0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SMART2200RMXL2U

SMART2200RMXL2U

  • 厂商:

    TRIPPLITE

  • 封装:

    -

  • 描述:

    BATT BACKUP 2.2KVA 120V RACK MNT

  • 数据手册
  • 价格&库存
SMART2200RMXL2U 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton Tripp Lite series SmartPro 1950VA 1950W 120V Line-Interactive Sine Wave UPS - 7 Outlets, Extended Run, Network Card Option, LCD, USB, DB9, 2U Rack/Tower MODEL NUMBER: SMART2200RMXL2U Highlights ● Protects equipment against blackouts, brownouts, transient surges and line noise ● Keeps equipment running during outages to allow time for file saves and safe shutdown ● Unity power factor ensures maximum power possible at each power rating ● ENERGY STAR 2.0-certified to save electricity, lower costs and protect the environment ● 2-line front-panel LCD with 10 selectable screens reports detailed UPS and site power info Package Includes Provides complete battery backup and pure sine wave power output for servers, switches and other highend distributed IT equipment. Features 1.95kVA/1.95kW/120V Battery Backup for Distributed IT, Telecom or Enterprise Deployments This rack-mount line-interactive UPS system provides reliable battery backup and AC power protection against blackouts, brownouts, surges and line noise that can damage your IT equipment or destroy data. The SMART2200RMXL2U is ideal power management for high-end in-rack networking equipment, including servers, VoIP phones, data storage and PoE switches. Unity power factor ensures the most watts possible at each power rating, so you can connect more equipment. Reliable, Expandable Battery Backup Keeps You Operational Through Power Outages The field-replaceable, hot-swappable VRLA battery modules allow you to work through short power failures and give you enough time to safely save files and shut down your system in case of a prolonged blackout. Switchover from line to battery power happens within milliseconds to maintain continuous operation of connected equipment without interruption or rebooting. Extra runtime is available by connecting up to four optional extended battery modules (BP72VRM2U, sold separately). Optional LX Platform Network Management Card Allows Remote Access 24/7 The WEBCARDLXE network interface (sold separately) enables full remote configuration and management, including load shedding, reboots of connected equipment and safe shutdowns. The IPbased Auto Probe feature ensures continuous network uptime by communicating with other network devices, detecting lost connectivity and automatically rebooting IT equipment. Optional EnviroSense2 modules (E2MT, E2MTDO and E2MTHDI, all sold separately) provide a variety of environmental monitoring and control options. NEMA Outlets Protect Your Connected Components One L5-20R and six 5-20R managed outlets provide connected equipment with pure sine wave AC output and allow you to monitor power consumption down to the outlet group level. Power provided by these outlets is filtered to protect connected equipment against damaging surges and line noise. Four 5-20R outlets are split into two independently switchable load banks that let you shed non-critical loads to extend runtime for critical loads. Front and rear cooling fans help protect equipment from overheating. 1/6 ● 1950VA 1950W 120V LineInteractive UPS ● USB cable ● DB9 cable ● Rack-mounting hardware ● Tower support stands ● Safety instructions ● Advanced User Guide 1000 Eaton Boulevard Cleveland, OH 44122 United States Automatic Voltage Regulation (AVR) Corrects Low- and High-Voltage Conditions AVR protects your equipment from incremental hardware damage, data loss and performance problems caused by brownouts. The SMART2200RMXL2U maintains regulated 120V nominal output during brownouts and overvoltages from 80V to 151V while keeping the battery fully charged and ready to take over in case of power failure. Premium Protection from EMI/RFI Line Noise Helps Your Equipment Perform Better This UPS system filters out disruptive electromagnetic and radio frequency interference that can inflict hardware damage or data loss. This EMI/RFI filtering also helps your connected components perform better and last longer. ENERGY STAR-Certified to Help You Save Money and Protect the Environment By meeting strict U.S. Department of Energy and U.S. Environmental Protection Agency requirements, this ENERGY STAR 2.0 UPS system provides high operational efficiency to signal a reduction in BTU emissions, save on utility and cooling costs and help protect the environment. Intuitive Front-Panel Interface for Convenient UPS Operation and Monitoring The two-line front-panel LCD monitoring screen features ten selectable screens that allow quick access to a wide range of detailed UPS and site power information. LEDs show UPS status: a green light means utility power is on, an orange light means the UPS is in battery mode and a red light indicates an active alarm or fault. The control panel rotates to accommodate both rack-mount and tower configurations. Advanced Communications Ports Allow for Automatic Saves and Shutdowns RS-232 and USB ports connect to a device for a variety of communication options (cables are included). A dry-contact relay port can be programmed through the LCD to provide reliable communications to automation and industrial components. The RPO/ROO port permits emergency shutdown or remote restart of all connected equipment. Versatile Installation Options You can mount the SMART2200RMXL2U in just 2U of space in an EIA-standard 19-inch rack using the included hardware. At 23.7 inches deep, the UPS mounts in short-depth racks and other compact spaces. You can also adapt it for tower installation using the included support stands. The 10-foot power cord with NEMA 5-20P plug connects to a compatible AC outlet. Specifications OVERVIEW UPC Code 037332118059 UPS Type Line-Interactive INPUT Rated input current (Maximum Load) 16.0A Nominal Input Voltage(s) Supported 120V AC UPS Input Connection Type 5-20P UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 20A 120V Input Phase Single-Phase OUTPUT 2/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Output Capacity (VA) 1950 Output Capacity (kVA) 1.95 Output Capacity (Watts) 1950 Output Capacity (kW) 1.95 Power Factor 1 Nominal Voltage Details 120v nominal output in battery mode Frequency Compatibility 50 / 60 Hz Output Voltage Regulation (Battery Mode) 120V (-10%, +6%) Load Management Receptacles Two switched single outlet load banks (2x 5-20R and 2x 5-20R ) Output AC Waveform (AC Mode) Pure Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 100V; 110V; 120V; 125V Output Receptacles (6) 5-20R; (1) L5-20R Individually Controllable Load Banks Yes BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Runtime Full Load (min.) 4 min. (1950W) Runtime Half Load (min.) 12 min. (975W) Expandable Battery Runtime Extended runtime supported via optional external battery packs Expandable Runtime Yes External Battery Pack Compatibility  BP72VRM2U  (limit 4) DC System Voltage (VDC) 72 Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% (typical, full load discharge) Battery Access Front panel battery access door Internal UPS Replacement Battery Cartridge  744-A4852  Battery Replacement Description Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83 to 145 USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Front panel rotatable LCD information and configuration screen offers detailed UPS and site power status and operating data, plus configuration of voltage, operating mode, alarm function and a variety of additional options (see manual for detailed LCD configuration and monitoring options) 3/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Switches 5 pushbutton switches control OFF / ON power status, ENTER, UP, and DOWN selection and ESC control functions Alarm Cancel Operation Press the ESC (Escape) button on the front panel display to silence the alarm. Check the alarm condition and perform the applicable action to resolve the condition. If the alarm status changes, the alarm beeps again, overriding the previous alarm silencing Audible Alarm Audible alarm indicates UPS startup, power-failure, low-battery, overload, UPS fault and remote shutdown conditions SURGE / NOISE SUPPRESSION UPS AC Suppression Response Time Instantaneous EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Rackmount; Tower Rack Height 2U Cooling Method Fan Included Mounting Accessory Description Included mounting bracket enables installation in 4 post racks. Two ABS mounting stands enables the UPS to be configured in an upright tower orientation. Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount; Tower Minimum Required Rack Depth (cm) 68.58 Minimum Required Rack Depth (inches) 27 Minimum Required Rack Depth with External Battery Pack (cm) 67 Minimum Required Rack Depth with External Battery Pack (in.) 26.5 Minimum Required Rack Depth without External Battery Pack (cm) 69 Minimum Required Rack Depth without External Battery Pack (in.) 27 Primary UPS Depth (mm) 602 Primary UPS Height (mm) 86 Primary UPS Width (mm) 437 Shipping Dimensions (hwd / in.) 9.40 x 22.80 x 30.90 Shipping Dimensions (hwd / cm) 23.88 x 57.91 x 78.49 Shipping Weight (lbs.) 78.50 Shipping Weight (kg) 35.61 UPS Housing Material Steel UPS Power Module Dimensions (hwd, cm) 8.64 x 43.69 x 60.20 UPS Power Module Dimensions (hwd, in.) 3.4 x 17.2 x 23.7 4/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Unit Dimensions (hwd / in.) 3.400 x 17.000 x 23.700 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 20 to 95%, non-condensing AC Mode Efficiency Rating (100% Load) 96% COMMUNICATIONS Network Management Cards  WEBCARDLXE  Network Monitoring Port Description Network Card Optional PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at https://tripplite.eaton.com/poweralert Communications Cable USB and DB9 cabling included Network Management Card Description Network management card optional Communications Interface Contact closure; DB9 Serial; Slot for SNMP/Web interface; USB (HID enabled) LINE / BATTERY TRANSFER Transfer Time 1-4ms for normal mode Low Voltage Transfer to Battery Power (Setpoint) 80 High Voltage Transfer to Battery Power (Setpoint) 151 FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Automatic Voltage Regulation (AVR); Expandable battery backup; Hot swappable batteries; Remote management; Sine wave output; Surge/noise protection Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS; Individually controllable load banks STANDARDS & COMPLIANCE Product Certifications CSA (Canada); UL 1778 Product Compliance CE (Europe); ENERGY STAR Qualified; FCC Part 15 Class B (USA) WARRANTY & SUPPORT Product Warranty Period (Worldwide) 2-year warranty, 3 year with registration. Note: Registration is required for 3-year warranty. Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance  5/6 1000 Eaton Boulevard Cleveland, OH 44122 United States © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 6/6
SMART2200RMXL2U 价格&库存

很抱歉,暂时无法提供与“SMART2200RMXL2U”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SMART2200RMXL2U
    •  国内价格 香港价格
    • 1+11486.775401+1428.86219

    库存:13