0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PDUMNH32HVAT

PDUMNH32HVAT

  • 厂商:

    TRIPPLITE

  • 封装:

    -

  • 描述:

    7.4KW SINGLE-PHASE 230V ATS/MONI

  • 数据手册
  • 价格&库存
PDUMNH32HVAT 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch PDU, Two 32A IEC309 32A Blue Inputs, 1 IEC309 32A Outlet, 1U Highlights ● Two IEC 309 32A Blue (2P+E) inputs, each with 10-ft. (3.05 m) input cord ● One IEC 309 32A Blue (2P+E) output receptacle for connecting device or multi-outlet PDU ● ATS / Automatic Transfer Switching within 1-5 ms ● Pre-installed WEBCARDLX with latest version of PADM20 for enhanced remote management ● Digital display with LEDs for real-time status monitoring MODEL NUMBER: PDUMNH32HVAT Package Includes High-capacity 7.7kW PDU with ATS provides remote power monitoring and enables redundant power for non-redundant hardware. Digital display and Ethernet interface allow site power status monitoring for primary and secondary inputs, plus load level monitoring to prevent overload conditions. Description The PDUMNH32HVAT 7.7kW Single-Phase 200-240V Monitored Automatic Transfer Switch / ATS PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIAstandard 19-inch racks and has one IEC 309 32A Blue outlet for connecting a single device or an additional 230V multi-outlet PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV. Dual 10-ft. (3.05 m) input cords, each with IEC 309 32A Blue input plug, connect to any two separate primary and secondary input power sources, including out-of-phase input sources. The PDU constantly evaluates the power quality of both inputs. To ensure connected equipment remains powered, dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable. Built-in LX Platform network management interface allows remote access to the PDU for power monitoring, configuration, control and to receive user-configurable notifications. The Java-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSH. Provides real-time load/current data with billing-grade accuracy (±1 percent). It supports 10/100 Mbps auto-sensing for optimum communication with an Ethernet network. Optional EnviroSense2 modules (sold separate) provide a variety of environmental monitoring capabilities. Protocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP. Features Primary and Secondary Inputs for Power RedundancyEnables redundant power configurations for network devices with a single input cord or other non-redundant power supply configurationTwo IEC 309 32A Blue (2P+E) inputs, each with 10-ft. (3.05 m) cord, connect to separate primary and secondary input power sourcesAny two input power sources are supported for primary and secondary inputs, including out-of-phase power sources Built-In IEC 309 32A Blue OutletPower a single 32A plug-in device or multiple network devices through a connected 32A 200-240V multi-outlet PDU, such as Tripp Lite's PDUMV32HV metered PDU input (sold separately) Automatic Transfer SwitchingDynamic solid-state (TRIAC) automatic transfer switchingSwitches to 1/4 ● PDUMNH32HVAT 7.7kW Single-Phase 200-240V ATS/Monitored PDU ● Rack-mounting brackets ● PDU4PKIT rear support rail kit ● Owner’s manual 1000 Eaton Boulevard Cleveland, OH 44122 United States secondary power source if primary source fails or becomes unstable1-5 ms transfer time ensures uninterrupted operation of connected equipmentBuilt-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source Touchscreen LCDReports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor Advanced Network MonitoringPre-installed WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilitiesPADM20 and PowerAlert Element Manager (PAEM) form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations Broad Communications CompatibilityJava-free LX Platform HTML5-based network interface enables full remote access for PDU status monitoring and email notifications via secure web browser, SNMP, telnet or SSHSupports 10/100 Mbps auto-sensing for optimum communication with an Ethernet networkProtocols supported include HTTP, HTTPS, SMTP, SNMPv1, SNMPv2, SNMPv3, telnet, SSH, FTP, DHCP and NTP.10/100 Mbps auto-sensing for communication with 10/100 Base-T networks Mounts Horizontally in 1U of Rack SpaceCompatible with EIA-standard 19 in. 4-post racks and rack enclosuresIncluded PDU4PKIT rail kit adds rear rack-mounting support Specifications OVERVIEW UPC Code 037332187871 PDU Type Monitored; Auto-Transfer Switch INPUT PDU Input Voltage 200; 208; 220; 230; 240 Recommended Electrical Service Two single-phase 32A 200-240V circuits Maximum Input Amps 32 PDU Plug Type (2) IEC-309 32A BLUE (2P+E) Input Phase Single-Phase Input Cord Details Set of two inputs connect to separate PRIMARY and SECONDARY power sources Input Cord Length (ft.) 10 Input Cord Length (m) 3.05 OUTPUT Output Capacity Details 7.7kW (240V), 7.4kW (230V), 7.0kW (220V), 6.7kW (208V), 6.4kW (200V) total capacity; 32A maximum Frequency Compatibility 50 / 60 Hz Output Receptacle Details Output receptacle is on a 61cm / 24 inch cordset Output Receptacles IEC309 32A BLUE (2P+E) Output Nominal Voltage 200-240V USER INTERFACE, ALERTS & CONTROLS 2/4 1000 Eaton Boulevard Cleveland, OH 44122 United States Front Panel LCD Display Digital display reports input current in amps (Source A, Source B), output kilowatts (total), input voltage (Source A, Source B), input frequency (Source A, Source B) and output power factor Front Panel LEDs Front panel LEDs confirm amp (A) / kilowatt (kW) / voltage (V) / frequency (Hz) and power factor (PF) reporting information; Additional set of LEDs indicate Source A and Source B inputs for preferred, available and in-use status Switches ENTER and MODE switches toggle the digital display to display all reported information Current Measurement Accuracy (Amps) +/-1% Voltage Measurement Accuracy (Volts) +/-1% Power Measurement Accuracy (Watts) +/-1% SURGE / NOISE SUPPRESSION Automatic Shut-Off No PHYSICAL Material of Construction Metal Form Factors Supported 1U rackmount Included Mounting Accessory Description Included mounting rails compatible with rack depth settings from 57.9 to 91.5cm (22.8 to 36 inches) Minimum Required Rack Depth (cm) 44.45 Minimum Required Rack Depth (inches) 17.5 PDU Form Factor Horizontal (1U) Shipping Dimensions (hwd / in.) 7.20 x 21.30 x 22.50 Shipping Dimensions (hwd / cm) 18.29 x 54.10 x 57.15 Shipping Weight (lbs.) 21.60 Shipping Weight (kg) 9.80 Unit Dimensions (hwd / in.) 1.720 x 16.930 x 14.000 Unit Dimensions (hwd / cm) 4.4 x 43 x 35.6 Unit Weight (lbs.) 18.26 Unit Weight (kg) 8.28 ENVIRONMENTAL Operating Temperature Range 0C ~ 50C (32F ~ 122F) Storage Temperature Range -30°C to +60°C (-22°F to +140°F) Relative Humidity 5-95% non-condensing Operating Elevation (ft.) 0-10,000 Operating Elevation (m) 0-3000 3/4 1000 Eaton Boulevard Cleveland, OH 44122 United States COMMUNICATIONS PowerAlert Software LX Platform Interface: PowerAlert Device Manager Communications Cable Micro-USB- to-USB A configuration/console Access cable Network Monitoring Port RJ45 Network port, Micro-USB Configuration port, USB A port supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. SNMP Compatibility Pre-installed LX platform interface provides remote monitoring via Java-free HTML5 web interface, telnet, SSH and SNMP management systems Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet) FEATURES & SPECIFICATIONS High Availability PDU Features Auto-Transfer Switching STANDARDS & COMPLIANCE Product Certifications EN 60950-1 Product Compliance RoHS; CE (Europe); FCC Part 15 Class A (USA) WARRANTY & SUPPORT Product Warranty Period (Worldwide) 2-year limited warranty © 2022 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 4/4
PDUMNH32HVAT 价格&库存

很抱歉,暂时无法提供与“PDUMNH32HVAT”相匹配的价格&库存,您可以联系我们找货

免费人工找货