ATC-15

ATC-15

  • 厂商:

    EATON(伊顿)

  • 封装:

    -

  • 描述:

    FUSE AUTOMOTIVE 15A 32VDC BLADE

  • 数据手册
  • 价格&库存
ATC-15 数据手册
Low Voltage Supplementary Fuses RED indicates NEW information Section Contents Page Fuse Holder & Block Selection Guide . . . . . 72-73 Cable limiters & welder limiters K Series cable limiters . . . . . . . . . 600V . . . . . . . . . . 74 64000 & 68000 welder limiters . . . 600V . . . . . . . . . . 74 ⁄32˝ x 1 1⁄2˝ Fast-acting supplementary fuses BAF . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 75 KTK . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 75 KLM . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . 75 13 Low Voltage Supplementary Fuses 13 ⁄32˝ x 1 1⁄2˝ Time-delay supplementary fuses FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . 76 FNQ . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . 76 ⁄32˝ x 1 3⁄8˝ Fast-acting supplementary fuses BBS . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 77 13 Pin indication fuses and actuator GBA . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . GLD . . . . . . . . . . . . . . . . . . . . . . 125V . . . . . . . . . . MIC . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . MIN . . . . . . . . . . . . . . 250V fast-acting . . . . . . . . . . . FNA . . . . . . . . . . . . . . 250V time-delay . . . . . . . . . . MIS . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . KAZ . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . 78 78 78 78 78 79 79 Limiters ANN . . . . . . . . . . . . . . 125V fast-acting . . . . . . . . . 79 ANL . . . . . . . . . . . . . . 80Vdc time-delay . . . . . . . . . 79 4164 & 4164-FR . . . . . . . . . .fuse blocks . . . . . . . . . 79 In-line size rejecting fuses and fuse holders GLQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80 GMQ . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 80 In-line non-rejecting fuses and fuse holders GLR . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81 GMF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81 GRF . . . . . . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . 81 Automotive blade-type fuses ATC . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . ATC-_ID . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . ATM . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . ATM-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . ATM-LP . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . MAX . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . MAX-_ID . . . . . . . . . . . . . . . . . . . .32Vdc . . . . . . . . . 82 82 82 82 82 83 83 Automotive blade-type fuse holders HHC, HHD, HHF, HHG, ATC-FHID for ATC fuses . . . . 82 HHL, HHM, ATC-FHID for ATM fuses . . . . . . . . . . . . . 83 HHX for MAX fuses . . . . . . . . . . . . . . . . . . . . . . . . . . 83 PCB fuseclips for ATC/ATM blade, 5mm, 1⁄4˝ & 13⁄32˝ diameter fuses . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 71 Low Voltage Supplementary Fuses Holders & Blocks for Low Voltage Supplementary Fuses Limiters Catalog Number Volts Page K Series . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 68000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . 64000 Series . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . ANN Fast acting limiter . . . . . . . . . 125Vac/80Vdc . . . . . . . . . . . . ANL Time-delay limiter . . . . . . . . . 80Vdc . . . . . . . . . . . . . . . . . . 74 74 74 79 79 CH Series Holders • CH Series Class J modular 1 to 3-pole, panel/DIN rail mount . .283 • Safety J™ Series modular holders, panel/DIN rail mount . . . . . 288 Safety J™ Series Modular Type H250 Series H600 Series J600 Series Blocks • Modular Type Fuse Blocks 250/600V, panel mount . . . . . . . . . 311 • H250 Series 1- to 3-pole 250V, panel mount . . . . . . . . . . . . . .296 • H600 Series 1- to 3-pole 600V, panel mount . . . . . . . . . . . . . .299 Blocks • Modular Knifeblade Fuse Blocks 250/600V, panel mount . . . . • Modular Type Fuse Blocks 600V, panel mount . . . . . . . . . . . . • J600 Series, panel mount . . . . . . . . . . . . . . . . . . . . . . . . . . . • JP Series pyramid blocks, panel mount . . . . . . . . . . . . . . . . . • BH Series modular-style open blocks, panel mount . . . . . . . . 291 311 302 304 311 Modular Knifeblade Limiter Blocks - ANN & ANL • Blocks for 4164 & 4164-FR . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 JP Series BH Series 4164 & 4164-FR ⁄32˝ X 1 1⁄2˝ Fuses 13 Catalog Number Volts Page BAF . . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . KTK . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . . . . . KLM . . . . . . . . . . . . . . . . . . . . . . . 600Vac/dc . . . . . . . . . . . . . . . FNM . . . . . . . . . . . . . . . . . . . . . . 250V . . . . . . . . . . . . . . . . . . . FNQ . . . . . . . . . . . . . . . . . . . . . . . 500V . . . . . . . . . . . . . . . . . . . 75 75 75 76 76 Holders • • • • • • • • • • • • OPM-NG-SC3 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . .286 OPM-1038R 3-pole, panel/DIN-Rail mount . . . . . . . . . . . . . . . .285 OPM-1038RSW 3-pole w/ switch, panel/DIN-Rail mount . . . . .284 CH Series Global 1- to 3-pole, DIN-Rail mount . . . . . . . . . . . . .276 HPG Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . . .322 HPC-D Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . .323 HPM Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . . . . .323 HPS Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . .322 HPF Series Panel mount fuse holder . . . . . . . . . . . . . . . . . . . . 322 HEB Series 1-Pole in-line fuse holder . . . . . . . . . . . . . . . . . . . .315 HEX & HEY Series 2-Pole in-line fuse holders . . . . . . . . . . . . . 315 NDNF1-WH Fuse holding rail mount terminal block . . . . . . . . . 327 OPM-NG-SC3 OPM-1038R & OPM-1038RSW HPG HPS CH Series HPM HPC-D HPF HEB Series Blocks • BM Series, panel/DIN-Rail with adapters . . . . . . . . . . . . . . . . . 310 • 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . . 326 HEX & HEY Series 72 NDNF1-WH For product data sheets, visit www.cooperbussmann.com/DatasheetsEle BM Series Low Voltage Supplementary Fuses Holders & Blocks for Low Voltage Supplementary Fuses ⁄32˝ X 1 3⁄8˝ Fuses 13 Catalog Numbers Volts Page BBS . . . . . . . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 77 Holder • HPS-L Panel mount holder . . . . . . . . . . . . . . . . . . . . . . . . . . .322 Blocks • BM Series, panel/DIN rail with adapters . . . . . . . . . . . . . . . . . .310 • 3723, 3742 and 3743 multi-pole add-on fuse blocks . . . . . . . .326 BM Series HPS-L Pin Indicating Fuses ⁄4˝ X 11⁄4˝ Fuse Catalog Numbers 1 Volts Page Low Voltage Supplementary Fuses GBA 1⁄4" X 1 1⁄4" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 78 GLD 1⁄4" X 1 1⁄4" . . . . . . . . . . . . . . . . . . . . .125V . . . . . . . . . . . . . . . 78 MIC 13⁄32" X 1 1⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78 MIN 13⁄32" X 1 1⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78 FNA 13⁄32" X 1 1⁄2" . . . . . . . . . . . . . . . . . . . .250V . . . . . . . . . . . . . . . 78 MIS 13⁄32" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79 KAZ 13⁄32" X 2" . . . . . . . . . . . . . . . . . . . . . 600V . . . . . . . . . . . . . . . 79 HLD HK Series Holders • • ⁄4" X 1 1⁄4": HLD Panel mount visual indication . . . . . . . . . . . . .321 ⁄4" X 1 1⁄4": HK Series Panel mount lamp indicating . . . . . . . . . .321 1 1 Blocks • 1⁄4" X 1 1⁄4": Series 8000 for visual indication . . . . . . . . . . . . . . .324 • 13⁄32" X 1 1⁄2": 1-Pole signal block cat. # 3839 (not shown in catalog)* • 13⁄32" X 2": 1-Pole signal block cat. # 2778 (not shown in catalog)* • 13⁄32" X 2": 2-Pole signal block cat. # 2837 (not shown in catalog)* • 13⁄32" X 2": 3-Pole signal block cat. # 2838 (not shown in catalog)* *Call our customer satisfaction team at 636-527-3877 for more information. Series 8000 Automotive Blade-type Fuses Catalog Numbers Volts Page ATC . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 82 ATM . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 82 MAX . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Vdc . . . . . . . . . . . . . . 83 Holders • ATC: HHC, HHD, HHF, HHG & ATC-FHID In-line holders . . . . . . 82 • ATM: HHL, HHM & ATM-FHID In-line holders . . . . . . . . . . . . . 83 • MAX: HHX In-line holders . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83 easy ID™ Illuminating Holders HHC, HHD, HHF & HHG HHL & HHM HHX In-Line Rejecting and Non-Rejecting Fuses Catalog Number Volts Page GLQ rejecting fuse . . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 80 GMQ rejecting fuse . . . . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 80 GLR non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81 GMF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81 GRF non-rejecting fuse . . . . . . . . . . . . . 300V . . . . . . . . . . . . . . . 81 Holders • GLQ & GMQ: HLQ Rejection holder . . . . . . . . . . . . . . . . . . . . . 80 • GLR, GMF & GRF: HLR & HLR-2A non-rejection holders . . . . . .81 HLQ3 Fuse Holders For product data sheets, visitwww.cooperbussmann.com/DatasheetsEle HLR Fuse Holder 73 Low Voltage Supplementary Fuses Cable Limiters & Welder Limiters K Series 64000 & 68000 Series Specifications Description: Cable limiters. Ratings: Volts — 600Vac IR — 200kA RMS Sym. @ 600Vac Agency Information: UL Listing: KDM, KDR, KDP and KFM, KCM, KCM-B and KCR. Specifications Description: Welder limiters. Ratings: Volts — 600Vac (or less) IR — 200kA RMS Sym. Features and Benefits • Sizes and ratings available to meet many applications. Typical Applications • Protecting low voltage distribution and service entrance cables against short-circuit currents. Catalog Numbers Copper Cable Limiter — 600 Volts Catalog Number Tubular Terminals Cable Size Catalog Number KCY #4 KCF KCA #2 KCJ1, 2 KCZ KCB KCC KCD1, 2 KCE #3 #1 4/0 KCH 250 MCM KCM1, 2, 3, KCM-B1 500 MCM 1/0 KCV 3/0 KCS 2/0 Cable Size KCR1, 350 MCM 600 MCM 750 MCM 2 1000 MCM Tubular Terminal and Offset Bolt-Type Terminal KQV #12 KDD1 KFZ #8 KDF #4 KDJ1, 2 KQT KIG KDY KDA KDB KDC #10 #6 #2 #1 1/0 3/0 KDM1, 2, KDU KFH-A 4/0 250 MCM Typical Applications • Welder circuits • Because welder limiters have special characteristics, they are not intended for application on general-use circuits Catalog Numbers Catalog Fuse Holder Numbers Type 68300 Class H 68600 Class H 64300 Class J 64200 Class J Nominal Amp Rating 300 600 200 300 4/0 KDH 250 MCM 3 KDR1,2 Compression Connector Rod and Tubular Terminals KEX 2/0 KDE Features and Benefits • Current-limiting devices designed specially for use on welder circuits only • Time-current characteristics are designed to hold on the intermittent overloading encountered in welder operation, while providing short-circuit protection to the circuit and equipment • Welder limiters have excess current capacity in the operating range as needed for this type of service KQO KDT2 350 MCM 500 MCM 600 MCM 750 MCM 350 MCM 500 MCM *Center Bolt-Type Terminal and Off-Set Bolt-Type Terminal KPF KFT1 KEW1 4/0 250 MCM 350 MCM KDP1 KFM1 500 MCM 750 MCM *Copper or aluminum cable; sizes of all other limiters pertain to copper only. KFM copper only. UL Listed (File E90818). Available with shrink tube “_V” suffix. 3 Available with molded rubber boots. Add “–B” to end of part number. 1 2 Accessories Boots can be purchased separately. For KCM BOOT-KCM For KDM BOOT-KDM Installation tools can be purchased separately from Thomas and Betts • Crimp Tool: TBM-14M • Die: 15506 KDM/15515 KDR Recommended Fuse Blocks For 68000 & 64000 Series limiters • See page 72 Data Sheet: 1042 74 Data Sheet: 1045 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Low Voltage Supplementary Fuses 13 ⁄32˝ x 1 1⁄2˝ Fast-acting Fuses BAF KTK KLM Typical Applications Features and Benefits • Control Circuits • Low cost supplemental protection of • Lighting Circuit Protection 125V and 250V non-inductive circuits. • Meter Circuits • Upgrade with LP-CC product to reduce SKU investment and minimize potential Catalog Numbers (Amps) 600Vac - UL Listed and CSA arc-flash hazards. (and minimize KTK- ⁄ KTK- ⁄ KTK-4 KTK-12 potential for misapplying fuse.) 1 10 3 4 KTK- 1⁄8 KTK-1 KTK-5 KTK-15 KTK- 2⁄10 KTK-1- 1⁄4 KTK-6 KTK-20 KTK- 1⁄4 KTK-1- 1⁄2 KTK-7 KTK-25 KTK- 3⁄10 KTK-2 KTK-7- 1⁄2 KTK-30 KTK- 4⁄10 KTK-2- 1⁄2 KTK-8 KTK-35* KTK- 1⁄2 KTK-3 KTK-9 KTK-40* Catalog Numbers (Amps) KTK- 6⁄10 KTK-3- 1⁄2 KTK-10 KTK-45* BAF- ⁄4 BAF-2- ⁄2 BAF-9 *Rated for no more than 24A continuous. BAF-1⁄2 BAF-3 BAF-10 BAF- ⁄10 BAF-4 BAF-12 Typical Applications • General Purpose Circuits • Lighting Circuit Protection • Meter Circuits 1 6 1 BAF-8⁄10 BAF-5 BAF-15 BAF-1 BAF-6 BAF-20 BAF-1-1⁄2 BAF-6-1⁄4 BAF-25 BAF-1-8⁄10 BAF-7 BAF-30 BAF-2 BAF-8 KTK-50* Specifications Class: Supplemental Description: Full range, fast-acting, DC midget fuse. Dimensions: 13⁄32˝ x 1 1⁄2˝ (10.3 X 38.1mm). Ratings: Volts — 600Vac/dc Amps — 1⁄10-30A IR — 100kA AC — 50kA DC Agency Information: CE, UL Listed: STD. 248-14, (FILE #E19180), CSA Certified, C22.2 NO. 248. 14 (CLASS #1422-01, FILE #53787). Low Voltage Supplementary Fuses Specifications Specifications Class: Supplemental Class: Supplemental Description: FastDescription: Fast-acting acting supplementary supplementary fuse. fuse. 13 1 Dimensions: ⁄32˝ x 1 ⁄2 ˝ Dimensions: 13⁄32˝ x (10.3 x 38.1mm). 1 1 ⁄2 ˝ (10.3 x 38.1mm). Ratings: Ratings: Volts — 250Vac (or less) Volts — 600Vac (or Amps — 2⁄10-30A less) IR — 10kA @ 125Vac 1 ⁄10-30A Amps — 2 ( ⁄10-30A) IR — 100kA RMS Sym. (UL) — 35A (2⁄10-1A @ 250Vac) Agency Information: CE, Std. 248-14, 1 — 100A (1 ⁄2-3A @ 250Vac) UL Listed, Guide JDYX, File E19180. — 200A (4-10A @ 250Vac) Features and Benefits — 750A (12A- 15A @ 250Vac) • Low cost supplemental protection of 600V — 200A (20-30A @ 250Vac) or less non-inductive circuits. Agency Information: CE, Std. 248-14, UL 0-15/250V, Guide JDYX, File E19180 • Upgrade with LP-CC product to reduce SKU investment and minimize potential CSA Certified, 0-15/250V, Class arc flash hazards. 1422-01, File 53787. Features and Benefits • Full range, fast-acting, 600Vac/dc midget fuse. • Minimum interrupting rating or 200% rated current at 600Vdc. Typical Applications • DC Control Circuits Requiring Fast-Acting Fuses. • Solar power energy sources - use the Bussmann PVM fuse for DC ratings up to 600Vdc. Catalog Numbers (Amps) - KLM KLM-1⁄10 KLM- 3⁄4 KLM-5 KLM- 1⁄8 KLM-1 KLM-6 KLM-20 KLM-25 KLM- 2⁄10 KLM-1- 1⁄2 KLM-8 KLM-30 KLM- 1⁄4 KLM-2 KLM-10 KLM- 3⁄10 KLM-3 KLM-12 KLM- 1⁄2 KLM-4 KLM-15 *All have interrupting rating of 10,000A at 125V. For superior electrical protection, Bussmann recommends upgrading BAF and fuse applications to Low-Peak LP-CC fuses See page 23. Data Sheet: 2011 (0-30) For superior electrical protection, Bussmann recommends upgrading KTK fuse applications to Low-Peak LP-CC fuses See page 23. Data Sheet: 1011 Data Sheet: 2020 • See page 72 Recommended fuse blocks/fuse holders for 13⁄32” x 1 1⁄2” fuses For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 75 Low Voltage Supplementary Fuses 13 ⁄32˝ x 1 1⁄2˝ Time-delay Fuses FNM FNQ Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 13⁄32˝ x 11⁄2˝ (10.3 x 38.1mm). Ratings: Volts — 250Vac (or less) Amps — 1⁄10-30A IR — 35A (1⁄10-1A @ 250Vac) — 100A (11⁄8-31⁄2A @ 250Vac) — 200A (4-10A @ 250Vac) — 10kA (1⁄10-10A @ 125Vac) — 10kA (12-30A @ 250Vac) Agency Information: CE, Std. 248-14, UL Listed, 0-30/250Vac; File E19180, Guide JDYX, CSA Certified, 1-30/250Vac; Class 1422-01, File 53787. Specifications Class: Supplemental Description: Time-delay supplementary fuse. Dimensions: 13⁄32˝ x 11⁄2˝ (10.3 x 38.1mm). Ratings: Volts — 500Vac (or less) Amps — 1⁄10-30A IR — 10kA RMS Sym. Agency Information: CE, Std. 248-14, UL Listed, Guide JDYX, File E19180 CSA Certified, Class 1422-01, File 53787. Features and Benefits • Low cost supplemental protection of 125V and 250V inductive circuits. Typical Applications • General Purpose Circuits • Lighting Circuit Protection • Meter Circuits • Upgrading to LP-CC product will reduce SKU investment and minimize potential for misapplying fuse Features and Benefits • Low cost supplemental protection of transformers and relays at 500V or less. Typical Applications • Control Transformer 480V Primary Protection • Lighting Circuit Protection • Meter Circuits Catalog Numbers (Amps) FNQ-1⁄10 FNQ-4⁄10 FNQ-1-1⁄2 FNQ-3-1⁄2 FNQ-7 FNQ-1⁄8 FNQ-1⁄2 FNQ-1-6⁄10 FNQ-4 FNQ-8 FNQ-25 FNQ-15⁄100 FNQ-6⁄10 FNQ-2 FNQ-4-1⁄2 FNQ-9 FNQ-30 FNQ-3⁄16 FNQ-8⁄10 FNQ-2-1⁄4 FNQ-5 FNQ-10 FNQ- ⁄10 FNQ-1 FNQ-2-1⁄2 FNQ-5-6⁄10 FNQ-12 FNQ-1⁄4 FNQ-1-1⁄8 FNQ-3 FNQ-6 FNQ-14 FNQ-3⁄10 FNQ-1-1⁄4 FNQ-3-2⁄10 FNQ-6-1⁄4 FNQ-15 2 FNQ-20 Catalog Numbers (Amps) FNM-1⁄10 FNM-1⁄2 FNM-1-1⁄2 FNM-3 FNM- ⁄8 FNM- ⁄10 FNM-1- ⁄10 FNM-3- ⁄10 FNM-6- ⁄4 FNM-15⁄100 FNM-3⁄4 FNM-1-8⁄10 FNM-3-1⁄2 FNM-7 FNM-25 FNM-2⁄10 FNM-1 FNM-2 FNM-4 FNM-8 FNM-30 FNM-1⁄4 FNM-1-1⁄8 FNM-2-1⁄4 FNM-4-1⁄2 FNM-9 FNM- ⁄10 FNM-1- ⁄4 FNM-2- ⁄2 FNM-5 FNM-10 FNM-4⁄10 FNM-1-4⁄10 FNM-2-8⁄10 FNM-5-6⁄10 FNM-12 1 3 6 6 1 1 FNM-6 2 FNM-15 1 FNM-20 For superior electrical protection, Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 23. Recommended fuse blocks and fuse holders for 13 ⁄32˝ x 1 1⁄2˝ fuses • See page 72 Data Sheet: 2028 76 For superior electrical protection, Bussmann recommends upgrading FNM and FNQ fuse applications to Low-Peak LP-CC fuses See page 23. Recommended fuse blocks and fuse holders for 13 ⁄32˝ x 1 1⁄2˝ fuses • See page 72 Data Sheet: 1012 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Low Voltage Supplementary Fuses 13 ⁄32˝ x 1 3⁄8˝ Fast-acting Fuses BBS Low Voltage Supplementary Fuses Specifications Class: Supplemental Description: Fast-acting supplementary fuse. Dimensions: 13⁄32˝ x 13⁄8˝ (10.3 x 34.9mm). Construction: Fiber cartridge. Ratings: Volts — 600Vac (1⁄10-5A) — 250Vac (6 - 10A) — 48Vac (12-30A) Amps — 1⁄10-30A IR — 10kA RMS Sym. Agency Information: CE, Std. 248-14, UL Listed, 0-5A/600V, Guide JDYX, File E19180, CSA Certified, 0-5A/600V, Class 1422-01, File 53787. Features and Benefits • Low cost supplemental protection of non-inductive circuits • Reduced interchangeability with other supplemental fuses minimizes misapplication Typical Applications • Control Circuits • Lighting Ballasts • Meter Circuits Catalog Numbers (Amps) BBS-1⁄10 BBS-8⁄10 BBS-4 BBS-2⁄10 BBS-1 BBS-5 BBS-15 BBS-20 BBS-1⁄4 BBS-1-1⁄2 BBS-6 BBS-25 BBS-4⁄10 BBS-1-6⁄10 BBS-7 BBS-30 BBS-1⁄2 BBS-1-8⁄10 BBS-8 BBS-6⁄10 BBS-2 BBS-10 BBS-3⁄4 BBS-3 BBS-12 • Page 73 Recommended fuse blocks/fuse holders for 13⁄32˝ x 1 3⁄8˝ fuses Data Sheet: 2010 (0-30A) For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 77 Low Voltage Supplementary Fuses Pin Indication Fuses GBA MIC & MIN FNA GLD Specifications Class: Supplemental Description: Fastacting, pin indication fuse. Dimensions: 13 ⁄32˝ x 1 1⁄2˝ (10.3 x 38.1mm) 5AG. Ratings: Volts — 250Vac (1-15A) — 32Vac (20-30A) Amps — 1-30A IR — 35A (1A @250Vac) — 100A (2-3A @250Vac) — 200A (5-10A @250Vac) — 750A (15A @250Vac) — 10kA (20-30A @32V) — 35A (1A @250Vac) Agency Information: CE, Std. 248-14, MIC—0-15A UL Listed, 125Vac/10kA IR Guide JDYX, File E19180, MIN—1-5A CSA Certified, Class 1422-01, File 53787. Specifications Class: Supplemental Description: Time-delay, pin indication fuse. Dimensions: 13⁄32˝ x 1 1⁄2˝ (10.3 x 38.1mm). Ratings: Volts — 250Vac (1⁄10-8⁄10A) — 125Vac (1-15A) — 32Vac (20-30A) Amps — 1⁄10-30A IR — 35A (1⁄10-8⁄10A @ 250Vac) — 10kA (1⁄10-15A @ 125Vac) — 1kA (20-30A @ 32V) Agency Information: CE, Std. 24814, UL Listed 1⁄10-8⁄10A, IR 35A@ 250V, IR 10kA@ 125V , 1-15A, IR 10kA@ 125V, Guide JDYX, File 19180, CSA Certified, 0-8⁄10A/250V, 1-10A/125V, Class 1422-01, File 53787. Specifications Class: Supplemental Description: Fast-acting, pin indication fuse. Dimensions: 1⁄4˝ x 1 1⁄4˝ (6.6 x 31.7mm) 3AG. Ratings: Volts — See Agency Info below Amps — 1⁄2-15A IR — See Agency Info below Agency Information: CE, Std. 24814, UL Listed, 0-5A/125Vac, 10,000 AIC, Guide JDYX, File E19180, UL Recognized, 6A/125Vac, 1000AIC 8-15A/50Vac/dc, 300 AIC Guide JDYX2, File E19180, CSA Certified: 0-5A/125Vac, 10,000 AIC Class 1422-01, File 53787. Features and Benefits • Type GBA has a “red” pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime). • Type GLD has a plated pin to activate transmitting a electrical signal to indicate the location of opened circuits, resulting in reduced downtime. Typical Applications • Control Circuits • Electronic Circuits GLD Catalog Numbers (Amps) GLD-1⁄2 GLD-2 GLD-6 GLD-3⁄4 GLD-3 GLD-10 GLD-1 GLD-4 GLD-12 GLD-1-1⁄2 GLD-5 GLD-15 Features and Benefits • Type MIN has a “red” pin indicator providing visual identification of failed circuits, resulting in faster trouble shooting (reduced circuit downtime). • Type MIC has silver-plated pin transmitting an electrical signal indicating location of a failed circuit, resulting in faster troubleshooting (reduced circuit downtime). Typical Applications • Control Circuits • PLC Circuits • Electronic Circuits MIC Catalog Numbers (Amps) MIC-1 MIC-5 MIC-20 GBA Catalog Numbers (Amps) MIC-2 MIC-10 MIC-25 GBA-1⁄2 GBA-2 GBA-8 MIC-3 MIC-15 MIC-30 GBA-3⁄4 GBA-3 GBA-10 GBA-1 GBA-4 GBA-15 GBA-1-1⁄2 GBA-5 MIN-1 MIN-5 MIN-20 MIN-2 MIN-10 MIN-25 MIN-3 MIN-15 MIN-30 Recommended signal block for 13 ⁄32˝ x 1 1⁄2˝ indicating fuses Data Sheet: 2012 Data Sheet: 2047 78 Typical Applications • Control Circuits • Electronic Circuits Catalog Numbers (Amps) FNA-1⁄10 FNA-1⁄8 FNA-15⁄100 FNA-2⁄10 FNA-1⁄4 FNA-3⁄10 FNA-4⁄10 FNA-1⁄2 FNA-6⁄10 FNA-3⁄4 FNA-8⁄10 FNA-1 FNA-1-1⁄8 FNA-1-1⁄4 FNA-1-4⁄10 FNA-1-1⁄2 FNA-1-6⁄10 FNA-1-8⁄10 FNA-2 FNA-2-1⁄4 FNA-2-1⁄2 FNA-2-8⁄10 FNA-3 FNA-3-2⁄10 FNA-3-1⁄2 FNA-4 FNA-4-1⁄2 FNA-5 FNA-5-6⁄10 FNA-6 FNA-6-1⁄4 FNA-7 FNA-8 FNA-9 FNA-10 FNA-12* FNA-15* FNA-20* FNA-25* FNA-30 *12-30A versions are dual-tube construction MIN Catalog Numbers (Amps) Recommended fuse blocks/fuse holders for 1⁄4˝ x 1 1⁄4˝ indicating fuses • Page 73 Features and Benefits • FNA has a pin indicator providing visual identification of failed circuits, resulting in reduced circuit downtime. • Time-delay response allows close sizing on control transformers and relays • Page 73 Recommended signal block for • Page 73 ⁄32˝ x 1 1⁄2˝ indicating fuses 13 Data Sheet: 2029 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Low Voltage Supplementary Fuses Pin Indication Fuse and Actuator, and Limiters ANN & ANL Limiters Features and Benefits • Fast-acting circuit protection (ANN). • Time-delay sizing for inductive circuits (ANL). • Window shows limiter status. Typical Applications • Fork lifts, Marine, Aviation ANN Catalog Numbers (Amps) ANN-10 ANN-90 ANN-225 ANN-400 ANN-35 ANN-100 ANN-250 ANN-500 ANN-40 ANN-125 ANN-275 ANN-600 ANN-50 ANN-150 ANN-300 ANN-700 ANN-60 ANN-175 ANN-325 ANN-800 ANN-80 ANN-200 ANN-350 ANL Catalog Numbers (Amps) ANL-35 ANL-40 ANL-50 ANL-60 ANL-80 ANL-100 ANL-125 ANL-130 ANL-150 ANL-175 ANL-200 ANL-225 ANL-250 ANL-275 ANL-300 ANL-325 ANL-350 ANL-400 ANL-500 ANL-600 ANL-675 ANL-750 Data Sheets: 2023 (ANN), 2024 (ANL) KAZ Specifications Class: Supplemental Description: Non timedelay pin indication fuse. Dimensions: 13⁄32˝ x 2˝ (10.3 x 50.8mm). Ratings: Volts — 600Vac Amps — 1-12A IR — 200kA Features and Benefits • Type MIS has a pin indicator providing visual identification of failed circuits, resulting in faster troubleshooting (reduced circuit downtime). • Type MIS can be used in circuits rated 600V or less. • Type MIS has an interrupting rating of 200kA. Typical Applications • 480V Control Circuits • PLC Circuits Catalog Numbers (Amps) MIS-1 MIS-2 MIS-3 MIS-4 MIS-5 MIS-8 MIS-10 MIS-12 Specifications Description: Non-fuse actuator. Dimensions: 13⁄32˝ x 2˝ (10.3 x 50.8mm). Ratings: Volts — 600Vac Amps — N/A IR — 200kA Agency Information: CE, UL Listed, Guide JDVS, File E58836. Low Voltage Supplementary Fuses Specifications Description: Circuit limiters. ANN: Very fast-acting limiter. ANL: Non-time delay limiter. Dimensions: 7⁄8˝ x 3 3⁄16˝ (22.2 x 81.0mm). Ratings: ANN: Volts — 125Vac — 80Vdc Amps — 10-800A IR — 2500A @ 125Vac — 2700A @ 80Vdc ANL: Volts — 80Vdc Amps — 35-750A IR — 2700A @ 80Vdc Agency Information: ANN: 35-400A @ 125Vac, IR=2500A and 500A @ 80Vdc, IR=2700A: UL Recognized Guide JFHR2, File E56412; CSA Certified Class 1422-30, File 53787, CE for 35-400A. ANL: UL Recognized, CSA Certified, 35-750A @ 80Vdc, IR = 2700A, Guide JFHR2, File E56412, Class 1422-30, File 53787, SAE J1171. MIS Features and Benefits • Bussmann signal blocks 2778, 2837 or 2838 with KAZ actuators mounted in parallel with fuses having a rating of 50A or larger to provide blown fuse dropout of shunt-trip fused switches. • Type KAZ can be used in circuits rated 600V or less. • Type KAZ has an interrupting rating of 200kA. Typical Applications • Large, Shunt-Trip Fused Switches • Fuse Protected Circuits Rated 50A or Larger With Shunt-Trip Devices. Catalog Number: KAZ Test Specifications Fuse Load Opening Time All 110% 0 4 hrs. (min.) 1-5A 150% 0 6 min. (max.) 6-12A 150% 12 min. (max.) Recommended signal block for ⁄32˝ x 2˝ indicating fuses • Page 73 13 Recommended signal block for 13 ⁄32˝ x 2˝ indicating fuses • Page 73 Data Sheet: 2021 4164 & 4164-FR Limiter Blocks Specifications Description: Limiter fuse blocks for ANL & ANN. • 4164 furnished with nylon inserted locknuts • 4164-FR furnished with standard hex nuts Dimensions: Length: 3.38˝ Width: 0.95˝ Height: 1.62˝ Studs center to center: 2.43˝ Ratings: Volts — 125Vac — 80Vdc — 32Vdc (Self Certified) Amps — 10-800A Poles: 1 - stud terminal Data Sheet: 2133 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 79 Low Voltage Supplementary Fuses In-line Size Rejecting Fuses and Fuse Holders GLQ GMQ Specifications Class: Supplemental Description: Fast-acting, size-rejecting in-line fuse. Construction: Glass tube. Ratings: Volts — 300Vac (or less) Amps — 1-10A IR — 10kA Agency Information: CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787). Class: Supplemental Features and Benefits • In-Line, fast-acting circuit protection. • Rejection feature prevents overfusing. Features and Benefits Catalog Numbers (Amps) and Rejection Holders Holder1, 2 HLQ-1-6⁄1 0 HLQ-1-6⁄1 0 HLQ-1-6⁄1 0 HLQ-3 -2⁄1 0 HLQ-3 -2⁄1 0 Fuse GLQ-3 GLQ-4 GLQ-5 GLQ-9 GLQ-10 Holder1, 2 HLQ-3 -2⁄1 0 HLQ-5 HLQ-5 HLQ-10 HLQ-10 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042”. • Do not put tension on line (rear) terminal of fuse holder. Data Sheet: 2033 Description: Time-delay, size-rejecting in-line fuse. Construction: Ceramic tube. Ratings: Volts — 300Vac (or less) Amps — 1⁄2-61⁄4A IR — 10kA Agency Information: CE, Std. 248-14, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787) • In-line, fast-acting circuit protection. • Rejection feature prevents overfusing. Typical Applications • In-line Lighting Ballast Protection Fuse GLQ-1 GLQ-1-1⁄2 GLQ-1-6⁄1 0 GLQ-2 GLQ-2 -1⁄2 Specifications Typical Applications • In-Line Lighting Ballast Protection Catalog Numbers (Amps) and Rejection Holders Fuse Holders1, 2 Fuse Holders3, 4 GMQ-1⁄2 HLQ-1⁄2 GMQ-2-1⁄2 HLQ-3 -2⁄10 GMQ-6⁄10 HLQ-1-6⁄10 GMQ-3 HLQ-3 -2⁄10 GMQ- ⁄10 HLQ-1- ⁄10 GMQ-3 - ⁄10 HLQ-3 -2⁄10 GMQ-1 HLQ-1-6⁄10 GMQ-4 HLQ-5 GMQ-1-1⁄4 HLQ-1-6⁄10 GMQ-6 HLQ-8 GMQ-1-6⁄10 HLQ-1-6⁄10 GMQ-6 -1⁄4 GMQ-2 HLQ-3 -2⁄10 8 6 2 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 10A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030” to 0.042” • Do not put tension on line (rear) terminal of fuse holder. Data Sheet: 2030 3 HLQ Fuse Holders for both GLQ & GMQ fuses. 80 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Low Voltage Supplementary Fuses In-line Non-rejecting Fuses and Fuse Holders GMF Specifications Class: Supplemental Description: Fast-acting, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts — 300Vac (or less) Amps — 3⁄16-15A IR — 10kA Agency Information: CE, Std. 248-14, UL Listed, 0-15A/300Vac (Guide JDYX, File E19180), CSA Certified, 0-10A/300V (Class 1422-01, File 53787). GRF Features and Benefits • In-line, fast-acting circuit protection. Features and Benefits • In-line, time-delay circuits protection. Typical Applications • In-Line Lighting Ballast Protection Catalog Numbers (Amps) and Non-Rejection Holders Fuse GLR-1⁄2 GLR-1 GLR-1-1⁄2 GLR-1 -6⁄1 0 GLR-2 GLR-3 GLR-4 GLR-5 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR HLR Fuse GLR-6 GLR-7 GLR-8 GLR-9 GLR-10 GLR-12 GLR-15 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR-2A 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝. * For two leads (one each for line and loadside) order HLR-2A, 15A, 300V • • Specifications Class: Supplemental Description: Time-delay, non-rejection, in-line fuse. Construction: Glass tube. Ratings: Volts — 300Vac (or less) Amps — 3⁄10-10A IR — 10kA Agency Information: CE, Std. 248-14 0-10A, UL Listed (Guide JDYX, File E19180), CSA Certified, (Class 1422-01, File 53787). An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. Typical Applications • In-Line Lighting Ballast Protection Catalog Numbers (-Amps) and Non-Rejection Holders Fuse GMF-3⁄1 0 GMF-1⁄2 GMF-6⁄1 0 GMF-8⁄1 0 GMF-1 GMF-1-1⁄4 GMF-1-6⁄1 0 GMF-2 GMF-2 -1⁄2 GMF-2 -8⁄1 0 Fuse GMF-3 GMF-3 -2⁄1 0 GMF-4 GMF-5 GMF-6 -1⁄4 GMF-10 GRF-7 GRF-8 GRF-10 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR HLR HLR 1) Carrier is UL Recognized, Guide IZLT2, File E14853 and CSA Certified, Class 6225-01, File 47235 12A, 300Vac. 2) Units can be panel-mounted either in a knockout hole with a separate steel clip (BK/A-104) or in a keyhole punch using separate mounting clip #6374 for panels of thickness 0.043”to 0.062” or #4909 for thickness 0.030˝ to 0.042˝. *For two leads order HLR-2A, 15A, 300V • • Data Sheet: 2032 Holder1, 2* HLR HLR HLR HLR HLR HLR HLR HLR HLR HLR An alternative to the HLR fuse holder is the A fuse holder. The A fuse holder comes WITHOUT leads. The customer inserts #18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR. The A fuse holder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. Do not put tension on line (rear) terminal of fuse holder. Data Sheet: 2031 HLR-2A Fuse Holder HLR Fuse Holder For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 81 Low Voltage Supplementary Fuses GLR Low Voltage Supplementary Fuses Automotive Blade-type Fuses & Holders ATC Fuse (Actual Size) HHC, HHD, HHF, HHG & ATC-FHID Available With Indication LED Indicator Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts — 32Vdc Amps — 1-40A IR — 1000A Agency Information: UL Recognized, (3-40A) (Guide JFHR2, File E56412), SAE Standard J1284. Features and Benefits • Color coded plastic housing for easy identification of fuse ratings Typical Applications • Automotive Catalog Numbers (Amps) Non-Indicating *Indicating ATC-1 Black ATC-2 ATC-3 Gray ATC-3ID ATC-4 ATC-5 Color Violet easy ID™ LED Indicating Holder Specifications Description: In-line fuse holders for ATC™ Blade-Type fuses. Dimensions: See Dimensions illustration. Ratings: Volts: — 32Vdc Amps:— 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Catalog Numbers Catalog Numbers HHC HHD HHF HHG ATC-FHID Fuse Holder Description Yellow Black Black w/ cover Black w/ cover Indicating Holder Black w/ cover ATC-7-1/2ID Brown ATC-10 ATC-10ID Red ATC-15 ATC-15ID Blue ATC-20 ATC-20ID Yellow ATC-25 ATC-25ID Clear ATC-30 ATC-30ID Green ATC-35 ATC-35ID Blue-Green ATC-40 ATC-40ID Orange #16 black leadwire HHC & HHD Dimensions - in 0.78" Tan ATC-7-1/2 1-20 Electrical Connection #16 black leadwire #12 yellow leadwire #16 yellow leadwire #12 yellow leadwire A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. Pink ATC-5ID Fuse Amps 1-20 1-30 1-20 1-30 0.364" ATM Fuse Available With Indication ATM (Actual Size) ATM-LP Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts — 32Vdc Amps — 2-30A IR — 1000A Features and Benefits • Color coded plastic housing for easy identification of fuse ratings Typical Applications • Automotive Catalog Numbers (Amps) Non-Indicating *Indicating ATM-2 ATM-3 82 Color Gray ATM-3ID Violet ATM-4 Pink ATM-5 ATM-5ID ATM-5LP ATM-7-1/2 ATM-7-1/2ID ATM-7-1/2LP Brown ATM-10 ATM-10ID ATM-10LP Red ATM-15 ATM-15ID ATM-15LP Blue ATM-20 ATM-20ID ATM-20LP Yellow ATM-25 ATM-25ID ATM-25LP Clear ATM-30 ATM-30ID ATM-30LP Tan Green *Call Bussmann Customer Satisfaction for ordering information. 0.91" 0.38" 0.30" 0.5" 0.25" 4.0" + 0.25" 1.125" 4.0" + 0.25" *Call Bussmann Customer Satisfaction for ordering information. Data Sheet: 2009 Low-Profile Data Sheet: 2107 Data Sheet: 2048 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle Low Voltage Supplementary Fuses Automotive Blade-type Fuses & Holders HHL, HHM & ATM-FHID HHX MAX Maxi–Fuse Available With Indication LED Indicator (Actual Size) Specifications Description: In-line fuse holders for ATM Fuses. Ratings: Volts: — 32Vdc Amps: — 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Catalog Numbers Catalog Fuse Holder Numbers Description HHL Black w/ cover Fuse Electrical Amps Connection 2-20 #16 black leadwire, 4˝ length stripped to 1/4˝ 2-30 #12 red leadwire, 4˝ length stripped to 1/4˝ Features and Benefits • Color coded plastic housing for easy identification of fuse ratings Typical Applications • Automotive Specifications Description: In-line fuse holders for MAXI Fuses. Ratings: Volts: — 32Vdc Amps: — 80% continuous of fuse rating. See Catalog Numbers table for individual fuses sizes. Catalog Numbers Catalog Fuse Holder Numbers Description HHX Black w/ cover Fuse Amps 20-60 Electrical Connection #6 red leadwire, 5˝ with blunt ends Catalog Numbers (Amps) Non-Indicating *Indicating Color A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. A fuse must be properly and fully inserted into the holder to provide a solid connection. Poor or improper insertion of the fuse can result in failure of the fuse and holder, thus not protecting the device for which it was intended. MAX-20 MAX-20ID Yellow Dimensions - in HHL & HHM Dimensions - in HHM Black w/ cover ATM-FHID Indicating Holder Black w/ cover 2-20 #16 black leadwire 1.56" .25" 4.75" 4.75" .25" .59" .41" MAX-25 MAX-30 3.35" Gray MAX-30ID Green MAX-40 MAX-40ID Orange MAX-50 MAX-50ID Red MAX-60 MAX-60ID Blue MAX-70 MAX-70ID Tan MAX-80 MAX-80ID Clear MAX-35 Brown 6.70" 6.70" 1.37" .265" DIA. HOLE MAX-100ID Purple *Call Bussmann Customer Satisfaction for ordering information. Recommended in-line fuse holder for blade type fuses • Page 83 Data Sheet: 2128 Data Sheet: 2049 Low Voltage Supplementary Fuses easy ID™ LED Indicating Holder Specifications Description: Fast-acting blade fuse. Construction: Colored plastic housing with zinc fuse element. Ratings: Volts — 32Vdc Amps — 20-80A (non-indicating) 20-100A (indicating) IR — 1000A Data Sheet: 2129 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle 83 Low Voltage Supplementary Fuses Automotive Blade-type PCB Fuseclips ATM Fuses ATC Fuses (0 to 20 Amps) 1A5778 Series Dimensional Data 1A5600 Series Dimensional Data .295" 1.90 0.075 3.96 0.156 (7.49mm) .330" (8.38mm) (1.35mm) 1A5600 Cart. Brass Satin Finish Tin (2.03 ± 0.25mm) (5.08mm) (3.81mm) 1.57 0.062 3.18 0.125 .090" (2.29mm) Data Sheet: 2131 1.57 0.062 3.66 0.144 1A5780 Series Dimensional Data 2.18 0.086 1.65 ± 0.05 0.065 ± 0.002 (TYP-4) Finish 0.08" ± 0.01" .200" .150" 11.18 0.440 4.47 0.176 Clip Mat.* .053" 4.98 0.196 3.66 0.144 Catalog Number 3.66 0.144 19.30 0.760 4.45 0.175 DIA. HOLE 3.18 0.125 MOUNTING LAYOUT FOR 2 CLIPS BASE 6.88 0.271 FUSECLIPS MATERIAL: BRASS, NICKEL PLATED, 0.30 THICK 0.012 6.35 0.250 11.10 0.437 Data Sheet: 2131 1.27 0.050 1A5779 Series 14.68 0.578 1.24 0.049 5.08 0.200 4.06 0.160 5.08 0.200 4.75 0.187 2.54 ± 0.05 0.100 ± 0.002 (TYP-4) BASE MOUNTING LAYOUT FUSECLIPS 8.64 0.340 SPECIFICATIONS 3.18 0.125 1.45 0.057 DIA. HOLE 2.54 0.100 3.66 0.144 1.57 0.062 FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V-0 ..... CURRENT RATING . . . . . 15 AMPS VOLTAGE RATING . . . . . 500V AC TEMPERATURE RATING . . -50ºC TO 145ºC -58ºF 292ºF *Spg. Br. - Spring Bronze; BeCu - Beryllium Copper; Cart. Brass - Cartridge Brass 3.66 0.144 4.47 0.176 1.65 ± 0.05 0.065 ± 0.002 (TYP-4) 3.66 0.144 DIA. HOLE MOUNTING LAYOUT Data Sheet: 2131 84 SPECIFICATIONS FUSECLIPS . . . . . . . . BRASS, NICKEL PLATED BASE MATERIAL GLASS FILLED NYLON, UL RATED 94V-0 ..... CURRENT RATING . . . . . 15 AMPS VOLTAGE RATING . . . . . 500V AC -50ºC TEMPERATURE RATING . . -58ºF TO ***For RoHS compliant version add “-R” option code suffix to part number. 145ºC 292ºF Data Sheet: 2131 For product data sheets, visit www.cooperbussmann.com/DatasheetsEle
ATC-15 价格&库存

很抱歉,暂时无法提供与“ATC-15”相匹配的价格&库存,您可以联系我们找货

免费人工找货
ATC-15
    •  国内价格
    • 1+7.46673

    库存:279

    ATC-15
      •  国内价格
      • 1+19.08360
      • 10+18.65160
      • 30+18.36000

      库存:5

      ATC-15
      •  国内价格 香港价格
      • 5+27.631655+3.54758

      库存:0