1000 Eaton Boulevard
Cleveland, OH 44122
United States
SmartPro 120V 3kVA 2.88kW Line-Interactive
Sine Wave UPS, Hot-Swap, 2U, Extended Run,
Network Card Options, USB, DB9
Highlights
●
3kVA / 3000VA / 2880W line
interactive 2U rack/tower UPS,
Sine Wave
●
100/120/127V output, Corrects
brownouts and overvoltages 90
to 146V
●
0.96 Power Factor, Front panel
status LEDs
●
Hot-swappable internal UPS
power module
●
Extended runtime options up to
2880W
●
4 post compatible mounting
●
95% line-mode efficiency, 2
switched load banks
●
USB, RS232, EPO and slot for
Network Management Card
options
●
120V NEMA L5-30P input, 6
NEMA 5-15/20R & 1 L5-30R
outlets
●
This product is ENERGY STAR
qualified for its ability to save
customers money while helping
to protect the environment
MODEL NUMBER: SMART3000RMOD2U
Description
3000VA / 3kVA 120V modular line interactive 2U rack / tower UPS for networks offers complete networkgrade power protection with full support for hot-replacement of separate internal battery and electronics
Package Includes
●
UPS chassis pre-loaded with
hot-swappable UPS electronics
module and internal battery
module
cut automatic voltage regulation (AVR) provides regulated 110/120/127V nominal output during brownouts
●
USB, DB9 and EPO cabling
and overvoltages. Includes NEMA L5-30P input plug and 7 UPS-supported output receptacles (6 x 5-15R,
●
4 post rackmount installation
accessories
●
Owner's manual
modules. High .96 power factor supports loads up to 2880 watts. High efficiency rating of 95% reduces
electrical operating cost and BTU emissions. Offers selectable 110/120/127V 50/60Hz operation.
Maintains battery derived sine wave AC output during power failures. Line-interactive dual-boost, single
1 x L5-30R). Includes two individually controllable load banks, for advanced remote-reboot and loadshedding applications. Network-grade AC surge and noise suppression. Network management interfaces
support simultaneous communications via USB, DB9 serial and slot for Network Management Card
option. HID-compliant USB interface enables integration with built-in power management and auto
shutdown features of Windows and Mac OS X. Supports detailed monitoring of equipment load levels,
self-test data and utility power conditions via all three network interfaces at once. Advanced LED
indicators offer 5-stage metering of UPS load and battery charge levels, plus single-LED status indicators
for utility power, voltage regulation, on-battery, overload, replace battery and site wiring fault conditions.
Audible alarms provide notification of on-battery, low-battery and overload conditions. PowerAlert UPS
monitoring software is available for free download. Internal batteries offer runtime of 11 minutes half load
(1440 watts) and 4 minutes at full load (2880 watts). Runtime is expandable with optional BP72V15-2U
(limit 1), BP72V28RT-3U (limit 4) and BP72V18-2US (limit 2) external battery packs. Supports installation
in 4 post racks with included accessories. 2 post rackmount, wallmount and tower stand accessories sold
separate.
Features
●
3000VA / 3kVA 120V modular line interactive 2U rack / tower UPS for networks
1/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
●
Hot-swappable power module and internal battery packs enables full UPS maintenance with zerodowntime
●
High power factor of .96 offers support for loads to 2880 watts
●
High efficiency line power operation of 95% reduces UPS electrical operating cost and BTU emissions
●
Supports selectable 110, 120 and 127V nominal voltage operation at 50/60 Hz
●
Sine wave AC output in AC and battery modes
●
Line-interactive UPS with Automatic Voltage Regulation (AVR)
●
L5-30P input plug connects to 120V 30A utility receptacle
●
Includes 7 UPS supported outlets (6 5-15R and 1 L5-30R)
●
L5-30R outlet is ideal for the connection of a 120V 30A PDU to distribute the full UPS capacity to rack
equipment
●
5-15R outlets are arranged in two separately breakered, individually controllable loading banks to
support remote reboot or automated load shedding of less critical items (bank 1 has 2 outlets, bank 2
has 4 outlets).
●
Network-grade 800 joule AC surge suppression
●
Compatible with Tripp Lite UPS management card options WEBCARDLX, SNMPWEBCARD and
RELAYIOCARD
●
USB, DB9 serial and card-slot accessory are all available for simultaneous use in advanced network
configurations
●
HID compliant USB interface enables integration with built-in power management and auto shutdown
features of Windows and Mac OS X
●
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite's PowerAlert
software, available via FREE download from tripplite.eaton.com/products/power-alert
●
Advanced LED indicators offer 5-stage metering of UPS load and battery charge levels, plus single-LED
status indicators for utility power, voltage regulation, on-battery, overload, replace battery and site wiring
fault conditions.
●
Audible alarms provide notification of on-battery, low-battery and overload conditions.
●
Internal batteries offer runtime of 11 minutes half load (1440 watts) and 4 minutes at full load (2880
watts).
●
Runtime is expandable with optional BP72V15-2U (limit 1), BP72V28RT-3U (limit 4) and BP72V18-2US
(limit 2) external battery packs
●
Some external battery configurations require the use of Tripp Lite's External Battery Configuration
Software (see manual)
●
Intelligent battery management system extends battery life
●
Supports 4 post rackmount installation with included accessories; add 2POSTRMKITWM for 2 post and
wallmount applications; add 2-9USTAND accessory for upright tower support
●
This product is ENERGY STAR qualified for its ability to save customers money while helping to protect
the environment
Specifications
OVERVIEW
UPC Code
037332140234
UPS Type
Line-Interactive
INPUT
Input Phase
Single-Phase
2/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Rated input current (Maximum Load)
24A
Nominal Input Voltage(s) Supported
110V AC; 120V AC; 127V AC
UPS Input Connection Type
L5-30P
UPS Input Cord Length (ft.)
10
UPS Input Cord Length (m)
3.1
Recommended Electrical Service
30A 120V
Input Cord Length (ft.)
10
Input Cord Length (m)
3.05
OUTPUT
Output Capacity (VA)
3000
Output Capacity (kVA)
3
Output Capacity (Watts)
2880
Output Capacity (kW)
2.88
Output Capacity Details
2400W max capacity with external battery packs connected
Power Factor
0.96
Nominal Voltage Details
120V default
Frequency Compatibility
50 / 60 Hz
Frequency Compatibility Details
Automatic frequency selection
Output Voltage Regulation (Line
Mode)
120V: -7% +9%, 110V: -8% + 11%, 127V: -9% +9%
Output Voltage Regulation (Battery
Mode)
+/-5%
Load Management Receptacles
Two switchable load banks - bank one consists of 2 5-15R outlets, bank 2 consists of 4 5-15R outlets
Output Circuit Breakers
15A (x2) - breaker 1 covers 2 5-15R outlets, breaker 2 covers 4 5-15R outlets, L5-30R outlet is unbreakered
Output AC Waveform (AC Mode)
Pure Sine wave
Output AC Waveform (Battery
Mode)
Pure Sine wave
Nominal Output Voltage(s)
Supported
110V; 120V; 127V
Output Receptacles
(6) 5-15R; (1) L5-30R
Individually Controllable Load Banks
Yes
BATTERY
Runtime Full Load (min.)
4 min. (2880w)
Runtime Half Load (min.)
11 min. (1440w)
Expandable Runtime
Yes
3/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
External Battery Pack Compatibility
BP72V15-2U (limit 1); BP72V28RT-3U (multi-pack compatible); BP72V18-2US (multi-pack compatible)
DC System Voltage (VDC)
72
Battery Recharge Rate (Included
Batteries)
Less than 4 hours to 90% (typical, full load discharge)
Battery Access
Front panel battery access door
Internal UPS Replacement Battery
Cartridge
RBC96-RMOD2U
Battery Replacement Description
Hot-swappable, replaceable batteries
VOLTAGE REGULATION
Voltage Regulation Description
Automatic voltage regulation (AVR) maintains line power operation with an input voltage range of 90 to 146
Overvoltage Correction
Input voltages between 132 and 146 are reduced by 12%
Undervoltage Correction
Input voltages between 101 and 110 are boosted by 15%
Severe Undervoltage Correction
Input voltages between 90 and 100 are boosted by 30%
USER INTERFACE, ALERTS & CONTROLS
Switches
2 Switches control off/on power status and alarm-cancel/self-test operation
Alarm Cancel Operation
Power-fail alarm can be silenced by pressing the on/test/mute switch
Audible Alarm
Audible alarm indicates on battery, low battery and overload warnings
LED Indicators
14 LEDs indicate line power, power fail, avr, fault, overload, replace battery and site wiring fault conditions; includes
5 LED load and battery charge meter
Site Wiring Fault Indication
Includes site wiring fault LED
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating
800
EMI / RFI AC Noise Suppression
Yes
AC Suppression Joule Rating
800
AC Suppression Response Time
Instantaneous
PHYSICAL
Primary Form Factor
Rackmount
Rack Height
2U
Cooling Method
Fan
Included Mounting Accessory
Description
4 post rackmount installation accessories included
4/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Installation Form Factors Supported
with Optional Accessories
2 post rackmount ( 2POSTRMKITWM ); Wallmount
( 2POSTRMKITWM ); Tower ( 29USTAND )
Minimum Required Rack Depth (cm)
88.90
Minimum Required Rack Depth
(inches)
35
Primary UPS Depth (mm)
610
Primary UPS Height (mm)
89
Primary UPS Width (mm)
445
Shipping Dimensions (hwd / in.)
9.20 x 23.60 x 39.00
Shipping Dimensions (hwd / cm)
23.37 x 59.94 x 99.06
Shipping Weight (lbs.)
111.90
Shipping Weight (kg)
50.76
UPS Housing Material
Steel
UPS Power Module Dimensions
(hwd, cm)
8.89 x 44.45 x 60.96
UPS Power Module Dimensions
(hwd, in.)
3.5 x 17.5 x 24
UPS Power Module Weight (kg)
39.46
UPS Power Module Weight (lbs.)
87
ENVIRONMENTAL
Operating Temperature Range
+32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range
+5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity
0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load)
518
Battery Mode BTU / Hr. (Full Load)
1601
AC Mode Efficiency Rating (100%
Load)
95%
COMMUNICATIONS
Network Management Cards
SNMPWEBCARD; WEBCARDLX ; RELAYIOCARD
Network Monitoring Port Description
Supports detailed monitoring of UPS and site power conditions
PowerAlert Software
For local monitoring via the UPS’s built-in communication ports, download PowerAlert software at
https://tripplite.eaton.com/products/power-alert
Communications Cable
USB, DB9 and EPO cabling included
Communications Interface
DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
5/6
1000 Eaton Boulevard
Cleveland, OH 44122
United States
LINE / BATTERY TRANSFER
Transfer Time
10 ms (line to battery) / 4 ms (battery to line)
Low Voltage Transfer to Battery
Power (Setpoint)
90
High Voltage Transfer to Battery
Power (Setpoint)
146
FEATURES & SPECIFICATIONS
Cold Start (Startup in Battery Mode
During a Power Failure)
Cold-start operation supported
High Availability UPS Features
Hot swappable batteries; Hot swappable UPS power module
WARRANTY & SUPPORT
Product Warranty Period
(Worldwide)
2-year limited warranty
Connected Equipment Insurance
(U.S., Canada & Puerto Rico)
$250,000 Ultimate Lifetime
Insurance
© 2023 Eaton. All Rights Reserved.
Eaton is a registered trademark. All other trademarks
are the property of their respective owners.
6/6