0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
FGLG.14RD

FGLG.14RD

  • 厂商:

    TECHFLEX

  • 封装:

    -

  • 描述:

    INSULTHERM TRUFIT 14AWG 500' RED

  • 数据手册
  • 价格&库存
FGLG.14RD 数据手册
EXTREME TEMPERATURE Technical Data Sheet ADVANCED ENGINEERING Technical Data Sheet Put-Ups UL Recognized: VW-1 Nominal Size Diameter Part # Wall Thickness ±0.005” Expansion Range Min. Max. Bulk Spool Shop Spool Available Colors 24 0.022” FGLG.24 0.005” 0.020” 0.027” 500’ 250’ 6 F  or High Temp - Low Voltage Applications 22 0.027” FGLG.22 0.005” 0.025” 0.032” 500’ 250’ 6 20 0.034” FGLG.20 0.009” 0.032” 0.039” 500’ 250’ 6 18 0.042” FGLG.18 0.011” 0.040” 0.049” 500’ 250’ 6 E  asy To Install-Cuts With Scissors 16 0.053” FGLG.16 0.011” 0.051” 0.061” 500’ 250’ 6 14 0.066” FGLG.14 0.011” 0.064” 0.072” 500’ 250’ 6 12 0.085” FGLG.12 0.011” 0.081” 0.089” 250’ 100’ 6 R  esists Most Organic Solvents 11 0.095” FGLG.11 0.011” 0.091” 0.101” 250’ 100’ 6 10 0.106” FGLG.10 0.011” 0.102” 0.112” 250’ 100’ 6 9 0.118” FGLG.09 0.011” 0.114” 0.124” 250’ 100’ 6 8 0.133” FGLG.08 0.011” 0.129” 0.141” 250’ 100’ 6 7 0.148” FGLG.07 0.013” 0.144” 0.158” 250’ 100’ 6 6 0.166” FGLG.06 0.013” 0.162” 0.178” 250’ 100’ 6 5 0.186” FGLG.05 0.013” 0.182” 0.198” 250’ 100’ 6 4 0.208” FGLG.04 0.016” 0.204” 0.224” 250’ 100’ 6 3 0.234” FGLG.03 0.016” 0.229” 0.249” 250’ 100’ 6 2 0.263” FGLG.02 0.016” 0.258” 0.278” 250’ 100’ 6 1 0.294” FGLG.01 0.016” 0.289” 0.311” 100’ 50’ 6 0 0.330” FGLG.00 0.016” 0.325” 0.347” 100’ 50’ 6 3/8” 0.375” FGL0.38 0.016” 0.375” 0.399” 100’ 50’ 6 7/16” 0.438” FGL0.44 0.018” 0.438” 0.462” 100’ 50’ 6 1/2” 0.500” FGL0.50 0.018” 0.500” 0.524” 100’ 50’ 6 5/8” 0.625” FGL0.63 0.018” 0.625” 0.655” 100’ 50’ 6 3/4” 0.750” FGL0.75 0.018” 0.750” 0.786” 100’ 50’ 6 1” 1.000” FGL1.00 0.018” 1.000” 1.040” 100’ 50’ 6 Cut And Abrasion Resistant Heat Treated, Fray-Resistant Fiberglass Sleeving Cut Cleanly Scissors Material Acrylic Coated Fiberglass Grade FGL Wall Thickness Refer to Chart Drawing Number TF001INS-WD Techflex® INSULTHERM® TRU-FIT (FGL) is a braided fiberglass sleeving which has been heat treated and impregnated with an acrylic binder to reduce fraying and dusting, and improve usability and performance. FGL is engineered for applications where temperatures as high as 1,200ºF may be encountered. FGL is used as primary insulation on low voltage applications such as leads in toasters, coffee makers, ranges and other appliances. FGL may also be used as insulation and protection for small heaters and resistors that operate at high temperatures, and to insulate over soldered connections when exposure to solder melt temperatures is possible. Colors Available: 6 = WH, NT, YL RD, BL, BK Insultherm® Tru-Fit provides a sturdy, long lasting and inexpensive insulation solution. It is flexible and expandable, and can easily be installed over applications with irregular shapes and tight turns. Standard color are Black and Natural, but other colors are available by special order. Contact your Account representative for details. Colors Available: www.techflex.com VW-1 1 (833) SLEEVING • (973) 300-9242 • fax: (973) 300-9409 104 Demarest Road • Sparta, NJ 07871 White (WH), Natural (NT), Yellow (YL), Red (RD), Blue (BL), Black (BK). EXTREME ADVANCED ENGINEERING TEMPERATURE Technical Data Sheet Technical Data Sheet Melt Point ASTM D-2117 ABRASION Very High Rating_____________________ UL VW-1 Maximum Continuous Mil-I-23053 1,202°F (650°C) Abrasion Test Machine Taber 5150 Abrasion Test Wheel Calibrase H-18 Abrasion Test Load 500g Room Temperature 75°F Humidity 15% Slight Fraying 200 Test Cycles Slight Fraying 1,000 Test Cycles Fraying 1,700 Test Cycles Material Destroyed 2,300 Test Cycles Pre-Test Weight 15.3 g Post-Test Weight 13.6 g Test End Loss Of Mass Point Of Destruction 11% CHEMICAL RESISTANCE 1=No Effect 2=Little Effect 3=Affected 4=More Affected 5=Severely Affected Aromatic Solvents_________________ 1 Aliphatic Solvents__________________ 1 Chlorinated Solvents_______________ 1 Weak Bases_______________________ 1 Salts_____________________________ 1 Strong Bases______________________ 1 Salt Water 0-S-1926_________________ 1 Hydraulic Fluid MIL-H-5606__________ 1 Lube Oil MIL-L-7808________________ 1 De-Icing Fluid MIL-A-8243___________ 1 Strong Acids______________________ 2 Strong Oxidants___________________ 2 Esters/Ketones____________________ 1 UV Light_________________________ 2 Petroleum________________________ 1 Fungus ASTM G-21_________________ 1 Halogen Free____________________ Yes RoHS___________________________ Yes Minimum Continuous -94°F (-70°C) PHYSICAL PROPERTIES Monofilament Diameter_________ NA ASTM D-204 Flammability Rating___________ VW-1 Recommended Cutting________ Scissor Colors___________________________6 Wall Thickness_____________ .005”-.018” Specific Gravity ASTM D-792___ 1.0-1.8 Moisture Absorption_____________ .01 % ASTM D-570 TML___________________________.02 CVCM_________________________ .01 WVR___________________________ .00 Outgassing____________________ Low SVHC_________________________ None © 2021 Techflex® - Any unauthorized reproduction, in whole or part, in any medium whatsoever, without the express written permission of Techflex® is strictly forbidden. Techflex® product names and logos are registered trademarks of Techflex®, unless otherwise attributed. The contents and illustrations contained herein are believed to be reliable. Techflex® makes no warranties as to their accuracy or completeness and disclaims any liability in connection with their use. Techflex’s® only obligations are those in standard terms of sale for these products and Techflex® will not be liable for any consequential or other damages arising due to misuse of these products or typographical errors or omissions. 08-26 Users should make their own evaluation to determine the suitability of these products for their unique and specific applications. www.techflex.com Abrasion Resistance FLAMMABILITY 2,048°F (1,120°C)
FGLG.14RD 价格&库存

很抱歉,暂时无法提供与“FGLG.14RD”相匹配的价格&库存,您可以联系我们找货

免费人工找货