0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-50E1001-D-74

BXRC-50E1001-D-74

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO105000KSTARBOARD

  • 数据手册
  • 价格&库存
BXRC-50E1001-D-74 数据手册
Bridgelux Gen 7 Vero 10 Array ® ® Product Data Sheet DS90 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features • Efficacy of 167 lm/W typical • Lumen output performance ranges from 520 to 4,100 lumens • Broad range of CCT options from 2700K to 6500K • CRI options include minimum 65, 70, 80, and 90 • 2 and 3 SDCM color control for 2700K-4000K CCT • Reliable operation at up to 2X nominal drive current • Radial die pattern and improved lumen density Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Flexibility in design optimization • Enhanced ease of use and assembly • Thermally isolated solder pads • Solderless connectivity enables plug & play installation and field upgradability • On-board connector port • Improved inventory management and quality control • Top side part number markings • Vf bin code backside marking Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 19 Eye Safety 20 Absolute Maximum Ratings 21 Performance Curves 22 Typical Radiation Pattern 25 Typical Color Spectrum 26 Mechanical Dimensions 27 Color Binning Information 28 Packaging and Labeling 29 Design Resources 31 Precautions 31 Disclaimers 31 About Bridgelux 32 1 Product Feature Map Vero 10 is the smallest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Mounting holes Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 100 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 20 = 2,000K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 100x = 1000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 152 BXRC-20B1000-B-73 2000 65 270 1431 1259 34.8 9.4 BXRC-20B1000-D-73 2000 65 350 1386 1220 26.0 9.1 152 BXRC-27E1000-B-7x 2700 80 270 1458 1283 34.8 9.4 155 BXRC-27E1000-C-7x 2700 80 360 1944 1711 34.8 12.5 155 BXRC-27E1000-D-7x 2700 80 350 1412 1243 26.0 9.1 155 BXRC-27G10H0-B-7x 2700 90 270 1249 1099 34.8 9.4 133 BXRC-27G10H0-C-7x 2700 90 360 1665 1465 34.8 12.5 133 BXRC-27G10H0-D-7x 2700 90 350 1209 1064 26.0 9.1 133 BXRC-27G1000-B-7x 2700 90 270 1203 1059 34.8 9.4 128 BXRC-27G1000-C-7x 2700 90 360 1604 1412 34.8 12.5 128 BXRC-27G1000-D-7x 2700 90 350 1165 1025 26.0 9.1 128 BXRC-27H1000-B-7x 2700 97 270 1066 938 34.8 9.4 113 BXRC-27H1000-C-7x 2700 97 360 1422 1251 34.8 12.5 113 BXRC-27H1000-D-7x 2700 97 350 1033 909 26.0 9.1 113 BXRC-30C1001-B-74 3000 70 270 1622 1428 34.8 9.4 173 BXRC-30C1001-C-74 3000 70 360 2163 1904 34.8 12.5 173 BXRC-30C1001-D-74 3000 70 350 1571 1383 26.0 9.1 173 BXRC-30E1000-B-7x 3000 80 270 1549 1363 34.8 9.4 165 BXRC-30E1000-C-7x 3000 80 360 2066 1818 34.8 12.5 165 BXRC-30E1000-D-7x 3000 80 350 1501 1321 26.0 9.1 165 BXRC-30G10H0-B-7x 3000 90 270 1312 1155 34.8 9.4 140 BXRC-30G10H0-C-7x 3000 90 360 1750 1540 34.8 12.5 140 BXRC-30G10H0-D-7x 3000 90 350 1271 1119 26.0 9.1 140 BXRC-30G1000-B-7x 3000 90 270 1258 1107 34.8 9.4 134 134 BXRC-30G1000-C-7x 3000 90 360 1677 1476 34.8 12.5 BXRC-30G1000-D-7x 3000 90 350 1218 1072 26.0 9.1 134 BXRC-30G100C-B-73 3000 90 270 1212 1067 34.8 9.4 129 BXRC-30G100C-D-73 3000 90 350 1174 1033 26.0 9.1 129 BXRC-30H1000-B-7x 3000 97 270 1139 1003 34.8 9.4 121 BXRC-30H1000-C-7x 3000 97 360 1519 1337 34.8 12.5 121 BXRC-30H1000-D-7x 3000 97 350 1103 971 26.0 9.1 121 BXRC-30A1001-B-73 3000 93 270 1130 995 34.8 9.4 120 8,9 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI Nominal Drive Current3 (mA) 2 Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A1001-C-738,9 3000 93 360 1507 1326 34.8 12.5 120 BXRC-30A1001-D-738,9 3000 93 350 1095 963 26.0 9.1 120 BXRC-35E1000-B-7x 3500 80 270 1586 1396 34.8 9.4 169 BXRC-35E1000-C-7x 3500 80 360 2114 1861 34.8 12.5 169 BXRC-35E1000-D-7x 3500 80 350 1536 1352 26.0 9.1 169 BXRC-35G1000-B-7x 3500 90 270 1303 1147 34.8 9.4 139 BXRC-35G1000-C-7x 3500 90 360 1738 1529 34.8 12.5 139 BXRC-35G1000-D-7x 3500 90 350 1262 1111 26.0 9.1 139 BXRC-35A1001-B-738,9 3500 93 270 1203 1059 34.8 9.4 128 BXRC-35A1001-C-73 8,9 3500 93 360 1604 1412 34.8 12.5 128 BXRC-35A1001-D-738,9 3500 93 350 1165 1025 26.0 9.1 128 BXRC-40C1001-B-74 4000 70 270 1668 1468 34.8 9.4 178 178 BXRC-40C1001-C-74 4000 70 360 2224 1957 34.8 12.5 BXRC-40C1001-D-74 4000 70 350 1615 1422 26.0 9.1 178 BXRC-40E1000-B-7x 4000 80 270 1595 1404 34.8 9.4 170 BXRC-40E1000-C-7x 4000 80 360 2127 1871 34.8 12.5 170 BXRC-40E1000-D-7x 4000 80 350 1545 1359 26.0 9.1 170 BXRC-40G1000-B-7x 4000 90 270 1331 1171 34.8 9.4 142 BXRC-40G1000-C-7x 4000 90 360 1774 1561 34.8 12.5 142 BXRC-40G1000-D-7x 4000 90 350 1289 1134 26.0 9.1 142 BXRC-40H1000-B-7x 4000 97 270 1203 1059 34.8 9.4 128 128 BXRC-40H1000-C-7x 4000 97 360 1604 1412 34.8 12.5 BXRC-40H1000-D-7x 4000 97 350 1165 1025 26.0 9.1 128 BXRC-40A1001-B-738,9 4000 93 270 1303 1147 34.8 9.4 139 BXRC-40A1001-C-738,9 4000 93 360 1738 1529 34.8 12.5 139 BXRC-40A1001-D-738,9 4000 93 350 1262 1111 26.0 9.1 139 BXRC-50C1001-B-7x 5000 70 270 1677 1476 34.8 9.4 178 BXRC-50C1001-C-7x 5000 70 360 2236 1968 34.8 12.5 178 BXRC-50C1001-D-7x 5000 70 350 1624 1429 26.0 9.1 178 BXRC-50E1001-B-7x 5000 80 270 1613 1420 34.8 9.4 172 BXRC-50E1001-C-7x 5000 80 360 2151 1893 34.8 12.5 172 BXRC-50E1001-D-7x 5000 80 350 1562 1375 26.0 9.1 172 BXRC-50G1001-B-7x 5000 90 270 1394 1227 34.8 9.4 148 BXRC-50G1001-C-7x 5000 90 360 1859 1636 34.8 12.5 148 BXRC-50G1001-D-7x 5000 90 350 1351 1188 26.0 9.1 148 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI 2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C1001-B-7x 5700 70 270 1631 1436 34.8 9.4 174 BXRC-57C1001-C-7x 5700 70 360 2175 1914 34.8 12.5 174 BXRC-57C1001-D-7x 5700 70 350 1580 1390 26.0 9.1 174 BXRC-57E1001-B-7x 5700 80 270 1549 1363 34.8 9.4 165 BXRC-57E1001-C-7x 5700 80 360 2066 1818 34.8 12.5 165 BXRC-57E1001-D-7x 5700 80 350 1501 1321 26.0 9.1 165 BXRC-65C1001-B-7x 6500 70 270 1631 1436 34.8 9.4 174 BXRC-65C1001-C-7x 6500 70 360 2175 1914 34.8 12.5 174 BXRC-65C1001-D-7x 6500 70 350 1580 1390 26.0 9.1 174 BXRC-65E1001-B-7x 6500 80 270 1568 1380 34.8 9.4 167 BXRC-65E1001-C-7x 6500 80 360 2090 1839 34.8 12.5 167 BXRC-65E1001-D-7x 6500 80 350 1518 1336 26.0 9.1 167 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A1001-B-73 3000 80 93 270 1051 875 34.3 9.3 114 BXRC-30A1001-C-73 3000 80 93 360 1401 1167 34.3 12.3 114 BXRC-30A1001-D-73 3000 80 93 350 1018 848 25.5 8.9 114 BXRC-35A1001-B-73 3500 80 93 270 1119 1228 34.3 9.3 121 BXRC-35A1001-C-73 3500 80 93 360 1492 1637 34.3 12.3 121 BXRC-35A1001-D-73 3500 80 93 350 1084 1189 25.5 8.9 122 BXRC-40A1001-B-73 4000 80 93 270 1212 1009 34.3 9.3 131 BXRC-40A1001-C-73 4000 80 93 360 1616 1346 34.3 12.3 131 BXRC-40A1001-D-73 4000 80 93 350 1174 977 25.5 8.9 132 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-20B1000-B-73 2000 65 270 1288 1133 33.8 9.1 141 BXRC-20B1000-D-73 2000 65 350 1247 1098 25.3 8.9 141 BXRC-27E1000-B-7x 2700 80 270 1312 1155 33.8 9.1 144 BXRC-27E1000-C-7x 2700 80 360 1750 1540 33.8 12.2 144 BXRC-27E1000-D-7x 2700 80 350 1271 1119 25.3 8.9 144 BXRC-27G10H0-B-7x 2700 90 270 1124 989 33.8 9.1 123 BXRC-27G10H0-C-7x 2700 90 360 1498 1319 33.8 12.2 123 BXRC-27G10H0-D-7x 2700 90 350 1088 958 25.3 8.9 123 BXRC-27G1000-B-7x 2700 90 270 1083 953 33.8 9.1 119 BXRC-27G1000-C-7x 2700 90 360 1444 1270 33.8 12.2 119 BXRC-27G1000-D-7x 2700 90 350 1049 923 25.3 8.9 118 BXRC-27H1000-B-7x 2700 97 270 960 845 33.8 9.1 105 BXRC-27H1000-C-7x 2700 97 360 1280 1126 33.8 12.2 105 BXRC-27H1000-D-7x 2700 97 350 929 818 25.3 8.9 105 BXRC-30C1001-B-74 3000 70 270 1460 1285 33.8 9.1 160 BXRC-30C1001-C-74 3000 70 360 1947 1713 33.8 12.2 160 BXRC-30C1001-D-74 3000 70 350 1414 1244 25.3 8.9 160 BXRC-30E1000-B-7x 3000 80 270 1394 1227 33.8 9.1 153 BXRC-30E1000-C-7x 3000 80 360 1859 1636 33.8 12.2 153 BXRC-30E1000-D-7x 3000 80 350 1351 1188 25.3 8.9 153 BXRC-30G10H0-B-7x 3000 90 270 1181 1039 33.8 9.1 129 BXRC-30G10H0-C-7x 3000 90 360 1575 1386 33.8 12.2 129 BXRC-30G10H0-D-7x 3000 90 350 1144 1007 25.3 8.9 129 BXRC-30G1000-B-7x 3000 90 270 1132 996 33.8 9.1 124 BXRC-30G1000-C-7x 3000 90 360 1509 1328 33.8 12.2 124 BXRC-30G1000-D-7x 3000 90 350 1096 965 25.3 8.9 124 BXRC-30G100C-B-73 3000 90 270 1091 960 33.8 9.1 120 BXRC-30G100C-D-73 3000 90 350 1057 930 25.3 8.9 119 BXRC-30H1000-B-7x 3000 97 270 1025 902 33.8 9.1 112 BXRC-30H1000-C-7x 3000 97 360 1367 1203 33.8 12.2 112 BXRC-30H1000-D-7x 3000 97 350 993 874 25.3 8.9 112 BXRC-30A1001-B-737,8 3000 93 270 1017 895 33.8 9.1 111 BXRC-30A1001-C-737,8 3000 93 360 1356 1193 33.8 12.2 111 BXRC-30A1001-D-73 3000 93 350 985 867 25.3 8.9 111 3500 80 270 1427 1256 33.8 9.1 156 7,8 BXRC-35E1000-B-7x Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E1000-C-7x 3500 80 360 1903 1675 33.8 12.2 156 BXRC-35E1000-D-7x 3500 80 350 1382 1216 25.3 8.9 156 BXRC-35G1000-B-7x 3500 90 270 1173 1032 33.8 9.1 128 BXRC-35G1000-C-7x 3500 90 360 1564 1376 33.8 12.2 128 BXRC-35G1000-D-7x 3500 90 350 1136 1000 25.3 8.9 128 BXRC-35A1001-B-73 7,8 3500 93 270 1083 953 33.8 9.1 119 BXRC-35A1001-C-737,8 3500 93 360 1444 1270 33.8 12.2 119 BXRC-35A1001-D-737,8 3500 93 350 1049 923 25.3 8.9 118 BXRC-40C1001-B-74 4000 70 270 1501 1321 33.8 9.1 164 BXRC-40C1001-C-74 4000 70 360 2001 1761 33.8 12.2 164 BXRC-40C1001-D-74 4000 70 350 1454 1279 25.3 8.9 164 BXRC-40E1000-B-7x 4000 80 270 1435 1263 33.8 9.1 157 BXRC-40E1000-C-7x 4000 80 360 1914 1684 33.8 12.2 157 BXRC-40E1000-D-7x 4000 80 350 1390 1223 25.3 8.9 157 BXRC-40G1000-B-7x 4000 90 270 1198 1054 33.8 9.1 131 BXRC-40G1000-C-7x 4000 90 360 1597 1405 33.8 12.2 131 BXRC-40G1000-D-7x 4000 90 350 1160 1021 25.3 8.9 131 BXRC-40H1000-B-7x 4000 97 270 1083 953 33.8 9.1 119 BXRC-40H1000-C-7x 4000 97 360 1444 1270 33.8 12.2 119 BXRC-40H1000-D-7x 4000 97 350 1049 923 25.3 8.9 118 BXRC-40A1001-B-737,8 4000 93 270 1173 1032 33.8 9.1 128 128 BXRC-40A1001-C-737,8 4000 93 360 1564 1376 33.8 12.2 BXRC-40A1001-D-737,8 4000 93 350 1136 1000 25.3 8.9 128 BXRC-50C1001-B-7x 5000 70 270 1509 1328 33.8 9.1 165 BXRC-50C1001-C-7x 5000 70 360 2012 1771 33.8 12.2 165 BXRC-50C1001-D-7x 5000 70 350 1462 1286 25.3 8.9 165 BXRC-50E1001-B-7x 5000 80 270 1452 1278 33.8 9.1 159 BXRC-50E1001-C-7x 5000 80 360 1936 1704 33.8 12.2 159 BXRC-50E1001-D-7x 5000 80 350 1406 1237 25.3 8.9 159 BXRC-50G1001-B-7x 5000 90 270 1255 1104 33.8 9.1 137 BXRC-50G1001-C-7x 5000 90 360 1673 1473 33.8 12.2 137 BXRC-50G1001-D-7x 5000 90 350 1215 1070 25.3 8.9 137 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C1001-B-7x 5700 70 270 1468 1292 33.8 9.1 161 BXRC-57C1001-C-7x 5700 70 360 1958 1723 33.8 12.2 161 BXRC-57C1001-D-7x 5700 70 350 1422 1251 25.3 8.9 161 BXRC-57E1001-B-7x 5700 80 270 1394 1227 33.8 9.1 153 BXRC-57E1001-C-7x 5700 80 360 1859 1636 33.8 12.2 153 BXRC-57E1001-D-7x 5700 80 350 1351 1188 25.3 8.9 153 BXRC-65C1001-B-7x 6500 70 270 1468 1292 33.8 9.1 161 BXRC-65C1001-C-7x 6500 70 360 1958 1723 33.8 12.2 161 BXRC-65C1001-D-7x 6500 70 350 1422 1251 25.3 8.9 161 BXRC-65E1001-B-7x 6500 80 270 1411 1242 33.8 9.1 154 BXRC-65E1001-C-7x 6500 80 360 1881 1655 33.8 12.2 154 BXRC-65E1001-D-7x 6500 80 350 1366 1202 25.3 8.9 154 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-20B1001-B-73 65 BXRC-20B1001-D-73 65 BXRC-27E1000-B-7x 80 BXRC-27E1000-C-7x 80 BXRC-27E1000-D-7x 80 BXRC-27G10H0-B-7x 90 BXRC-27G10H0-C-7x 90 BXRC-27G10H0-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 762 1000 1431 2099 2689 740 971 1386 2040 2613 777 1019 1458 2139 2741 1034 1354 1944 2831 3617 754 989 1412 2079 2663 665 872 1249 1832 2347 885 1160 1665 2424 3097 646 847 1209 1780 2280 685 897 1288 1867 2380 673 873 1247 1759 2201 698 914 1312 1903 2426 922 1203 1750 2460 3096 686 889 1271 1793 2243 598 783 1124 1630 2077 790 1030 1498 2106 2651 587 762 1088 1535 1920 170 163 152 145 138 170 164 152 142 131 173 166 155 148 140 173 166 155 147 139 173 167 155 145 134 148 143 133 127 120 148 142 133 126 119 148 143 133 124 115 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G1000-B-7x 90 BXRC-27G1000-C-7x 90 BXRC-27G1000-D-7x 90 BXRC-27H1000-B-7x 97 BXRC-27H1000-C-7x 97 BXRC-27H1000-D-7x 97 BXRC-30C1001-B-74 70 BXRC-30C1001-C-74 70 BXRC-30C1001-D-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 641 841 1203 1765 2261 853 1117 1604 2336 2984 622 816 1165 1715 2197 568 745 1066 1564 2004 756 990 1422 2070 2645 551 723 1033 1520 1948 864 1134 1622 2380 3049 1150 1507 2163 3150 4023 839 1101 1571 2313 2963 576 754 1083 1570 2001 761 993 1444 2029 2554 566 734 1049 1479 1850 511 668 960 1392 1774 675 880 1280 1799 2264 501 650 929 1311 1640 777 1017 1460 2117 2699 1026 1338 1947 2736 3444 763 990 1414 1995 2495 143 137 128 122 116 143 137 128 121 115 143 138 128 119 110 127 122 113 108 103 126 121 113 108 102 126 122 113 106 98 193 185 173 165 156 192 185 173 164 155 192 186 173 161 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E1000-B-7x 80 BXRC-30E1000-C-7x 80 BXRC-30E1000-D-7x 80 BXRC-30G10H0-B-7x 90 BXRC-30G10H0-C-7x 90 BXRC-30G10H0-D-7x 90 BXRC-30G1000-B-7x 90 BXRC-30G1000-C-7x 90 BXRC-30G1000-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 826 1083 1549 2273 2912 1098 1439 2066 3008 3843 801 1051 1501 2209 2830 699 917 1312 1925 2467 930 1219 1750 2548 3255 679 890 1271 1871 2397 670 879 1258 1845 2364 892 1168 1677 2442 3119 650 853 1218 1793 2297 742 971 1394 2022 2577 980 1278 1859 2613 3289 729 945 1351 1905 2383 628 823 1181 1713 2183 830 1083 1575 2214 2786 617 801 1144 1614 2018 602 788 1132 1641 2092 796 1038 1509 2121 2670 591 767 1096 1546 1934 184 177 165 157 149 184 176 165 156 148 184 178 165 154 142 156 150 140 133 126 156 149 140 132 125 156 150 140 130 121 149 144 134 128 121 149 143 134 127 120 149 144 134 125 115 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G100C-B-73 90 BXRC-30G100C-D-73 90 BXRC-30H1000-B-7x 97 BXRC-30H1000-C-7x 97 BXRC-30H1000-D-7x 97 BXRC-30A1001-B-73 93 BXRC-30A1001-C-73 93 BXRC-30A1001-D-73 93 BXRC-35E1000-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 646 847 1212 1778 2278 627 822 1174 1728 2214 607 796 1139 1671 2141 808 1058 1519 2212 2825 589 773 1103 1624 2081 602 790 1130 1658 2124 801 1050 1507 2194 2803 584 767 1095 1611 2064 845 1108 1586 2327 2981 580 760 1091 1582 2016 570 739 1057 1490 1864 546 714 1025 1487 1895 721 940 1367 1922 2419 536 695 993 1401 1752 541 708 1017 1475 1880 715 932 1356 1906 2399 531 689 985 1390 1738 759 994 1427 2070 2638 144 138 129 123 117 144 139 129 120 111 135 130 121 116 110 135 130 121 115 109 135 131 121 113 105 134 129 120 115 109 134 129 120 114 108 134 130 120 112 104 188 181 169 161 153 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35E1000-C-7x 80 BXRC-35E1000-D-7x 80 BXRC-35G1000-B-7x 90 BXRC-35G1000-C-7x 90 BXRC-35G1000-D-7x 90 BXRC-35A1001-B-73 93 BXRC-35A1001-C-73 93 BXRC-35A1001-D-73 93 BXRC-40C1001-B-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1124 1473 2114 3079 3933 820 1076 1536 2261 2896 695 911 1303 1912 2450 924 1210 1738 2530 3232 674 884 1262 1858 2380 641 841 1203 1765 2261 853 1117 1604 2336 2984 622 816 1165 1715 2197 889 1165 1668 2447 3135 1003 1308 1903 2675 3367 746 967 1382 1950 2439 624 817 1173 1701 2168 824 1075 1564 2198 2767 613 795 1136 1602 2004 576 754 1083 1570 2001 761 993 1444 2029 2554 566 734 1049 1479 1850 799 1045 1501 2177 2775 188 180 169 160 151 188 182 169 157 146 155 149 139 132 126 155 148 139 131 124 155 149 139 129 120 143 137 128 122 116 143 137 128 121 115 143 138 128 119 110 198 190 178 170 161 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C1001-C-74 70 BXRC-40C1001-D-74 70 BXRC-40E1000-B-7x 80 BXRC-40E1000-C-7x 80 BXRC-40E1000-D-7x 80 BXRC-40G1000-B-7x 90 BXRC-40G1000-C-7x 90 BXRC-40G1000-D-7x 90 BXRC-40H1000-B-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1182 1549 2224 3238 4136 862 1131 1615 2378 3046 850 1114 1595 2340 2998 1131 1481 2127 3097 3956 825 1082 1545 2274 2913 709 930 1331 1952 2501 943 1236 1774 2584 3300 688 903 1289 1897 2430 641 841 1203 1765 2261 1055 1376 2001 2813 3541 784 1017 1454 2051 2565 764 1000 1435 2082 2653 1009 1316 1914 2690 3386 750 973 1390 1961 2453 637 834 1198 1737 2214 842 1098 1597 2244 2825 626 812 1160 1636 2047 576 754 1083 1570 2001 198 190 178 168 159 198 191 178 165 153 190 182 170 162 154 189 181 170 161 152 189 183 170 158 146 158 152 142 135 128 158 151 142 134 127 158 153 142 132 122 143 137 128 122 116 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40H1000-C-7x 97 BXRC-40H1000-D-7x 97 BXRC-40A1001-B-73 93 BXRC-40A1001-C-73 93 BXRC-40A1001-D-73 93 BXRC-50C1001-B-7x 70 BXRC-50C1001-C-7x 70 BXRC-50C1001-D-7x 70 BXRC-50E1001-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 853 1117 1604 2336 2984 622 816 1165 1715 2197 695 911 1303 1912 2450 924 1210 1738 2530 3232 674 884 1262 1858 2380 894 1172 1677 2460 3152 1189 1557 2236 3256 4159 867 1138 1624 2391 3063 860 1127 1613 2367 3032 761 993 1444 2029 2554 566 734 1049 1479 1850 624 817 1173 1701 2168 824 1075 1564 2198 2767 613 795 1136 1602 2004 803 1051 1509 2189 2790 1061 1384 2012 2828 3560 789 1023 1462 2062 2579 773 1011 1452 2105 2684 143 137 128 121 115 143 138 128 119 110 155 149 139 132 126 155 148 139 131 124 155 149 139 129 120 199 191 178 170 161 199 191 178 169 160 199 192 178 166 154 192 184 172 164 155 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50E1001-C-7x 80 BXRC-50E1001-D-7x 80 BXRC-50G1001-B-7x 90 BXRC-50G1001-C-7x 90 BXRC-50G1001-D-7x 90 BXRC-57C1001-B-7x 70 BXRC-57C1001-C-7x 70 BXRC-57C1001-D-7x 70 BXRC-57E1001-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1144 1498 2151 3132 4001 834 1094 1562 2300 2946 743 974 1394 2046 2621 989 1295 1859 2707 3458 721 946 1351 1988 2547 869 1140 1631 2393 3066 1156 1515 2175 3167 4046 844 1107 1580 2326 2980 826 1083 1549 2273 2912 1020 1331 1936 2721 3425 759 984 1406 1983 2481 668 874 1255 1820 2320 882 1150 1673 2352 2960 656 851 1215 1714 2145 781 1022 1468 2129 2714 1032 1346 1958 2752 3463 767 995 1422 2006 2509 742 971 1394 2022 2577 191 184 172 163 154 191 185 172 160 148 166 159 148 142 134 165 159 148 141 133 165 160 148 138 128 194 186 174 166 157 193 186 174 165 155 193 187 174 162 150 184 177 165 157 149 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E1001-C-7x 80 BXRC-57E1001-D-7x 80 BXRC-65C1001-B-7x 70 BXRC-65C1001-C-7x 70 BXRC-65C1001-D-7x 70 BXRC-65E1001-B-7x 80 BXRC-65E1001-C-7x 80 BXRC-65E1001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 1098 1439 2066 3008 3843 801 1051 1501 2209 2830 869 1140 1631 2393 3066 1156 1515 2175 3167 4046 844 1107 1580 2326 2980 835 1095 1568 2300 2946 1111 1456 2090 3044 3888 811 1063 1518 2235 2863 980 1278 1859 2613 3289 729 945 1351 1905 2383 781 1022 1468 2129 2714 1032 1346 1958 2752 3463 767 995 1422 2006 2509 751 982 1411 2046 2608 992 1293 1881 2644 3328 737 956 1366 1927 2411 184 176 165 156 148 184 178 165 154 142 194 186 174 166 157 193 186 174 165 155 193 187 174 162 150 186 179 167 159 151 186 178 167 158 149 186 180 167 155 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.49 30.9 38.5 -16.1 0.56 32.1 39.9 37.4 -16.1 0.37 30.9 38.5 36.1 38.8 -16.1 0.45 32.1 39.9 24.1 26.0 28.0 -11.8 0.49 23.1 28.7 26.3 28.4 30.5 -11.8 0.57 25.3 31.3 Minimum Typical Maximum 270 32.2 34.8 37.4 -16.1 540 33.4 36.1 38.8 360 32.2 34.8 720 33.4 350 700 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 19 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 270 RG1 RG1 RG1 RG1 405 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 360 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 720 RG1 RG2 RG2 RG2 350 RG1 RG1 RG1 RG1 525 RG1 RG1 RG1 RG2 700 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 20 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x Maximum Drive Current3 540mA 720mA 700mA Maximum Peak Pulsed Drive Current4 770mA 1030mA 1000mA Maximum Reverse Voltage5 -60V -60V -45V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 21 Performance Curves Figure 1: Vero 10B Drive Current vs. Voltage Figure 2: Vero 10C Drive Current vs. Voltage 800 600 700 Forward Current (mA) Forward Current (mA) 500 400 300 200 100 0 600 500 400 300 200 100 32 33 34 35 36 37 0 38 32 33 34 Forward Voltage (V) Figure 3: Vero 10D Drive Current vs. Voltage 36 37 38 Figure 4: Vero 10B Typical Relative Flux vs. Current 200% 800 180% 700 160% 600 Relative Luminous Flux Forward Current (mA) 35 Forward Voltage (V) 500 400 300 200 140% 120% 100% 80% 60% 40% 100 0 20% 24 25 26 27 28 0% 29 0 100 200 Forward Voltage (V) Figure 5: Vero 10C Typical Relative Flux vs. Current 400 500 600 Figure 6 Vero 10D Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux 300 Forward Current (mA) 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0% 0 100 200 300 400 500 Forward Current (mA) 600 700 800 0 100 200 300 400 500 600 700 800 Forward Current (mA) Notes for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 22 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature Figure 7: Typical DC Flux vs. Case Temperature 0 103% Neutral White 50 75 100 125 0.000 Cool White 25°C Pulsed 97% -0.003 ccy Shift Relative Luminous Flux 100% 25 0.003 Warm White 94% 91% -0.006 -0.009 88% Warm White -0.012 85% -0.015 82% 0 25 50 75 100 Neutral White Cool White 25°C Pulsed 125 Case Temperature (°C) Case Temperature (°C) Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: Typical DC ccx Shift vs. Case Temperature 0.4101 0 25 50 75 100 0.41 125 0.000 0.4099 0.4098 -0.002 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 ccy ccx Shift -0.004 -0.006 65°C 0.4093 Warm White -0.012 0.4095 0.4094 -0.008 -0.010 45°C 0.4096 Neutral White 85°C 0.4092 Cool White 25°C Pulsed 105°C 0.4091 Case Temperature (°C) 0.409 0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532 ccx Notes for Figures 7 - 9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 23 Performance Curves Figure 11: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 12: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 25°C 0.4090 45°C 0.4010 45°C ccy ccy 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.3950 0.4323 0.4572 0.4574 0.4576 0.4578 0.4328 0.4333 0.458 Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature3 Pulsed Center Point Tc=25°C 25°C 15°C 0.368 25°C 0.401 0.367 0.4 0.366 45°C ccy ccy 0.369 15°C 0.399 0.4343 65°C 0.398 0.397 0.4353 Pulsed Center Point Tc=25°C 45°C 0.365 0.364 70°C 0.363 85°C 0.4348 Figure 14: 3000K Class A Color Shift vs. Case Temperature1 0.403 0.402 0.4338 ccx ccx 85°C 0.362 105°C 0.396 0.395 0.444 0.361 0.4445 0.445 0.4455 0.446 0.4465 0.447 105°C 0.36 0.416 0.4165 0.417 ccx Figure 15: 3500K Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 16: 4000K Class A Color Shift vs. Case Temperature1 0.37 15°C 0.368 25°C 15°C 0.3740 25°C 0.3720 45°C 45°C 0.3700 0.364 70°C 0.362 0.3680 85°C 70°C 0.3660 0.36 85°C 0.3640 105°C 0.358 0.392 Pulsed Center Point Tc=25°C ccy ccy 0.366 0.3760 Pulsed Center Point Tc=25°C 105°C 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 10-16: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G100C-x-73 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 24 Typical Radiation Pattern Figure 17: Typical Spatial Radiation Pattern Note for Figure 17: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 18: Typical Polar Radiation Pattern 25 Typical Color Spectrum Figure 19: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 19: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 20: Typical Color Spectrum for Vero 10 with Décor Series 1 20B 27H 0.9 30G (Décor Series Showcase) 30H Relative Spectral Power Distribution 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 20: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 26 Mechanical Dimensions Figure 21: Drawing for Vero 10 LED Array Notes for Figure 21: 1. Drawings are not to scale. 2. Dimensions are in mm. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting slots (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 19.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 27 Color Binning Information Figure 22: Warm and Neutral White Test Bins in xy Color Figure 23: Graph of Cool White Test Bins in xy Color Space Space 0.44 0.39 4 SDCM 3 SDCM 2000K 3SDCM 2 SDCM 0.42 2700K 0.37 3000K 5000K 0.36 3500K 0.4 3 SDCM 0.38 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2000K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5280, 0.4100) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5481K - 5829K) (6270K - 6765K) 73 (3 SDCM) (4835K-5215K) (5490K-5820K) (6250K-6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 28 Packaging and Labeling Figure 24: Drawing for Vero 10 Packaging Tray Notes for Figure 24: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 29 Packaging and Labeling Figure 25: Vero Series Packaging and Labeling Notes for Figure 25: 1. Each tray holds 200 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 26: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 31 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2019 Bridgelux, Inc. All rights reserved. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 10 Array Series Product Data Sheet DS90 Rev. P (03/2019) 32
BXRC-50E1001-D-74 价格&库存

很抱歉,暂时无法提供与“BXRC-50E1001-D-74”相匹配的价格&库存,您可以联系我们找货

免费人工找货