0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BXRC-27E1000-D-72

BXRC-27E1000-D-72

  • 厂商:

    BRIDGELUX

  • 封装:

    -

  • 描述:

    LEDCOBVERO102700KSTARBOARD

  • 数据手册
  • 价格&库存
BXRC-27E1000-D-72 数据手册
Bridgelux Gen 7 Vero 10 Array ® ® Product Data Sheet DS90 1 Vero® Series Introduction Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents. Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color control standard for clean and consistent uniform lighting. Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting features for plug-and-play installation. Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD. Décor Series™ Class A is based on human response testing, providing color points with a combined GAI and CRI metric. Décor Series™ Ultra products provide a high CRI of 97 and minimum R9 value of 93, which emphasizes the reds and color tones to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor Series Ultra is designed as a replacement for halogen lamps. Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps. Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white light with enhanced spectrum coverage and higher efficacy. Features • Efficacy of 155 lm/W typical • Lumen output performance ranges from 520 to 4,100 lumens • Broad range of CCT options from 2700K to 6500K • CRI options include minimum 65, 70, 80, and 90 • 2 and 3 SDCM color control for 2700K-4000K CCT • Reliable operation at up to 2X nominal drive current • Radial die pattern and improved lumen density Benefits • Broad application coverage for interior and exterior lighting • Flexibility for application driven lighting design requirements • High quality true color reproduction • Uniform consistent white light • Flexibility in design optimization • Enhanced ease of use and assembly • Thermally isolated solder pads • Solderless connectivity enables plug & play installation and field upgradability • On-board connector port • Improved inventory management and quality control • Top side part number markings • Vf bin code backside marking Contents Product Feature Map 2 Product Nomenclature 2 Product Selection Guide 3 Performance at Commonly Used Drive Currents 10 Electrical Characteristics 19 Eye Safety 20 Absolute Maximum Ratings 21 Performance Curves 22 Typical Radiation Pattern 25 Typical Color Spectrum 26 Mechanical Dimensions 27 Color Binning Information 28 Packaging and Labeling 29 Design Resources 31 Precautions 31 Disclaimers 31 About Bridgelux 32 1 Product Feature Map Vero 10 is the smallest form factor in the Vero family of next generation solid state light sources. In addition to delivering the performance and light quality required for many lighting applications, Vero incorporates several features to simplify the design integration and manufacturing process, accelerate time to market and reduce system costs. Please visit www.bridgelux.com for more information on the Vero Series family of products. 2D Bar code provides full manufacturing traceability Thermally isolated solder pads reduce manufacturing cycle time and complexity Polarity indication marks simplify manufacturing operator instructions Tc Measurement point Mounting holes Top side part number marking improves inventory management and outgoing quality control Radial die configuration improves lumen density and beam control Solderless connector port enables simplified manufacturing processes, reduced inventory carrying costs and can enable field upgradability Optional Molex Pico-EZmate™ connector harness (sold separately) Product Nomenclature The part number designation for Bridgelux Vero LED arrays is explained as follows: 1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14 BXRC – 30 E 100 0 – C – 7 3 CCT Bin Options Product Family Nominal CCT 20 = 2,000K 27 = 2,700K 30 = 3,000K 35 = 3,500K 40 = 4,000K 50 = 5,000K 57 = 5,700K 65 = 6,500K Gen. 7 2 = 2 SDCM 3 = 3 SDCM 4 = 4 SDCM Array Configuration CRI B = 65 CRI min. C = 70 CRI min. E = 80 CRI min. G = 90 CRI min. H = 97 CRI typ. A = Class A Color Targeting Designator 0 = Cold Targeted 1 = Hot Targeted C = Decor Series Showcase Target Flux Indicator 100x = 1000 lm 2 Product Selection Guide The following product configurations are available: Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 145 BXRC-20B1000-B-73 2000 65 270 1365 1201 34.8 9.4 BXRC-20B1000-D-73 2000 65 350 1322 1163 26.0 9.1 145 BXRC-27E1000-B-7x 2700 80 270 1394 1226 34.8 9.4 148 BXRC-27E1000-C-7x 2700 80 360 1858 1635 34.8 12.5 148 BXRC-27E1000-D-7x 2700 80 350 1350 1188 26.0 9.1 148 BXRC-27G10H0-B-7x 2700 90 270 1203 1058 34.8 9.4 128 BXRC-27G10H0-C-7x 2700 90 360 1604 1411 34.8 12.5 128 BXRC-27G10H0-D-7x 2700 90 350 1165 1025 26.0 9.1 128 BXRC-27G1000-B-7x 2700 90 270 1161 1022 34.8 9.4 124 BXRC-27G1000-C-7x 2700 90 360 1548 1363 34.8 12.5 124 BXRC-27G1000-D-7x 2700 90 350 1125 990 26.0 9.1 124 BXRC-27H1000-B-7x 2700 97 270 1006 886 34.8 9.4 107 BXRC-27H1000-C-7x 2700 97 360 1342 1181 34.8 12.5 107 BXRC-27H1000-D-7x 2700 97 350 975 858 26.0 9.1 107 BXRC-30C1001-B-74 3000 70 270 1607 1414 34.8 9.4 171 BXRC-30C1001-C-74 3000 70 360 2142 1885 34.8 12.5 171 BXRC-30C1001-D-74 3000 70 350 1556 1369 26.0 9.1 171 BXRC-30E1000-B-7x 3000 80 270 1452 1277 34.8 9.4 155 BXRC-30E1000-C-7x 3000 80 360 1936 1703 34.8 12.5 155 BXRC-30E1000-D-7x 3000 80 350 1406 1237 26.0 9.1 155 BXRC-30G10H0-B-7x 3000 90 270 1268 1116 34.8 9.4 135 BXRC-30G10H0-C-7x 3000 90 360 1691 1488 34.8 12.5 135 BXRC-30G10H0-D-7x 3000 90 350 1229 1081 26.0 9.1 135 BXRC-30G1000-B-7x 3000 90 270 1210 1065 34.8 9.4 129 BXRC-30G1000-C-7x 3000 90 360 1613 1419 34.8 12.5 129 BXRC-30G1000-D-7x 3000 90 350 1172 1031 26.0 9.1 129 BXRC-30G100C-B-73 3000 90 270 1123 988 34.8 9.4 119 BXRC-30G100C-D-73 3000 90 350 1087 957 26.0 9.1 119 BXRC-30H1000-B-7x 3000 97 270 1084 954 34.8 9.4 115 BXRC-30H1000-C-7x 3000 97 360 1445 1272 34.8 12.5 115 BXRC-30H1000-D-7x 3000 97 350 1050 924 26.0 9.1 115 BXRC-30A1001-B-73 3000 93 270 1090 959 34.8 9.4 116 8,9 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI Nominal Drive Current3 (mA) 2 Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A1001-C-738,9 3000 93 360 1453 1279 34.8 12.5 116 BXRC-30A1001-D-738,9 3000 93 350 1056 929 26.0 9.1 116 BXRC-35E1000-B-7x 3500 80 270 1500 1320 34.8 9.4 160 BXRC-35E1000-C-7x 3500 80 360 2000 1760 34.8 12.5 160 BXRC-35E1000-D-7x 3500 80 350 1453 1278 26.0 9.1 160 BXRC-35G1000-B-7x 3500 90 270 1248 1099 34.8 9.4 133 BXRC-35G1000-C-7x 3500 90 360 1665 1465 34.8 12.5 133 BXRC-35G1000-D-7x 3500 90 350 1209 1064 26.0 9.1 133 BXRC-35A1001-B-738,9 3500 93 270 1175 1034 34.8 9.4 125 BXRC-35A1001-C-738,9 3500 93 360 1566 1378 34.8 12.5 125 BXRC-35A1001-D-738,9 3500 93 350 1138 1001 26.0 9.1 125 BXRC-40C1001-B-74 4000 70 270 1635 1439 34.8 9.4 174 BXRC-40C1001-C-74 4000 70 360 2180 1918 34.8 12.5 174 BXRC-40C1001-D-74 4000 70 350 1583 1393 26.0 9.1 174 BXRC-40E1000-B-7x 4000 80 270 1510 1329 34.8 9.4 161 BXRC-40E1000-C-7x 4000 80 360 2013 1771 34.8 12.5 161 BXRC-40E1000-D-7x 4000 80 350 1462 1287 26.0 9.1 161 BXRC-40G1000-B-7x 4000 90 270 1297 1141 34.8 9.4 138 BXRC-40G1000-C-7x 4000 90 360 1729 1522 34.8 12.5 138 BXRC-40G1000-D-7x 4000 90 350 1256 1105 26.0 9.1 138 BXRC-40H1000-B-7x 4000 97 270 1109 976 34.8 9.4 118 118 BXRC-40H1000-C-7x 4000 97 360 1478 1301 34.8 12.5 BXRC-40H1000-D-7x 4000 97 350 1074 945 26.0 9.1 118 BXRC-40A1001-B-738,9 4000 93 270 1250 1100 34.8 9.4 133 BXRC-40A1001-C-738,9 4000 93 360 1666 1466 34.8 12.5 133 BXRC-40A1001-D-738,9 4000 93 350 1210 1065 26.0 9.1 133 BXRC-50C1001-B-7x 5000 70 270 1655 1456 34.8 9.4 176 BXRC-50C1001-C-7x 5000 70 360 2207 1942 34.8 12.5 176 BXRC-50C1001-D-7x 5000 70 350 1603 1410 26.0 9.1 176 BXRC-50E1001-B-7x 5000 80 270 1558 1371 34.8 9.4 166 BXRC-50E1001-C-7x 5000 80 360 2078 1828 34.8 12.5 166 BXRC-50E1001-D-7x 5000 80 350 1509 1328 26.0 9.1 166 BXRC-50G1001-B-7x 5000 90 270 1316 1158 34.8 9.4 140 BXRC-50G1001-C-7x 5000 90 360 1755 1544 34.8 12.5 140 BXRC-50G1001-D-7x 5000 90 350 1275 1122 26.0 9.1 140 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 4 Product Selection Guide Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued) Part Number Nominal CCT1 (K) CRI 2 Nominal Drive Current3 (mA) Typical Pulsed Flux4,5,6 Tc = 25ºC (lm) Minimum Pulsed Flux6,7 Tc = 25ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-57C1001-B-7x 5700 70 270 1597 1405 34.8 9.4 170 BXRC-57C1001-C-7x 5700 70 360 2129 1874 34.8 12.5 170 BXRC-57C1001-D-7x 5700 70 350 1547 1361 26.0 9.1 170 BXRC-57E1001-B-7x 5700 80 270 1541 1356 34.8 9.4 164 BXRC-57E1001-C-7x 5700 80 360 2055 1808 34.8 12.5 164 BXRC-57E1001-D-7x 5700 80 350 1492 1313 26.0 9.1 164 BXRC-65C1001-B-7x 6500 70 270 1626 1431 34.8 9.4 173 BXRC-65C1001-C-7x 6500 70 360 2168 1908 34.8 12.5 173 BXRC-65C1001-D-7x 6500 70 350 1575 1386 26.0 9.1 173 BXRC-65E1001-B-7x 6500 80 270 1569 1381 34.8 9.4 167 BXRC-65E1001-C-7x 6500 80 360 2092 1841 34.8 12.5 167 BXRC-65E1001-D-7x 6500 80 350 1520 1337 26.0 9.1 167 Notes for Table 1: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Minimum flux values at the nominal test current are guaranteed by 100% test. 8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 5 Product Selection Guide Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8 Part Number Nominal CCT1 (K) GAI2 CRI3 Nominal Drive Current4 (mA) Typical DC Flux5,6 Tc = 70ºC (lm) Minimum DC Flux6,9 Tc = 70ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-30A1001-B-73 3000 80 93 270 1014 844 34.3 9.3 110 BXRC-30A1001-C-73 3000 80 93 360 1352 1125 34.3 12.3 110 BXRC-30A1001-D-73 3000 80 93 350 982 817 25.5 8.9 110 BXRC-35A1001-B-73 3500 80 93 270 1092 1162 34.3 9.3 118 BXRC-35A1001-C-73 3500 80 93 360 1456 1549 34.3 12.3 118 BXRC-35A1001-D-73 3500 80 93 350 1058 1125 25.5 8.9 119 BXRC-40A1001-B-73 4000 80 93 270 1162 967 34.3 9.3 126 BXRC-40A1001-C-73 4000 80 93 360 1550 1289 34.3 12.3 126 BXRC-40A1001-D-73 4000 80 93 350 1126 936 25.5 8.9 126 Notes for Table 2: 1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C.  GAI may vary depending on fixture design and performance. 3. CRI Values are specified as typical. 4. Drive current is referred to as nominal drive current. 5. Typical performance values are provided as a reference only and are not a guarantee of performance. 6. Bridgelux maintains a ±7% tolerance on flux measurements. 7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-20B1000-B-73 2000 65 270 1228 1081 33.8 9.1 135 BXRC-20B1000-D-73 2000 65 350 1189 1047 25.3 8.9 134 BXRC-27E1000-B-7x 2700 80 270 1254 1104 33.8 9.1 137 BXRC-27E1000-C-7x 2700 80 360 1672 1472 33.8 12.2 137 BXRC-27E1000-D-7x 2700 80 350 1215 1069 25.3 8.9 137 BXRC-27G10H0-B-7x 2700 90 270 1082 953 33.8 9.1 118 BXRC-27G10H0-C-7x 2700 90 360 1443 1270 33.8 12.2 118 BXRC-27G10H0-D-7x 2700 90 350 1048 923 25.3 8.9 118 BXRC-27G1000-B-7x 2700 90 270 1045 920 33.8 9.1 114 BXRC-27G1000-C-7x 2700 90 360 1394 1226 33.8 12.2 114 BXRC-27G1000-D-7x 2700 90 350 1012 891 25.3 8.9 114 BXRC-27H1000-B-7x 2700 97 270 906 797 34.8 9.4 96 BXRC-27H1000-C-7x 2700 97 360 1208 1063 34.8 12.5 96 BXRC-27H1000-D-7x 2700 97 350 877 772 34.8 12.2 72 BXRC-30C1001-B-74 3000 70 270 1446 1273 33.8 9.1 158 BXRC-30C1001-C-74 3000 70 360 1928 1697 33.8 12.2 158 BXRC-30C1001-D-74 3000 70 350 1400 1232 25.3 8.9 158 BXRC-30E1000-B-7x 3000 80 270 1307 1150 33.8 9.1 143 BXRC-30E1000-C-7x 3000 80 360 1742 1533 33.8 12.2 143 BXRC-30E1000-D-7x 3000 80 350 1265 1114 25.3 8.9 143 BXRC-30G10H0-B-7x 3000 90 270 1142 1005 33.8 9.1 125 BXRC-30G10H0-C-7x 3000 90 360 1522 1339 33.8 12.2 125 BXRC-30G10H0-D-7x 3000 90 350 1106 973 25.3 8.9 125 BXRC-30G1000-B-7x 3000 90 270 1089 958 33.8 9.1 119 BXRC-30G1000-C-7x 3000 90 360 1452 1277 33.8 12.2 119 BXRC-30G1000-D-7x 3000 90 350 1054 928 25.3 8.9 119 BXRC-30G100C-B-73 3000 90 270 1010 889 34.0 9.2 110 BXRC-30G100C-D-73 3000 90 350 979 861 25.3 8.9 111 BXRC-30H1000-B-7x 3000 97 270 976 858 34.8 9.4 104 104 BXRC-30H1000-C-7x 3000 97 360 1301 1145 34.8 12.5 BXRC-30H1000-D-7x 3000 97 350 945 831 34.8 12.2 78 BXRC-30A1001-B-737,8 3000 93 270 981 863 34.8 9.4 104 BXRC-30A1001-C-737,8 3000 93 360 1308 1151 34.8 12.5 104 BXRC-30A1001-D-73 3000 93 350 950 836 34.8 12.2 78 3500 80 270 1350 1188 33.8 9.1 148 7,8 BXRC-35E1000-B-7x Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 7 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued) Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) BXRC-35E1000-C-7x 3500 80 360 1800 1584 33.8 12.2 148 BXRC-35E1000-D-7x 3500 80 350 1308 1151 25.3 8.9 148 BXRC-35G1000-B-7x 3500 90 270 1124 989 33.8 9.1 123 BXRC-35G1000-C-7x 3500 90 360 1498 1318 33.8 12.2 123 BXRC-35G1000-D-7x 3500 90 350 1088 958 25.0 8.8 124 BXRC-35A1001-B-737,8 3500 93 270 1057 930 33.8 9.1 116 BXRC-35A1001-C-737,8 3500 93 360 1409 1240 33.8 12.2 116 BXRC-35A1001-D-737,8 3500 93 350 1024 901 25.0 8.8 117 BXRC-40C1001-B-74 4000 70 270 1471 1295 33.8 9.1 161 161 BXRC-40C1001-C-74 4000 70 360 1962 1726 33.8 12.2 BXRC-40C1001-D-74 4000 70 350 1425 1254 25.3 8.9 161 BXRC-40E1000-B-7x 4000 80 270 1359 1196 33.8 9.1 149 BXRC-40E1000-C-7x 4000 80 360 1812 1594 33.8 12.2 149 BXRC-40E1000-D-7x 4000 80 350 1316 1158 25.0 8.8 150 BXRC-40G1000-B-7x 4000 90 270 1167 1027 33.8 9.1 128 BXRC-40G1000-C-7x 4000 90 360 1556 1369 33.8 12.2 128 BXRC-40G1000-D-7x 4000 90 350 1130 995 25.0 8.8 129 BXRC-40H1000-B-7x 4000 97 270 998 878 33.8 9.1 109 BXRC-40H1000-C-7x 4000 97 360 1330 1171 33.8 12.2 109 BXRC-40H1000-D-7x 4000 97 350 966 850 25.0 8.8 110 BXRC-40A1001-B-737,8 4000 93 270 1125 990 33.8 9.1 123 BXRC-40A1001-C-737,8 4000 93 360 1500 1320 33.8 12.2 123 BXRC-40A1001-D-737,8 4000 93 350 1089 959 25.0 8.8 124 BXRC-50C1001-B-7x 5000 70 270 1489 1311 33.8 9.1 163 BXRC-50C1001-C-7x 5000 70 360 1986 1748 33.8 12.2 163 BXRC-50C1001-D-7x 5000 70 350 1443 1269 25.0 8.8 165 BXRC-50E1001-B-7x 5000 80 270 1402 1234 33.8 9.1 154 BXRC-50E1001-C-7x 5000 80 360 1870 1645 33.8 12.2 154 BXRC-50E1001-D-7x 5000 80 350 1358 1195 25.0 8.8 155 BXRC-50G1001-B-7x 5000 90 270 1185 1042 33.8 9.1 130 BXRC-50G1001-C-7x 5000 90 360 1579 1390 33.8 12.2 130 BXRC-50G1001-D-7x 5000 90 350 1147 1010 25.0 8.8 131 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 8 Product Selection Guide Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 Part Number Nominal CCT1 (K) CRI2 Nominal Drive Current3 (mA) Typical DC Flux4,5 Tc = 85ºC (lm) Minimum DC Flux6 Tc = 85ºC (lm) Typical Vf (V) Typical Power (W) Typical Efficacy (lm/W) 157 BXRC-57C1001-B-7x 5700 70 270 1437 1265 33.8 9.1 BXRC-57C1001-C-7x 5700 70 360 1916 1686 33.8 12.2 157 BXRC-57C1001-D-7x 5700 70 350 1392 1225 25.0 8.8 159 152 BXRC-57E1001-B-7x 5700 80 270 1387 1220 33.8 9.1 BXRC-57E1001-C-7x 5700 80 360 1849 1627 33.8 12.2 152 BXRC-57E1001-D-7x 5700 80 350 1343 1182 25.0 8.8 153 BXRC-65C1001-B-7x 6500 70 270 1463 1288 33.8 9.1 160 BXRC-65C1001-C-7x 6500 70 360 1951 1717 33.8 12.2 160 BXRC-65C1001-D-7x 6500 70 350 1417 1247 25.0 8.8 162 BXRC-65E1001-B-7x 6500 80 270 1412 1243 33.8 9.1 155 BXRC-65E1001-C-7x 6500 80 360 1883 1657 33.8 12.2 155 BXRC-65E1001-D-7x 6500 80 350 1368 1204 25.0 8.8 156 Notes for Table 3: 1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C. 2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on CRI and R9 values. 3. Drive current is referred to as nominal drive current. 4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected. 7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line. 8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on fixture design and performance. 9 Performance at Commonly Used Drive Currents Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also be driven at other drive currents dependent on specific application design requirements. The performance at any drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4. Table 4: Product Performance at Commonly Used Drive Currents Part Number CRI BXRC-20B1001-B-73 65 BXRC-20B1001-D-73 65 BXRC-27E1000-B-7x 80 BXRC-27E1000-C-7x 80 BXRC-27E1000-D-7x 80 BXRC-27G10H0-B-7x 90 BXRC-27G10H0-C-7x 90 BXRC-27G10H0-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 727 953 1365 2002 2565 706 926 1322 1945 2492 743 974 1394 2045 2619 988 1294 1858 2706 3456 721 945 1350 1987 2545 641 840 1203 1764 2260 853 1117 1604 2335 2983 622 816 1165 1714 2197 653 855 1228 1781 2270 642 832 1189 1678 2099 667 873 1254 1819 2318 882 1150 1672 2351 2959 655 850 1215 1713 2143 576 754 1082 1570 2001 761 992 1443 2029 2553 566 734 1048 1479 1850 162 156 145 139 131 162 156 145 135 125 166 159 148 142 134 165 159 148 141 133 165 160 148 138 128 143 137 128 122 116 143 137 128 121 115 143 138 128 119 110 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 10 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-27G1000-B-7x 90 BXRC-27G1000-C-7x 90 BXRC-27G1000-D-7x 90 BXRC-27H1000-B-7x 97 BXRC-27H1000-C-7x 97 BXRC-27H1000-D-7x 97 BXRC-30C1001-B-74 70 BXRC-30C1001-C-74 70 BXRC-30C1001-D-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 619 811 1161 1704 2183 823 1079 1548 2255 2880 601 788 1125 1656 2121 536 703 1006 1477 1892 713 935 1342 1954 2496 520 683 975 1435 1838 856 1123 1607 2357 3020 1139 1492 2142 3119 3985 831 1090 1556 2290 2934 556 728 1045 1516 1932 735 958 1394 1959 2465 546 708 1012 1428 1786 482 631 906 1314 1674 637 830 1208 1698 2137 473 614 877 1237 1548 769 1007 1446 2097 2673 1016 1326 1928 2710 3411 755 980 1400 1975 2471 138 133 124 118 112 138 132 124 117 111 138 133 124 115 107 120 115 107 102 97 119 115 107 102 96 119 115 107 100 92 191 183 171 163 155 191 183 171 162 153 190 184 171 159 148 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 11 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30E1000-B-7x 80 BXRC-30E1000-C-7x 80 BXRC-30E1000-D-7x 80 BXRC-30G10H0-B-7x 90 BXRC-30G10H0-C-7x 90 BXRC-30G10H0-D-7x 90 BXRC-30G1000-B-7x 90 BXRC-30G1000-C-7x 90 BXRC-30G1000-D-7x 90 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 774 1014 1452 2130 2728 1029 1348 1936 2818 3600 751 985 1406 2069 2651 676 886 1268 1861 2384 899 1178 1691 2463 3146 656 861 1229 1808 2317 645 845 1210 1775 2274 858 1124 1613 2349 3000 626 821 1172 1725 2209 695 910 1307 1895 2415 918 1198 1742 2448 3082 683 885 1265 1785 2233 607 795 1142 1655 2110 802 1047 1522 2139 2693 596 774 1106 1560 1951 579 758 1089 1579 2012 765 998 1452 2040 2568 569 738 1054 1487 1861 173 166 155 148 140 172 165 155 146 138 172 166 155 144 133 151 145 135 129 122 150 144 135 128 121 150 145 135 126 116 144 138 129 123 116 143 138 129 122 115 143 139 129 120 111 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 12 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-30G100C-B-73 90 BXRC-30G100C-D-73 90 BXRC-30H1000-B-7x 97 BXRC-30H1000-C-7x 97 BXRC-30H1000-D-7x 97 BXRC-30A1001-B-73 93 BXRC-30A1001-C-73 93 BXRC-30A1001-D-73 93 BXRC-35E1000-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 135 180 270 405 540 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 4.5 6.1 9.4 14.4 19.5 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 598 784 1123 1647 2110 581 762 1087 1600 2050 578 757 1084 1590 2037 768 1007 1445 2104 2688 561 735 1050 1545 1980 581 762 1090 1599 2049 773 1012 1453 2116 2703 564 739 1056 1554 1991 799 1048 1500 2201 2819 538 704 1010 1465 1868 528 685 979 1380 1727 519 679 976 1415 1803 686 894 1301 1828 2301 510 661 945 1333 1667 522 683 981 1422 1813 689 899 1308 1838 2314 512 665 950 1340 1676 718 940 1350 1958 2495 133 128 119 114 108 133 129 119 111 103 129 124 115 110 104 129 123 115 109 103 129 124 115 108 100 130 124 116 111 105 129 124 116 110 104 129 125 116 108 100 178 171 160 152 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 13 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-35E1000-C-7x 80 BXRC-35E1000-D-7x 80 BXRC-35G1000-B-7x 90 BXRC-35G1000-C-7x 90 BXRC-35G1000-D-7x 90 BXRC-35A1001-B-73 93 BXRC-35A1001-C-73 93 BXRC-35A1001-D-73 93 BXRC-40C1001-B-74 70 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1063 1393 2000 2912 3720 776 1018 1453 2138 2740 665 872 1248 1832 2346 885 1159 1665 2424 3096 646 847 1209 1780 2280 626 821 1175 1723 2207 833 1091 1566 2280 2913 607 797 1138 1674 2145 871 1142 1635 2399 3073 949 1238 1800 2530 3185 705 915 1308 1844 2307 598 782 1124 1629 2077 790 1030 1498 2106 2650 587 761 1088 1535 1920 562 736 1057 1533 1954 743 969 1409 1981 2493 552 716 1024 1444 1806 783 1025 1471 2134 2720 178 171 160 151 143 178 172 160 149 138 148 143 133 127 120 148 142 133 126 119 148 143 133 124 115 140 134 125 119 113 139 134 125 118 112 139 135 125 117 108 194 187 174 166 157 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 14 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40C1001-C-74 70 BXRC-40C1001-D-74 70 BXRC-40E1000-B-7x 80 BXRC-40E1000-C-7x 80 BXRC-40E1000-D-7x 80 BXRC-40G1000-B-7x 90 BXRC-40G1000-C-7x 90 BXRC-40G1000-D-7x 90 BXRC-40H1000-B-7x 97 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1159 1518 2180 3174 4055 845 1109 1583 2331 2986 805 1055 1510 2215 2838 1070 1402 2013 2931 3744 781 1024 1462 2152 2757 691 906 1297 1903 2437 919 1204 1729 2518 3216 671 880 1256 1849 2369 591 775 1109 1627 2084 1034 1349 1962 2757 3471 769 997 1425 2010 2514 723 946 1359 1970 2511 955 1246 1812 2546 3205 710 921 1316 1856 2322 621 813 1167 1692 2157 820 1070 1556 2187 2753 610 791 1130 1594 1994 531 695 998 1447 1844 194 186 174 165 156 194 187 174 162 150 179 172 161 153 145 179 172 161 152 144 179 173 161 150 139 154 148 138 132 125 154 148 138 131 124 154 149 138 129 119 132 127 118 113 107 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 15 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-40H1000-C-7x 97 BXRC-40H1000-D-7x 97 BXRC-40A1001-B-73 93 BXRC-40A1001-C-73 93 BXRC-40A1001-D-73 93 BXRC-50C1001-B-7x 70 BXRC-50C1001-C-7x 70 BXRC-50C1001-D-7x 70 BXRC-50E1001-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 786 1030 1478 2153 2750 573 752 1074 1581 2025 666 873 1250 1833 2349 886 1161 1666 2426 3099 646 848 1210 1781 2282 882 1156 1655 2428 3110 1173 1537 2207 3213 4104 856 1123 1603 2359 3023 830 1089 1558 2286 2929 701 915 1330 1870 2354 521 676 966 1363 1705 598 783 1125 1631 2079 790 1031 1500 2108 2653 588 762 1089 1536 1922 792 1037 1489 2160 2753 1047 1365 1986 2791 3513 778 1009 1443 2035 2545 746 976 1402 2033 2592 131 126 118 112 106 131 127 118 110 102 149 143 133 127 120 148 142 133 126 119 148 143 133 124 115 197 189 176 168 159 196 188 176 167 158 196 190 176 164 152 185 178 166 158 150 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 16 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-50E1001-C-7x 80 BXRC-50E1001-D-7x 80 BXRC-50G1001-B-7x 90 BXRC-50G1001-C-7x 90 BXRC-50G1001-D-7x 90 BXRC-57C1001-B-7x 70 BXRC-57C1001-C-7x 70 BXRC-57C1001-D-7x 70 BXRC-57E1001-B-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 1105 1447 2078 3025 3864 806 1057 1509 2221 2846 701 920 1316 1931 2474 933 1222 1755 2555 3264 681 893 1275 1876 2404 851 1116 1597 2343 3001 1132 1483 2129 3100 3960 826 1083 1547 2276 2916 821 1077 1541 2261 2896 986 1286 1870 2628 3308 733 950 1358 1916 2396 630 825 1185 1718 2189 833 1086 1579 2220 2794 619 803 1147 1618 2024 765 1001 1437 2084 2656 1010 1317 1916 2693 3390 751 974 1392 1963 2456 738 966 1387 2011 2563 185 177 166 157 148 185 179 166 155 143 156 150 140 134 127 156 150 140 133 125 156 151 140 131 121 190 182 170 162 154 189 182 170 161 152 189 183 170 158 147 183 176 164 157 148 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 17 Performance at Commonly Used Drive Currents Table 4: Product Performance at Commonly Used Drive Currents (Continued) Part Number CRI BXRC-57E1001-C-7x 80 BXRC-57E1001-D-7x 80 BXRC-65C1001-B-7x 70 BXRC-65C1001-C-7x 70 BXRC-65C1001-D-7x 70 BXRC-65E1001-B-7x 80 BXRC-65E1001-C-7x 80 BXRC-65E1001-D-7x 80 Drive Current1 (mA) Typical Vf Tc = 25ºC (V) Typical Power Tc = 25ºC (W) Typical Flux2 Tc = 25ºC (lm) Typical DC Flux3 Tc = 85ºC (lm) Typical Efficacy Tc = 25ºC (lm/W) 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 135 180 270 405 540 180 240 360 540 720 175 233 350 525 700 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 33.2 34.0 34.8 35.6 36.1 33.2 34.0 34.8 35.6 36.1 24.9 25.4 26.0 27.4 28.4 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 4.5 6.1 9.4 14.4 19.5 6.0 8.2 12.5 19.2 26.0 4.4 5.9 9.1 14.4 19.9 1092 1431 2055 2992 3822 797 1045 1492 2197 2814 866 1136 1626 2385 3056 1153 1510 2168 3157 4032 841 1103 1575 2318 2970 836 1096 1569 2302 2949 1112 1457 2092 3047 3892 811 1064 1520 2237 2866 975 1271 1849 2599 3271 725 940 1343 1895 2370 779 1019 1463 2122 2705 1028 1341 1951 2742 3452 764 992 1417 1999 2501 751 983 1412 2048 2610 993 1295 1883 2647 3331 738 957 1368 1929 2413 183 175 164 155 147 183 177 164 153 141 193 186 173 165 157 193 185 173 164 155 193 186 173 161 149 186 179 167 160 151 186 179 167 158 150 186 180 167 156 144 Notes for Table 4: 1. Alternate drive currents are provided for reference only and are not a guarantee of performance. 2. Bridgelux maintains a ± 7% tolerance on flux measurements. 3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance. 18 Electrical Characteristics Table 5: Electrical Characteristics Forward Voltage Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Part Number BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x Drive Current (mA) Typical Coefficient of Forward Voltage4 ∆Vf/∆Tc (mV/ºC) Typical Thermal Resistance Junction to Case5,6 Rj-c (ºC/W) Driver Selection Voltages7 (V) Vf Min. Hot Tc = 105ºC (V) Vf Max. Cold Tc = -40ºC (V) 0.49 30.9 38.5 -16.1 0.56 32.1 39.9 37.4 -16.1 0.37 30.9 38.5 36.1 38.8 -16.1 0.45 32.1 39.9 24.1 26.0 28.0 -11.8 0.49 23.1 28.7 26.3 28.4 30.5 -11.8 0.57 25.3 31.3 Minimum Typical Maximum 270 32.2 34.8 37.4 -16.1 540 33.4 36.1 38.8 360 32.2 34.8 720 33.4 350 700 Notes for Table 5: 1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms. 2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance. 3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements. 4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current. 5. Thermal resistance values are based from test data of a 3000K 80 CRI product. 6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface material used during testing is not included in the thermal resistance value. 7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and selection over the operating range of the product. 8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product application. 19 Eye Safety Table 6: Eye Safety Risk Group (RG) Classifications Part Number BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x CCT1,5 Drive Current 5 (mA) 2700K/3000K 4000K2 5000K3 6500K4 270 RG1 RG1 RG1 RG1 405 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 360 RG1 RG1 RG1 RG2 540 RG1 RG1 RG2 RG2 720 RG1 RG2 RG2 RG2 350 RG1 RG1 RG1 RG1 525 RG1 RG1 RG1 RG2 700 RG1 RG1 RG2 RG2 Notes for Table 6: 1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the assessment of blue light hazard to light sources and luminaires. 2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx. 3. For products classified as RG2 at 5000K Ethr= 1315.8 lx. 4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx. 5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed. 20 Absolute Maximum Ratings Table 7: Maximum Ratings Parameter Maximum Rating LED Junction Temperature (Tj) 150°C Storage Temperature -40°C to +105°C Operating Case Temperature1 (Tc) 105°C Soldering Temperature2 300°C or lower for a maximum of 6 seconds BXRC-xxx100x-B-7x BXRC-xxx100x-C-7x BXRC-xxx100x-D-7x Maximum Drive Current3 540mA 720mA 700mA Maximum Peak Pulsed Drive Current4 770mA 1030mA 1000mA Maximum Reverse Voltage5 -60V -60V -45V Notes for Table 7: 1. For IEC 62717 requirement, please consult your Bridgelux sales representative. 2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays. 3. Arrays may be driven at higher currents however lumen maintenance may be reduced. 4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures. 5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating provided for reference only. 21 Performance Curves Figure 1: Vero 10B Drive Current vs. Voltage Figure 2: Vero 10C Drive Current vs. Voltage 800 600 700 Forward Current (mA) Forward Current (mA) 500 400 300 200 100 0 600 500 400 300 200 100 32 33 34 35 36 37 0 38 32 33 34 Forward Voltage (V) Figure 3: Vero 10D Drive Current vs. Voltage 36 37 38 Figure 4: Vero 10B Typical Relative Flux vs. Current 200% 800 180% 700 160% 600 Relative Luminous Flux Forward Current (mA) 35 Forward Voltage (V) 500 400 300 200 140% 120% 100% 80% 60% 40% 100 0 20% 24 25 26 27 28 0% 29 0 100 200 Forward Voltage (V) Figure 5: Vero 10C Typical Relative Flux vs. Current 400 500 600 Figure 6 Vero 10D Typical Relative Flux vs. Current 200% 200% 180% 180% 160% 160% 140% 140% Relative Luminous Flux Relative Luminous Flux 300 Forward Current (mA) 120% 100% 80% 60% 120% 100% 80% 60% 40% 40% 20% 20% 0% 0% 0 100 200 300 400 500 Forward Current (mA) 600 700 800 0 100 200 300 400 500 600 700 800 Forward Current (mA) Notes for Figure 1-6: 1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is recommended for dimming effects. 2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C. 22 Performance Curves Figure 8: Typical DC ccy Shift vs. Case Temperature Figure 7: Typical DC Flux vs. Case Temperature 0 103% Neutral White 50 75 100 125 0.000 Cool White 25°C Pulsed 97% -0.003 ccy Shift Relative Luminous Flux 100% 25 0.003 Warm White 94% 91% -0.006 -0.009 88% Warm White -0.012 85% -0.015 82% 0 25 50 75 100 Neutral White Cool White 25°C Pulsed 125 Case Temperature (°C) Case Temperature (°C) Figure 10: 2000K, 65 CRI Color Shift vs. Case Temperature Figure 9: Typical DC ccx Shift vs. Case Temperature 0.4101 0 25 50 75 100 0.41 125 0.000 0.4099 0.4098 -0.002 Pulsed Center Point Tc=25°C 15°C 25°C 0.4097 ccy ccx Shift -0.004 -0.006 65°C 0.4093 Warm White -0.012 0.4095 0.4094 -0.008 -0.010 45°C 0.4096 Neutral White 85°C 0.4092 Cool White 25°C Pulsed 105°C 0.4091 Case Temperature (°C) 0.409 0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532 ccx Notes for Figures 7 - 9: 1. Characteristics shown for warm white based on 3000K and 80 CRI. 2. Characteristics shown for neutral white based on 4000K and 80 CRI. 3. Characteristics shown for cool white based on 5000K and 70 CRI. 4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information. 23 Performance Curves Figure 11: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 12: 3000K, 97 CRI Color Shift vs. Case Temperature1 0.4110 0.4050 15°C Pulsed Center Point Tc = 25°C 0.4100 25°C 25°C 0.4090 45°C 0.4010 45°C ccy ccy 0.4080 Pulsed Center Point Tc = 25°C 15°C 0.4030 0.4070 65°C 70°C 0.3990 0.4060 85°C 85°C 0.4050 0.3970 105°C 0.4040 105°C 0.4030 0.457 0.3950 0.4323 0.4572 0.4574 0.4576 0.4578 0.4328 0.4333 0.458 Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature3 Pulsed Center Point Tc=25°C 25°C 15°C 0.368 25°C 0.401 0.367 0.4 0.366 45°C ccy ccy 0.369 15°C 0.399 0.4343 65°C 0.398 0.397 0.4353 Pulsed Center Point Tc=25°C 45°C 0.365 0.364 70°C 0.363 85°C 0.4348 Figure 14: 3000K Class A Color Shift vs. Case Temperature1 0.403 0.402 0.4338 ccx ccx 85°C 0.362 105°C 0.396 0.395 0.444 0.361 0.4445 0.445 0.4455 0.446 0.4465 0.447 105°C 0.36 0.416 0.4165 0.417 ccx Figure 15: 3500K Class A Color Shift vs. Case Temperature1 ccx 0.4175 0.418 0.4185 Figure 16: 4000K Class A Color Shift vs. Case Temperature1 0.37 15°C 0.368 25°C 15°C 0.3740 25°C 0.3720 45°C 45°C 0.3700 0.364 70°C 0.362 0.3680 85°C 70°C 0.3660 0.36 85°C 0.3640 105°C 0.358 0.392 Pulsed Center Point Tc=25°C ccy ccy 0.366 0.3760 Pulsed Center Point Tc=25°C 105°C 0.393 0.394 0.395 0.396 0.397 ccx Note for Figures 10-16: 1. Measurements made under DC test conditions at the nominal drive current. 2. Typical color shift is shown with a tolerance of ±0.002. 3. Characteristics shown for Decor Series Showcase products, BXRC-30G100C-x-73 0.3620 0.373 0.374 0.375 0.376 ccx 0.377 0.378 0.379 24 Typical Radiation Pattern Figure 17: Typical Spatial Radiation Pattern Note for Figure 17: 1. Typical viewing angle is 120⁰. 2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value. Figure 18: Typical Polar Radiation Pattern 25 Typical Color Spectrum Figure 19: Typical Color Spectrum 110% 3000K 100% 4000K 5000K Relative Spectral Power Distribution 90% 6500K 80% 70% 60% 50% 40% 30% 20% 10% 0% 400 450 500 550 600 650 700 750 800 Wavelength (nm) Note for Figure 19: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 2. Color spectra shown is 3000K and 80 CRI. 3. Color spectra shown is 4000K and 80 CRI. 4. Color spectra shown is 5000K and 70 CRI. 4. Color spectra shown is 6500K and 70 CRI. Figure 20: Typical Color Spectrum for Vero 10 with Décor Series 1 20B 27H 0.9 30G (Décor Series Showcase) 30H Relative Spectral Power Distribution 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 400 450 500 550 600 Wavelength (nm) 650 700 750 800 Note for Figure 20: 1. Color spectra measured at nominal current for Tj = Tc = 25°C. 26 Mechanical Dimensions Figure 21: Drawing for Vero 10 LED Array Notes for Figure 21: 1. Drawings are not to scale. 2. Dimensions are in mm. 3. Unless otherwise specified, tolerances are ± 0.10mm. 4. Mounting slots (2X) are for M2.5 screws. 5. Bridgelux recommends two tapped holes for mounting screws with 19.0 ± 0.10mm center-to-center spacing. 6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat, countersink, or raised head screws. 7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively. 8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used depending on application specific design requirements. 9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations. 10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm. 11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array. 27 Color Binning Information Figure 22: Warm and Neutral White Test Bins in xy Color Figure 23: Graph of Cool White Test Bins in xy Color Space Space 0.44 0.39 4 SDCM 3 SDCM 2000K 3SDCM 2 SDCM 0.42 2700K 0.37 3000K 5000K 0.36 3500K 0.4 3 SDCM 0.38 5700K 0.35 Y Y 4000K 0.34 0.38 6500K 0.33 0.36 0.32 0.31 0.34 0.36 0.39 0.42 0.45 X 0.48 0.51 0.54 0.3 0.3 0.31 0.32 0.33 0.34 0.35 0.36 X Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT Bin Code 2000K 2700K 3000K1 3500K1 4000K1 ANSI Bin (for reference only) - (2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K) 73 (3 SDCM) - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K) 72 (2 SDCM) - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K) Center Point (x,y) (0.5280, 0.4100) (0.4578, 0.4101) (0.4338, 0.403) (0.4465, 0.4024)2 (0.4073, 0.3917) (0.3818, 0.3797) Note for Table 8: 1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information. 2. Center Point for Decor Series Showcase. Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C) Bin Code 5000K 5700K 6500K ANSI Bin (for reference only) (4745K - 5311K) (5312K - 6022K) (6022K - 7042K) 74 (4 SDCM) (4801K - 5282K) (5481K - 5829K) (6270K - 6765K) 73 (3 SDCM) (4835K-5215K) (5490K-5820K) (6250K-6745K) Center Point (x,y) (0.3447, 0.3553) (0.3287, 0.3417) (0.3123, 0.3282) 28 Packaging and Labeling Figure 24: Drawing for Vero 10 Packaging Tray Notes for Figure 24: 1. Dimensions are in millimeters. 2. Drawings are not to scale. 29 Packaging and Labeling Figure 25: Vero Series Packaging and Labeling Notes for Figure 25: 1. Each tray holds 200 COBs. 2. Each tray is vacuum sealed in an anti-static bag and placed in its own box. 3. Each tray, bag and box is to be labeled as shown above. Figure 26: Gen. 7 Product Labeling Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux manufacturing use only. The image below shows which markings are for customer use and which ones are for Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice, however these will not impact the form, function or performance of the COB array. Customer Use- 2D Barcode Scannable barcode provides product part number and other Bridgelux internal production information. Customer Use- Product part number 30E1000C 73 2F Customer Use- Vf Bin Code included to enable greater luminaire design flexibility. Refer to AN92 for bin code definitions. 30 Design Resources Application Notes 3D CAD Models Bridgelux has developed a comprehensive set of application notes and design resources to assist customers in successfully designing with the Vero product family of LED array products. For all available application notes visit www.bridgelux.com. Three dimensional CAD models depicting the product outline of all Bridgelux Vero LED arrays are available in both IGS and STEP formats. Please contact your Bridgelux sales representative for assistance. Optical Source Models LM80 Optical source models and ray set files are available for all Bridgelux products. For a list of available formats, visit www.bridgelux.com. LM80 testing has been completed and the LM80 report is now available. Please contact your Bridgelux sales representative for LM-80 report. Precautions CAUTION: CHEMICAL EXPOSURE HAZARD Exposure to some chemicals commonly used in luminaire manufacturing and assembly can cause damage to the LED array. Please consult Bridgelux Application Note AN31 for additional information. CAUTION: RISK OF BURN Do not touch the Vero LED array during operation. Allow the array to cool for a sufficient period of time before handling. The Vero LED array may reach elevated temperatures such that could burn skin when touched. CAUTION CONTACT WITH LIGHT EMITTING SURFACE (LES) Avoid any contact with the LES. Do not touch the LES of the LED array or apply stress to the LES (yellow phosphor resin area). Contact may cause damage to the LED array. Optics and reflectors must not be mounted in contact with the LES (yellow phosphor resin area). Optical devices may be mounted on the top surface of the plastic housing of the Vero LED array. Use the mechanical features of the LED array housing, edges and/or mounting holes to locate and secure optical devices as needed. Disclaimers MINOR PRODUCT CHANGE POLICY STANDARD TEST CONDITIONS The rigorous qualification testing on products offered by Bridgelux provides performance assurance. Slight cosmetic changes that do not affect form, fit, or function may occur as Bridgelux continues product optimization. Unless otherwise stated, array testing is performed at the nominal drive current. 31 About Bridgelux: Bridging Light and Life™ At Bridgelux, we help companies, industries and people experience the power and possibility of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient, cost effective and easy to integrate. Our focus is on light’s impact on human behavior, delivering products that create better environments, experiences and returns—both experiential and financial. And our patented technology drives new platforms for commercial and industrial luminaires. For more information about the company, please visit bridgelux.com twitter.com/Bridgelux facebook.com/Bridgelux youtube.com/user/Bridgelux linkedin.com/company/bridgelux-inc-_2 WeChat ID: BridgeluxInChina 46430 Fremont Boulevard Fremont, CA 94538 U.S.A. Tel (925) 583-8400 www.bridgelux.com © 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero, V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners. Bridgelux Gen 7 Vero 10 Array Series Product Data Sheet DS90 Rev. N (11/2018) 32
BXRC-27E1000-D-72 价格&库存

很抱歉,暂时无法提供与“BXRC-27E1000-D-72”相匹配的价格&库存,您可以联系我们找货

免费人工找货