0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SMART1500LCDXL

SMART1500LCDXL

  • 厂商:

    TRIPPLITE

  • 封装:

    -

  • 描述:

    UPS SMART LCD AVR 120V EXT RUN

  • 数据手册
  • 价格&库存
SMART1500LCDXL 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States SmartPro LCD 120V 1500VA 900W LineInteractive UPS, AVR, Extended Runtime, 2U Rack/Tower, LCD, USB, DB9, 8 Outlets MODEL NUMBER: SMART1500LCDXL Highlights ● Supports a half-load (450W) up to 12 min. during power outage ● Supports a full load (900W) up to 4 min. during power outage ● Features 8 protected NEMA 515R outlets ● Offers automatic voltage regulation (AVR) ● Extends runtime with optional BP24V15RT2U external battery pack Package Includes Provides reliable 1500VA/900W power protection with expandable runtime for your desktop computer, network workstation, audio/video components or media center. Protects against surges, line noise, blackouts and brownouts. Description The SMART1500LCDXL SmartPro LCD 120V, 1500VA/900W Line-Interactive Uninterruptible Power Supply provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss. Eight NEMA 5-15R outlets protect against surges, as well as provide up to 12 minutes of UPS battery support at half-load (450W) and 4.18 minutes of support at full load (900W). You can get even more runtime by connecting an optional BP24V15RT2U external battery pack. Automatic voltage regulation (AVR) corrects severe undervoltages as low as 75V and overvoltages as high as 147V without using any battery power. EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 1038-joule surge suppression rating protects your equipment from harmful power surges. Space-saving NEMA 5-15P right-angle plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket. Large rotatable LCD screen shows real-time input voltage, load, AVR, remaining battery runtime and battery statuses at a glance. With Tripp Lite's PowerAlert software (available via free download), the SMART1500LCDXL enables safe unattended system shutdown and file saves in case of a prolonged power failure. Features Reliable Battery BackupProvides 1500VA/900W high-performance power protection for desktop computers, audio/video components, media centers and other electronicsSupports 50% load (450W) up to 12 minutes and full load (900W) up to 4.18 minutes97% full-load efficiency rating saves money in energy costsAudible alarm indicates loss of utility power, low battery and overload conditionsOptional BP24V15RT2U external battery pack easily connects for expanded runtime Optimized Outlets8 NEMA 5-15R outlets provide battery backup and protect against surges or spikes that can harm equipment or data Automatic Voltage Regulation (AVR)Corrects undervoltages as low as 75V and overvoltages as high as 147V without drawing battery backup power 1/6 ● SMART1500LCDXL SmartPro LCD 120V 1500VA/900W LineInteractive UPS ● USB cable ● DB9 serial cable ● Telephone cable ● Mounting hardware ● Owner’s Manual 1000 Eaton Boulevard Cleveland, OH 44122 United States Rotatable LCD Status ScreenLarge LCD screen shows real-time input voltage, load, AVR and battery statusesAutomatically displays remaining battery runtime in minutes during power outageRotates for easy viewing in both horizontal and vertical installationsBrightness control offers bright and dim selection options AC Line, Tel/DSL and Ethernet Surge SuppressionSurge suppression rating of 1038 joules protects connected equipment and data from harmful power surgesBuilt-in RJ-45 jacks protect single-line tel/DSL or network Ethernet connection EMI/RFI Line Noise FilteringRemoves electromagnetic and radio frequency interference that can disrupt or damage your equipment's performance USB and DB9 Communication Ports and Free PowerAlert SoftwareHID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and Mac OS XUSB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert Flexible Installation OptionsSpace-saving NEMA 5-15P right-angle plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socketAdapts to vertical or horizontal installation without special hardwareIncludes 2U brackets for rack-mount installation Specifications OVERVIEW UPC Code 037332159885 UPS Type Line-Interactive INPUT Input Phase Single-Phase Rated input current (Maximum Load) 8.6A Nominal Input Voltage(s) Supported 110V AC; 115V AC; 120V AC UPS Input Connection Type 5-15P; Right-Angled Input Circuit Breakers 10A UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Recommended Electrical Service 15A 120V OUTPUT Output Capacity (VA) 1500 Output Capacity (kVA) 1.5 Output Capacity (Watts) 900 Output Capacity (kW) 0.9 Power Factor 0.6 Nominal Voltage Details 115v nominal output in battery mode 2/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Frequency Compatibility 60 Hz Output Voltage Regulation (Line Mode) -18%, +8% Output Voltage Regulation (Battery Mode) +/- 5% Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 110V; 115V; 120V Output Receptacles (8) 5-15R Individually Controllable Load Banks No BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Runtime Full Load (min.) 4.18 min. (900W) Runtime Half Load (min.) 12 min. (450W) Expandable Runtime Yes Expandable Runtime Description Extended runtime supported via optional external battery pack (limit 1) External Battery Pack Compatibility  BP24V15RT2U  (limit 1) DC System Voltage (VDC) 24 Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% Battery Access Battery access door enables hot-swappable, user replaceable internal battery Internal UPS Replacement Battery Cartridge  RBC1500  VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 75 to 147 Overvoltage Correction Input voltages between 128 and 147 are reduced by 12% Undervoltage Correction Input voltages between 93 and 107 are boosted by 14% Severe Undervoltage Correction Input voltages between 75 and 92 are boosted by 30% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display LCD interface reports Input Voltage, Output Voltage, Battery Charge Percentage, Estimated Runtime in Minutes, Load Percentage, Load Watts; Additional LCD icons report battery charge level (5 "bars"), Line Power Mode, Battery Mode, Replace Battery and Auto-Voltage Regulation / AVR status; LCD interface control options include Alarm Disable, Display Scrolling, Initiate Self-test, LCD brightness, External Battery setting and line sensitivity Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status 3/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Audible Alarm Audible alarm indicates power-failure and low-battery conditions; Alarm can be permanently silenced via LCD interface SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 1038 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); 10/100Base T Ethernet EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Rackmount Rack Height 2U Cooling Method Fan Included Mounting Accessory Description Included mounting brackets enable installation in 2 and 4 post racks, plus upright tower configurations; Set of 4 rubber-feet enable no-slip horizontal desktop placement installation Installation Form Factors Supported with Included Accessories 2 post 19 inch rackmount; 2 post front mount; 4 post 19 inch rackmount; Tower Minimum Required Rack Depth (cm) 35.56 Minimum Required Rack Depth (inches) 14 Primary UPS Depth (mm) 267 Primary UPS Height (mm) 89 Primary UPS Width (mm) 439 Shipping Dimensions (hwd / in.) 7.40 x 15.00 x 21.20 Shipping Dimensions (hwd / cm) 18.80 x 38.10 x 53.85 Shipping Weight (lbs.) 33.20 Shipping Weight (kg) 15.06 UPS Housing Material Polycarbonate UPS Power Module Dimensions (hwd, cm) 8.89 x 43.94 x 26.67 UPS Power Module Dimensions (hwd, in.) 3.5 x 17.3 x 10.5 UPS Power Module Weight (kg) 13.34 UPS Power Module Weight (lbs.) 29.4 Unit Dimensions (hwd / in.) 3.500 x 17.250 x 10.500 Unit Weight (lbs.) 30.000 Unit Weight (kg) 13.61 ENVIRONMENTAL 4/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Operating Temperature Range 32° to 104°F (0° to 40°C) Storage Temperature Range 5° to 122°F (-15° to 50°C) Relative Humidity Up to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 78 Battery Mode BTU / Hr. (Full Load) 721 AC Mode Efficiency Rating (100% Load) 97% Operating Elevation (ft.) 6562 Operating Elevation (m) 2000 COMMUNICATIONS Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions; DB9 port also supports contact-closure messaging for power-fail (pins 1 & 9) and power-restored (pins 1, 8) PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert Communications Cable USB and DB9 Serial cabling included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stablehcl.html?manufacturer=Tripp%20Lite Network Management Card Description Network management not supported Communications Interface Contact closure; DB9 Serial; USB (HID enabled) LINE / BATTERY TRANSFER Transfer Time 4 milliseconds AC to battery mode / 3 milliseconds battery to AC mode Low Voltage Transfer to Battery Power (Setpoint) 75 High Voltage Transfer to Battery Power (Setpoint) 147 FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS STANDARDS & COMPLIANCE Product Certifications CSA (Canada); NOM (Mexico); UL 1778 Product Compliance RoHS; FCC Part 15 Class B (USA) WARRANTY & SUPPORT 5/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Product Warranty Period (Worldwide) 2-year limited warranty Product Warranty Period (U.S. & Canada) 3-year limited warranty Product Warranty Period (Latin America) 3-year limited warranty Product Warranty Period (International) 2-year limited warranty Product Warranty Period (Mexico) 3-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance  © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 6/6
SMART1500LCDXL 价格&库存

很抱歉,暂时无法提供与“SMART1500LCDXL”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SMART1500LCDXL
    •  国内价格 香港价格
    • 1+4461.592291+539.86337
    • 5+4164.153515+503.87257
    • 10+4042.2268410+489.11915

    库存:4