1000 Eaton Boulevard
Cleveland, OH 44122
United States
SmartPro LCD 120V 1500VA 900W LineInteractive UPS, AVR, 2U Rack/Tower, LCD, USB,
DB9 Serial, 8 Outlets
Highlights
●
Supports a half-load (450W) up
to 11.8 min. during power
outage
●
Supports a full load (900W) up
to 4.4 min. during power outage
●
High 98% efficiency in line
power mode
●
Features 8 protected NEMA 515R outlets
●
Offers automatic voltage
regulation (AVR)
●
LCD screen reports real-time
UPS and power status
MODEL NUMBER: SMART1500LCD
Package Includes
Provides reliable 1500VA/900W power protection for your desktop computer, network workstation,
audio/video components or media center. Protects against surges, line noise, blackouts and brownouts.
Description
The SMART1500LCD SmartPro LCD 120V, 1500VA/900W Line-Interactive Uninterruptible Power Supply
provides battery backup and AC power protection against blackouts, brownouts, power surges and line
noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or
audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to
keep your connected equipment running long enough to save files and shut down safely with no data loss.
Eight NEMA 5-15R outlets protect against surges, as well as provide up to 11.8 minutes of UPS battery
support at half load (450W) and 4.4 minutes of support at full load (900W). Automatic voltage regulation
(AVR) corrects severe undervoltages as low as 75V and overvoltages as high as 147V without using any
battery power. EMI/RFI noise filtering improves your equipment's performance and prevents damage. A
870-joule surge suppression rating protects your equipment from harmful power surges.
NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket. Large rotatable LCD
screen with dimmer shows real-time input voltage, overload, AVR and battery statuses at a glance. Alarm
sounds to indicate power loss or low battery. With Tripp Lite's free PowerAlert software (available via free
download), the SMART1500LCD enables safe unattended system shutdown and file saves in case of a
prolonged power failure.
Features
Reliable Battery Backup
● Provides 1500VA/900W high-performance power protection for desktop computers, audio/video
components, media centers and other electronics
●
Supports 50% load (450W) up to 11.8 minutes and full load (900W) up to 4.4 minutes
●
Audible alarm indicates loss of utility power or low battery
●
Battery access door enables hot-swappable, user-replaceable internal batteries
Optimized Outlets
● 8 NEMA 5-15R outlets provide battery backup and protect against surges or spikes that can harm
equipment or data
1/6
●
SMART1500LCD UPS
●
USB cable
●
DB9 serial cable
●
Telephone cable
●
Mounting hardware
●
Owner’s Manual
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Automatic Voltage Regulation (AVR)
● Corrects undervoltages as low as 75V and overvoltages as high as 147V without drawing battery
backup power
Rotatable LCD Status Screen
● Large LCD screen offers real-time status information regarding operating mode, voltage, load level,
battery charge percentage and estimated runtime in minutes
●
UPS configuration options via front panel LCD include battery self-test, external battery pack
configuration, alarm on/off status and LCD brightness
●
Rotates for easy viewing in both horizontal and vertical installations
AC Line, Tel/DSL and Ethernet Surge Suppression
● Surge suppression rating of 870 joules protects connected equipment and data from harmful power
surges
●
Built-in RJ-45 jacks protect single-line tel/DSL or network Ethernet connection
EMI/RFI Line Noise Filtering
● Removes electromagnetic and radio frequency interference that can disrupt or damage your
equipment's performance
USB and DB9 Communication Ports and Free PowerAlert Software
● HID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and
Mac OS X
●
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert
software, available via FREE download from tripplite.eaton.com/products/power-alert
●
DB9 port also supports contact closure messaging for AC Present and AC Fail status
Flexible Installation Options
● NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket
●
Adapts to vertical or horizontal installation with included mounting hardware
●
Includes 2U brackets for rack-mount installation in 2 or 4 post racks
Specifications
OVERVIEW
UPC Code
037332126146
UPS Type
Line-Interactive
INPUT
Input Phase
Single-Phase
Rated input current (Maximum Load)
8.6A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-15P; Right-Angled
Input Circuit Breakers
10A
2/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
UPS Input Cord Length (ft.)
6
UPS Input Cord Length (m)
1.8
Recommended Electrical Service
15A 120V
OUTPUT
Output Capacity (VA)
1500
Output Capacity (kVA)
1.5
Output Capacity (Watts)
900
Output Capacity (kW)
0.9
Power Factor
0.6
Nominal Voltage Details
115v nominal output in battery mode
Frequency Compatibility
60 Hz
Output Voltage Regulation (Line
Mode)
-18%, +8%
Output Voltage Regulation (Battery
Mode)
115V (+/- 5%)
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery
Mode)
PWM sine wave
Nominal Output Voltage(s)
Supported
110V; 115V; 120V
Output Receptacles
(8) 5-15R
Individually Controllable Load Banks
No
BATTERY
Battery Type
Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)
4.4 min. (900W)
Runtime Half Load (min.)
11.8 min. (450W)
Expandable Runtime
No
DC System Voltage (VDC)
24
Battery Recharge Rate (Included
Batteries)
Less than 4.5 hours from 10% to 90%
Battery Access
Battery Access Door
Internal UPS Replacement Battery
Cartridge
RBC1500
Battery Replacement Description
IMPORTANT BATTERY REPLACEMENT INFORMATION > If your SMART1500LCD UPS has no battery
replacement door, please contact a local electronics repair technician to source and install a matching replacement
battery; If your SMART1500LCD UPS is equipped with a battery access door, please order Tripp Lite RBC1500
(quantity 1) replacement battery cartridge
VOLTAGE REGULATION
3/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147
Overvoltage Correction
Input voltages between 128 and 147 are reduced by 12%
Undervoltage Correction
Input voltages between 93 and 107 are boosted by 14%
Severe Undervoltage Correction
Input voltages between 75 and 92 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Backlighted LCD screen offers detailed UPS status information, configuration options and Error message reporting;
STATUS INFORMATION includes Input Voltage, Output Voltage, Estimated Runtime (minutes), Output Load
Percentage, Output Load Wattage, Battery Charge Percentage, Graphical 5-Bar Battery Charge Level and UPS
Operating Mode Display / CONFIGURATION OPTIONS include Power Sensitivity, LCD Status Information Scrolling,
Alarm Disable, LCD Brightness and Self Test / REPORTED ERROR MESSAGES include Replace-Battery and
Overload conditions; LCD Screen rotates for vertical or horizontal UPS placement
Switches
ON/OFF/MODE button provides UPS on/off power control (long-press) and advances the LCD screen display (short
tap); MUTE/ENTER button provides temporary alarm cancel, plus selection and confirmation of on-screen
configuration options
Alarm Cancel Operation
Press the MUTE/ENTER button during a power failure to silence the alarm; Once silenced, alarm will re-sound to
indicate low-battery status
Audible Alarm
Audible alarm indicates power-failure and low-battery status; Alarm can be disabled entirely via front panel LCD
interface (see manual)
LED Indicators
Front panel LCD display
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
870
UPS AC Suppression Response
Time
Instantaneous
UPS Dataline Suppression
1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet
UPS Dataline Suppression Details
168 joules; Compatible with POE applications
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Primary Form Factor
Rackmount
Rack Height
2U
Cooling Method
Fan
Included Mounting Accessory
Description
Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4
rubber-feet enable no-slip horizontal desktop placement
Installation Form Factors Supported
with Included Accessories
2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower
Minimum Required Rack Depth (cm)
35.56
Minimum Required Rack Depth
(inches)
14
Primary UPS Depth (mm)
267
Primary UPS Height (mm)
89
Primary UPS Width (mm)
438
4/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Shipping Dimensions (hwd / in.)
7.10 x 14.90 x 21.30
Shipping Dimensions (hwd / cm)
18.03 x 37.85 x 54.10
Shipping Weight (lbs.)
31.90
Shipping Weight (kg)
14.47
UPS Housing Material
ABS
UPS Power Module Dimensions
(hwd, cm)
8.89 x 43.82 x 26.67
UPS Power Module Dimensions
(hwd, in.)
3.5 x 17.25 x 10.5
UPS Power Module Weight (kg)
13.61
UPS Power Module Weight (lbs.)
30
Unit Weight (lbs.)
30.0000
Unit Weight (kg)
13.61
ENVIRONMENTAL
Operating Temperature Range
32° to 104°F (0° to 40°C)
Storage Temperature Range
5° to 122°F (-15° to 50°C)
Relative Humidity
Up to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
78
AC Mode Efficiency Rating (100%
Load)
98%
Operating Elevation (ft.)
6562
Operating Elevation (m)
2000
COMMUNICATIONS
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions; DB9 provides contact-closure notification of AC
Present (pins 1,9 connected) and AC Fail (pins 1,8 connected)
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at
https://tripplite.eaton.com/products/power-alert
Communications Cable
USB and DB9 Serial cabling included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network Management Card
Description
Network management not supported
Communications Interface
Contact closure; DB9 Serial; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time
4 milliseconds (AC to battery mode); 1 millisecond (Battery to AC mode)
Low Voltage Transfer to Battery
Power (Setpoint)
75
High Voltage Transfer to Battery
Power (Setpoint)
147
5/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS
STANDARDS & COMPLIANCE
Product Certifications
CSA (Canada); NOM (Mexico); UL 1778
Product Compliance
RoHS; FCC Part 15 Class B (USA)
WARRANTY & SUPPORT
Product Warranty Period (U.S. &
Canada)
3-year limited warranty
Product Warranty Period (Latin
America)
3-year limited warranty
Product Warranty Period
(International)
2-year limited warranty
Product Warranty Period (Mexico)
3-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime
Insurance
© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark. All other trademarks
are the property of their respective owners.