 65 47 60 52 55 F1700DD30 Screw/Screw Common Differential 7 15 15 45 20 60 34 65 42 60 40 55 F1799DD30 Screw/Screw Common Differential 10 15 45 65 55 65 60 65 60 60 50 55 3A 20A 30A F1700AA03 F1700BB03 F1700CA03 QC/QC Wire/Wire IEC/QC F1710AA03 NOTE: Other combinations of terminals may be specified on special order. 22 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1700AA, 1710, 1720, 1740 (3, 6 and 10Amp) Dimensions A D L O A D F B C D E F 3A 2 .750 (69,8) 1 .750 (44,4) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) .550 (14,0) 6A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 10A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) B E 20A F .250 QC E A B C D E 3A 2 .750 (69,8) 1 .750 (44,4) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) 6A 3 .312 (84,1) 2 .000 (50,8) 1 .125 (28,5) 2 .940 (74,7) 2 .500 (63,5) 10A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) Refer to Page 40 for Standard Mounting Cutouts C C D E 3A 2 .000 (50,8) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 6A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 10A 2 .500 (63,5) 2 .000 (50,8) 1 .500 (38,1) .550 (14,0) .565 (14,3) 1 .520 (38,6) .250 ± .062 (6,35) Type . .188 Dia . (4.77) 2 Holes 2 .500 (63,5) (5) No. 8-32 Studs .625 (15,87) F1700DD30 (30Amp) Dimensions 5 .075 (128,9) 2 .000 (50,8) L I N E No. 18 Gauge Wire F1700DD20 (20Amp) Dimensions D B B C A A D E B Amps A 4 .00 Min . (101,6) (2) No. 6-32 UNC2B L O A D (4) .250 x .156 (6,35) (3,95) L O A D 4 .140 (105,2) SINGLE PHASE FILTERS Amps L O A D L I N E (3, 6 and 10Amp) Dimensions F1700BB (3, 6 and 10Amp) Dimensions L I N E See 1700DD20 for Case Dimensions F1700CA C (6,4) .188 Dia . (4.77) 2 Holes A High Performance L I N E Amps 3 .312 (84,1) 3 .750 (95,2) Terminals No. 8-32 (5) F1799DD (30Amp) Dimensions L I N E L O A D 2 .000 (50,8) Also Available with .250” Quick Connect Terminals Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . 2 .940 (74,7) 3 .312 (84,1) .625 (15,87) 1 .500 (38,1) SLOTTED HOLE, 6.4(.25)X4.0(.16) #8-32 SCREW TERMINAL 3.5 (88,90) 3.12 (79,2) 3.96 (110,6) 50.8 (2.00) 5.95 (151,1) Curtis Industries A Division of Powers Holdings, Inc . 2.18 (55,4) 1-800-657-0853 23 F1760/F1770/F1780 RFI Filters Features: • Designed for Applications Where Switching Power Supplies, SCR’s and TTL Circuits Are Utilized • Protection from Pulsed, Intermittent or Continuous RFI • Effective CM and DM Suppression for Most FCC VDE Requirements Down to 150KHz • Available in Stud and Quick Connect Terminal Versions F1760 Simplified Schematic 6A 10A 20A 24 Termination Line/Load L LOAD LINE LOAD Part Number 064179 72031306 L G N N N N 3A E78454 L G Nominal Current Rating Rated Voltage: 250VAC, Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 20A 14A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect D: Screw Maximum Leakage Current: Each Line to Ground F1760/1770/1780 115VAC, 60Hz: 0.5mA 250VAC, 50Hz: 1.0mA Agency Approvals: F1770 Simplified Schematic L LINE SINGLE PHASE FILTERS High Performance Specifications: MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 20 30 F1760AA03 F1760DD03 QC/QC Screw/Screw Common Differential 15 40 30 65 40 65 45 60 50 55 45 55 45 55 F1780AA03 F1780DD03 QC/QC Screw/Screw Common Differential 13 40 25 65 40 65 60 62 60 55 55 45 50 45 F1760AA06 F1760DD06 QC/QC Screw/Screw Common Differential 15 40 30 65 35 65 35 65 44 53 43 52 42 50 F1780AA06 F1780DD06 QC/QC Screw/Screw Common Differential 13 40 30 65 40 65 65 62 65 55 53 45 48 45 F1760AA10 F1760DD10 QC/QC Screw/Screw Common Differential 15 40 30 65 35 65 50 55 50 50 40 50 40 50 F1780AA10 F1780DD10 QC/QC Screw/Screw Common Differential 13 40 20 65 35 65 65 62 65 55 55 45 50 45 F1760AA20 F1760DD20 QC/QC Screw/Screw Common Differential 12 41 25 65 31 65 42 65 47 60 50 60 40 55 F1780AA20 F1780DD20 QC/QC Screw/Screw Common Differential 12 41 30 65 32 65 60 65 60 60 60 60 55 55 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F1780 Simplified Schematic LI NE G N N LO A D L L (3, 6, and 10Amp) Dimensions A B C D E F 3A 2 .750 (69,8) 1 .750 (44,4) 1 .125 (28,5) 2 .375 (60,3) 2 .000 (50,8) .550 (14,0) 6A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (28,5) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 10A 3 .312 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) A D L O A D L I N E B E SINGLE PHASE FILTERS F F .250 QC (6,4) C F1760/F1770/1780 (20Amp Only) Dimensions 1 .520 (38,6) 5 .075 (128,9) 2 .000 (50,8) L I N E (4) .250 x .156 (6,35) (3,95) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . High Performance F1760/F1770/1780AA Amps L O A D 4 .140 (105,2) 3 .312 (84,1) 3 .750 (95,2) Terminals No. 8-32 (5) Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 25 High Performance F2800 RFI Filters Specifications: • Designed for VDE “A” and FCC “B” Switching Power Supply Applications • Low-Leakage Current • Compact Case Sizes in Current Ratings up to 15A • Effective Reduction of Common Mode and Differential Mode Noise from 100KHz to 30MHz F2800 Simplified Schematic 3 & 6Amp L LOAD L LINE SINGLE PHASE FILTERS Features: G N N F2800 Simplified Schematic 10 & 15Amp L LOAD LINE L G N N Nominal Current Rating 26 Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A 10A 6A 15A 12A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: A: QC – Quick Connect B: Wire Maximum Leakage Current: Each Line to Ground F2800 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: E78454 Part Number Termination Line/Load 064179 72031309 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .01 .05 .15 Frequency - MHz .50 1.0 5.0 10 30 3A F2800AA03 F2800BB03 QC/QC Wire/Wire Common Differential 10 5 30 25 35 50 35 60 35 65 40 50 45 45 50 45 6A F2800AA06 F2800BB06 QC/QC Wire/Wire Common Differential 5 5 20 10 30 40 35 60 40 60 40 50 40 50 50 45 10A F2800AA10 F2800BB10 QC/QC Wire/Wire Common Differential 5 7 15 20 25 50 30 60 35 60 40 60 45 60 50 55 15A F2800AA15 F2800BB15 QC/QC Wire/Wire Common Differential 8 10 21 30 29 70 33 70 36 70 38 70 45 70 50 60 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . F2800AA (3, 6 and 10Amp) Dimensions A .188 Dia . (4,77) 2 Holes D L O A D F E B F C .250 QC Amps A B C D E F 3A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 6A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,2) 2 .940 (74,7) 2 .500 (63,5) .550 (14,0) 10A 4 .44 (113) 2 .250 (57,1) 1 .750 (44,4) 4 .063 (103,2) 3 .630 (92,2) .650 (16,5) (6,4) F2800BB (3, 6 and 10Amp) Dimensions D L I N E .250± .062 (6,35) Typ. L O A D 4 .00 (101,6) Min.) B E C No. 18 Gauge Wire Amps A B C D E 3A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) 6A 3 .310 (84,1) 2 .000 (50,8) 1 .500 (38,1) 2 .940 (74,7) 2 .500 (63,5) 10A 4 .690 (119) 2 .250 (57,1) 1 .750 (44,4) 4 .063 (103,2) 3 .630 (92,2) 4 .10 (104,1) 3 .96 (100,5) F2800AA F2800BB (15Amp) Dimensions 3 .12 (79,25) 2 .00 (50,8) L I N E .65 Max . (16,51) L O A D 2 .00 (50,03) SINGLE PHASE FILTERS .188 Dia . (4,77) 2 Holes A High Performance L I N E 3 .54± .015 (89,9) .156 .56 (3,96) (14,22) .250 x .031 QC (6,35) x (,78) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 27 F5100 RFI Filters Ideal for Linear Power Supplies in Digital Equipment Features: • General Purpose Filter with Extended HighFrequency Insertion Loss Characteristics • Effective Suppression of Incoming Common Mode and Differential Mode Noise • Low-Profile Package with Integral IEC Connector • Available in 3, 6 and 10Amp Ratings 3A Part Number E78454 Termination Line/Load F5100CG03 IEC/ Solder Tab 6A F5100CG06 IEC/ Solder Tab 10A F5100CG10 IEC/ Solder Tab Maximum Leakage Current: Each Line to Ground F5100 115VAC, 60Hz: 0.25mA 250VAC, 60Hz: 0.50mA Agency Approvals: F5100 Simplified Schematic L L LOAD Nominal Current Rating Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A 10A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1400VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: C: IEC Receptacle G: Wire Wrap/Solder LINE SINGLE PHASE FILTERS Wide Band Specifications: G N N F5100 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 28 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5100CG (3, 6 and 10Amp) Dimensions Refer to Page 41 for Standard Mounting Cutouts L O A D L I N E .88 (22,35) 1 .97 (50,03) .59 (15,0) 2 .00 (50,80) Wide Band .130 Dia . (3,30) 2 Places 1 .575 (40,0) .80 (20,32) 1 .16 (29,46) SINGLE PHASE FILTERS F5101CG (3, 6 and 10Amp) Dimensions with attached mounting plate Refer to Page 41 for Standard Mounting Cutouts L O A D L I N E .26 (6,60) 2 .75 (69,85) 2 .85 (72,40) .59 (15,0) 2 .00 (50,80) .80 (20,32) 6-32 UNC-2B 6 Holes 1 .63 (41,40) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 29 F5200 RFI Filters Ideal for Linear Power Supplies in Digital Equipment Features: • General Purpose Filter with Extended HighFrequency Insertion Loss Characteristics • Effective Suppression of Incoming Common Mode and Differential Mode Noise • Low-Profile Package with Integral IEC Connector • Available in 3 and 6Amp Ratings 3A 6A Part Number E78454 Termination Line/Load F5200FG03 Fused IEC/ Solder Tab F5200FG06 Fused IEC/ Solder Tab F5200 Simplified Schematic L L LOAD Nominal Current Rating Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1400VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: F: Fused IEC Receptacle G: Wire Wrap/Solder Maximum Leakage Current: Each Line to Ground F5200 115VAC, 60Hz: 0.25mA 250VAC, 60Hz: 0.50mA Agency Approvals: LINE SINGLE PHASE FILTERS Wide Band Specifications: G N N F5200 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 30 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5200FG (3 and 6Amp) Dimensions Refer to Page 41 for Standard Mounting Cutouts L O A D L I N E 1 .140 (28,95) Max . .59 (14,93) Wide Band 2 .00 (50,80) .20 (5,08) 2 .79 (17,86) .125 (3,17) Dia. thru .218 (5,53) Dia. x 120° C’Sink 2 Holes 1 .73 (43,94) (1) 5mm x 20mm FUSE (NOT INCLUDED) 1 .296 (32,91) 1 .26 (32,0) SINGLE PHASE FILTERS 1 .42 (36,06) F5201FG (3 and 6Amp) Dimensions with attached mounting plate Refer to Page 41 for Standard Mounting Cutouts L O A D L I N E (1) 5mm x 20mm FUSE (NOT INCLUDED) .26 (6,60) 2 .75 (69,85) 2 .25 (57,15) 6-32 UNC-2B 6 Holes Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . 2 .00 (50,8) 2 .85 (72,40) 1 .296 (32,92) 1 .140 (28,96) Max .59 (15,0) 1 .26 (32,0) .06 (1,52) Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 31 F5500 RFI Filters Wide Band Specifications: Ideal for Linear and Switching Power Supplies • FCC and VDE Level “A” Applications • High Inductance Single Coil Design Provides High Common Mode and Differential Mode Performance Above 150KHz • High-Frequency Construction Techniques Maintain >50dB Insertion Loss from 10MHz to 1GHz • Compact, Space-Saving Package Available in 3, 6 and 10-Amp Ratings F5500 Simplified Schematic L LOAD L LINE SINGLE PHASE FILTERS Features: G N N Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 4A 10A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1400VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: C: IEC Receptacle G: Wire Wrap/Solder Maximum Leakage Current: Each Line to Ground F5500 115VAC, 60Hz: 0.25mA 250VAC, 60Hz: 0.50mA Agency Approvals: E78454 Nominal Current Rating Part Number Termination Line/Load 3A F5500CG03 IEC/ Solder Tab 6A F5500CG06 IEC/ Solder Tab 10A F5500CG10 IEC/ Solder Tab F5500 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 32 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5500CG (3, 6 and 10Amp) Dimensions E 1 .575 (40,01) B L O A D L I N E Wide Band A C 6-32 UNC-2B 2 Holes .59 (15,0) Refer to Page 40 for Standard Mounting Cutouts F5501CG (3, 6 and 10Amp) Dimensions with attached mounting plate 6-32 UNC-2B 6 Holes 3 .25 (82,55) .200 (5,08) 1 .375 (34,93) .200 (5,08) 2 .75 (69,85) Amps A B C D E 3A 2 .000 (50,8) 2 .000 (50,8) 1 .500 (38,2) .450 (11,4) .565 (14,3) 6A 2 .88 (73,1) 2 .13 (54,1) 1 .500 (38,2) .450 (11,4) .565 (14,3) 10A 2 .88 (73,1) 2 .13 (54,1) 1 .500 (38,2) .450 (11,4) .565 (14,3) L O A D L I N E .26 (6,60) 1 .75 (44,45) B A .59 (15,0) Refer to Page 41 for Standard Mounting Cutouts 2 .850 (72,40) .200 (5,08) C D Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . .750 (19,05) SINGLE PHASE FILTERS D Curtis Industries A Division of Powers Holdings, Inc . .56 (14,2) 1-800-657-0853 33 F5600 RFI Filters Features: • Suited for FCC “B” and VDE “A” Switching Power Supply Applications • High Inductance, Multi-Stage Design with High Common Mode and Differential Mode Insertion Loss for Switching Power Supply Emissions • >70dB Insertion Loss from 200KHz to 1GHz • Compact, Space-Efficient Package Available in 3 and 6Amp Ratings Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1400VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R .H . Termination: C: IEC Receptacle F: Fused IEC Receptacle G: Wire Wrap/Solder Termination: Quick Connect Maximum Leakage Current: Each Line to Ground F5600 115VAC, 60Hz: 0.50mA 250VAC, 60Hz: 1.20mA Agency Approvals: E78454 3A 6A Part Number F5600 Simplified Schematic Termination Line/Load F5600CG03 IEC/Solder Tab F5600FG03 Fused IEC/ Solder Tab F5600CG06 IEC/Solder Tab F5600FG06 Fused IEC/ Solder Tab L L LOAD Nominal Current Rating LINE SINGLE PHASE FILTERS Wide Band Specifications: G N N F5600 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 34 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5600CG (3 and 6Amp) Dimensions .565 (14,3) 1 .575 (40,01) 2 .13 (54,10) L O A D L I N E 6-32 UNC-2B 2 Holes Wide Band 1 .50 (38,10) 2 .88 (73,15) .59 (15,0) Refer to Page 40 for Standard Mounting Cutouts F5601CG (3 and 6Amp) Dimensions with attached mounting plate 6-32 UNC-2B 6 Holes 3 .25 (82,55) .2000 (5,08) 1 .375 (34,93) .200 (5,08) 2 .75 (69,85) Refer to Page 41 for Standard Mounting Cutouts L O A D L I N E .26 (6,60) 2 .13 1 .750 (54,10) (44,45) 2 .88 (73,15) .59 (15,0) .750 (19,05) 2 .850 (72,40) SINGLE PHASE FILTERS .45 (11,43) .200 (5,08) 1 .50 (38,2) .56 (14,2) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 35 F5700 RFI Filters Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 2A 6A 4A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1400VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: C: IEC Receptacle G: Wire Wrap/Solder Features: • Ideal for VDE “B” and MIL-STD-461 Switching Power Supply Applications • Very High Inductance Design with Differential Mode Choke to Provide Improved Performance Below 100KHz • Wide-Band Insertion Loss >60dB from 10MHz to 1GHz • Compact, Space-Efficient Package Available in 3 and 6Amp Ratings F5700 Simplified Schematic LOAD G N N Maximum Leakage Current: Each Line to Ground F5700 115VAC, 60Hz: 0.50mA 250VAC, 60Hz: 1.20mA Agency Approvals: E78454 Nominal Current Rating L L LINE SINGLE PHASE FILTERS Wide Band Specifications: Part Number Termination Line/Load 3A F5700CG03 IEC/ Solder Tab 6A F5700CG06 IEC/ Solder Tab F5700 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 36 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5700CG (3 and 6Amp) Dimensions .34 (8,63) .640 (16,25) 1 .575 (40,01) 2 .25 (57,15) L O A D L I N E Wide Band 1 .75 (44,45) 6-32 UNC-2B 2 Holes .59 (15,0) Refer to Page 40 for Standard Mounting Cutouts SINGLE PHASE FILTERS 45 .0 (11,43) 3 .75 (94,25) F5701CG (3 and 6Amp) Dimensions with attached mounting plate 6-32 UNC-2B 6 Holes .200 (5,08) L O A D L I N E 3 .25 (82,55) 13 .75 (34,93) .200 (5,08) 2 .75 (69,85) .26 (6,60) 3 .75 (95,25) 2 .25 (57,15) 2 .85 (72,40) 1 .75 (44,45) .750 (19,05) .59 (15,0) .200 (5,08) 1 .75 (44,45) Refer to Page 41 for Standard Mounting Cutouts .48 (12,19) .45 (11,43) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 37 F5900 RFI Filters Specifications: Wide Band Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1 .5A 6A 4A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VDC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max . at rated current Humidity Range: 0% to 95% R .H . Termination: C: IEC Receptacle F: Fused IEC G: Wire Wrap/Solder J: Switched IEC Maximum Leakage Current: Each Line to Ground F5900 115VAC, 60Hz: 0.50mA 250VAC, 60Hz: 1.20mA Agency Approvals: • High Performance Filter Designed for Switching Power Supply Emissions • >70dB Insertion Loss from 200KHz to 1GHz • Integral Power Switch and 5 x 20mm Fuse Holder • Available in 3 and 6Amp Versions with Optional Mounting Faceplates E78454 F5900 Simplified Schematic with Switch F5900 Simplified Schematic without Switch L N N L LOAD G LINE L LOAD L LINE SINGLE PHASE FILTERS Features: G N N F5900 SERIES TYPICAL COMMON MODE INSERTION LOSS — dB (50 OHM CIRCUIT) 0 –20 –40 dB –60 –80 –100 .01 38 www .curtisind .com .1 1.0 10 FREQUENCY in MHz Curtis Industries A Division of Powers Holdings, Inc . 100 1000 Specifications subject to change. Dimensions are shown for reference purposes only . F5900CG .59 (14,98) (3 and 6Amp) Dimensions .45 (11,43) L O A D 2 .49 (63,24) Max . Refer to Page 42 for Standard Mounting Cutouts L I N E 8-32 UNC-2B 4 Holes 1 .332 (33,83) F5900FG (3 and 6Amp) Dimensions .299 (75,94) Refer to Page 42 for Standard Mounting Cutouts .45 (11,43) 3 .02 (76,70) Max . .59 (14,93) 1 .93 (49,02) Max . Nominal Current Rating 3A 2 .55 (64,77) Max . L I N E 1 .300 (33,02) 6-32 UNC-2B 6 Holes 1 .300 (33,02) .200 .800 (5,08) (20,32) 6A 3 .00 (76,20) .450 (11,43) Part Number Termination Line/Load F5900CG03 IEC/Solder Tab F5900FG03 Fused IEC/Solder Tab F5900JG03 Switched IEC/Solder Tab F5900CG06 IEC/Solder Tab F5900FG06 Fused IEC/Solder Tab F5900JG06 Switched IEC/Solder Tab 3 .02 (76,70) Max . .59 (14,98) 1 .93 (49,02) Max . SINGLE PHASE FILTERS L O A D 3 .87 (98,29) .840 (21,33) 3 .02 (76,70) Max Wide Band 1 .93 (49,02) Max . 1 .312 (33,32) ± .016 L O A D 1 .875 (47,49) .200 (5,08) .800 (20,32) 2 .55 (64,77) Max . L I N E (1) 5mm x 20mm Fuse (not included) 3 .87 (98,29) F5900JG (3 and 6Amp) Dimensions Refer to Page 42 for Standard Mounting Cutouts (1) 5mm x 20mm Fuse (not included) 1 .300 (33,02) 6-32 UNC-2B 6 Holes 1 .300 (33,02) 2 .00 .800 (50,80) (20,32) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . 3 .00 (76,20) 1 .875 (47,49) Curtis Industries A Division of Powers Holdings, Inc . .800 (20,32) 2 .00 (50,80) 1-800-657-0853 39 Standard Mounting Cutouts F1200CA, F1250CA, F1299CA, F1300CA, F1399CA, F1400CA, F1500CA, F1600CA, F1700CA F1500FA, F1600FA, .638 (16,21) 1 .20 (30.5) .187 (4,75) .140 Dia . (3,55) 2 Holes .90 (22,9) 1 .575 (40,0) .234 (5,94) ✱ .09 R (2,29) .140 Dia . (3,55) 2 Holes 1 .275 (32,39) 1 .145 (29,08) ✱ for mounting from back side 1 .417 (36,0) .450 (11,43) SINGLE PHASE FILTERS How to Order The Curtis part numbering system is made up of four elements. Each element denotes a specific requirement (mechanical or electrical) which, when properly sequenced, fully identifies the required catalog filter. As shown, the first five alpha/numeric characters denote the series type; the sixth character (alpha) denotes the type of line termination; the seventh character (alpha) denotes the type of load termination; the last two characters (numeric) denote the current rating. Compose your part number as follows: Select the series required, add two alpha character for the line and load termination, followed by two numeric characters for the required current rating . For example, F1100AB06 completely identifies an F1100 series filter with quick connects on line side and wire leads on load side, with a 6-amp rating. F1100 X X SERIES LINE TERMINATION A = Quick Connects B = Wire Leads C = IEC Connector D = Screw Terminals (20 & 30 amp only) F = Fused IEC P = Printed Circuit Pins W= Dual Fused IEC J = Switched IEC 40 www .curtisind .com LOAD TERMINATION A = Quick Connects B = Wire Leads D = Screw Terminals (20 & 30 amp only) P = Printed Circuit Pins G= Solder Tab X CURRENT RATING 01 = 1 Amp 03 = 3 Amps 06 = 6 Amps 10 = 10 Amps 15 = 15 Amps 20 = 20 Amps 30 = 30 Amps F1300CP, F1350CP, F1600CP .600 (15,2) 1 .500 (38,1) N .700 (17,8) 1 .400 (35,6) .062 Hole Dia . (1,57) 5 Holes L F5500/5600/5700 SERIES 1 .575 (40,01) .90 (22,8) .140 Dia . (3,55) 2 Holes .234 R . (5,94) (Typ.) Curtis Industries A Division of Powers Holdings, Inc . 1 .20 (30,48) Specifications subject to change. Dimensions are shown for reference purposes only . F5100 SERIES F5200, F5600FG SERIES 1 .575 (40,01) 1 .420 (36,06) ± .004 .410 (10,41) .820 (20,83) .140 Dia . (3,56) 2 Holes .637 (16,18) 1 .20 (30,48) .032 R . (,81) Max . F5101 SERIES .500 (12,7) 1 .000 (25,4) F5201, F5601FG SERIES 2 .35 (59,69) 2 .350 (59,69) .25 R . (6,35) (Typ.) 1 .375 (34,93) .467 (11,86) .612 (15.54) .12 R . (3,05) (Typ.) .465 (11,81) 1 .000 (25,4) .930 (23,62) 2 .000 (50,8) 1 .000 (25,4) .500 (12,70) 1 .000 (25,4) .12 R . (3,05) (Typ.) .875 (22,23) 1 .425 (36,20) .925 (23,50) .09 R . (2,29) (Typ.) 1 .400 (35,56) .925 (23,50) 1 .812 (46,02) .25 R (6,35) (Typ.) .250 (6,35) .700 (17,78) .156 R . (3,96) (Typ.) 1 .062 (26,97) .269 (6,83) 2 .000 (50,80) (3,96) 6 Holes 1 .417 (36,0) .156 Dia . (3,96) 6 Holes .612 (15.54) .150 Dia . (3,81) 6 Holes F5501/5601CG/5701 SERIES .156 Dia . 1 .145 (29,08) + .012 –.000 .57 (14,47) .375 (9,53) SINGLE PHASE FILTERS 1 .575 (40,0) .787 (2,0) .140 Dia . (3,55) 2 Holes 1 .275 (32,38) + .012 –.000 1 .175 (29,85) .930 .465 (23,62) (11,81) 1 .175 (29,85) 1 .750 (44,45) 2 .850 (72,39) NOTE: Tolerance for all dimensions unless otherwise specified: .XXX three place ± .004, .XX two place ± 0 .10 Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents . Curtis Industries A Division of Powers Holdings, Inc . 1-800-657-0853 41 Standard Mounting Cutouts F5900FG .800 (20,32) 1 .812 (46,02) 1 .875 (47,62) 2 .600 (66,04) 1 .062 (26,97) .906 (23,01) .531 (13,48) .09 R . (2,28) (Typ.) .156 Dia . (3,96) 6 Holes F5900CG .334 (8,48) .550 (12,70) .25 R . (6,35) (Typ.) 1 .300 (33,02) .156 R . (3,96) (Typ.) .330 (8,38) SINGLE PHASE FILTERS .800 (20,32) .700 (17,78) 1 .400 (35,56) 2 .00 (50,80) 1 .332 (33,78) 1 .00 (25,40) .12 R . (3,04) (Typ.) .930 (23,62) .187 Dia . (4,75) 4 Holes F5900JG .800 (20,32) 1 .875 (47,62) 1 .062 (26,97) .465 (11,81) 1 .312 (33,32) .656 (16,66) .800 (20,32) 1 .812 (46,02) .906 (23,01) .531 (13,48) .330 (8,38) .156 Dia . (3,96) 6 Holes .09 R . (2,28) (Typ.) .156 R . (3,96) (Typ.) .480 (12,19) .960 (24,38) 2 .600 (66,04) 1 .300 (33,02) .700 (17,78) 1 .400 (35,56) 2 .600 (66,04) NOTE: Tolerance for all dimensions unless otherwise specified: .XXX three place ± .004, .XX two place ± 0 .10 42 www .curtisind .com Curtis Industries A Division of Powers Holdings, Inc . Specifications subject to change. Dimensions are shown for reference purposes only . POWER ENTRY MODULES ] General Purpose Combination Curtis Industries A Division of Powers Holdings, Inc. 43 F2199/F2200 RFI Filters • General Purpose Filters — Designed for Common Mode Emissions or Susceptibility Applications • Integral IEC Connector in Space-Efficient Package F2199/F2200 Simplified Schematic Specifications: L Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 1A 1A 3A 3A 6A 6A 10A 8A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F2199/F2200 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: LOA D L G N N F2200CA (1, 3 and 6Amp) Dimensions .881 (22,4) 1.575 1.98 (40,0) (50,29) Max. L I N E L O 1.145 A (29,08) D 1.555 (39,5) .550 (13,97) .133 Dia. (3,38) 2 Holes POWER ENTRY MODULES Refer to Page 58 for Standard Mounting Cutouts • Ideal for Linear Power Supplies in Digital Equipment LIN E General Purpose Filtered Modules Features: .250 QC (6,4) .805 (20,45) F2199CA (1, 3, 6 and 10Amp) Dimensions 20.80max (0.819) Ø6.6 (0.26) 90°CS 40.00+.35 (1.575+.014) Nominal Current Rating 1A 3A 6A 10A Ø3.35 (0.132) 54.50max (2.146) 6.35(0.25) faston terminal with Ø1.78(0.070) hole (slotted hole for ground) Part Number Termination Line/Load 28.2max (1.110) 50.30max (1.980) E78454 73780 72031376 099523 72102892 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 F2199CA01 IEC/QC Common Differential 32 5 45 14 45 23 43 47 43 50 40 45 F2200CA01 IEC/QC Common Differential 22 — 35 2 40 3 46 35 50 40 50 40 F2199CA03 IEC/QC Common Differential 20 5 30 12 38 14 48 38 48 44 44 42 F2200CA03 IEC/QC Common Differential 15 — 25 2 30 3 45 35 50 40 50 40 F2199CA06 IEC/QC Common Differential 9 5 20 12 28 14 42 33 50 42 47 42 F2200CA06 IEC/QC Common Differential 9 — 20 2 25 7 41 28 45 46 50 57 F2199CA10 IEC/QC Common Differential 3 5 13 12 20 16 35 20 40 28 45 40 NOTE: Other combinations of terminals may be specified on special order. 44 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F2300 RFI Filters Specifications: Features: • Effective Protection from Pulsed, Intermittent or Continuous RFI for FCC “A” Applications • High-Performance Low-Leakage Filter in Low Profile Package with Integral IEC Connector • Increased Inductance and Line-to-Line Capacitance Provide Enhanced Common Mode and Differential Mode Attenuation E78454 General Purpose Filtered Modules Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 6A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F2300 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: 064179 72031376 L LOAD LINE L POWER ENTRY MODULES F2300CA Simplified Schematic G N N .881 (22,4) F2300CA (6Amp) Dimensions L I N E 1.575 1.980 (40,0) (50,29) Max. Refer to Page 58 for Standard Mounting Cutouts 6A Part Number Termination Line/Load F2300CA06 IEC/QC 1.180 (29,9) 2.910 (73,9) .133 Dia. (3,38) 2 Holes Nominal Current Rating L O A D .550 (14) .805 (20,45) MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Common Differential .15 .50 25 12 37 30 Frequency - MHz 1.0 5.0 45 50 45 65 10 30 45 65 45 60 NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 45 Features: • Higher Performance Filters Designed for Common Mode and Differential Mode Applications • 4X Greater Differential Mode Insertion Loss at 1 MHz than F2199/F2200 Series with No Increase in Physical Size • Especially Suited for Use with Linear Power Supplies and FCC “A” Applications F2400/2500 Simplified Schematic L LOAD L LINE POWER ENTRY MODULES General Purpose Filtered Modules F2400/2500 RFI Filters G N N Specifications: Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 1.5A 6A 3A 10A 10A 15A 10A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F2400/F2500 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: E78454 Nominal Current Rating Part Number 3A F2400CA03 F2500CA03 IEC/QC IEC/QC 6A F2400CA06 F2500CA06 10/15A F2400CA10 F2400CA15 Termination Line/Load 73780 (10/15A Only) 72031376 MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Frequency - MHz 1.0 5.0 .15 .50 10 30 Common Differential 22 8 35 18 40 24 46 40 50 50 50 40 IEC/QC IEC/QC Common Differential 15 8 24 18 31 24 42 40 45 50 50 40 IEC/QC IEC/QC Common Differential 4 2 10 8 13 15 28 30 35 35 40 35 NOTE: Other combinations of terminals may be specified on special order. 46 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F2400CA (3, 6, 10 and 15Amp) Dimensions 1.38 (35,1) 1.99 (50,5) L I N E L O A D General Purpose Filtered Modules 1.575 (40,0) 1.18 (29,5) 1.81 (46,0 ) Ø .13 (3,3) Refer to Page 58 for Standard Mounting Cutouts 1.95 (49,5) .88 (22,4) .83 (22,8) .250 QC (6,4) 1.575 (40,0) 1.980 (50,29) Max. L I N E L O 1.16 A (29,5) D 1.575 (40,0) .133 QC (3,38) 2 Holes POWER ENTRY MODULES F2500CA (3 and 6Amp) Dimensions .250 QC (6,4) .650 (16,5) .790 (20,1) Refer to Page 58 for Standard Mounting Cutouts Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 47 F2600 RFI Filters Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect F: Fused IEC J: Switched IEC P: PCB Pins W: Dual Fused IEC Maximum Leakage Current: Each Line to Ground F2600 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: Features: • General Purpose “L-Type” Circuit Effective in Reducing Both Incoming and Outgoing Powerline Noise Levels in FCC “A” Applications • Integral 5 X 20mm Single or Dual Fused IEC Connector • Optional SST Switched IEC Connector • All Series Available in Labor-Saving PC Mounted Case Style E78454 064179 72031310 F2600F Simplified Schematic L LOAD L LINE POWER ENTRY MODULES General Purpose Filtered Modules Specifications: G N Nominal Current Rating Part Number 3A F2600FA03 F2600FP03 Fused IEC/QC Fused IEC/PC 6A F2600FA06 F2600FP06 3A N MINIMUM INSERTION LOSS - dB (50 ohm Circuit) Termination Line/Load MODE Frequency - MHz 1.0 5.0 .15 .50 10 30 Common Differential 21 8 35 18 41 24 50 40 50 50 50 40 Fused IEC/QC Fused IEC/PC Common Differential 18 8 34 18 41 24 45 40 45 50 45 50 F2600WA03 F2600WP03 Dual Fused IEC/QC Dual Fused IEC/PC Common Differential 21 8 35 18 41 24 45 40 45 50 50 40 6A F2600WA06 F2600WP06 Dual Fused IEC/QC Dual Fused IEC/PC Common Differential 18 8 34 18 41 24 40 40 40 50 45 50 3A F2600JA03 F2600JP03 Switched IEC/QC Switched IEC/PC Common Differential 21 8 35 18 41 24 45 40 45 50 50 40 6A F2600JA06 F2600JP06 Switched IEC/QC Switched IEC/PC Common Differential 18 8 34 18 41 24 40 40 40 50 45 50 NOTE: Other combinations of terminals may be specified on special order. 48 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F2600FA (3 and 6Amp) Dimensions .20 (5,0) L O A D 1.140 (28,9) 2.000 (50,8) 1.730 (43,9) Refer to Page 58 for Standard Mounting Cutouts .550 (13,9) L I N E .20 (5,0) 1.260 (32,0) 1.296 (32,9) .200 REF (5,0) 2.20 (55,9) 1.730 (43,9) 2.75 (69,8) 1.140 (28,9) 1.260 (32,0) 1.296 (32,9) LOAD 1.420 (36,0) 1.420 (36,0) (1) 5mm x 20mm Fuse (not included) .210 (5,3) F2600WA (3 and 6Amp) Dimensions L I N E F2600W Simplified Schematic L G N N 2.000 (50,8) 1.8 (5,0) Max. 1.140 (28,9) .550 (13,9) POWER ENTRY MODULES LOAD LINE L L O A D 2.75 (69,8) 1.736 (44,0) 1.260 (32,0) 1.339 (34,0) 1.420 (36,0) (2) 5mm x 20mm Fuses (not included) F2600JA (3 and 6Amp) Dimensions L I N E F2600J Simplified Schematic L LOAD LINE L G N N .17 (5,0) L O A D 2.000 (50,8) .550 (13,9) 1.260 (32,0) 1.339 (34,0) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. 1.140 (28,9) 2.75 (69,8) 1.736 (44,0) 1.420 (36,0) General Purpose Filtered Modules L I N E F2600FP (3 and 6Amp) Dimensions SPST Switch Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 49 F2700 RFI Filters Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 2A 6A 4A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect B: Wire C: IEC Receptacle F: Fused IEC Maximum Leakage Current: Each Line to Ground F2700 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Agency Approvals: Features: E78454 064179 72031308 F2700 Without Switch or Fuse Simplified Schematic L LOAD L LINE • Designed for FCC “B” and VDE “B” Switching Power Supply Applications • Very High Inductance Design with Differential Mode Choke to Provide Improved Performance Below 100KHz • Compact, Space-Efficient Package Available in 3 and 6Amp Ratings • Also Available with Integal Fused IEC Connector and “ON/OFF” Power Switch G N N F2700 With Switch and Fuse Simplified Schematic L LOAD L LINE POWER ENTRY MODULES General Purpose Filtered Modules Specifications: G N N Nominal Current Rating 3A 6A Part Number MINIMUM INSERTION LOSS - dB (50 ohm Circuit) Termination Line/Load MODE .01 .02 Frequency - MHz .05 .15 .50 1.0 5.0 10 30 F2700AA03 QC/QC Common Differential 20 5 27 27 36 52 45 70 42 70 42 70 42 70 40 60 38 58 F2700CA03 F2700FB03 IEC/QC Fused IEC/Wire Common Differential 20 5 27 27 36 52 45 70 42 70 42 70 42 70 40 60 38 58 F2700AA06 F2700CA06 QC/QC IEC/QC Common Differential 10 5 18 20 28 48 39 70 42 70 45 70 45 70 45 70 45 65 NOTE: Other combinations of terminals may be specified on special order. 50 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F2700AA (3 and 6Amp) Dimensions A D L O A D L I N E F B E F C .250 QC (6,4) Amps A B C D E F 3A 3.315 (84,2) 2.000 (50,8) 1.500 (38,1) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 6A 4.440 (112,8) 2.250 (57,2) 1.750 (44,5) 4.063 (103,2) 3.620 (91,9) .550 (14,0) F2700FB03 (3Amp) Dimensions 2.130 (54,10) 5mm x 20mm FUSE (NOT INCLUDED) 3.020 (76,7) Max. POWER ENTRY MODULES Refer to Page 58 for Standard Mounting Cutouts .294 (7,46) (2) 8-32 x .3 UNC2B 1.312 (33,32) L O A D L I N E 2.490 (63,29) Max. 1.930 (49,02) Max. General Purpose Filtered Modules .188 Dia. (4,77) 2 Holes 5.00 Min. (Typ.) No. 18 Gauge Wire F2700CA (3 and 6Amp) Dimensions E L O A D L I N E (2) 6-32 UNC2B A C Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. B D .250 QC (6,4) Refer to Page 58 for Standard Mounting Cutouts Amps A B C D E 3A 2.880 (73,2) 2.125 (54,0) 1.719 (43,6) .550 (14,0) .575 (14,6) 6A 3.750 (95,2) 2.250 (57,1) 1.750 (44,4) .550 (14,0) .640 (16,29) Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 51 FPE7/FPE8 Series Specifications: POWER ENTRY MODULES Combination Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 6A Current Overload: 6X for 8 Seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at Rated Current Humidity Range: 0% to 95% R.H. Termination: • IEC Receptacle • Wire Wrap/Solder Maximum Leakage Current: Each Line to Ground PE7, PE 8, PE9 115VAC, 60Hz: 0.25mA 250VAC, 50Hz: 0.40mA Voltage Select Card: Installed in 120VAC position unless otherwise specified Agency Approvals: E78454 Features: 064179 72031305 Refer to Page 55 for Ordering Instructions • RFI Filter Module Combines IEC Connector, Fusing, and Voltage Select Features in One Unit • FPE7 Series Filters Provide 20% More Differential Mode Attenuation Than Comparable Units • Accepts Either U.S. or European Standard Fuse Sizes FPE7 Series Simplified Schematic FUSING LINE G L SERIES-SERIES 110-220240 V VOLTAGE SELECTOR 1-POLE B A a b G FOR TRANSFORMERS WITH TAP LOAD C A C 240V 220V c D D N Voltage Contacts 110V b,e 220V b,c 240V a d H F E e 2-POLE E F 2a 110V G Nominal Current Rating Part Number LINE L Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) FUSING MODE 1-POLE 100-120220-240 V VOLTAGE SELECTOR G B 3A FPE7XXX03 FPE8XXX03 G IEC/Solder Tabs Common Differential 6A FPE7XXX06 N FPE8XXX06 IEC/Solder Tabs Common H Differential F LOAD .50 .15 a b c A 18 8 C A C24 SERIES-PARALLEL Frequency - MHz FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 1.0 5.0 10 120V 100V 18 D D d e 2-POLE 10 8 E 19 E 18 120V F G 52 www.curtisind.com LINE L Curtis Industries G B a A B A Voltage Contacts 100V 39 a,c,e 120V 39 b,c,e 220V a,d 240V b,d SERIES-PARALLEL LOAD 115-230 V VOLTAGE SELECTOR 1-POLE 24 24 45 46 45 50 50 40 44 40 50 40 Specifications subject to change. Dimensions are shown for reference purposes only. A Division of Powers Holdings, Inc. FUSING 30 24 30 FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 115V NL e F 2-POLE b G E A F C 2a D G a C c D d H N E e F FUSING FPE7 Series Simplified Schematic G L B A b G FUSING LINE 1-POLE HG NL C D B F e 2-POLE a SERIES-PARALLEL LOAD b G 100V FOR TRANSFORMERS WITH TWO SEPARATE Voltage Contacts WINDINGS D E A 120V E A F C C 120V 100V c GD D d H N 120V E e F E F 2-POLE G FUSING LINE G L B b G FUSING LINE 1-POLE HG NL C c 115-230 V VOLTAGE SELECTOR d D B F 2-POLE e a b G 115V SERIES-PARALLEL LOAD D E B E A F C A C Voltage Contacts 100V a,c,e 120V b,c,e 220V a,d 240V b,d FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS B A C A a a,c,e b,c,e a,d b,d FOR TRANSFORMERS WITH TWO SEPARATE Voltage Contacts WINDINGS 115V 115V 115V 230V a,b d,e c Combination 1-POLE 100V 120V 220V 240V SERIES-PARALLEL LOAD 115-230 V VOLTAGE SELECTOR Voltage Contacts 110V b,e 220V b,c 240V a 120V A C c 100-120220-240 V VOLTAGE SELECTOR d b,c a FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS LOAD a 220V 240V SERIES-PARALLEL G 100-120220-240 V VOLTAGE SELECTOR 1-POLE 110V E F 2a 2-POLE LINE 220V c GD D d H N e E E F 2-POLE Voltage Contacts 115V a,b d,e 230V c POWER ENTRY MODULES FPE8 Series Simplified Schematic F 115V G LINE ROCKER SWITCH FUSING 1-POLE G L 1-POLE 1 1a LOAD L G H N 2-POLE 2 2a N 2-POLE G Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 53 FPE7/FPE8 Series (continued) FPE7/FPE8 Snap-Mount Series (3 and 6Amp) Dimensions Refer to Page 55 for Standard Mounting Cutouts 1.260 (32,0) 2.266 (57,55) 1.051 (26,70) .22 (5,5) POWER ENTRY MODULES Combination 2.283 (58,0) LI NE .100 (2,7) Q.C. Terminals All Locations LOAD 1.091 (27,71) FPE7/FPE8 Screw-Mount Series (3 and 6Amp) Dimensions 1.969 (50,0) Refer to Page 55 for Standard Mounting Cutouts 2.266 (57,55) 1.575 (40,0) .22 (5,5) 1.051 (26,70) 1.142 (29,0) 2.283 (58,0) LINE 54 www.curtisind.com .126 (3,20) Dia. Holes .100 (2,7) Terminals Except Switch Curtis Industries A Division of Powers Holdings, Inc. L OAD 1.091 (27,71) Specifications subject to change. Dimensions are shown for reference purposes only. How to Order FPE7 FPE8 X X X X X SERIES FPE= Power Entry CURRENT RATING 3 = 3 AMP 6 = 6 AMP OPTIONS (Consult Factory) 0 = Standard Units SWITCH 0 = No Switch 1 = SPST Rocker Switch w/Q.C. 2 = DPST Rocker Switch w/Q.C. VOLTAGE SELECTOR 0 = No Selector (FPE80 Series) 1 = 110-220-240 VAC 2 = 100-120-220-240 VAC 3 = 115-230 VAC 2.20 (55,9) 1.10 (27,9) 2.20 (55,9) 1.575 (40,0) 1.122 (28,50) 1.122 (28,50) *Panel Thickness FPE7/FPE8 Screw Mount Series .08 R (2,0) *See Below FPE7/FPE8 To change fuse, remove power cord and open the front cover on the module. Remove fuse holder and replace fuse. Reinsert fuse holder and close cover. To change the operating voltage on the FPE7 Series, remove the power cord and open front cover. Rotate voltage select wheel until desired voltage appears in window of cover. • Filter shipped without fuse. Always use caution when selecting and changing fuses and voltage requirements. Curtis Industries is not responsible for malfunction due to improper installation/selection of fuse and/or voltage select. Cutout .031" - .079" use 2.20" .080" - .125" use 2.22" Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. POWER ENTRY MODULES FPE7/FPE8 Snap-Mount Series INSTALLATION INSTRUCTION IMPORTANT – CHANGING FUSE/VOLTAGE Combination MOUNTING METHOD & FUSING 0 = Snap Mount Metric Fuse 1 = Snap Mount US Fuse 2 = Snap Mount 2 Metric Fuses 3 = Snap Mount 2 US Fuses 6 = Screw Mount Metric Fuse 7 = Screw Mount U.S. Fuse 8 = Screw Mount 2 Metric Fuses 9 = Screw Mount 2 U.S. Fuses 4-40 (M3) .08 R (2,0) Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 55 FPE1 Series E78454 3 4 064179 72031202 FUSING 1 POLE 1 LINE 2 L 3 4 N N 2 POLE G G FPE1 Series Simplified Schematic with Voltage Selector FUSING 1 POLE L L 1 N FPE1XXXP0 G 2 POLE MODE .05 .15 1 IEC/QC Common Differential 10 10 202 IEC/QC Common Differential 13 10 4 24 20 NOTE: Other combinations of terminals may be specified on special order. www.curtisind.com LOAD MINIMUM INSERTION LOSS - dB (50 ohm Circuit) L LOAD FPE1XXX10 L IN E 10A 1 POLE 110V 4 2 POLE G Part Termination Number FUSING Line/Load L 3 N G Nominal Current Rating 110V 2 N 56 2 2 POLE G G L FPE1 Series Simplified Schematic without Voltage Selector 1 LOAD • RFI Filter Module Combines IEC Connector, Fusing, Optional Voltage Select and On/Off Switch into a Single, Space-Efficient Assembly • Enhanced Low Frequency Response with No Resonant Peaks • Fully Shielded for Radiative Noise Control • Accepts Either U.S. or European Standard Fuse Sizes. Dual or Single Power Line Fusing LINE Features: Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 10A 10A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 2250VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: • QC – Quick Connect • IEC Receptacle Maximum Leakage Current: FUSING Each Line to Ground PE1 PE1-PO1 POLE L 0.25mA 0.4mA L 115VAC, 60Hz: 250VAC, 50Hz: 0.40mA .75mA Voltage Select Card: Installed in 120VAC position unless otherwise specified N N Agency Approvals: LIN E POWER ENTRY MODULES Combination Specifications: 20 3 N Frequency - MHz .50 1.0 5.0 10 30 30 30 38 35 45 55 50 60 50 55 33 30 38 35 48 65 54 65 54 55 G Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. 1 1 FPE1 1.99 (50,5) (10Amp) Dimensions L I N E Refer to Standard Mounting Cutouts on Page 58 L O A D 2.41 (61,2) Max. 1.12 (28,4) 3.00 (76,2) 2.58 (65,5) Max. 1 3 2 1.15 (29,2) Max. 3.20 (81,3) WITH VOLTAGE SELECTOR How to Order FPE1 X X X X X SERIES FPE= Power Entry CURRENT RATING 0 = 10 AMP OPTIONS (Consult Factory) 1 = Standard Units P = High Performance Insertion Loss SWITCH 0 = No Switch 1 = SPST Rocker Switch 2 = DPST Rocker Switch VOLTAGE SELECTOR 0 = No Selector 3 = 115-230 VAC Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. INSTALLATION INSTRUCTION IMPORTANT – CHANGING FUSE/VOLTAGE FPE1 To change fuse, remove power cord. Remove voltage selector and replace fuse. Reinsert fuse holder. To change the operating voltage on the FPE1 Series, remove the power cord and rotate fuse holder block until desired voltage aligns with the mark on the module housing. • Filter shipped without fuse. Always use caution when selecting and changing fuses and voltage requirements. Curtis Industries is not responsible for malfunction due to improper installation/selection of fuse and/or voltage select. 1-800-657-0853 POWER ENTRY MODULES MOUNTING METHOD & FUSING 6 = Screw Mount Metric or U.S. Fuse* 8 = Screw Mount 2 Metric or U.S. Fuses * U.S. Fuse not available without voltage selector Combination H 1.575 (40,01) 4 57 Standard Mounting Cutouts F2199CA, F2200CA, F2300CA, F2400CA, F2500CA, F2700CA, F3100CA, F3200CA, F3400CA, F3500CA .187 (4,75) 1.20 (30,5) .140 Dia. (3,55) 2 Holes .140 Dia. (3,55) 2 Holes .820 (20,8) 1.575 (40,0) .062 R. (1,57) 1.20 (30.5) .187 (4,75) .410 (10,4) .90 (22,9) 1.575 (40,0) .234 (5,94) Back Mounting Front Mounting F2600FP, F3300FP F2600, F3300 .062 Dia. (1,57) 5 Holes POWER ENTRY MODULES .450 (11,43) .638 (16,21) .300 (7,62) .600 (15,24) .140 Dia. (3,55) 2 Holes *.09 R (2,29) or **.03 R (.076) 1.275 (32,39) 1.145 (29,08) .925 (23,5) * for mounting from backside ** F2600, F3300 for mounting from front side use .03 R vs. .09 R 1.417 (36,0) F2700FB 2.821 (71,65) .700 (17,78) 1.812 (46,02) .906 (23,01) .531 (13,49) 1.421 (36,09) .750 (19,05) .219 (5,56) .187 (4,75) .094 (2,39) 1.20 (30,6) R.03 Max. 1.062 (26,97) 1.500 .531 (38,10) (13,49) .09 R. (2.28) (Typ.) .156 R. 1.062 (3,96) (26,97) (Typ.) FPE1 Screw Mount Series +.02 2.41 –0 (61,2) M3 +.02 1.15 –0 (29,2) 1.575 ±.005 (40,0) 58 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. THREE-PHASE FILTERS Curtis Industries A Division of Powers Holdings, Inc. ] 59 Series F3480/F3600 Specifications: Rated Voltage: 480 VAC - 50/60 Hz 600 VAC - 50/60 Hz Rated Current: 480 VAC - 9A to 608A 600 VAC - 8A to 600A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): 480VAC Line to Ground 2210 VDC Line to Line 2780 VDC 600VAC 3150 VDC 3150 VDC Insulation Resistance: 1000 MΩ min. at 250 VDC Ambient Temperature: 0°C to 40°C (32°F to 104°F) Humidity Range: 0% to 95% R.H. Termination: • Wire • Terminal Blocks • Pressure Terminal Blocks Weight: 3 to 65lbs (1.36 to 29.50kg) Agency Approvals: THREE-PHASE FILTERS E78454 Designed to attenuate conducted interference in a small package providing excellent insertion loss, the F3480/F3600 series filters will provide effective EMC solutions up to 600A at 600VAC and power applications up to 360kVA. With effective noise suppression in the critical 150kHz-30MHz range, this advanced 2-stage filter line will support both Delta and Wye connected loads. Curtis three phase filters are designed to provide EMC solutions in many applications such as: - Motor - Motor Control Centers - Facility Filters - Uninterruptible Power Supplies - Power Conditioning Units - Laser Welders - Automated Test Equipment - Robotics - CNC Machinery - Elevators - Industrial Ovens F3480 Simplified Schematic A A B B C C G G LINE F3600 Simplified Schematic A A B B C C N N G LINE 60 www.curtisind.com LOAD Curtis Industries A Division of Powers Holdings, Inc. G LOAD Specifications subject to change. Dimensions are shown for reference purposes only. 3-Phase Power Line Filters Ordering Information: F3600 T 600 3-Phase Series: F3480 = 480 VAC F3600 = 600 VAC Current Rating 008 - 608 (Refer to Charts) T = Terminal Blocks B = Wire Leads A = .250 Q.C. Terminal (8 - 50A Only) F3480 Series - 480 VAC Rated Current (Amps) 608A 322A 135A 112A 80A 60A F3480T608 F3480B608 F3480T322 F3480B322 F3480T185 F3480B185 F3480T136 F3480B136 F3480T112 F3480B112 F3480T080 F3480B080 F3480T060 F3480B060 140mA 90mA 90mA 80mA 80mA 30mA 30mA 50A F3480A050 F3480B050 F3480T050 15mA 32A F3480A032 F3480B032 F3480T032 7mA 16A F3480A016 F3480B016 F3480T016 3mA 9A F3480A009 F3480B009 F3480T009 3mA Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Dimensions (Inches) Minimum Insertion Loss (dB) CM DM .15 60 30 .5 70 40 CM DM .15 60 30 .5 70 40 CM DM .15 60 30 .5 70 35 CM DM .15 60 25 .5 65 35 CM DM .15 60 25 .5 65 35 CM DM .15 60 15 .5 70 25 CM DM .15 60 15 .5 70 25 CM DM .15 60 10 .5 75 40 CM DM .15 60 10 .5 70 45 CM DM .15 50 10 .5 70 50 CM DM .15 60 30 .5 80 45 Frequency (MHz) 1 5 70 60 40 35 Frequency (MHz) 1 5 70 65 40 40 Frequency (MHz) 1 5 70 65 35 45 Frequency (MHz) 1 5 70 60 45 30 Frequency (MHz) 1 5 70 60 45 30 Frequency (MHz) 1 5 70 65 45 40 Frequency (MHz) 1 5 70 65 45 40 Frequency (MHz) 1 5 80 75 50 50 Frequency (MHz) 1 5 80 75 50 50 Frequency (MHz) 1 5 80 75 50 40 Frequency (MHz) 1 5 80 70 50 50 10 45 30 30 30 20 10 55 35 30 45 20 10 55 40 30 45 30 10 50 30 30 40 20 10 50 30 30 40 20 10 55 40 30 45 30 10 55 40 30 45 30 10 70 50 30 50 40 10 65 50 30 45 40 10 65 40 30 50 40 10 60 50 30 50 50 A B C D E F G 18.75 5.25 5.93 41.25 18.75 5.25 4.50 -- 16.00 8.00 .28 x .40 10.50 5.25 4.63 23.50 8.00 4.00 .28 x .40 10.50 5.25 4.50 -- 11.25 4.12 4.25 20.25 11.25 4.12 3.50 -- 10.00 5.00 .20 x .30 8.50 4.12 4.25 16.00 8.50 4.12 3.50 -- 7.00 3.50 .20 x .30 8.50 4.12 4.25 16.00 7.00 3.50 .20 x .30 8.50 4.12 3.50 -- 8.50 4.12 4.25 16.00 8.50 4.12 3.50 -- 7.00 3.50 .20 x .30 8.50 4.12 4.25 16.00 7.00 3.50 .20 x .30 8.50 4.12 3.50 -- 8.00 5.12 2.25 --10.10 5.00 -- .19 x .25 8.00 5.12 2.25 --10.10 5.00 -- .19 x .25 6.00 3.88 2.00 --10.10 4.00 -- .16 x .20 6.00 3.88 2.00 --10.10 4.00 -- .16 x .20 Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 THREE-PHASE FILTERS 185A Part Number Maximum Leakage Each L/G (250V, 60Hz) 61 Series F3480/F3600 F3480B & F3600B Dimensions F F3480T & F3600T Dimensions E F G (Slots) E G (Slots) B B NOTE: “N” Lead Not on F3480 NOTE: “N” Terminal Not on F3480 A D A C C LINE LOAD LINE 60A & Above 60A & Above G (Slots) E LOAD G (Slots) E B B NOTE: Only 3 Leads on F3480 (Plus Ground) NOTE: Only 3-Pole Terminal Block on F3480 A D A C C LINE LINE LOAD 50A & Below LOAD 50A & Below THREE-PHASE FILTERS F3600 Series - 600 VAC 62 Rated Current (Amps) 600A 300A 180A 80A Part Number F3600T600 F3600B600 F3600T300 F3600B300 F3600T180 F3600B180 F3600T080 F3600B080 Maximum Leakage Each L/G (250V, 60Hz) 120mA 60mA 60mA 30mA 45A F3600A045 F3600B045 F3600T045 10mA 25A F3600A025 F3600B025 F3600T025 8mA 16A F3600A016 F3600B016 F3600T016 4mA 8A F3600A008 F3600B008 F3600T008 4mA www.curtisind.com Dimensions (Inches) Minimum Insertion Loss (dB) CM DM .15 60 20 .5 60 35 CM DM .15 60 25 .5 60 30 CM DM .15 60 20 .5 60 30 CM DM .15 60 15 .5 60 25 CM DM .15 60 10 .5 60 10 CM DM .15 60 5 .5 60 5 CM DM .15 50 5 .5 70 5 CM DM .15 60 5 .5 70 10 Frequency (MHz) 1 5 50 50 35 30 Frequency (MHz) 1 5 50 50 35 45 Frequency (MHz) 1 5 60 60 35 45 Frequency (MHz) 1 5 60 60 25 40 Frequency (MHz) 1 5 80 70 15 50 Frequency (MHz) 1 5 80 70 30 50 Frequency (MHz) 1 5 80 70 35 40 Frequency (MHz) 1 5 80 70 50 40 10 40 25 30 30 20 10 40 30 30 30 20 10 50 40 30 40 30 10 50 40 30 40 30 10 60 40 30 45 30 10 60 40 30 45 30 10 60 40 30 45 40 10 60 40 30 45 40 A B C D 18.75 5.25 5.93 41.25 18.75 5.25 4.50 -- 10.50 5.25 5.93 26.50 10.50 5.25 4.50 -- 11.25 4.12 4.25 20.25 11.25 4.12 3.50 -- 8.50 4.12 4.25 16.00 8.50 4.12 3.50 -- 8.00 5.12 2.25 8.00 5.12 6.00 6.00 Curtis Industries A Division of Powers Holdings, Inc. E F G 16.00 8.00 .28 x .40 8.00 4.00 .28 x .40 10.00 5.00 .20 x .30 7.00 3.50 .20 x .30 --10.10 5.00 -- .19 x .25 2.25 --10.10 5.00 -- .19 x .25 3.88 2.00 --8.10 4.00 -- .16 x .20 3.88 2.00 --8.10 4.00 -- .16 x .20 Specifications subject to change. Dimensions are shown for reference purposes only. DC FILTERS ] General Purpose High Performance Curtis Industries A Division of Powers Holdings, Inc. 63 DC FILTERS General Purpose FD Series Filters The FD Series of DC filters are designed as a general purpose line of filters for DC applications. They are designed to comply with UL/EN 60950 and UL 1459, CISPER 22 and Telecordia (Bellcore) GR-1089 at 25Amps and above. These filters are available with and without circuit breakers for additional protection. The FD Series is a compact size that can filter up to 300MHz ideally suited for the telecom-datacom market. The FD0 Series is available from 6Amps to 100Amps in the smallest, economical package. The FD02 is a high frequency filter up to 3GHz (3,000MHz) in a compact package. These filters are ideally used in communications and central office equipment. • Power Supplies for Communications Equipment • Network Routing Equipment • Switching Equipment • Base Stations • Modems • Services • Ethernet Hubs Specifications: Rated Voltage: 80VDC Maximum Rated Current: 6A 10A 20A 25A 50A 75A 100A Current Overload: 6X for 8 seconds Hi-Pot Rating (1 min): Line to Ground 1060VDC Line to Line 100VDC Insulation Resistance: 1000 MΩ at 80VDC Ambient Temperature: 0°C to 55°C (32°F to 131°F) Humidity Range: 0% to 95% R.H. Termination: See Chart at Right 6A to 20A (FD0) Wire Leads: 18AWG (FD0 25Amp to 100Amp not available with wire leads) 10AWG 6AWG 4AWG Agency Approvals: 6Amp to 20Amp E78454 30Amp (FD1, FD2, FD3) 50Amp 75Amp & 100Amp 064179 72031306 25Amp to 100Amp E221098 64 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. 72070096 72061592 E221098 Specifications subject to change. Dimensions are shown for reference purposes only. Power Line Filter Selection Guide FD1, FD2, FD3 SERIES 6 FD00BB006 6 FD00AA010 10 FD00BB010 10 FD00AA020 20 FD00DD020 20 FD00DD025 X FD10BB030 30 FD10EE030 30 FD10BB050 50 FD10EE050 50 FD10BB075 75 X X FD10BB100 100 X 25 X FD20B_ _ _ FD00DD050 50 X FD20E_ _ _ FD00DD075 75 X FD20R_ _ _ FD00DD100 100 X FD20D_ _ _ FD02DD025 25 X FD20H_ _ _ FD02DD050 50 X FD20 _B_ _ _ FD02DD075 75 X FD20 _C_ _ _ FD02DD100 100 X FD20 _E_ _ _ X X X X X X X X X X X X X 30, X X 50, or 80 X X X X X FD30B_ _ _ X FD30E_ _ _ X FD30R_ _ _ FD30H_ _ _ FD30 _B_ _ _ X 30, 50, 75, or 100 FD30 _C_ _ _ FD30 _E_ _ _ FD30 _T_ _ _ Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. X X DC FILTERS FD20 _T_ _ _ FD30D_ _ _ Dual Stud T-Block Euro Connector Termination Wire Leads Double Pole Handle Breaker Double Pole Rocker Breaker Part Number Single Pole Rocker Breaker FILTER Current Rating (Amps) Studs Disconnect Type General Purpose FD00AA006 Wire Leads Part Number Quick Connects FILTER Current Rating (Amps) Termination High Current Connector FD00 & FD02 SERIES X X X X X X X 1-800-657-0853 65 FD Series Filters How to Order FD0 0 X Y 000 CURRENT RATING: 006 = 6Amps 010 = 10Amps 020 = 20Amps 025 = 25Amps 030 = 30Amps 050 = 50Amps 075 = 75Amps 080 = 80Amps 100 = 100 Amps SERIES FD0 FD1 FD2 FD3 OPTIONS: 0 = Standard 2 = High Frequency 3-9 = Specials General Purpose LINE TERMINATION: LOAD TERMINATION: A = Quick Connect A = Quick Connect B = Wire Leads B = Wire Leads C = High Current Connector D = Dual Studs/Screw Terminal D = Dual Studs/Screw Terminal E = Euro Block Connector E = Euro Block Connector H = Dual Stud T-Block T = Dual Stud T-Block with DPST Handle Breaker R = Dual Stud T-Block with SPST Rocker Breaker NOTE: Not all terminations are available in all models. DC FILTERS Part Number 66 TYPICAL INSERTION LOSS - dB (50 ohm Circuit) MODE .01 .03 .10 .15 .50 Frequency - MHz 1.0 5.0 10 30 100 300 1000 3000 FD00XX006 FD00XX010 FD00XX020 Common Differential – – – – – – 10 15 22 45 30 60 42 60 47 50 40 50 – – – – – – – – FD00XX025 FD00XX050 FD00XX075 FD00XX100 Common Differential – – – – – – 22 32 50 38 60 50 50 55 45 50 40 40 – – – – – – – – FD02XX025 FD02XX050 FD02XX100 Common Differential 5 40 5 45 35 45 45 45 60 48 60 50 55 45 55 55 50 48 40 45 10 15 20 58 25 40 FD10XX030 FD10XX050 FD10XX075 FD10XX100 Common Differential 5 55 15 60 48 70 60 70 65 70 65 65 60 70 60 60 55 50 25 35 25 15 – – – – FD20XX030 FD20XX050 FD20XX080 Common Differential 5 55 15 65 48 70 60 65 70 60 70 65 70 55 60 50 55 45 – – – – – – – – FD30XX030 FD30XX050 FD30XX075 FD30XX100 Common Differential 12 50 20 60 44 70 60 70 60 70 60 70 60 55 60 70 55 60 – – – – – – – – www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. FD00 Filters FD00AA (6, 10 and 20Amp) Dimensions .188 Dia. (4,77) 2 Holes D L LO A D LI NE L A G N N E F Amps A B C D E F 6A 3.312 (84,1) 2.000 (50,8) 1.125 (28,5) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 10A 3.312 (84,1) 2.000 (50,8) 1.500 (38,2) 2.940 (74,7) 2.500 (63,5) .550 (14,0) 20A L O A D L I N E B F .250 QC (6,4) C See FD00DD below for Case Dimensions A .188 Dia. (4,77) 2 Holes D FD00BB B (6 and 10Amp) Dimensions Amps A B C D E 6A 3.312 (84,1) 2.000 (50,8) 1.125 (28,5) 2.940 (74,7) 2.500 (50,8) 10A 3.312 (84,1) 2.000 (50,8) 1.500 (38,1) 2.940 (74,70) 2.500 (50,8) E C 4.000 (101,6) Min. .250 ±.062 (6,35) Typ. No. 18 Gauge Wire DC FILTERS FD00DD (20Amp) Dimensions .188 Dia. (94,77) 2 Holes 2.500 (63,5) L O A D L I N E General Purpose L O A D L I N E 2.940 (74,7) 3.312 (84,1) (5) No. 8-32 Studs .625 (15,87) 2.000 (50,8) .625 (15,87) 1.500 (38,1) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 67 FD00 & FD02 Filters FD00DD (25, 50, 75 and 100Amp) Dimensions LO A D LI NE 1/4-20 Stud Pair Per Connection -48VDC -48VDC G RTN 2.00 (50,8) RTN .625 (15,875) .69 (17,526) -48VDC .75 -48VDC (19,1) 1.000 (25,4) .25 (6,35) .38 (9,652) RTN 4X 6-32 x .23 RTN .25 (6,35) 1.500 (38,1) 1.25 Max. (31,75) 2.50 (63,5) L O A D L I N E -48VDC 1.50 (38,1) RTN -48VDC LOAD -48VDC G 1/4-20 Stud Pair Per Connection RTN DC FILTERS RTN 3.875 (98,4) .625±.020 (15,875) 1.63 (41,4) www.curtisind.com 1.50 (38,1) -48VDC RTN LINE .38 (9,65) 4X 6-32 x -48VDC RTN RTN 3.000 (76,2) 1.25 Max. (31,75) .38 (9,65) .75 (19,05) .25 (6,35) .44 (11,18) 3.312 (84,12) 1.25 Max. (31,75) -48VDC 1.000 (25,4) 68 .38 (9,65) FD02DD (25, 50 and 100Amp) Dimensions LINE General Purpose 1.25 Max. (31,75) Ø.56 (14,22) LOAD .23 Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. FD1 Filters FD10EE050 -48VDC LO A D LI NE (50Amp) Dimensions -48VDC G RTN RTN A .25 (6,35) D .25 (6,35) .59 (14,99) B + + L O A D L I N E E F – – #6-32 x .23 Min. Deep (4 Places) C Amps A B C D E F 30A, 50A 4.25 (107,95) 3.50 (88,9) 1.37 (34,79) 3.750 (95,25) 3.000 (76.2) 2.33 (59,18) 75A, 100A 4.25 (107,95) 3.50 (88,9) 1.37 (34,79) 3.750 (95,25) 3.000 (76.2) 2.33 (59,18) -48VDC L OAD L INE (100Amp) Dimensions -48VDC G RTN DC FILTERS FD10BB100 .69 (17,53) High Performance Terminals: AWG #8-24 Phoenix P/N VDFK-6 Suitable for Field Wiring RTN .25 .25 (6,35) (6,35) A D .59 (14,99) + B + L I N E L O A D F E – – #4 AWG Wire - 18" LG 105°C TEW-UL 1283 (4 Places) Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. #6-32 x .23 Min. Deep (4 Places) Curtis Industries A Division of Powers Holdings, Inc. C .50 (12,7) 1-800-657-0853 69 FD2 & FD3 Filters FD20HC080 80A LI NE (30, 50 and 80Amp) Dimensions 7.30 (185,4) 1.00 (25,4) .50 (12,7) -48VDC LO A D -48VDC G RTN RTN .50 Max. (12.7) 5.00 Max. (127) LOAD 4.00 (101,6) LINE 8.18 (207,8) .27 (6,858) 3.183 (80,84) 1.45 (36,83) 7.625 (193,7) .28 (7,112) 1.50 (38,1) .060 (1.524) 2.54 (64,5) 2.00 (50,8) .69 (17,5) Line Terminals 1/4-20 x .38 Lg Stud Pairs Terminal Block w/Optional Cover DC FILTERS Circuit Breaker 125% Trip, Medium Delay Red/Black Indicate Off 5000A Fault Current 1.100 (27,94) 4X #6-32 x .250 (6,35) .690 (17,526) www.curtisind.com ON OFF -48VDC G RTN 8.00 (203,2) 2X .260 (6,604) .23 7.52 (191) 4X 12.00±.25 1.17 (29,72) .75 (19,05) -48VDC 7.3 Max. (185,4) 2X .398 L (10,11) I N E 6.740 6.00 (171,2) (152,4) Line Terminals 1/4-20 x .38 Lg Stud Pairs Terminal Block w/Optional Cover 100A RTN RTN -48VDC .250 (6,35) .625 (15,88) 6X Ø .156 -48VDC (30, 50, 75 and 100Amp) Dimensions 1.60 Max. (40,64) LOAD .625 (15,87) 5.500 (139,7) High Current Connector + 48V – FD30RB100 70 2X .44 LINE High Performance 1.21 (30,73) 1.270 (32,26) L O A D 4X .358 (9,903) Curtis Industries A Division of Powers Holdings, Inc. 2.03 (51,56) RTN 1.00 Wire (25,4) #4AWG TEW-4 UL1283 -48VDC - Red RTN - Black 2 Wires per Terminal 4X .260 (6,604) 1.60 Max. (40,64) Specifications subject to change. Dimensions are shown for reference purposes only. MEDICAL FILTERS ] General Purpose Combination Curtis Industries A Division of Powers Holdings, Inc. 71 F3099 RFI Filters Maximum Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 250VAC 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1450VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: Quick Connect B: Wire Maximum Leakage Current: Each Line to Ground F3099 Series 115VAC, 60Hz: 2 µA 250VAC, 50Hz: 5 µA Agency Approvals: Features: • Designed to Meet UL544 and IEC601 Specifications for Medical and Dental Equipment, both patient care and onpatient categories. • Leakage current in this series is extremely low to satisfy the stringest leakage current limit imposed by safety regulations for medical and dental equipment. E78454 F3099AA (6Amp) Dimensions 6A A B C D E 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 2.53 (64,30) 2.53 (64,30) 1.82 (46,2) 0.78 (19,8) 2.126 (54,0) 1.32 (33,5) MEDICAL FILTERS Nominal Current Rating 6A 72 Part Number BLUE A D F3099AA06 F3099BB06 www.curtisind.com BLUE G/Y BROWN BROWN QC/QC Wire/Wire B E C Termination Line/Load N WIRE LEADS, 18AWG, (16AWG FOR 10A). 102(4.0) MIN. B E G N 6.36(0.25) FASTON TERMINAL WITH Ø1.78 (0.070) HOLE (SLOTTED HOLE FOR GROUND) A D L L LOAD Amps 099523 72102892 F3099 Series Simplified Schematic LINE General Purpose Filtered Modules Specifications: C MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Common Differential 0.05 0.10 .15 3 — 7 3 11 6 Curtis Industries A Division of Powers Holdings, Inc. Frequency - MHz .50 1.0 20 14 22 20 5.0 10 30 24 35 22 35 18 35 Specifications subject to change. Dimensions are shown for reference purposes only. F3000/3100/3200/3400/3500 RFI Filters Specifications: Features: E78454 • Designed to Meet UL544 Specification for Medical and Dental Equipment. Available to UL/IEC 60601 Standard • F3400/F3500 Have Enhanced Differential Mode Performance • Effective in Other Low-Leakage Current Applications F3000/F3100/F3200 Series Simplified Schematic N 6A Part Number Termination Line/Load L LOAD L IN E LOAD G Nominal Current Rating L L N 3A F3400/F3500 Series Simplified Schematic G N N MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 .50 Frequency - MHz 1.0 5.0 10 30 F3400CA03 F3500CA03 IEC/QC IEC/QC Common Differential 22 8 32 18 35 24 30 35 25 35 20 35 F3000AA06 F3100CA06 F3200CA06 QC/QC IEC/QC IEC/QC Common Differential 10 20 2 23 8 25 32 23 34 15 23 F3400CA06 F3500CA06 IEC/QC IEC/QC Common Differential 15 8 21 18 24 24 24 35 22 35 26 35 MEDICAL FILTERS L IN E L 064179 72031206 72031376 General Purpose Filtered Modules Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect C: IEC Receptacle Maximum Leakage Current: Each Line to Ground F3000 Series 115VAC, 60Hz: 2 µA 250VAC, 50Hz: 5 µA Agency Approvals: NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 73 F3000/3100/3200/3400/3500 (continued) F3000AA .188 Dia. (4,77) 2 Holes (6Amp) Dimensions L I N E 1.750 (44,5) General Purpose Filtered Modules .550 (14) L O A D 2.125 2.50 (53,9) (63,5) .875 (22,2) .550 (14) .625 (15,8) .250 QC (6,4) F3100CA .881 (22,4) (6Amp) F3400CA (3 and 6Amp) Dimensions 1.575 1.980 (40.0) (50,29) Max. Refer to Page 58 for Standard Mounting Cutouts L I N E L O A D 1.145 (29,08) 1.415 (35,94) .113 Dia. (3,30) 2 Holes .550 (14) MEDICAL FILTERS .805 (22,4) F3200CA (6Amp) .250 QC (6,4) .881 (22,4) F3500CA (3 and 6Amp) Dimensions 1.980 (50,29) 1.575 Max. (40,0) L O 1.145 A (29,08) D L I N E 1.555 (39,5) .133 Dia. (3,38) 2 Holes .550 (13,97) . 250 QC (6,4) .805 (22,4) 74 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. F3300 RFI Filters Specifications: • General Purpose “L-Type” Circuit Effective in Reducing Both Incoming and Outgoing Powerline Noise Levels in FCC “A” Applications • Integral 5 X 20mm Single or Dual Fused IEC Connector • Optional SST Switched IEC Connector • Low-Leakage • Available to UL/IEC 60601 Standard and Meets UL 544 Specification for Medical and Dental Applications • Available in Labor-Saving PC Mounted Case Style E78454 064179 72031310 F3300F Simplified Schematic L LOAD LINE L G N Part Number 3A F3300FA03 F3300FP03 Fused IEC/QC Fused IEC/PC 6A F3300FA06 F3300FP06 3A Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE Frequency - MHz 1.0 5.0 .15 .50 10 30 Common Differential 21 8 32 18 36 24 30 35 28 35 28 35 Fused IEC/QC Fused IEC/PC Common Differential 18 8 30 18 34 24 26 35 25 35 25 35 F3300WA03 F3300WP03 Dual Fused IEC/QC Dual Fused IEC/PC Common Differential 21 8 32 18 36 24 30 35 28 35 28 35 6A F3300WA06 F3300WP06 Dual Fused IEC/QC Dual Fused IEC/PC Common Differential 18 8 30 18 34 24 26 35 25 35 25 35 3A F3300JA03 F3300JP03 Switched IEC/QC Switched IEC/PC Common Differential 21 8 32 18 36 24 30 35 28 35 28 35 6A F3300JA06 F3300JP06 Switched IEC/QC Switched IEC/PC Common Differential 18 8 30 18 34 24 26 35 25 35 25 35 MEDICAL FILTERS Nominal Current Rating N General Purpose Filtered Modules Features: Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 6A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at Rated Current Humidity Range: 0% to 95% R.H. Termination: A: QC – Quick Connect F: Fused IEC J: Switched IEC P: PCB Pins W: Dual Fused IEC Maximum Leakage Current: Each Line to Ground F3300 115VAC, 60Hz: .015mA 250VAC, 50Hz: .025mA Agency Approvals: NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 75 F3300 Series (continued) F3300FA (3 and 6Amp) Dimensions L I N E .20 (5,0) F3300FP (3 and 6Amp) Dimensions L O A D 1.140 (28,9) 2.000 (50,8) 1.730 (43,9) Refer to Page 58 for Standard Mounting Cutouts .550 (13,9) L I N E .20 (5,0) 1.260 (32,0) 1.296 (32,9) .200 REF (5,0) 2.20 (55,9) 1.730 (43,9) 2.75 (69,8) 1.140 (28,9) 1.260 (32,0) 1.296 (32,9) 1.420 (36,0) (1) 5mm x 20mm Fuse (not included) 1.420 (36,0) .210 (5,3) F3300WA (3 and 6Amp) Dimensions L I N E F3300W Simplified Schematic L LOAD L LINE General Purpose Filtered Modules LOAD G N .550 (13,9) 1.260 (32,0) 1.339 (34,0) (2) 5mm x 20mm Fuses (not included) F3300JA (3 and 6Amp) Dimensions L I N E F3300J Simplified Schematic L L OAD LINE L G N .17 (5,0) N L O A D 2.000 (50,8) 1.420 (36,0) www.curtisind.com 1.140 (28,9) .550 (13,9) 2.72 (69,8) 1.736 (44,0) 1.339 (34,0) 76 1.140 (28,9) 2.75 (69,8) 1.736 (44,0) 1.420 (36,0) MEDICAL FILTERS 2.000 (50,8) 1.8 (5,0) Max. N L O A D Curtis Industries A Division of Powers Holdings, Inc. 1.260 (32,0) SPST Switch Specifications subject to change. Dimensions are shown for reference purposes only. FPM7/FPM8 Series Specifications: Features: E78454 • RFI Filter Module Combines IEC Connector, Fusing, and Voltage Select Features in One Unit • FPM7 Series Filters Provide 20% More Differential Mode Attenuation Than Comparable Units • Accepts Either U.S. or European Standard Fuse Sizes • Available to UL/IEC 60601 Standard and Meets UL 544 Specification for Medical and Dental Applications 064179 72031305 Refer to Page 80 for Ordering Instructions General Purpose Filtered Modules Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 3A 3A 6A 6A Current Overload: 6X for 8 Seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 1768VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max. at Rated Current Humidity Range: 0% to 95% R.H. Termination: • IEC Receptacle • Wire Wrap/Solder Maximum Leakage Current: Each Line to Ground FPM7, FPM8 115VAC, 60Hz: 0.002mA 250VAC, 50Hz: 0.005mA Voltage Select Card: Installed in 120VAC position unless otherwise specified Agency Approvals: FPM7 Series Simplified Schematic FUSING LINE G B A a b G FOR TRANSFORMERS WITH TAP LOAD C A C 240V 220V MEDICAL FILTERS L SERIES-SERIES 110-220240 V VOLTAGE SELECTOR 1-POLE c D D N Voltage Contacts 110V b,e 220V b,c 240V a d H F E e 2-POLE E F 2a 110V G Nominal Current Rating Part Number LINE L Termination Line/Load MINIMUM INSERTION LOSS - dB (50 ohm Circuit) FUSING MODE 1-POLE G 100-120220-240 V VOLTAGE SELECTOR B 3A FPM7XXX03 FPM8XXX03 G IEC/Solder Tabs Common Differential 6A FPM7XXX06 N FPM8XXX06 IEC/Solder Tabs Common H Differential F LOAD .50 .15 a b c A 14 8 C 10 8 E A C20 SERIES-PARALLEL Frequency - MHz FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 1.0 5.0 10 120V 100V 18 D D d e 2-POLE 15 E18 120V F G Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. LINE L 22 24 18 24 24 46 Voltage Contacts 100V 18 a,c,e 120V 39 b,c,e 220V a,d 240V b,d Curtis Industries A Division of Powers Holdings, Inc. FUSING G LOAD 115-230 V VOLTAGE SELECTOR 1-POLE B a A B A 22 50 15 40 18 40 15 40 1-800-657-0853 SERIES-PARALLEL FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 115V 30 77 L D B H NG F 2-POLE c e E C d E FPM7/FPM8 Series (continued) e F 2-POLE FPM7 Series Simplified Schematic FUSING LINE G L FUSING LINE G B 1-POLE G L D B NG F 2-POLE a 100-120220-240 V b VOLTAGE SELECTOR c c FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS A E SERIES-PARALLEL 120V FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 100V LOAD C 120V DA C E F D C 100V 120V d 120V E e F GE F 2-POLE G FUSING LINE G L FUSING LINE G B a 115-230 V VOLTAGE b SELECTOR 1-POLE G L D B F 2-POLE A e c E C D F e Combination FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS 115V 115V 115V E GE F 2-POLE Voltage Contacts 115V a,b d,e 230V c Voltage Contacts 115V a,b d,e 230V c G FPM8 Series Simplified Schematic LINE SERIES-PARALLEL 115V d H N c d b H NG C a FOR TRANSFORMERS WITH TWO SEPARATE WINDINGS B A LOAD C B DA C E F D A Voltage Contacts 100V a,c,e 120V b,c,e Voltage a,d Contacts 220V 100V 240V b,da,c,e 120V b,c,e 220V a,d 240V b,d SERIES-PARALLEL LOAD 115-230 V VOLTAGE SELECTOR 1-POLE Voltage Contacts 110V b,e 220V b,c Voltage Contacts 240V a 110V b,e 220V b,c 240V a G A C D H N A a e 110V LOAD d b H 220V 110V SERIES-PARALLEL 100-120220-240 V VOLTAGE SELECTOR 1-POLE 240V DA C E F D 2a E GF 2a D H N A a d b ROCKER SWITCH FUSING 1-POLE G L 1-POLE 1 1a LOAD L MEDICAL FILTERS G 78 H N 2-POLE 2 2a N 2-POLE G www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. FPM7/FPM8 Snap-Mount Series (3 and 6Amp) Dimensions Refer to Page 80 for Standard Mounting Cutouts 2.266 (57,55) 1.260 (32,0) 1.051 (26,70) .22 (5,5) 2.283 (58,0) .100 (2,7) Q.C. Terminals All Locations LI N E L OAD 1.091 (27,71) 1.051 (26,70) Combination 1.091 (27,71) MEDICAL FILTERS FPM7/FPM8 Screw-Mount Series 1-800-657-0853 79 (3 and 6Amp) Dimensions 1.969 (50,0) Refer to Page 80 for Standard Mounting Cutouts 2.266 (57,55) 1.575 (40,0) .22 (5,5) 1.142 (29,0) 2.283 (58,0) LINE Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. .126 (3,20) Dia. Holes .100 (2,7) Terminals Except Switch Curtis Industries A Division of Powers Holdings, Inc. LOAD FPM7/FPM8 Series (continued) How to Order FPM7 FPM8 X X X X X SERIES FPM= Medical Power Entry CURRENT RATING 3 = 3 AMP 6 = 6 AMP OPTIONS (Consult Factory) 0 = Standard Units SWITCH 0 = No Switch 1 = SPST Rocker Switch w/Q.C. 2 = DPST Rocker Switch w/Q.C. VOLTAGE SELECTOR 0 = No Selector (FPM80 Series) 1 = 110-220-240 VAC 2 = 100-120-220-240 VAC 3 = 115-230 VAC MEDICAL FILTERS Combination MOUNTING METHOD & FUSING 0 = Snap Mount Metric Fuse 1 = Snap Mount US Fuse 2 = Snap Mount 2 Metric Fuses 3 = Snap Mount 2 US Fuses 6 = Screw Mount Metric Fuse 7 = Screw Mount U.S. Fuse 8 = Screw Mount 2 Metric Fuses 9 = Screw Mount 2 U.S. Fuses FPM7/FPM8 Snap-Mount Series 2.20 (55,9) *See Below *Panel Thickness www.curtisind.com 1.10 (27,9) 2.20 (55,9) 1.575 (40,0) 1.122 (28,50) Cutout .031" - .079" use 2.20" .080" - .125" use 2.22" 80 FPM7/FPM8 To change fuse, remove power cord and open the front cover on the module. Remove fuse holder and replace fuse. Reinsert fuse holder and close cover. To change the operating voltage on the FPM7 Series, remove the power cord and open front cover. Rotate voltage select wheel until desired voltage appears in window of cover. • Filter shipped without fuse. Always use caution when selecting and changing fuses and voltage requirements. Curtis Industries is not responsible for malfunction due to improper installation/selection of fuse and/or voltage select. FPM7/FPM8 Screw Mount Series .08 R (2,0) 1.122 (28,50) INSTALLATION INSTRUCTION IMPORTANT – CHANGING FUSE/VOLTAGE .08 R (2,0) 4-40 (M3) Curtis Industries A Division of Powers Holdings, Inc. Specifications subject to change. Dimensions are shown for reference purposes only. FPM1 Series Specifications: FPM1 Series Simplified Schematic without Voltage Selector 2 3 4 2 POLE G G 064179 72031202 FUSING 1 POLE 1 LINE 2 L LOAD E78454 L 1 3 4 N N 2 POLE G G Combination • RFI Filter Module Combines IEC Connector, Fusing, Optional Voltage Select and On/Off Switch into a Single, Space-Efficient Assembly • Enhanced Low Frequency Response with No Resonant Peaks • Fully Shielded for Radiative Noise Control • Accepts Either U.S. or European Standard Fuse Sizes. Dual or Single Power Line Fusing • Meets IEC 60601 Standard and Meets UL 544 Specification for Medical and Dental Applications LINE Features: Rated Voltage: 250VAC Maximum - 50/60 Hz Rated Current: 115VAC 250VAC 10A 10A Current Overload: 6X for 8 seconds Hi-Pot Test (1 min): Line to Ground 1500VAC Line to Line 2250VDC Insulation Resistance: 9 x 109 Ω at 100VDC Ambient Temperature: 40°C Max at rated current Humidity Range: 0% to 95% R.H. Termination: • QC – Quick Connect • IEC Receptacle Maximum Leakage Current: FUSING Each Line to Ground PM1 PM1-PO 1 POLE L 0.002mA 0.015mA L 115VAC, 60Hz: 250VAC, 50Hz: 0.005mA 0.025mA Voltage Select Card: Installed in 120VAC position unless otherwise specified N N Agency Approvals: FPM1 Series Simplified Schematic with Voltage Selector FUSING 1 POLE L 1 N FPM1XXXP0 2 POLE G MINIMUM INSERTION LOSS - dB (50 ohm Circuit) MODE .15 1 IEC/QC Common Differential 10 10 202 IEC/QC Common Differential 12 10 4 23 20 NOTE: Other combinations of terminals may be specified on special order. Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. .05 L LOAD FPM1XXX10 L IN E 10A 1 POLE LOAD LIN E Part Termination Number FUSING Line/Load 110V 4 2 POLE G G L 3 N N Nominal Current Rating 110V 2 MEDICAL FILTERS L 20 3 N Frequency - MHz .50 1.0 5.0 10 30 30 30 33 35 25 55 20 60 15 55 30 30 35 35 25 65 25 65 30 55 G Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 81 1 1 FPM1 Series (continued) FPM1 1.99 (50,5) (10Amp) Dimensions L I N E L O A D 2.41 (61,2) Max. 1.12 (28,4) 3.00 (76,2) 2.58 (65,5) Max. 1 2 H 1.575 (40,01) 1.15 (29,2) Max. 3.20 (81,3) WITH VOLTAGE SELECTOR How to Order FPM1 X X X X MEDICAL FILTERS Combination SERIES FPM= Medical Power Entry X CURRENT RATING 0 = 10 AMP MOUNTING METHOD & FUSING 6 = Screw Mount Metric or U.S. Fuse* 8 = Screw Mount 2 Metric or U.S. Fuses * U.S. Fuse not available without voltage selector FPE1 Screw Mount Series OPTIONS (Consult Factory) 1 = Standard Units P = High Performance Insertion Loss SWITCH 0 = No Switch 1 = SPST Rocker Switch 2 = DPST Rocker Switch VOLTAGE SELECTOR 0 = No Selector 3 = 115-230 VAC 1.20 (30,6) R.03 Max. INSTALLATION INSTRUCTION IMPORTANT – CHANGING FUSE/VOLTAGE +.02 2.41 –0 (61,2) M3 +.02 1.15 –0 (29,2) 1.575 ±.005 (40,0) 82 www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. FPM1 To change fuse, remove power cord. Remove voltage selector and replace fuse. Reinsert fuse holder. To change the operating voltage on the FPM1 Series, remove the power cord and rotate fuse holder block until desired voltage aligns with the mark on the module housing. • Filter shipped without fuse. Always use caution when selecting and changing fuses and voltage requirements. Curtis Industries is not responsible for malfunction due to improper installation/selection of fuse and/or voltage select. Specifications subject to change. Dimensions are shown for reference purposes only. TECHNICAL CONSIDERATIONS ] Understanding Terminology Technical Considerations Conducted Emissions Testing Custom Filter Capabilities Curtis Industries A Division of Powers Holdings, Inc. 83 Understanding Terminology Curtis Industries, a leading manufacturer of superiorquality electronic and electrical components and assemblies for more than 70 years, offers a complete line of RFI power line filters designed to help your equipment meet FCC and CE requirements on conducted EMI. Radio frequency interference (RFI) is unwanted noise generated by a wide variety of electronic and electrical devices. Governments of most industrial countries, including the United States, Canada and the European Union have enacted guidelines on emitted RFI. Curtis designs quality into every product and then tests for quality by specification compliance, including hipot, component value, grounding and leakage, on a 100% production basis. We employ a rigorous component qualification program with thorough incoming and on-line inspection procedures. Our computercontrolled 100% safety and performance testing to demanding customer requirements is your assurance of the highest quality RFI filters available today. This section provides you with some basic knowledge on terminology and technical information helpful in solving your noise emission in power circuits. For additional information visit our website at www.curtisind.com. Definitions Attenuation: The decrease in intensity or absorption of electromagnetic energy. Expressed in dB. Conducted Interference: Electromagnetic signals entering a device through direct connection. Emissions: The level of electromagnetic disturbances equipment causes to its environment. Filter: Remove electrical noise or interference from the power line by cleaning up the sine wave. Immunity: The level to which equipment is immune to electromagnetic disturbances in its environment TECHNICAL CONSIDERATIONS Impedance: Opposition to the flow of 84 electrical current when a given voltage is applied. Inductor: Passive component that produces a voltage proportional to the change in current. Measured in Henrys. Insertion Loss: The electromagnetic signal loss resulting from the insertion of a filter in a transmission line. Expressed in dB. www.curtisind.com Curtis Industries A Division of Powers Holdings, Inc. What is RFI? Radio frequency interference (RFI) is the radiation or conduction of radio frequency energy (or electronic noise) produced by electrical and electronic devices at levels that interfere with the operation of adjacent equipment. Frequency ranges of most concern are 10 kHz to 30 MHz (conducted) and 30 MHz to 1 GHz (radiated). What causes RFI? The most common sources include components such as switching power supplies, relays, motors and triacs. These devices are found in a wide variety of equipment used in industrial, medical, white goods, and building HVAC equipment. What are the types of RFI? An electrical or electronic device emits RFI in two ways: l Radiated RFI is emitted directly into the environment from the equipment itself. l Conducted RFI is released from components and equipment through the power line cord into the AC power line network. This conducted RFI can affect the performance of other devices on the same network. How can RFI be controlled? Radiated RFI is usually controlled by providing proper shielding in the enclosure of the equipment. l Conducted RFI can be attenuated to satisfactory levels by including a power line filter in the system. The filter suppresses conducted noise leaving the unit, reducing RFI to acceptable levels. It also helps to lower the susceptibility of the equipment to incoming power line noise that can affect its performance. l How do RFI power line filters work? Consisting of a multiple-port network of passive components arranged as a dual low-pass filter, the RFI filter attenuates radio frequency energy to acceptable levels, while permitting the power frequency current to pass through with little or no attenuation. Their function, essentially, is to trap noise and to prevent it from entering or leaving your equipment. RFI is conducted through a power line in two modes. Asymmetric or common mode noise occurs between the line and ground. Symmetric or differential mode is measured from line to line. See the selection guide on page 2 under “Performance.” Governments and safety agencies of major industrial countries, including the United States, Canada, and the European Union have established noise emission regulations that are focused on digital and other electronic equipment. The most important of these guidelines are FCC CFR 47 (Parts 15 and 18) in the United States and CISPR 11, 14 and 22 in the European Union. FCC CFR 47 (Part 15) regulates the RF Dimensions are in inches and millimeters unless otherwise specified. Values in parentheses are metric equivalents. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 TECHNICAL CONSIDERATIONS What is the government’s role in regulating RFI? interference of electronic computing devices, defined as any electronic device or system that generates and uses timing signals or pulses at a rate in excess of 10,000 pulses (cycles) per second and uses digital techniques. This definition includes telephone equipment that utilizes digital techniques and any device or system that generates and uses radio frequency energy for the purpose of performing dataprocessing functions such as electronic computations, operations, transformations, recording, filing, sorting, storage, retrieval or transfer. FCC regulations are broken down into Class A computing devices marketed for use in commercial, industrial or business environments, and Class B devices intended for use in a residential environment. The European Union has harmonized the various national regulations and has established the international standards CISPR 11, 14 and 22. CISPR 11 covers industrial, scientific and medical equipment. CISPR 14 covers electrical and thermal appliances and tools. CISPR 22 covers information technology equipment. In addition to governmental regulations, safety agencies worldwide have established guidelines for all electrical/electronic components. These include UL, CSA and TUV. They are designed to protect against shock and fire hazard. 85 Technical Considerations Meeting Emissions Standards The emissions limits that a piece of equipment must meet will depend on the intended market for that piece of equipment. If there is more than one market, more than one emission standard may have to be met. This can have a substantial effect on the circuit, size, and cost of a filter. Standards like the CISPR’s or the FCC Rules Part 15 have frequency limits of 150 kHz to 30 MHz. FCC 15 AND CISPR CONDUCTED EMISSION LIMITS DIGITAL EQUIPMENT 80 – Quasi-peak Noise Modes 78 – 76 – 70 – Power line filters attenuate noise in two different modes. Common Mode: Also known as line-to-ground noise measured between the power line and ground potential. Differential Mode: Also known as line-to-line noise measured between the lines of power. Power line filters are designed to attenuate either one or both modes of noise. The need for one design over another will depend on the magnitude of each noise type present. The attenuation is measured in dB (decibels) at various frequencies of signal. Class A Industrial 74 – 72 – Average 68 – 66 – dBµV Class A Industrial 64 – 62 – Quasi-peak 60 – Class B Residential 58 – 56 – 54 – 52 – Average 50 – Circuit Configuration Class B Residential 48 – 46 – 0,15 0,5 5 30 TECHNICAL CONSIDERATIONS Frequency (MHz) 86 (Line Impedance Stabilization Network) and using signal generators to inject RF of varying amplitude and frequency, some insight can be gained as to the nature of the problem. However, the criteria for acceptable performance will have to be decided upon so that a filter yielding this level of performance can be obtained from the test procedure. Unfortunately, this still does not eliminate the need for final testing in the actual operating environment which, in many cases, occurs in the field. Selection of a suitable filter can best be based on the type of power supply or input impedance of the equipment and on the mode of the offending RFI noise. EMI measurements are generally made using Spectrum Analyzers with Average or Quasi-Peak detectors in accordance with methods described in CISPR 16. Quasi-Peak differs from Average measurements by weight-averaging the peaks into the total. Equipment meeting these specifications can utilize a filter with a fairly high cutoff frequency. Other standards like FCC 18 with a low frequency limit of 10 kHz will result in the equipment using lower cutoff filters. As might be expected, the lower the cutoff frequency, the larger the physical size and the higher the cost of the filter. Conducted RFI Susceptibility The problem of susceptibility can be extremely difficult to deal with because the amplitude and frequency of the offending RF noise are seldom known and are often intermittent. If the malfunction can be duplicated by isolating the equipment from the power line with LISN’s www.curtisind.com Power line RFI filters are generally built with two or three-pole filter networks. As the number of poles and the corresponding component count increases, the cost will increase also. Trying to typify an equipment’s impedance as either high or low for purposes of filter selection may not be successful. If it is a complex impedance, it could probably be low at some frequencies, high at others, and some intermediate value at still other frequencies. Although we have been generally successful in recommending a two-pole network for linear power supplies and three-pole networks for switching power supplies and synchronous motors, you should not limit your testing to just one circuit type if either additional circuit performance or lower cost is desired. Consider the following: If the equipment looked strictly capacitive, the performance of a two-pole network would be reduced to that of a single-pole filter. Figure 1a. A signal source (E) with its internal impedance driving a capacitive load. Curtis Industries A Division of Powers Holdings, Inc. Undoubtedly the two-pole filter would be a more economical choice with probably equal performance in this application. Since the equipment is not likely to be equivalent to either one of these simple cases, the only way to find the best cost-effective solution is to test the filters in your equipment and base your judgement on these test results. Figure 1b. The same circuit as in Figure 1a, with the addition of a 2-pole low pass filter. Notice filter capacitor C1 is in parallel with the capacitive load. Figure 1c. Combining capacitor C1 in Figure 1b, with the load results in this circuit configuration. The filter has been reduced to one inductive element, L1. Obviously a three-pole filter would be preferred for maximum performance. Likewise, if the equipment looked strictly inductive, the performance of a threepole network would be reduced to that of a two-pole network. Figure 2a. A signal source with its internal impedance driving an inductive load. Figure 2b. Figure 2c. Combining inductor L2 in Figure 2b, with the load results in this circuit configuration, the filter has been reduced to two effective elements, L1 & C1. The maximum leakage current that a device is allowed depends on the requirements of the particular safety agency involved. Here, selection of the filter is quite easy since either the filter is designed to meet a given level or it is not. Although there is no compromise when it comes to safety specifications, it should be understood that for a given level of performance, as the leakage current is reduced, the physical size of the package will increase. Curtis medical filters have a very low leakage current. Insertion Loss DO NOT use the insertion loss specifications to make your final decision. Power line filters are two-terminal pair passive networks whose attenuation characteristics can be defined by a complex transfer function. How that transfer function will react in a particular system and at specific frequencies will depend on the complex impedances connected to each side of the filter. The equipment impedance and the impedance of the power line, even if a 50 ohm LISN (Line Impedance Stabilization Network) is being used during emission testing, will not generally be equal to the resistive 50 ohms used during insertion loss measurements. Therefore, the performance of the filter in the equipment cannot be related to the published insertion loss data. Minimum Insertion Loss Do not be alarmed that the insertion loss figures we have published may be of lower value than those of our competition. You will only find guaranteed minimum insertion loss figures in this catalog, without any mention of typical values. Insertion loss test data measured in a 50 ohm system is a valuable incoming inspection tool to assure you that consistent product is being shipped. The only figures of any importance are those that specify the criteria for acceptance or rejection of that product, and those figures are the minimum values. Curtis Industries A Division of Powers Holdings, Inc. 1-800-657-0853 TECHNICAL CONSIDERATIONS The same circuit as in Figure 2a, with the addition of a 3-pole low pass filter. Notice filter inductance L2 is in series with the inductive load. Leakage Current 87 RFI/EMI Conducted Emissions Testing Curtis offers full RFI/EMI conducted emissions testing services for manufacturers who must produce equipment in accordance with FCC and CE standards. Curtis testing facilities consist of a laboratory equipped to test and evaluate EMI characteristics of equipment that must comply with FCC Part 15 and/ or CISPR standards. With these facilities, Curtis can provide manufacturers with greater assistance in the selection of RFI/EMI filters to help them meet the necessary emission levels. Isolated Environment Enhances Test Capabilities l l l l l l Totally isolated environment for both equipment under test and test instrumentation provided by separate chambers. RF screen room shielded against magnetic, electric and plane wave field per MIL-STD-285. Specially constructed line impedance stabilization networks (LISN) for FC Part 15 and CISPR testing. Sensitive, reliable automatic measurement and recording of conducted emissions data from 10 KHz to 1 GHz. Computer-controlled Agilent E7402A Spectrum Analyzer with associated amplifiers and attenuators. Agilent E7402A graphics capabilities allow quick generation of hard copies of emissions test results. The Curtis screen room provides complete RFI isolation for equipment under test and the test instrumentation. TECHNICAL CONSIDERATIONS Computer-controlled test equipment assures fast turnaround on RFI emissions testing. 88 Fast Pre-Compliance Test Results Computer-generated graphics and test reports provide the customer with fast turnaround on all testing. On-site RFI filter design/applications engineers are available to assist in evaluating test results and to determine cost-effective solutions to conducted emissions problems before going to agencies. Please contact your local Curtis representative or the factory sales staff to coordinate pre-compliance testing of your equipment at Curtis Industries. www.curtisind.com Curtis can provide environmental testing to demonstrate performance and survival in harsh conditions. Curtis Industries A Division of Powers Holdings, Inc. RFI RFI Power Power Line Line Filters Filters Terminal Blocks Family FamilyofofProducts Products > RFI RFI FIlters FIlters >> > Filtered Filtered Power Power Entry Entry >> > Custom Custom Filters Filters >> > Terminal Terminal Blocks Blocks >> > Custom Custom Terminal Terminal Blocks Blocks >> > Liquid Liquid Level Level Controllers Controllers >> > PCB PCB Mount Mount Blocks Blocks >> > DIN DIN Rail Rail RFI POWER LINE FILTERS >> R5 4.12 2400 2400 S. 43rd. S. 43rd. St. St. Milwaukee, Milwaukee, WI WI 53219 53219 1-800-657-0853 1-800-657-0853 www.curtisind.com www.curtisind.com Innovative Innovative Innovative Engineering Engineering Engineering Solutions Solutions Solutions
F1770AA06 价格&库存

很抱歉,暂时无法提供与“F1770AA06”相匹配的价格&库存,您可以联系我们找货

免费人工找货