Thermal automotive Mini-CBE 1620-...
Description
Single pole, thermal miniaturised circuit breaker designed for automotive
applications. Fits into fuse blocks designed to ISO 8820-3, Type F.
Automatic reset (for DC 12 V only) and open circuit (modified reset to
SAE) version optional. Open circuit version ensures contacts staying
open as long as power is on. The circuit breaker will reset after the
load is removed. Particularly suitable for installation in inaccessible
locations.
Current ratings correspond to those of blade fuses. Clear colour
coding of the ratings: blade fuse and circuit breaker of the same colour
have the same rating.
1
SAE type 1 SAE type 2 SAE type 3
Meets the requirements of SAE J553.
US patent number: US 8,576,042,B2
Technical data
Typical applications
Protection of electrical systems of passenger cars, trucks, buses,
watercraft, extra low voltage wiring systems.
Ordering information
Type No.
1620 single pole thermal Mini-CBE with standard characteristic curve
Version, according to SAE J553
1
type 1, automatic reset
2
type 2, modified reset
3
type 3, with reset button
Current ratings
5
7.5
10
15
20
25 30 A
1620 - 1 - 10 A ordering example
Please be informed that we have minimum ordering quantities to be
observed.
Current ratings, typical voltage drop values and colour coding
Current rating (A)
Voltage drop (mV)
Housing cap colour
5
< 150
light brown
7.5
< 150
brown
10
< 150
red
15
< 150
blue
20
< 150
yellow
25
< 150
white
30
< 150
light green
Note
The circuit breakers are marked with current rating, type and
maximum voltage. Special machine readability is not guaranteed.
For further details please
Voltage rating
Max. voltage rating
Current ratings
Service short-circuit
breaking capacity
see: www.e-t-a.de/ti_e
1620-1/-2: DC 12 V
1620-3: DC 12 V, DC 24 V
1620-1/-2: DC 14.5 V
1620-3: DC 29.0 V
DC 12 V: 5...30 A
DC 24 V: 5...25 A
Ambient temperature
Reset period for 1620-1
(at 23 °C)
Reset period for 1620-2
(at 23 °C) after 5 sec at
rated voltage
Degree of protection
(IEC 60529)
Ultimate short-circuit
breaking capacity
Vibration
Shock
Corrosion
Humidity
Mass
-40...+85 °C (-40…+185 °F)
(for higher temperatures please enquire)
300 operations at 2 x IN
≤ 15 s
< 35 s
operating area IP40 (-3)
operating area IP50 (-1, -2)
terminal area IP00
≥ 3 break operations at 150 A, or
≥ 1 break operation at 2,000 A
10 g (57-500 Hz), ± 0.38 mm (10-57 Hz)
to IEC 60068-2-6, test Fc
10 frequency cycles/axis
SAE-J553, Step No. 14, § 4.2.7.1.5
50 g (11 ms)
to IEC 60068-2-27, test Ea
SAE-J553, Step No. 14, § 4.2.7.1.6
48 hrs in 5 % salt mist,
to IEC 60068-2-11, test Ka
SAE-J553, Step No. 14, § 4.2.7.1.3
240 hrs in 95 % RH,
to IEC 60068-2-78, test Cab
SAE-J553, Step No. 14, § 4.2.7.1.2
approx. 3 g
Caution:
It is good practice to switch off the vehicle’s ignition system before
manually releasing or re-setting the circuit breaker. Free travel of the
reset button must be ensured! Please ensure to push in the actuator
smoothly and completely.
Depending on the socket used and with the 30 A device carrying a
full load, the temperatures at the terminals may rise above the allowed
SAE value.
2214
www.e-t-a.de
1
Thermal automotive Mini-CBE 1620-...
Dimensions
Internal connection diagrams
7
.276
1
1
2
2
1620-3H
1
1
2
2
1
10.4
.409
11.6
.457
GERMANY
2
.079
25
.984
13.3
.524
1620-3
1620-2
1620-1
1620-1 / 1620-2
Typical time/current characteristic curve at +23 °C / +73.4 °F
7.5
.295
5...30 A
4.5
.177
12.7
.500
1000
13.3
.524
3.5
.138
0.6
.024
1.8
.071
25
.984
2
.079
0.8±0.5 ON
.031±.019 ON
2
.079
4.5±0.5 OFF
.177±.019 OFF
1620-3
0.8
3.8 .032
.149
2.8
.110
trip time in seconds
2.8
10.9
.429
-40 °C
+85 °C
+23 °C
10000
100
10
1
GERMANY
11.6
.457
0.1
0.4 0.6 0.8 1
2
4
6 8 10
20
40
times rated current
The time/current characteristic curve depends on the ambient temperature
prevailing. In order to eliminate nuisance tripping, please multiply the
circuit breaker current ratings by the derating factor shown below. See also
section Technical information.
1620-3H
4.8
.189
13.3
.524
Ambient temperature °F
Ambient temperature °C
7
.275
3.5
.138
Derating factor
Ambient temperature °F
Ambient temperature °C
-4
-20
+14
-10
+32
0
+50
+10
0.73
0.78
0.82
0.86
0.91
0.95
+73.4
+23
+104
+40
+122
+50
+140
+60
+158
+70
+185
+85
1
1.09
1.16
1.25
1.33
1.43
24.95
.982
30.2
1.19
GERMANY
11.6
.457
-22
-30
0.8±0.5 ON
.031±.019 ON
4.5±0.5 OFF
.177±.019 OFF
Derating factor
-40
-40
This ist a metric design and millimeter dimensions take precedence (mm
inch)
All dimensions without tolerances are for reference only. In the interest of improved design,
performance and cost effectiveness the right to make changes in these specifications without
notice is reserved. Product markings may not be exactly as the ordering codes. Errors and
omissions excepted.
2
www.e-t-a.de
2214
很抱歉,暂时无法提供与“1620-1-15A”相匹配的价格&库存,您可以联系我们找货