Eaton Tripp Lite series SmartPro 1950VA 1950W
120V Line-Interactive Sine Wave UPS - 7 Outlets,
Extended Run, Network Card Option, LCD, USB,
DB9, 2U Rack/Tower
MODEL NUMBER: SMART2200RMXL2U
Highlights
●
Protects equipment against
blackouts, brownouts, transient
surges and line noise
●
Keeps equipment running during
outages to allow time for file
saves and safe shutdown
●
Unity power factor ensures
maximum power possible at
each power rating
●
ENERGY STAR 2.0-certified to
save electricity, lower costs and
protect the environment
●
2-line front-panel LCD with 10
selectable screens reports
detailed UPS and site power
info
Package Includes
Provides complete battery backup and pure sine wave power output for servers, switches and other highend distributed IT equipment.
Features
1.95kVA/1.95kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments
This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection
against blackouts, brownouts, surges and line noise that can damage your IT equipment or destroy data.
The SMART2200RMXL2U is ideal power management for high-end in-rack networking equipment,
including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most
watts possible at each power rating, so you can connect more equipment.
Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages
The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power
failures and give you enough time to safely save files and shut down your system in case of a prolonged
blackout. Switchover from line to battery power happens within milliseconds to maintain continuous
operation of connected equipment without interruption or rebooting. Extra runtime is available by
connecting up to four optional extended battery modules (BP72VRM2U, sold separately).
Optional LX Platform Network Management Card Allows Remote Access 24/7
The WEBCARDLXE network interface (sold separately) enables full remote configuration and
management, including load shedding, reboots of connected equipment and safe shutdowns. The IPbased Auto Probe feature ensures continuous network uptime by communicating with other network
devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2
modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental
monitoring and control options.
NEMA Outlets Protect Your Connected Components
One L5-20R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output
and allow you to monitor power consumption down to the outlet group level. Power provided by these
outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R
outlets are split into two independently switchable load banks that let you shed non-critical loads to extend
runtime for critical loads. Front and rear cooling fans help protect equipment from overheating.
1/6
●
1950VA 1950W 120V LineInteractive UPS
●
USB cable
●
DB9 cable
●
Rack-mounting hardware
●
Tower support stands
●
Safety instructions
●
Advanced User Guide
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions
AVR protects your equipment from incremental hardware damage, data loss and performance problems
caused by brownouts. The SMART2200RMXL2U maintains regulated 120V nominal output during
brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take
over in case of power failure.
Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better
This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict
hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform
better and last longer.
ENERGY STAR-Certified to Help You Save Money and Protect the Environment
By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements,
this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU
emissions, save on utility and cooling costs and help protect the environment.
Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring
The two-line front-panel LCD monitoring screen features ten selectable screens that allow quick access to
a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means
utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active
alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations.
Advanced Communications Ports Allow for Automatic Saves and Shutdowns
RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A
dry-contact relay port can be programmed through the LCD to provide reliable communications to
automation and industrial components. The RPO/ROO port permits emergency shutdown or remote
restart of all connected equipment.
Versatile Installation Options
You can mount the SMART2200RMXL2U in just 2U of space in an EIA-standard 19-inch rack using the
included hardware. At 23.7 inches deep, the UPS mounts in short-depth racks and other compact spaces.
You can also adapt it for tower installation using the included support stands. The 10-foot power cord with
NEMA 5-20P plug connects to a compatible AC outlet.
Specifications
OVERVIEW
UPC Code
037332118059
UPS Type
Line-Interactive
INPUT
Rated input current (Maximum Load)
16.0A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-20P
UPS Input Cord Length (ft.)
10
UPS Input Cord Length (m)
3.1
Recommended Electrical Service
20A 120V
Input Phase
Single-Phase
OUTPUT
2/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Output Capacity (VA)
1950
Output Capacity (kVA)
1.95
Output Capacity (Watts)
1950
Output Capacity (kW)
1.95
Power Factor
1
Nominal Voltage Details
120v nominal output in battery mode
Frequency Compatibility
50 / 60 Hz
Output Voltage Regulation (Battery
Mode)
120V (-10%, +6%)
Load Management Receptacles
Two switched single outlet load banks (2x 5-20R and 2x 5-20R )
Output AC Waveform (AC Mode)
Pure Sine wave
Output AC Waveform (Battery
Mode)
Pure Sine wave
Nominal Output Voltage(s)
Supported
100V; 110V; 120V; 125V
Output Receptacles
(6) 5-20R; (1) L5-20R
Individually Controllable Load Banks
Yes
BATTERY
Battery Type
Valve Regulated Lead Acid (VRLA)
Runtime Full Load (min.)
4 min. (1950W)
Runtime Half Load (min.)
12 min. (975W)
Expandable Battery Runtime
Extended runtime supported via optional external battery packs
Expandable Runtime
Yes
External Battery Pack Compatibility
BP72VRM2U (limit 4)
DC System Voltage (VDC)
72
Battery Recharge Rate (Included
Batteries)
Less than 4.5 hours from 10% to 90% (typical, full load discharge)
Battery Access
Front panel battery access door
Internal UPS Replacement Battery
Cartridge
744-A4852
Battery Replacement Description
Hot-swappable, user replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Front panel rotatable LCD information and configuration screen offers detailed UPS and site power status and
operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see
manual for detailed LCD configuration and monitoring options)
3/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Switches
5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions
Alarm Cancel Operation
Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and
perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding
the previous alarm silencing
Audible Alarm
Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown
conditions
SURGE / NOISE SUPPRESSION
UPS AC Suppression Response
Time
Instantaneous
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Primary Form Factor
Rackmount; Tower
Rack Height
2U
Cooling Method
Fan
Included Mounting Accessory
Description
Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be
configured in an upright tower orientation.
Installation Form Factors Supported
with Included Accessories
4 post 19 inch rackmount; Tower
Minimum Required Rack Depth (cm)
68.58
Minimum Required Rack Depth
(inches)
27
Minimum Required Rack Depth with
External Battery Pack (cm)
67
Minimum Required Rack Depth with
External Battery Pack (in.)
26.5
Minimum Required Rack Depth
without External Battery Pack (cm)
69
Minimum Required Rack Depth
without External Battery Pack (in.)
27
Primary UPS Depth (mm)
602
Primary UPS Height (mm)
86
Primary UPS Width (mm)
437
Shipping Dimensions (hwd / in.)
9.40 x 22.80 x 30.90
Shipping Dimensions (hwd / cm)
23.88 x 57.91 x 78.49
Shipping Weight (lbs.)
78.50
Shipping Weight (kg)
35.61
UPS Housing Material
Steel
UPS Power Module Dimensions
(hwd, cm)
8.64 x 43.69 x 60.20
UPS Power Module Dimensions
(hwd, in.)
3.4 x 17.2 x 23.7
4/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Unit Dimensions (hwd / in.)
3.400 x 17.000 x 23.700
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
20 to 95%, non-condensing
AC Mode Efficiency Rating (100%
Load)
96%
COMMUNICATIONS
Network Management Cards
WEBCARDLXE
Network Monitoring Port Description
Network Card Optional
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at
https://tripplite.eaton.com/poweralert
Communications Cable
USB and DB9 cabling included
Network Management Card
Description
Network management card optional
Communications Interface
Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time
1-4ms for normal mode
Low Voltage Transfer to Battery
Power (Setpoint)
80
High Voltage Transfer to Battery
Power (Setpoint)
151
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management;
Sine wave output; Surge/noise protection
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS; Individually controllable load banks
STANDARDS & COMPLIANCE
Product Certifications
CSA (Canada); UL 1778
Product Compliance
CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class B (USA)
WARRANTY & SUPPORT
Product Warranty Period
(Worldwide)
2-year warranty, 3 year with registration. Note: Registration is required for 3-year