0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SMART2200SLTAA

SMART2200SLTAA

  • 厂商:

    TRIPPLITE

  • 封装:

    -

  • 描述:

    UPS SMART TOWER AVR

  • 数据手册
  • 价格&库存
SMART2200SLTAA 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States TAA-Compliant SmartPro 120V 2.2kVA 1.6kW Line-Interactive Sine Wave UPS, Tower, Network Card Options, USB, DB9 Highlights ● Federal Trade Agreements Act / TAA Compliant for GSA Schedule purchases ● 2.2kVA / 2200VA line interactive tower UPS; Sine wave output ● 120V nominal output during brownouts to 83 and overvoltages to 145V ● USB, RS232, EPO and slot for optional Network Management Card ● Front panel status LEDs with detailed load and battery capacity display ● NEMA 5-20P input; 6 NEMA 515/20R & 1 L5-20R outlets MODEL NUMBER: SMART2200SLTAA Package Includes Description The SMART2200SLTAA is compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases. 2200VA line-interactive tower UPS system for server, networking and telecommunications equipment. Upright tower form factor. Offers sine wave 120V nominal output in both AC and battery modes. Switches to battery-derived AC output during power failures and extreme voltage variations. Lineinteractive automatic voltage regulation (AVR) provides voltage boost/cut during brownouts/overvoltages to maintain regulated 120V nominal output over an input voltage range of 83-145V. Includes NEMA 5-20P input plug and 7 UPS-supported (6 x 5-15/20R & 1 L5-20R) output receptacles. Network-grade AC surge and noise suppression. Network management interfaces support simultaneous communications via USB port, DB9 serial port and slot for Network Management Card option. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all three network interfaces. PowerAlert power management software is available via free download). Three-stage metered current monitoring and battery charge status LEDs. Utility power and voltage regulation, and battery warning LEDs. Audible alarm. Self-test. Field-replaceable, hot-swappable internal batteries. Attractive all-black color scheme. $250,000 connected equipment insur; (U.S., Canada, and Puerto Rico only). Features ● Compliant with the Federal Trade Agreements Act (TAA) for GSA Schedule purchases ● SmartPro line-interactive UPS system is ideal for voice, data, medical and industrial networking applications ● Line-interactive voltage regulation maintains selectable 120V nominal output during brownouts as low as 83V and overvoltages to 145V ● Enables continuous operation through blackouts, voltage fluctuations and surges ● Line-interactive automatic voltage regulation (AVR) provides 12% and 24% voltage boost during 1/5 ● SMART2200SLTAA TAA Compliant UPS System ● USB and DB9 Serial cabling ● User manual 1000 Eaton Boulevard Cleveland, OH 44122 United States brownouts and a 12% voltage cut during overvoltages ● Standard internal battery set offers 13 min. runtime at half load (800W) and 5 min. at full load (1600W) ● Space-saving upright tower format ● Network interfaces support simultaneous communications via built-in USB port, DB9 serial port and slot for Network Management Card option; Compatible with Tripp Lite UPS management card options WEBCARDLX and SNMPWEBCARD ● HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X ● USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert software, available via FREE download from tripplite.eaton.com/products/power-alert ● NEMA 5-20P input plug/6 x NEMA 5-15R and 1 x NEMA L5-20R output receptacles ● Front panel LEDs provide current monitoring, voltage regulation, battery charge level, and battery warning information ● UPS ships fully assembled in full compliance with DOT regulations; no time-consuming connection of internal batteries by user required ● $250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only) Specifications OVERVIEW UPC Code 037332152794 UPS Type Line-Interactive INPUT Input Phase Single-Phase Rated input current (Maximum Load) 14.8A Nominal Input Voltage(s) Supported 120V AC UPS Input Connection Type 5-20P Input Circuit Breakers 20A UPS Input Cord Length (ft.) 10 UPS Input Cord Length (m) 3.1 Recommended Electrical Service 20A 120V OUTPUT Output Capacity (VA) 2200 Output Capacity (kVA) 2.2 Output Capacity (Watts) 1600 Output Capacity (kW) 1.6 Power Factor 0.73 Nominal Voltage Details 120v nominal output in battery mode Frequency Compatibility 60 Hz 2/5 1000 Eaton Boulevard Cleveland, OH 44122 United States Output Voltage Regulation (Line Mode) -18% / +8% Output Voltage Regulation (Battery Mode) +/- 5% Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) Pure Sine wave Nominal Output Voltage(s) Supported 110V; 115V; 120V Output Receptacles (6) 5-15/20R; (1) L5-20R Individually Controllable Load Banks No BATTERY Runtime Full Load (min.) 5 min. (1600w) Runtime Half Load (min.) 13 min. (800w) Expandable Runtime No DC System Voltage (VDC) 48 Battery Recharge Rate (Included Batteries) Less than 4.5 hours from 10% to 90% Battery Access Battery access door Internal UPS Replacement Battery Cartridge  RBC54  Battery Replacement Description Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 83V to overvoltages to 145V Overvoltage Correction Input voltages between 127 and 145 are reduced by 12% Undervoltage Correction Input voltages between 96 and 108V are boosted by 12% Severe Undervoltage Correction Input voltages between 83 and 95V are boosted by 24% USER INTERFACE, ALERTS & CONTROLS Switches 2 Switches control off/on power status and alarm-cancel/self-test operation Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch Audible Alarm Audible alarm indicates power failure and overload conditions LED Indicators 9 LEDs indicate line power, battery power, AVR, overload and replace battery status - with a 3-LED level meter for load and battery charge level SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 570 UPS AC Suppression Response Time Instantaneous 3/5 1000 Eaton Boulevard Cleveland, OH 44122 United States EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Tower Cooling Method Fan Installation Form Factors Supported with Included Accessories Tower Primary UPS Depth (mm) 318 Primary UPS Height (mm) 267 Primary UPS Width (mm) 226 Shipping Dimensions (hwd / in.) 14.50 x 13.75 x 18.00 Shipping Dimensions (hwd / cm) 36.83 x 34.92 x 45.72 Shipping Weight (lbs.) 60.00 Shipping Weight (kg) 27.22 UPS Housing Material Steel UPS Power Module Dimensions (hwd, cm) 26.67 x 22.61 x 31.75 UPS Power Module Dimensions (hwd, in.) 10.5 x 8.9 x 12.5 UPS Power Module Weight (kg) 25.85 UPS Power Module Weight (lbs.) 57 ENVIRONMENTAL Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius Relative Humidity 5 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 287 Battery Mode BTU / Hr. (Full Load) 889 AC Mode Efficiency Rating (100% Load) 95% Audible Noise Audible Noise < 50 dBA at Front Side 1 Meter COMMUNICATIONS Network Management Cards SNMPWEBCARD;  WEBCARDLX  Network Monitoring Port Description Supports detailed monitoring of UPS and site power conditions PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at https://tripplite.eaton.com/products/power-alert Communications Cable USB and DB9 cabling included 4/5 1000 Eaton Boulevard Cleveland, OH 44122 United States WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications Communications Interface USB; DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface LINE / BATTERY TRANSFER Transfer Time 2-4 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 83 High Voltage Transfer to Battery Power (Setpoint) 145 FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Hot swappable batteries Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS WARRANTY & SUPPORT Product Warranty Period (Worldwide) 2-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance  © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 5/5
SMART2200SLTAA 价格&库存

很抱歉,暂时无法提供与“SMART2200SLTAA”相匹配的价格&库存,您可以联系我们找货

免费人工找货