1000 Eaton Boulevard
Cleveland, OH 44122
United States
120V 1000VA 500W A/V Digital Line-Interactive
UPS with LCD Status Screen, Tel/DSL/Coax
Protection
MODEL NUMBER: HT1000UPS
Highlights
●
Automatic voltage regulation
protects sensitive A/V
components from damaging
power fluctuations
●
Reliable battery support
preserves settings and
recordings through blackouts
●
EMI/RFI line noise filtering
improves component
performance (fuller
audio/sharper video)
●
8 widely spaced AC outlets (4
UPS/surge, 4 surge-only); USB
port and FREE PowerAlert
Software (Web download)
●
2-line 2.2 GHz
cable/satellite/antenna coaxial
surge protection plus single-line
tel/DSL surge protection
Package Includes
Description
●
HT1000UPS Audio/Video Digital
UPS System
●
1 phone and 2 gold coaxial
cables
●
Owner's manual with warranty
information
Tripp Lite's HT1000UPS Line-Interactive Digital UPS System offers voltage regulation, surge suppression
and long-lasting battery support for personal computers, home entertainment systems and media centers.
Internal UPS circuits support entry-level PCs for up to 60 minutes or individual VCR/DVR component for
as long as 3 hours during power failures. Prevents data loss, viewing interruptions, lost recordings and
loss of component programming. Automatic Voltage Regulation (AVR) circuits regulate brownouts as low
as 89 volts back to usable levels without consuming battery power. EMI/RFI line noise filtering improves
component performance, assuring fuller audio and sharper video. Includes 4 battery-supported outlets,
plus 4 surge suppression-only outlets for items not requiring battery support. USB port enables optional
unattended system shutdown without data loss in the case of extended power failure. PowerAlert
Software available via free download from www.tripplite.eaton.com. HID-compliant USB port also enables
integration with built-in power management and auto-shutdown features of Windows and Mac OS X. Builtin single-line RJ-11 phone jacks provide surge protection for a modem, satellite receiver or other
peripherals with a standard dialup/DSL phone connection. Two sets of 2.2 GHz coaxial jacks protect
against surges entering on CATV, satellite or broadcast antenna connections. Built-in audible alarm and
large LCD front panel voltage display indicates line power status, battery power status, battery low/replace
status and voltage boost operation. 1000VA/500W power-handling ability supports media center PCs,
home entertainment systems and audio/video components including flat-panel TVs, VCR/DVD players
and PVRs (TiVo®). Offers 3 min. battery runtime with a full load of 1000VA/500W and 11 min. with a half
load of 500VA/250W. $100,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only).
Features
●
LCD status screen indicates input voltage, battery capacity and a variety of operating conditions.
Display is rotatable for easy viewing wwith UPS placed vertically or horizontally
●
Offers automatic voltage regulation, surge suppression and long-lasting battery support during
blackouts
1/5
1000 Eaton Boulevard
Cleveland, OH 44122
United States
●
Supports entry-level PCs up to 60 min. or single VCR/DVR components for up to 3 hours during
blackouts
●
Regulates brownouts as low as 89V back to usable levels without using battery power
●
4 UPS battery-supported outlets plus 4 additional surge suppression-only outlets
●
USB port enables unattended shutdown in the case of extended power failure
●
HID-compliant USB port enables integration with built-in power management and auto-shutdown
features of Windows and Mac OS X
●
PowerAlert Software available via free download from tripplite.eaton.com
●
Single-line phone suppression protects standard dialup/DSL phone connection
●
2-line 2.2 GHz coaxial surge protection for cable, satellite and antenna connections
●
EMI/RFI line noise filtering improves component performance, assuring fuller audio and sharper video
●
1000VA/500W power handling ability supports a variety of sensitive computer, home theater and other
equipment
●
3 min. full load runtime (1000VA/500W), 11 min. half load runtime (500VA/250W)
●
Cabinet adapts to tower format or rackmount shelf format; 2U rackmount installation requires optional
shelf, available separately
●
Supports battery replacement via built-in access panel
●
$100,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Specifications
OVERVIEW
UPC Code
037332125262
UPS Type
Line-Interactive
INPUT
Input Phase
Single-Phase
Rated input current (Maximum Load)
12A
Nominal Input Voltage(s) Supported
120V AC
UPS Input Connection Type
5-15P
UPS Input Cord Length (ft.)
6
UPS Input Cord Length (m)
1.8
Recommended Electrical Service
15A 120V
OUTPUT
Output Capacity (VA)
1000
Output Capacity (Watts)
500
Frequency Compatibility
60 Hz
Output Voltage Regulation (Battery
Mode)
115V (+/- 5%)
UPS Output Receptacles (Surge
Suppression Only)
4 UPS outlets, 4 surge-only outlets
2/5
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Output AC Waveform (AC Mode)
Sine wave
Output AC Waveform (Battery
Mode)
PWM sine wave
Nominal Output Voltage(s)
Supported
115V; 120V
Output Receptacles
(8) 5-15R
Individually Controllable Load Banks
Yes
BATTERY
Runtime Full Load (min.)
3 min. (500w)
Runtime Half Load (min.)
11 min. (250w)
Expandable Runtime
No
DC System Voltage (VDC)
12
Battery Recharge Rate (Included
Batteries)
Less than 20 hours from 10% to 90%
Battery Access
Supports battery replacement via built-in access panel
VOLTAGE REGULATION
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89
Undervoltage Correction
Input voltages between 89 and 104 are boosted by 14%
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display
Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace
battery status; LCD screen rotates for rack/tower viewing
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status
Audible Alarm
Audible alarm indicates power-failure, low-battery and overload status; alarm can be disabled using PowerAlert
software
LED Indicators
Front panel LCD display
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
480
UPS AC Suppression Response
Time
Instantaneous
UPS Dataline Suppression
1 line TEL/DSL (1 in / 1 out); Coax jacks (2 sets)
UPS Dataline Suppression Details
HD-compatible 2.2GHz coaxial protection
EMI / RFI AC Noise Suppression
Yes
PHYSICAL
Primary Form Factor
Tower
3/5
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Installation Form Factors Supported
with Included Accessories
Tower
Primary UPS Depth (mm)
165
Primary UPS Height (mm)
305
Primary UPS Width (mm)
89
Shipping Dimensions (hwd / in.)
10.30 x 4.70 x 15.80
Shipping Dimensions (hwd / cm)
26.16 x 11.94 x 40.13
Shipping Weight (lbs.)
16.60
Shipping Weight (kg)
7.53
UPS Housing Material
ABS
UPS Power Module Dimensions
(hwd, cm)
30.48 x 8.89 x 16.51
UPS Power Module Dimensions
(hwd, in.)
12 x 3.5 x 6.5
UPS Power Module Weight (kg)
7.03
UPS Power Module Weight (lbs.)
15.5
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
52.6
Battery Mode BTU / Hr. (Full Load)
536.8
AC Mode Efficiency Rating (100%
Load)
97%
COMMUNICATIONS
PowerAlert Software
Free download from https://tripplite.eaton.com/products/power-alert
Communications Cable
USB cable included
WatchDog Compatibility
Supports Watchdog application, OS and hard-reboot restart options for remote applications
Network UPS Tools (NUT)
Compatibility
NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at
https://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite
Communications Interface
USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time
2-4 milliseconds
Low Voltage Transfer to Battery
Power (Setpoint)
89
High Voltage Transfer to Battery
Power (Setpoint)
139
4/5
1000 Eaton Boulevard
Cleveland, OH 44122
United States
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
Green Energy-Saving Features
Greater than 95% efficiency - GREEN UPS
WARRANTY & SUPPORT
Product Warranty Period
(Worldwide)
2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$100,000 Ultimate Lifetime
Insurance
© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark. All other trademarks
are the property of their respective owners.
5/5